Você está na página 1de 10

VIKING HEAVY DUTY PUMPS

SERIES 4195 STANDARD CONSTRUCTION FEATURES

Section Page Issue

144 144.1 D

Pressure Range Temperature Range Viscosity Range

250 PSI (17 BAR) for 100 SSU (20 cSt) and above 150 PSI (10 BAR) for 38 to 100 SSU (3 cSt to 20 cSt) 100 PSI (7 BAR) for below 38 SSU (3 cSt) - 40 F. to + 350F. (- 40 C. to + 177C.) 28 SSU to 15,000 SSU (0.1 cP to 3,300 cSt)

SERIES 4195 Pumps


Cutaway View AS, AK, AL

SERIES 4195 Pumps


Cutaway View G, GG, H, HJ, HL

GPM up to 75 (M/Hr up to 17)


(Nominal Rating)

(Standard Equipment) Pumps are equipped with inner casing ball bearing installed outside of mechanical seal and a radial thrust ball bearing permitting heavy-duty service up to 250 PSI (17 BAR). Bearings are Sealed for Life.

BALL BEARINGS

(Standard Equipment) (AS, AK, AL Sizes) Internal pumping gears (rotor and idler) are constructed of ductile iron for added strength in handling all types of liquids up to 15,000 SSU (3,300 cSt). HL size rotor also furnished in ductile iron.

DUCTILE IRON PARTS

(Standard Equipment) (AS, AK, AL Sizes) A patented pressure lubrication system automatically lubricates the idler bushing. This system provides a constant film of liquid between the idler bushing and idler pin at a pressure equal to the pump discharge pressure regardless of pump rotation.

PRESSURE LUBRICATION

(Standard Equipment) O-Ring gaskets are used between casing and head plate and between casing and relief valve or valve plates. Flat valve gaskets furnished on G, GG, H, HJ and HL size pumps. These gaskets provide a positive seal eliminating a chance for leakage at these points.

O-RING GASKETS

Vikings high-speed, heavy-duty Series 4195 pumps are available in capacities up to 75 GPM. These pumps can be furnished directly connected to a 50 Hz or 60 Hz motor. (See Series 4195D units shown on page 144.3.) All eight sizes of Viking Series 4195 pumps are furnished with single mechanical seals. This seal is a simple selfadjusting, non-leak method of shaft sealing located ahead of the casing ball bearing. The Series 4195 pumps are built for continuous or intermittent duty for such applications as filtering, circulating, transferring, or booster service in general industrial, petroleum and marine uses. NOTE: UL listed pumps for handling flammable liquids require special construction. Externals are high strength cast iron. (Ductile Iron Casing on AS, AK and AL sizes). See Catalog Section 440 for details and pricing information. Model numbers for these pumps must be designated by a suffix -F, eg. GG4195-F or when used with a D drive, GG4195D-F. UL listed models must be equipped with either an internal or return-to-tank safety relief valve. Maximum discharge pressure for UL listed models is 125 PSIG.
Values shown represent minimums or maximums. Some special construction or
consideration may be required before a cataloged pump can be applied to an application involving maximum pressure or minimum or maximum temperature and/or viscosity. Certain models have restrictions in pressures and/or viscosities. See specifications, page 144.2, and performance curves.

Nominal capacities based on handling thin liquids.


Metric conversions are based on US measurements and rounded to the nearest whole number.

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2009

Section Page Issue

144 144.2 D

VIKING HEAVY DUTY PUMPS


SERIES 4195 STANDARD CONSTRUCTION UNMOUNTED PUMPS
MECHANICAL SEAL Buna-N bellows. Buna-N O-ring. Carbon rotating face (washer). Ni-Resist stationary seat. Steel metal parts. Stainless steel spring.

G, GG, H, HJ and HL Sizes

SERIES 4195 Pumps

In addition to the famous features listed on the previous page, Series 4195 heavy-duty pumps are furnished with an integral relief valve as shown in the pump photos above. Return-to-tank valves are also available on all models on request. Note: On the G, GG, H, HJ and HL sizes, the valve mounts on the pump head. The AS, AK and AL size value mounts on top of the pump casing. All sizes equipped with Buna-N mechanical seal with carbon rotating and Ni-Resist stationary faces.
Standard Construction Models G4195 , GG4195 H4195 , HJ4195 HL4195 AS4195 , AK4195 , AL4195 Casing Iron Iron Iron Head Iron Iron Iron Rotor Idler

SERIES 4195 Pumps


AS, AK and AL Sizes

Dimensions for Unmounted PumpsSee Page 144.6. Performance Data for Unmounted PumpsSee Pages 144.13 through 144.26.

CONSTRUCTION SERIES 4195 (GG THROUGH AL SIZES)


Rotor Shaft and Idler Pin Steel Steel Steel Idler Bushing Carbon Graphite Carbon Graphite Carbon Graphite Internal Safety Relief Valve Iron Iron Iron

Iron
Ductile Iron Ductile Iron

Iron
Iron Ductile Iron

SPECIFICATION UNMOUNTED PUMPS


Pump Model Port Size (NPT) Inch G4195 GG4195 H4195 HJ4195 HL4195 AS4195 AK4195 AL4195 1 1 1 1 1 2 2 3 Nominal Capacity at Maximum Rated Speed 22 cSt (100 SSU) Liquid 60 Hz Motor Speed GPM 8 5 10 7 15 10 20 13 30 20 35 50 75 RPM 1800 1200 1800 1200 1800 1200 1800 1200 1800 1200 1200 1200 1200 50 Hz Motor Speed M/hr 1.5 0.9 3 2 2.8 1.8 4.5 3 7 4.5 8 11 17 RPM 1500 1000 1500 1000 1500 1000 1500 1000 1500 1000 1000 1000 1000

Maximum Pressure

Maximum Hydrostatic Pressure PSI 400 400 400 BAR 28 28 28 28 28 28 28 28

Steel Fitted Construction Recommended Above This Viscosity SSU (cSt) 7500 (1619) 7500 (1619) 25000 (5500) 7500 (1619)

Maximum Recommended Temperature Deg. F 225 225 225 225 225 225 225 225 Deg. C 107 107 107 107 107 107 107 107

Approximate Shipping Weight Lb. 20 20 44 44 44 85 85 86 Kg. 9 9 20 20 20 38 38 39

PSI (BAR)

100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU

400 400 400 400 400

Standard Buna-N seal from -20F. to +225F. (-29C. to +107C.) With special construction, temperatures from -40F. to +350F. (-40C. to +177C.) can be handled with this series. When steel fitted construction is required, GG will have steel rotor, HJ will have ductile iron rotor.

GG size has steel idler. Nominal capacities based on handling thin liquids. For viscosities above 15,000 SSU (3,300 cSt), provide details for recommendations. These models have ductile iron rotors; steel fitted rotors not necessary. If suction pressure exceeds 100 PSIG (7 BAR), consult factory.

Metric conversions are based on US measurements and rounded to the nearest whole number.

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2009

VIKING HEAVY DUTY PUMPS


SERIES 4195 STANDARD CONSTRUCTION DIRECT DRIVE UNITS (D DRIVE)
SERIES 4195 Pumps
with D Drive AS, AK and AL Sizes

Section Page Issue

144 144.3 D

with D Drive G, GG, H, HJ and HL Sizes

SERIES 4195 Pumps

Series 4195 pumps in the G, GG, H, HJ and HL size are designed for high-speed, heavy-duty service. The pump is connected by a flexible coupling with guard directly to a 50 Hz or 60 Hz motor. See series 4195D chart below. Both pump and motor mount on a sturdy formed steel base. This makes a very compact, rugged unit for heavy-duty service, handling many types of fluids up to 15,000 SSU (3,300 cSt). The three large size Series 4195D direct connected units all feature the 4195 high-speed pump connected by a flexible coupling with guard to 50 Hz or 60 Hz motor. See chart below. SPECIFICATIONS D DRIVE UNITS
Port Size (NPT) Inch G4195D GG4195D H4195D HJ4195D HL4195D AS4195D AK4195D AL4195D 1 1 1 1 1 2 2 3 Nominal Capacity at Maximum Rated Speed 22 cSt (100 SSU) Liquid 60 Hz Motor Speed GPM 8 5 10 7 15 10 20 13 30 20 35 50 75 RPM 1800 1200 1800 1200 1800 1200 1800 1200 1800 1200 1200 1200 1200 50 Hz Motor Speed M/hr 1.5 0.9 3 2 2.8 1.8 4.5 3 7 4.5 8 11 17 RPM 1500 1000 1500 1000 1500 1000 1500 1000 1500 1000 1000 1000 1000 PSI (BAR)

Both pump and motor are mounted on a heavy-duty formed steel base. The three larger sizes are equipped with ductile iron pump gears (rotor and idler). O-Ring head and valve gaskets, mechanical seals and automatic pressure lubrication systems are also standard construction. These pumps are also available with steel externals, see Section 154.
Dimensions for D DriveSee Page 144.7. Performance Data for D DriveSee Pages 144.13 through 144.26.

Pump Model

Maximum Pressure

Maximum Hydrostatic Pressure PSI 400 400 400 BAR 28 28 28 28 28 28 28 28

Steel Fitted Construction Recommended Above This Viscosity SSU (cSt) 7500 (1619) 7500 (1619) 25000 (5500) 7500 (1619)

Maximum Recommended Temperature Deg. F 225 225 225 225 225 225 225 225 Deg. C 107 107 107 107 107 107 107 107

Approximate Shipping Weight Lb. 46 46 69 69 69 215 215 220 Kg. 21 21 31 31 31 97 97 100

100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU

400 400 400 400 400

Nominal capacities based on handling thin liquids. With special construction, temperatures to + 350F. (177C.) can be handled with
this series.

For viscosities above 15,000 SSU (3,300 cSt), provide details for recommendations. These models have ductile iron rotors; steel fitted rotors not necessary. If suction pressure exceeds 100 PSIG (7 BAR), consult factory.

Metric conversions are based on US measurements and rounded to the nearest whole number.

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2009

Section Page Issue

144 144.4 D

VIKING HEAVY DUTY PUMPS


SERIES 495 STANDARD CONSTRUCTION FLANGE BRACKET UNMOUNTED PUMPS
Pressure Range Temperature Range Viscosity Range 250 PSI (17 BAR) for 100 SSU (20 cSt) and above 150 PSI (10 BAR) for 38 to 100 SSU (3 cSt to 20 cSt) 100 PSI (7 BAR) for below 38 SSU (3 cSt) - 40 F. to + 350F. (- 40 C. to + 176C.) 28 SSU to 15,000 SSU (0.1 cP to 3,300 cSt)

G, GG, H, HJ and HL Sizes

SERIES 495 Pumps

AS, AK and AL Sizes

SERIES 495 Pumps

Series 495 pumps are similar to the Series 4195 on preceding pages with the exception of a flange bracket mount casing.
Standard Construction Models Mounting Bracket (Units Only) G495 , GG495 H495 , HJ495 HL495 AS495 , AK495 , AL495 Iron Iron Iron Casing Iron Iron Iron Head Iron Iron Iron Rotor Iron Ductile Iron Ductile Iron

(Nominal Rating) All eight sizes are furnished with single mechanical seals, including Buna-N elastomer gaskets. Standard construction features internal type safety relief valve on pump head or casing (depending on pump size), O-Ring head and valve gaskets, and automatic pressure lubrication system on the three larger size pumps. The 495 series offers an optional flange port for sizes H-AL. Contact the factory for details.
Dimensions for Unmounted PumpsSee Page 144.8. Performance Data for Unmounted PumpsSee Pages 144.13 through 144.26.

GPM up to 75 (M/Hr up to 17)

CONSTRUCTION SERIES 495 (GG THROUGH AL SIZES)


Idler Iron Iron Ductile Iron Rotor Shaft and Idler Pin Steel Steel Steel Idler Bushing Carbon Graphite Carbon Graphite Carbon Graphite Internal Safety Relief Valve Iron Iron Iron

SPECIFICATION UNMOUNTED PUMPS


Port Size (NPT) Inch G495 GG495 H495 HJ495 HL495 AS495 AK495 AL495 1 1 1 1 1 2 2 3 Nominal Capacity at Maximum Rated Speed 22 cSt (100 SSU) Liquid 60 Hz Motor Speed GPM 8 5 10 7 15 10 20 13 30 20 35 50 75 RPM 1800 1200 1800 1200 1800 1200 1800 1200 1800 1200 1200 1200 1200 50 Hz Motor Speed M/hr 1.5 0.9 3 2 2.8 1.8 4.5 3 7 4.5 8 11 17 RPM 1500 1000 1500 1000 1500 1000 1500 1000 1500 1000 1000 1000 1000 PSI (BAR) Maximum Pressure Maximum Hydrostatic Pressure PSI 400 400 400 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU 400 400 400 400 400 BAR 28 28 28 28 28 28 28 28 Steel Fitted Construction Recommended Above This Viscosity SSU (cSt) 7500 (1619) 7500 (1619) 25000 (5500) 7500 (1619) Maximum Recommended Temperature Deg. F 225 225 225 225 225 225 225 225 Deg. C 107 107 107 107 107 107 107 107 Approximate Shipping Weight Lb. 18 18 40 40 40 80 80 81 Kg. 8 8 18 18 18 36 36 37

Pump Model

Consult factory for specific recommendations. Standard Buna-N seal from -20F. to +225F. (-29C. to +107C.) With special construction, temperatures from -40F. to +350F. (-40C. to +177C.) can be handled with this series. For viscosities above 15,000 SSU (3,300 cSt), provide details for recommendations. Nominal capacities based on handling thin liquids.
Metric conversions are based on US measurements and rounded to the nearest whole number.

Buna-N elastomer used in mechanical seal of Series 495 pumps. When steel fitted construction is required, GG will have steel rotor, HJ will have ductile iron rotor. GG size has steel idler. These models have ductile iron rotors; steel fitted rotors not necessary. If suction pressure exceeds 100 PSIG (7 BAR), consult factory.

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2009

VIKING HEAVY DUTY PUMPS


SERIES 495 STANDARD CONSTRUCTION FLANGE BRACKET MOUNTED UNITS (M DRIVE)

Section Page Issue

144 144.5 E

with M Drive G, GG, H, HJ and HL Sizes

SERIES 495 Pumps

with M Drive AS, AK and AL Sizes

SERIES 495 Pumps

For a compact horizontal mounting, the face mounted 495M heavy-duty pump units in all eight sizes include a combination motor C flange and square pump flange bracket with coupling connecting motor and pump. The three larger size pumps are equipped with ductile iron pump gears (rotor and idler) and SPECIFICATIONS M DRIVE UNITS
Port Size (NPT) Inch G495M GG495M H495M HJ495M HL495M AS495M AK495M AL495M 1 1 1 1 1 2 2 3 Nominal Capacity at Maximum Rated Speed 22 cSt (100 SSU) Liquid 60 Hz Motor Speed GPM 8 5 10 7 15 10 20 13 30 20 35 50 75 RPM 1800 1200 1800 1200 1800 1200 1800 1200 1800 1200 1200 1200 1200 50 Hz Motor Speed M/hr 1.5 0.9 3 2 2.8 1.8 4.5 3 7 4.5 8 11 17 RPM 1500 1000 1500 1000 1500 1000 1500 1000 1500 1000 1000 1000 1000 PSI (BAR)

automatic pressure lubrication system. All sizes have O-Ring head and valve gaskets and mechanical seals as standard construction. These pumps are also available with steel externals, see Section 154.
Dimensions for M DriveSee Page 144.9 and 144.10. Performance Data for M DriveSee Pages 144.13 through 144.26.

Pump Model

Maximum Pressure

Maximum Hydrostatic Pressure PSI 400 400 400 BAR 28 28 28 28 28 28 28 28

Steel Fitted Construction Recommended Above This Viscosity SSU (cSt) 7500 (1619) 7500 (1619) 25000 (5500) 7500 (1619)

Maximum Recommended Temperature Deg. F 225 225 225 225 225 225 225 225 Deg. C 107 107 107 107 107 107 107 107

Approximate Shipping Weight Lb. 28 28 50 50 50 90 90 95 Kg. 13 13 22 22 22 41 41 43

100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU

400 400 400 400 400

Nominal capacities based on handling thin liquids. With special construction, temperatures to + 350F. (177C.) can be handled with this
series.

For viscosities above 15,000 SSU (3,300 cSt), provide details for recommendations. These models have ductile iron rotors; steel fitted rotors not necessary. If suction pressure exceeds 100 PSIG (7 BAR), consult factory.

Metric conversions are based on US measurements and rounded to the nearest whole number.

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2009

Section Page Issue

144 144.6 C

VIKING HEAVY DUTY PUMPS


SERIES 4195 STANDARD CONSTRUCTION DIMENSIONS

These dimensions are average and not for construction purposes. Certified prints on request.

For specifications, see page 144.2.

DIMENSIONS SERIES 4195 UNMOUNTED PUMPS GGGHHJHL SIZES

MODEL NO.
G4195 GG4195 H4195 HJ4195 HL4195 in mm in mm

A
1

B
2.75 70 3.75 95

D
2.75 70 4.12 105

E
1.62 41 1.75 44

F
1.31 33 2.00 51

G
4.00 102 5.00 127

H
2.44 62 3.50 89

J
.34 9 .41 10

K
.94 24 1.50 38

L
.03 1 1.25 32

M
.66 17 .88 22

N
1.12 29 1.50 38

O
.31 8 .44 11

P
.62 16 .62 16

S
7.31 186

T
1.12 29

U
.500 12.70 .750

V
FLAT .19 x .09

W
2.66 67 3.28 83

X
.38 10 .75 19

10.00 1.62 254 41

19.05 4.76 x 2.38

For specifications, see page 144.2.

DIMENSIONS SERIES 4195 UNMOUNTED PUMPS ASAKAL SIZES

MODEL NO.
AS4195 in mm in mm in mm

A
2 2

E
2.88 73 2.88 73 2.88 73

F
2.00 51 2.00 51 2.00 51

G
6.75 171 6.75 171 6.75 171

H
4.00 102 4.00 102 4.00 102

J
.41 10 .41 10 .41 10

K
2.25 57 2.25 57 2.25 57

L
1.25 32 1.25 32 1.75 44

M
1.00 25 1.00 25 1.00 25

N
2.00 51 2.00 51 2.50 64

V
.25 x .12

W
7.00 178 7.00 178 7.00 178

Z
1.72 40 1.72 40 1.72 40

5.00 5.25 127 133

.44 1.12 12.12 2.50 1.000 11 29 308 60

.50 1.00 13 25

25.40 6.35 x 3.18 .25 x .12

AK4195

5.00 5.25 127 133

.44 1.12 12.12 2.50 1.000 11 29 308 60

.50 1.00 13 25

25.40 6.35 x 3.18 .25 x .12

AL4195

5.00 5.25 127 133

.44 1.12 12.12 2.50 1.000 11 29 308 60

.50 1.00 13 25

25.40 6.35 x 3.18

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2009

VIKING HEAVY DUTY PUMPS


SERIES 4195 STANDARD CONSTRUCTION DIMENSIONS

Section Page Issue

144 144.7 C

These dimensions are average and not for construction purposes. Certified prints on request.

For specifications, see page 144.3.

DIMENSIONS SERIES 4195 (D DRIVE) GGGHHJ HLASAKAL SIZES

MODEL NO. in G4195D GG4195D

B 2.75

D 3.50 89 3.50 89 4.12 114 4.12 114 5.25 133 4.50 114 5.25 133 6.25 159

E 1.50 38 1.50 38 2.12 54 2.94 75 2.94 75 3.69 94 2.94 75 4.00 102

F 20.50 445 20.50 521 20.50 521 29.00 635 29.00 635 29.00 660 29.00 737 39.00 991

H .75 19 .75 19 .75 19 1.00 25 1.00 25 1.00 25 1.00 25 1.38 35

J .75 19 .75 19 .75 19 1.50 38 1.50 38 1.50 38 1.50 38 1.38 35

K 8.50 216 8.50 216 8.50 216 9.00 229 9.00 229 9.00 229 9.00 229 16.00 406

L .38 10 .38 10 0 0 .25 6 .25 6 0 0 0 0 3.75 95

M 3.78 96 3.78 96 4.78 121 4.78 121 4.78 121

M1

N .62 16 .62 16 .62 16 .62 16 .62 16

P .62 13 .62 13 .62 13 .62 14 .62 14 .62 14 .62 14 .62 16

S 4.25 108 4.25 108 4.25 108 4.50 114 4.50 114 4.50 114 4.50 114 8.00 203

1 mm in 1 mm in 70 70 2.75

H4195D HJ4195D

mm in mm

3.75 95 3.75 95 3.75 95 5.00 127 5.00 127 5.00 127

56 frame motors (short base). (Available with G & GG 143T and 145T frame motors (long base). (Available 56, 143T and 145T frame motors. (Available with H, 182, 182T, 184, 184T frame motors. (Available with 213, 213T, 215, 215T frame motors. (Available with 254U, 254T, 256U, 256T frame motors. (Available Dimensions includes motor block, base height is 1. Dimension includes motor block, base height is 2 .
NOTE: All AS, AK, AL pump sizes available with any of the three motors shown in columns. with AK through AL size pumps.) H through AL size pumps.) H through AL size pumps.) HJ or HL size pumps.) with G & GG size pumps.) size pumps.)

HL4195D

in mm in 1

7.00 178 7.00 178 7.00 178

1.12 29 1.12 29 1.12 29

AS4195D AK4195D

mm in mm

AL4195D

in mm

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2009

Section Page Issue

144 144.8 C

VIKING HEAVY DUTY PUMPS


SERIES 495 STANDARD CONSTRUCTION DIMENSIONS

These dimensions are average and not for construction purposes. Certified prints on request.

For specifications, see page 144.4.

DIMENSIONS SERIES 495 UNMOUNTED PUMPS GGGHHJHL SIZES

MODEL NO. G495 GG495 H495 HJ495 HL495 in mm in mm

B 2.75 70 3.75 95

C 2.66 67 3.28 83

E 3.00 76 4.75 121

F 4.00 102 5.88 149

G .41 10 .56 14

H .50 13 .75 19

J 3.44 87 4.50 114

K 2.81 71 4.00 102

N 1.12 29 1.50 38

P .94 24 1.50 38

R 2.875 2.873 73 3.875 3.873 98

T 1.12 29 1.62 41

U .500 12.70 .750 19.05

X .62 16 .62 16

FLAT

.19 x .09 4.76 x 2.38

For specifications, see page 144.4.

DIMENSIONS SERIES 495 UNMOUNTED PUMPS ASAKAL SIZES

MODEL NO.

AS495 AK495

in

8.38 5.00 213 4.75 6.25 .56 .75

2.00 5.75 51 2.50 121 159 14 19 64 146 22 57 108 308 64 25.40 6.35 x 3.18 178 29 25 40 .75 2.25 4.250 12.12 2.50 1.000 4.248 .25 x .12 7.00 1.12 1.00 1.72

mm AL495 in mm 3

8.88 127 225

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2009

VIKING HEAVY DUTY PUMPS


SERIES 495 STANDARD CONSTRUCTION DIMENSIONS

Section Page Issue

144 144.9 D

These dimensions are average and not for construction purposes. Certified prints on request.

For specifications, see page 144.5.

DIMENSIONS SERIES 495 (M DRIVE) NEMA C GGGHHJHL SIZES


MODEL NO.
in mm in G495M GG495M mm in mm in mm in mm in mm in mm H495M HJ495M HL495M in mm in mm in mm in mm in mm 95 83 114 16 5 38 1 70 67 87 16 5 29 1 2.75 2.66 3.44 .62 .19 1.12

MOTOR FRAME
56C 143TC 145TC 182TC 184TC 56C 143TC 145TC

E
2.44 62

F
1.50 38 2.00 51 2.50 64 2.25 57 2.75 70 1.50 38 2.00 51 2.50 64 2.25 57 2.75 70 2.75 70 3.50 89

G
2.56 65

K
.34 SLOT 9

3.50 2.75 89 4.50 114 70 3.75 95 2.44 62 3.50 2.75 89 4.50 114 5.25 133 70 3.75 95 4.25 108

8.88 2.88 73 3.38 86 2.56 65 11.12 2.88 73 3.38 86 4.25 108 283 11.81 300 12.56 319 .34 9 .41 10 .41 10 225 9.56 243 .34 9 .41 10 .34 SLOT 9

3.75 3.28 4.50 .62

.19 1.50

182TC 184TC 213TC 215TC

NOTE: Jaw type coupling with straight jaws recommended to facilitate assembly of motor and pump to bracket. COUPLING IS GUARDED WITH PLATES OVER SIDE OPENINGS ON MOUNTING BRACKET.

For specifications, see page 144.5.

DIMENSIONS SERIES 495 (M DRIVE) NEMA C ASAKAL SIZES


Dimensions are correct for 182TC through 215TC
motors. For 254TC/256TC motors, add .88 to the dimensions shown. NOTE: Jaw type coupling with straight jaws recommended to facilitate assembly of motor and pump to bracket. COUPLING IS GUARDED WITH PLATES OVER SIDE OPENINGS ON MOUNTING BRACKET.

MODEL NO. AS495M AK495M AL495M in mm in mm

A 2

C 19.06

N 2.00

5.00 484 19.56 127 497

6.25

2.75

7.00

5.00

7.00

1.00

.56

8.44

6.38 51 2.50

.50

1.12

7.00

.19

1.00

159

70

178

127

178

25

14

214

162

64

13

29

178

25

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2009

Section Page Issue

144 144.10 C

VIKING HEAVY DUTY PUMPS


SERIES 495 STANDARD CONSTRUCTION

For specifications, see page 144.5.

DIMENSIONS SERIES 495 (M DRIVE) IEC Frame HHJHL SIZES

Brackets are designed for IEC motors with B14 mounting face. NOTE: Jaw type coupling with straight jaws recommended to facilitate assembly of motor and pump to bracket. COUPLING IS GUARDED WITH PLATES OVER SIDE OPENINGS ON MOUNTING BRACKET.

MODEL NO in H495M HJ495M mm in mm mm

MOTOR FRAME IEC 90

L 4.92

R 6.61 167.9

4.62 117.3 5.32 135.1

2.38 60.5 2.95 74.9

6.40 162.6 7.48 190.0

3.52 89.4 4.50 114.3

5.14 130.6 6.09 154.7

0.81 0.57 20.6 0.80 20.3 14.5

125.0 4.98 128.8 5.11 129.8 19.1 0.75

0.19 4.8 0.25 6.4

1.5

3.75 3.28 4.50

1.50 0.62

IEC 100/112

7.01 178.1 8.16 207.3

HL495M in 95.3 83.3 114.3 38.1 15.7

IEC 132

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2009

Você também pode gostar