FOUNDATIONBOLTLENGTHCALCULATION

InputData:
SteeltoCementconcretebondstrength=9Kg/cm^2(ForconcretegradeM25)
Bearingpressureonconcrete=40Kg/cm^2
Sizeofbearingplate=125x125mm
ForM30Bolt:
Upliftforce=40500Kg.
No.bolts=8
Upliftforceperbolt(F)=5062.5Kg.
Lengthofbolt(P)=

P=
P=
P=
P

(StaadoutputforPDDESP)

Upliftforceperbolt(Areaofbearingplatexbearingpressure)
xdia.ofboltxsteeltoconcretebondstrength
(5062.5(12.5^2pi/4x3^2)x40)
pix3x9
10.666cm
(Bycalculation)
106.66mm
110mm

Requiredlengthofbolt=P+B
(ReferPage2of2)
=110+140(max.baseplatethk.75mm+Nut&washer65mm)
=250mm
GivenboltLength=500mm
250mm<500mm
Hence,Thegivenlengthisok.
ForM36Bolt:
Upliftforce=72000Kg.
No.bolts=8
Upliftforceperbolt(F)=9000Kg.
Lengthofbolt(L)=

P=
P=
P=
P

(StaadoutputforPDDESP)

Upliftforceperbolt(Areaofbearingplatexbearingpressure)
xdia.ofboltxsteeltoconcretebondstrength
(9000(12.5^2pi/4x3.6^2)x40)
pix3.6x9
31.006cm
(Bycalculation)
310.06mm
315mm

Requiredlengthofbolt=P+B
(ReferPage2of2)
=315+160(max.baseplatethk.75mm+Nut&washer85mm)
=475mm
GivenboltLength=950mm
475mm<950mm
Hence,Thegivenlengthisok.