Você está na página 1de 3

WindPRO version 2.6.1.

252 Jan 2009


Project:

Description:

Printed/Page

Iulia Project

Tulcea

11/24/2009 1:59 PM / 1
Licensed user:

NEK Umwelttechnik AG
Clausiusstrasse 41
CH-8033 Zrich
+41 44 261 07 07
C-TECH SRL
Calculated:

11/24/2009 1:59 PM/2.6.1.252

PARK - Main Result


Calculation: Park Eficiency - New Layout Gamesa
Wake Model

N.O. Jensen (RIS/EMD)

Calculation Settings
Air density calculation mode
Individual per WTG
Result for WTG at hub altitude
1.202 kg/m3 to 1.213 kg/m3
Hub altitude above sea level (asl) 180.0 m to 270.0 m
Annual mean temperature at hub alt.11.2 C to 11.7 C
Pressure at WTGs
981.0 hPa to 991.6 hPa
Wake Model Parameters
Wake Decay Constant0.075

Scale 1:100,000
New WTG

Calculated Annual Energy for Wind Farm


WTG combination
Wind farm

Annual Energy
Park
Capacity Factor for
Result Result-10.0% Efficiency Mean WTG energy Result Result-10.0%
[MWh]
[MWh]
[%]
[MWh]
[%]
[%]
98,470.5
88,623.5
94.1
5,792.4
33.0
29.7

Calculated Annual Energy for each of 17 new WTG's with total 34.0 MW rated power
WTG type
Terrain Valid Manufact. Type-generator

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

GAMESA
GAMESA
GAMESA
GAMESA
GAMESA
GAMESA
GAMESA
GAMESA
GAMESA
GAMESA
GAMESA
GAMESA
GAMESA
GAMESA
GAMESA
GAMESA
GAMESA

G87/2000-2,000
G87/2000-2,000
G87/2000-2,000
G87/2000-2,000
G87/2000-2,000
G87/2000-2,000
G87/2000-2,000
G87/2000-2,000
G87/2000-2,000
G87/2000-2,000
G87/2000-2,000
G87/2000-2,000
G87/2000-2,000
G87/2000-2,000
G87/2000-2,000
G87/2000-2,000
G87/2000-2,000

Power curve
Power, Rotor
Hub
Creator Name
rated
diameter height
[kW]
2,000
2,000
2,000
2,000
2,000
2,000
2,000
2,000
2,000
2,000
2,000
2,000
2,000
2,000
2,000
2,000
2,000

[m]
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0
87.0

[m]
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0

EMD
EMD
EMD
EMD
EMD
EMD
EMD
EMD
EMD
EMD
EMD
EMD
EMD
EMD
EMD
EMD
EMD

Level 0 - official - - 08-2004


Level 0 - official - - 08-2004
Level 0 - official - - 08-2004
Level 0 - official - - 08-2004
Level 0 - official - - 08-2004
Level 0 - official - - 08-2004
Level 0 - official - - 08-2004
Level 0 - official - - 08-2004
Level 0 - official - - 08-2004
Level 0 - official - - 08-2004
Level 0 - official - - 08-2004
Level 0 - official - - 08-2004
Level 0 - official - - 08-2004
Level 0 - official - - 08-2004
Level 0 - official - - 08-2004
Level 0 - official - - 08-2004
Level 0 - official - - 08-2004

Annual Energy
Park
Result Result-10.0% Efficiency

[MWh]
5,540.9
6,137.1
6,305.4
6,175.6
6,107.0
5,617.5
5,581.8
5,259.6
5,432.9
5,639.9
6,197.9
5,271.8
5,287.6
5,645.6
5,923.0
6,126.5
6,220.5

[MWh]
4,987
5,523
5,675
5,558
5,496
5,056
5,024
4,734
4,890
5,076
5,578
4,745
4,759
5,081
5,331
5,514
5,598

WTG siting
Romania Stereo 70
East
North
Z Row data/Description
Romania Stereo 70
[m]
1 New
779,949 397,124 80.0 WT 1
2 New
780,808 398,354 160.0 WT 10
Continued on next page...
WindPRO is developed by EMD International A/S, Niels Jernesvej 10, DK-9220 Aalborg , Tlf. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk

[%]
95.1
92.6
94.0
94.5
97.8
95.9
95.0
95.9
97.0
93.6
96.5
90.8
92.3
89.7
91.0
94.9
94.3

Mean
wind
speed
[m/s]
6.8
7.3
7.4
7.3
7.1
6.9
6.9
6.7
6.7
6.9
7.2
6.8
6.8
7.1
7.2
7.2
7.3

WindPRO version 2.6.1.252 Jan 2009


Project:

Description:

Iulia Project

Tulcea

PARK - Main Result


Calculation: Park Eficiency - New Layout Gamesa
...continued from previous page
Romania Stereo 70
East
North
Romania Stereo 70
3 New
780,485 398,763
4 New
780,128 398,661
5 New
780,702 400,309
6 New
780,316 401,081
7 New
780,439 401,659
8 New
780,156 401,953
9 New
780,515 402,206
10 New
780,650 397,189
11 New
781,716 397,245
12 New
780,111 397,540
13 New
780,002 397,882
14 New
780,381 397,884
15 New
780,473 398,217
16 New
781,532 397,721
17 New
781,246 398,045

Z
[m]
170.0
155.9
160.0
150.0
160.0
151.1
159.6
103.7
140.0
89.5
92.6
126.6
148.7
140.0
153.6

Row data/Description
WT 11
WT 12
WT 13
WT 14
WT 15
WT 16
WT 17
WT 2
WT 3
WT 4
WT 5
WT 6
WT 7
WT 8
WT 9

WindPRO is developed by EMD International A/S, Niels Jernesvej 10, DK-9220 Aalborg , Tlf. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk

WindPRO version 2.6.1.252 Jan 2009


Project:

Description:

Printed/Page

Iulia Project

Tulcea

11/24/2009 2:00 PM / 1
Licensed user:

NEK Umwelttechnik AG
Clausiusstrasse 41
CH-8033 Zrich
+41 44 261 07 07
C-TECH SRL
Calculated:

11/24/2009 1:59 PM/2.6.1.252

PARK - Production Analysis


Calculation: Park Eficiency - New Layout Gamesa
Directional Analysis

WTG:

All new WTG's, Air density varies with WTG position 1.202 kg/m3 - 1.213 kg/m3

Sector
0N
1 NNE 2 ENE
3E
4 ESE 5 SSE
6S
7 SSW 8 WSW
9 W 10 WNW 11 NNW
Total
Roughness based energy
[MWh]
17,332.2 12,787.3 8,049.0 5,372.2 6,936.2 6,843.5 5,410.5 3,924.2 8,404.4 12,155.2 7,350.6 10,042.0 104,607.4
-Decrease due to array losses[MWh]
1,229.2
499.5 335.2 250.0 392.1 605.7 558.1 285.8
439.4
489.6
338.2
714.2
6,136.8
Resulting energy
[MWh]
16,103.0 12,287.9 7,713.8 5,122.2 6,544.1 6,237.8 4,852.4 3,638.4 7,965.1 11,665.5 7,012.4 9,327.8 98,470.5
Specific energy
[kWh/m2]
974
Specific energy
[kWh/kW]
2,896
Decrease due to array losses [%]
7.1
3.9
4.2
4.7
5.7
8.9
10.3
7.3
5.2
4.0
4.6
7.1
5.9
Utilization
[%]
29.7
25.3
25.8
31.9
37.2
35.4
35.5
37.0
30.8
29.0
35.3
32.5
30.6
Operational
[Hours/year]
1,082
760
555
483
666
665
534
445
640
740
570
686
7,826
Full Load Equivalent
[Hours/year]
474
361
227
151
192
183
143
107
234
343
206
274
2,896

WindPRO is developed by EMD International A/S, Niels Jernesvej 10, DK-9220 Aalborg , Tlf. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk