SIMATIC

Nikola_plc/SIMATIC 300(1)

01/31/2012 07:32:44 PM

SIMATIC 300(1) UR - Rack (0)


Short description: Order no.: Designation: UR 6ES7 390-1???0-0AA0 UR

Rack (0), Slot 2


Short description: Order no.: Designation: Width: MPI address: Highest MPI address: Baud rate: Comment: - - Startup Startup when expected/actual config. differ: Hardware test at warm restart: Startup after Power On: Monitoring time for "Finished" message by means of modules: Transfer of the parameters to modules: Scan cycle Scan cycle monitoring time: Scan cycle load from Communication: Clock memory: Retentivity Number of memory bytes starting at MB0: Number of S7 timers starting at T0: Number of S7 counters starting at C0: Retentive area 1 DB no.: Byte address: Number of bytes: Retentive area 2 DB no.: Byte address: Number of bytes: Retentive area 3 DB no.: Byte address: Number of bytes: Retentive area 4 DB no.: Byte address: Number of bytes: Retentive area 5 DB no.: Byte address: Number of bytes: Retentive area 6 DB no.: CPU 315-2 DP 6ES7 315-2AF00-0AB0 CPU 315-2 DP 1 2 31 187.5 Kbps

Yes No Warm Restart 65000 ms 10000 ms 150 ms 20 % No 16 0 8 1 0 0 1 0 0 1 0 0 1 0 0 1 0 0 1

Page 1 of 5

SIMATIC
Byte address: Number of bytes: Retentive area 7 DB no.: Byte address: Number of bytes: Retentive area 8 DB no.: Byte address: Number of bytes: Hardware interrupts OB40 - Priority: Time-delay interrupts OB20 - Priority: Asynchronous error interrupts OB81 - Priority: OB82 - Priority: OB85 - Priority: OB86 - Priority: OB87 - Priority: Time-of-day interrupts OB10 Priority: Active: Execution: Start date: Start time: Cyclic interrupts OB35 Priority: Execution: System diagnostics Expanded functional scope: Report cause of STOP: Clock Synchronization in the PLC Synchronization type: Time interval: Correction factor:

Nikola_plc/SIMATIC 300(1)
0 0 1 0 0 1 0 0 16 3 26 26 26 26 26

01/31/2012 07:32:44 PM

2 No None 01/01/1994 00:00

12 100 ms No Yes

None None 0 ms

Communication Connection Resources Reserved for PG communication: 1 OP communication: 1 Max. Number of connection 4 resources:

Rack (0), Slot 2, Interface X2


Short description: Order no.: Designation: Width: PROFIBUS address: Highest PROFIBUS address: Baud rate: Comment: - - Addresses Inputs Start: End: DP - - DP 1 2 126 1.5 Mbps

1023 1023

Page 2 of 5

SIMATIC

Nikola_plc/SIMATIC 300(1)

01/31/2012 07:32:44 PM

Rack (0), Slot 4


Short description: Order no.: Designation: Digital channels: Width: Comment: - - Addresses Inputs Start: End: DI16xDC24V 6ES7 321-1BH82-0AA0 DI16xDC24V 16 Inputs 1

0 1

Rack (0), Slot 5


Short description: Order no.: Designation: Digital channels: Width: Comment: - - Addresses Outputs Start: End: DO16xDC24V/0.5A 6ES7 322-1BH81-0AA0 DO16xDC24V/0.5A 16 Outputs 1

0 1

Rack (0), Slot 6


Short description: Order no.: Designation: Analog channels: Width: Comment: - - Addresses Inputs Start: End: Parameters Basic settings Enable for interrupt at Limit exceeded: Diagnostics: Input 0 - 1 Diagnostic interrupt Group diagnostics: Wire break: Measuring Measuring type: Measuring range: Integration time: Limit alarm at high limit: low limit: AI2x12Bit 6ES7 331-7KB00-0AB0 AI2x12Bit 2 Inputs 1

256 259

No No

No No current (2-wire transducer) 4..20 mA 50 Hz - - - - -

DP master system:
Assigned master: Short description Order no. Designation Location DP DP

Page 3 of 5

SIMATIC
Station Rack Slot Receptacle for interface module PROFIBUS address

Nikola_plc/SIMATIC 300(1)
SIMATIC 300(1) 0 2 1 2

01/31/2012 07:32:44 PM

Group: 1 Comment: The group supports SYNC. The group supports FREEZE. Group: 2 Comment: The group supports SYNC. The group supports FREEZE. Group: 3 Comment: The group supports SYNC. The group supports FREEZE. Group: 4 Comment: The group supports SYNC. The group supports FREEZE. Group: 5 Comment: The group supports SYNC. The group supports FREEZE. Group: 6 Comment: The group supports SYNC. The group supports FREEZE. Group: 7 Comment: The group supports SYNC. The group supports FREEZE. Group: 8 Comment: The group supports SYNC. The group supports FREEZE.

Address Overview
Addresses of: Address area from: Address area to: CPU 315-2 DP 0 1023

Page 4 of 5

SIMATIC
Available address assignment: Rack / Slot:
Module DI16xDC24V AI2x12Bit DP DO16xDC24V/0.5A Addr. from 0 256 1023 0

Nikola_plc/SIMATIC 300(1)
Yes 0/2
Addr. to 1 259 1023 1 Type I I E* O PIP OB1 PI ---OB1 PI DP PN R 0 0 0 0 S 4 6 2 5 IF 1 -

01/31/2012 07:32:44 PM

Page 5 of 5

SIMATIC

Nikola_plc\ SIMATIC 300(1)\CPU 315-2 DP\...\OB1 - <offline>

01/31/2012 07:22:00 PM

OB1 - <offline>
"" Name: Author: Family: Version: 0.1 Block version: 2 Time stamp Code: 01/27/2012 07:48:41 AM Interface: 02/15/1996 04:51:12 PM Lengths (block/logic/data): 00508 00376 00026

Name TEMP OB1_EV_CLASS OB1_SCAN_1 OB1_PRIORITY OB1_OB_NUMBR OB1_RESERVED_1 OB1_RESERVED_2 OB1_PREV_CYCLE OB1_MIN_CYCLE OB1_MAX_CYCLE OB1_DATE_TIME

Data Type

Address 0.0

Comment

Byte Byte Byte Byte Byte Byte Int Int Int

0.0 1.0 2.0 3.0 4.0 5.0 6.0 8.0 10.0

Bits 0-3 = 1 (Coming event), Bits 4-7 = 1 (Event class 1) 1 (Cold restart scan 1 of OB 1), 3 (Scan 2-n of OB 1) Priority of OB Execution 1 (Organization block 1, OB1) Reserved for system Reserved for system Cycle time of previous OB1 scan (milliseconds) Minimum cycle time of OB1 (milliseconds) Maximum cycle time of OB1 (milliseconds) Date and time OB1 started

Date_And_Time 12.0

Block: OB1

"Main Program Sweep (Cycle)"

Network: 1

DB1 "Citanje temperatur e" EN ENO

Network: 2

DB3 "Kvasenje automobila " EN ENO

Page 1 of 3

SIMATIC

Nikola_plc\ SIMATIC 300(1)\CPU 315-2 DP\...\OB1 - <offline>

01/31/2012 07:22:00 PM

Network: 3

DB4 "Sapunjanj e automobila " EN ENO

Network: 4

DB5 "Ispiranje automobil a" EN ENO

Network: 5

DB6 "Susenje automobila " EN ENO

Network: 6

DB7 "Voskiranj e automobila " EN ENO

Network: 7

DB8 "Susenje nakon voskiranja " EN ENO

Page 2 of 3

SIMATIC

Nikola_plc\ SIMATIC 300(1)\CPU 315-2 DP\...\OB1 - <offline>

01/31/2012 07:22:00 PM

Network: 8

DB2 "Kontrola motora" EN ENO

Network: 9

DB9 "Aktuatori " EN ENO

Network: 10

DB10 "Nivo i temp sapunice" EN ENO

Network: 11

DB11 "Nivo voska" EN ENO

Page 3 of 3

SIMATIC

Nikola_plc\ SIMATIC 300(1)\CPU 315-2 DP\...\FB1 - <offline>

01/31/2012 07:22:18 PM

FB1 - <offline>
"Citanje temperature" Name: Author: Family: Version: 0.1 Block version: 2 Time stamp Code: 01/27/2012 05:47:11 AM Interface: 01/27/2012 05:29:40 AM Lengths (block/logic/data): 00170 00078 00014

Name IN OUT IN_OUT STAT TEMP

Data Type

Address 0.0 0.0 0.0 0.0 0.0

Initial Value

Comment

Block: FB1 Ocitavanja senzora temperature

Network: 1

"SCALE" EN PIW256 IN 1.500000e+ 002 HI_LIM 0.000000e+ 000 LO_LIM "Unipolarn o" BIPOLAR ENO RET_VAL MW100 OUT MD102

Page 1 of 1

SIMATIC

Nikola_plc\ SIMATIC 300(1)\CPU 315-2 DP\...\FB2 - <offline>

01/31/2012 07:22:20 PM

FB2 - <offline>
"Kontrola motora" Name: Author: Family: Version: 0.1 Block version: 2 Time stamp Code: 01/27/2012 07:39:41 AM Interface: 01/27/2012 05:47:32 AM Lengths (block/logic/data): 00146 00046 00002

Name IN OUT IN_OUT STAT TEMP

Data Type

Address 0.0 0.0 0.0 0.0 0.0

Initial Value

Comment

Block: FB2 Kontrola motora

Network: 1 Startovanje motora Start tastera "Start" EN W#16#0 IN EN B#16#0 IN

MOVE ENO OUT MW0 MOVE ENO OUT MB2

Network: 2

"Start"

"Motor_ run" S

Network: 3 Zaustavljanje motora "Motor_ run" R

"Stop"

Page 1 of 1

SIMATIC

Nikola_plc\ SIMATIC 300(1)\CPU 315-2 DP\...\FB3 - <offline>

01/31/2012 07:22:21 PM

FB3 - <offline>
"Kvasenje automobila" Name: Author: Family: Version: 0.1 Block version: 2 Time stamp Code: 01/27/2012 06:41:15 AM Interface: 01/27/2012 05:54:13 AM Lengths (block/logic/data): 00138 00042 00000

Name IN OUT IN_OUT STAT TEMP

Data Type

Address 0.0 0.0 0.0 0.0 0.0

Initial Value

Comment

Block: FB3 Postupak kvasenja automobila u trajanju od 20s

Network: 1 Kvasenje automobila "Foto_ kvasi" "Tajmer_ kvasi" "Kvasi_ done" "Motor_ run" R "Kvasi_ run" S

Network: 2

"Kvasi_ run" S S5T#20S TV "Start" R

T1 S_ODT Q BI BCD

"Tajmer_ kvasi" S

Page 1 of 2

SIMATIC

Nikola_plc\ SIMATIC 300(1)\CPU 315-2 DP\...\FB3 - <offline>

01/31/2012 07:22:21 PM

Network: 3

"Tajmer_ kvasi"

"Kvasi_ done"

"Motor_ run" S "Kvasi_ run" R "Kvasi_ done" S

Page 2 of 2

SIMATIC

Nikola_plc\ SIMATIC 300(1)\CPU 315-2 DP\...\FB4 - <offline>

01/31/2012 07:22:22 PM

FB4 - <offline>
"Sapunjanje automobila" Name: Author: Family: Version: 0.1 Block version: 2 Time stamp Code: 01/27/2012 06:40:27 AM Interface: 01/27/2012 06:12:26 AM Lengths (block/logic/data): 00138 00042 00000

Name IN OUT IN_OUT STAT TEMP

Data Type

Address 0.0 0.0 0.0 0.0 0.0

Initial Value

Comment

Block: FB4 Proces sapunjanja automobila u trajanju od 15s

Network: 1 Sapunjanje automobila "Tajmer_ sap" "Motor_ run" R "Sapunjanj e_run" S

"Foto_sap"

"Sap_done"

Network: 2

"Sapunjanj e_run" S S5T#15S TV "Start" R

T2 S_ODT Q BI BCD

"Tajmer_ sap" S

Page 1 of 2

SIMATIC

Nikola_plc\ SIMATIC 300(1)\CPU 315-2 DP\...\FB4 - <offline>

01/31/2012 07:22:22 PM

Network: 3

"Tajmer_ sap"

"Sap_done"

"Motor_ run" S "Sapunjanj e_run" R "Sap_done" S

Page 2 of 2

SIMATIC

Nikola_plc\ SIMATIC 300(1)\CPU 315-2 DP\...\FB5 - <offline>

01/31/2012 07:22:23 PM

FB5 - <offline>
"Ispiranje automobila" Name: Author: Family: Version: 0.1 Block version: 2 Time stamp Code: 01/27/2012 06:58:56 AM Interface: 01/27/2012 06:45:06 AM Lengths (block/logic/data): 00138 00042 00000

Name IN OUT IN_OUT STAT TEMP

Data Type

Address 0.0 0.0 0.0 0.0 0.0

Initial Value

Comment

Block: FB5 Ispiranje automobila u trajanju od 15s

Network: 1 Ispiranje automobila "Tajmer_ "Foto_isp" ispiranje" "Motor_ run" R "Ispiranje _run" S

"Isp_done"

Network: 2

"Ispiranje _run" S S5T#15S TV "Start" R

T3 S_ODT Q BI BCD

"Tajmer_ ispiranje" S

Page 1 of 2

SIMATIC

Nikola_plc\ SIMATIC 300(1)\CPU 315-2 DP\...\FB5 - <offline>

01/31/2012 07:22:23 PM

Network: 3

"Tajmer_ ispiranje"

"Isp_done"

"Motor_ run" S "Ispiranje _run" R "Isp_done" S

Page 2 of 2

SIMATIC

Nikola_plc\ SIMATIC 300(1)\CPU 315-2 DP\...\FB6 - <offline>

01/31/2012 07:22:24 PM

FB6 - <offline>
"Susenje automobila" Name: Author: Family: Version: 0.1 Block version: 2 Time stamp Code: 01/27/2012 07:55:12 AM Interface: 01/27/2012 06:59:06 AM Lengths (block/logic/data): 00138 00042 00000

Name IN OUT IN_OUT STAT TEMP

Data Type

Address 0.0 0.0 0.0 0.0 0.0

Initial Value

Comment

Block: FB6 Susenje automobila u trajanju od 15s

Network: 1 Susenje automobial "Foto_ susi1" "Tajmer_ susi1" "Susi1_ done" "Motor_ run" R "Susi1_ run" S

Network: 2

"Susi1_ run" S S5T#15S TV "Start" R

T4 S_ODT Q BI BCD

"Tajmer_ susi1" S

Page 1 of 2

SIMATIC

Nikola_plc\ SIMATIC 300(1)\CPU 315-2 DP\...\FB6 - <offline>

01/31/2012 07:22:24 PM

Network: 3

"Tajmer_ susi1"

"Susi1_ done"

"Motor_ run" S "Susi1_ run" R "Susi1_ done" S

Page 2 of 2

SIMATIC

Nikola_plc\ SIMATIC 300(1)\CPU 315-2 DP\...\FB7 - <offline>

01/31/2012 07:22:25 PM

FB7 - <offline>
"Voskiranje automobila" Name: Author: Family: Version: 0.1 Block version: 2 Time stamp Code: 01/27/2012 07:08:23 AM Interface: 01/27/2012 07:03:24 AM Lengths (block/logic/data): 00138 00042 00000

Name IN OUT IN_OUT STAT TEMP

Data Type

Address 0.0 0.0 0.0 0.0 0.0

Initial Value

Comment

Block: FB7 Voskiranje automobila u trajanju od 30s

Network: 1 Voskiranje automobila "Foto_ vosak" "Tajmer_ vosak" "Vosak_ done" "Motor_ run" R "Vosak_ run" S

Network: 2

"Vosak_ run" S S5T#30S TV "Start" R

T5 S_ODT Q BI BCD

"Tajmer_ vosak" S

Page 1 of 2

SIMATIC

Nikola_plc\ SIMATIC 300(1)\CPU 315-2 DP\...\FB7 - <offline>

01/31/2012 07:22:25 PM

Network: 3

"Tajmer_ vosak"

"Vosak_ done"

"Motor_ run" S "Vosak_ run" R "Vosak_ done" S

Page 2 of 2

SIMATIC

Nikola_plc\ SIMATIC 300(1)\CPU 315-2 DP\...\FB8 - <offline>

01/31/2012 07:22:26 PM

FB8 - <offline>
"Susenje nakon voskiranja" Name: Family: Author: Version: 0.1 Block version: 2 Time stamp Code: 01/27/2012 07:13:01 AM Interface: 01/27/2012 07:08:32 AM Lengths (block/logic/data): 00138 00042 00000

Name IN OUT IN_OUT STAT TEMP

Data Type

Address 0.0 0.0 0.0 0.0 0.0

Initial Value

Comment

Block: FB8 Susenje automobila nakon voskiranja u trajanju od 25s

Network: 1 Susenje automobila "Foto_ susi2" "Tajmer_ susi2" "Susi2_ done" "Motor_ run" R "Susi2_ run" S

Network: 2

"Susi2_ run" S S5T#25S TV "Start" R

T6 S_ODT Q BI BCD

"Tajmer_ susi2" S

Page 1 of 2

SIMATIC

Nikola_plc\ SIMATIC 300(1)\CPU 315-2 DP\...\FB8 - <offline>

01/31/2012 07:22:26 PM

Network: 3

"Tajmer_ susi2"

"Susi2_ done"

"Motor_ run" S "Susi2_ run" R "Susi2_ done" S

Page 2 of 2

SIMATIC

Nikola_plc\ SIMATIC 300(1)\CPU 315-2 DP\...\FB9 - <offline>

01/31/2012 07:22:27 PM

FB9 - <offline>
"Aktuatori" Name: Author: Family: Version: 0.1 Block version: 2 Time stamp Code: 01/27/2012 07:30:46 AM Interface: 01/27/2012 07:23:11 AM Lengths (block/logic/data): 00136 00030 00000

Name IN OUT IN_OUT STAT TEMP

Data Type

Address 0.0 0.0 0.0 0.0 0.0

Initial Value

Comment

Block: FB9 Pogonjenje izlaza

Network: 1

"Motor_ run"

"Motor"

Network: 2

"Kvasi_ run"

"Kvasi"

Network: 3

"Sapunjanj e_run"

"Sap"

Network: 4

"Ispiranje _run"

"Isp"

Page 1 of 2

SIMATIC

Nikola_plc\ SIMATIC 300(1)\CPU 315-2 DP\...\FB9 - <offline>

01/31/2012 07:22:27 PM

Network: 5

"Susi1_ run"

"Susi1"

Network: 6

"Vosak_ run"

"Vosak"

Network: 7

"Susi2_ run"

"Susi2"

Network: 8

Page 2 of 2

SIMATIC

Nikola_plc\ SIMATIC 300(1)\CPU 315-2 DP\...\FB10 - <offline>

01/31/2012 07:22:28 PM

FB10 - <offline>
"Nivo i temp sapunice" Name: Author: Family: Version: 0.1 Block version: 2 Time stamp Code: 01/27/2012 07:44:50 AM Interface: 01/27/2012 07:39:54 AM Lengths (block/logic/data): 00118 00022 00000

Name IN OUT IN_OUT STAT TEMP

Data Type

Address 0.0 0.0 0.0 0.0 0.0

Initial Value

Comment

Block: FB10

Network: 1

"Sap_min"

"Puni_sap" S

Network: 2

"Sap_max"

"Puni_sap" R

Network: 3

CMP <R MD102 IN1 5.000000e+ 001 IN2

"Grejac"

Page 1 of 1

SIMATIC

Nikola_plc\ SIMATIC 300(1)\CPU 315-2 DP\...\FB11 - <offline>

01/31/2012 07:22:29 PM

FB11 - <offline>
"Nivo voska" Name: Author: Family: Version: 0.1 Block version: 2 Time stamp Code: 01/27/2012 07:46:51 AM Interface: 01/27/2012 07:45:15 AM Lengths (block/logic/data): 00104 00010 00000

Name IN OUT IN_OUT STAT TEMP

Data Type

Address 0.0 0.0 0.0 0.0 0.0

Initial Value

Comment

Block: FB11

Network: 1

"Vosak_ min"

"Puni_ vosak" S

Network: 2

"Vosak_ max"

"Puni_ vosak" R

Page 1 of 1