Você está na página 1de 1

Wind load calculation: Tank OD Height of the tank Lever arm Distance between C.G.

of tank and base plate Design wind speed Probability factor Terrain, height and structure factor Topography factor Calculation: Design wind speed Intensity of pressure

Do h B l Vb k1 k2 k3

= = = = = = = =

2.532 6.2 1.8

m m m 7m 39 m/s 1.06 1 (Category-2, Class-A) 1

Vz = pz = pz = = Cf =

41.34 m/s 1025.4 N/m2 1.05 kN/m2 2.44866

Height / breadth ratio Force co-efficient for circular section