131451 - CONTROL SYSTEMS LAB MANUAL


Dec 2011-April 2012

cl u

si

ve

.b l

og

sp ot

.c o

DEPARTMENT OF ELECTRICAL & ELECTRONICS ENGINEERING

131451- CONTROL SYSTEMS LABORATORY

NAME OF THE STUDENT

: ____________________________

REGISTER NUMBER

: ____________________________

SIGNATURE OF THE STAFF:

.e

ee

ex

TOTAL MARKS

cl u

si

ve

ACADEMIC YEAR

: Dec 2011- Apr 2012

: -------- / 10

.b l

og

CLASS

: II- EEE- A / B

sp ot

.c o

LIST OF EXPERIMENTS

1.

Determination of transfer function parameters of Armature controlled DC (servo) motor.

3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13.

Determination of transfer function parameters of an AC servomotor. Analog simulation of type-0 and type-1 systems

Stability analysis of linear systems. DC and AC position control systems.

Study of synchros Design and implementation of compensators. Design of P, PI and PID controllers.

. P = 45, TOTAL = 45

.e

Determination of transfer function parameters of DC generators.

ee

Stepper motor control system

ex

cl u

si

ve

Digital simulation of second order systems.

.b l

Digital simulation of first order systems

og

sp ot

.c o

2.

Determination of transfer function parameters of Field controlled DC (servo) motor.

INDEX
Expt. NO.
1 2 3 4 5 6 7 8 9 10 11 12 13

DATE

Title

MARKS (10)

SIGN. OF THE STAFF

Total Marks

.e

ee

ex

cl u

si

ve

.b l
Signature of the faculty:

og

sp ot

.c o

5
EXPT. NO.: DATE:

TRANSFER FUNCTION OF ARMATURE CONTROLLED DC SERVOMOTOR


AIM: To determine the transfer function of an armature controlled dc servomotor. APPARATUS REQUIRED:

THEORY:

Transfer function is defined as the ratio of Laplace transform of the output variable to the Laplace transform of input variable at zero initial conditions. Armature controlled DC shunt motor

In this system,

.e

ee

Ra = Resistance of armature in La= Inductance of armature windings in H Ia = Armature current in A If = Field current in A e = Applied armature voltage in V eb = back emf in V Tm = Torque developed by the motor in Nm

ex

cl u

si

ve

.b l

og

sp ot

.c o

6 J = Equivalent moment of inertia of motor and load referred to motor shaft in kgm2 B= Equivalent viscous friction coefficient of inertia of motor and load referred to motor shaft in Nm/(rad/s) In Servo applications, DC motors are generally used in the linear range of the magnetization curve. Therefore, the air gap flux is proportional to the field current. If = Kf If ,where Kf is a constant. ----------------------------- (1) The torque Tm developed by the motor is proportional to the product of the armature current and air gap flux. Tm Ia

Taking Laplace transforms for the equations (4) to (7), we get Eb(s) = Kb s (s) -------------------------------------------- (8)

From equations (8) to (10) , the transfer function of the system is obtained as

(s La + Ra ) Ia(s) = E(s) Eb(s). ------------------------------- (9) ( J s2+ B s) (s) = Tm (s) = Kt Ia(s) ---------------------------- (10)

Jd 2/dt2 + B d/dt = Kt Ia ---------------------------------------(7)

.e

Equating equations (3) and (6)

ee

The torque equation is Tm = Jd2/dt2 + B d/dt ------------------------------------------ (6)

ex

cl u

The differential equation of the armature circuit is e = IaRa + La dIa/dt + eb ----------------------------------------- (5)

si

ve

eb = Kb d/dt, where Kb is the back emf constant.----------------(4)

.b l

The motor back emf being proportional to speed is given by eb d/dt,

og

sp ot

In the armature controlled DC motor, the field current is kept constant. So the above equation can be written as Tm = Kt Ia , Where Kt is known as motor torque constant.------ (3)

.c o

Tm =Ki Ia = Ki Kf If Ia , where Ki is a constant --------------(2)

Block diagram Using the above equations, the block diagram for the armature controlled DC motor is given below: E(s) + (s)

(s)
Eb(s)

1/[Ra+sLa]

Kt

1/s[Js+B]

.e

ee

ex

cl u

si

ve

.b l

og

sp ot

1. Circuit diagram to determine Kt and Kb

.c o

s Kb

8 2. Circuit diagram to determine Ra:

3. Circuit diagram to determine La:

1. 2. 3. 4. 5. 6. 7. 8. 9.

Initially keep all the switches in the off position. Keep all the voltage adjustment knobs in the minimum position. Give connections. Switch on the power and the SPST switches S1 and S2. Adjust the field voltage to the rated value. Apply the armature voltage until the motor runs at the rated speed. Apply load and note the armature voltage, current and spring balance readings. Calculate torque and plot the graph between torque and armature current. Determine Kt from graph.

.e

i)Load test to determine Kt

ee

PROCEDURE:

ex

cl u

si

ve

.b l

og

sp ot

.c o

9 ii)No-Load test to determine Kb. 1. 2. 3. 4. 5. 6. 7. 8. Initially keep all the switches in the off position. Keep all the voltage adjustment knobs in the minimum position. Give connections. Switch on the power and the SPST switches S1 and S2. Set the field voltage to the rated value. Adjust the armature voltage and note the armature voltage, current and speed. Calculate the back emf eb and plot the graph between back emf and Determine Kb from graph. iii) To determine Ra: 1. 2. 3. 4. 5. 6. Initially keep all the switches in the off position. Keep all the voltage adjustment knobs in the minimum position. Give connections. Switch on the power and the SPST switches S1. Note the armature current for various armature voltages. Calculate Ra.

Where r is the radius of the brake drum.

Tabulation to determine Kt S.No. Field Armature Armature Current Voltage Current If (A) Va (V) Ia (A)

ee

ex

1. 2. 3. 4. 5. 6. 7.

Initially keep all the switches in the off position. Keep all the voltage adjustment knobs in the minimum position. Give connections. Switch on the power . Apply ac voltage to armature winding Note down the current for various input ac voltage . Calculate Ra.

cl u

si

ve

.b l

Spring Balance Readings (kg) S1 S2

og

iv) To determine La:

sp ot

.c o
Speed(N) rpm Torque T= 9.81(S1S2)r (Nm)

.e

r = _____________m

10

Tabulation to determine Kb S.No. Armature Voltage Va (V) Armature Current Ia (A) Speed N (rpm) Eb= Va-Ia Ra (V) = 2N/60 (rad/sec)

Tabulation to determine Ra S.No. Armature Armature Voltage Current Va (V) Ia (A) Ra ()

Calculation by least square method

Tabulation to determine Za S.No. Armature Armature Current Voltage Va (V) Ia (A) Za ()

Average Za = ________

Ra = [V1I1 +V2I2 +V3I3+V4I4 ] / (I12+I22+I32+I42)

.e

ee

ex

cl u

si

ve

.b l

og

sp ot

.c o

m
-

11

MODEL GRAPH

To find Kt Torque (Nm) Eb( V)

To find Kb

Ia(A)

(rad/sec)

Ra = ..Ohms Za = .. Ohms La = (Za2 Ra2 ) / 2f = . H f = 50 Hz J = 0.074 kg/m2, B = 0.001Nm/rad/sec From Graph,

RESULT:

INFERENCE:

.e

ee

ex

cl u

Kb = Back emf constant = Eb / = . V/(rad/s)

si

Kt = Torque constant = T / Ia = Nm / A

ve

.b l

og

sp ot

.c o

MODEL CALCULATION

12
EXPT. NO.: DATE:

TRANSFER FUNCTION OF FIELD CONTROLLED DC SERVOMOTOR


AIM: To determine the transfer function of a field controlled dc servomotor. APPARATUS REQUIRED:

THEORY:

Armature controlled DC shunt motor

In this system,

.e

ee

Rf = Resistance of the field winding in Lf= Inductance of the field windings in H Ia = Armature current in A If = Field current in A e = Applied armature voltage in V eb = back emf in V ef = Field voltage in V

ex

cl u

si

ve

.b l

The transfer function is defined as the ratio of Laplace transform of the output variable to the Laplace transform of input variable at zero initial conditions.

og

sp ot

.c o

13 Tm = Torque developed by the motor in Nm J = Equivalent moment of inertia of motor and load referred to motor shaft in kgm2 B= Equivalent viscous friction coefficient of inertia of motor and load referred to motor shaft in Nm/(rad/s) In Servo applications, the DC motors are generally used in the linear range of the magnetization curve. Therefore the air gap flux is proportional to the field current. If = Kf If ,where Kf is a constant. -------------------------------- (1) The torque Tm developed by the motor is proportional to the product of the armature current and air gap flux. Tm Ia Tm =K Ia = K Kf If Ia = Km Kf If , where Ki is a constant ----(2)

Appling Kirchhoffs voltage law to the field circuit, we have Lf dIf/dt + RIf = ef ------------------------------------------------- (3) Now the shaft torque Tm is used for driving the load against the inertia and frictional torque. Hence, Tm = Jd2/dt2 + B d/dt ------------------------------------------- (4)

Tm(s) = KmKf If (s)

----------------------------------------------- (5)

Ef(s) = (s Lf + Rf) If(s) -------------------------------------------- (6) Tm(s) = (J s2+ B s) (s) ------------------------------------------- (7)

Solving equations (5) to (7), we get the transfer function of the system as

.e

ee

ex

cl u

si

Taking Laplace transforms of equations (2) to (4), we get

ve

.b l

og

sp ot

.c o

14 1. Circuit diagram to determine KmKf

2. Circuit diagram to determine Rf

3. Circuit diagram to determine Lf

.e

ee

ex

cl u

si

ve

.b l

og

sp ot

.c o

15 PROCEDURE: i)Load test to determine KmKf 1. Initially keep all the switches in the OFF position. 2. Keep all the voltage adjustment knobs in the minimum position. 3. Give connections. 4. Switch ON the power and the SPST switches S1 and S2. 5. Apply 50% of the rated field voltage. 6. Apply the 50% of the rated armature voltage. 7. Apply load and note the field current and spring balance readings. 8. Vary the field voltage and repeat the previous step. 9. Calculate torque and plot the graph between torque and field current. 10. Determine KmKf from graph.

.e

1. 2. 3. 4. 5. 6. 7.

Initially keep all the switches in the OFF position. Keep all the voltage adjustment knobs in the minimum position. Give connections. Switch ON the power . Apply AC voltage to field windings Note the currents for various input AC voltages. Calculate Lf.

ee

ex

cl u

si

ve

iii) To determine Lf

.b l

1. 2. 3. 4. 5. 6.

Initially keep all the switches in the OFF position. Keep all the voltage adjustment knobs in the minimum position. Give connections. Switch ON the power and the SPST switch S2. Note the field currents for various field voltages. Calculate Rf.

og

sp ot

.c o

ii) To determine Rf

16 Tabulation to determine KmKf S.No Field Current If (A) Spring Balance Readings (kg) S1 S2 Torque T = 9.81(S1-S2)r (Nm)

Where r is the radius of the brake drum.

Calculation by least square method Rf = [V1I1 +V2I2 +V3I3+V4I4 ] / (I12+I22+I32+I42)

.e

ee

ex

Tabulation to determine Zf S.No. Field Voltage Ef (V) Field Current If (A) Zf ()

Average Zf = ________

cl u

si

ve

.b l

S.No.

Field Voltage Ef (V)

Field Current If (A)

og

Tabulation to determine Rf

sp ot
Rf ()

r = _____________m

.c o

17 MODEL GRAPH

To find KmKf Torque (Nm)

If (A) MODEL CALCULATIONS 1. Rf = ..Ohms 2. Zf = .. Ohms 3. Lf = (Zf2 Rf2 ) / 2f = . H 4. f = 50 Hz 5. J = 0.074 kg/m2, B = 0.001Nm/rad/s

RESULT:

INFERENCE:

.e

ee

ex

cl u

si

ve

.b l

og

6. From Graph, KmKf = T / If = Nm / A

sp ot

.c o

18

EXPT. NO: DATE :

DETERMINATION OF TRANSFER FUNCTION PARAMETERS OF AC SERVO MOTOR


AIM: To derive the transfer function of the given AC servomotor and experimentally determine the transfer function parameters. APPRATUS REQUIRED:

1.

3.

Motor time constant m=

ee

ex

2.

Motor gain constant Km =

Where K1 = slope of torque - control phase voltage characteristics K2= slope of torque -speed characteristics J = Moment of inertia of load and the rotor B= viscous frictional coefficient of load and the rotor

THEORY
When the objective of a system is to control the position of an object, then the system is called a servomechanism. The motors that are used in automatic control systems are called servomotors. Servomotors are used to convert an electrical signal (control voltage) into an angular displacement of the shaft. In general, servomotors have the following features. 1. Linear relationship between speed and electrical control signal 2. Steady state stability 3. Wide range of speed control

.e

cl u

Motor transfer function (s) Km = Eo (s) s (1+s.m)

si

ve

K1 K2 + B J K2 + B

.b l

og

FORMULA:

sp ot

.c o

19 4. Linearity of mechanical characteristics throughout the entire speed range 5. Low mechanical and electrical inertia 6. Fast response Derivation of Transfer Function: Let Tm = Torque developed by the servomotor = angular displacement of the rotor = d / dt = angular speed TL = torque required by the load J = Moment of inertia of the load and the rotor B = Viscous frictional coefficient of the load and the rotor K1 = slope of the control phase voltage and torque characteristics. K2 = slope of the speed and torque characteristics.

K1 Ec (s) K2 s (s) = J s2 (s) + B s (s)(4)

ee

ex

.e

(s)
=

cl u

K1 e c K2 d /dt = J d 2 + B d ....(3) dt dt Taking Laplace Transform

si

ve

.b l
K1

TL = J d2 + B.d . (2) dt2 dt At equilibrium, the motor torque is equal to load torque. Hence,

og

sp ot
=

The transfer function of the AC servomotor can be obtained by torque equation. The motor developed torque is given by Tm = K1 e c K2 d(1) dt The rotating part of the motor and the load can be modeled by

.c o

T.F =

Ec (s) K1 B + K2 J

s (K2+s J+B)

Where motor gain constant Km =

and motor time constant m = B + K2

Km s (1 +s m)

20 PROCEDURE:
I. DETERMINATION OF TORQUE SPEED CHARACTERISTICS

1. Give the connections. 2. Connect voltmeter or a digital Multimeter across the control winding. 3. Apply rated voltage to the reference phase winding and control phase winding. 4. Note the no load speed. 5. Apply load in steps. For each load, note the speed. 6. Repeat steps 4,5 for various control voltage levels and tabulate the readings.
II. DETERMINATION OF TORQUE CONTROL VOLTAGE CHARACTERISTICS

Radius of brake drum =________ Vc = N rpm

cl u

si

ve

Torque Speed Characteristics

.b l
Vc = N rpm

og

sp ot

.c o
Load g

1. 2. 3. 4.

Make connections. Connect voltmeter or a digital Multimeter across the control phase winding Apply rated Voltage to Reference phase winding. Apply a certain voltage to the control phase winding and make the motor run at low speed. Note the voltage and the no load speed. 5. Apply load to motor. Motor speed will decrease. Increase the control voltage until the motor runs at same speed as on no-load. Note the control voltage and load. 6. Repeat steps 5 for various loads 7. Repeat 4-6 for various speeds and tabulate.

Model Graph

Torque N-m

.e

ee

Load g

Torque N-m

Load g

Torque N-m

Vc = N rpm

Torque N-m

ex

Speed (rpm)

21 Torque Control Voltage Characteristics N1 = Vc V N2 = Vc V N3 = Vc V

Load g

Torque N-m

Load g

Torque N-m

Load g

Torque N-m

ee

Given ,

From Calculations, Km = m =

From Graph , K1 =

K2 =

B= J=

.e

ex

cl u

Torque N-m

Control voltage (Volts)

si

ve

.b l

og

Model Graph

sp ot

.c o

RESULT:

INFERENCE:

w w w .e ee ex cl u si ve .b l og sp ot .c o

m
22

23
EXPT. NO: : DATE

ANALOG SIMULATION OF TYPE-0 AND TYPE-1 SYSTEM


AIM: To simulate the time response characteristics of I order and II order, type 0 and type-1 systems. APPARATUS REQUIRED:

Order of the system:

Type of the system is given by the number of poles of the loop transfer function at the origin. G(s)H(s) = K P(s) / Q(s) (s+z1) (s+z2) (s+z3) .. = sN (s+p1) (s+p2) (s+p3) ..

If N=0, the system is a Type Zero system. If N=1, the system is a Type One system. If N=0, the system is a Type Two system.

Type of the system

If n=0, then system is Zero-Order system. If n=1, then system is First-Order system. If n=0, then system is Second-Order system.

.e

ee

Q(s) =ao sn + a1sn-1 + a2 sn-2 + .+ an-1 s + a n

ex

cl u

P(s) --- Numerator polynomial Q(s) --- Denominator polynomial

si

ve

The order of the system is given by the order of the differential equation governing the system. The input-output relationship of a system can be expressed by transfer function. Transfer function of a system is obtained by taking Laplace transform of the differential equation governing the system and rearranging them as ratio of output and input polynomials in s. The order is given by the maximum power of s in denominator polynomial Q(s) T(s) = P(s) / Q(s)

.b l

og

sp ot

.c o

THEORY:

24

First Order Type 0 system The generalized transfer function for first order Type 0 system is T(s) = C(s) / R(s) = 1/(1+s) --------------------------------------------------------(1) C(s) ---- Output of the system R(s) ----- Reference input to the system. If input is a Step input R(s) = 1/s ----------------------------------------------------- (2) From eqn (1)

(1+s) substituting for R(s), 1 C(s) = s (1+s) 1

------------------------------------(4)

cl u

C(t) = 1 e-t/
PROCEDURE:

si

ve

To find C(t) , Take Inverse Laplace Transform of eqn (4),

.b l

1. Give the connections as per the block diagram in the process control simulator using the front panel diagram . 3. Observe the Output (process value or PV) using CRO and plot it in the graph. 4. Tabulate the reading and calculate the % error. 5. Repeat the procedure in closed loop condition.

2. Set the Input (set point) value using the set value knob.

.e

ee

ex

og

sp ot
------------------(5)

.c o

C(s) =

R(s)

---------------------------------------(3)

25 TABULATION FOR FIRST ORDER SYSTEM: (a)Type Zero system Loop type Set Point SP (V) Process variable PV (V) Settling Time (s) Error SP-PV (V) % Error SP-PV x 100% SP

Open Loop Closed Loop (b)Type One System

Open loop Closed loop

TABULATION FOR SECOND ORDER SYSTEM

Loop type

Loop type

(b)Type One system Set Point SP (V) Process variable PV (V) Settling Time (s) Error SP-PV (V) % Error SP-PV x 100% SP

Open loop Closed loop

.e

Closed loop

ee

Open loop

ex

Set Point SP (V)

Process variable PV (V)

cl u

si

(a)Type Zero system

ve

.b l
Settling Time (s) Error SP-PV (V)

og
% Error SP-PV x 100% SP

sp ot

.c o

Loop type

Set Point SP (V)

Process variable PV (V)

Settling Time (s)

Error SP-PV (V)

% Error SP-PV x 100% SP

RESULT:

INFERENCE:

w w w .e ee ex cl u si ve .b l og sp ot .c o

m
26

27 EXPT. NO: DATE :

DIGITAL SIMULATION OF FIRST ORDER SYSTEMS (i) Digital Simulation of first order Linear and Non Linear SISO Systems
AIM: To digitally simulate the time response characteristics of Linear and Non Linear SISO systems using state variable formulation. APPARATU REQUIRED:

PROGRAM/ SIMULINK MODEL:

.e

ee

ex

Where A = n x n system matrix, B = n x m input matrix, C= p x n output matrix and D = p x m transmission matrix,

cl u

si

ve

SISO linear systems can be easily defined with transfer function analysis. The transfer function approach can be linked easily with the state variable approach. The state model of a linear-time invariant system is given by the following equations: X(t) = A X(t) + B U(t) State equation Y(t) = C X(t) + D U(t) Output equation

.b l

og

sp ot

THEORY:

.c o

A PC with MATLAB package.

PROGRAM:

w w w .e ee ex cl u si ve .b l og sp ot .c o

m
28

RESULT:

INFERENCE:

w w w .e ee ex cl u si ve .b l og sp ot .c o

m
29

30

(ii) Digital Simulation of Multi-Input Multi-Output Linear Systems


AIM: To digitally simulate the time response characteristics of MIMO Linear system using state-variable formulation. APPARATUS REQUIRED: THEORY: State Variable approach is a more general mathematical representation of a system, which, along with the output, yields information about the state of the system variables at some predetermined points along the flow of signals. It is a direct timedomain approach, which provides a basis for modern control theory and system optimization. PC MATLAB Package.

.b l

u1(t) u2(t)
. .

The state vector X determines a point (called state point) in an n - dimensional space, called state space. The state and output equations constitute the state model of the system.

.e

ee

X(t) = A X(t) + B U(t) State equation Y(t) = C X(t) + D U(t) Output equation

ex

. ....... x1(t) x2(t) xn(t)

cl u

um(t)

si

ve

Controlled system State variables (n)

y1(t) y2(t)

og

sp ot
U

.c o

m
X

. .

Controlled system

yp(t)

PROGRAM:

w w w .e ee ex cl u si ve .b l og sp ot .c o

m
31

RESULT:

INFERENCE:

w w w .e ee ex cl u si ve .b l og sp ot .c o

m
32

33 Expt. No.: Date:

DIGITAL SIMULATION OF SECOND ORDER SYSTEMS


AIM: To digitally simulate the time response characteristics of second order linear and non-linear system with saturation and dead zone. APPARATU REQUIRED: A PC with MATLAB package.

.e

ee

ex

cl u

si

ve

.b l

og

sp ot

.c o

PROGRAM / SIMULINK MODEL:

34

SIMULINK MODEL:

RESULT:

INFERENCE:

.e

ee

ex

cl u

si

ve

.b l

og

sp ot

.c o

35

Expt. No.: Date:

STABILITY ANALYSIS OF LINEAR SYSTEMS


AIM: To analyze the stability of linear system using Bode plot/ Root Locus / Nyquist Plot.

APPARATUS REQUIRED:

THEORY:

PROGRAM:

.e

ee

1. Write a Program to obtain the Bode plot / Root locus / Nyquist plot for the given system. 2. Determine the stability of given system using the plots obtained.

ex

cl u

PROCEDURE:

si

ve

A Linear Time-Invariant Systems is stable if the following two conditions of system stability are satisfied When the system is excited by a bounded input, the output is also bounded. In the absence of the input, the output tends towards zero, irrespective of the initial conditions.

.b l

og

sp ot

.c o

A PC with MATLAB package.

RESULT:

INFERENCE:

w w w .e ee ex cl u si ve .b l og sp ot .c o

m
36

37

EXPT. NO: : DATE

CLOSED LOOP DC POSITION CONTROL SYSTEM


AIM: To study the operation of closed loop position control system (DC Servomotor) with a PI controller. APPARATUS REQUIRED:

.e

ee

Fig. 1 Block Diagram

ex

cl u

si

THEORY: A pair of potentiometers is used to convert the input and output positions into proportional electrical signals. The desired position is set on the input potentiometer and the actual position is fed to feedback potentiometer. The difference between the two angular positions generates an error signal, which is amplified and fed to armature circuit of the DC motor. If an error exists , the motor develops a torque to rotate the output in such a way as to reduce the error to zero. The rotation of the motor stops when the error signal is zero, i.e., when the desired position is reached.

ve

.b l

og

sp ot

.c o

38

PROCEDURE:

1. Switch on the system. Keep the pulse release switch in OFF position.

note the output position.

3. Note SP voltage , PV voltage, P voltage and PI output voltage. 4. Calculate KP using the formula KP = P/(SP-PV).

.e

ee

ex

cl u

2. Vary the set point with the pulse release switch in the ON position and

si

ve

.b l

og

Fig.(2.).Front Panel

sp ot

.c o

39 TABULATION S.NO.
POSITION (degrees)

set

output

Error (set output) in degrees

RESULT:

INFERENCE:

.e

ee

ex

cl u

si

ve

.b l

og

sp ot

.c o

40
EXPT. NO: DATE :

CLOSED LOOP AC POSITION CONTROL SYSTEM


AIM: To study the closed loop operation of AC position control system (AC Servomotor) with PI controller.

APPARATUS REQUIRED:

CONSTRUCTIONAL DETAILS

The rotor construction is usually of squirrel cage or drag-cup type. The squirrel cage rotor is made of laminations. The rotor bars are placed on the slots and short-circuited at both ends by end rings. The diameter of the rotor is kept small in order to reduce inertia and to obtain good accelerating characteristics. Drag cup construction is employed for very low inertia applications. In this type of construction, the rotor will be in the form of hollow cylinder made of aluminium. The aluminium cylinder itself acts as short-circuited rotor conductors.

The stator windings are excited by voltages of equal rms magnitude and 90o phase difference. This results in exciting currents i1 and i2 displaced in phase by 90 o and having identical rms values. These currents give rise to a rotating magnetic field of constant magnitude. The direction of rotation depends on the phase relationship of the two currents (or voltages). The exciting current shown in fig.2 produces a clockwise rotating magnetic field. When i1 is shifted by 180 o, an anticlockwise rotating magnetic field is produced. This rotating magnetic field sweeps over the rotor conductors. The rotor conductor experience a change in flux and so voltages are

WORKING PRINCIPLES

.e

ee

ex

The AC servomotor is a two-phase induction motor with some special design features. The stator consists of two pole pairs (A-B and C-D) mounted on the inner periphery of the stator, such that their axes are at an angle of 90o in space. Each pole pair carries a winding, one winding is called the reference winding and other winding is called the control winding. The exciting currents in the two windings should have a phase displacement of 90o. The supply used to drive the motor is single-phase and hence a phase advancing capacitor is connected to one of the phases to produce a phase difference of 90 o. The stator constructional features of AC servomotor are shown in fig.1.

cl u

si

ve

.b l

og

sp ot

THEORY:

.c o

41 induced in rotor conductors. This results in circulating currents in the short-circuited rotor conductors resulting in rotor flux. Due to the interaction of stator & rotor flux, a mechanical force (or Torque) is developed in the rotor and the rotor starts moving in the same direction as that of rotating magnetic field.

Fig 1 Stator Construction of AC Servomotor

Fig 2.Waveforms of Stator & Rotor Excitation Current

Fig.3 Basic Block Diagram of AC Position Control System

.e

ee

ex

cl u

si

ve

.b l

og

sp ot

.c o

42

Fig.4. Block Diagram

1. Switch ON the system. Keep the pulse release switch in the OFF position. 2. Vary the set point with the pulse release switch in the ON and note the output position.

.e

4. Calculate KP using the formula KP = P/(SP-PV).

ee

3. Note the SP voltage, PV voltage, P voltage and PI output voltage.

ex

cl u

si

ve

PROCEDURE:

.b l

og

sp ot

.c o

43 TABULATION S.NO. SET OUTPUT POSITION POSITION (degrees) (degrees) ERROR=(set position-output position) (degrees)

RESULT:

INFERENCE:

.e

ee

ex

cl u

si

ve

.b l

og

sp ot

.c o

44

Ex. No: Date:

STEPPER MOTOR Aim:


To study the Stepper motor

Theory:
Stepper motors are highly accurate pulse-driven motors that change their angular position in steps, in response to input pulses from digitally controlled systems. A stepper or stepping motor converts electronic pulses into proportionate mechanical movement. Each revolution of the stepper motor's shaft is made up of a series of discrete individual steps. A step is defined as the angular rotation produced by the output shaft each time the motor receives a step pulse. These types of motors are very popular in digital control circuits, such as robotics, because they are ideally suited for receiving digital pulses for step control. Each step causes the shaft to rotate a certain number of degrees. A step angle represents the rotation of the output shaft caused by each step, measured in degrees. Figure.1. illustrates a simple application for a stepper motor. Each time the controller receives an input signal, the paper is driven a certain incremental distance.

In addition to the paper drive mechanism in a printer, stepper motors are also popular in machine tools, process control systems, tape and disk drive systems, and programmable controllers.

.e

ee

ex

Fig.1

cl u

si

ve

.b l

og

sp ot

.c o

45 The Common Features of stepper motors are Brushless Stepper motors are brushless. The commentator and brushes of conventional motors are some of the most failure-prone components, and they create electrical arcs that are undesirable or dangerous in some environments. Load Independent Stepper motors will turn at a set speed regardless of load as long as the load does not exceed the torque rating for the motor. Open Loop Positioning Stepper motors move in quantified increments or steps. As long as the motor runs within its torque specification, the position of the shaft is known at all times without the need for a feedback mechanism. Holding Torque Stepper motors are able to hold the shaft stationary. Excellent response to start-up, stopping and reverse.

1. Permanent-magnet stepper motor

.e

The teeth on the rotor surface and the stator pole faces are offset so that there will be only a limited number of rotor teeth aligning themselves with an energized stator pole. The number of teeth on the rotor and stator determine the step angle that will occur each time the polarity of the winding is reversed. The greater the number of teeth, the smaller the step angle.

ee

ex

cl u

Fig.2

si

ve

.b l

The permanent-magnet stepper motor operates on the reaction between a permanent-magnet rotor and an electromagnetic field. Figure shows a basic two-pole PM stepper motor. The rotor shown in Figure (a) has a permanent magnet mounted at each end. The stator is illustrated in Figure (b). Both the stator and rotor are shown as having teeth

og

sp ot

.c o

Types of Stepper Motor

46

2.Variable-reluctance (VR) stepper motor


The variable-reluctance (VR) stepper motor differs from the PM stepper in that it has no permanent-magnet rotor and no residual torque to hold the rotor at one position when turned off. When the stator coils are energized, the rotor teeth will align with the energized stator poles. This type of motor operates on the principle of minimizing the reluctance along the path of the applied magnetic field. By alternating the windings that are energized in the stator, the stator field changes, and the rotor is moved to a new position. The stator of a variable-reluctance stepper motor has a magnetic core constructed with a stack of steel laminations. The rotor is made of unmagnetized soft steel with teeth and slots. The relationship among step angle, rotor teeth, and stator teeth is expressed using the following equation:

.e

ee

ex

An important characteristic of the PM stepper motor is that it can maintain the holding torque indefinitely when the rotor is stopped. Figure (a) shows a permanent magnet stepper motor with four stator windings. By pulsing the stator coils in a desired sequence, it is possible to control the speed and direction of the motor. Figure (b) shows the timing diagram for the pulses required to rotate the PM stepper motor.

cl u

si

ve

.b l

og

The holding torque is defined as the amount of torque required to move the rotor one full step with the stator energized.

sp ot

Fig.3

.c o

47

N s Nr 360 Ns Nr

------(1)

In this circuit, the rotor is shown with fewer teeth than the stator. This ensures that only one set of stator and rotor teeth will align at any given instant. The stator coils are energized in groups referred to as phases. According to above Eq., the rotor will turn 30 each time a pulse is applied. Figure (a) shows the position of the rotor when phase A is energized. As long as phase A is energized, the rotor will be held stationary.

.e

ee

ex

When phase A is switched off and phase B is energized, the rotor will turn 30 until two poles of the rotor are aligned under the north and south poles established by phase B.

cl u

si

Fig.4

ve

.b l

og

sp ot

.c o

48 By repeating this pattern, the motor will rotate in a clockwise direction. The direction of the motor is changed by reversing the pattern of turning ON and OFF each phase. The disadvantage of this design for a stepper motor is that the steps are generally quite large (above 15). Multistack stepper motors can produce smaller step sizes because the motor is divided along its axial length into magnetically isolated sections, or stacks.

Result:

.e

ee

ex

cl u

si

ve

.b l

og

sp ot

.c o

49
EXPT. NO.: DATE:

DETERMINATION OF TRANSFER FUNCTION OF SEPRATELY EXITED DC GENERATOR


AIM: To determine the transfer function of separately exited generator. APPARATUS REQUIRED: Ammeter MC (0-1A), (0-10A) Ammeter MI (0-5A),(0-50mA) Voltmeter MC (0-300V) Voltmeter MI (0-300V) Rheostat 1000 / 1A Rheostat 50 / 5A Auto Transformer 1 230V/270V THEORY:

Where Vf(s)- Excitation Voltage Rf, Lf - Field resistance & Inductance If(s) - Field Current Kg Induced emf constant in V/Amp Ll Total load Inductance Rl Total load resistance Kg can be obtained by conducting open circuit test Rf, Lf, Ra, Lf can be found out by voltmeter- Ammeter method

IL(s)/Vf(s) = Kg /(Rf+sLf)(Rl+sLa)

.e

The transfer function is

ee

ex

cl u

si

ve

.b l

The transfer function of a separately excited generator can be represented in block diagram format as shown below

og

sp ot

.c o

50 DC GENERATOR Circuit Diagram

DETERMINATION OF Ra : Circuit Diagram

3 4 5 6 7 8 9 10

1 2

.e

Tabulation S.No Va (V)

ee

ex

Ifa (A)

cl u

si

ve

Ra =Va/Ia(

.b l
) Mean value of Ra =

og

sp ot

.c o

51

DETERMINATION OF Rf : Circuit Diagram

1 2 3 4 5 6 7 8 Determination of Lf Circuit Diagram

.e

ee

ex

cl u

si

ve

.b l

og

sp ot

S.No

Vf (V)

If (A)

Rf =Vf/If(

.c o

52 Tabulation S.No Vf (V) 1 2 3 4 5 6 7 8 9 10

If (A)

Zf (

)=Vf/If

Mean value of Zf =

Circuit Diagram

.e

ee

ex

cl u

si

Determination of La

ve

.b l

og

sp ot

.c o

53
Tabulation

S.No 1 2 3 4 5 6 7 8 9 10

Va (V)

Ia (A)

Za (

)=Va/Ia

Open circuit characteristics

.e

ee

ex

cl u

si

ve

.b l

og

sp ot

.c o

Mean value of Za =

54

PROCEDURE: Determination of Kg: 1. 2. 3. 4. 5. 6. 7. 8. 9. The connections are made as shown in fig. DPST switch is closed The motor is started with help of starter The motor is brought to the rated speed by adjusting the motor field rheostat. The drives the generated at rated speed. Note down the field current If and the open circuit voltage Eo. By adjusting the Rf, the field current is increased in convenient steps up to the rated field current. In each step the readings of Eo and If are noted. Throughout the experiment the speed is maintained at constant A plot of Eo Vs If is drawn by taking If on X axis and Eo on Y-axis. A tangent to the linear portion of the curve is dran through the origin. The slope of this line ,Eo Vs If gives Kg.

RESULT:

.e

ee

Where f= supply frequency (50Hz)

ex

cl u

1. Give the connection as shown in fig to measure Ra & Rf and note down the V & I 2. To measure La &Lf give the connection as shown in fig. 3. Apply an AC voltage & measure the field reactance Zf & armature reactance Za. 4. Calculate Lf= Sqrt(Zf2 Rf2) /2f 5. Calculate La = Sqrt(Za2 Ra2) /2f

si

ve

.b l

og

V-A method to obtain Ra, Rf, La & Lf

sp ot

.c o

55
EXPT. NO.: DATE:

STUDY OF SYNCHROS
AIM: To study the characteristics of Synchros. APPARATUS REQUIRED:

The constructional features and schematic diagram of a synchro transmitter and receiver is shown in fig.1. Let an AC voltage Vc(t) = Vr Sin t be applied to the rotor of the synchro transmitter. The applied voltage causes a flow of a magnetizing current in the rotor coil, which produces a sinusoidal time varying flux directed along its axis and distributed nearly sinusoidally in the air gap along the stator periphery. Because of transformer action, voltages are induced in each of the stator coils. As the air gap flux is sinusoidally distributed, the flux linking any stator coil is proportional to the cosine of the angle between the rotor and stator coil axis, and so is the voltage induced in the stator coil. Thus, we see that synchro transmitter acts like a single-

Fig.1 Constructional Features of Synchro Transmitter

.e

ee

ex

cl u

si

ve

.b l

A Synchro is an electro-magnetic transducer used to convert an angular position of a shaft into an electrical signal. It is commercially known as a Selsyn or an Autosyn. The basic element of a synchro is a synchro transmitter whose construction is very similar to that of a 3 phase Alternator. The stator is of concentric coil type, in which three identical coils are placed with their axis 120 apart, and is star connected. The rotor is of dumb bell shaped construction and is wound with a concentric coil. AC voltage is applied to the rotor winding through slip rings.

og

sp ot

.c o

THEORY:

56 phase transformer in which the rotor coil is the primary and stator coil is the secondary.

Vs1 = K Vr Sint Cos ( + 120 ) ---------------------------- (1)

The three terminal voltages of stator are

Vs1s2 = Vs1 - Vs2 =3 KVr Sin( + 240 ) Sin t -----------------------(4)

When = 0, from equations (1), (2) and (3), it is seen that the maximum voltage is induced in the stator coil S2 , while it follows from the equation (6) from that the terminal voltage Vs3s1 is zero . This position of the rotor is defined as the electrical zero of the transmitter and is used as reference for specifying the angular position of the rotor. The input to the synchro transmitter is the angular position of its rotor shaft and the output is a set of 3 single-phase voltages given by equations (4) to (6). The magnitude of these voltages is function of the shaft position. The outputs of the synchro transmitter are applied to the stator windings of a synchro control transformer. The rotor of the control transformer is cylindrical in shape so that the air gap is practically uniform. The system acts as an error detector. Circulating currents of the same phase but of different magnitude flow through the two sets of stator coils. This results in the establishment of an identical flux pattern in the gap at the control transformer as the voltage drop in resistances and leakage reactances of the two sets of stator coils are usually small. The voltage induced in the

Vs3s1 = Vs3 - Vs1 =3 KVr Sin() Sin t

.e

Vs2s3 = Vs2 - Vs3 = 3 KVr Sin( + 120 ) Sin t ----------------------(5) -----------------------(6)

ee

ex

cl u

si

Vs3 =K Vr Sint Cos ( + 240 ) ----------------------------(3)

ve

Vs2 = K Vr Sint Cos ( ) ----------------------------------(2)

.b l

og

sp ot

Let Vs1, Vs2 & Vs3 be the voltage induced in the stator coils S1,S2 and S3 with respect to the neutral. Then, for the rotor position of the synchro transmitter shown in the fig. 2 where the rotor axis makes an angle with the axis of the stator coil S2

.c o

Fig .2 Schematic Diagram of Synchro Transmitter

57 control transformer rotor is proportional to the cosine of the angle between the two rotors () and is given by E(t) = K1 Vr Cos Sin t When =900, the voltage induced in the control transformer is zero. This position is known as electrical zero position of the control transformer.

3. Plot the variation in output position with respect to the input position.

Tabulation 2: 1. Give excitation to the rotor winding. 2. Measure the output voltage across S1-S2, S2-S3 and S3-S1 of stator windings for different rotor positions. 3. Plot the voltage Vs. angle characteristics.

.e

Tabulation 1: 1. Give connections as given in the circuit diagram. 2. Vary the input position and note the output position.

ee

ex

PROCEDURE:

cl u

si

Fig. 3 Synchro Error Detector

ve

.b l

og

sp ot

.c o

58 TABULATION: I Sl.No Input Output Error position position (degrees) (degrees) (degrees) 0 30 60 90 120 150 210 240 270 300 330 180

1 2 3 4 5 6 7 8 9 10 11 12

S.No 1 2 3 4 5 6 7 8 9 10 11 12

30 60 90

RESULT:

INFERENCE:

120 150 180 210

240 270 300 330

.e

ee

ex

cl u

Input angle (degree) 0

Vs1 - Vs2 (V)

si

ve

TABULATION : II

.b l
Vs2 - Vs3 (V) Vs3 - Vs1 (V)

og

sp ot

.c o

59

EXPT. NO: DATE :

DESIGN OF COMPENSATOR NETWORKS


AIM: To design a compensator network for the process given in the Process Control Simulator. APPARATUS REQUIRED:

THEORY:

Practical feedback control systems are often required to satisfy design specification in the transient as well as steady state regions. This is not possible by selecting good quality components alone (due to basic limitations and characteristics of these components). Cascade compensation is most commonly used for this purpose and design of compensation networks figures prominently in any course in automatic control systems. In general, there are two situations in which compensation is required. In the first case the system is absolutely unstable and the compensation is required to stabilize it as well as to achieve a specified performance. In the second case the system is stable but the compensation is required to obtain the desired performance. The systems which are of type 2 or higher are usually unstable. For these systems, lead compensator is required, because the lead compensator increases the margin of stability. For type 1 and type 0 systems stable operation is always possible. If the gain is sufficiently reduced, in such cases, any of three components viz. Lag, Lead, Lag Lead must be used to obtain the desired performance. The simulation of this behavior of the Lead Lag Compensator can be done with the module (VLLN OI). An electronic Lead - lag network using Operational amplifiers is given figure 1. C2

.e

ee

C1

ex

cl u

si

ve

.b l
R2 -

og

sp ot
R3

.c o
R4 + R1 +
Fig.1 LEAD -LAG NETWORK USING OPERATIONAL -AMPLIFIER

60 The transfer function for this circuit can be obtained as follows : Let Z1 = R1 C1

The second op-amp acts as a sign inverter with a variable gain to compensate for the magnitude. The transfer function of the entire system is given by G(j) = ( R4 R2/ R3 R1 ) (1+R1C1s) / (1+R2 C2 s) G(j) = ( R4 R2/ R3 R1 ) ( 1+T122) / ( 1+T222 ) where T1 = R1 C1 ; T2 = R2 C2 = angle G(j) = - tan-1(T1) tan-1(T2). Thus steady state output is For an input =X sint, Yss(t) =X (R4 R2/ R3 R1) (( 1+T122) / ( 1+T222 ))sin(wt tan-1 T1 tan-1 T2 ) From this expression, we find that if T1 > T2, then tan-1 T1 tan-1 T2 > 0. Thus if T1 > T2 , then the network is a LEAD NETWORK. If T1 < T2 , then the network is a LAG NETWORK.

Angle to be compensated = 70

Hence, the values of T1 and T2 are chosen from which values of R1 ,C1 , R2 and C2 can be determined . For example, T1 =R1 C1 = 10 ; If C1= 1F, then R1 = 10 M .

These values produce a phase lead of 70 which is the desired compensation angle. Nominal Value for R1 =1 M R2 =20 K C1 = 0.1 F C2 = 0.01 F

T2 = 0.003 .

solving for T2

T2 = 0.003 = R2 C2 then C2 =1 F, and hence R2 = 3 M .

.e

70 - tan-1 (2 * * 20 * 10) tan-1 (2 * * 20 *T2)

ee

T1 = 10, then substituting in above equation

ex

= tan-1 (2 f * T1) tan-1 (2 f * T2)

cl u

si

Frequency of sine wave = 20 Hz

ve

DETERMINATION OF VALUES FOR ANGLE COMPENSATION:

.b l

og

sp ot

.c o

61 PROCEDURE: 1. 2. 3. 4. 5. Switch ON the power to the instrument. Connect the individual blocks using patch chords. Give a sinusoidal input as the set value . Measure the amplitude and frequency of the input signal. Measure the amplitude and phase shift of the output signal with respect to the input sine wave using CRO. 6. Draw the magnitude versus frequency plot and phase versus frequency plot. R2 and C2 to compensate for the phase shift of the output signal. 9. Now include the compensation block in the forward path before the

verify for compensation. 11.

Draw the magnitude versus frequency plot and phase versus frequency

ee

ex

Table 1 (for the process without compensation): S.No. Input Output Gain (dB) 20 log(Vo/Vin) Phase shift ()

Freq (Hz)

.e

Voltage(V)

cl u

plot for the designed compensator.

si

ve

.b l

10.

Now measure the phase shift of the output signal with the input and

og

process using patch chords.

sp ot

8.

Connect the components at the points provided.

.c o

7.

Using the technique explained previously, calculate the values of R1, C1,

62 Table I1 (for the process with compensation): Vin = V

S.No.

Input

Output

Gain (dB) 20 log(Vo/Vin)

P Phase shift ()

Freq (Hz) Voltage(V)

A Amplitude of input sine wave (V)

INFERENCE:

RESULT :

.e

ee

Phase shift (Degrees)

ex

F Frequency of the input sine wave (Hz)

cl u

si

ve

.b l

og

sp ot

.c o

63

EXPT. NO.: DATE:

STUDY OF P, PI, PID CONTROLLERS


AIM: To study the P, PI, PID controller using MATLAB software . APPARATUS REQUIRED:

The output of the controller is proportional to input U(t) = Kp e(t) E(t) = error signal U(t) controller out[put Kp = proportional constant It amplifies the error signal and increases loop gain. Hence steady state tracking accuracy , disturbance signal rejection and relative stability are improved. Its drawbacks are low sensitivity to parameter variation and it produces constant steady state error.

Proportional + Integral Control: The output of the PI controller is given by t U(t) = Kp [ e(t) + (1/Ti ) e(t) dt ] 0 where Kp is the proportionality constant and Ti is called the integral time. This controller is also called RESET controller. It introduces a zero in the system and increases the order by 1. The type number of open loop system is increased by 1

.e

ee

ex

cl u

si

Proportional control:

ve

The transient response of a practical control system often exhibits damped oscillation before reaching steady state value. In specifying the transient response characteristics of control systems to unit step input, it is common to specify the following i) Delay Time(Td) ii) Rise time(Tr) iii) Peal time( Tp) iv) Max. overshoot (Mp) v) Settling time( Ts)

.b l

og

sp ot

.c o

THEORY:

64 It eliminates steady state error. Damping ratio remains same. Increase in order decreases the stability of system.

Proportional + Integral Control + Differential Control: The output of a PID controller is given by t U(t) = Kp [ e(t) + (1/Ti ) e(t) dt + Td de(t)/dt ] 0 The PID controller introduces a zero in the system and increases the damping. This reduces peak overshoot and reduces rise time. Due to increase in damping, ultimately peak overshoot reduces. The stability of the system improves. In PID controller, all effects are combined. Proportional control stabilizes gain but produces steady state error. Integral control eliminates error. Derivative controller reduces rate of change of error.

PROCEDURE:

1. Give the step input to the system selected and obtain the response using CRO. 2. For the obtained response (S-shaped curve), draw a tangent at the inflection point and find its intersection with the time axis and the line corresponding to the steady-state value of the output. 3. Find the dead time L where the tangent cutting X- axis, and the time constant T which is specified in model graph. 4. From the value of L and T, find the value of Kp, I and d settings by using the following formulas: Kp = 1.2(T/L) , I = 2L and d = 0.5L. 5. Connect the unknown system in closed loop with the help of a PID controller and substitute all those values obtained in the previous step.

.e

Where

ee

U(s)=Kp (1+(1/si)+sd) Kp= proportional gain constant I= integral time constant. d= Derivative time constant.

ex

In presenting the various tuning techniques we shall assume the basic control configuration, wherein the controller input is the error between the desired output and the actual output. This error is manipulated by the controller (PID) to produce a command signal for the plant according to the relationship.

cl u

si

ve

Proportional-integral-differential (PID) controllers are commonly employed in process control industries. Hence we shall present various techniques of tuning PID controllers to achieve certain performance index for systems dynamic response. The technique to be adopted for determining the proportional, integral and derivative constants of the controller depends upon the dynamic response of the plant.

.b l

og

sp ot

TUNING OF PID CONTROLLERS

.c o

65 6. Simulate the system with a step input and view the response using CRO. 7. Comment on the response obtained using controller.

(I)General Block Diagram

(II)Block Diagram for P Controller

(III)OP Amp P Controller Using Inverting Amplifier

.e

ee

ex

cl u

si

ve

.b l

og

sp ot

.c o

66 (IV) Block Diagram For PI Controller

(VI) Block Diagram Of PID Controller

.e

ee

ex

cl u

si

ve

.b l

og

sp ot

.c o

(V) PI Controller Using Op-Amp

67 Block Diagram Of Closed Loop Control Using PID Controller M(s) R(s) E(s)
PID(KP,Ti,Td )
Transfer Function

C(s)

C(s)

.e

ee

ex

cl u

si

ve

INFERENCE:

.b l

og

sp ot

.c o

RESULT: