Você está na página 1de 2

RADIO FREQUENCY SYSTEMS

T h e C l e a r C h o i c e

RFS Plenum-Rated Cables


RFS ClearFillLine plenum-rated wideband cable with outstanding electrical performance supports all wireless in-building applications

ICA12-50JPL - 1/2 Diameter - Wideband - UV & CATVP Rated


Supporting Technologies
LMR (Land Mobile Radio): 450-512MHz Public Safety: 764-776MHz, 806-824/851-869MHz, 4400-5000MHz 700MHz LTE: 698-896 MHz Cellular: 824-896MHz Paging: 929-932MHz PCS/AWS (Advanced Wireless Services): 1710-2155MHz WiFi (Wireless Fidelity): 2300-2500MHz WiMax (Worldwide Interoperability for Microwave Access): 5100-5900MHz WMTS (Wireless Medical Telemetry): 608-614MHz, 1395-1400MHz, 1429-1432MHz

In-Building Cable Solutions


RFS delivers a cost-effective, in-building solution with its plenum-rated air-dielectric coaxial cable, the backbone of the ClearFill Line of products. CATVP-rated, with low flamespread and low-smoke characteristics, it is ideal for use within the building plenum defined as the "environmental air handling space." This permits use of the cable as part of an in-building Distributed Antenna System (DAS). Plenum-rated cables, tested in accordance with the National Fire Protection Agency (NFPA) testing method 262, have the most stringent flame-retardant and smoke-suppressant characteristics. Due to their low attenuation, outstanding heat transfer properties, and temperature-stabilized dielectric materials, RFS plenumrated cables provide a safe, long-term operating life at hightransmit power levels.

Exclusive Features
Supports Multiple RF Signals Complete Shielding The solid outer conductor of ClearFillLine coaxial cable creates a continuous RFI/EMI shield that minimizes system interference. Outstanding Intermodulation Performance RFS coaxial cable's solid inner and outer conductors virtually eliminate intermods. Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS factory. Wide Range of Applications Typical areas of application are: feedlines for plenum-space installations within occupied buildings or structures.

Outstanding electrical performance virtually eliminates intermods

WIRELESS | MOBILE RADIO | MICROWAVE | IN-TUNNEL | IN-BUILDING | TV & RADIO | HF & DEFENSE

RADIO FREQUENCY SYSTEMS


T h e C l e a r C h o i c e

RFS Plenum-Rated Cables


RFS ClearFillLine plenum-rated wideband cable with outstanding electrical performance supports all wireless in-building applications

Product Specifications
Size Jacket Maximum Return Loss, dB (VSWR) Impedance, Ohm Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW Inner Conductor dc Resistance, ohm/1000 m (ohm/1000 ft) Outer Conductor dc Resistance, ohm/1000 m (Ohm/1000 ft) RF Peak Voltage, Volts Jacket Spark, Volt RMS Capacitance, pF/m (pF/ft) Inductance, H/m (H/ft) Outer Conductor Material Inner Conductor Material Diameter over Jacket Nominal, mm (in) Diameter Outer Conductor, mm (in) Diameter Inner Conductor, mm (in) Minimum Bending Radius, Single Bend, mm (in) Minimum Bending Radius, Repeated Bends, mm (in) Cable Weight, kg/m (lb/ft) Tensile Strength, N (lb) Recommended / Maximum Clamp Spacing, m (ft) Installation Temperature, C(F) Storage Temperature, C (F) Operation Temperature, C(F) Flame Retardant Jacket Specifications 1/2" Plenum

Model Number ICA12-50JPL

18 (1.228:1) - in the specified bands 50 +/- 1 6 91 21.4 1.48 (0.45) 1.90 (0.58) 1500 8000 76 (23.2) 0.191 (0.058) Annularly Corrugated Copper Copper-Clad Aluminum Wire 15.93 (0.627) 13.8 (0.54) 4.8 (0.19) 120 (4.8) 254 (10) 0.4 (0.27) 1112 (250) 0.5 / 0.9 ( 1.8 / 3.0 ) -15 to +60 (+5 to +140) -15 to +85 (+5 to +185) -15 to +85 (+5 to +185) Meets/Exceeds Steiner Tunnel Test Method UL 910, NEC 820-53 (a) CATVP, NFPA-262.

Connectors
Model Number NF-LCF12-B32 NM-LCF12-B32 Cable Type, Size ICA/LCF/HCA/RHCA, 1/2 ICA/LCF/HCA/RHCA, 1/2 Description N Female N Male Sealing Code O-Ring O-Ring Conductor Attachment Inner Outer Basket Basket Spring Finger Spring Finger Trim Tool Series TRIM-Series-A TRIM-Series-A