Flare Gas Fatigue Vibration Acoustic

Ads by Google

Hot Posts
How to apply valve equation Depressuring ? High pressure and moderate/lo are common in oil and gas indu system with large vessels will l it significantly increases hazard and assets...

Friday, March 27, 2009

Acoustic Sound Solutions LogiSon.com/Acoustics Award Winning Sound Solutions to Improve Your Workplace Performance! Find Vibration Isolators www.KineticSystems.com Standard/Custom Vibration Isolation Products. Request A Quote Online! Ti Thermal Imaging Ltd www.thermalimaging.co.uk Leading IR Consultant Inspections/ Camera Sales/Rental-Global supplier Mobile Gas Flow Meter www.cs-instruments.com/ Flow and consumption measurement in gas and compressed air

FOLLOW ME

Enter your email address: Display problem ? Click HERE CLICK HERE to Subscibe FREE... An oil & gas processing and production facilities may consist of several level of pressure let down station. Typical examples are choke valve between christmas tree and flowline/production header, slugcatcher control valve, onshore pressure reduction station, steam control valve, desuperheating station, etc. Above valves are normally in continuous operation. Besides, there are other valves such as compressor surge / capacity control valve, overpressure dumping control valve, blowdown valve with restriction orifice, pressure relief valve, etc will experience large pressure drop and they are operated intermittently. There is pressure drop with mass passing through the valve, internal acoustic energy is generated and transmitted to downstream piping and potentially lead to severe piping excitation, vibration and stresses on downstream piping, in particular at discontinuity section i.e fabricated Tee, small bore connection, welded pipe and pipe support, etc. If the downstream piping system is not properly designed, effect of this acoustic excitation would lead to fatigue failure. Above acoustic excitation phenomena is also known as Acoustic Induced Vibration Fatigue. Generally high frequency (more than 1000Hz) acoustic energy contribute to AIV fatigue and once piping expose to AIV, piping can fail in very short period (possibly in several minutes to hours).

SUPPORT This Site

1 of 4

27/04/2011 14:30

http://webwormcpt.blogspot.com/2009/03/acoustic-induced-vibration-aiv-fatigue.html

Fluid Phase Generally Acoustic Induced Vibration (AIV) fatigue occur in gaseous system and normally AIV does not occur in liquid system. For two phase gas liquid flow system with high gas flow (i.e. more than 50% gas flow), AIV may starts to be problem and need to be investigated. As two phase flow is complicated in estimating the Acoustic energy, it is always conservative to consider 100% gas flow. Short & Long Term Operation AIV fatigue failure of piping downstream of piping is subject to operation time i.e. number of fatigue cycle. A piping in continuous (long term) operation, a design fatigue limit of 80MPa is normally used based on ASME fatigue design limits with suitable safety factors for long term sevice life. A fatigue limit of 185MPa (10^7 cycles) has been used for short-term operation based on published fatigue life data for carbon steel and stainless steel. This fatigue limit represents the maximum acceptable level of stress for 10^7 cycles (12-24 hours of operation) without any safety margin. Those pressure reduction devices has total accumulated service hour within the plant life less than 12 hours, one may consider AIV fatigue may not occur. Pressure relief valve is one of those devices potentially drop in this category. Experiences has shown that there is high frequency of operation of pressure relief device during plant black start-up and restart-up, AIV fatigue may occur in very short period (minutes to hours), PRV and other pressure reducing device may connect on same downstream pipe, etc, in many event AIV studies for PRV downstream piping to be conducted. Those PRV relief to ATM has very high potential drop in the short term category. Sound Power Level (PWL) Sound Power Level (PWL) is the acoustic energy generated by a pressure reduction device. There are several ways to assess the adequacy of the piping to resist AIV fatigue. One of the way to ensure piping downstream of pressure reducing device sufficiently storng to resist AIV fatigue is to ensure the PWL allowable limit of downstream piping higher than the PWL generated by the pressure reducing device. This will be disucssed in coming post.

Ads by Google
Pressure Vessel Pressure Relief ASME Pressure Gas Line Piping Gas Design
Recommended Jobs Chemical Engineer Cikarang - PT Priuk Perkasa Abadi Process Improvement Specialist Jakarta - EONCHEMICALS PUTRA, PT Process Engineer Jakarta - PT Bidar Timur Sales Engineer for Process Jakarta - PT. Yabestindo Mitra Utama Process Engineer (Code : PEG) South Jakarta - CITRA NUSANTARA GEMILANG

Piping Excitation When Expose to Acoustic Energy Sound Power Level (PWL) Prediction from AIV Aspect Several Criteria and Constraints for Flare Network - Piping Check Valve Types and Selection Potential Problem associate with Double NRV in Series within a Line Flow Element (FE) Upstream or Downstream of Control Valve (CV) ? Why a globe valve is located downstream of manual block valve on drain line ?

www.indeed.com

2 of 4

27/04/2011 14:30

http://webwormcpt.blogspot.com/2009/03/acoustic-induced-vibration-aiv-fatigue.html

Labels: AIV, Flare, Piping

Process engineer jobs

PROCESS ENGINEER
WESTINDO ESA PERKASA, PT - Cibinong
located at Cibinong, Bogor is looking for : PROCESS ENGINEER Requirements : S1 degree with background... Jobs Keywords: PROCESS ENGINEER Personal Notes... JobsDB Indonesia more jobs

Jobs by Indeed

posted by Webworm, 6:22 AM

Post a Comment
Let us know your opinion !!! You can use some HTML tags, such as <b>, <i>, <a>

Subscribe to Post Comments [Atom]

Create a Link

<< Home

3 of 4

27/04/2011 14:30

http://webwormcpt.blogspot.com/2009/03/acoustic-induced-vibration-aiv-fatigue.html

2008-2010 Chemical & Process Technology | Design by Webworm

4 of 4

27/04/2011 14:30

Você também pode gostar