1|P a g e ReportNo:12M008/09_01
1. Test item: Proof test 2. Test place: Vina Offshore Yard 3. Specification: (1) Pipe Fitting (2) Out Site Diameter (D) (3) Thickness (T) (4) Tensile Strength (S) (5) Heat No. (6) Test Accordance with Tee 1 Sch-STD 33.4 mm 3.38 mm 514 MPa (74549.4 Psi) 312545 ASME B16.9-2007
5. Test result: - When the hydraulic pressure is at bar, the fitting was deformed (see photo 1-1). - When the hydraulic pressure is over bar (at bar, see photo 1-2), the fitting was deformed and no burst. - When the hydraulic pressure is at bar (see photo 1-3) the fitting was deformed and no burst.
2|P a g e ReportNo:12M008/09_01
Photo 1-1
Photo 1-2
3|P a g e ReportNo:12M008/09_01