1. CONTRACTOR TO PROVIDE AND OBTAIN APPROVAL FOR A SITE MITIGATION AND CONSTRUCTION MITIGATION PLAN.

SUCH PLANS SHALL ADDRESS ALL ACTIVITIES AND SHALL INCLUDE, BUT IS NOT LIMITED TO, VEHICLE PARKING, MATERIAL STORAGE, STREET CLEANING, WORK HOURS, ETC. CONTRACTOR TO MAINTAIN A CLEAN JOB SITE AND MINIMIZE NOISE AND DUST. WORK TO BE CONFINED TO THE HOURS SPECIFIED IN THE CONSTRUCTION MITIGATION PLAN. 2. HEATING SYSTEM SHALL BE GAS-FIRED FORCED AIR. CONTRACTOR IS RESPONSIBLE FOR GAS SYSTEM DESIGN, INCLUDING DUCT SIZING AND LAYOUT. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR PROVIDING HEAT LOSS CALCULATIONS AND ENERGY ANALYSIS AND SUBMITTING THEM. 3. CONTRACTOR TO PROVIDE MAKE, MODEL, BTU's, APPROVAL LISTINGS, AND EFFICIENCY OF FURNACE AND ANY ADDITIONAL EQUIPMENT TO BUILDING DEPARTMENT. 4. CONTRACTOR TO PROVIDE APPLIANCE I.C.B.O. NUMBERS TO BUILDING DEPARTMENT AND INSTALLATION GUIDES FOR GAS FIREPLACE INSERTS. 5. THE CONTRACTOR SHALL PROVIDE GAS LINE SPECIFICATIONS, PLANS, AND CALCULATIONS TO BUILDING DEPARTMENT IF THE GAS PIPE LINE SYSTEM IS OVER 4 oz. PRESSURE. CONTRACTOR SHALL ALSO INCLUDE REGULATOR VALVE SPECIFICATIONS AND SHOW PLACEMENT ON PLANS. 6. CONTRACTOR TO PROVIDE THE NUMBER OF BACKFLOW PREVENTORS TO BE INSTALLED IN THIS STRUCTURE. 7. INSPECTIONS ARE REQUIRED FOR ALL STUCCO AND EIFS SYSTEMS. PROVIDE ICBO EVALUATION REPORT (OR EQUAL) FOR ANY SUCH SYSTEM USED. IRC R109.1.5

Nichols, Steve and Kris


LOT 53, Dutch Fields Midway, UT 84049

DRAWING INDEX Sheet Number Sheet Name


A1.1 A1.2 A2.0 A2.1 A2.2 A2.3 A3.1 A3.2 A4.1 A5.1 A6.1 E1.1 E1.2 E1.3 S1.0 S1.1 S1.2 S1.3 S1.4 S1.5 S1.6 S1.7 SITE PLAN SITE DISTURBANCE PLAN ARCHITECTURAL NOTES LOWER LEVEL PLAN MAIN LEVEL PLAN UPPER LEVEL FRONT/REAR ELEVATIONS SIDE ELEVATIONS 3D VIEWS - EXTERIOR AREA PLANS BUILDING SECTIONS ELECTRICAL PLAN - LOWER ELECTRICAL PLAN - MAIN ELECTRICAL PLAN - UPPER STRUCTURAL NOTES FOOTING / FOUNDATION PLAN FRAMING PLAN - MAIN FLOOR FRAMING PLAN - UPPER FLOOR FRAMING PLAN - ROOF SHEAR PLANS DETAILS DETAILS

BUILDER: BUILDERS SIGNATURE:_____________________________________ DATE:__________________________________________

DESIGNER:
Log Craft, Inc. 385 West Airport Rd. Heber City, Utah 84032 Ph: (435) 657-2120 Fx: (435) 654-7555

ENGINEER OF RECORD:
PARK ENGINEERING, LLC 90 West 200 South, Suite #1 Heber City, Utah 84032 Ph: (435) 654-1456

Park Engineering

NICHOLS RESIDENCE

Log Craft, Inc. 385 West Airport Rd. Heber City, Utah 84032 Ph: (435) 657-2120 Fx: (435) 654-7555

DEFERRED SUBMITTAL NOTES

N 89 41' 16" E 176.19'


SETBACK 30' - 0"

GENERAL SITE NOTES


GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. PROVIDE CON. SPLASH BLOCKS @ ALL DOWNSPOUT LOCATIONS. INSTALL EXPANSION JOINTS @ 40'-0" MAX IN CONC. WALKS & CONTROL JOINTS @ 5'-0" MAX. ALL WALK INTERSECTIONS TO HAVE A 24" RADIUS. ALL STUMPS, ROOTS, AND ORGANIC MATERIAL SHALL BE REMOVED FROM THE SOIL IN THE BUILDING AREA TO A DEPTH OF 12". 6. ALL EARTH FILL TO RECEIVE CONC. FLOORS, WALKS, DRIVES, ETC. SHALL BE SETTLED AND TAMPED TO 90% COMPACTION. 7. APPROVED NUMBERS FOR ADDRESS SHALL BE PROVIDED FOR ALL NEW BUILDINGS IN SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROADWAY FRONTING THE PROPERTY. 8. SURFACE WATER SHALL DRAIN AWAY FROM HOUSE AT ALL POINTS. DIRECT THE DRAINAGE WATER TO THE STREET OR TO AN APPROVED DRAINAGE COURSE, BUT NOT ONTO NEIGHBORING PROPERTIES. THE GRADE SHALL DROP A MINIMUM OF 6 INCHES WITHIN THE FIRST 10 FEET. -IRC R401.3. 9. FINISH GRADE CUTS & FILLS THAT HAVE A SLOPE GREATER THAN 2:1 REQUIRE A SOILS REPORT. 10. ROCK RETAINING WALLS HIGHER THAN 4' AND A COMBINATION OF ROCK RETAINING WALLS THAT CREATE A SLOPE GREATER THAN 2:1 REQUIRE ENGINEERING. 11. SURVEYOR & CONTRACTOR TO PROVIDE A CERTIFICATE OF ELEVATION WHEN REQUIRED. 1. 2. 3. 4. 5.
6' M AX

10' - 0"

10' - 0"

30'-0" x 50'-0" ACCESSORY BUILDING ENVELOPE


40' - 0"

30' - 0"

FILTER FABRIC FASTENED TO POST

2"x2"x48" MIN. HARDWOOD POST

15' - 0" SETBACK

2'-6"

15' - 0" SETBACK 56' - 6"

DUTCH FIELDS LOT 53


100'-0" x 80'-0" BUILDING ENVELOPE

SHEET FLOW

LINE SIDE AND BOTTOM OF TRENCH WITH BOTTOM OF FILTER FABRIC AND BACKFILL W/ EXCAVATED SOIL

ISOMETRIC VIEW
PROPERTY LINE ELECTRIC METER
N 0 57' 05" E 234.58'

SECTION VIEW

DRIVEWAY
42' - 6"

AD RO ED V PA
33' - 0"

PERPENDICULAR TO PAVED ROAD


20 IN. 'M

INSTALLATION: 1. LAYOUT SILT FENCE 5'-10' BEYOND TOE OF SLOPE WHERE POSSIBLE. 2. ALIGN THE FENCE ALONG THE CONTOUR AS CLOSE AS POSSIBLE.

PROPOSED HOUSE
43' - 0"

3. USE MACHINERY TO DIG TRENCH THAT DOES NOT CREATE A TRENCH LARGER THAN DESIRED. 4. PLACE POSTS A MAXIMUM OF 6' O.C. & DRIVE 2' INTO GROUND. ANCHOR USE 1" TO 2-1/2" COURSE AGGREGATE TRENCH TO BE 8"x8" 5. CUT FABRIC TO REQUIRED WIDTH, UNROLL ALONG LENGTH OF BARRIER AND DRAPE OVER BARRIER. SECURE FABRIC TO STAKES W/ STAPLES, OR

13' - 0" MIN.

37 13 42' 7. 42 26 " W '

GAS METER

80' -0 "

22' - 0"

EQUIVALENT, WITH TRAILING EDGE EXTENDING INTO ANCHOR TRENCH. PLACE FILTER FABRIC BENEATH AGGREGATE IF PROJECT HAS A DURATION OF 3 MONTHS OR MORE 6. BACKFILL TRENCH OVER FILTER FABRIC TO ANCHOR.

30' 0" SET BAC K

61' -0 "

50' -0 "

21 '-

6"

SECTION VIEW
INSTALLATION:

RUNOFF FLOW

DUTC

H VAL LEY D

RIVE
25' -0 "

63 3 10 9' 21 8.4 "W 1'

15 '0" SE TB AC K

25' -0 "

1. INSTALL AT ANY POINT OF INGRESS OR EGRESS AT A CONSTRUCTION SITE WHERE ADJACENT TRAVELED WAY IS PAVED. 2. CLEAR AND GRUB AREA AND GRADE TO PROVIDE SLOPE FOR DRIVEWAY. IF ADJACENT TO WATERWAY, USE A MAXIMUM SLOPE OF 2%. 3. COMPACT SUBGRADE AND PLACE FILTER FABRIC IF REQUIRED. 4. PLACE COURSE AGGREGATE, 1 TO 2-1/2", TO A DEPTH IF 4". MAINTENANCE: 1. INSPECT DAILY FOR GRAVEL LOSS OF SEDIMENT BUILDUP. 2. INSPECT ADJACENT ROADWAY FOR SEDIMENT DEOPSIT, CLEAN IF NECESSARY. 3. REPAIR ENTRANCE AND REPLACE GRAVEL AS REQUIRED TO MAINTAIN GOOD WORKING CONDITION. 4. EXPAND STABILIZED AREA AS REQUIRED TO ACCOMODATE TRAFFIC, AND TO PREVENT EROSION OF DRIVEWAY. INSTALLATION:

ATTACHMENT OF 2 FENCES
1. PLACE THE END OF THE POST OF THE SECOND FENCE INSIDE THE END POST OF THE FIRST FENCE. 2. ROTATE BOTH POSTS AT LEAST 180 IN A CLOCKWISE DIRECTION TO CREATE A TIGHT SEAL WITH THE FABRIC MATERIAL. 3. DRIVE BOTH POSTS 24" INTO THE GROUND AND BURY TAIL OF FILTER MATERIAL.

Site Plan
SCALE: 1" = 40'-0"
COPYRIGHT 2010. ALL RIGHTS RESERVED BY LOG CRAFT, INC. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

SHEET TITLE

DRAWINGS FOR:

A1.1

SHEET NUMBER

SITE PLAN
DRAWN BY: CHECKED BY: DATE:

Nichols, Steve and Kris


LOT 53, Dutch Fields Midway, UT 84049
NOTE: THESE PLANS ARE A REFERENCE ONLY. CONTRACTOR TO VERIFY THAT ITS CONTENTS ARE CORRECT & MEET CURRENT BUILDING CODES PRIOR TO CONSTRUCTION.

385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555

NT

NT

03/03/11

2'-0"

124' - 6"

S 0 20' 13" E 175.03'

5596 FUTURE ACCESSORY BUILDING ENVELOPE


(APPROX. 1,200 sq. ft.)

GENERAL SITE NOTES

DUTCH FIELDS LOT 53


5594

SLOPE GRADE AWAY FROM HOUSE IN ALL DIRECTIONS MIN. 6" DROP WITHIN THE FIRST 10'-0"

SHEET FLOW

SITE DISTURBANCE ENVELOPE PROPERTY LINE


(APPROX. 29,000 sq. ft.)

LINE SIDE AND BOTTOM OF TRENCH WITH BOTTOM OF FILTER FABRIC AND BACKFILL W/ EXCAVATED SOIL

ISOMETRIC VIEW
55 90

SECTION VIEW

DRIVEWAY
ALL REMAINING STORM DRAINAGE TO SLOPE TOWARD FRONT OF LOT
SE R.

AD RO ED V PA

PERPENDICULAR TO PAVED ROAD


20 IN. 'M

INSTALLATION: 1. LAYOUT SILT FENCE 5'-10' BEYOND TOE OF SLOPE WHERE POSSIBLE. 2. ALIGN THE FENCE ALONG THE CONTOUR AS CLOSE AS POSSIBLE.

PROPOSED HOUSE
USE 1" TO 2-1/2" COURSE AGGREGATE

3. USE MACHINERY TO DIG TRENCH THAT DOES NOT CREATE A TRENCH LARGER THAN DESIRED. 4. PLACE POSTS A MAXIMUM OF 6' O.C. & DRIVE 2' INTO GROUND. ANCHOR TRENCH TO BE 8"x8" 5. CUT FABRIC TO REQUIRED WIDTH, UNROLL ALONG LENGTH OF BARRIER AND DRAPE OVER BARRIER. SECURE FABRIC TO STAKES W/ STAPLES, OR EQUIVALENT, WITH TRAILING EDGE EXTENDING INTO ANCHOR TRENCH. PLACE FILTER FABRIC BENEATH AGGREGATE IF PROJECT HAS A DURATION OF 3 MONTHS OR MORE 6. BACKFILL TRENCH OVER FILTER FABRIC TO ANCHOR.

3/4 "

4" L

DUMPSTER FIRE HYDRANT

AT .

88 55

95 LF 8

" SEW ER

WATER METER
MH #13
50 6
LF 8" PV C

55 86

DUTCH V ALLEY DRIVE

SECTION VIEW
INSTALLATION: 1. INSTALL AT ANY POINT OF INGRESS OR EGRESS AT A CONSTRUCTION SITE WHERE ADJACENT TRAVELED WAY IS PAVED. 2. CLEAR AND GRUB AREA AND GRADE TO PROVIDE SLOPE FOR DRIVEWAY. IF ADJACENT TO WATERWAY, USE A MAXIMUM SLOPE OF 2%. 3. COMPACT SUBGRADE AND PLACE FILTER FABRIC IF REQUIRED. 4. PLACE COURSE AGGREGATE, 1 TO 2-1/2", TO A DEPTH IF 4". MAINTENANCE: 1. INSPECT DAILY FOR GRAVEL LOSS OF SEDIMENT BUILDUP. 2. INSPECT ADJACENT ROADWAY FOR SEDIMENT DEPOSIT, CLEAN IF NECESSARY. 3. REPAIR ENTRANCE AND REPLACE GRAVEL AS REQUIRED TO MAINTAIN GOOD WORKING CONDITION. 4. EXPAND STABILIZED AREA AS REQUIRED TO ACCOMMODATE TRAFFIC, AND TO PREVENT EROSION OF DRIVEWAY. INSTALLATION: 1. PLACE THE END OF THE POST OF THE SECOND FENCE INSIDE THE END POST OF THE FIRST FENCE. 2. ROTATE BOTH POSTS AT LEAST 180 IN A CLOCKWISE DIRECTION TO CREATE A TIGHT SEAL WITH THE FABRIC MATERIAL. 3. DRIVE BOTH POSTS 24" INTO THE GROUND AND BURY TAIL OF FILTER MATERIAL.

RUNOFF FLOW

SILT FENCE

CONSTRUCTION TRAFFIC TO USE DRIVEWAY ENTRANCE

12 8

LF 12 "
SE W

PORTABLE TOILET
W AT ER

ATTACHMENT OF 2 FENCES

MA IN

IRRIGATION CONNECT

Site Disturbance Plan


SCALE: 1" = 40'-0"
COPYRIGHT 2010. ALL RIGHTS RESERVED BY LOG CRAFT, INC. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

ER

SHEET TITLE

DRAWINGS FOR:

A1.2

SHEET NUMBER

SITE DISTURBANCE PLAN


DRAWN BY: CHECKED BY: DATE:

Nichols, Steve and Kris


LOT 53, Dutch Fields Midway, UT 84049
NOTE: THESE PLANS ARE A REFERENCE ONLY. CONTRACTOR TO VERIFY THAT ITS CONTENTS ARE CORRECT & MEET CURRENT BUILDING CODES PRIOR TO CONSTRUCTION.

385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555

NT

NT

06/08/11

2'-0"

2 559

GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. PROVIDE CON. SPLASH BLOCKS @ ALL DOWNSPOUT LOCATIONS. INSTALL EXPANSION JOINTS @ 40'-0" MAX IN CONC. WALKS & CONTROL JOINTS @ 5'-0" MAX. ALL WALK INTERSECTIONS TO HAVE A 24" RADIUS. ALL STUMPS, ROOTS, AND ORGANIC MATERIAL SHALL BE REMOVED FROM THE SOIL IN THE BUILDING AREA TO A DEPTH OF 12". 6. ALL EARTH FILL TO RECEIVE CONC. FLOORS, WALKS, DRIVES, ETC. SHALL BE SETTLED AND TAMPED TO 90% COMPACTION. 7. APPROVED NUMBERS FOR ADDRESS SHALL BE PROVIDED FOR ALL NEW BUILDINGS IN SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROADWAY FRONTING THE PROPERTY. 8. SURFACE WATER SHALL DRAIN AWAY FROM HOUSE AT ALL POINTS. DIRECT THE DRAINAGE WATER TO THE STREET OR TO AN APPROVED DRAINAGE COURSE, BUT NOT ONTO NEIGHBORING PROPERTIES. THE GRADE SHALL DROP A MINIMUM OF 6 INCHES WITHIN THE FIRST 10 FEET. -IRC R401.3. 9. FINISH GRADE CUTS & FILLS THAT HAVE A SLOPE GREATER THAN 2:1 REQUIRE A SOILS REPORT. 10. ROCK RETAINING WALLS HIGHER THAN 4' AND A COMBINATION OF ROCK RETAINING WALLS THAT CREATE A SLOPE GREATER THAN 2:1 REQUIRE ENGINEERING. 11. SURVEYOR & CONTRACTOR TO PROVIDE A CERTIFICATE OF ELEVATION WHEN REQUIRED.

1. 2. 3. 4. 5.

6' M

AX

FILTER FABRIC FASTENED TO POST

2"x2"x48" MIN. HARDWOOD POST

2'-6"

GENERAL CONSTRUCTION NOTES


G1. G2. MAXIMUM RISE OF A STEP IS 73/4" AND THE MINIMUM RUN OF A STEP IS 10" (IRC R311.5.3). A CONTINUOUS HANDRAIL IS REQUIRED ALONG ONE SIDE OF STAIRWAYS & IS REQUIRED TO BE 34"-38" ABOVE THE NOSING OF THE STEPS. HANDRAIL MUST TERMINATE INTO A SAFETY TERMINAL. SIZE TO BE 1 3/8" MIN. - 2 1/2" MAX DIA. (IRC R311.5.6). ALL DECKS, PORCHES, OR STAIRS HIGHER THAN 30" ABOVE THE WALKING SURFACE REQUIRE A GUARD RAIL 36" HIGH W/ MAXIMUM OPENINGS LESS THAN 4" (INTERIOR OR EXTERIOR) (IRC R312.1). ANY ENCLOSED USABLE SPACE UNDER STAIRS ARE REQUIRED TO BE PROTECTED BY 1 HOUR FIRE-RESISTIVE CONSTRUCTION. (USE 1/2" GYP. BOARD)(R311.2.2) THE MINIMUM STAIRWAY HEADROOM HEIGHT VERTICALLY FROM NOSING LINE IS 6'-8" MIN (IRC R311.5.2). THE GARAGE MUST BE SEPARATED FROM THE DWELLING BY 1 HOUR FIRE-RESISTIVE CONSTRUCTION ON THE GARAGE SIDE, CEILING & THE BEARING WALLS. USE 1/2" GYP. BOARD. USE 5/8" TYP 'X' GYP. BOARD ON CEILING IF THERE IS HABITABLE SPACE ABOVE (IRC R309.2). ANY IGNITION UNIT ON ALL FURNACES & WATER HEATERS SHALL BE AT LEAST 18" ABOVE THE FLOOR IN THE GARAGE UNLESS FIRE RESISTIVE CONSTRUCTION IS USED TO SEPARATE THE UNITS FROM THE GARAGE (IRC G2408.2). THE DOOR SEPARATING THE GARAGE FROM THE DWELLING IS REQUIRED TO BE 1-3/8" SOLID CORE OR 20 MINUTE RATED, W/ APPROVED SELF CLOSING MEANS. ICE & SNOW SHIELD MUST BE USED OVER ALL EAVES AT LEAST 24" INSIDE THE HEATED WALLS IF SHINGLES ARE USED. ALL SHOWER AREAS TO BE FINISHED UP A MINIMUM OF 72" ABOVE SHOWER DRAIN WITH NONABSORBENT MATERIAL. PROVIDE FLOOR VENTILATION FOR CRAWLS SPACES AT 1 SQ. FT. PER 150 SQ. FT. OF UNDER FLOOR AREA, OR A RATION OF 1:1,500 WHERE THE SOIL IS COVERED WITH PLASTIC. VENTS TO BE ARRANGED ON AT LEAST TWO SIDES TO PROVIDE CROSS VENTILATION ON OPPOSING SIDES. IRC R408 & R402.2, EXCEPTION 2. PROVIDE 30" MINIMUM CLEARANCE FROM RANGE TOP TO COMBUSTIBLE MATERIALS. SIDE CLEARANCE SHALL BE AS SPECIFIED BY PERMANENT MARKINGS ON THE APPLIANCE. RANGE HOODS SHALL BE VENTED TO THE OUTSIDE BY SINGLE WALL PIPE HAVING A 1" MINIMUM CLEARANCE FROM COMBUSTIBLE MATERIALS (IRC R1901.1). UNLESS OTHERWISE SPECIFIED, ALL BASEMENT WINDOWS NOT FULLY 6" ABOVE FINISHED GRADE SHALL BE PROTECTED BY G.I. OR CONCRETE WINDOW WELLS. WINDOW WELLS TO BE DUG A DEPTH BELOW THE WINDOW SILL OF 10" TO ALLOW 1" AGGRAVATED GRAVEL TO BE 6" BELOW THE WINDOW SILL. FIREPLACE CHIMNEYS SHALL EXTEND 2'-0" ABOVE ANY ROOF LINE WITHIN 10'. ALL MASONRY CHIMNEYS SHALL HAVE TERRA COTTA FLUE LINERS & SHALL BE CAPPED W/ A 4" MINIMUM CONCRETE CAP. PROVIDE MINIMUM 100 sq. in. OF MAKE-UP AIR TO LAUNDRY ROOM (IRC G2439.4). THE MAXIMUM DRYER EXHAUST VENT LENGTH NOT TO EXCEED 15 FEET WITH NO MORE THAN (2) 90 DEGREE BENDS (IRC R1502.6)(M1502.6). INSULATE ALL DUCT WORK IN COLD AREAS. THIS IS BOTH HEAT RUNS & COLD AIR RETURN. IT ALSO INCLUDES GARAGES, CRAWL SPACES, & UNFINISHED BASEMENTS. (IECC 503.3.3.3) SIZE & CONSTRUCTION OF HEARTH TO BE PER MANUFACTURERS SPECIFICATIONS. ALL FOOTINGS SHALL BE PLACED ON UNDISTURBED EARTH AND BELOW FROST DEPTH (PER LOCAL CODE). TOPS OF FOUNDATIONS SHALL BE 8" MINIMUM ABOVE FINISHED GRADE. FINISHED GRADE SHALL HAVE A SLOPE AWAY FROM THE BUILDING OF 6" MINIMUM FOR THE FIRST 10' & A 2% SLOPE THEREAFTER. ALL DRAINAGE FROM LOT SHALL DRAIN INTO AN APPROVED DRAINAGE SYSTEM. SOLID BLOCKING TO BE PROVIDED BETWEEN TJI'S, RAFTERS, & TRUSSES OVER ALL BEARING WALLS AND BETWEEN OPEN BEARING STUDS. SUCH BLOCKING SHALL BE 2" MINIMUM THICKNESS AND FULL DEPTH OF TJI, RAFTER, OR STUD. ALL EARTH FILL TO RECEIVE CONCRETE FLOORS, WALKS, DRIVES, ETC. SHALL BE SETTLED AND TAMPED TO 90% COMPACTION. ENCLOSED ATTICS & ENCLOSED SPACES BETWEEN RAFTERS SHALL HAVE CLEAR CROSS-VENTILATION AREA TO THE OUTSIDE VENTS. VENTS SHALL PROVIDE AIR INTAKE TO MEET THE FOLLOWING CRITERIA: A. 1/150 OF ATTIC AREA, OR B. 1/300 OF ATTIC AREA IF CROSS VENTILATED W/ VAPOR BARRIER. ATTICS SHALL BE PROVIDED WITH AN ACCESS OPENING 22" x 30" W/ MINIMUM HEAD ROOM CLEARANCE ABOVE ACCESS OPENING OF 30". PROVIDE COMBUSTION AIR FOR ALL GAS APPLIANCES AT A RATE OF 1 SQ. INCH PER 4000 BTU's WHERE SPACE IS DIRECTLY COMMUNICATING WITH THE OUTDOORS, OR WHERE COMMUNICATING WITH THE OUTDOORS BY MEANS OF VERTICAL DUCTS. WHERE HORIZONTAL DUCTS ARE USED, EACH OPENING SHALL HAVE A FREE AREA OF AT LEAST 1 SQ. INCH PER 2000 BTU's. PROVIDE ONE DUCT OPENING IN THE TOP 12 OF THE ROOM AND ONE DUCT IN THE BOTTOM 12 OF THE ROOM (IRC R1703.2). WINDOW WELLS SHALL PROVIDE A MIN. NET CLEAR OPENING OF 9 sq. ft. W/ A MIN. DIMENSION OF 36". IF WINDOW WELL IS DEEPER THAN 44", PROVIDE PERMANENT LADDER. GARAGE ATTIC ACCESS DOOR TO BE 20 MIN. FIRE-RATED CONST. OR EQUIVALENT. PROVIDE A GAS SHUTOFF VALVE WITHIN 6' OF ALL GAS APPLIANCES. ALL SHOWER DOORS & GLASS IN SHOWER ENCLOSURES TO BE TEMPERED GLASS. PROVIDE AN ACCESS PANEL TO ALL JACUZZI TYPE TUBS. WATER HEATERS & EXPANSION TANKS TO BE TIED DOWN W/ SEISMIC STRAPS. STRAPS TO BE (2) 16 ga x 1" WIDE STRAPS LAGGED INTO (2) STUDS MIN. W/ 1/4" LAG SCREWS. (2) STUD WALL SHEATHED OR COVERED W/ GYP. BOARD OR SOLID BLOCKING MAY BE DONE AT STRAP HEIGHT. PROVIDE A MAX. 1" SPACE BETWEEN WATER HEATER AND WALL OR BLOCKS. GARAGE DOOR OPENERS, IF PROVIDED, SHALL BE LISTED IN ACCORDANCE WITH UL325.R309.6. EMERGENCY EGRESS SHALL BE PROVIDED FOR BASEMENTS & SLEEPING ROOMS. THE SILL HEIGHT SHALL NOT BE MORE THAN 44" ABOVE THE FLOOR. THE MINIMUM AREA SHALL NOT BE LESS THAN 5.7 sq. ft. HEIGHT SHALL NOT BE LESS THAN 24" & WIDTH SHALL NOT BE LESS THAN 20" (R310.1). C1. C2. C3. C4. C5. C6. C7. C8. C9.

GENERAL CONCRETE NOTES


ALL WORK SHALL BE IN STRICT ACCORDANCE WITH THE LATEST EDITION OF THE INTERNATIONAL BUILDING CODE (IBC), ACI 318-05, AND LOCAL ORDINANCES. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO POURING CONCRETE. ALL REINFORCING STEEL SHALL BE GRADE 60, AND BE PROPERLY TIED INTO PLACE PRIOR TO POURING CONCRETE. MIN. COMPRESSIVE STRENGTH f'c = 3000 PSI FOR SLABS, SUSPENDED SLABS, AND FOUNDATION WALLS, AND f'c = 3000 PSI MIN. FOR FOOTING (3000 PSI USED FOR DESIGN). ALL FOOTINGS SHALL BE 10" THICK AND PROPERLY FORMED UNLESS NOTED OTHERWISE. INTERIOR FOOTINGS MAY BE MONOLITHIC WITH SLAB. RECESS FOUNDATION AND POUR SLAB THROUGH, TYPICAL ALL EXTERIOR DOORS AND STORE FRONT TYPE WINDOWS, UNLESS NOTED OR DETAILED OTHERWISE. ALL EXTERIOR FOOTINGS SHALL BEAR BELOW FROST DEPTH (FIELD VERIFY). CONTRACTOR SHALL COORDINATE WITH MECHANICAL, ELECTRICAL, AND ARCHITECTURAL PRIOR TO POURING CONCRETE. PROVIDE SLEEVES, BLOCK OUTS, ETC. AS REQUIRED FOR PROJECT. PROVIDE ISOLATION JOINTS AROUND COLUMNS, SPREAD FOOTINGS, AND CONTROL JOINTS AS REQUIRED UNLESS SHOWN OTHERWISE ON PLANS. VERIFY LOCATIONS WITH ARCHITECT AND ENGINEER. ENGINEER SHALL NOT BE HELD LIABLE FOR EXCESSIVE CRACKING, ETC. OF FLOOR SLABS NOT PROPERLY JOINTED. DEPRESS SLAB AS REQUIRED IN AREAS OF CERAMIC TILE AND SPECIAL ENTRY MATS, ETC... (VERIFY WITH ARCHITECT). CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER PLACEMENT OF ALL ANCHOR BOLTS, HOLDDOWN ANCHORS OR STRAPS, ETC. INSTALL PER MANUFACTURER. ALL ANCHOR BOLTS SHALL HAVE 3 x 3 x 1/4" PLATE WASHERS (TYPICAL). CONTRACTOR SHALL PROVIDE ALL SHORING AS REQUIRED. BRACE WALLS AS REQUIRED UNTIL FLOOR FRAMING AND/OR SLABS ARE IN PLACE. TO MINIMIZE CRACKING OF SLABS ON GRADE, RECOMMEND USING #4 BARS @ 18" O.C. MIN. EACH WAY 1" CLEAR FROM TOP, OR 4 x 4 W2.9 x W2.9 WELDED WIRE MESH. VERIFY WITH OWNER. ENGINEER SHALL NOT BE HELD LIABLE FOR EXCESSIVE CRACKING, CURLING, ETC. OF FLOOR SLABS NOT REINFORCED. CONTRACTOR SHALL FIELD VERIFY ACTUAL SOILS CONDITIONS BY WAY OF A GEOTECHNICAL SOILS REPORT. COPY OF SOILS REPORT SHALL BE PROVIDED TO ENGINEER. ALLOWABLE SOIL BEARING PRESSURE USED FOR DESIGN = 2000 PSF. FOOTINGS SHALL BEAR ON UNDISTURBED NATURAL MATERIAL, OR ON PROPERLY PLACED ENGINEERED FILL. CONTRACTOR SHALL HAVE SOILS ENGINEER FIELD VERIFY. CONTRACTOR SHALL STEP FOOTINGS AND FOUNDATION AS REQUIRED. ANCHOR BOLTS TO BE 5/8" x 10" J-TYPE BOLT SPACED 32" O.C. PROVIDE A MINIMUM OF 18" BETWEEN FLOOR JOISTS & GROUND IN ALL CRAWL SPACES. ALSO PROVIDE A MINIMUM OF 12" BETWEEN GROUND AND THE BOTTOM OF GIRDERS OR BEAMS UNLESS PROPER MATERIAL IS BEING USED. PROVIDE PROPER VENTILATION TO ALL CRAWL SPACES. PROVIDE A VENT WITHIN 3 FT. OF EA. CORNER IN CRAWL SPACE. ALL CONCRETE SLABS TO BE A MINIMUM OF 3.5" THICK. ALL LUMBER IN CONTACT WITH CONCRETE MASONRY TO BE TREATED OR FOUNDATION GRADE REDWOOD. IRC R323. PROVIDE A 1/2" AIRSPACE AT TOP, SIDES & ENDS OF GIRDERS ENTERING EXTERIOR CONCRETE OR MASONRY WALLS UNLESS WOODS RESISTANT TO DECAY ARE USED. IRC R323. NO WOOD SHALL BE CLOSER THAN 6" TO EARTH UNLESS SEPARATED BY CONCRETE AT LEAST 3" THICK WITH AN IMPERVIOUS MEMBRANE INSTALLED BETWEEN THE EARTH AND THE CONCRETE. THIS INCLUDES DECKS AND SIDINGS.

G3. G4. G5. G6.

DATE

Nichols, Steve and Kris ARCHITECTURAL NOTES

G7. G8. G9. G10. G11.

C10. C11. C12. C13. C14.

G12.

G13.

C16. C17. C18. C19. C20. C21. C22. C23. C24.

G14. G15. G16. G17. G18. G19.

DRAWINGS FOR:

C15.

G20. G21. G22.

CHECKED BY: DRAWN BY:

GENERAL FRAMING NOTES


F1. F2. F3. F4. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE LATEST EDITION OF THE INTERNATIONAL BUILDING CODE (IBC), AND LOCAL ORDINANCES. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO STARTING CONSTRUCTION. ALL JOISTS, RAFTERS, AND HEADERS SHALL BE DOUGLAS FIR LARCH NO. 2 OR EQUAL. GLU-LAMINATED LUMBER SHALL BE 24F-V4 DF/DF. TJI'S OR EQUIVALENT MUST BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS AND SPECIFICATIONS. ALL JOISTS AND RAFTERS SHALL HAVE FULL-HEIGHT SOLID BLOCKING AT THEIR BEARING POINTS. CONNECT EA. BLOCK TO TOP OF WALL WITH SIMPSON A35 FRAMING ANCHORS RAFTERS TO HAVE SIMPSON H3 HURRICANE ANCHORS AT 48" O.C. MIN. SIMPSON H1 ANCHORS MAY BE USED AT EACH ROOF TRUSS OR RAFTER IN LIEU OF BOTH THE A35 ANCHOR AT EACH BLOCK AND THE H3 CLIP AT THE 48" O.C. THE A35 ANCHORS MAY BE OMITTED AT BLOCKING BETWEEN FLOORS IF SHEAR WALL EDGE NAILING IS PROVIDED AT THE SPLICE LOCATION IN THE SHEATHING AT THE DOUBLE TOP PLATE OF THE LOWER WALL (OPTION: SEE PLAN). ALL WOOD CONNECTION MUST CARRY THE CAPACITY OF THE MEMBER. CONTRACTOR IS RESPONSIBLE FOR CONNECTIONS. IF OTHER THAN STANDARD CONNECTIONS ARE REQUIRED, SEE PROJECT ENGINEER FOR ADDITIONAL ASSISTANCE. USE SIMPSON OR EQUIVALENT CONNECTIONS FOR WOOD TO WOOD. PREFABRICATED AND PRE-ENGINEERED TRUSSES CAN BE USED FOR THE ROOF AND/OR FLOORS. INSTALL PER MANUFACTURERS RECOMMENDATIONS AND SPECIFICATIONS. TRUSS MANUFACTURER SHALL DESIGN TRUSSES FOR ALL LOADS PER I.B.C., INCLUDING UNBALANCED SNOW LOADS, SNOW DRIFTING, SNOW BUILDUPS IN VALLEYS, AND ON EAVES, ETC. TRUSS MANUFACTURER SHALL RECOMMEND AND PROVIDE ALL REQUIRED TRUSS BRACING. ALL COLUMNS SHALL EXTEND DOWN THROUGH THE STRUCTURE TO THE FOUNDATION. COLUMNS SHALL BE BRACED AT EACH FLOOR LEVEL. COLUMNS SHALL BE AS WIDE AS THE MEMBER THEY SUPPORT IN ORDER TO PROVIDE FULL BEARING. ALL EXTERIOR WALLS SHALL BE SHEATHED WITH 7/16" APA EXP. 1 RATED SHEATHING OR EQUAL WITH 8d COMMON NAILS AT 4" O.C. EDGES AND AT 12" O.C. FIELD - BLOCKED, UNLESS NOTED OTHERWISE IN SHEAR WALL SCHEDULE. ALL ROOF SHEATHING SHALL BE 5/8" APA EXP. 1 RATED SHEATHING OR EQUAL WITH 8d COMMON ROOF NAILS AT 6" O.C. EDGES AND AT 12" O.C. FIELD. ALL FLOOR SHEATHING TO BE 3/4" THICK T&G SHEATHING GLUED AND NAILED WITH 8d COMMON NAILS OR EQUAL AT 6" O.C. EDGES AND AT 10" O.C. IN THE FIELD. ALL STRUCTURAL STEEL SHALL BE A36, PROPERLY PRIMED & PAINTED. THRUST SHALL BE ELIMINATED BY USE OF COLLAR TIES, OR JOISTS, (PROPERLY INSTALLED), AT ALL STICK FRAME AREAS, UNLESS SUPPORTED BY BEAMS. ALL VENEER SHALL BE ANCHORED AS PER THE 2006 IBC. ALL TIES SHALL BE CORROSION RESISTANT. SHEET METAL TIES SHALL BE 0.03" THICK BY 3/4" . WIRE TIES SHALL BE 0.148" IN DIA. (9 GAGE). TIES MAY NOT SUPPORT MORE THAN 2 SQUARE FEET OF WALL AREA AND MAY NOT BE SPACED MORE THAN 24" O.C. HORIZONTAL WALL TIES SHALL HAVE A LIP HOOK ON THE EXTENDED LEG THAT WILL ENGAGE OR ENCLOSE A HORIZONTAL JOINT REINFORCEMENT WIRE. JOINT REINFORCEMENT SHALL BE CONTINUOUS WITH BUTT SPLICES BETWEEN TIES PERMITTED. AS AN ALTERNATE TO APPROVED PAPER WITH SLUSH FILL, AN AIR SPACE OF 1" MIN. MAY BE MAINTAINED BETWEEN THE BACKING & THE VENEER, IN WHICH CASE SPOT BEDDING AT ALL TIES SHALL BE OF CEMENT MORTAR. VENEER MAY BE APPLIED WITH 1" MIN. GROUTED BACKING SPACE REINFORCED BY, BUT NOT LESS THAN 2" x 2" x 0.065" DIAMETER (16 GAGE) GALVANIZED WIRE MESH PLACED OVER WATERPROOF PAPER BACKING AND ANCHORED DIRECTLY TO STUD CONSTRUCTION. THE GALVANIZED WIRE MESH SHALL BE ANCHORED TO WOOD STUDS BY GALVANIZED STEEL WORE FURRING NAILS AT 6" O.C. WITH A 1.125" MIN. PENETRATION. THE GALVANIZED WIRE MESH MAY BE ATTACHED TO STEEL STUDS BY EQUIVALENT WIRE TIES. IF THIS METHOD IS APPLIED OVER SOLID SHEATHING, THE MESH MUST BE FURRED FOR EMBEDMENT IN GROUT. THE WIRE MUST BE ATTACHED AT THE TOP AND BOTTOM WITH NOT LESS THAN 8 PENNY COMMON WIRE NAILS. THE GROUT FILL SHALL BE PLACED TO FILL THE SPACE INTIMATELY AROUND THE WIRE MESH AND VENEER FACING. WEATHER-RESISTIVE BARRIER AND FLASHING INSPECTION REQUIRED ON EXTERIOR WALL ENVELOPE PER UTAH STATE AMEND. (SEC. R109.1.5) FIRE-BLOCK STUD SPACES AT SOFFITS, FLOOR & CEILING JOIST LINES AT 10' VERT. & HORIZ. ALSO AT OPENINGS BETWEEN ATTIC SPACES AND CHIMNEY SPACES FOR FACTORY-BUILT CHIMNEYS AND AT ANY OTHER LOCATION WHICH COULD AFFORD PASSAGE FOR FLAMES. (IRC R602.8) PROVIDE 30 LB. INTERLAYMENT BETWEEN COURSES OF SHAKES. SHOW ROOF VALLEY FLASHING TO BE MINIMUM 28 GAUGE GALVANIZED SHEET CORROSION-RESISTANT METAL, EXTENDING AT LEAST 11 INCHES FROM CENTER LINE OF VALLEY EACH WAY. PROVIDE ICE SHIELD THAT EXTENDS FROM THE EAVES TO A POINT 24 INCHES INSIDE THE EXTERIOR WALL LINE (IRC R905.8) ALL INTERIOR WALLS TO BE 2x4 DFL#2 STUDS @ 16" O.C. & EXTERIOR WALLS TO BE 2x6 DFL#2 STUDS @ 16" O.C. ALL LUMBER IN CONTACT W/ CONCRETE OR MASONRY SHALL BE PRESSURE-TREATED LUMBER. ALL HIP & VALLEY RAFTERS SHALL BE 2" THICK MIN, & NOT LESS IN DEPTH THAN THE CUT END OF THE RAFTER. (R802.3)

G23.

G24. G25. G26. G27. G28. G29.

SHEET TITLE

F5.

G30. G31.

F6.

F7. F8. F9. F10.

GENERAL PLUMBING NOTES


P1. P2. P3. P4. P5. P6. ALL PLUMBING SHALL COMPLY WITH CURRENT ADDITION OF THE INTERNATIONAL RESIDENTIAL CODE. PROVIDE LOCATION FOR GAS & ELECTRICAL METERS IN AN AREA THAT IS PROTECTED FROM SNOW AND ICE DAMAGE. PROVIDE WATER CLOSETS WITH A FLOW RATE OF NOT MORE THAN 1.6 GALLONS PER FLUSH (IRC R2903.2). PROVIDE SHOWER HEADS WITH A FLOW RATE OF NOT MORE THAN 2.5 GALLONS PER MINUTE (IRC P2903.2). PROVIDE AN EXPANSION TANK ON THE CULINARY WATER SYSTEM. WATER HEATERS AND EXPANSION TANKS TO BE ANCHORED OR STRAPPED IN THE UPPER THIRD OF THE APPLIANCE TO RESIST A HORIZONTAL FORCE EQUAL TO ONE THIRD OF THE OPERATING WEIGHT. (IRC P2801.2) HOSE BIBS TO BE NON-FREEZE TYPE BACK-FLOW PREVENT (IRC P2902.3.3, P2603.6). ALL PLUMBING VENTS THROUGH ROOF TO BE 3" PIPE MINIMUM. (IRC P3103.2). PROVIDE LOCATION OF ACCESS FOR WHIRLPOOL TYPE TUBS. NO GROUTED TILE ACCESS. (IRC P2720, E4109.3) SHOWERS SHALL BE FINISHED TO A HEIGHT OF NOT LESS THAN 72" ABOVE THE FLOOR. MATERIAL SHALL BE NON-ABSORBENT. (IRC R307.2) PROVIDE A FLOOR DRAIN BY THE WATER HEATER. SHOW A METAL PAN UNDER THE WATER HEATER OR STEAM SHOWER EQUIPMENT IF LOCATED ON A WOOD FLOOR. (IRC 2801) MINIMUM FINISHED SPACE WIDTH FOR WATER CLOSET TO BE 30" W/ A MINIMUM CLEARANCE OF 21" IN FRONT OF THE WATER CLOSET. PROVIDE A SHUTOFF VALVE FOR ALL PLUMBING FIXTURE SUPPLIES. GREEN BOARD CAN NOT BE USED BEHIND THE TILE IN THE SHOWER AND TUB ENCLOSURES.

F11. F12. F13.

F14.

385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555
COPYRIGHT 2010. ALL RIGHTS RESERVED BY LOG CRAFT, INC. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

P7. P8. P9. P10. P11. P12. P13. P14.

F15. F16.

F17.

F18. F19. F20.

SHEET NUMBER

A2.0

NT

NT

03/03/11

DATE:

LOT 53, Dutch Fields Midway, UT 84049

NOTE: THESE PLANS ARE A REFERENCE ONLY. CONTRACTOR TO VERIFY THAT ITS CONTENTS ARE CORRECT & MEET CURRENT BUILDING CODES PRIOR TO CONSTRUCTION.

REVISIONS

89' - 0" 2' - 0" 29' - 0" 5' - 6" 22' - 6" 6' - 0" 3' - 6" 18' - 6" 18' - 0" 3' - 6" 5' - 6" 20' - 0" 13' - 0" 10' - 0" 3' - 0" 2' - 0" 7' - 0"
DATE

5' - 6"

5' - 6"

10 A6.1 301 302 303

20 A6.1

Cold Storage
19'-4" x 11'-4"

7' - 0"

15' -11" x 12'-0" 6' - 0"

POCKET w/ SIDE LITES DOUBLE SLIDING GLASS TEMPERED

TEMPERED

C-5 5' - 4" 6' - 0" WOOD-BURNING OPEN BOX w/ PRE-MANUF. GAS LOG INSERT

14' - 2"

14' - 0"

Unexcavated Kitchenette

Storage

10' - 11"

Family / Rec. Room


35'-6" x 19'-4" 12' - 6"

LOWER LEVEL PLAN


SHEET TITLE

CHECKED BY: DRAWN BY:

26' - 0"

65' - 6"

FURN
5' - 1" 4' - 5" 2' - 4" 19' - 7" 16' - 0" C-7 PIANO C-2 C-4 C-6 2' - 2" 6' - 6" C-1 14' - 0" 2' - 0" DRAIN DIRECT VENT APPLIANCES 9' - 0"

Utility
W/H E/T

65' - 6"

1' - 2"

C-9

DOUBLE INSULATED DOUBLE INSULATED

W/H

E/T

C-8 8' - 6" 12' - 6"

Bath

Window Schedule Window Number


101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 201 202 203 204 205 206 207 208 209 210 211 212 213 214 301 302 303

Size
48" x 60" 48" x 60" 36" x 60" 36" x 60" 36" x 60" 36" x 48" 36" x 48" 30" x 60" 30" x 60" 30" x 60" 30" x 60" 30" x 60" 30" x 60" 24" x 48" 30" x 60" 30" x 60" 60" x 60" 72" x 60" 72" x 60" 48" x 60" 48" x 60" 60" x 60" 30" x 60" 30" x 60" 24" x 48" 60" x 60" 36" x 48" 60" x 60" 30" x 60" 30" x 60" 36" x 60" 36" x 60" 36" x 60"

Type
SLIDER SLIDER DOULBE HUNG DOULBE HUNG DOULBE HUNG SLIDER SLIDER DOULBE HUNG DOULBE HUNG DOULBE HUNG DOULBE HUNG DOULBE HUNG DOULBE HUNG DOULBE HUNG DOULBE HUNG DOULBE HUNG SLIDER SLIDER SLIDER SLIDER SLIDER SLIDER DOULBE HUNG DOULBE HUNG DOULBE HUNG SLIDER ARCH w/ SIDE LITES SLIDER DOULBE HUNG DOULBE HUNG DOULBE HUNG DOULBE HUNG DOULBE HUNG

Glazing

Exercise Room
19'-2" x 15'-1" 8' - 0"

Future Theatre
15'-11" x 15'-1" 14' - 2" 14' - 0"

5' - 1" 4' - 10"

1' - 4" C-3

Storage

3' - 0"

2' - 0"

2' - 0"

SCREEN

6' - 0"

TEMPERED

385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555
COPYRIGHT 2010. ALL RIGHTS RESERVED BY LOG CRAFT, INC. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

7' - 0"

2' - 0"

2' - 0"

2' - 0"

2' - 0"

7' - 0"

TEMPERED

6' - 0" 25' - 0" 13' - 0"

8' - 6"

7' - 6" 17' - 0" 89' - 0"

7' - 0"

12' - 0" 10' - 0"

7' - 0" 17' - 0"

7' - 6"

1' - 6" 2' - 0"

7' - 0"

NOTE: ALL DIMENSIONS ARE TO EDGE OF STUD OR CENTER OF STUD, NOT FINISHED MATERIAL. PLEASE NOTE AS TO WHICH SIDE OF THE STUD THE DIMENSION REFERS. (U.N.O.)

Lower Level
SCALE: 1/4" = 1'-0"

SHEET NUMBER

1528 Finished Sq. Ft.

A2.1

NT

NT

03/03/11

UP

DRAWINGS FOR:

Sitting

A-1 A-2 A-3 A-4 A-5 A-6 A-7 A-8 A-9 A-10 A-11 A-12 A-13 A-14 A-15 A-16 A-17 A-18 A-19 A-20 B-1 B-2 B-3 B-4 B-5 B-6 B-7 B-8 B-9 B-10 B-11 B-12 B-13 B-14 B-15 B-16 C-1 C-2 C-3 C-4 C-5 C-6 C-7 C-8 C-9

18' x 8' 10' x 9' 36" x 96" 36" x 96" 36" x 96" 36" x 96" 30" x 96" 36" x 96" 30" x 96" 72" x 96" 12' x 8' 60" x 96" 36" x 96" 30" x 96" 28" x 96" 36" x 96" 42" x 96" 60" x 96" 36" x 96" 60" x 96" 24" x 96" 30" x 96" 36" x 96" 36" x 96" 30" x 96" 36" x 96" 30" x 96" 30" x 96" 36" x 96" 30" x 96" 30" x 96" 28" x 96" 30" x 96" 36" x 96" 30" x 96" 30" x 96" 30" x 84" 30" x 84" 30" x 84" 60" x 84" 36" x 84" 60" x 84" 36" x 84" 36" x 84" 36" x 84"

12' - 0"

12' - 0"

12' - 0"

SLIDING GLASS SLIDING GLASS DOUBLE GLASS

TEMPERED TEMPERED TEMPERED

DATE:

LOT 53, Dutch Fields Midway, UT 84049

GARAGE GARAGE EXTERIOR FIRE RATED EXTERIOR

Nichols, Steve and Kris

Door Number

Size

Door Schedule Comments

Glazing

5' - 0"

NOTE: THESE PLANS ARE A REFERENCE ONLY. CONTRACTOR TO VERIFY THAT ITS CONTENTS ARE CORRECT & MEET CURRENT BUILDING CODES PRIOR TO CONSTRUCTION.

REVISIONS

2' - 0" 14' - 9"

29' - 0" 10' - 9" 3' - 6" 5' - 6" 3' - 6"

18' - 0" 3' - 6" 5' - 6" 10' - 0"

21' - 2" 16' - 10" 10' - 0" 9' - 6"

11' - 10" 6' - 2" 3' - 6"

7' - 0"
REVISIONS

7' - 0"

5' - 6"

102 1' - 0" A-3

103

104

105

5' - 6"

12' - 0"

10' - 0"

A-2

1-Car Garage
28'-5" x 11'-6" 6' - 0"

Dining
17'-0" x 17'-6" 7' - 0" 5' - 9" 20 A6.1

12' - 0"

A-10

10 A6.1 1' - 0"

4' - 0"

A-11 UP 5' - 1" 2' - 6" BUILT-INS

A-12 116 6' - 0"

9' - 5"

11'-4" x 13'-7" D/W 20'-4" x 20'-0" 5' - 0"

Great Room
GAS COOKTOP 26' - 0" 18' - 0"

A-1

24'-5" x 25'-6" VENT HOOD BLOWER TO OUTSIDE

65' - 6"

4' - 2"

D/W

2' - 0"

2-Car Garage

17'-2" x 16'-6" 4' - 8"

115 5' - 10"

1' - 8"

3' - 10"

MICRO 3' - 5" 4' - 6" A-13 DOWN 4' - 6" 9' - 0" 7' - 1" 1' - 9" 4' - 4" REF. A-16 DRAIN 2' - 3" 7' - 8" 3' - 11" 4' - 1" 11' - 0" 2' - 1" 1' - 1" 4' - 8" A-15 4' - 8" A-14 LINEN

MAIN LEVEL PLAN


SHEET TITLE

12' - 6"

Kitchen

WOOD-BURNING OPEN BOX w/ PRE-MANUF. GAS LOG INSERT

65' - 6"

CHECKED BY: DRAWN BY:

ATTIC ACCESS

Bath

114

WASH

4' - 0"

2' - 3"

12' - 6"

DRY

BUILT-INS A-8

5' - 6"

3' - 10"

A-6

3' - 4"

3' - 0"

101 A-5

Mud

6' - 10"

Window Schedule Window Number


101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 201 202 203 204 205 206 207 208 209 210 211 212 213 214 301 302 303 14' - 0"

Size
48" x 60" 48" x 60" 36" x 60" 36" x 60" 36" x 60" 36" x 48" 36" x 48" 30" x 60" 30" x 60" 30" x 60" 30" x 60" 30" x 60" 30" x 60" 24" x 48" 30" x 60" 30" x 60" 60" x 60" 72" x 60" 72" x 60" 48" x 60" 48" x 60" 60" x 60" 30" x 60" 30" x 60" 24" x 48" 60" x 60" 36" x 48" 60" x 60" 30" x 60" 30" x 60" 36" x 60" 36" x 60" 36" x 60"

Type
SLIDER SLIDER DOULBE HUNG DOULBE HUNG DOULBE HUNG SLIDER SLIDER DOULBE HUNG DOULBE HUNG DOULBE HUNG DOULBE HUNG DOULBE HUNG DOULBE HUNG DOULBE HUNG DOULBE HUNG DOULBE HUNG SLIDER SLIDER SLIDER SLIDER SLIDER SLIDER DOULBE HUNG DOULBE HUNG DOULBE HUNG SLIDER ARCH w/ SIDE LITES SLIDER DOULBE HUNG DOULBE HUNG DOULBE HUNG DOULBE HUNG DOULBE HUNG

Glazing

8' - 0"

DOWN A-7 5' - 0" 8' - 6"

Sewing Room 1/2


11'-2" x 11'-3"

6' - 4"

Entry

A-18

Office
14'-4" x 13'-7"

A-20

3' - 0"

106 GAS METER

UP 107

2' - 0"

4' - 2"

BUILT-INS

6' - 0"

7' - 2"

BENCH/COATS

108

109

110

A-17

111

112

113

5' - 0"

DRYER VENT

7' - 0"

2' - 0"

TEMPERED

385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555
COPYRIGHT 2010. ALL RIGHTS RESERVED BY LOG CRAFT, INC. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

2' - 0"

2' - 0"

DOWN

2' - 0"

2' - 0"

TEMPERED

18' - 0" 12' - 9" 12' - 3"

7' - 0" 2' - 10"

6' - 0" 6' - 4" 7' - 1"

7' - 0" 3' - 10" 5' - 11" 13' - 0"

1' - 6" 2' - 6"

7' - 6" 3' - 0" 3' - 0" 11' - 9" 17' - 0" 89' - 0"

7' - 0" 8' - 6" 5' - 3" 5' - 0"

12' - 0" 5' - 0"

7' - 0" 8' - 6" 3' - 0"

7' - 6" 3' - 0"

1' - 6" 2' - 6"

7' - 0"

25' - 0"

10' - 0"

17' - 0"

2' - 0" NOTE: ALL DIMENSIONS ARE TO EDGE OF STUD OR CENTER OF STUD, NOT FINISHED MATERIAL. PLEASE NOTE AS TO WHICH SIDE OF THE STUD THE DIMENSION REFERS. (U.N.O.)

Main Level
SCALE: 1/4" = 1'-0"

SHEET NUMBER

2324 Sq. Ft.

A2.2

NT

ELECTRIC METER

UP

A-4

Lndry

5' - 10"

A-9

PANTRY

A-19

4' - 6"

DOUBLE INSULATED DOUBLE INSULATED

NT

03/03/11

Guest Suite

A-1 A-2 A-3 A-4 A-5 A-6 A-7 A-8 A-9 A-10 A-11 A-12 A-13 A-14 A-15 A-16 A-17 A-18 A-19 A-20 B-1 B-2 B-3 B-4 B-5 B-6 B-7 B-8 B-9 B-10 B-11 B-12 B-13 B-14 B-15 B-16 C-1 C-2 C-3 C-4 C-5 C-6 C-7 C-8 C-9

18' x 8' 10' x 9' 36" x 96" 36" x 96" 36" x 96" 36" x 96" 30" x 96" 36" x 96" 30" x 96" 72" x 96" 12' x 8' 60" x 96" 36" x 96" 30" x 96" 28" x 96" 36" x 96" 42" x 96" 60" x 96" 36" x 96" 60" x 96" 24" x 96" 30" x 96" 36" x 96" 36" x 96" 30" x 96" 36" x 96" 30" x 96" 30" x 96" 36" x 96" 30" x 96" 30" x 96" 28" x 96" 30" x 96" 36" x 96" 30" x 96" 30" x 96" 30" x 84" 30" x 84" 30" x 84" 60" x 84" 36" x 84" 60" x 84" 36" x 84" 36" x 84" 36" x 84"

SLIDING GLASS SLIDING GLASS DOUBLE GLASS

TEMPERED TEMPERED TEMPERED

2' - 7"

POCKET w/ SIDE LITES DOUBLE SLIDING GLASS TEMPERED

7' - 0"

TEMPERED

OVENS

14' - 0"

DRAWINGS FOR:

DATE:

LOT 53, Dutch Fields Midway, UT 84049

GARAGE GARAGE EXTERIOR FIRE RATED EXTERIOR

Nichols, Steve and Kris

DOWN 5' - 0" 6' - 3"

Door Number

Size

Door Schedule Comments

Glazing

DATE

NOTE: THESE PLANS ARE A REFERENCE ONLY. CONTRACTOR TO VERIFY THAT ITS CONTENTS ARE CORRECT & MEET CURRENT BUILDING CODES PRIOR TO CONSTRUCTION.

89' - 0"

HOSE BIBS

59' - 0" 5' - 1" 5' - 5" 14' - 0" 7' - 0" 7' - 3" 14' - 0" 18' - 3" 12' - 0" 2' - 8" 10' - 10" 11' - 4" 6' - 2"
DATE

2' - 0"

10 A6.1

20 A6.1

Door Number
A-1 A-2 A-3 A-4 A-5 A-6 A-7 A-8 A-9 A-10 A-11 A-12 A-13 A-14 A-15 A-16 A-17 A-18 A-19 A-20 B-1 B-2 B-3 B-4 B-5 B-6 B-7 B-8 B-9 B-10 B-11 B-12 B-13 B-14 B-15 B-16 C-1 C-2 C-3 C-4 C-5 C-6 C-7 C-8 C-9 39' - 0"

Size
18' x 8' 10' x 9' 36" x 96" 36" x 96" 36" x 96" 36" x 96" 30" x 96" 36" x 96" 30" x 96" 72" x 96" 12' x 8' 60" x 96" 36" x 96" 30" x 96" 28" x 96" 36" x 96" 42" x 96" 60" x 96" 36" x 96" 60" x 96" 24" x 96" 30" x 96" 36" x 96" 36" x 96" 30" x 96" 36" x 96" 30" x 96" 30" x 96" 36" x 96" 30" x 96" 30" x 96" 28" x 96" 30" x 96" 36" x 96" 30" x 96" 30" x 96" 30" x 84" 30" x 84" 30" x 84" 60" x 84" 36" x 84" 60" x 84" 36" x 84" 36" x 84" 36" x 84"

Door Schedule Comments


GARAGE GARAGE EXTERIOR FIRE RATED EXTERIOR

Glazing

Nichols, Steve and Kris UPPER LEVEL

SLIDING GLASS SLIDING GLASS DOUBLE GLASS

TEMPERED TEMPERED TEMPERED

POCKET w/ SIDE LITES DOUBLE SLIDING GLASS TEMPERED


DRAWINGS FOR:

TUB ACCESS

203

204

205

206

TEMPERED

5' - 2"

5' - 11"

4' - 10"

B-16

207

4' - 8"

4' - 5"

B-2 B-3

B-15

Master Suite
17'-10" x 15'-5" 5' - 0"

10'-10" x 13'-7"

1' - 9"

11' - 3"

ATTIC ACCESS

3' - 10"

6' - 0"

PRE-MANUF. GAS INSERT 2x6 SOUND PROOF WALL 5' - 0" 4' - 7" 5' - 7" 3' - 10"

1' - 2"

208 2' - 0"

CHECKED BY: DRAWN BY:

29' - 0"

2' - 3"

34' - 0"

5' - 1"

6' - 11" 4' - 3" 2' - 0"

8' - 8" 5' - 6"

4' - 1"

4' - 3"

39' - 0"

DRYER VENT

Balcony
B-6 DOWN B-8 LINEN

B-13

B-12

209

4' - 6"

2' - 2"

2' - 10"

9' - 0"

ATTIC ACCESS

Bath

6' - 2"

DOWN

B-5

4' - 6"

WASHER DRYER COMBO

Bath

B-4

B-14

DOUBLE INSULATED DOUBLE INSULATED

SHEET TITLE

4' - 0"

B-10 B-9 B-7

B-11 2' - 0"

Window Schedule Window Number


101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 201 202 203 204 205 206 207 208 209 210 211 212 213 214 301 302 303

214 3' - 2" 4' - 7" 4' - 6" 4' - 11"

Size
48" x 60" 48" x 60" 36" x 60" 36" x 60" 36" x 60" 36" x 48" 36" x 48" 30" x 60" 30" x 60" 30" x 60" 30" x 60" 30" x 60" 30" x 60" 24" x 48" 30" x 60" 30" x 60" 60" x 60" 72" x 60" 72" x 60" 48" x 60" 48" x 60" 60" x 60" 30" x 60" 30" x 60" 24" x 48" 60" x 60" 36" x 48" 60" x 60" 30" x 60" 30" x 60" 36" x 60" 36" x 60" 36" x 60"

Type
SLIDER SLIDER DOULBE HUNG DOULBE HUNG DOULBE HUNG SLIDER SLIDER DOULBE HUNG DOULBE HUNG DOULBE HUNG DOULBE HUNG DOULBE HUNG DOULBE HUNG DOULBE HUNG DOULBE HUNG DOULBE HUNG SLIDER SLIDER SLIDER SLIDER SLIDER SLIDER DOULBE HUNG DOULBE HUNG DOULBE HUNG SLIDER ARCH w/ SIDE LITES SLIDER DOULBE HUNG DOULBE HUNG DOULBE HUNG DOULBE HUNG DOULBE HUNG

Glazing

Loft
12'-7" x 17'-0" OPEN TO BELOW 201 9' - 4"

9' - 5"

5' - 0"

Bedroom #4
11'-2" x 11'-9"

Bedroom #3
16'-7" x 13'-7"

213 3' - 0" 2' - 7" 202

2' - 0"

1' - 6"

210 211 212

2' - 0"

14' - 0"

TEMPERED

385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555
COPYRIGHT 2010. ALL RIGHTS RESERVED BY LOG CRAFT, INC. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

TEMPERED

6' - 0" 13' - 0"

7' - 0"

8' - 6" 11' - 9"

8' - 6" 5' - 3" 59' - 0"

5' - 0" 10' - 0"

5' - 0" 5' - 0"

3' - 6" 7' - 0"

3' - 6" 5' - 0" 2' - 0" NOTE: ALL DIMENSIONS ARE TO EDGE OF STUD OR CENTER OF STUD, NOT FINISHED MATERIAL. PLEASE NOTE AS TO WHICH SIDE OF THE STUD THE DIMENSION REFERS. (U.N.O.)

Upper Level
SCALE: 1/4" = 1'-0"

1790 Sq. Ft.

SHEET NUMBER

A2.3

NT

NT

DRAIN

9' - 5"

ALLOW FOR CHIMNEY FLUE

Bedroom #2

14' - 0"

DATE:

M. Bath

3'

" 10

03/03/11

B-1

8' - 8"

2' - 10"

2' - 7"

LOT 53, Dutch Fields Midway, UT 84049

NOTE: THESE PLANS ARE A REFERENCE ONLY. CONTRACTOR TO VERIFY THAT ITS CONTENTS ARE CORRECT & MEET CURRENT BUILDING CODES PRIOR TO CONSTRUCTION.

REVISIONS

ARCH GRADE ASPHALT SHINGLES

8"

/1

2" 8"
7" /

12 "

CEDAR SHAKES

METAL ROOFING

" 3" / 12

" 3" / 12

Top Plate (Main) 10' - 0"


BOARD & BATTEN

DRAWINGS FOR:

Upper Level 11' - 0"

FRONT/REAR ELEVATIONS

STONE VENEER

Main Level 0' - 0" TOW -1' - 0"

TOF-Crawl -4' - 2" BOF-CRAWL -5' - 0" Lower Level -9' - 8" TOF -10' - 0" BOF -10' - 10"
SHEET TITLE

CHECKED BY: DRAWN BY:

SCALE: 1/4" = 1'-0"

ARCH GRADE ASPHALT SHINGLES

/ 7"

" 12

CEDAR SHAKES

BOARD & BATTEN

METAL ROOFING

/ 7"

" 12

385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555
COPYRIGHT 2010. ALL RIGHTS RESERVED BY LOG CRAFT, INC. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

STONE VENEER

SHEET NUMBER

REAR ELEVATION
SCALE: 1/4" = 1'-0"

A3.1

NT

FRONT ELEVATION

NT

03/03/11

DATE:

LOT 53, Dutch Fields Midway, UT 84049

Top Plate (Upper) 20' - 0"

Nichols, Steve and Kris

/1

2"

DATE

REVISIONS

Ridge Line 31' - 7 25/32"

NOTE: THESE PLANS ARE A REFERENCE ONLY. CONTRACTOR TO VERIFY THAT ITS CONTENTS ARE CORRECT & MEET CURRENT BUILDING CODES PRIOR TO CONSTRUCTION.

Ridge Line 31' - 7 25/32"

CRICKET
/ 7" " 12

ARCH GRADE ASPHALT SHINGLES


DATE

CEDAR SHAKES

Nichols, Steve and Kris SIDE ELEVATIONS

Top Plate (Upper) 20' - 0"


BOARD & BATTEN

METAL ROOFING

3" / 12 "

Upper Level 11' - 0" Top Plate (Main) 10' - 0"

DRAWINGS FOR:

STONE VENEER
DATE:

Main Level 0' - 0" TOW -1' - 0"

CHECKED BY: DRAWN BY:

RIGHT SIDE ELEVATION


SCALE: 1/4" = 1'-0"

SHEET TITLE

ARCH GRADE ASPHALT SHINGLES

/ 7"

" 12

CEDAR SHAKES

/ 7"

" 12

METAL ROOFING

385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555
COPYRIGHT 2010. ALL RIGHTS RESERVED BY LOG CRAFT, INC. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

BOARD & BATTEN

STONE VENEER

SHEET NUMBER

LEFT SIDE ELEVATION


SCALE: 1/4" = 1'-0"

A3.2

NT

NT

03/03/11

LOT 53, Dutch Fields Midway, UT 84049

NOTE: THESE PLANS ARE A REFERENCE ONLY. CONTRACTOR TO VERIFY THAT ITS CONTENTS ARE CORRECT & MEET CURRENT BUILDING CODES PRIOR TO CONSTRUCTION.

REVISIONS

2' - 0"

MIN.

DATE

Nichols, Steve and Kris 3D VIEWS - EXTERIOR

DRAWINGS FOR:

CHECKED BY: DRAWN BY:

3D - FRONT
SCALE:

SHEET TITLE

385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555
COPYRIGHT 2010. ALL RIGHTS RESERVED BY LOG CRAFT, INC. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

3D - GARAGE
SCALE:

3D - REAR
SCALE:

SHEET NUMBER

A4.1

NT

NT

03/03/11

DATE:

LOT 53, Dutch Fields Midway, UT 84049

NOTE: THESE PLANS ARE A REFERENCE ONLY. CONTRACTOR TO VERIFY THAT ITS CONTENTS ARE CORRECT & MEET CURRENT BUILDING CODES PRIOR TO CONSTRUCTION.

REVISIONS

DATE

Nichols, Steve and Kris AREA PLANS

Garage Area 998 SF Finished Area Finished Area 2324 SF


DRAWINGS FOR:

1790 SF

CHECKED BY: DRAWN BY:

Main Level
SCALE: 1/8" = 1'-0"

Upper Level
NOTE: AREA PLANS INDICATE GROSS SQUARE FOOTAGE.
SCALE: 1/8" = 1'-0"

NOTE: AREA PLANS INDICATE GROSS SQUARE FOOTAGE.

SHEET TITLE

Cold Storage Area 240 SF

Unexcavated Area 998 SF Finished Area 1528 SF Unfinished Area 512 SF


385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555
COPYRIGHT 2010. ALL RIGHTS RESERVED BY LOG CRAFT, INC. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

Future Area 284 SF

Lower Level
SCALE: 1/8" = 1'-0"

NOTE: AREA PLANS INDICATE GROSS SQUARE FOOTAGE.

SHEET NUMBER

A5.1

NT

NT

03/07/11

DATE:

LOT 53, Dutch Fields Midway, UT 84049

NOTE: THESE PLANS ARE A REFERENCE ONLY. CONTRACTOR TO VERIFY THAT ITS CONTENTS ARE CORRECT & MEET CURRENT BUILDING CODES PRIOR TO CONSTRUCTION.

REVISIONS

PRE-ENGINEERED TRUSSES
DATE

FLOOR JOISTS PER FRAMING PLAN LVL RIM BOARD NAIL OUTSIDE STRINGER TO STUD WALL

2x FRAME WALLS

Nichols, Steve and Kris BUILDING SECTIONS

MIN. R-38

SIMPSON LSU26

LVL STRINGERS

PRE-ENGINEERED JACK TRUSSES STAIR INFO: 17 RISERS @ 7 3/4" 16 TREADS @ 10" GRAB RAIL 36" ABOVE TREAD TOE 10" 7 3/4"

9' - 0"

MIN. R-19

RAFTER (PER PLAN)

6'-8" HEADROOM CLEARANCE

FLOOR JOISTS (PER PLAN)

LVL STRINGERS @ 12" O.C. GYP. BRD. PER ARCH. PLANS

8' - 0"

PORCH BEAM (PER PLAN)

HEADER (PER PLAN)

FLOOR BEAM (PER PLAN) 10' - 0"

STAIR SECTION 3/16" = 1'-0"

DRAWINGS FOR:

SIDE SECTION

FRONT SECTION

6'-8" HEADROOM CLEARANCE


DATE:

GRAB RAIL 36" ABOVE TREAD TOE

MIN. 36"

10" 7' - 6" 7 1/4" 4" CONCRETE SLAB

FLOOR JOISTS (PER PLAN) 8' - 8" HEADER (PER PLAN) STAIR INFO: 16 RISERS @ 7 1/4" 15 TREADS @ 10" FOUNDATION (PER PLAN)

CHECKED BY: DRAWN BY:

FURR WALL (TYPICAL FOUNDATION PERIMETER)

BUILDING SECTION #1
SCALE: 1/4" = 1'-0"

PRE-ENGINEERED TRUSSES 4" CONCRETE SLAB FOOTINGS (PER PLAN)

SHEET TITLE

MIN. R-38

2x6 SOUND PROOF WALL

PRE-ENGINEERED JACK TRUSSES


ROOF VENT

9' - 0"

MIN. R-19

Master Suite
17'-10" x 15'-5"

PRE-ENGINEERED JACK TRUSSES

FLOOR JOISTS (PER PLAN)


INSULATION BAFFLE

PROVIDE VENT HOLE IN EACH BLOCK

GRAB RAIL 36" ABOVE TREAD TOE PORCH BEAM (PER PLAN)

BLOCKING

7 3/4"

PORCH BEAM (PER PLAN) 10"

TRUSS

2" VENT STRIP

Great Room
20'-4" x 20'-0"
EXTERIOR WALL

8" CONCRETE SLAB

STAIR INFO: 17 RISERS @ 7 3/4" 16 TREADS @ 10"

DECK JOISTS (PER PLAN)

385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555
COPYRIGHT 2010. ALL RIGHTS RESERVED BY LOG CRAFT, INC. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

10' - 0"

DECK BEAM (PER PLAN)

ATTIC VENTING DETAIL 1/2" = 1'-0"


8' - 8"

FLOOR JOISTS (PER PLAN)

Cold Storage
19'-4" x 11'-4"

Family / Rec. Room


35'-6" x 19'-4"

Exercise Room
19'-2" x 15'-1" FURR WALL (TYPICAL FOUNDATION PERIMETER)

FOUNDATION (PER PLAN)

4" CONCRETE SLAB

FOOTINGS (PER PLAN)

SHEET NUMBER

BUILDING SECTION #2
SCALE: 1/4" = 1'-0"

A6.1

NT

NT

03/03/11

LOT 53, Dutch Fields Midway, UT 84049

NOTE: THESE PLANS ARE A REFERENCE ONLY. CONTRACTOR TO VERIFY THAT ITS CONTENTS ARE CORRECT & MEET CURRENT BUILDING CODES PRIOR TO CONSTRUCTION.

REVISIONS

E1. E2. E3. E4. E5. E6.

Nichols, Steve and Kris ELECTRICAL PLAN - LOWER

E7.

E8. E9. E10. E11. E12. E13. E14.

ELECTRICAL SYMBOL LEGEND

DRAWINGS FOR:

PLEASE CONTACT ELECTRICIAN & LOG STACKER PRIOR TO CONSTRUCTION OF BUILDING TO ENSURE ACCURACY OF ALL ELECTRICAL WIRING. ELECTRICAL WIRING ON THESE PRINTS ARE USED AS A GUIDE ONLY. CONSULT ELECTRICIAN FOR PROPER PLACEMENT OF ELECTRICAL FIXTURES. ALL RECEPTACLES SERVING KITCHEN COUNTERTOPS, IN GARAGES, BATHS, UNFINISHED BASEMENTS AND OUTSIDE RECEPTACLES SHALL BE GFCI PROTECTED (IRC E3802). EXTERIOR OUTLETS SHALL HAVE WATERPROOF COVERINGS. ALL ELECTRICAL OUTLET AND LIGHTING BRANCH CIRCUITS IN ALL BEDROOMS TO BE PROVIDED W/ ARC FAULT PROTECTION. PROVIDE SMOKE DETECTORS CONFORMING TO IRC SECTION R313. ALL LEVELS, ALL BEDROOMS, ACCESS TO ALL BEDROOMS, AND IN ALL ROOMS WITH SLOPED CEILINGS NEXT TO HALLS SERVING BEDROOMS. ALL SMOKE DETECTORS SHALL BE WIRED IN SERIES W/ BATTERY BACK UP. SMOKE DETECTORS SHALL BE INTERCONNECTED SUCH THAT ACTUATION OF ONE SHALL ACTUATE ALL SMOKE DETECTORS. (R313.1-2) CARBON MONOXIDE DETECTORS SHALL BE INSTALLED ON EACH HABITABLE LEVEL OF A DWELLING UNIT EQUIPPED WITH A FUEL BURNING APPLIANCE AND SHALL BE INTERCONNECTED W/ SMOKE DETECTORS & HARD WIRED W/ BATTERY BACK-UP. (R313.2 AS AMENDED BY STATE). ALL BATHROOM FANS TO BE VENTED TO EXTERIOR AT A RATE OF 50 CUBIC FEET PER MINUTE FOR INTERMITTENT OR 20 CUBIC FEET PER MINUTE FOR CONTINUOUS VENTILATION (IRC R303.3). COPPER GROUND ROD TO BE 1/2" x 8" DRIVEN VERTICALLY INTO GROUND BELOW METER BASE/DISCONNECT LOCATION FOR GROUNDING AND BONDING OF ALL METAL PIPING INCLUDING GAS ALL RECEPTACLES SERVICING UNFINISHED BASEMENTS TO BE GFCI PROTECTED. ELECTRICAL PANELS MUST HAVE 30" WIDE BY 36" DEEP WORKING SPACE & 6'-6" HEADROOM. PROVIDE PROPER FIRE RATING FOR BOXES FACING INTO GARAGES. ALL SPAS AND HOT TUBS SHALL COMPLY WITH THE CURRENT INTERNATIONAL RESIDENTIAL CODE, SPECIFICALLY EQUIPMENT LOCATION AND CLEARANCES SHALL COMPLY WITH E4103. PROVIDE A COMFORT HEATING SYSTEM CAPABLE OF MAINTAINING 68 DEGREES F AT A POINT 36 INCHES ABOVE THE FLOOR IN ALL ROOMS (IRC R303.8). OUTLETS ARE REQUIRED TO BE INSTALLED SO THAT NO POINT ALONG WALLS IS MORE THAN 6 FEET FROM AN OUTLET.

DATE

S/C

SWITCH DIMMER SWITCH FAN SWITCH JAMB-MOUNTED AUTOMATIC SWITCH DUPLEX OUTLET w/ ARCH FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET

CEILING FAN w/ FAN LIGHT

D F

PENDANT LIGHT FIXTURE

REF.

WALL SCONCE

CHECKED BY: DRAWN BY:

BLOWER

AFI

SURFACE MOUNTED LIGHT FIXTURE

DIRECTIONAL LIGHT FIXTURE DUPLEX OUTLET - HALF SWITCHED


GFI GFI

220

GFI FURN

DUPLEX OUTLET w/ GROUND FAULT CIRCUIT INTERRUPTER

DOWNLIGHT (CAN)

SHEET TITLE

CONTINUOUS UNDERCABINET LIGHT


U

DEDICATED OUTLET OR JUNCTION BOX TO COORDINATE w/ EQUIP. 30" 36" 36" CLEARANCE FLOOR RECEPTACLE
GFI

CLOSET UTILITY LIGHT

GFI

ELECT. PANEL

W/H

E/T

W/H

E/T
FLOOR RECEPTACLE - HALF SWITCHED

SD

SMOKE DETECTOR

ELECTRIC METER (MAIN LEVEL)

S/C
GFI

SMOKE / CARBON MONOXIDE DETECTOR EXHAUST FAN VENT

WP/GFI

EXTERIOR RECEPTACLE w/ WATERPROOF COVER & GROUND FAULT INTERRUPTER

FLUORESCENT LIGHT FIXTURE


GFI

TV / DATA

DC

DOOR CHIME

TELEPHONE JACK

THERMOSTAT

UFER GROUND GAS METER (MAIN LEVEL)

385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555
COPYRIGHT 2010. ALL RIGHTS RESERVED BY LOG CRAFT, INC. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

ELECTRICAL PLAN - Lower Level


SCALE: 1/4" = 1'-0"

SHEET NUMBER

E1.1

NT

FURN

WATERPROOF SHOWER LIGHT DUPLEX OUTLET w/ GROUND GFI 42" FAULT CIRCUIT INTERRUPTER LOCATED 42" MIN. A.F.F.

NT

GFI

03/07/11

DATE:

LOT 53, Dutch Fields Midway, UT 84049

NOTE: THESE PLANS ARE A REFERENCE ONLY. CONTRACTOR TO VERIFY THAT ITS CONTENTS ARE CORRECT & MEET CURRENT BUILDING CODES PRIOR TO CONSTRUCTION.

ELECTRICAL NOTES
REVISIONS

F GFI

E1. E2. E3. E4. E5. E6.

Nichols, Steve and Kris ELECTRICAL PLAN - MAIN

E7.

E8. E9. E10. E11.


GFI GFI WP/GFI

E12. E13.

E14.

ELECTRICAL SYMBOL LEGEND

DRAWINGS FOR:

GFI-CEILING

PLEASE CONTACT ELECTRICIAN & LOG STACKER PRIOR TO CONSTRUCTION OF BUILDING TO ENSURE ACCURACY OF ALL ELECTRICAL WIRING. ELECTRICAL WIRING ON THESE PRINTS ARE USED AS A GUIDE ONLY. CONSULT ELECTRICIAN FOR PROPER PLACEMENT OF ELECTRICAL FIXTURES. ALL RECEPTACLES SERVING KITCHEN COUNTERTOPS, IN GARAGES, BATHS, UNFINISHED BASEMENTS AND OUTSIDE RECEPTACLES SHALL BE GFCI PROTECTED (IRC E3802). EXTERIOR OUTLETS SHALL HAVE WATERPROOF COVERINGS. ALL ELECTRICAL OUTLET AND LIGHTING BRANCH CIRCUITS IN ALL BEDROOMS TO BE PROVIDED W/ ARC FAULT PROTECTION. PROVIDE SMOKE DETECTORS CONFORMING TO IRC SECTION R313. ALL LEVELS, ALL BEDROOMS, ACCESS TO ALL BEDROOMS, AND IN ALL ROOMS WITH SLOPED CEILINGS NEXT TO HALLS SERVING BEDROOMS. ALL SMOKE DETECTORS SHALL BE WIRED IN SERIES W/ BATTERY BACK UP. SMOKE DETECTORS SHALL BE INTERCONNECTED SUCH THAT ACTUATION OF ONE SHALL ACTUATE ALL SMOKE DETECTORS. (R313.1-2) CARBON MONOXIDE DETECTORS SHALL BE INSTALLED ON EACH HABITABLE LEVEL OF A DWELLING UNIT EQUIPPED WITH A FUEL BURNING APPLIANCE AND SHALL BE INTERCONNECTED W/ SMOKE DETECTORS & HARD WIRED W/ BATTERY BACK-UP. (R313.2 AS AMENDED BY STATE). ALL BATHROOM FANS TO BE VENTED TO EXTERIOR AT A RATE OF 50 CUBIC FEET PER MINUTE FOR INTERMITTENT OR 20 CUBIC FEET PER MINUTE FOR CONTINUOUS VENTILATION (IRC R303.3). COPPER GROUND ROD TO BE 1/2" x 8" DRIVEN VERTICALLY INTO GROUND BELOW METER BASE/DISCONNECT LOCATION FOR GROUNDING AND BONDING OF ALL METAL PIPING INCLUDING GAS ALL RECEPTACLES SERVICING UNFINISHED BASEMENTS TO BE GFCI PROTECTED. ELECTRICAL PANELS MUST HAVE 30" WIDE BY 36" DEEP WORKING SPACE & 6'-6" HEADROOM. PROVIDE PROPER FIRE RATING FOR BOXES FACING INTO GARAGES. ALL SPAS AND HOT TUBS SHALL COMPLY WITH THE CURRENT INTERNATIONAL RESIDENTIAL CODE, SPECIFICALLY EQUIPMENT LOCATION AND CLEARANCES SHALL COMPLY WITH E4103. PROVIDE A COMFORT HEATING SYSTEM CAPABLE OF MAINTAINING 68 DEGREES F AT A POINT 36 INCHES ABOVE THE FLOOR IN ALL ROOMS (IRC R303.8). OUTLETS ARE REQUIRED TO BE INSTALLED SO THAT NO POINT ALONG WALLS IS MORE THAN 6 FEET FROM AN OUTLET.

DATE

F GFI AFI AFI

SWITCH DIMMER SWITCH FAN SWITCH JAMB-MOUNTED AUTOMATIC SWITCH DUPLEX OUTLET w/ ARCH FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET

CEILING FAN w/ FAN LIGHT

OVENS

F J

PENDANT / CHANDELIER LIGHT FIXTURE

WALL SCONCE

CHECKED BY: DRAWN BY:

GFI

D/W

BLOWER AFI AFI

SURFACE MOUNTED LIGHT FIXTURE

GFI-CEILING

HOOD

DIRECTIONAL LIGHT FIXTURE D/W SD


A FI

DUPLEX OUTLET - HALF SWITCHED DUPLEX OUTLET w/ GROUND FAULT CIRCUIT INTERRUPTER DOWNLIGHT (CAN)

GFI

MICRO

GFI

GFI

GFI

WATERPROOF SHOWER LIGHT


SHEET TITLE

GFI

CONTINUOUS UNDERCABINET LIGHT


U

S/C
F

WP/GFI

DEDICATED OUTLET OR JUNCTION BOX TO COORDINATE w/ EQUIP. FLOOR RECEPTACLE SD CLOSET UTILITY LIGHT

WASH

DC

ELECTRIC METER

DRY

WP/GFI

GFI

GAS METER

WP/GFI

ELECTRICAL PLAN - Main Level


SCALE: 1/4" = 1'-0"

GFI

REF.

SMOKE DETECTOR

W
F

FLOOR RECEPTACLE - HALF SWITCHED S/C EXTERIOR RECEPTACLE w/ WATERPROOF COVER & GROUND FAULT INTERRUPTER SMOKE / CARBON MONOXIDE DETECTOR EXHAUST FAN VENT

WP/GFI

FLUORESCENT LIGHT FIXTURE

TV / DATA

DC

DOOR CHIME

TELEPHONE JACK

THERMOSTAT

385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555
WP/GFI
COPYRIGHT 2010. ALL RIGHTS RESERVED BY LOG CRAFT, INC. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

SHEET NUMBER

E1.2

NT

DUPLEX OUTLET w/ GROUND GFI 42" FAULT CIRCUIT INTERRUPTER LOCATED 42" MIN. A.F.F.

NT

03/07/11

DATE:

LOT 53, Dutch Fields Midway, UT 84049

NOTE: THESE PLANS ARE A REFERENCE ONLY. CONTRACTOR TO VERIFY THAT ITS CONTENTS ARE CORRECT & MEET CURRENT BUILDING CODES PRIOR TO CONSTRUCTION.

ELECTRICAL NOTES
REVISIONS

WP/GFI

GFI

GFI

WP/GFI

GFI AFI

GFI GFI

D P. IS
AFI

GFI

GFI

GFI 220

GFI

GFI

E1. E2. E3. E4. E5. E6.

Nichols, Steve and Kris ELECTRICAL PLAN - UPPER

E7.

E8. E9. E10. E11. E12. E13. E14.

ELECTRICAL SYMBOL LEGEND


TUB ACCESS

DRAWINGS FOR:

PLEASE CONTACT ELECTRICIAN & LOG STACKER PRIOR TO CONSTRUCTION OF BUILDING TO ENSURE ACCURACY OF ALL ELECTRICAL WIRING. ELECTRICAL WIRING ON THESE PRINTS ARE USED AS A GUIDE ONLY. CONSULT ELECTRICIAN FOR PROPER PLACEMENT OF ELECTRICAL FIXTURES. ALL RECEPTACLES SERVING KITCHEN COUNTERTOPS, IN GARAGES, BATHS, UNFINISHED BASEMENTS AND OUTSIDE RECEPTACLES SHALL BE GFCI PROTECTED (IRC E3802). EXTERIOR OUTLETS SHALL HAVE WATERPROOF COVERINGS. ALL ELECTRICAL OUTLET AND LIGHTING BRANCH CIRCUITS IN ALL BEDROOMS TO BE PROVIDED W/ ARC FAULT PROTECTION. PROVIDE SMOKE DETECTORS CONFORMING TO IRC SECTION R313. ALL LEVELS, ALL BEDROOMS, ACCESS TO ALL BEDROOMS, AND IN ALL ROOMS WITH SLOPED CEILINGS NEXT TO HALLS SERVING BEDROOMS. ALL SMOKE DETECTORS SHALL BE WIRED IN SERIES W/ BATTERY BACK UP. SMOKE DETECTORS SHALL BE INTERCONNECTED SUCH THAT ACTUATION OF ONE SHALL ACTUATE ALL SMOKE DETECTORS. (R313.1-2) CARBON MONOXIDE DETECTORS SHALL BE INSTALLED ON EACH HABITABLE LEVEL OF A DWELLING UNIT EQUIPPED WITH A FUEL BURNING APPLIANCE AND SHALL BE INTERCONNECTED W/ SMOKE DETECTORS & HARD WIRED W/ BATTERY BACK-UP. (R313.2 AS AMENDED BY STATE). ALL BATHROOM FANS TO BE VENTED TO EXTERIOR AT A RATE OF 50 CUBIC FEET PER MINUTE FOR INTERMITTENT OR 20 CUBIC FEET PER MINUTE FOR CONTINUOUS VENTILATION (IRC R303.3). COPPER GROUND ROD TO BE 1/2" x 8" DRIVEN VERTICALLY INTO GROUND BELOW METER BASE/DISCONNECT LOCATION FOR GROUNDING AND BONDING OF ALL METAL PIPING INCLUDING GAS ALL RECEPTACLES SERVICING UNFINISHED BASEMENTS TO BE GFCI PROTECTED. ELECTRICAL PANELS MUST HAVE 30" WIDE BY 36" DEEP WORKING SPACE & 6'-6" HEADROOM. PROVIDE PROPER FIRE RATING FOR BOXES FACING INTO GARAGES. ALL SPAS AND HOT TUBS SHALL COMPLY WITH THE CURRENT INTERNATIONAL RESIDENTIAL CODE, SPECIFICALLY EQUIPMENT LOCATION AND CLEARANCES SHALL COMPLY WITH E4103. PROVIDE A COMFORT HEATING SYSTEM CAPABLE OF MAINTAINING 68 DEGREES F AT A POINT 36 INCHES ABOVE THE FLOOR IN ALL ROOMS (IRC R303.8). OUTLETS ARE REQUIRED TO BE INSTALLED SO THAT NO POINT ALONG WALLS IS MORE THAN 6 FEET FROM AN OUTLET.

DATE

SWITCH
AFI

CEILING FAN w/ FAN LIGHT

W
F

D AFI F

DIMMER SWITCH FAN SWITCH JAMB-MOUNTED AUTOMATIC SWITCH DUPLEX OUTLET w/ ARCH FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET DIRECTIONAL LIGHT FIXTURE DUPLEX OUTLET - HALF SWITCHED DOWNLIGHT (CAN) DUPLEX OUTLET w/ GROUND FAULT CIRCUIT INTERRUPTER WATERPROOF SHOWER LIGHT
W

PENDANT LIGHT FIXTURE

WALL SCONCE

A FI

CHECKED BY: DRAWN BY:

DATE:

AFI

AFI

AFI

AFI

AFI

SURFACE MOUNTED LIGHT FIXTURE

AFI

SHEET TITLE

CONTINUOUS UNDERCABINET LIGHT


U

DEDICATED OUTLET OR JUNCTION BOX TO COORDINATE w/ EQUIP. CLOSET UTILITY LIGHT FLOOR RECEPTACLE SD SMOKE DETECTOR

FLOOR RECEPTACLE - HALF SWITCHED


AFI F AFI

S/C EXTERIOR RECEPTACLE w/ WATERPROOF COVER & GROUND FAULT INTERRUPTER

SMOKE / CARBON MONOXIDE DETECTOR EXHAUST FAN VENT

AFI

AFI

WP/GFI

FLUORESCENT LIGHT FIXTURE

TV / DATA

DC

DOOR CHIME

TELEPHONE JACK
AFI

THERMOSTAT

AFI

385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555
COPYRIGHT 2010. ALL RIGHTS RESERVED BY LOG CRAFT, INC. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

ELECTRICAL PLAN - Upper Level


SCALE: 1/4" = 1'-0"

SHEET NUMBER

E1.3

NT

AFI

AFI

AFI

AFI

AFI

WASHER DRYER COMBO

GFI GFI

DUPLEX OUTLET w/ GROUND GFI 42" FAULT CIRCUIT INTERRUPTER LOCATED 42" MIN. A.F.F.

NT

03/07/11

GFI-TUB

LOT 53, Dutch Fields Midway, UT 84049

NOTE: THESE PLANS ARE A REFERENCE ONLY. CONTRACTOR TO VERIFY THAT ITS CONTENTS ARE CORRECT & MEET CURRENT BUILDING CODES PRIOR TO CONSTRUCTION.

ELECTRICAL NOTES
REVISIONS

AFI

AFI

AFI

GFI

AFI AFI BLOWER GFI AFI AFI AFI AFI

NO

DATE

ISSUE

GENERAL STRUCTURAL NOTES:


DESIGN CODE: 2006 INTERNATIONAL RESIDENTIAL CODE DESIGN LOADS: LIVE LOADS USED IN DESIGN: 1. ROOF A) FLAT ROOF SNOW LOAD, Pf B) DEAD LOAD B) SNOW EXPOSURE COEFFICIENT, Ce C) GROUND SNOW LOAD, Pg D) IMPORTANCE FACTOR, I 2. FLOOR A) LIVE LOAD B) DEAD LOAD 3. WIND PRESSURE A) BASIC WIND SPEED B) BUILDING CATEGORY C) IMPORTANCE FACTOR, Iw D) EXPOSURE CLASSIFICATION 4. SEISMIC LOADS A) SEISMIC DESIGN CATEGORY B) SITE CLASS C) IMPORTANCE FACTOR, Ie D) MAPPED SPECTRAL RESPONSE ACCELERATION Ss E) SPECTRAL RESPONSE COEFFICIENT Sds

SHEATHING NOTES:
FLOOR SHEATHING: 3/4" (48/24) APA RATED T&G SUBFLOOR 10d COMMON @ 6" O.C. AT PANEL EDGES, 10d COMMON @ 10" O.C. FIELD. ATTACH PANEL TO FRAMEWORK w/ A CONTINUOUS BEAD OF CONSTRUCTION ADHESIVE OR AS REQ'D BY FINISH FLOOR MATERIAL. ROOF SHEATHING: 5/8" (40/20) APA RATED SHEATHING 8d COMMON @ 6" O.C. AT PANEL EDGES, 8d COMMON @ 12" O.C. FIELD. EXTERIOR WALL SHEATHING: 7/16" STRUCTURAL "I" RATED PANELS 8d COMMON @ 4" O.C. AT PANEL EDGES, 8d COMMON @ 12" O.C. FIELD. BLOCK ALL SHEATHING EDGES w/ 2" NOMINAL BLOCKING. (TYPICAL UNLESS NOTED OTHERWISE ON SHEAR WALL SCHEDULE) INTERIOR WALL SHEATHING: 1/2" GYPSUM WALL BOARD #6 x 11/4" SCREWS @ 4" O.C. AT PANEL EDGES & 8" O.C. FIELD. (U.N.O.) 1. 2. 3. 4.

FLOOR FRAMING NOTES:


PROVIDE BLOCKING BETWEEN JOISTS OVER BEARING WALLS AND OVER FOUNDATION AT BAY WINDOWS AND FLOOR CANTILEVERS. FLOOR SHEATHING TO BE INSTALLED PERPENDICULAR TO FLOOR JOISTS. USE SIMPSON ITT2 OR IUS HANGERS AT JOIST TO BEAM CONNECTIONS. USE SIMPSON HHUS HANGERS OR APPROVED EQUAL AT BEAM TO BEAM CONNECTIONS (U.N.O.).
E NG INEER:
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF THE SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PRESIDENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

67 psf 12 psf 1.0 95 psf 1.0 40 psf 15 psf 90 MPH II 1.0 C D D 1.0 0.60 0.53

Park Engineering
90 South 200 West Suite #1 Heber City, Utah 84032 Tel. 435.654.1456 www.parkeng.net
(3) 8d (2) 8d (3) 16d @ 16" O.C. (2) 16d (4) 8d TOENAIL or (2) 16d ENDNAIL 16d @ 24" O.C. 16d @ 16" O.C. (2) 16d @ 12" O.C. 16d @ 16" O.C. ALONG EACH EDGE (3) 8d (4) 8d (3) 16d (3) 16d 16d @ 24" O.C. 20d @ 32" O.C. 16d @ 6" O.C.
D R A W I N G S FOR :
2010 PARK ENGINEERING The designs and concepts shown are the sole property of Park Engineering. Not to be copied or reproduced without written permission.

NAILING SCHEDULE (U.N.O.):


1. 2. 3. 4. 5. ALL NAILS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE. JOIST TO SILL PLATE OR GIRDER (TOENAIL) BRIDGING TO JOIST (TOENAIL EA. END) BOTTOM PLATE TO JOIST OR BLOCKING (FACE NAIL) TOP PLATE TO STUD (END NAIL) STUD TO BOTTOM PLATE DOUBLE STUDS (FACENAIL) DOUBLE TOP PLATES (FACE NAIL) TOP PLATES, LAPS & INTERSECTIONS (FACE NAIL) CONTINUOUS HEADER (2 PIECES) ROOF JOIST TO PLATE (TOENAIL) CONTINUOUS HEADER TO STUD (TOENAIL) ROOF JOISTS, LAPS OVER PARTITIONS (FACE NAIL) ROOF JOISTS TO PARALLEL RAFTERS (FACE NAIL) BUILT-UP CORNER STUDS & COLUMNS BUILT-UP BEAMS (FACE NAIL AT TOP & BOTTOM STAGGERED ON OPPOSITE SIDES) RIM JOIST TO TOP PLATE (TOENAIL)

FOUNDATION NOTES:
1. 2. 3. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE CURRENT EDITION OF THE INTERNATIONAL RESIDENTIAL CODE AND LOCAL CODES. 1. ALL FOOTINGS TO BEAR ON UNDISTURBED SOIL OR FILL PER GEOTECHNICAL REPORT. CONTRACTOR SHALL FIELD VERIFY ACTUAL SOILS CONDITIONS BY WAY OF A GEOTECHNICAL SOILS REPORT. ALLOWABLE SOIL BEARING PRESSURE USED PER DESIGN = 1500 PSF. CONTRACTOR TO CONTACT ARCHITECT/ENGINEER PRIOR TO PROCEEDING WITH WORK IF EXPANSIVE CLAY, ORGANIC DEBRIS, OR EXCESSIVE GROUND WATER IS DISCOVERED DURING EXCAVATION. CONTRACTOR TO CONTACT ARCHITECT/ENGINEER IF THE SOIL AT FOOTING ELEVATIONS IS OF QUESTIONABLE BEARING. FOOTINGS TO BEAR AT FROST DEPTH, A MINIMUM OF 36" BELOW FINISHED GRADE. TOP OF FOUNDATION WALLS TO BE A MINIMUM OF 6" ABOVE FINISHED GRADE. BLOCK OUT OPENINGS FOR GARAGE DOORS AS REQUIRED. ALL FOUNDATIONS WILL BE CENTERED ON WALLS OR COLUMNS U.N.O. PROVIDE A WATERPROOFING FOUNDATION COATING ON CONCRETE FOUNDATION WALLS BELOW GRADE. ANCHOR BOLTS DISTANCE FROM EDGE OF FOUNDATION WALLS: FOUNDATION WALLS: 3" WALLS WITH BRICK OR STONE VENEER: 5" THE MAXIMUM SLOPE BETWEEN ADJACENT FOOTINGS OR EXCAVATIONS SHALL NOT EXCEED ON VERTICAL TO TWO HORIZONTAL. STEP FOOTING AS NECESSARY TO MAINTAIN THIS SLOPE. PROVIDE A U-FER GROUND AT PROPOSED LOCATION ON ELECTRICAL PLANS. 12. 14. 15. INSTALL (2) ANCHOR BOLTS 12" APART EVERY 14' OF FOUNDATION WALL FOR SILL PLATE SPLICE. REFER TO ANCHOR BOLT SCHEDULE AND SHEAR WALL LOCATION SCHEDULE FOR ANCHOR BOLT PLACEMENT, SIZE AND SPACING. 13. POSTS (2005 NDS) (POSTS AND TIMBERS) (M.C. NOT TO EXCEED 19%) DOUGLAS FIR-LARCH #1 OR BETTER Fb = 1,200 psi Fcq = 1,000 psi 11. 7. 8. 9. 10. 11. WELDED CONNECTIONS BOLTS ASTM A325N ANCHOR BOLTS EXPANSION BOLTS ASTM A307 or ASTM A36 RED-HEAD ANCHORS, WEDGE-ALL ANCHORS, OR NATIONAL FASTENERS. PROVIDE ICBO REPORT FOR EXPANSION ANCHORS USED. DOUGLAS FIR-LARCH #2 OR BETTER Fb = 900 psi Fcr = 625 psi Fv = 180 psi Fcq = 1,350 psi E = 1,600,000 psi 2.

6.

STRUCTURAL MATERIALS:
CONCRETE SLABS 3000 psi @ 28 DAYS ELSEWHERE 3000 psi @ 28 DAYS REINFORCING STEEL #4-#10 BARS: ASTM A615, GRADE 60 #3 BARS: ASTM A185, GRADE 40 MESH: ASTM A185

7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17.

4.

3. 4.

WELDED BARS AND ANCHORS ASTM A706, GRADE 60 WELDED WIRE AND FABRIC TUBES STEEL SHAPES ASTM A185 ASTM A500, Fy=46 KSI W SHAPES: ASTM A992, Fy=50 KSI OTHER SHAPES: ASTM A36, Fy=36 KSI PLATES: ASTM A36, Fy=36 KSI E70XX ELECTRODES

5. 6.

6. 7. 8. 9. 10.

12.

DIMENSIONAL FRAMING LUMBER (M.C. NOT TO EXCEED 19%)

13.

CONCRETE NOTES
1. 2. 3. 4. 5. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE CURRENT EDITION OF THE INTERNATIONAL RESIDENTIAL CODE AND LOCAL CODES. REINFORCED CONCRETE DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI 318-08.
D R A W I N G T I T L E :

TIMBER MEMBERS (2005 NDS) DOUGLAS FIR-LARCH #2 OR BETTER (BEAMS AND STRINGERS) Fb = 875 psi Fcr = 625 psi (M.C. NOT TO EXCEED 19%) Fv = 170 psi Fcq = 600 psi E = 1,300,000 psi DOUGLAS FIR-LARCH #1 OR BETTER Fb = 1,350 psi Fcr = 625 psi Fv = 170 psi Fcq = 925 psi E = 1,600,000 psi

CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO STARTING CONSTRUCTION. ALL SLABS ON GRADE ARE TO BE PLACED ON COMPACTED BACKFILL. ALL REINFORCING STEEL SHALL BE NEW GRADE 60 DEFORMED BARS AND SHALL BE TIED IN PLACE PRIOR TO POURING CONCRETE. REINFORCING STEEL CONCRETE COVER: SURFACE CAST AGAINST EARTH: 3"
P R O J E C T D R A W N # :

14.

LVL MEMBERS (I-LEVEL TRUSS JOIST OR EQUIVALENT) GLU-LAM BEAMS (2005 NDS)

Fb = 2600 psi Fv = 285 psi E = 1,800,000 psi 24F-V4 DF/DF Fb = 2,400 psi Fv = 265 psi E = 1,800,000 psi

Fcr = 750 psi Fcq = 2,510 psi

STRUCTURAL NOTES

ROOF FRAMING NOTES


1. 2. 3. 4. 5. 6. ALL TRUSSES TO BE SECURED ON EACH END w/ SIMPSON H-1 CLIPS AND GIRDER TRUSSES w/ LGT HOLDOWNS AT EACH END (U.N.O.). PROVIDE SOLID BLOCKING BETWEEN TRUSSES AND RAFTERS OVER BEARING WALLS. USE SIMPSON ITT TOP FLANGE HANGERS AT ALL RAFTER TO BEAM CONNECTIONS (U.N.O.). PROVIDE SOLID BLOCKING UNDER ALL GIRDER TRUSSES AND BEAMS TO FOUNDATION. TRUSS BLOCKING SHALL BE NAILED SOLID TO SHEATHING WITH NAILING THROUGH SHEATHING INTO BLOCKING. VALLEY AND HIP RAFTERS ARE NOT TO BE LESS THAN 2" THICK AND NOT LESS IN DEPTH THAN THE CUT END OF THE RAFTER.

15.

Fcr = 650 psi Fcq = 1,650 psi

6.

16. 17.

JOISTS

I-LEVEL TRUSS JOIST, LOUISIANA PACIFIC, OR EQUIV. (INSTALL PER MFR's SPEC's)

LOG MEMBERS DOUGLAS FIR-LARCH #1 OR BETTER (T.P.I. GRADED AND STAMPED) Fb = 1200 psi Fcr = 625 psi (M.C. NOT TO EXCEED 19%) Fv = 180 psi Fcq = 1,550 psi E = 1,800,000 psi 7. 8. 9. 10. 11.

FORMED SURFACES IN CONTACT WITH EARTH OR EXPOSED TO WEATHER: #5 OR SMALLER: 2" #6 OR LARGER: 11/2" FORMED SURFACES NOT IN CONTACT WITH EARTH OR EXPOSED TO WEATHER WALLS, SLABS, JOISTS: 3/4" TOP OF FOUNDATION WALLS TO BE A MINIMUM OF 6" ABOVE FINISHED GRADE. BLOCK OUT OPENINGS FOR GARAGE DOORS AS REQUIRED. ALL CONCRETE EXPOSED TO FREEZING AND THAWING SHALL CONTAIN 5-7% ENTRAINED AIR. ALUMINUM CONDUIT OR PIPING MAY NOT BE EMBEDDED IN ANY CONCRETE. CALCIUM CHLORIDE IS NOT ALLOWED AS AN ADDITIVE TO CONCRETE MIX.

B Y : B Y :

C H E C K E D SCALE :

18. ERRORS AND OMISSION WHICH MAY OCCUR IN THE CONTRACT DOCUMENTS AND PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER, IN WRITING AND WRITTEN INSTRUCTION SHALL BE OBTAINED PRIOR TO PROCEEDING WITH CONSTRUCTION. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ANY ERRORS, DISCREPANCIES OR OMISSIONS FOR WHICH THE CONTRACTOR FAILED TO NOTIFY THE ENGINEER PRIOR TO CONSTRUCTION AND OR FABRICATION OF THE WORK.

NOTE: IF THIS DRAWING IS NOT 36" x 24", IT HAS BEEN REVISED FROM ITS ORIGINAL SIZE. SCALE IS NO LONGER APPLICABLE.

SEAL :

D R A W I N G

N O :

S1.0

LOT 53, Dutch Fields Midway, UT 84049


Project Number NT SJP 1/4" = 1'-0"

5.

NICHOLS RESIDENCE

NO

DATE

ISSUE

FOUNDATION WALL REINFORCING


VERTICAL REINFORCING

FOOTING SCHEDULE Loc Footing Name 36 in Strip Footing 24 in Strip Footing 20 in Strip Footing 60 in x 84 in Spot Footing 36 in x 36 in Spot Footing 30 in x 48 in Spot Footing Footing Type 36in x 10in x Cont Footing w/ (3) #4 bar 24in x 10in x Cont Footing w/ (2) #4 bar 20in x 10in x Cont Footing w/ (2) #4 bar 60in x 84in x 10in Footing w/ (6) #4 bar each way 36in x 36in x 10in Footing w/ (5) #4 bar each way 30in x 48in x 10in Footing w/ (3) #4 bar each way Remarks LOC AB-1 AB-2 AB-3 AB-4 AB-5 AB-6 Bolt Type 5/8" Standard 5/8" Standard 5/8" Standard 5/8" Standard 5/8" Standard 5/8" Standard Spacing 32 24 16" 12" 24" 12"

ANCHOR BOLT SCHEDULE Washer 3" x 3" x 1/4" 3" x 3" x 1/4" 3" x 3" x 1/4" 3" x 3" x 1/4" 3" x 3" x 1/4" 3" x 3" x 1/4" HOLD DOWN SCHEDULE LOC AA BB CC DD EE Description MST37 MST48 STHD14/14RJ HDU5 MST60 INTO (2) INTO (2) INTO (2) INTO (2) INTO (2) Notes STUDS STUDS STUDS STUDS STUDS MIN. MIN. MIN. MIN. MIN. Sill Plate 2x 2x 2x 2x 3x 3x Strength (plf) 292 350 438 584 744 1488

8" x 4' WALL

#4 @ 24" o.c. Verticals #4 @ 16" o.c. Horizontals #4 within top and bottom of wall #4 @ 24" o.c. Verticals #4 @ 16" o.c. Horizontals #4 within top and bottom of wall #4 @ 16" o.c. Verticals #4 @ 16" o.c. Horizontals #4 within top and bottom of wall #4 @ 12" o.c. Verticals #4 @ 16" o.c. Horizontals #4 within top and bottom of wall
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF THE SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PRESIDENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

CORNER LAP BAR TO MATCH HORIZONTAL REINFORCEMENT (MIN. LAP 3'-0" EACH WAY)

HORIZONTAL REINFORCING

F-1 F-2 F-3 F-4 F-5 F-6

8" x 8' WALL

8" x 9' WALL

F5

F5

8" x 10' WALL

E NG INEER:

FOUNDATION WALL CORNER 1/4" = 1'-0"

10 A6.1

20 A6.1

12" SONOTUBE (TYPICAL) F2 F1 F2

Park Engineering
90 South 200 West Suite #1 Heber City, Utah 84032 Tel. 435.654.1456 www.parkeng.net
2010 PARK ENGINEERING The designs and concepts shown are the sole property of Park Engineering. Not to be copied or reproduced without written permission.

F5 F2 F3 F2 F2

F5

F1

F1

F1

F3 F4 F3

F2 F3

F3

FURN

F3

F5

W/H
F3 F2 F3

E/T

W/H

E/T

F3 F2 F5

D R A W I N G

T I T L E :

SQUARE OR ROUND WOOD POST 1/4" STEEL KNIFE PLATE

F5

FOOTING / FOUNDATION PLAN


F1 UFER GROUND
P R O J E C T D R A W N # :

B Y : B Y :

GRADE

1/2" BOLTS

C H E C K E D

F1
(3) #3 BAR WITHIN TOP 5"

F1
SCALE :

36" MIN.

(3) #4 VERT BAR

#3 TIES @ 8" O.C.

F1

NOTE: IF THIS DRAWING IS NOT 36" x 24", IT HAS BEEN REVISED FROM ITS ORIGINAL SIZE. SCALE IS NO LONGER APPLICABLE.

12" SONOTUBE

PLACE ON UNDISTURBED SOIL OR SELECT FILL COMPACTED TO 95% RELATIVE DENSITY

F5

F5 F6 F6

F5

F5

SEAL :

F6
SEE FOOTING SCHEDULE FOR FOOTING SIZE

F6

SONOTUBE DETAIL 2 1/4" = 1'-0"

12" SONOTUBE (TYPICAL)

Footing/Foundation Plan
SCALE: 1/4" = 1'-0"

D R A W I N G

N O :

S1.1

LOT 53, Dutch Fields Midway, UT 84049


Project Number NT SJP 1/4" = 1'-0"

Unexcavated
D R A W I N G S FOR :

NICHOLS RESIDENCE

F5

NO

DATE

ISSUE

BEAM SCHEDULE Loc B-1 B-2 B-3 B-4 B-5 B-6 B-7 B-8 B-9 B-10 B-11 B-12 B-13 B-14 B-15 Beam Name 4' UPPER LEVEL HEADERS LARGE WINDOW HEADER MAIN FLOOR HEADER 6' MAIN HEADER GREAT ROOM WINDOW HEADER PORCH FLOOR BEAMS DINING BEAM PORCH ROOF BEAMS FLOOR HEADER 9' FLOOR HEADERS GARAGE DOOR HEADER 3' BASEMENT HEADER 5' BASEMENT HEADER 16' FLOOR BEAM DECK ANGLE BEAMS Beam Type (3) 2 x 10 DF-L #2 (2) 1.75 x 9.25 LVL (3) 2 x 12 DF-L #2 (3) 1.75 x 9.25 LVL (3) 1.75 x 18 LVL (1) 3.125 x 10.5 GLB (1) 6.75 x 22.5 GLB (1) 3.125 x 9 GLB (2) 2 x 10 DF-L #2 (2) 1.75 x 11.875 LVL (3) 1.75 x 9.25 LVL (2) 2 x 10 DF-L #2 (2) 1.75 x 9.25 LVL (3) 1.75 x 16 LVL (2) 2 x 10 DF-L #2 Trimmer 2 2 2 3 C-1 2 C-2 1 1 2 1 2 2 2 1 Remarks Loc C-1 C-2 Option: (2) 1.75 x 9.25 LVL SEE STEEL OPTION Option: (2) 1.75 x 9.25 LVL Option: (1) 1.75 x 11.25 LVL Option: (1) 6 x 10 DF-L #2 SEE STEEL OPTION SEE STEEL OPTION Column Name (3) 2in x 6in DF-L #2 (4) 2in x 6in DF-L #2

COLUMN SCHEDULE Column Type (3) 2in x 6in DF-L #2 (4) 2in x 6in DF-L #2 Remarks Built-up Column Built-up Column Loc SB-1 SB-2 SB-3 Beam Name B-5 STEEL OPTION B-7 STEEL OPTION B-14 STEEL OPTION

STEEL BEAM SCHEDULE Beam Type W10x60 W10x60 W10x22 FLOOR JOIST SCHEDULE Loc FJ-1 FJ-2 FJ-3 Joist Name 18' FLOOR JOISTS 20' FLOOR JOISTS DECK JOISTS Joist (1) 11.875in 210 TJI Joist(s) @ 16in O.C. (1) 11.875in 210 TJI Joist(s) @ 16in O.C. (1) 2in x 10in DF#2 Joists(s) @ 16in O.C. Remarks

NOTE: ALL HEADERS IN BEARING WALLS OR EXTERIOR WALL TO BE (2) 2x10 DF#2 U.N.O

ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF THE SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PRESIDENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

E NG INEER:

12x12 COLUMN (TYPICAL) FJ-1

Park Engineering
90 South 200 West Suite #1 Heber City, Utah 84032 Tel. 435.654.1456 www.parkeng.net
2010 PARK ENGINEERING The designs and concepts shown are the sole property of Park Engineering. Not to be copied or reproduced without written permission.

10 A6.1

20 A6.1

DECKING OVER 8" SLAB w/ #4 BAR @ 16" O.C. EACH WAY

12x12 COLUMN (TYPICAL) B-6

B-6

B-15

B-14 LSL RIM BOARD (TYPICAL)

B-6

NICHOLS RESIDENCE
D R A W I N G # : B Y : B Y : SEAL : D R A W I N G

HANG DECK JOISTS w/ LUS26 (TYPICAL) B-6

B-12

FURN
B-12 4x4 POST w/ MST 48 STRAP FROM LVL TO POST & HTT 22 FROM POST TO FOOTING FJ-3

B-12

B-13

B-13

W/H

E/T

W/H

E/T

B-12 B-6

T I T L E :

LEDGER:

ROOF OVERBUILD RAFTERS JOIST HANGERS

FRAMING PLAN MAIN FLOOR


P R O J E C T

BEAM or HEADER w/TRIMMERS COLUMN FJ-3 B-6 OVERLAPPING OVERHANG

D R A W N

C H E C K E D SCALE :

NOTE: IF THIS DRAWING IS NOT 36" x 24", IT HAS BEEN REVISED FROM ITS ORIGINAL SIZE. SCALE IS NO LONGER APPLICABLE.

ROOF OVERBUILD B-15

SHEATHING ORIENTATION

B-6

B-6

B-6

B-6 DECK LEDGER: 2x10 DF#2 w/ (3) SIMPSON SDS SCREWS @ 16" O.C.

(2) LVLs UNDER SHEAR WALL

B-6

B-6

B-6

BEARING WALL

FRAMING PLAN - Main FLoor


SCALE: 1/4" = 1'-0"
N O :

S1.2

LOT 53, Dutch Fields Midway, UT 84049


Project Number NT SJP 1/4" = 1'-0"

D R A W I N G S FOR :

FJ-2

NO

DATE

ISSUE

BEAM SCHEDULE Loc B-1 B-2 B-3 B-4 B-5 B-6 B-7 B-8 B-9 B-10 B-11 B-12 B-13 B-14 B-15 Beam Name 4' UPPER LEVEL HEADERS LARGE WINDOW HEADER MAIN FLOOR HEADER 6' MAIN HEADER GREAT ROOM WINDOW HEADER PORCH FLOOR BEAMS DINING BEAM PORCH ROOF BEAMS FLOOR HEADER 9' FLOOR HEADERS GARAGE DOOR HEADER 3' BASEMENT HEADER 5' BASEMENT HEADER 16' FLOOR BEAM DECK ANGLE BEAMS Beam Type (3) 2 x 10 DF-L #2 (2) 1.75 x 9.25 LVL (3) 2 x 12 DF-L #2 (3) 1.75 x 9.25 LVL (3) 1.75 x 18 LVL (1) 3.125 x 10.5 GLB (1) 6.75 x 22.5 GLB (1) 3.125 x 9 GLB (2) 2 x 10 DF-L #2 (2) 1.75 x 11.875 LVL (3) 1.75 x 9.25 LVL (2) 2 x 10 DF-L #2 (2) 1.75 x 9.25 LVL (3) 1.75 x 16 LVL (2) 2 x 10 DF-L #2 Trimmer 2 2 2 3 C-1 2 C-2 1 1 2 1 2 2 2 1 Remarks Loc C-1 C-2 Option: (2) 1.75 x 9.25 LVL SEE STEEL OPTION Option: (2) 1.75 x 9.25 LVL Option: (1) 1.75 x 11.25 LVL Option: (1) 6 x 10 DF-L #2 SEE STEEL OPTION SEE STEEL OPTION Column Name (3) 2in x 6in DF-L #2 (4) 2in x 6in DF-L #2

COLUMN SCHEDULE Column Type (3) 2in x 6in DF-L #2 (4) 2in x 6in DF-L #2 Remarks Built-up Column Built-up Column Loc SB-1 SB-2 SB-3 Beam Name B-5 STEEL OPTION B-7 STEEL OPTION B-14 STEEL OPTION

STEEL BEAM SCHEDULE Beam Type W10x60 W10x60 W10x22 FLOOR JOIST SCHEDULE Loc FJ-1 FJ-2 FJ-3 Joist Name 18' FLOOR JOISTS 20' FLOOR JOISTS DECK JOISTS Joist (1) 11.875in 210 TJI Joist(s) @ 16in O.C. (1) 11.875in 210 TJI Joist(s) @ 16in O.C. (1) 2in x 10in DF#2 Joists(s) @ 16in O.C. Remarks

NOTE: ALL HEADERS IN BEARING WALLS OR EXTERIOR WALL TO BE (2) 2x10 DF#2 U.N.O

ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF THE SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PRESIDENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

E NG INEER:

B-8

10 A6.1

20 A6.1

Park Engineering
90 South 200 West Suite #1 Heber City, Utah 84032 Tel. 435.654.1456 www.parkeng.net
B-8
2010 PARK ENGINEERING The designs and concepts shown are the sole property of Park Engineering. Not to be copied or reproduced without written permission.

RR-1

B-1

B-1

B-1

B-1

B-1

B-8

B-8

B-11

B-4

B-8

B-8

C-1

C-1

B-8

B-7 C-2 C-2

B-5

B-4 B-3

NICHOLS RESIDENCE
D R A W I N G # : B Y : B Y : SEAL : D R A W I N G

PRE-ENGINEERED TRUSSES

@ 24" O.C.

B-11

B-10 B-9

B-9

ATTIC ACCESS

B-3

B-10

B-3

WASH

B-10

B-10

B-9

B-9 B-8 CANTILEVER JOISTS

DRY

B-3

FJ-1

T I T L E :

B-8

B-3

ROOF OVERBUILD RAFTERS


P R O J E C T

B-4

FRAMING PLAN UPPER FLOOR


Project Number NT SJP 1/4" = 1'-0"

JOIST HANGERS
D R A W N

BEAM or HEADER w/TRIMMERS B-3 COLUMN B-3 OVERLAPPING OVERHANG B-3 ROOF OVERBUILD B-8 B-3 B-3 B-4 LEDGER: 2x10 w/(4) SIMPSON SDS SCREWS @ 24" O.C. B-3 B-3 B-3 B-8

C H E C K E D SCALE :

NOTE: IF THIS DRAWING IS NOT 36" x 24", IT HAS BEEN REVISED FROM ITS ORIGINAL SIZE. SCALE IS NO LONGER APPLICABLE.

SHEATHING ORIENTATION

B-8

B-8

B-8

B-8

B-8

B-8

B-8

B-8

CANTILEVER JOISTS

HANG w/ SIMPSON MUS28

GIRDER TRUSS BEARING WALL


N O :

FRAMING PLAN - Upper Floor


SCALE: 1/4" = 1'-0"

PRE-ENGINEERED JACK TRUSSES @ 24" O.C.

S1.3

LOT 53, Dutch Fields Midway, UT 84049

B-8

D R A W I N G S FOR :

NO

DATE

ISSUE

BEAM SCHEDULE Loc B-1 B-2 B-3 B-4 B-5 B-6 B-7 B-8 B-9 B-10 B-11 B-12 B-13 B-14 B-15 Beam Name 4' UPPER LEVEL HEADERS LARGE WINDOW HEADER MAIN FLOOR HEADER 6' MAIN HEADER GREAT ROOM WINDOW HEADER PORCH FLOOR BEAMS DINING BEAM PORCH ROOF BEAMS FLOOR HEADER 9' FLOOR HEADERS GARAGE DOOR HEADER 3' BASEMENT HEADER 5' BASEMENT HEADER 16' FLOOR BEAM DECK ANGLE BEAMS Beam Type (3) 2 x 10 DF-L #2 (2) 1.75 x 9.25 LVL (3) 2 x 12 DF-L #2 (3) 1.75 x 9.25 LVL (3) 1.75 x 18 LVL (1) 3.125 x 10.5 GLB (1) 6.75 x 22.5 GLB (1) 3.125 x 9 GLB (2) 2 x 10 DF-L #2 (2) 1.75 x 11.875 LVL (3) 1.75 x 9.25 LVL (2) 2 x 10 DF-L #2 (2) 1.75 x 9.25 LVL (3) 1.75 x 16 LVL (2) 2 x 10 DF-L #2 Trimmer 2 2 2 3 C-1 2 C-2 1 1 2 1 2 2 2 1 Remarks Loc C-1 C-2 Option: (2) 1.75 x 9.25 LVL SEE STEEL OPTION Option: (2) 1.75 x 9.25 LVL Option: (1) 1.75 x 11.25 LVL Option: (1) 6 x 10 DF-L #2 SEE STEEL OPTION SEE STEEL OPTION Column Name (3) 2in x 6in DF-L #2 (4) 2in x 6in DF-L #2

COLUMN SCHEDULE Column Type (3) 2in x 6in DF-L #2 (4) 2in x 6in DF-L #2 Remarks Built-up Column Built-up Column Loc SB-1 SB-2 SB-3 Beam Name B-5 STEEL OPTION B-7 STEEL OPTION B-14 STEEL OPTION

STEEL BEAM SCHEDULE Beam Type W10x60 W10x60 W10x22 FLOOR JOIST SCHEDULE Loc FJ-1 FJ-2 FJ-3 Joist Name 18' FLOOR JOISTS 20' FLOOR JOISTS DECK JOISTS Joist (1) 11.875in 210 TJI Joist(s) @ 16in O.C. (1) 11.875in 210 TJI Joist(s) @ 16in O.C. (1) 2in x 10in DF#2 Joists(s) @ 16in O.C.
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF THE SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PRESIDENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

Remarks

NOTE: ALL HEADERS IN BEARING WALLS OR EXTERIOR WALL TO BE (2) 2x10 DF#2 U.N.O

E NG INEER:

Park Engineering
90 South 200 West Suite #1 Heber City, Utah 84032 Tel. 435.654.1456 www.parkeng.net
2010 PARK ENGINEERING The designs and concepts shown are the sole property of Park Engineering. Not to be copied or reproduced without written permission.

STRAP OVER RIDGE BEAM TO EACH RAFTER w/ 20" OF CS18 STRAP

PRE-ENGINEERED TRUSSES @ 24" O.C.

SUPPORT OVERBUILD RIDGE EVERY 6'

10 A6.1

20 A6.1

ROOF BOUNDARY NAILING

B-2
2x OVERBUILD RAFTERS SHEATH MAIN ROOF PRIOR TO OVERBUILD (TYP)

B-1

B-1

B-2

JOIST OR RAFTERS (PER FRAMING PLANS)

2 X 4 DF-L #2 2 X 6 DF-L #2 2 X 8 DF-L #2 2 X 10 DF-L #2

3 Feet 5 Feet 8 Feet 10 Feet

All Spans over 10 Feet to be supported at midspan.

ROOF OVERBUILD DETAIL 1/4" = 1'-0"

ATTIC ACCESS

WASHER DRYER COMBO

B-1

ROOF OVERBUILD RAFTERS JOIST HANGERS BEAM or HEADER w/TRIMMERS COLUMN

ATTIC ACCESS

B-1

D R A W I N G S FOR :

Rafter

Maximum Span

D R A W I N G

T I T L E :

OVERLAPPING OVERHANG

B-1

B-2

ROOF OVERBUILD

FRAMING PLAN ROOF


P R O J E C T # :

SHEATHING ORIENTATION
D R A W N B Y : B Y : C H E C K E D

B-1

B-2

SCALE :

NOTE: IF THIS DRAWING IS NOT 36" x 24", IT HAS BEEN REVISED FROM ITS ORIGINAL SIZE. SCALE IS NO LONGER APPLICABLE.

B-2
SEAL :

B-2 BEARING WALL B-2 GIRDER TRUSS

FRAMING PLAN - Roof


SCALE: 1/4" = 1'-0"

D R A W I N G

N O :

S1.4

LOT 53, Dutch Fields Midway, UT 84049


Project Number NT SJP 1/4" = 1'-0"

2x10 OR SIMILAR NAILERS NAILED w/ (6) 16d NAILS EA. TRUSS OR RAFTER

Over Build Framing (30 lbs Snow)

NICHOLS RESIDENCE

B-1

HOLD DOWN SCHEDULE LOC AA BB CC DD EE Description MST37 MST48 STHD14/14RJ HDU5 MST60 Notes INTO (2) STUDS MIN. INTO (2) STUDS MIN. INTO (2) STUDS MIN. INTO (2) STUDS MIN. INTO (2) STUDS MIN. Notes: 1. All Studs for shear walls shall be 16" o/c unless noted otherwise. 2. 16d common nail transfer through sill. 3. Staples must be placed with axis parallel to framing member. 4. Minimum anchor bolt size should be AB-1 if not specified. 5. All anchor bolts should be embedded 7" minimum and should be positioned between two rebar. 6. Holddowns and straps should be "Simpson Strong-tie" brand. 7. All holddowns and straps should be attached per manufacturer's specifications to a minimum of two full height studs. Trimmers should not be used to attach to. WALL 13 Loc Wall 1 Wall 2 Wall 3 Wall 4 Wall 5 Wall 6 Wall 7 Wall 8 Wall 9 Wall 10 Wall 11 Wall 12 Wall 13 Wall 14 Wall 15 Wall 16 Wall 17 Wall 18 Description

SHEAR WALL LOCATION SCHEDULE Shear Wall SW-2 SW-2 SW-2 SW-1 SW-2 SW-1 SW-1 SW-4 SW-5 SW-4 SW-5 SW-4 SW-5 SW-3 SW-2 SW-1 SW-5 SW-1 Floor Tie MST 37 MST 60 none MST 37 MST 48 none MST 37 none none none none none none none none none none none
STUD WALL

SHEAR WALL SCHEDULE Hold Down none none none none none none none STHD14RJ STHD14RJ STHD14RJ STHD14RJ STHD14RJ STHD14RJ STHD14RJ STHD14RJ none STHD14 none Anchor Bolts AB-1 AB-3 AB-1 AB-1 AB-3 AB-1 AB-1 AB-1 AB-4 AB-4 AB-4 AB-2 AB-4 AB-4 AB-3 AB-1 AB-5 AB-1 LOC SW-1 SW-2 SW-3 SW-4 SW-5 SW-6 -orDescription Sheathing 7/16" OSB 7/16" OSB 7/16" OSB 7/16" OSB 7/16" OSB 7/16" OSB 19/32" OSB Both Sides NO NO NO NO NO YES NO Edge Stud 2X4 2X4 2X4 2x flat or 4x 2x flat or 4x 2x flat or 4x 2x flat or 4x Size 8d 8d 8d 8d 8d 8d 10d Nailing Edge 6" 4" 3 3" 2" 4" 4" Field 12" 12" 12" 12" 12" 12" 12" Staples Edge 3" 2" no no no no no Field 12" 12" no no no no no Strength (plf) 280 430 490 550 730 860 870

NO

DATE

ISSUE

WALL 16

CC WALL 15

WALL 13 CC CC CC

CC

UPPER - LOFT UPPER - FRONT JOG UPPER - FRONT WALL UPPER - INTERIOR STAIR WALL UPPER - RIGHT SIDE WALL UPPER - REAR WALL UPPER - LEFT WALL FRONT MUD WALL FRONT JOG WALL FRONT WALL INTERIOR STAIR WALL RIGHT SIDE WALL REAR GRT WALL INTERIOR GARAGE DINING SIDE WALL REAR DINING GARAGE GARAGE - PIERS FRONT GARAGE

ANCHOR BOLT SCHEDULE LOC AB-1 AB-2 AB-3 AB-4 AB-5 AB-6 Bolt Type 5/8" Standard 5/8" Standard 5/8" Standard 5/8" Standard 5/8" Standard 5/8" Standard Spacing 32 24 16" 12" 24" 12" Washer 3" x 3" x 1/4" 3" x 3" x 1/4" 3" x 3" x 1/4" 3" x 3" x 1/4" 3" x 3" x 1/4" 3" x 3" x 1/4" Sill Plate 2x 2x 2x 2x 3x 3x Strength (plf) 292 350 438 584 744 1488
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF THE SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PRESIDENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

E NG INEER:

CC
FLOOR SHEATHING RIM BOARD

CC WALL 17
HOSE BIBS

NAIL SHEATHING TO RIM BOARD PER SHEARWALL PLAN EDGE NAILING. (TREAT RIM BOARD AS EDGE)

Park Engineering
10d @ 6" O.C.
10d NAIL @ 3" O.C. ALL AROUND 16d ALL AROUND 2x BLOCKING TO PFT. 1/2" PL Y WOOD P ANE L 2x4 BLKG ALL AROUND PFT @ 24" O.C. 16d @ 16" O.C. TOP PLATES 10d @ 6" O.C. TRUSS SHALL BE DESIGNED TO BEAR ON BEAM AS SHOWN HEADER WHERE OCCURS

CC
WALL SHEATHING PER PLAN

CC
WASH

JOIST PER PLAN

90 South 200 West Suite #1 Heber City, Utah 84032 Tel. 435.654.1456 www.parkeng.net
2010 PARK ENGINEERING The designs and concepts shown are the sole property of Park Engineering. Not to be copied or reproduced without written permission.

WALL 14

CC
DRY

WALL 12

CC WALL 11

SHEAR TRANSFER (PERPENDICULAR) 1/4" = 1'-0"


EDGE NAILING PER PLAN

CC WALL 9 CC CC

CC

PRE-ENGINEERED TRUSS DESIGNED TO TRANSFER LOAD BY MANUF. A35 EA. SIDE OF BLOCK

CC

CC

WALL SHEATHING -SEE SHEAR WALL SCHED.

3
2x8 BLOCKING @ 24" O.C. (3) SIMPSON 1 1 SDS _ "x4_ " EA. BLOCK
4 2

WALL 18

WALL 8

WALL 10

SHEAR PLAN - Main Level


SCALE: 1/8" = 1'-0"

SHEAR TRANSFER AT TRUSSES (PARALLEL) 1/4" = 1'-0"

WALL 6

CC

CC

CC AA AA

CC

CC

CC
D R A W I N G T I T L E :

CC
WASHER DRYER COMBO

AA

SHEAR PLANS
WALL 5

CC
FURN

WALL 7

AA

AA

P R O J E C T D R A W N

# :

B Y : B Y :

W/H

E/T

W/H

E/T

C H E C K E D

CC

WALL 4

CC CC AA WALL 2 AA

AA

SCALE :

NOTE: IF THIS DRAWING IS NOT 36" x 24", IT HAS BEEN REVISED FROM ITS ORIGINAL SIZE. SCALE IS NO LONGER APPLICABLE.

AA

AA

SEAL :

CC CC CC CC CC

WALL 1

WALL 3

D R A W I N G

N O :

SHEAR PLAN - Lower Level


SCALE: 1/8" = 1'-0"

SHEAR PLAN - Upper Level


SCALE: 1/8" = 1'-0"

S1.5

LOT 53, Dutch Fields Midway, UT 84049


Project Number NT SJP As indicated

2x4 SHEARWALL PER PLAN


D R A W I N G S FOR :

NICHOLS RESIDENCE

SHEAR TRANSFER AT TRUSSES (PERPENDICULAR) 1/4" = 1'-0"

3/4" T&G WFR. BRD. SHEATHING FLOOR JOISTS PER FRAMING PLANS

NO

DATE

ISSUE

30d NAILS or SIMPSON SDS _ " x 4 _ " 4 4 SCREW DRIVEN ON OPPOSITE FACES AS SHOWN (4) 1/2" x 5" LAG SCREWS EVENLY SPACED

INSULATION GYPSUM BOARD

2x STUD WALL W/ SHEETING & VAPOR BARRIER 1" AIR SPACE

SECTION A-A
DOUBLE TOP PLATE BLOCKING BETWEEN FLOOR JOISTS 3_"
1 2

2x6 STUD STACK

TIES @ 16" O.C.


ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF THE SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PRESIDENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

8"

FIRE BLOCKING @ WALL MIDHEIGHT (STAGGERED) 2x INTERIOR BEARING WALL 2x TREATED SILL PLATE
1 " 2 (TYP)
1 _

STONE VENEER DRIP EDGE

E NG INEER:
PROVIDE WEEP HOLES TREATED SILL PLATE 2 _"
2 1

5/8" x 10" ANCHOR BOLT (PER SHEAR WALL SCHEDULE) 4" CONC. SLAB (18" MIN FOR SHEAR WALLS)

GRADE

A
_ " x 4_ 30d NAILS or SIMPSON SDS 4 4" SCREWS DRIVEN ON OPPOSITE FACES AS SHOWN IN SECTION A-A. 1 (NOTE: USE SIMPSON SDS _ " x 6" 4 1 1

ANCHOR BOLT FOUNDATION WALL W/ REINFORCING

Park Engineering
3x3X1/4 GALV. ANGLE w/ 5/8" WEDGE-ALL ANCHORS @ 24" O.C.

20"x10" THICKENED SLAB FOOTING

GRAVEL FILL

COMPACTED FILL OR UNDISTURBED EARTH

NOTE: MIN. STUD STACK UNDER ALL POINT LOADS IS (3) 2x6 TYP. (U.N.O.)

SCREWS @ (4) PLY STUD STACK)

90 South 200 West Suite #1 Heber City, Utah 84032 Tel. 435.654.1456 www.parkeng.net
2010 PARK ENGINEERING The designs and concepts shown are the sole property of Park Engineering. Not to be copied or reproduced without written permission.

BEAM TO COLUMN 1/4" = 1'-0"

BEARING WALL TO FOOTING 1/4" = 1'-0"

BUILT-UP COLUMN DETAIL 1/4" = 1'-0"

STONE VENEER TO WALL DETAIL 1/4" = 1'-0"

HEADER AS PER PLAN NAIL KING STUD TO GARAGE HEADER w/ (6) 16d NAILS STAGGERED

4'-0" TYP.

FLASHING NOTES:
1- LINE-WIRE, WHEN USED AS BACKING TO SUPPORT BUILDING PAPER BENEATH WIRE LATH (NETTING) FOR PORTLAND CEMENT (STUCCO), SHALL BE INSTALLED, AS FOLLOWS: DECK LEDGER
2x6 REDWOOD OR TREX DECKING

16d NAILS @ 3" STAGGERED NAILED THRU BLOCKING AND INTO HEADER

NO ATTACHMENT DEVICES NOR THE WIRE BACKING SHALL COVER OR PENETRATE THE FLASHING MATERIAL. 2 - FLASHING TO BE A MINIMUM OF 6" WIDE. 3 - PROVIDE SEALANT AS RECOMMENDED BY WINDOW MANUFACTURER PRIOR TO INSTALLATION OF WINDOW OR SLIDING DOOR.

SIMPSON MST37 STRAP (TYP) NOTCH SHEATHING AROUND EDGES SHEATHING JOINT

(2) 1/2" THRU-BOLTS AT 16" O.C. TJI FLOOR JOIST

SIMPSON STRAP (TYP.) BLOCKING @ SHEATHING JOINTS

DECK JOIST (PER PLAN)

PERIPHERAL FLASHING AT ALL EDGES OF WALL OPENINGS MUST COVER THE WIRE BACKING.

STEP 1
LINTEL
4 . 0 0

STEP 2
LINTEL WINDOW (2) 2x4

USE DOUBLE 2" SILL PLATE w/ 12" ANCHOR BOLTS MIN. 7" EMBEDMENT

WINDOW ROUGH OPENING LAP SHEATHING ONTO RIM BOARD SIMPSON JOIST HANGER SILL
1 "

ROUGH OPENING

4"-12" FROM EDGE (TYP.) (MINIMUM OF 2 BOLTS)

SQUARE OR ROUND WOOD POST


8 "

7
ATTACH SILL STRIP WITH TOP EDGE LEVEL WITH, ROUGH SILL, EXTEND BEYOND EDGE OF ROUGH OPENING 8" MIN. SECURE ALL APPROVED FLASHING MATERIAL W/ GALVANIZED NAILS OR POWER-DRIVEN STAPLES. ATTACH JAMB STRIPS WITH SIDE EDGE EVEN WITH ROUGH JAMB FRAMING, START STRIP 1" BELOW LOWER EDGE OF SILL STRIP AND EXTEND 4" ABOVE LOWER EDGE OF LINTEL.

NARROW WALL DETAIL 1/4" = 1'-0"

1/4" STEEL KNIFE PLATE

NOTES:
1. NO PENETRATIONS IN FLASHING. 2. PROVIDE ISOLATOR BETWEEN ANY DISSIMILAR METALS. 3. PLUMBING VENT IS SIMILAR. 4. PROVIDE STRAPPING PER MANUF. SPECS. 5. ALLOW MIN. 1" TO COMBUSTIBLE SURFACES WHERE PIPE MEETS ROOF, TRUSS CHORDS, AND/OR CEILING AND FLOOR JOISTS. 6. PROVIDE DRAFT STOPPING

G.I. CAP 'B' VENT PROVIDE DRAW BAND W/ HEAT RESISTANT SEALANT.

1/2" BOLTS

D R A W I N G

T I T L E :

GRADE
(3) #3 BAR WITHIN TOP 5"

(UP TO 7:12 ROOF SLOPE)

STEP 3

STEP 4
C

B
#3 TIES @ 8" O.C.

12" MIN.

DETAILS

P R O J E C T D R A W N

# :

36" MIN.

2 "

B Y : B Y :

(3) #4 VERT BAR

A
P LA 3"
ALUM. PITCH FLASHING

C H E C K E D SCALE :

NOTE: IF THIS DRAWING IS NOT 36" x 24", IT HAS BEEN REVISED FROM ITS ORIGINAL SIZE. SCALE IS NO LONGER APPLICABLE.

PLACE ON UNDISTURBED SOIL OR SELECT FILL COMPACTED TO 95% RELATIVE DENSITY

INSTALL WINDOW INTO ROUGH OPENING WITH SILL AND JAMB FLANGES OVER PREVIOUSLY INSTALLED FLASHING. ATTACH HEAD FLASHING OVER THE WINDOW FLANGE.

COMMENCING AT THE BOTTOM (SOLE PLATE) OF THE WALL, LAY BUILDING PAPER UNDER SILL STRIP. NOTE: CUT ANY EXCESS BUILDING PAPER THAT MAY EXTEND ABOVE THE SILL FLANGE LINE ON EA. SIDE OF THE OPENING (SHOWN AS DASHED LINES). DO NOT SPLICE BUILDING PAPER HORIZONTALLY SO THAT THE PAPER WILL LAP OVER THE JAMB STRIPS. INSTALL SUCCESSIVE LINES OF BUILDING PAPER (B,C,D, ETC.) OVER JAMB AND HEAD FLASHING, LAPPING EA. COURSE.

ROOFING PER PLAN INSTALL PER MFG.'S SPEC.'S

ADDITIONAL LAYER OF FELT OVER FLASHING ROOFING FELT UNDER FLASHING

SEAL :

P LA 6"

SEE FOOTING SCHEDULE FOR FOOTING SIZE

DECK LEDGER DETAIL 1/4" = 1'-0"

NOTES-FLASHING 1/4" = 1'-0"

ROOF VENT DETAIL 1/4" = 1'-0"

D R A W I N G

N O :

S1.6

LOT 53, Dutch Fields Midway, UT 84049


Project Number NT SJP 1/4" = 1'-0"

D R A W I N G S FOR :

WIRE GAUGE, SPACING AND ATTACHMENT SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF SPECIFICATIONS.

NICHOLS RESIDENCE

NO
DOOR
BEARING FOR DOOR OR WINDOW HEADER
Strap per code if top plate is not continuous over header For information on lateral load capacities, refer to current Truss Joist rim board literature.

DATE

ISSUE

WEB STIFFENER ATTACHMENT


Gap: 1/8 " minimum 2 3/4 " maximum Three 8d (2 1/2 ") box nails, clinched (Three 16d ( 3 1/2 ") box nails at 3 1/2 " TJI joist flange widths) 1 1/2 " W Web stiffener each side. See sizes below. Tight fit W 1 1/2 " 1 3/4 " 2 5/16 " 3 1/2 " WEB STIFFENER SIZE
1/2 " 5/ " 8

THRESHOLD

MAIN FLOOR
VERIFY HDR. 8" MIN.
(2) #4 CONT. BAR

1 1/2 "

44" MAX. OR PROVIDE A FIXED LADDER FOR EGRESS

VERIFY WINDOW SIZE W/ FLOOR PLAN

Truss Joist rim Must have 1 3/4" minimum joist board

8" MAX

WATER CONNECTORS TYPE 'B' VENT TO EXTERIOR PER PLAN WATER HEATER STORAGE TANK (PER ENERGY COMPLIANCE SUMMARY).

bearing at ends

x2 x2

5/16 " 5/ " 16

minimum minimum

1" x 2 2x4

5/ " 16

minimum

36" MIN. FOR EGRESS 9 sq. ft. (BEDROOMS) 24" MIN. (FAMILY, ETC.)

ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF THE SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PRESIDENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

Web stiffeners required each side

8" diameter maximum hole for 11 " - 20" joists; 6" diameter maximum for 91/2 " joists or for blocking panels less than 12" D long. o not cut flanges .
7/ 8

INTERMEDIATE BEARING Blocking panels or shear blocking may be specified for joist stability at intermediate supports

THRESHHOLD DETAIL 1/4" = 1'-0"

E NG INEER:

TJI

rim joist

Truss Joist rim board closure

Must have 1 34" minimum joist / bearing at ends

Beveled bearing plate required when slope exceeds 1/4 " per foot

44" MAX EGRESS

Web stiffeners required each side

Twist strap and backer block required with slopes greater than 3" per foot

LOAD BEARING OR SHEAR WALL ABOVE (MUST STACK OVER WALL BELOW) 2x4 MIN. SQUASH BLOCKS GRAVEL BACKFILL W/ VAPOR BARRIER

STRAPS TO BE LOCATED BETWEEN 6" & 12" FROM TOP & BOTTOM OF WATER HEATER.

Park Engineering
90 South 200 West Suite #1 Heber City, Utah 84032 Tel. 435.654.1456 www.parkeng.net
2010 PARK ENGINEERING The designs and concepts shown are the sole property of Park Engineering. Not to be copied or reproduced without written permission.

BASEMENT

16 ga. 1" WIDE MINIMUM STEEL STRAP.

JOIST DETAILS 1/4" = 1'-0" 7


PROVIDE WEB STIFFENERS EA. SIDE

1/4" x 3" LAG SCREW W/ WASHERS AT EA. STRAP END TO WALL STUD.

WINDOW WELL DETAIL 1/4" = 1'-0"

" 18

PROVIDE 1" MAXIMUM SPACE BETWEEN WATER HEATER & WALL OR BLOCKING.

4
ROOF TRUSSES PER FRAMING PLANS ASPHALT SHINGLES OVER 30# FELT & 5/8" OSB SHEATHING

INTERIOR BEARING TO FLOOR DETAIL 1/4" = 1'-0"

18" HIGH PLYWOOD PLATFORM (FOR IGNITION SOURCES IN GARAGES ONLY).

PRE-ENGINEERED ROOF TRUSSES ROOF SHEATHING

BLOCKING: NAIL CONTINUOUS TO SHEATHING THRU SHEATHING TO TRANSFER SHEAR w/ A35 CLIP EA. BLOCK. PROVIDE VENTILATION THRU BLOCKING

NAIL THROUGH SHEATHING INTO BLOCKING TO PROVIDE SHEAR TRANSFER FULL HEIGHT BLOCKING

DRIP EDGE 4 MIL VAPOR RETARDER ON INTERIOR SIDE OF INSULATION H-1 CLIP EA. TRUSS

NAILED PORTION
SIMPSON A35 WALL SHEATHING

ALUM. SOFFIT & FASCIA

SIMPSON H-1 CLIP EA. TRUSS DOUBLE TOP PLATE

DOUBLE TOP PLATE

2x STUD WALL

~2'-0"

SIDING OVER TYVEK OR EQUAL VAPOR BARRIER & OSB SHEATHING

2x6 DF#2 STUDS @ 16" O.C. w/ R-19 INSUL. w/ 4 MIL VAPOR RETARDER ON INTERIOR SIDE

AN AR SP CLE 17" IMUM MAX

TRUSS TO WALL DETAIL 8 1/4" = 1'-0"

(2) 1/2" THRU-BOLTS 1/4" STEEL KNIFE PLATE. HEIGHT TO EQUAL COLUMN WIDTH

12"x12" COLUMN

STONE OR CONC. CAP (2) 1/2" x 7" 'J' BOLTS WELDED TO PLATE & EMBEDDED IN CONC.

3/4" T&G WFR. BRD. FLOOR SHEATHING LSL RIM BOARD TREATED SILL PLATE

~5'-0"

30" MIN. REBAR LENGTH

ONE #4 REBAR IN SHEAR CONE


1 " 2

12"x12" SQUARE PIER #3 @ 8" O.C. W/ (3) WITHIN 6" OF TOP & BOTTOM OF PIER

D R A W I N G

T I T L E :

STONE VENEER

FINISHED GRADE FLOOR JOISTS PER FRAMING PLANS

MIN. FROM CORNER

12" MIN. REBAR LENGTH

4'-0" MIN

DETAILS

36" MIN.

ANCHOR BOLTS PER FOUNDATION PLAN

1" AIR SPACE BEHIND BASEMENT FUR WALLS

PER PLAN

Simpson Strong-Tie STHD14RJ Rim Joist Installation


5 STRONG-TIE STHD14RJ 1/4" = 1'-0"

(8) 16d NAILS LAP TOP PLATE A MINIMUM OF 48" 1/4" GALVANIZED ANGLE W/ (2) 5/8" EXP. BOLTS EA. SIDE OF PIER (SIZE AS NEEDED) (4) #4 VERT BAR INTO FOOTING SIZE AS NECESSARY FOR ASTHETICS 1 _ 1 " 2 MIN.

P R O J E C T D R A W N

# :

B Y : B Y :

C H E C K E D SCALE :

NOTE: IF THIS DRAWING IS NOT 36" x 24", IT HAS BEEN REVISED FROM ITS ORIGINAL SIZE. SCALE IS NO LONGER APPLICABLE.

CONC. FOUNDATION WALL


UNDISTURBED NATURAL EARTH OR COMPACTED FILL TO 95% MAX DRY DENSITY 16" MIN. PER PLAN ~4'-0" BLOCKING

SEAL :

1 1 _ _ 1 " - 1 " 4 2

END TOP PLATE ON STUD

ALL LUMBER IN CONTACT w/ CONCRETE TO BE TREATED 4" SLAB ON GRADE OVER 4" GRAVEL FILL & 6 MIL VAPOR RETARDER CONTINUOUS FOOTING
2x STUD WALL GRAB RAIL METAL BRACKET STUDS @ 16" O.C.

D R A W I N G

N O :

WALL SECTION 1/2" = 1'-0"

GRAB RAIL DETAIL 1/4" = 1'-0"

TOP PLATE SPLICE DETAIL 1/4" = 1'-0"

11

STONE COLUMN DETAIL 1/4" = 1'-0"

S1.7

LOT 53, Dutch Fields Midway, UT 84049


Project Number NT SJP As indicated

D R A W I N G S FOR :

10

WATER HEATER STRAPPING 1/4" = 1'-0"

NICHOLS RESIDENCE