Joe Zaccari
Military Programs Manager
Corfin Industries LLC
603-893-9900 phone
jzaccari@corfin.com
www.corfin.com
Presentation Outline :
Whiskers
Stress
Intermetallic Formation
Abrasion of Plating
Factors in Whisker Development
Plating Chemistry/Process
– Electroplating Current Density
Higher Current Density --> Higher Residual Stress
– Tin Grain Size and Shape
Submicron Grains
“Matte” vs. “Bright” Finish
– Use of “Brighteners” and Presence of Impurities
– Plating Thickness
>0.5 µm and <8 µm more prone
– Alloy composition
Pure Sn, Sn-Cu, Sn-Bi, and rarely Sn-Pb
Substrate (Including Base Metal and Barrier Plating
Layers)
– Material (Copper, Brass, Nickel, others)
– Substrate Preparation (Stamped, Formed, Annealed)
Relay Leads
Standard Dual In-Line Package (DIP) IC, Leads are copper based with
"pure matte tin plated finish" (confirmed via SEM/EDS).
Solderability Issues
Oxidation
Reflow
How Tin Plated lead forming differs
from Solder Coating
Lead Form After Plating
– Defects such as, poor solder joint quality and
degraded long-term reliability can result from
forming the leads after the plating has been applied.
– Exposed base material at the device “toe” when the
leads are trimmed to length.
Toe fillet quality
– Micro-cracks in the plating.
Oxidation of lead surface.
Exposed
Base Metal
Formed Lead
12,000x
Magnification
3,000x
Magnification
BSE Image
Mitigation Strategies
Use as is (case-by-case evaluation)
Arc with high voltage
Matte plating
Conformal coat
Hot solder dip
Mitigation Strategies
Use as is
– Assumptions required
Arc w/ high voltage
– Components may not survive
– Subjective process
Matte plating
– Eliminates one potential problem but evidence
exists that whiskers occur in all tin and tin alloy
plated finishes.
– Matte plating is still susceptible to oxidation.
Conformal coat
– Shown to be ineffective in some cases
Use as is
– When a case-by-case assessment is used some
level of assumptions required.
No ability to simulate assembly and operation
environmental factors for test purposes.
Down stream alteration of operational parameters would be
problematic.
– Assumption is too subjective for high reliability
applications.
Conformal coat
– Shown to be ineffective in some cases
– Difficult to determine acceptable application
Are spaces between fine pitch leads filled?
Matte plating
– Evidence exists that whiskers occur in all tin and tin
alloy plated finishes.
Strict process control required.
– How to establish “out of control” parameters
Matte plating is still susceptible to oxidation.
Bridging
Icicles
Solder Build-up
Solder Build-up
Solder Build-up
Width
0.006 X X
0.13 X X X
0.19 X
0.23 X X X
0.3 X X
Environmental Impact
– Hazardous waste
Process water is only waste product
– Lead levels in waste water is many time below levels
allowable into municipal sewer systems.
– Hazardous waste generation is in the “household”
classification.
– All other materials are recycled
Solder ( tin & lead)