Key words
Refrigerant characteristics
Refrigerant Type Composition Boiling Point Behavior Pressure at 54.5 (kPa) GWP (Global warming potential) ODP (ozone depletion potential) R407C R410A R32/R125 (50/50) -51.4 near azeotrope 3,406 2000 R22 R22 (100) -40.8 --2,151 1700 R32/R125/R134a (wt%) (23/25/52) -43.6 zeotrope 2,262 1700
0.055
Conclusion :Now more and more products with R410A units will be needed in the future;
THE NEW CHOICE FOR INTELLIGENT LIFE
Best
Better
Good
Features brief
DC inverter
Saving Energy
Environment
Intelligent
Friendly
Comfortable
HRV
Healthy
Social Needs
Various Indoor Unit Space Saving Cabinet Maximum Piping Length Connectable Indoor Units Quantity Demand Control Centralized Control
End User
8HP 10HP
18HP 20HP
34HP 36HP
Combination
Standard Combination & Connection number of indoor units
Total Capacity
8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP 24HP 26HP 28HP 30HP 32HP 34HP 36HP 38HP 40HP 42HP 44HP 46HP 48HP 2 2 1 1 1 1 1 2 1 1 2 2 2 3 1 1 1 1 2 1 1 1 2 1 1 2 1 1 1 Combined Mothod 8HP 1 1 1 1 1 10HP 12HP 14HP 16HP
64 64
7
2.2
9
2.8
12
3.6
16
4.5
18
5.6
24
7.1
28
8.0
30
9.0
38
11.2
48
14.0
72
12.0
88
25.7
kW
Ave.Cool i ng 4.20 4.00 3.80 3.60 3.40 3.20 3.00 2.80 2.60
Hai er DK V*V2
A v e . COP ( CDU o n l y )
4. 00 3. 90 3. 80 3. 52 3. 86 3. 80
3. 553. 51 3. 46 3. 403. 383. 37 3. 41 3. 40 3. 34 3. 333. 353. 333. 37 32 3. 28 3. 263. 253. 22 3. 303. 28 3. 24 3. 223. 22 3. 253. 21 3. 25 233. 18 3. 21 203. 20 203. 20 18 18
8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48
system (HP)
Many Energy Many Energy Saving Technology Saving Technology Adopted Adopted
comparison
Absolute DC Technology
DC Inverter Scroll Compressor
Permanent magnet rotor
It does not require the induced current because the permanent magnet is use for the rotor, it means there is no current loss. Without electromagnetic noise and rotor wastage, the Reluctance DC motor of compressor is much more efficient than AC motor, and comfortable to use.
Ferrite Magnet
Neodymium Magnet
The Reluctance DC motor of compressor utilize powerful neodymium magnets that are 10 times more powerful than conventional magnets.
Absolute DC Technology
DC Fan Motor
The speed of the wide range DC fan motor can be adjusted from 0 r/min to 1000 r/min Compared to conventional AC motors, a DC fan motor offers greater operating efficiency, especially during low-speed rotation. The efficiency could be 90%.
Mitsubishi. Elec
The capacity of single compressor can be adjusted from 2kW to 45kW.Wide range inverter compressor satisfy the customers various demands.
The system could realize absolute inverter control, it can improve the adjustive precision, avoid frequent halt and temperature fluctuations, it is reliable for use.
10HP
comparison
There are one inverter compressor and two none-inverter compressor in it THE NEW CHOICE FOR INTELLIGENT LIFE
Efficient Structure
New Big Diameter Aviation Fan
Using the aviation motor airscrew theory, invent the new big diameter aviation fan
air resistance reduce 5%, increase heat exchange efficiency 3% lower noise level decrease 1dB(A) THE NEW CHOICE FOR INTELLIGENT LIFE
Efficient Parts
Sub-Cooling Heat Exchanger
Sub-cooling heat exchanger utilize little refrigerant to cool most of refrigerant in system ,and make it a further cooling, improve sub-cooling degree of refrigerant , it can avoid energy loss due to refrigerant flash evaporating when it go through PMV.
Effect of Sub-cooler
It will increase cooling capacity by 46%, reduce refrigerant circulation amounts and decrease flowing resistance by 55%,so that it can increase the efficiency of system.
Efficient Exchanger
Effect of Super-cooling Circuit
Using the power resistance to detect the position of rotor in compressor, so that the operation current of compressor close to sine wave easily.
With 180-degree vector driving control technology, the compressor could operate steadily and improve its efficiency, so that the system can save energy furthest.
Non-halt Defrosting
Non-stop Defrosting
convention state of defrost status of non-halt defrost
The system will begin to defrost when the power of 4-way valve is cut off, and continue to heating after defrost over immediately. Without non-inverter compressor, the system could reduce the time that spend on balancing pressure when the non-inverter compressors start-up and stop. It will ensure your use because of defrost time shorten. The absolute-inverter system could rise frequency directly and steadily, offer you more comfort. THE NEW CHOICE FOR INTELLIGENT LIFE
50 40 30 20 10 0 -10 -20
15.5 WB
cooling heating
-5 DB
-20 WB
Manual-Mode:
You can set the time to make the mode start and stop
Silence First Capacity First
The human design ensures the quiet and comfort sleeping environment at night THE NEW CHOICE FOR INTELLIGENT LIFE
HRV Technology
Heat Reclaim Ventilation
Operation Principle
Adopting HRV unit , outside fresh air could be introduced to the indoor unit , at the same time , indoor dirty air exhausted to outside, and keep the indoor heat loss, this will keep indoor air comfortable , dehumidified and clean.
Central Controller
Wired Controller
Precise Control
PID Control
P : Proportion Adjustment I : Integral Adjustment D : Differential Adjustment
PID control adjust the output of compressor and the open degree of PMV ,balance the indoor refrigerant flow , realize the linear output ,creates a comfortable environment. The temperature could be control precisely with the range of 0.5 . THE NEW CHOICE FOR INTELLIGENT LIFE
Variable Control
Variable Control Mode
You can choose
Wireless remote controller (Standard for the units except for duct type )
Variable Control
Wireless remote controller (Optional)
Max 16 units All the indoor units can work in the different modes
Max 64 units All the indoor units can work in different modes Monitor all modes of indoor units Malfunction code display & save Realize fire alarm when catch fire On/Off the unit with the outside timer signal
BMS System
H-CACS Management System
Intelligent Control
Accurately Power Distribution
Haier Power Distribution System distribute the total power consumption which calculate by pulse ammeter to individual indoor units , and the distribution according to the refrigerant flux in every indoor unit which calculated by indoor unit operation time & the open degree of indoors PMV.
Compare to conventional control method, Haier Power Distribution System make the distribution more precisely and reasonably, it could avoid the users dissension because of electrical fee.
Human Control
Preferential Control
With the human design , you can set different preferential steps of some indoor units according to the room functions , so that it will ensure that the most important room gains adequate cooling and heating air in using midseason.
Room Card
The ON/OFF card can control the system with a room card in the remote place. It is widely adopted in the building, hotel or other commercial space. Could save energy effectively ,convenient for management THE NEW CHOICE FOR INTELLIGENT LIFE
Flexible Installation
Long Piping Length & Large Drop
Total 300M refrigerant piping length Max.150M refrigerant piping length (actual length is175M) Max. 50M height drop between indoor and outdoor units Max. 15M height drop between indoor units
Easy Installation Improvement of Installation Work 1 Most Compact SizeRealized by Inverness Fan
Squar e
Cut
2000
1390
16HP AV16NMVERA
Squar e Cut
2
3000 30HP
2780
AV32NMVERA
Easy Transporation
Modularized design & less space needed
NEW 10HP 16HP
1.5m2
Apporx.30% reduction
The outdoor units space only occupy 0.74m2 and 1.04m2,it can transport with elevators, save lots of transport cost and time. The outdoor units can installed in different floors, save the whole system test time.
Easy Installation
Concise System
MRV System Chiller System
Comparing with chiller water system, without filter, stop valves, accessory etc, MRV units refrigerant piping greatly reduce the system installation work and save a lot of protection &clean work.
Normal Wiring Design
A super wiring system is used to enable shared use of the wiring between indoor & outdoor units and the central control wiring. With a simple wiring operation ,the only work you need to do is connect the central controller to the outdoor unit directly if central controller adopted. THE NEW CHOICE FOR INTELLIGENT LIFE
Reliable Compressor
Advanced high efficiency Compressor
With a patented compressor ,it can avoid being less of oil when compressor running at low rotate speed ,and discharging overmuch oil at high speed. It is reliable to use
Mitsubishi. Elec.
Absolute inverter
Reduce Starting Current
Non-inverter NonStarting Current Wave inverter
Reliable Operation
Duty Cycling of Outdoor Units
The outdoor units make no difference between primary unit and secondary unit. For the system which consist of more than one unit ,the operating turns of units will be changed every 24 hours
Duty cycling of outdoor units could balance the operation hours and life of each outdoor unit in order to prolong the systems life.
Backup Operation
If one outdoor unit malfunctions in the system more than 16HP appeared ,the other units provide emergent operation until repair achieved
The backup operation could avoid the system closing down totally due to one unit malfunction happens ,it is quite reliable to use.
Reliable Operation
Safe Start-Up Technology
Principle of Start-up Technology
NO.1: Standby NO.2: running
Outdoor unit solenoid valve
status SV 2 OF F
No.1
SV 9 ON SV1 1 ON SV 2 ON
No.2
SV 9 ON SV1 1 OFF
unit close down, the other units will pump the refrigerant in it into running system circle, in order to avoid the liquid refrigerant enter compressor when the halting unit start next time.
Start-up Technology could avoid compressor being damage because of liquid refrigerant, and ensure that the system has enough circulation amounts of refrigerant. THE NEW CHOICE FOR INTELLIGENT LIFE
Reliable Operation
Intelligent Oil-Equalizing Technology (equalize oil without non-halt operation)
Principle of Oil Equalizing
Outdoor unit solenoid valve
Oil to No1 Oil to No2 SV 2 ON OF F
No.1
SV 8 OF F ON SV 9 ON ON SV1 2 OF F OF F SV 2 OF F ON
No.2
SV 8 ON OF F SV 9 ON ON SV1 2 OF F OF F
The system adopt oil storage tank and advanced control technology to realize oil-equalizing between several units on real-time.
It makes oil-equalizing control independently, so it could ensure that each of compressor has equal quantities of oil , and at the same time, the capacity outputs isnt affected.
Reliable Operation
Efficient Oil Separator
The efficiency of new designed oil separator can up to 96%.
Mitsubishi. Elec.
It can separate oil from refrigerant efficient, avoid compressor being frayed owing to lack of oil.
Failure Code
10 Haier (407C
C-MRV
Haier (410A
MRV II-C
Daikin R410A)
VRV
Mitsubishi E (R410A)
City Multi Y-S eries
AU96NFTBH AV10NMV A ERA 0.97 304 28.0 2.37 31.5 2.91 60 60 12.7 28.6 100 50(40) 0.74 235 28.0 3.80 31.5 3.95 58 53 9.52 22.2 150(175) 50(40)
RXYQ -10M 0.71 230 28.0 3.11 31.5 3.38 58 9.5 22.2 150(175) 50(40)
PUHYP250YGM-A 0.83 233 28.0 3.60 31.5 4.13 57 49 9.52 22.2 150(175) 50
kW kW dB(A) dB(A) mm mm m m
Outdoor model Installation Space Net Weight Nominal Cooling Capacity COP Nominal Heating Capacity COP Sound Level Cool/Heat Nighit-Shift Liquid Gas Oil Max Total Piping Length Lift between I.U. and O.U. (O.U. is lower) Pipe Size
m2 kg kW kW dB(A) dB(A) mm mm mm m m
Outdoor model Installation Space Net Weight Nominal Cooling Capacity COP Nominal Heating Capacity COP Sound Level Cool/Heat Nighit-Shift Liquid Gas Oil Max Total Piping Length Lift between I.U. and O.U. (O.U. is lower) Pipe Size
Unit Model Installation Space Net Weight Nominal Cooling Capacity COP Nominal Heating Capacity COP Sound Level Cool/Heat Nighit-Shift Liquid Gas Oil Max Total Piping Length Lift between I.U. and O.U. (O.U. is lower) Pipe Size
m2 kg kW kW dB(A) dB(A) mm mm mm m m
m2 kg kW kW dB(A) dB(A) mm mm mm m m
Software Support
Piping Design Software
This software supply a solution of piping deisgn ,can help the designer select the right material lists, basic wiring diagram and control wiring diagram etc. ,most important thing is to save lots of time during design procedure;
Software Support
Example
System piping diagram
Software Support
On site testing software
The software can be used on the system installation and testing, greatly improves the installation and maintenance efficiency, comveinience for the installer & maintenance technicians.
Maintenance convenience
MRV II Supplier
No. Brand origin Company Brand name Tehnology
1
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
China
Japan Japan Japan Japan Japan Japan Japan Korea Korea China China China China China China Thailand
Haier
Daikin Mitsubishi electric Hitachi Toshiba Carrier Sanyo MHI Fujitsu general Samsung LG Midea Gree Shinco Tsinghua Tongfang Aux TCL Saiji Denki
MRV
VRV City Multi Set Free SMMS ECO-i KX4 Air stage DVM Multi V MDV GMV SDV Shrv ARV MAV
Inverter
Inverter Inverter Inverter Inverter Inverter Inverter Inverter Digital Scroll Digital Scroll Digital Scroll & Inverter Digital Scroll Digital Scroll Digital Scroll Digital Scroll Digital Scroll Digital Scroll
SRV
Items
Outdoor unit Indoor unit series
Conclusion
More outdoor choice MRV II Indoor units have 47 specifications ,more choice than old CMRV series;
11 12
16 10