SharingourGuidance WHYVARIABLEAIRVOLUME(VAV)?

WHYVARIABLEAIRVOLUME?
INTRODUCTION

Developersareshowingincreasinginterestincentral airconditioningformanyreasons,themostcommon ofwhichare: Challengesofverticalandhighdensityconstruction MoreeffectiveManagementcontrolofproperty Energyconscioussociety Rooftopcondensingunitfarms become maintenancenightmares

Useoftheinformationanddatacontainedwithintesengineering.comand/orthesepagesisatyoursolerisk. ForfullTermsofUseseewww.tesengineering.com/termsofuse.html 2008TESEngineering

VARIABLEAIRVOLUME
BOXCARVAV

Useoftheinformationanddatacontainedwithintesengineering.comand/orthesepagesisatyoursolerisk. ForfullTermsofUseseewww.tesengineering.com/termsofuse.html 2008TESEngineering

VARIABLEAIRVOLUME
WHYVAV?

Lowerinstalledsize Lessenergyused Greatercomfort Flexibility Longevity Serviceable

Useoftheinformationanddatacontainedwithintesengineering.comand/orthesepagesisatyoursolerisk. ForfullTermsofUseseewww.tesengineering.com/termsofuse.html 2008TESEngineering

VARIABLEAIRVOLUME
WHYVAV?

Lowerinstalledsize VAVsizeistypically16%lowerthanindividual Lessenergyused Smalleroverallsize X 15%savingsbyhavingfanspeedtrackwith varyingload Greatercomfort Easytoprovideseparatecomfortzonefor storefront(sun),generalsales(customers) andstockareas(employees) Dryersupplyairresultinginlowerindoor humidity Nooverpressurizationresultingindoors beingblownopen Constant,gentleairmotion Constant,automaticbalancingtoneed
Useoftheinformationanddatacontainedwithintesengineering.comand/orthesepagesisatyoursolerisk. ForfullTermsofUseseewww.tesengineering.com/termsofuse.html 2008TESEngineering

VARIABLEAIRVOLUME
WHYVAV?

Flexibility Easytoprovideseparatecomfortzone forstorefront(sun),generalsales (customers)andstockareas (employees) Easytoreconfigurewhenredemising

Serviceable Remotemonitoredmainunit Remotemonitoredtenantunits Unitcomponentsbuiltforaccessibility andreplaceability


Electricalcomponents Bearings Refrigerationsystems

Longevity 20+yearlifevs.1015forindividualunits Redundancy Multiple,independentairconditioning pipingcircuits Heavydutyconstruction Shaftsandbearingsaresignificantly heavier Doublewallairboxconstruction Heavierdutydampers,dampermotors, etc.

Useoftheinformationanddatacontainedwithintesengineering.comand/orthesepagesisatyoursolerisk. ForfullTermsofUseseewww.tesengineering.com/termsofuse.html 2008TESEngineering

VARIABLEAIRVOLUME
ISSUES/TOPICS

TenantLoad Supplementalunits Odorproducingtenants Supplyair Returnair Outsideair VAVTerminalBox Layout Controls Smokedetection InstallationRequirements Comfortcomplaints

Useoftheinformationanddatacontainedwithintesengineering.comand/orthesepagesisatyoursolerisk. ForfullTermsofUseseewww.tesengineering.com/termsofuse.html 2008TESEngineering

VARIABLEAIRVOLUME
ISSUES/TOPICS

TenantLoad Spacesensibleloaddetermines CFM Roofloadhandledattheunitlevel 50%+/ ofrecessedlightfixture loadisappliedtotheplenum& handledattheunitlevel Outsideairloadhandledatthe unitlevel PeopledensityperASHRAE Safetyfactorsunnecessarydueto VAVsystemloadshiftingcapability Doorsshallnotbeproppedopen

Supplementalunits Onlywhenthetenantsair conditioningand/orventilation requirementsexceedtheLandlords allocation Formostfoodpreparationareas Wheretenantsuseresultsina peopledensityhigherthantypically expectedinaretailspace,tenantmay berequiredtoprovidesupplemental coolingand/orventilationsystem

Useoftheinformationanddatacontainedwithintesengineering.comand/orthesepagesisatyoursolerisk. ForfullTermsofUseseewww.tesengineering.com/termsofuse.html 2008TESEngineering

VARIABLEAIRVOLUME
ISSUES/TOPICS

Supplyair 55Fduringpeakcoolingseason Resetscheduleonmoderateload days 14 connectionsat approximately20 centersprovided bytheLandlord 2000CFMmaximumper connection Bottomofductis14 above finishedfloor

Returnair Plenum Demisingwalltransferopenings Sheetmetalsleeve(s)withexpanded metalinopeningarefurnishedby Landlord,installedbytenant Grillelocationsthroughoutthestore &sizedat600FPMmaximum Transferairductorsoffitacrossspace ifopenceiling Nonefromfoodpreparationareas

Useoftheinformationanddatacontainedwithintesengineering.comand/orthesepagesisatyoursolerisk. ForfullTermsofUseseewww.tesengineering.com/termsofuse.html 2008TESEngineering

VARIABLEAIRVOLUME
ISSUES/TOPICS

Outsideair Coderequirementsforstreetlevel retail Demandcontrolventilationatthe unit Tenantmaydeclarethemselvesa criticalzone(asdefinedby ASHRAE)andincludeaspaceCO2 sensor Makeupairforodorexhaustisnot availablefromtheLandlordsystem Freecoolingairsideeconomizer EconomizerreliefisinLandlord unit

VAVTerminalBox Fanpoweredwhenheatisprovided Series(SFPVAV)foraircirculation Shutoff(VAV)foronlysmallspacesor wherenoheatrequired Heat NoheatinLandlordunit Demandcontrolventilationto maximizesupplyairtemperature duringcoldperiods ElectricheatprovidedbyTenantin fanpoweredVAVbox

Useoftheinformationanddatacontainedwithintesengineering.comand/orthesepagesisatyoursolerisk. ForfullTermsofUseseewww.tesengineering.com/termsofuse.html 2008TESEngineering

VARIABLEAIRVOLUME
ISSUES/TOPICS

Layout Zonestorefrontasseparatezone whenpossible Windows/sundefinesaseparate zone Sensorlocation Notinthesun Notbehindfixtures Wirelessthermostatsavailablefor moreflexibleafterinstallation locating

Controls Allcomponentsbythesame manufacturerastheLandlordssystem ConnecttoLandlordssystem EmptyconduitfromLandlords systemtotenantspaceorjunctionbox intenantspacewithcableloop ConnectionbyLandlordcontractorat tenantsexpense Mayincludezonepanelfor monitoring/controlofmultipleVAV boxes

Smokedetection IMCcommonreturnairexceptionwithvav boxeslessthan2000CFM


Useoftheinformationanddatacontainedwithintesengineering.comand/orthesepagesisatyoursolerisk. ForfullTermsofUseseewww.tesengineering.com/termsofuse.html 2008TESEngineering

VARIABLEAIRVOLUME
ISSUES/TOPICS

InstallationRequirements Externalductinsulation Linernotasubstitute) DuctbetweenLandlordmainandbox Highpressureconstruction,sealclassA X 4diametersofrigidstraightductaheadofbox Noflexibleconnectioninthissectionofduct VAVBoxLocation Stockroomorothernonsaleslocation Accessibilityrequired Volumedampersforeachsupplyairoutlet

InstallationRequirements Accessible Airbalance Aftercontrolsareinstalledand connectedtoLandlordsystem Deficienciestobeaddressed immediately Priortoceilinginstallationwhen practical ReportissuedtoLandlordbefore grandopening

Useoftheinformationanddatacontainedwithintesengineering.comand/orthesepagesisatyoursolerisk. ForfullTermsofUseseewww.tesengineering.com/termsofuse.html 2008TESEngineering

VARIABLEAIRVOLUME
ISSUES/TOPICS
InstallationDetail

Useoftheinformationanddatacontainedwithintesengineering.comand/orthesepagesisatyoursolerisk. ForfullTermsofUseseewww.tesengineering.com/termsofuse.html 2008TESEngineering

VARIABLEAIRVOLUME
ISSUES/TOPICS

Comfortcomplaints ContactLandlord Providedate,timeofday, temperature,humidity,noise,lack ofairflow,etc. Landlordwillverify Supplyairtemperature Spacetemperature VAVboxoperation dowewantthis??

Useoftheinformationanddatacontainedwithintesengineering.comand/orthesepagesisatyoursolerisk. ForfullTermsofUseseewww.tesengineering.com/termsofuse.html 2008TESEngineering

VARIABLEAIRVOLUME
TENANTBENEFITS/FLEXIBILITY

VAVboxesallowmorezoningforstorefront(sun),generalsales(customers)andstockareas (employees)withsignificantlylessthanthecostofseparatetraditionalrooftopunits. Landlordssystemprovidesredundancy. Landlordsbuiltinredundancyeliminatestheneed forTenantstopurchasebackupunitstoprovideredundancy. Landlordtoinstallhigherenergyefficientunitsleadingtolowerlongtermenergyuse. X EnablesLandlordtoachieveLEEDcertificationandgivetheTenantbenefitofLEEDpointsif TenantseeksLEEDcertification. NoRTUroofpenetrationsbyTenant. FewerroofpenetrationsforLandlordscentralized coolingsystemleadstofewerleaks. Lowercommonareacostsduetoreducedsecurityrelatedandfutureroofingrelatedissues.

Useoftheinformationanddatacontainedwithintesengineering.comand/orthesepagesisatyoursolerisk. ForfullTermsofUseseewww.tesengineering.com/termsofuse.html 2008TESEngineering

VARIABLEAIRVOLUME
TENANTBENEFITS/FLEXIBILITY

NoRTUmaintenanceresponsibilityforTenantsasLandlordwillprovidepreventative maintenanceaswellasmaintenancecontractforroutinerepairsofLandlordsrooftop boxcarunits. TenantsonlyhavemaintenanceresponsibilityfortheirinspaceVAVboxesanddistribution. Neatersitewithlessclutteredsplitunitsandreducedopportunitiesforvandalism. X LandlordVACsystemwillbemonitoredandcontrolledviaacomputerizedEnergy ManagementSystem. Landlordhastheabilitytotroubleshoottenantairconditioning complaints/problems remotely Greatercomfort
Dryersupplyairresultinginlowerindoorhumidity Nooverpressurizationresultingindoorsbeingblownopen Constant,gentleairmotion Constant,automaticbalancing

Useoftheinformationanddatacontainedwithintesengineering.comand/orthesepagesisatyoursolerisk. ForfullTermsofUseseewww.tesengineering.com/termsofuse.html 2008TESEngineering

VARIABLEAIRVOLUME
LANDLORDSHVACCHARGE

$2.50to$4.00/ft/year ExampleofTenantscostofowningandoperatingstandalonerooftopunit About$3.10/ft/year


Installation($1.30/ft/year 7yearterm)
Equipment Roofing Crane Startup

AnnualMaintenance($0.50/ft/year) Energy($1.30/ft/yearwith$0.10/kwhelectricity)

Useoftheinformationanddatacontainedwithintesengineering.comand/orthesepagesisatyoursolerisk. ForfullTermsofUseseewww.tesengineering.com/termsofuse.html 2008TESEngineering