Cooperation:

BHK-systeme GmbH & SOMMER energy

CHP Prodution &


Delivery

Profitability
calculation
Maintenance &
Plant consulting

Planning & Project

Remote monitoring

Commisioning

customers CHP
solution
General approval- &
application system

Installation &
Project
management
Financing

Technical training &


instruction

Reliable spare part


supply

Control concept

Sommer energy
-

Production of cogeneration units


Service of CHP-equipment
Consultation to the energy situation
Delivery and introduction of modules

Without mind or reason...

More than 66% energy with separated generation is necessary


to generate the same amount of electrical current and heat.

What is the difference between one:


power plant

cogeneration unit

efficiency:
41%

CHP cooling by water, too.


But: a thermal energy flows
in closed heating circuit.
efficiency :
90%

CHP - functionality
exhaust
gas
fuil
engine
generator
heat pipe
consumer

cooling water
heat consumer

electrical
consumer

Control Unit
switching device developed
and produced in our house
centrepiece is programmable
logic control
an alphanumerical display
with function keys shows
working conditions
Reference value can be
changed

Control Unit
CHP operation is
customisable on the
respective application profile
realizable are operating
methods like electric
capacity-, heat- and currentcontrol
emergency power mode can
be realised
optionally: data transmission,
remote monitoring and
protocol printing

Control Unit

Visualization

Product line gas units up to 190 kW natural gas


OEKO 50G

OEKO 70G

OEKO 100G

OEKO 140G

OEKO 160G

OEKO 190G

electrical (kW)

50

68

100

140

160

190

thermal (kW)

78

100

138

207

222

263

142

192

279

392

445

519

MAN
E 0836
E 312

MAN
E 0836
LE 302

MAN
E 3608
LE 202

MAN
E 2876
E 312

MAN
E 2876
LE 302

MAN
E 0876
E 302

4R

6R

6R

6R

6R

6R

4580cm

6870cm

6870cm

12820cm

12820cm

12820cm

generator (%) cos phi = 1

93,2

94,2

95,0

95,0

95,0

95 ,7

electrical (%)

35,7

36,7

39,0

36,9

36,0

39,0

thermal (%)

52,6

53,3

49,1

52,8

49,9

48,9

allover (%)

88,3

90,0

88,1

89,7

85,9

87,9

outlet max (C)

88

88

88

88

88

88

inlet max (C)

70

70

70

70

70

70

410

610

450

590

510

510

2,1x1,2x1,8

2,3x1,2x1,8

2,4x1,2x1,9

3,0x1,3x1,8

3,5x1,5x2,0

3,5x1,5x1,8

continuos output

energy input (kW)

engine typ

number of cylinders
cylinder capacity

efficiency

temperatures

exhaust gas (C)

dimensions
LxBxH (m)

Product line gas units up to 900 kW natural gas


OEKO 250G

OEKO 350G

OEKO 400G

OEKO 500G

OEKO 800G

OEKO 900G

electrical (kW)

250

350

400

500

800

956

thermal (kW)

321

498

538

592

852

1277

energy input (kW)

668

934

1045

1226

2098

2456

MAN
E 2848
LE 322

MAN
E 2842
LE322

MAN
E 2842
LE322

LIEBHERR
G 9512

GUASCOR
SFGLD 480

GUASCOR
SFGLD 560

8V

12 R

12 V

12 V

16 V

16 V

14620cm

21930cm

21930 cm

25000cm

47900cm

56300cm

generator (%) cos phi = 1

95,3

96,3

96,3

94,6

96,5

96,5

electrical (%)

39,0

39,0

38,3

44,1

38,1

38,9

thermal (%)

47,3

45,5

51,4

48,3

40,6

52,0

allover (%)

86,3

84,5

89,7

92,4

78,7

90,9

outlet max (C)

88

88

88

88

90

90

inlet max (C)

70

70

70

70

70

70

690

690

440

620

498

440

3,7x1,6x2,0

4,0x1,6x2,1

4,0x1,6x2,1

4,0x1,6x2,0

4,8x2,0x2,8

5,5x2,0x2,8

continuos output

engine typ

number of cylinders
cylinder capacity

efficiency

temperatures

exhaust gas (C)

dimensions
LxBxH (m)

Product line gas units up to 170 kW biogas


OEKO 45BG

OEKO 60BG

OEKO 80BG

OEKO 100BG

OEKO 115BG

OEKO 170BG

electrical (kW)

45

58

80

100

115

170

thermal (kW)

72

82

107

127

174

207

144

168

217

270

335

450

MAN
E 0834
LE302

MAN
E 0836
E 312

MAN
E 0836
LE 202

MAN
E 0836
LE 202

MAN
E 2876
TE302

MAN
E 2876
LE302

4R

6R

6R

6R

6R

6R

4580cm

6870cm

6870cm

6870cm

12820 cm

12820 cm

generator (%) cos phi = 1

92,7

93,2

95,0

95,0

95,0

95,7

electrical (%)

33,3

35,7

36,9

37,0

34,3

37,8

thermal (%)

53,3

48,8

49,3

47,0

51,9

46,0

allover (%)

86,6

84,5

86,2

84,0

86,2

83,8

outlet max (C)

85

85

85

85

85

85

inlet max (C)

70

70

70

70

70

70

180

180

180

180

180

180

1,8x1,0x1,7

1,8x1,0x1,7

2,2x1,0x1,7

2,2x1,0x1,7

3,2x1,1x1,7

3,3x1,1x1,7

continuos output

energy input (kW)

engine typ

number of cylinders
cylinder capacity

efficiency

temperatures

exhaust gas (C)

dimensions
LxBxH (m)

Product line gas units up to 370 kW biogas


OEKO 190BG

OEKO 240BG

OEKO 255BG

OEKO 310BG

OEKO 350BG

OEKO 370BG

electrical (kW)

190

240

255

310

350

370

thermal (kW)

227

306

304

410

432

433

energy input (kW)

490

620

657

853

922

946

MAN
E 2876
LE 302

MAN
E 2848
LE 322

MAN
E 2848
LE 322

MAN
E 2842
LE 322

MAN
E 2842
LE 322

MAN
E 2842
LE 322

6R

8V

8V

12 V

12 V

12 V

12820 cm

14620 cm

14620 cm

21930 cm

21930 cm

21930 cm

generator (%) cos phi = 1

95,7

95,3

95,3

96,3

96,3

96,3

electrical (%)

38,8

38,7

38,8

36,3

37,9

39,1

thermal (%)

46,3

49,4

46,3

48,1

46,8

45,8

allover (%)

85,1

88,1

85,1

84,4

84,7

84,9

outlet max (C)

85

85

85

85

85

85

inlet max (C)

70

70

70

70

70

70

180

180

180

180

180

180

3,3x1,1x1,7

3,5x1,4x1,7

3,5x1,4x1,7

3,8x1,4x2,0

3,8x1,4x2,0

3,8x1,4x2,0

continuos output

engine typ

number of cylinders
cylinder capacity

efficiency

temperatures

exhaust gas (C)

dimensions

LxBxH (m)

Product line vegetable oil units vegetable oil


OEKO
8PS

OEKO
20PS

OEKO
35PS

OEKO
50PS

OEKO
100PS

OEKO
150PS

OEKO
200PS

OEKO
250PS

OEKO
400PS

OEKO
500PS

electrical (kW)

8,2

20

35

50

100

150

200

250

400

500

thermal (kW)

14

35

48

70

138

170

226

282

445

547

energy input (kW)

29

60

98

138

280

396

532

651

1031

1302

Kubota
D1703-E

Kubota
V3300

Mitsubishi
S6S

Mitsubishi
S6S-DT

MAN
D2866

Cummins
NTA855

Cummins
NTA855

Cummins
KT19

Cummins
VTA25

Cummins
KTA38

3R

4R

6R

6R

6R

6R

6R

4R

12 V

12 V

1670cm
3

3320cm3

4990cm3

4990cm3

11970cm

14000cm3

14000cm3

18900cm3

28000cm3

38000cm3

generator (%) cos


phi = 1

86,6

86,7

92,0

93,2

95,0

95,0

95,7

95,3

96,3

96,3

electrical (%)

28,3

33,3

35,7

34,8

35,7

37,8

37,6

38,4

38,8

38,4

thermal (%)

49,3

58,3

49,0

50,7

49,3

42,9

42,5

43,3

43,2

42,0

allover (%)

77,6

91,6

84,7

85,5

85,0

80,7

80,1

81,6

81,9

80,4

outlet max (C)

85

85

85

85

85

85

85

85

85

85

inlet max (C)

70

70

70

70

70

70

70

70

70

70

180

180

180

180

180

180

180

180

180

180

1,5x0,8
x1,3

1,7x0,7
x1,45

1,9x0,8
x1,5

1,9x0,8
x1,5

2,0x1,0
x1,6

3,2x1,2
x1,8

3,5x1,4
X1,9

3,8x1,6
x1,8

3,8x1,4
X1,9

4,5x1,6
x1,9

continuos output

engine typ

number of cylinders
cylinder capacity

efficiency

temperatures

exhaust gas (C)

dimensions
LxBxH (m)

Product line heating oil units heating oil


OEKO 8HS

OEKO 20HS

OEKO 35HS

OEKO 50HS

OEKO 60HS

OEKO 70 HS

OEKO 80HS

OEKO 100HS

OEKO 240HS

electrical (kW)

8,2

20

35

50

56

70

80

105

240

thermal (kW)

14

35

48

70

72

89

102

126

241

energy input (kW)

29

60

98

138

143

179

205

271

585

Kubota
D1703-E

Kubota
V3300

Mitsubishi
S6S

Mitsubishi
S6S-T

Deutz
BF4M 1013 E

Deutz
BF4M 1013E

Deutz
BF4M 1013E

Deutz
BF6M1013E

MAN
D 2876

3R

4R

6R

6R

4R

4R

4R

6R

6R

1670m

3320m

4990m

4990m

4760m

4760m

4760m

7140m

12820m

generator (%) cos phi = 1

86,6

86,7

92,0

93,2

93,2

94,1

94,1

95,0

95,3

electrical (%)

28,3

33,3

35,7

34,8

39,2

39,2

39,0

38,8

41,0

thermal (%)

48,3

58,3

49,0

50,7

50,3

49,8

49,8

46,5

41,2

allover (%)

76,6

91,6

84,7

85,5

89,5

89,0

88,8

85,3

82,2

outlet max (C)

85

85

85

85

85

85

85

85

85

inlet max (C)

70

70

70

70

70

70

70

70

70

180

180

180

180

180

180

180

180

180

1,5x0,8x1,
3

1,7x0,7x1,45

1,9x0,8x1,
5

1,9x0,8x1,
5

2,0x0,8x1,6
5

2,2x1,0x1,8

2,0x0,8x1,6
5

2,3x1,0x1,7

3,3x1,1x1,7

continuos output

engine typ
number of cylinders
cylinder capacity

efficiency

temperatures

exhaust gas (C)

dimensions
LxBxH (m)

Product line ethanol / methanol units ethanol / methanol


OEKO
100 ME

OEKO
150 ME

OEKO
200 ME

OEKO
250 ME

OEKO
300

electrical (kW)

100

150

200

250

300

thermal (kW)

138

203

240

286

325

energy input (kW)

310

458

571

709

805

MAN
E 2876 TE

MAN
E 2876 LE

MAN
E 2876 LE

MAN
E 2842 LE

MAN
E 2842 LE

6R

6R

8V

12V

12V

12820cm

12820cm

14620cm

21930cm

21930cm

Generator (%) cos phi = 1

93,8

93,8

94,0

94,1

94,6

electrical (%)

32,3

32,8

35,0

35,3

37,3

thermal (%)

44,5

44,3

42,0

40,3

40,4

allover (%)

76,8

77,1

77,0

75,6

77,7

outlet max (C)

85

85

85

85

85

inlet max (C)

70

70

70

70

70

110

110

110

110

110

3,2x1,2x2,0

3,2x1,2x2,0

3,5x1,4x2,0

3,8x1,6x2,2

3,8x1,6x2,2

continuos output

engine typ
number of cylinders

cylinder capacity

efficiency

temperatures

exhaust gas (C)

dimensions
LxBxH (m)

Power plant construction Sommer-energy


Important constructed point: So few components as possible in the
motor frame.
Advantage:
- vibration decoupling increasing service life and reliability of
attachment parts
- easily accessibility to engine and generator for maintenance and
servicing
- use exclusively threaded and welded connectors
- not any extruded tubes
- large diameter and dimensioning of tubes, pumps, heat exchangers
etc.
- high reliability by big lubricating oil volumes

Ranges of application

multiple dwelling units, apartment blocks


hotels
hospitals
industrial facilities
agricultural holdings
schools
administrative buildings
pools and saunas
district heating connections
slaughterhouses, dairies, laundries,...

CHP 190 kW

CHP 250 kW

CHP 350 kW

Soud absorbing box

Biogas-CHP-container

Biog plant

CHP-garage

Customer satisfaction
...are very important for us!
before and after the installation we are attainable for you
one-stop service sales, consultancy and customer
support
maintenance and full service agreements
detailed plants and machinery documents
training and instruction
delivery of spare parts
according to customers wishes remote monitoring of plant
CHP contracting, rental or leasing basis
maintenance friendly system keeps the operating costs
low

V. Lyubimtsev
O.O.O.

Headquarters
BHK-systeme GmbH
Berlin

Manufacture &
Development
SOMMER energy
Deuna

Association of Companies
SOMMER energy
V. Lyubimtsev O.O.O.
BHK-systeme GmbH