Analog/ISDN/GeoCENTREX Reverse Charging at Setup Time (RCST)


A30828-X1150-B647-2-7629

Reverse Charging at Setup Time (RCST)

Information Analog/ISDN/GeoCENTREX

Trademarks: All designations used in this document can be trademarks, the use of which by third parties for their own purposes could violate the rights of their owners.

Copyright (C) Siemens AG 2000-2001


Issued by the Information and Communication Networks Group Hofmannstrae 51 D-81359 Mnchen Technical modifications possible. Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon in a written contract.

A30828-X1150-B647-2-7629

Information Analog/ISDN/GeoCENTREX

Reverse Charging at Setup Time (RCST)

This document consists of a total of 12 pages. All pages are issue 2.

Contents
1 2 3 3.1 3.2 3.3 3.3.1 3.3.2 3.4 4 5 6 Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Mode of operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Subscriber controlled input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Analog. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ISDN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GeoCENTREX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Analog. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ISDN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Legend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 8 8 9 9 9 9

Call charge registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Administration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

A30828-X1150-B647-2-7629

Reverse Charging at Setup Time (RCST)

Information Analog/ISDN/GeoCENTREX

A30828-X1150-B647-2-7629

Information Analog/ISDN/GeoCENTREX

Reverse Charging at Setup Time (RCST)

1 Denition
The feature Reverse Charging at Setup Time (RCST) allows a calling subscriber to set up a call for which the called subscriber is to accept the charges. A reverse charge call is introduced by a special access code. The called subscriber can agree to pay for the call or decline to accept it.

Network node Service access code and directory number RCST request Confirm reverse charging function key)

RCST accept

Operator benefits feature with additional marketing opportunities Subscriber benefits calling subscriber can request reverse charging without the help of an operator calling subscriber does not pay any call charges Availability Analog Subscriber GeoCENTREX subscriber Use and effect Calling Called subsubscriber scriber RCST use RCST effect Interactions For interaction with other features, see Feature Interactions. X X --X X X ISDN X X

A30828-X1150-B647-2-7629

Reverse Charging at Setup Time (RCST)

Information Analog/ISDN/GeoCENTREX

2 Mode of operation
In order to use the feature Reverse Charging at Setup Time (RCST) the calling subscriber first dials the feature access code or presses a function key. Then he or she dials the number of the desired subscriber. If the called subscriber is willing to accept the charges, the call is switched through and the calling ISDN subscriber sees appropriate confirmation on the terminal display field. An analog subscriber is not sent special confirmation: through-connection of the call confirms reverse charging. For the calling party the call is then free of charge. If the called party is not willing to accept the reverse charge call, or if the network node does not support reverse charging, the calling subscriber is informed via the display that the call has not been accepted. It is also possible for an announcement to be applied (for example: requested feature not accepted). If an analog subscriber declines to accept a reverse charge call, the call is likewise released. When the called subscriber has confirmed that he or she will accept the reverse charge call, the charges are recorded as if the called party had set up the call. With the feature AOC it is possible to have the charges shown on the terminal display. Capacity The percentages indicate the number of authorized subscribers for the feature within the network node and their simultaneous application. Analog Authorization Subscriber GeoCENTREX subscriber 20% 20% Use 100% 100% ISDN Authorization 20% 20% Use 100% 100%

A30828-X1150-B647-2-7629

Information Analog/ISDN/GeoCENTREX

Reverse Charging at Setup Time (RCST)

3 Subscriber controlled input


The feature can be administrated by subscriber controlled input. For the subscriber procedure, see: Analog subscriber ISDN subscriber GeoCENTREX Analog subscriber ISDN subscriber Subscriber controlled input functions Signaling method Analog Pulse Activate Deactivate Enter data Delete data Enter data and activate Delete data and deactivate Activate with/without data Feature use Interrogate state Interrogate data Interrogate state with/without data Access code The access code for subscriber controlled input consists of a maximum of 6 characters or, for GeoCENTREX subscribers, a maximum of 5 characters. It can be formed from the symbols 5 , # and the service code (SC) with the digits 0 to 9. The operator can specify the character strings for the access code. Differences for pulse dialing The selected digits are not obligatory; other digits can be input (depending on the existing numbering plan). 1111 at the beginning of an input in place of 5 1112 at the beginning of an input in place of # 1113 at the beginning of an input in place of 5 # 5 as a disconnecting signal after the service code, not relevant # after the subscriber controlled input, not relevant ----------------------DTMF --------------X ------ISDN Keypad --------------X ------Funct. --------------X -------

A30828-X1150-B647-2-7629

Reverse Charging at Setup Time (RCST)

Information Analog/ISDN/GeoCENTREX

Acknowledgments after subscriber controlled input The following tones, announcements and display texts are examples and can be administrated by the operator. The display texts can be changed to suit individual projects. The subscriber controlled input can be acknowledged by: Tones ringing tone acceptance tone subscriber busy tone or number unobtainable tone (NU) Announcements subscriber controlled input successful subscriber controlled input unsuccessful feature is already activated feature is not activated feature is not available wrong input Display texts (only in ISDN) wrong input not authorized request rejected successful unsuccessful not available In the event of a successful call setup with reverse charging, the following display is possible: REVERSE CHARGE CALL

3.1

Analog
Feature use Start Directory number Connection DT SC DN A-B

3.2

ISDN
Feature use Start Directory number Connection DT SC DN A-B

A30828-X1150-B647-2-7629

Information Analog/ISDN/GeoCENTREX

Reverse Charging at Setup Time (RCST)

3.3
3.3.1

GeoCENTREX
Analog
For inputs, see subscriber procedure Analog.

3.3.2

ISDN
For inputs, see subscriber procedure ISDN.

3.4

Legend
Introduces activation from terminal or introduces input from terminal or used as separator Introduces deactivation from terminal or introduces cancellation from terminal or used at end of feature input Enter ... Lift handset () A-B DN DT SC Optional input Connection between calling subscriber (A) and called subscriber (B) Directory number Dial tone Service code

4 Call charge registration


A reverse charge call is charged using the directory number of the calling subscriber according to the tariff (zone) of the called network node. (Reverse charging is only possible if the calling subscribers zone is administrated in the called network node. Particular attention must be paid to the own network node.) Charge metering at the called subscribers end starts when the call begins. The calling subscriber is given the status no charge. The following data record types are supported in the case of reverse charging: AMA DEB pulse metering

A30828-X1150-B647-2-7629

Reverse Charging at Setup Time (RCST)

Information Analog/ISDN/GeoCENTREX

Call charge registration is possible with: Automatic Message Accounting with Individual Call Charge Registration Pulse Metering Message Detail Recording (MDR) for GeoCENTREX Flat rate Automatic Message Accounting with Individual Call Charge Registration (AMA) and pulse metering can be combined. One or more call charge pulses can be generated for pulse metering. Charges for feature input and feature usage The charges for operator inputs, successful subscriber controlled input and feature usage are assigned to the subscriber. The following call charge registration is possible: Facility input by operator (FAIO) Facility input by subscriber (FAIS) Facility usage (FAU) Action Activate Deactivate Enter data Delete data Assign authorization Remove authorization Assign authorization to modify Remove authorization to modify Request state, data Use Call charges for connections Call charges for connections are assigned as follows: The called subscriber pays the call charges after conrmation of reverse charging. FAIO --------X X --------FAIS --------------------FAU ------------------X

5 Administration
The operator can perform all administration functions on the NetManager by means of user-friendly applications or MML commands. Feature authorization The network operator assigns authorization for the feature when requested by the subscriber. Subscriber access types The feature can be used with the following types of subscriber access:

10

A30828-X1150-B647-2-7629

Information Analog/ISDN/GeoCENTREX

Reverse Charging at Setup Time (RCST)

Type

Subscriber Analog ISDN --X --X ------X ---------

GeoCENTREX Analog X --X ------------------ISDN --X --X -----------------

Main station Basic access PBX PBX with BA and/or PA PBX line PBX line with Direct Dialing In (DDI) PBX line, connected like a subscriber Coinbox Emergency call station MLHG line Basic attendant console MAC attendant console Call charge registration

X --X --------X ---------

For more information, please refer to OMN:EXCH-TA. System administration The following feature data can be administrated in the network node: options for subscriber controlled input creation of announcements recording by means of trafc measurement For more information, please refer to OMN:EXCH-SY. Subscriber administration For more information, please refer to OMN:EXCH-SU. GeoCENTREX administration For more information, please refer to OMN:EXCH-CTX.

A30828-X1150-B647-2-7629

11

Reverse Charging at Setup Time (RCST)

Information Analog/ISDN/GeoCENTREX

6 Requirements
Hardware UI-LTG with OCANEQ speech equipment and INDAS for: indication of rejected connection Signaling Signaling between the network nodes Signaling system no. 7 (SS7) ISDN user part (ISUP) Telephony user part (TUP) Subscriber signaling Analog Dual-tone multifrequency (DTMF) Pulse dialing ISDN Digital subscriber signaling system no.1 (DSS1) Subscriber interfaces The following interfaces for subscriber access can be used: DLU LTG V5.1 interface V5.2 interface

12

A30828-X1150-B647-2-7629