45 Applicable Standard 1 Noise Suppression Left/ For USA Canada Europe China Russia Heat Oil twist Right Left For UL NFPA70/NFPA79 cUL/CSA Resis Resis Resis Vibra /Right Cable Twisted tance tion Ben Carrier <PS>E Flexible Flexible CE CCC GOST-R tance tance Shield Pair AWM MTW TC AWM Resis ding cord cord tance Japan 1
VCT200X
VCT222
60
VCT222X
VCT360
VCT531BX
75
VCT531BXS
VCT531Z
Low-temperature flexibility, allowing use for cable connection in low-temperature warehouse and mobile cable connection in cold region For use in cable connection to general-purpose equipment, motor-driven tools and submerged pumps Mat type, allowing use for cable connection to general-purpose equipment Oil resistance, allowing use for cable connection to machine tools that tend to cause oil splashing during operation Oil resistance/noise resistance, allowing use for cable connection to machine tools that tend to cause oil splashing during operation 45left/right vibration resistance, allowing use for cable connection to indoor/outdoor mobile electrical equipment Braided conductor/bending resistance, allowing use for control cable connection to cable carriers, robots and other similar equipment Braided conductor/bending resistance/noise resistance, allowing use for control cable connection to cable carriers, robots and other similar equipment Fine conductor/bending resistance, allowing use for cable connection to cable carriers, robots and other similar equipment
60
VCT531UX
VCTF22
VCTF36
300V
VCTF36SB
VCTF23NXX
VCTF43Z
KVC-36 Weak Current Electric Circit 105 KVC-36SB UL, cUL 80 KVC-36SBT
2 2
Twist resistance, allowing use for cable connection by hanger suspension Flexibility, allowing use for cable connection to various types of small-sized electrical equipment and machine tools Oil resistance, allowing use for cable connection between equipment components and cable connection to machine tools that tend to cause oil splashing during operation Oil resistance, allowing use for cable connection between equipment components and cable connection to machine tools that tend to cause oil splashing during operation Oil resistance/noise resistance, allowing use for cable connection to machine tools that tend to cause oil splashing during operation 45left/right vibration resistance, allowing use for mobile cable connection to machine tools and other similar equipment 45left/right vibration resistance/noise resistance, allowing use for mobile cable connection to machine tools and other similar equipment Reinforcement cord containing conductor/bending resistance, allowing use for cable connection to cable carriers, robots and other similar equipment Flexibility, allowing use for control cable connection to machine tools Noise resistance/flexibility, allowing use for control cable connection to machine tools Noise resistance/flexibility, allowing use for control cable connection to machine tools
KVC-43BX 75 KVC-43BXS
KDF
KDF-SBL
CE-362
1 1
Europe, CCC 300/500V Global Standard Cable 1 UL, cUL 600V <PS>E 300V
1 1
CE-531XX
1 1
CE-531XXSB
1 1
Braided conductor/bending resistance, allowing use for cable connection to cable carriers (low-speed) Noise resistance/braided conductor/bending resistance, allowing use for cable connection to cable carriers (low-speed) Fluorocarbon resin insulation/bending resistance, allowing use for cable connection to cable carriers and robot arm swinging parts Fluorocarbon resin insulation/noise resistance/bending resistance, allowing use for cable connection to cable carriers and robot arm swinging parts Fluorocarbon resin insulation/bending resistance, allowing use for cable connection to cable carriers Fluorocarbon resin insulation/bending resistance/noise resistance, allowing use for cable connection to cable carriers Flexibility, allowing use for internal/external cable connection to electrical equipment and cable connection under oil environment Noise resistance/flexibility, allowing use for internal/external cable connection to electrical equipment and cable connection under oil environment 45left/right vibration, allowing use for internal/external cable connection to electrical equipment and cable connection under oil environment Noise resistance/45left/right
CE-531NZ
CE-531NZSB
CE-362(BE)
Europe 300/300V UL, cUL 300V Europe, CCC 300/500V or 450/750V UL, cUL 300 or 600V 3
vibration resistance, allowing use for internal/external cable connection to electrical equipment and cable connection under oil environment Reinforcement cord containing conductor/bending resistance, allowing use for cable connection to cable carriers and robots Reinforcement cord containing conductor/noise resistance/bending resistance, allowing use for cable connection to cable carriers and robots Flexibility, allowing use for internal/external cable connection to electrical equipment and cable connection under oil environment Flexibility, allowing use for internal/external cable connection to electrical equipment and cable connection under oil environment Heat resistance, allowing use for internal cable connection to equipment NFPA70/79 compliance/heat resistance, allowing use for internal cable connection to equipment NFPA70/79 compliance/oil resistance/heat resistance/flame resistance, allowing use for power cable connection to electrical equipment and cable connection to cable trays NFPA70/79 compliance/oil resistance/heat resistance/flame resistance,
KR-STO/TC
KRC-352(BE)/TC
KIC-35
UL, cUL 80
KIC-35(BE), KIC-35(R)
KIC-45
FA Network Cable 4
3 UL13 PLTC/CL2 1
Curl Cord
60
CVF-U
allowing use for internal/external cable connection to electrical equipment and cable connection to cable trays Reinforcement cord containing conductor/bending resistance, allowing use for cable connection to cable carriers and robots Oil resistance, allowing use for internal/external cable connection to electrical equipment and cable connection under oil environment Oil resistance, allowing use for internal/external cable connection to electrical equipment and cable connection under oil environment 45left/right vibration resistance/oil resistance, allowing use for internal/external cable connection to electrical equipment, cable connection under oil environment and mobile cable connection For DeviceNet For CC-Link, CC-Link/LT For PROFIBUS For AS-Interface For EtherNet/IP, PROFINET, FL-Net and other industrial Ethernet, as well as Ethernet cable connection to locations requiring oil resistant/noise resistant cable connection High extensibility/bending resistance/cold resistance, allowing use for control cable connection to industrial robot and other machine parts extending, contracting and swinging
1 The cable is subject to limitation of applicable sizes and grades for each relevant standard. For details, refer to the relevant product page. 2 The cable is of twisted pair design depending on the size. For details, refer to the relevant product page. 3 For details, refer to the relevant product page. 4 For details regarding FA network cable, refer to the relevant product page.