PROFINET I-Device for connecting the CPU as an intelligent PROFINET device under a SIMATIC or non-Siemens PROFINET IO controller PROFINET interface with integrated 3-port switch Isochronous mode on PROFINET With many communication options: PG/OP communication, PROFINET IO, PROFINET CBA, open IE communication (TCP, ISO-on-TCP and UDP), web server and S7-communication (with loadable FBs) Fast, simple and end-to-end programming of a system with modular programs via STEP 7 Compact SIMATIC Micro Memory Card (MMC) Optional PROFIBUS master for 32 PROFIBUS DP slaves (with master interface 6ES7138-4HA00-0AB0) Fail-safe IM 151-8F PN/DP CPU PROFIsafe available Interface module for SIMATIC ET 200S with integrated CPU S7-314 For high-performance control solutions in ET 200S Increase of the availability of systems and machines PROFINET IO controller for up to 128 IO devices Note: SIMATIC Micro Memory Card required for operation of CPU.
I Technical specifications
6ES7 151-8AB00-0AB0 Product version Associated programming package Supply voltages Rated value permissible range, lower limit (DC) STEP7 V5.4 SP4 or higher 6ES7 151-8AB01-0AB0 STEP7 V 5.5 or higher
20.4 V 24 V DC/16 A miniature circuit breaker with type B and C tripping characteristics. Note: The 24 V DC/16 A miniature circuit breaker with type B tripping characteristics trips before the device protection fuse. The 24 V DC/16 A miniature circuit breaker with type C tripping characteristics trips 5 ms 1.8 A; typ. 0.21 As 700 mA 380 mA; 460 mA with DP master module 5.5 W
20.4 V 24 V DC/16 A miniature circuit breaker with type B and C tripping characteristics. Note: A 24 V DC/16 A miniature circuit breaker with type B tripping characteristics trips before and with type C tripping characteristic after the device protection fuse.
Mains buffering Mains/voltage failure stored energy time Current consumption Inrush current, max. It Current output to backplane bus (5 V DC), max. from supply voltage 1L+, max. Power losses Power loss, typ. Memory Work memory integrated expandable size of retentive memory for retentive data blocks Load memory pluggable (MMC) pluggable (MMC), max.
5 ms 1.8 A; typ. 0.13 As 700 mA 352 mA; 426 mA with DP master module 5.5 W
Yes 8 Mbyte
Yes 8 Mbyte
9/14
Siemens ST 70 2011
Siemens AG 2011
DB Number, max. Size, max. FB Number, max. Size, max. FC Number, max. Size, max. OB Size, max. Nesting depth per priority class additional within an error OB CPU processing times for bit operations, min. for word operations, min. for fixed point arithmetic, min. for floating point arithmetic, min. Counters, timers and their retentivity S7 counter Number Retentivity - adjusted - lower limit - upper limit - preset Counting range - adjusted - lower limit - upper limit IEC counter Type Number S7 times Number Retentivity - adjusted - lower limit - upper limit - preset Time range - lower limit - upper limit IEC timer Type Number
256 Yes 0 255 Z 0 to Z 7 Yes 0 999 SFB Unlimited (limited only by RAM capacity) 256 Yes 0 255 No retentivity 10 ms 9 990 s SFB Unlimited (limited only by RAM capacity)
256 Yes 0 255 Z 0 to Z 7 Yes 0 999 SFB Unlimited (limited only by RAM capacity) 256 Yes 0 255 No retentivity 10 ms 9 990 s SFB Unlimited (limited only by RAM capacity)
Siemens ST 70 2011
9/15
Siemens AG 2011
256 byte Yes MB 0 to MB 15 8; 1 memory byte 511; Number range: 1 to 511 64 Kibyte Yes; via non-retain property on DB Yes 510 byte; per priority class
256 byte Yes MB 0 to MB 15 8; 1 memory byte 1 024; Number range: 1 to 16,000 64 Kibyte Yes; via non-retain property on DB Yes 32 768 byte; 2048 byte max. per block
2 048 byte 2 048 byte 2 048 byte 2 048 byte 2 048 byte 2 048 byte 128 byte 128 byte None
2 048 byte 2 048 byte 2 048 byte 2 048 byte 2 048 byte 2 048 byte 128 byte 128 byte 1; With PROFINET IO, the length of the user data is limited to 1600 byte 16 336 16 336 496 496 1 021 1 021 124 124 1 Station width: <= 1 m or < 2 m 63; Centralized
16 336 16 336 496 496 1 021 1 021 124 124 1 Station width: <= 1 m or < 2 m 63; Centralized
Yes Yes 6 wk; At 40 C ambient temperature, typically Clock continues to run with the time at which the power failure occurred 10 s
Yes Yes 6 wk; At 40 C ambient temperature, typically Clock continues running after POWER OFF Clock continues to run with the time at which the power failure occurred 10 s; Typ.: 2 s
9/16
Siemens ST 70 2011
Siemens AG 2011
Yes Inputs, outputs, memory bits, DB, times, counters 30 30 14 Yes Yes Yes 2 Yes 500 No 100; only the last 100 entries are retained
Yes Inputs, outputs, memory bits, DB, times, counters 30 30 14 Yes Yes; up to 2 simultaneously Yes 4 Yes 500 No 100; only the last 100 entries are retained Yes Yes Yes; with DP master module Yes; with DP master module No Yes; I blocks 76 byte 76 byte
Siemens ST 70 2011
9/17
Siemens AG 2011
Yes; via integrated PROFINET interface and loadable FBs 8 1 460 byte 8 192 byte
Yes; via integrated PROFINET interface and loadable FBs 8 8 192 byte Yes; via integrated PROFINET interface and loadable FBs 8 1 472 byte 12 11 1 1 11 1 1 10 0 0 10; with loadable FBs 10 32 4; with DP master module
9/18
Siemens ST 70 2011
Siemens AG 2011
1 ms 200 200 2 000 byte 2 000 byte 250 byte 3; 2x PN OPC/1x iMap 500 ms 200 2 000 byte Yes 16 240 byte; slave-dependent PROFINET Ethernet Yes Yes 3; RJ45 Yes Yes Yes
1 ms 200 200 2 000 byte 2 000 byte 450 byte 3; 2x PN OPC/1x iMap 500 ms 200 2 000 byte Yes 16 240 byte; slave-dependent PROFINET Ethernet Yes Yes 3; RJ45 Yes Yes Yes Yes 200 ms; PROFINET MRP 50 Yes
Siemens ST 70 2011
9/19
Siemens AG 2011
Yes Yes; with DP master module Yes; with loadable FBs No Yes; Via TCP/IP, ISO on TCP, and UDP 100 Mbit/s; full duplex 128 128 128 128 61
Yes Yes; with DP master module Yes; with loadable FBs Yes; OB 61; only for PROFINET IO Yes; Via TCP/IP, ISO on TCP, and UDP 100 Mbit/s; full duplex 128 128 128 128 61 64 64 Yes Yes Yes 32 Yes 8 Yes 8 Yes 250 Ps, 500 Ps,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option) Minimum value depends on communication share set for PROFINET I/O, on the number of I/O devices, and on the number of configured user data units. 250 s to 512 ms (depends on operating mode; for more details, refer to Operating Instructions, "Interface Module IM151-8 PN/DP CPU") 2 kbyte 2 kbyte 1 024 byte; with PROFINET I/O
Yes Yes 32 Yes 8 Yes 8 Yes Adjustable: 250 s, 500 s and 1 ms Minimum value depends on communication share set for PROFINET I/O, on the number of I/O devices, and on the number of configured user data units. 250 s - 128 ms (at signal cycle 250 s); 500s - 256 ms (at signal cycle 500 s); 1 ms - 512 ms (at signal cycle 1 ms) 2 kbyte 2 kbyte 254 byte; with PROFINET I/O
Updating times Address area - Inputs, max. - Outputs, max. User data per address area, max. - User data consistency, max. PROFINET IO device Services - PG/OP communication - Routing - S7 communication - Isochronous mode - Open IE communication - IRT, supported
Yes Yes Yes; With loadable FBs No Yes; Via TCP/IP, ISO on TCP, UDP Yes
9/20
Siemens ST 70 2011
Siemens AG 2011
Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device Yes 2
1 440 byte; Per IO controller with shared device 1 440 byte; Per IO controller with shared device 64 1 024 byte Yes Yes Yes; Via TCP/IP, ISO on TCP, and UDP 8 0, 20, 21, 23, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 External interface via master module 6ES7138-4HA00-0AB0 RS 485 Yes No No Yes No No No No No No
2nd interface Type of interface Physics Isolated Power supply to interface (15 to 30 V DC), max. Functionality MPI DP master DP slave PROFINET IO controller PROFINET IO device PROFINET CBA Open IE communication Web server Local Operating Network DP master Number of connections, max. Services - PG/OP communication - Routing - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server - Equidistance mode support - Isochronous mode - SYNC/FREEZE - Activation/deactivation of DP slaves - Number of DP slaves that can be simultaneously activated/deactivated, max. - Direct data exchange (slave-to-slave communication) - DPV1
Siemens ST 70 2011
9/21
Siemens AG 2011
Yes; V5.4 SP4 Yes Yes Yes Yes; optional Yes; optional Yes; optional Yes; optional See instruction list 8 Yes See instruction list See instruction list
Yes; V5.5 or higher Yes Yes Yes Yes; optional Yes; optional Yes; optional Yes; optional See instruction list 8 Yes Yes; With S7 block Privacy See instruction list See instruction list
Yes Yes Yes Yes Yes Yes Yes Yes Yes 500 V DC Yes Yes
Yes Yes Yes Yes Yes Yes Yes Yes Yes 500 V DC
Yes
75 V DC / 60 V AC
75 V DC / 60 V AC
120 mm; DP master module: 35 mm 119.5 mm 75 mm 320 g; DP master module: Approx. 100 g
120 mm; DP master module: 35 mm 119.5 mm 75 mm 320 g; DP master module: Approx. 100 g