Septage facility shall be limited to 30 m3/ day for the initial phases to be expanded later Dilution and mixing

tank Let one tanker size be 4 m3 Assume 8 such tankers during a day to be treated during non-peak hours

Assume a tank of size of holding capacity of 16 m3 with a dilution rate of 1:4

Dilution water intake and pipe: Dilution water intake and pipe: Dilution water shall be fed from the effluent channel with a depressed bottom and on intake channel of site at the tapping point. Water shall flow by gravity through a pipe of suitable diameter in PVC 10 Kg to the retaining tank of 16 m3. The approximate length of pipe shall be 100m.

Septage receiving tank Liquid capacity = 16 m3 Liquid depth = 2.50m F.B = 1 M Area = 6.4 m2 Diameter = 2.85m Perimeter 3m Provide tank size 3000 x 3500 Deep Initially 1 no tank will be provided

A standby shall be provided Pump set for dilution water From the intake pump of effluent water will be simultaneously pumped into intake plant for further dilution to dilute the septage further by 22 times. Since the head and duration remain the same pump size shall be

1.28 x 22 x 1.30 = 36.60 HP Use 40 HP pumpset (1S +1W)