Você está na página 1de 3

Appendix _____

Heat exchanger in MDEA unit

Thi Tho Tci Tco

= 100 C = 70 C = 60 C = 80 C

(T)lm = = 14.49 C

= = 1.5

= = 0.5

Ft =

1.0 Tm = Ft Tlm = 14.49 C = 50 W/m2.K

= 32 kW

= = 2.225 m2

Tube dimensions: Outlet diameter, OD Inlet diameter, ID Length, L = = = 19.05 mm 13.51 m 4.88 m 5 m

Area of one tube

= =

DL 0.299 m2

Number of tubes, Nt

= = 8 tubes

As the shell-side fluid is relatively clean, use 1.25 triangular pitch. Bundle diameter, DB = = 106. 2377 mm

do N1 & K1

= =

Diameter outside tube Constant

Use a pull-through floating head. Shell-bundle clearance = 53

Shell diameter, DS

= =

DB + Shell bundle clearance 159.2377 mm

Tube cross-sectional area

= = 143.35 mm2

Total flow area

= =

Tube per pass Tube cross-sectional area 1.1468 10-3 m2

Baffle spacing, IB

= = 31 mm

Tube pitch, Pt

= =

1.25 do 23.81 mm

Cross-flow area, As

= = 986.859 mm2