For high grade multistage surge filtering.


ISOPULSE power filters are designed to provide high performance protection for sensitive equipment from the damaging effects of lightning surges, power transients and RF interference. ISOPULSE hardwire series comprises metal oxide varistor (MOV) surge diversion plus an LC low pass filter with MOV ratings chosen to suit the application. These filters are designed to absorb transverse and common mode transients and provide extremely low let-through voltages. ISOPULSE power filters cater for single and three phase applications. Printed circuit boards are used for models up to 125 amps to achieve size and weight reduction and make installation straightforward. ISOPULSE hardwired filters are available in quality IP55 rated enclosures, customised metal casing or mounted on a backplane for wiring directly into the switchboard. Options include larger surge ratings and additional neutral protection for installation on a sub-circuit. Tercels TRIMOV design feature provides thermal overload and overcurrent protection with a visual indication that the filter is functioning properly. ISOPULSE hardwired filters also offer the option of remote monitoring via connection to alarm contacts or RJ11/12 socket.

Perth
89 glengariff Dr Floreat WA 6014 Tel: (08) 9387 6188 Fax: (08) 9347 6588 email: info.wa@tercel.com.au

ISOPULSE products are guaranteed to be free from defects in material and workmanship for five years. Should any product prove to be defective for that reason during the warranty period it will be replaced without charge.
WHERE REQUIRED TERCEL PRODUCTS ARE AUSTRALIAN COMMUNICATIONS AUTHORITY (ACA) CERTIFIED.

Free advisory service


If you need to know more about: v Consultancy v Design v Project Management v Material Supply v Installation v Inspection v Testing v Maintenance

Ring Tercel now. We will respond immediately. For new product details, launches and updates, including distributor contact details, visit www.tercel.com.au

Supplied By

In the knowledge that Tercel employs state-of-the-art technology and its products are manufactured in Australia by an ISO9001 certified facility, customers are assured that their sensitive equipment is being protected with unequalled performance and quality.

Installation

Isopulse HW

Hardwire directly into switchboards, distribution boards or at the building power entry point as close as possible to the equipment being protected. The filters are available mounted on a backplane or housed in IP55 enclosures. A detailed set of installation instructions is provided with each unit.

Common Specifications
Operation Voltage: Nominal 240V/415V AC phase to neutral. Different voltages available upon request. Protection modes: Multi-stage filtering for transverse and common mode protection. Surge withstand: To ANSI C62.41 Categories A, B & C. AS1768-1991 Cat A,B & C. Frequency Response: 3db rollover less than1kHz. Alarms: Operating status local/external alarm capability. Cable entry: Bottom or sides input /output. Other configurations available. Environmental category: IP55 with suitable cable glands. To order ISOPULSE quote model number. For example, the IP10H1 is an ISOPULSE 10 amp hardwire single phase unit. ISOPULSE power filters have been tested by an independent NATA approved laboratory. +B with Backplane -N no Neutral Protection +N with Neutral Protection +E with Enclosure *Not IP55 rated enclosures

Individual Specifications Pic No Model No IP10H1* IP10HDC24* IP10HDC50* 1. 2. 2. IP20H1* IP20H3* IP20H3/40* IP32H1+B-N IP32H1+B+N IP32H1+E-N IP32H1+E+N IP63H1+B-N IP63H1+B+N IP63H1+E-N IP63H1+E+N IP125H1+B-N IP125H1+B+N IP125H1+E-N IP125H1+E+N IP40H3+B-N IP40H3+B+N IP40H3+E-N IP40H3+E+N Current Rating 10A 10A DC 10A DC 20A 20A 20A 32A 32A 32A 32A 63A 63A 63A 63A 125A 125A 125A 125A 40A 40A 40A 40A Phases Surge Dimensions Rating (kA) HxWxD (mm) 1 1 1 1 3 3 1 1 1 1 1 1 1 1 1 1 1 1 3 3 3 3 16+16 16+16 16+16 16+16 16+16 40+25 40+25 40+25 40+25 40+25 40+25 40+25 40+25 40+25 40+25 40+25 40+25 40+25 40+25 40+25 40+25 40+25 100x270x65 100x270x65 100x270x65 Wt kg 2 2 2

Individual Specifications Pic No Model No IP63H3+B-N IP63H3+B+N IP63H3+E-N IP63H3+E+N IP125H3+B-N IP125H3+B+N IP125H3+E-N IP125H3+E+N IP200H3+B-N IP200H3+B+N IP200H3+E-N IP200H3+E+N IP315H3+B-N IP315H3+B+N IP315H3+E-N IP315H3+E+N IP450H3+B-N IP450H3+B+N IP450H3+E-N IP450H3+E+N IP630H3+B-N IP630H3+B+N IP630H3+E-N IP630H3+E+N Current Rating 63A 63A 63A 63A 125A 125A 125A 125A 200A 200A 200A 200A 315A 315A 315A 315A 450A 450A 450A 450A 630A 630A 630A 630A Phases Surge Dimensions Rating (kA) HxWxD (mm) 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 40+25 40+25 40+25 40+25 40+25 40+25 40+25 40+25 70+40 70+40 70+40 70+40 70+40 70+40 70+40 70+40 70+40 70+40 70+40 70+40 70+40 70+40 70+40 70+40 450x420x175 450x420x175 500x500x205 500x500x205 450x420x175 450x420x175 500x500x205 500x500x205 650x600x180 650x600x180 750x690x235 750x690x235 850x800x180 850x800x180 950x950x330 950x950x330 850x800x180 850x800x180 950x950x330 950x950x330 850x800x320 850x800x320 950x950x345 950x950x345 Wt kg 15 15 25 25 15 15 25 25 25 25 60 60 75 75 122 122 75 75 122 122 90 90 160 160

Legend

130x330x78 2.5 352x272x102 3.5 352x272x102 4 335x275x120 335x275x120 380x300x210 380x300x210 450x470x185 450x470x185 500x500x210 500x500x210 450x470x185 450x470x185 500x500x210 500x500x210 400x450x100 400x450x100 450x500x120 450x500x120 5 5 10 10 15 15 20 20 15 15 20 20 7 7 12.5 12.5

3. 3.

Problem Solving
Whilst most problems in this field are solved with off-the-shelf products, Tercel can design for unusual applications. Tercel provides this service.

Configurations above 630 amps are available eg. 800, 1000, 1250, 1630A. Different surge ratings are available upon request. Dimensions, mounting and full installation instructions available from Tercel technical notes. Due to continuing upgrades to products specifications can change without notice.