1 Introduction

Network management is the general term used to define the process by which one (or more management systems) controls and manages a network e.g. composed of transport and access equipment. In order to accomplish the network management, the communication must be established between each network element and its corresponding management system. The collective term for all these communication paths is "DCN - Data Communication Network". The management data are transported via DCN communication paths. These management data are messages from management systems to network elements and vice versa. The data could be alarms protection switching events, performance data, configuration commands measurements

Purpose: This document describes the management features of the NSN IP Radio equipments in the most common DCN design scenarios. The DCN network scenarios of this document are typical and just shall illustrate the available DCN Network Elements. The NEs may be used in many other combinations and mixtures. Being dependent from different network topologies, it is impossible to describe all the inter-working cases. . Scope: The Scope of the guideline includes: Dimensioning: This document contains information about MW NEs and describes how they are connected. It explains their function within the DCN Scenarios. Inter-working: The goal of this document is to provide a short guideline for the inter-working between the different types of MW Network Elements

The following is not-within the scope of this guideline: Detailed planning aspects: The NEs may be used in many other combinations and mixtures. Being dependent from different network topologies, it is impossible to describe all the possible DCN Scenarios. Optimization

2 Product & feature description


2.1 Inter-working Sral/Sral XD
As a rule, the interfaces used to connect the SRAL XD to the SRAL are the Dext or the Q-Lan / V-Lan Ethernet interface (the SRAL must be provided with the D-External card or with a Dual-Q Adapter). From SVR 3.4, the F interface can be also used to connect the SRAL XD to the SRAL, but it has the drawback of a lower connection speed compared to Ethernet and D-External interfaces. For SRAL XD Plug-in SVR 3.5 and onwards, the VBUS interface can be also used to connect the SRAL XD to the SRAL. The connection speed of the different interfaces is reported here below: The connection speed of the different interfaces is reported here below: 1. 2. 3. SRAL F Interface: 19,2 Kbit/s SRALXD F Interface: 38,4 Kbit/s D-External Interface: 64 Kbit/s

4. VBUS Interface: 128 Kbit/s (only for SRAL XD Plugin SVR 3.5 and onwards) 5. 6. SRAL Ethernet Interface: 10 Mbit/s SRALXD Ethernet Interface: 10/100 Mbit/s

In the common networks, the gateway/grooming stations are generally provided with Routers and Dual-Q Adapters, then the Ethernet Interface is used. In the remote stations no additional devices are commonly present, then the D-external or the V-BUS Interface will be preferred. F-interface is generally used for single spurs appended to existing Network Elements where no extra-hardware is required. For connection through Ethernet interface a HUB/LAN-Switch with both RJ45 and BNC interfaces should be provided (the SRAL must be equipped with a Q-Adapter/DualQ-Adapter card). For connection through D-Ext channel a V.11 cable (Siemens coded) should be used between the SRAL and the SRAL XD (the SRAL must be equipped with D-external card). For connection through F-interface a RS232 cable (Siemens coded) should be used between the SRAL and the SRAL XD (no need for extra hardware).

Here below some examples of Network Topology about the requirement to use in case of a station with or without Router/DualQ-Adapter and a final example for a general network topology.

2.2 Station with a Router/DualQ-Adapter

Figure 1 - Station with Router/Dual Q-Adapter and Multiport Hub RJ45 BNC (1)

Router

SRAL XD and SRAL are connected through a HUB/LAN-Switch with both RJ45 and BNC interfaces. SRAL must be equipped with Q-Adapter/DualQ-Adapter card (or connected through V-Bus to a stand-alone DualQ-Adapter equipment). The IP Addresses of SRAL XD, Router and DualQ-Adapter Ethernet interfaces must belong to the same sub-network. The IP addresses of DualQ-Adapter V-Bus interface and SRAL controller must belong to the same sub-network, different from the Ethernet previous one. The IP Addresses of NEs connected through radio link must belong to different subnetworks

RJ 45 Cable

The following picture describes a connection through V-BUS cable that is not possible because of the use of the V-BUS and Ethernet Interfaces on the SRAL XD at the same time.

Router

RJ 45 Cable

SRALXD 3.5

SRALXD 3.5 Station 2

V-BUS Cable

SRAL
Station 1

SRAL
Station 3

Figure 2 - Solution not applicable

When no MultiPort HUB RJ45/BNC Converters are available, it is still possible to connect SRAL and SRAL XD (rel. 3.5) devices through a V-BUS cable as described in the following picture. This connection, however, is deprecated: SRAL directly connected to the RJ45/BNC Converter, in fact, must forward the traffic generated by the other device(s) and this could overload the SRAL.

SRALXD 3.5
V-BUS Cable

SRALXD 3.5 Station 2

Router

RJ 45 Cable

Converter RJ45/BNC

SRAL
BNC Cable DualQ-Ad.

SRAL
Station 3

Station 1

Figure 3 - Station with Router/Dual Q-Adapter with converter RJ45/BNC (1)

SRAL XD and SRAL are connected through a V-BUS cable (for SRAL XD 3.5 only).

SRAL must be equipped with Q-Adapter/DualQ-Adapter card (or connected through V-Bus to a stand-alone DualQ-Adapter equipment). The IP addresses of Router and DualQ-Adapter Ethernet interfaces must belong to the same sub-network. The IP Addresses of DualQ-Adapter V-Bus interface, SRAL and SRAL XD must belong to the same sub-network, different from the Ethernet previous one. The IP Addresses of NEs connected through radio link must belong to different subnetworks

2.3 Remote Station without DualQ-Adapter


Using the D-External Interface:
Station 1

SRALXD

SRALXD

To Supervision System

V11 cable

D-External

SRAL

SRAL
Station 3

Station 2

Figure 4 - Remote Station without DualQ-Adapter using Dext

Connect SRAL XD and SRAL using a V11 cable (coded by Siemens). The SRAL must be equipped with the optional D-External card. This optional card is housed in the same slot of the DualQAdapter card. In the SRAL XD use one of the two D-Connectors (named User/Dext) available on the front of the shelf. The chosen channel must be configured via software using the IP SRAL Compatible option in the related NE Parameters field. The IP Addresses of SRAL XD and SRAL connected through the V11 cable must belong to different sub-networks as for the radio link rules. The IP Addresses of NEs connected through radio link must belong to different sub-networks.

2.4 General Network scenario


In a general network topology, its possible to have stations with or without DualQAdapter. Here below an example of inter-connections between SRAL XD and SRAL NEs using different interfaces (Ethernet, D-external, V-BUS or F-Interface).

Figure 5 - General Network scenario (1)

Summary Management Centre: Default gateway or static routes are necessary on NetViewer server in order to manage the NEs.

Station 1: The IP Addresses of SRALXD, DualQ-Adapter (Eth. interface) and Router Ethernet interface must belong to the same sub-network. Station 4: The IP Addresses of SRALXD and SRAL, connected through V11 cable, must belong to different sub-networks as for the radio link rules. Station 6: The IP Address of the SRAL XD connected by F-interface to the SRAL must be equal to the SRAL IP Address plus one in case they are in same subnet. The Ethernet interface of the SRAL XD must be disabled. The speed of F interface must be set to 19.2 Kbit/s (both NEs). Station 8: The IP Addresses of SRALXD (rel 3.5) and SRAL must belong to the same sub-network.