The majority of pharmaceutical products have to enter the bloodstream in order to be effective. They can be taken orally, via the intestine, by injection or infusion. In addition, there are other special methods that are grouped under the collective term new drug delivery systems. These include, for instance, transdermal therapeutic systems (TTS), whereby the active pharmaceutical ingredient is absorbed by the skin, or the subcutaneous injection, whereby the drug is administered almost pain-free, using injection equipment. An alternative method for taking in the active pharmaceutical ingredient is the micronised powder method. In this case, a predetermined dose of powder is inhaled into the lungs (pulmonary) or over the nasal mucous membrane (nasal) and distributed in the bloodstream. While the production processes for injections, tablets and infusion solutions are undergoing technical development and are available on the market, the procedural method and its large-scale technical implementation also have to be developed when a new drug delivery system is introduced, besides the actual development of the medicament itself and its testing. In this respect, knowledge of the behaviour of the medicament plays just as much a role as the technical know-how for setting up a production machine. Harro Hfliger Verpackungsmaschinen GmbH has made a name for itself in this very sector during the past 10 years by developing and implementing production methods and possible solutions for its customers as regards manufacturing and packing pharmaceutical products. At Hfliger, the competence necessary for handling pharmaceutical products is combined with highly technical expertise in the sectors for process monitoring and control engineering. If one takes the example for processing different types of micronised powder, it is possible to demonstrate how the obstacles arising during the development of a new procedure can be overcome successfully. The ability to process micronised powder and the
BUSINESS BRIEFING: PHARMAGENERICS 2003
selection for a certain dosing procedure depends largely on the physical properties of the respective powder involved. These properties are defined by its flow behaviour, ability to be compressed, roughness and adhesive behaviour. Expert knowledge on mechanics and electrical engineering is therefore no longer sufficient by any means for bringing powder filling machines onto the market successfully today. In addition, the variety of differing methods of drug delivery is increasing tremendously due to the rapid development of the products. It is a fact that the number of patents for inhalable products increased sixfold from 1976 to 1999 alone in the US. This is mainly based on the fact that the nasal and pulmonary forms of intake are far less expensive than the customary injection therapy and cause the patient far less pain. Apart from this, the argumentation no first-pass metabolism and the suppression of the pulsed absorption profile speak out in favour of the
Figure 1: Powder Properties
pulmonary or nasal intake of active pharmaceutical ingredients. If one takes a closer look at the development of the dry powder inhalers (DPIs), it can be determined that, due to the place where the powder becomes effective, the size of the particles is becoming progressively smaller in order to enable better absorption by the body. The trend towards continued reduction in the size of the particles and thus a continual reduction in the dosage quantities has a decisive influence on the physical behaviour of the powder. The distribution of the particles and their size and roughness thus largely determines the flow behaviour, which, in turn, is of crucial importance during the transport of the active pharmaceutical ingredient from the inhaling device to the lungs and, to the same degree, also from the dosing unit of the powder filling machine to the device. Whereas the investigation of the behaviour of a medication drug in the human body is the task of
Figure 2: Development Process
pharmaceutical research, it is the task of those developing the machine to provide installations that are aligned optimally to the process. In the sector for powder processing machines, this means that the manufacturer of the machine must know exactly what the properties of the powder are, in order to select the optimum dosing procedure to suit it. The focus of a powder filling machine as regards its function is therefore normally on the procedure to be selected. At Harro Hfliger Verpackungsmaschinen GmbH, the powder in question is therefore examined thoroughly before its filling process is decided on and developed. This, for instance, includes the following investigations: particle size distribution; particle size; adhesion force; particle geometry; particle roughness; and powder density.
3 4 5
6
BUSINESS BRIEFING: PHARMAGENERICS 2003
A nominal output per machine of 2,700 inhalers per hour is equivalent to a turnover of 121,500/hour. Correspondingly, the focus lies on the powder in the starting phase of a new project. The respective dosing procedure is selected by taking the classification of the powder as a basis. As a basic rule, a differentiation is made here as regards dosing. Whereas, colloquially, we only use the term dosing, the experts differentiate between filling and dosing. The term filling is used for a container (blister cavity, plastic cartridge, etc.) being filled with the product. If this is carried out 100%, the filling volume of the container represents the filling quantity. Here, one should consider the ambient variables (including temperature and humidity) and the properties of the powder (including the degree of compaction) that have to be kept constant. Although it sounds simple, in theory, to produce constant conditions, problems often occur here in practice. These problems can be, for example: tolerance in the powder production process; variations in the room humidity; uneven distribution of the powder density; and variations in the moisture of the powder, etc.
Not until a powder has been defined and classified can the selection of one or several suitable dosing systems be made. Once the selection has been made, further steps towards developing the optimum production process can be taken. Here, it is decisive that the pharmacist has authoritative involvement in the development and also plays a role in deciding what steps should be taken next. These are, for instance, questions as to whether experiments with differing dosing procedures should be undertaken or whether experimental set-ups should possibly be designed and installed. Depending on the complexity of a development project of this kind, the step-by-step procedure (see Figure 2) is of decisive advantage, as opposed to ordering a machine to be developed immediately. This process clearly focuses on dialogue and communication with the pharmacist. As already mentioned, the output of the machine is restricted to the flow behaviour of the powder. A simple sum in economics underlines the significance of the powder dosing station. Let us suppose that a selling price of 45 can be reached for one device. The device contains 30 single doses, each having a filling quantity of 13mg, i.e. 390mg: 45 @ 30 doses = 1.50 per dose.
Figure 3: Dosing Procedure
Even at the stage of producing the powder, these parameters have to be kept within very tight
Figure 5: Infeed and Device Core Orientation for the Disassembly of Components
tolerances, which, however, does not automatically mean that the powder density can change during the subsequent filling procedure. This is dependent, for instance, on the time between the production and filling and on the mechanical treatment of the powder during the filling procedure. Using constructive means, influence can thereby be brought to bear at an early stage. Sensor technology can therefore be employed to keep the powder filling height in the dosing container almost constant or the flow velocity can be influenced by the geometrical arrangement. By observing the effects of possibilities like these, the degree of efficiency of a plant can be increased considerably. To ensure the appropriate dosing procedure, Harro Hfliger Verpackungsmaschinen GmbH not only analyses the powder, but also tests its dosing capability. For this purpose, there are differing dosing systems available for selection and, if necessary, new testing equipment can be set up. The respective powder undergoes a sample dosing procedure at the powder laboratory, thus enabling the result of the analysis to be documented. When dosing the powder, the filling quantity is determined by the dosing volume of the dosing tool. Flow behaviour, especially in the case of inhalant powder, is largely influenced by the adhesion force between the powder particles (van der Waals forces). Once the adhesion forces have been determined qualitatively, the dosing system can be selected.
BUSINESS BRIEFING: PHARMAGENERICS 2003
Figure 6: Powder Filling of Chamber and Compaction for a Defined Powder Density