Building Circuit Protection Devices

Catalogue 2011

MCB MCB Changeover RCCB RCBO Distribution Board

Safety Ensured

Standard Electricals Ltd (SEL), a flagship company of the Rs 5500 Crores (US $ 1.2 Billion) professionally managed group QRG Enterprises is a market leader in the field of low voltage electrical distribution & consumer electrical products. The company has carved a niche in the switchgear market by constantly creating innovative solutions and upgrading the product range to meet the ever-changing needs of the discerning customers. SEL started its manufacturing operations with conventional Rewirable Switch Fuse units over four decades ago. The product range today includes highly sophisticated domestic & industrial products such as MCBs, RCCBs, RCBOs, Distribution Boards (DBs), MCCBs, Changeover Switches, Switch Disconnector Fuses (SDFs), HRC Fuses, CFLs etc.. All products are designed to comply with major Indian & International Standards and are tested at CPRI/ERDA Laboratories. The quality control systems of the company have been audited by BVQI and the company is certified for ISO 9001: 2000. STANDARD brand of MCBs are CSA, CE, and KEMA marked & being exported to many European & Middle-East Countries. SEL emphasises on Research & Development which is the lifeline of the company. The Company uses state-ofthe-art CAD/CAM for the entire stage of design and development. It has complete in-house facilities for short circuit testing upto 10kA and all related equipments for conducting electrical / mechanical tests. The company has its manufacturing plant in Haridwar (Uttarakhand), with a work force of more than 500 people including 100 qualified engineers. STANDARD brand has a wide customer base through its nationwide marketing network having offices in all major cities in India with over 750 Authorised Dealers for effective sales & services. SEL products are now available internationally having a strong export base. Its products are being exported to the Middle East, South East Asian countries, Malaysia, Singapore, Germany, U.K., South Africa, Kenya, Ghana, Nigeria.

CONTENTS
Miniature Circuit Breaker (MCB) MCB Changeover Switch Residual Current Circuit Breaker (RCCB/ELCB) Residual Current Circuit Breaker with Over Current Protection (RCBO) Distribution Boards (DB) 32 28 6 16 20

MINIATURE CIRCUIT BREAKER

Range 6A-40A (B Type) 0.5A-63A (C Type) 0.5A-63A (D Type) Execution SP, SPN, DP, TP, TPN & FP Specification IS / IEC : 60898-1

Electricity is an inseparable part of our daily lifestyle. In residential, commercial and industrial sectors there are myriad systems, equipments and sophisticated appliances that depend on electrical energy. Uncontrolled electrical power can be extremely dangerous. Overloads, crowded wiring, short-circuits and all kinds of interruptions in electric supply can lead to devastating losses, least of them being financial. We at STANDARD are proud to be known and respected the world over for our range of superior quality electrical control and safety devices. Through these, we speak of our lasting concern for safety, economy and productivity for our customers. The latest product from STANDARD is 10kA MCB, is an advanced Indian design of high performance, current limiting and switching for control and protection of industrial, commercial & domestic electrical sub circuits. It meets the latest specification IS / IEC : 60898-1 of B & C Characteristics. The primary function of the MCB is to protect the installation such as cable & other components from damage, resulting due to overload & short-circuit fault. Under overload heating effect can occur on cable. Protection in this respect is assured by matching the cable rating to the current rating of MCB. Under short-circuit condition, mechanical damage can occur due to strong magnetic field caused by high current peaks and overheating of cables on account of "exclusive let through energy". The current limiting action of "MCB" ensures low value of both peak current "cut off" and minimum let through energy.

Features & Benefits


Design Latest & one of the best designed MCB. Higher performance in a smaller package. MCBs conforms to the latest Standards IS / IEC : 60898-1 / 2002. These MCBs provide reliable protection to circuits against overload & short-circuit ideal for industrial, commercial & residential installations. Certifications ISI Higher breaking capacity Breaking capacity of 10kA for the complete range from 6A to 63A in single pole and multipole tested at CPRI. Larger terminals Dual termination facility for incoming side and can take wire upto 25sq. mm cross section. Wire may be of copper or aluminum. Shock proof Offer IP 20 degree of protection. All live parts are out of human reach ensuring safety to user. Longer life Reduced electro magnetic stresses resulting in increased contact life. Flexibility Can be mounted easily in any of the Boards. Energy saving IS / IEC : 60898-1 have recognized the growing importance of limiting power loss in Switchgear devices and stipulated max. permissible power loss values per pole of MCB. MCB having power loss figures of 50% lower watts than IS requirement. Thus, 50% energy & cost saving by application. 7 regular Distribution

PROTECTION UNLIMITED STANDARD MCBs protect against overload and short circuit.
Overload Protection It is achieved by thermal operation of the bimetal strip which deflects when heated by the over current going through it, thereby tripping the operating mechanism and causing the contact to open. Thermostatic Bi-metal It is a composite material comprising of two metallic layers of different co-efficient of thermal expansion which are permanently bonded together by pressure welding. Short Circuit Protection In short circuit, the high current in the range of kA energises the solenoid and a magnetic field is created. Due to this magnetic field the anchor is pulled down which pushes the plunger to strike the inner latch, causing instantaneous opening of the contacts.

CHARACTERISTIC CURVES
Thermal Tripping As per No tripping Current I1 1.13 x In 1.45 x In 1.13 x In 1.45 x In 1.13 x In 1.45 x In Tripping Current I2 Time Limits t >1h <1h >1h <1h >1h <1h 10xIn 20 x In 5xIn 10 x In Magnetic Tripping Hold Trip Time Limits t >0.1s 5 x In <0.1s >0.1s <0.1s >0.1s <0.1s
0.10 10000.00

IS / IEC 60898-1 B Curve

Current Current I4 3xIn I5

1000.00

Time (sec.)

100.00

10.00

C Curve

1.00

D Curve

0.01

l3 = 2.55 x lN

1 s < t < 60s for ln < 32A 1 s < t < 120s for ln > 32A

10

20

30

100

1.13 1.45 Multiples of Rated Current (x In)

TIME CURRENT CHARACTERISTIC CURVES


Based on the Tripping Characteristics, Standard MCBs are available in B, C and D curve to suit different types of applications. B Curve: for protection of electrical circuits with equipment that does not cause surge current (lighting and distribution circuits). Short circuit release is set to (3 - 5) In C Curve: for protection of electrical circuits with equipment that causes surge current (inductive loads and motor circuits). Short circuit release is set to (5 - 10) In D Curve: for protection of electrical circuits which causes high inrush current, typically 12-15 times the thermal rated current (transformers, X-ray machines etc.) Short circuit release is set to (10 - 20) In CURRENT LIMITING DESIGN In a current limiting breaker, the tripping & arc control mechanism is so designed that under short circuit conditions, the contacts are physically separated and the electrodynamic forces set up by fault current assist the extinction in less than half cycle. The figure shows the current limiting effect of a circuit breakers. Fault Traces for Voltage & Current 0 = Point of fault initiation tx = Contact opening time (i.e., creation of arc) t1 = Current / Voltage peak (i.e., current limitation) t2 = Time to total extinction of arc (i.e., complete shutdown of fault current) 8
Current A Cut-off Current 0 Voltage Voltage across contacts during opening of MCB

Time Maximum Prospective Fault Current

0 tX t1

t2

MINIATURE CIRCUIT BREAKER

POWER LOSS DETAILS


S. No. MCB Rating (A) 6 8 10 16 20 25 32 40 63 STANDARD MCBs Power Loss (W) 0.9 1.1 1.6 2.5 2.8 3.2 3.4 4.9 7.3 Max. Permissible Power Loss (W) As per IS:8828/IEC:60898 3.0 3.0 3.0 3.5 4.5 4.5 6.0 7.5 13

1 2 3 4 5 6 7 8 9

TECHNICAL INFORMATION
MCB Standard Conformity Type/Series Rated Current (In) Rated Voltage (ac) (Ue) Rated Frequency (f) Nos. of Poles (Execution) Rated Short Circuit Breaking Capacity Utilization Category Magnetic Release Setting Rated Insulation Voltage (Ui) Rated Impulse Voltage (Uimp) Electrical / Mechanical Endurance Endurance (No. of operations) Less than 32A More than 32A Ambient Temperature Terminal Capacity (Max) Vibration Shock Protection Class Installation Position Mounting Case & Cover (oC) sq.mm 25 3 40 mm free fail IP - 20 Vertical / Horizontal Clip on DIn Rail (35 mm x 7.5 mm) Moulded, flame retardant thermoplastic material. ** SP Single Pole DP Double Pole TP Three Pole TP + N Three Pole Neutral FP Four Pole V kV (3-5)In (5-10)In 690 4 kA 10 A V Hz B 6 - 40* IS / IEC 60898-1 C 0.5 - 63* 240/415 50 SP, SPN, DP, TP, TPN, FP ** 10 6 to 32 - 10KA 40 to 63 - 4.5kA (10-20)In AC 22A in 40A & 63 AC 23A in 100A & 125A 690 4 D*** 0.5 - 63* 40 - 125 240/415 50 SP, DP, TP,FP** Isolator IS / IEC 60947 - 3

20,000 10,000 -5 to +45

10000

25 5

*Current Ratings - 0.5A, 1A, 2A, 3A, 4A, 5A, 6A, 8A, 10A, 13A, 16A, 20A, 25A, 32A, 40A, 50A, 63A *** D Type MCB are available on request

DIMENSIONS (in mm)


17.7 35.4 53.1

70.8

60 44

45

36

84

1 POLE

1 POL E + NEUTRAL & 2 P OL E

3 POLE

3 POL E + NEUTRAL & 4 POLE

70.5

MINIATURE CIRCUIT BREAKER

MCB Single Pole (SP)


Current Rating (Amps.) 0.5 1 2 2.5 3 5 6 10 16 20 25 32 40 50 63 Cat No. B-Curve DSMSBSPF006 DSMSBSPF010 DSMSBSPF016 DSMSBSPF020 DSMSBSPF025 DSMSBSPF032 DSMSBSPF040 -

C-Curve DSMSCSPF0X5 DSMSCSPF001 DSMSCSPF002 DSMSCSPF2X5 DSMSCSPF003 DSMSCSPF005 DSMSCSPF006 DSMSCSPF010 DSMSCSPF016 DSMSCSPF020 DSMSCSPF025 DSMSCSPF032 DSMSCSPF040 DSMSCSPF050 DSMSCSPF063

MCB SINGLE POLE NEUTRAL (SPN)


Current Rating (Amps.) 0.5 1 2 2.5 3 5 6 10 16 20 25 32 40 50 63 Cat No. B-Curve C-Curve DSMSCSNF0X5 DSMSCSNF001 DSMSCSNF002 DSMSCSNF2X5 DSMSCSNF003 DSMSCSNF005 DSMSCSNF006 DSMSCSNF010 DSMSCSNF016 DSMSCSNF020 DSMSCSNF025 DSMSCSNF032 DSMSCSNF040 DSMSCSNF050 DSMSCSNF063

MCB DOUBLE POLE (DP)


Current Rating (Amps.) 0.5 1 2 2.5 3 5 6 10 16 20 25 32 40 50 63 Cat No. B-Curve -

C-Curve DSMSCDPF0X5 DSMSCDPF001 DSMSCDPF002 DSMSCDPF2X5 DSMSCDPF003 DSMSCDPF005 DSMSCDPF006 DSMSCDPF010 DSMSCDPF016 DSMSCDPF020 DSMSCDPF025 DSMSCDPF032 DSMSCDPF040 DSMSCDPF050 DSMSCDPF063

10

MINIATURE CIRCUIT BREAKER

MCB TRIPLE POLE (TP)


Current Rating (Amps.) 0.5 1 2 2.5 3 5 6 10 16 20 25 32 40 50 63 Cat N o. B-Curve -

C-Curve DSMSCTPF0X5 DSMSCTPF001 DSMSCTPF002 DSMSCTPF2X5 DSMSCTPF003 DSMSCTPF005 DSMSCTPF006 DSMSCTPF010 DSMSCTPF016 DSMSCTPF020 DSMSCTPF025 DSMSCTPF032 DSMSCTPF040 DSMSCTPF050 DSMSCTPF063

MCB TRIPLE POLE NEUTRAL (TPN)


Current Rating (Amps.) 0.5 1 2 2.5 3 5 6 10 16 20 25 32 40 50 63 Cat No. B-Curve -

C-Curve DSMSCTNF0X5 DSMSCTNF001 DSMSCTNF002 DSMSCTNF2X5 DSMSCTNF003 DSMSCTNF005 DSMSCTNF006 DSMSCTNF010 DSMSCTNF016 DSMSCTNF020 DSMSCTNF025 DSMSCTNF032 DSMSCTNF040 DSMSCTNF050 DSMSCTNF063

MCB FOUR POLE (FP)


Current Rating (Amps.) 0.5 1 2 2.5 3 5 6 10 16 20 25 32 40 50 63 Cat No. B-Curve C-Curve DSMSCFPF0X5 DSMSCFPF001 DSMSCFPF002 DSMSCFPF2X5 DSMSCFPF003 DSMSCFPF005 DSMSCFPF006 DSMSCFPF010 DSMSCFPF016 DSMSCFPF020 DSMSCFPF025 DSMSCFPF032 DSMSCFPF040 DSMSCFPF050 DSMSCFPF063

11

ISOLATOR

ISOLATOR
TECHNICAL SPECIFICATION-ISOLATOR
Range 40A, 63A, 100A and 125A Execution SP, DP, TP, & FP Specification IS / IEC: 60947-3 Rated Voltage 240V / 415V AC Rated Frequency 50 Hz Utilisation Category AC 22A in 40A and 63A AC 23A in 100A and 125A Electrical Endurance 10000 operations Mechanical Endurance 20000 operations Terminal Capacity 40A, 63A 100A, 125 A Flexible 16 sq.mm 35 sq.mm Solid 25 sq.mm 50 sq.mm

ISOLATOR SINGLE POLE (SP)


Rating(A) 40 63 100 125 Cat No. DSMISOSPX040 DSMISOSPX063 DSMIOSPX100 DSMIOSPX125

ISOLATOR DOUBLE POLE (DP)


Rating(A) 40 63 100 125 Cat No. DSMISODPX040 DSMISODPX063 DSMIODPX100 DSMIODPX125

12

ISOLATOR

ISOLATOR TRIPLE POLE (TP)


Rating(A) 40 63 100 125 Cat No. DSMISOTPX040 DSMISOTPX063 DSMIOTPX100 DSMIOTPX125

ISOLATOR FOUR POLE (FP)


Rating(A) 40 63 100 125 Cat No. DSMISOFPX040 DSMISOFPX063 DSMIOFPX100 DSMIOFPX125

13

MINIATURE CIRCUIT BREAKER

ACCESSORIES
AUXILLARY CONTACT
Standard Conformity IS / IEC : 60947-1 Rated Current (In) 6A Rated Voltage (Ue) 240 V ac Contact Configuration 1 NO + 1 NC 2 NO + 2 NC Utilization Category AC 11 Electrical Endurance (nos. of operations) 10000 Terminal Capacity (max) 4mm2 Protection Class IP - 20 as per IS : 2147 & IEC : 60529 Mounting Left side of MCB (Factory assembled)

SHUNT TRIP ATTACHMENT USED FOR REMOTE TRIPPING


Standard Conformity IS / IEC : 60947-3 Coil Consumption 6VA Rated Voltage (ac) (Ue) 240V Frequency 50Hz Operating Voltage range 70% - 110% of rated voltage Electrical Endurance (nos. of ops) 10000 Terminal Capacity (max) 25mm2 Protection Class IP - 20 as per IS-2147 & IEC-60529 Mounting Right side of MCB (Factory assembled) (dc) (Ue) 48V, 24V, 12V

14

MINIATURE CIRCUIT BREAKER

SHUNT TRIP COIL


To trip the Circuit Breaker through Shunt Trip Coil, 70% to 110% of the rated voltage is to be applied across D1 & D2 The Shunt Trip coil is short time rated and it trip the breaker instantaneously. (i.e., continuous duty not required)
Shunt trip Connection Digram Outgoing D1 CoilTerminal

1 3

2 4

Incoming

D2 CoilTerminal

Incoming Connection

MCB SELECTION CHART


Appliance Air Conditioner Capacity / wattage (1, 240V~) 1.0 tonnes 1.5 tonnes 2.0 tonnes 165 litres 350 litres 4500W 1750W 750W 2000W 1000W 2000W 300W 1300W 1000W 2000W 3000W 6000W 750W 1250W 1200W 1500W MCB Current Rating 10A 16A 20A 3A 4A 32A 10A 6A 10A 6A 10A 2A 8A 6A 10A 16A 32A 6A 8A 8A 10A MCB Type C C C C C B B B B B B C series series series series series series series series series series series series

Refrigerator Oven cum Griller Oven Hot plate Room Heater Washing Machine Washing Machine (with heater) Water Heater (storage/instant)

C series B B B B B B series series series series series series

Electric iron Toaster (2 slices) Electric Kettle

B series B series

15

Range

MCB CHANGEOVER SWITCH

25A, 40A Execution Double Pole, Four Pole Specification IS / IEC : 60947-3

16

MCB Changeover switch finds wide & varied applications in industries as well as in domestic sphere for use in low voltage distribution circuits, wherever continuity of supply is necessary, for switching to an alternate source of supply from main supply and vice - versa. They are switch disconnectors with independent manual operation, capable of making, carrying and breaking currents under normal circuit conditions, which may include operating overload condition and also carry currents under specified abnormal circuit conditions such as those of short circuit for a specified time.

Features
Compact construction Double break contacts Silver Cadmium Oxide contact tips Shrouded terminals Front operation with three stable positions I-O-II Centre position OFF Easy snap on DIN Rail mounting Can be mounted with other products viz. MCB, RCCB, Isolator in Distribution Board

CONSTRUCTION
The entire switching mechanism along with the fixed and moving contact assembly are housed in FR thermo plastic moulded case / cover, having high dielectric strength, excellent mechanical & thermal properties. The switching mechanism is double break type. The contact tips are made of Silver Cadmium oxide for long electrical life, sustained current carrying capacity and they ensure temperature rise is within specified limits.

TECHNICAL INFORMATION
Standard Confirmity No. of Poles (Execution) Rated Current (In) Rated Voltage (Ue) Rated Frequency Rated insulation voltage Dielectric Strength Rated impulse voltage Utilization Category Ambient Temp. Mechanical life Electrical life Mounting Mounting Position Terminal Capacity sq. mm C Nos. ops. Nos. ops. A V Hz V kV kV IS/IEC-60947-3 : DP, FP : 25, 40 : 240 AC / 415 AC : 50 : 660 : 2.5 : 4 : AC 21A : -5 to +55 : 10000 : 10000 : Standard DIN rail : Vertical / Horizontal : 10

17

MCB CHANGEOVER SWITCH

CONNECTION DIAGRAMS / TERMINAL MARKING Double Pole


Current Rating (Amps.) 25 40 Cat. No. DSMCODPX025 DSMCODPX040

I II *

Incoming terminals (main supply) Incoming terminals (standby supply) Outgoing terminals (to load) Mid position of knob is OFF position

-2&6 -4&8 -1&5

DIMENSIONS (in mm)

18

MCB CHANGEOVER SWITCH

Four Pole
Current Rating (Amps.) 25 40 Cat. No. DSMCOFPX025 DSMCOFPX040

13

10

12

14

16

I II *

Incoming terminals (main supply) Incoming terminals (standby supply) Outgoing terminals (to load) Mid position of knob is OFF position

- 2, 6, 10 & 14 - 4, 8, 12 & 16 - 1, 5, 9 & 13

DIMENSIONS (in mm)

19

Range 16A - 63A Execution 2 Pole, 4 Pole Specification IS 12640 - 1: 2008 IEC 61008 - 1

RCCB / ELCB

20

The flow of current through electrical facilities always involves risks. Poorly insulated equipment, faulty wires and incorrect use of an electrical device cause currents to flow through the wrong path (i.e. through the insulation) to the earth. This current is called Leakage Current. Earth leakage is an electrical hazard and is responsible for electrical shocks and fire risk. Earth leakage and its associated hazard can be prevented by Residual Current Circuit Breaker (RCCB), also popularly known as Earth Leakage Circuit Breaker (ELCB).

Features & Benefits


Features Simple and Robust operating mechanism. Rotary handle with ON/OFF indication Dual termination for Bus Bar as well as cable connection Advance neutral Test button for regular inspection Positive contact indication Range 16A - 63A Sensitivity 30mA, 100mA, 300mA Execution Double Pole (DP) Four Pole (FP) Specification IEC 61008-1/IS 12640 - 1:2000 Against Electrocution The use of exposed, substandard, badly wired, wrongly connected or damaged equipment as well as frayed or badly repaired cables reduces the safety of an installation and increases the risk of person receiving an electric shock. Electrocution is a passage of current through human body, which is dangerous. The flow of current through human body effects vital functions. 1. Breathing 2. Heartbeat A correctly chosen RCCB can detect small currents flowing to earth and reduces the risk of electrocution. Effect of electric current through human body has been well researched and following chart summarizes the results: Effect of electric current through human body has been well researched and following chart summarizes the results

21

RCCB/ELCB

PROTECTION Against Electrocution


The use of exposed, substandard, badly wired, wrongly connected or damaged equipment as well as frayed or badly repaired cables reduces the safety of an installation and increases the risk of person receiving an electric shock. Electrocution is a passage of current through human body, which is dangerous. The flow of current through human body effects vital functions. 1. Breathing 2. Heartbeat A correctly chosen RCCB can detect small currents flowing to earth and reduces the risk of electrocution. Effect of electric current through human body has been well researched and following chart summarizes the results. Effect of electric current through human body has been well researched and following chart summarizes the results.

EFFECT OF ELECTRIC CURRENT THROUGH HUMAN BODY


500 mA Immediate cardiac arrest resulting in death

70-100 mA

Cardiac fibrillation; the heart begins to vibrate and no

20-30 mA

Muscle contraction can cause respiratory paralysis

10 mA

Muscle contraction : the person remains stuck to the conductor

1-10 mA

Prickling sensations

However, electrocution should not be viewed in terms of current alone, but in terms of contact voltage. A person gets electrocuted by coming in contact with an object that has a different potential from his/her own. The difference in potential causes the current to flow through the body. The human body has known limits: Under normal dry conditions, voltage limit = 50V In damp surroundings, voltage limit = 25V

Rated Tripping Current of the RCD 10 mA 30 mA 100 mA 300 mA

Maximum permissible earth fault loop impedance in 5,000 1,666 500 166

AGAINST INDIRECT CONTACT Over current protection devices like MCB are unable to act promptly on small earth leakage currents. To comply with wiring regulations, the earth fault loop impedance in Ohms, multiplied by the rated tripping current of the RCD in amperes must not exceed 50.

Example For an RCD with a rated tripping current of 30mA, the maximum permissible earth fault loop impedance is calculated as follows: Zs (max) = 50 / In = 50/0.03 = 1,666

AGAINST FIRE
The majority of fires which occur as a result of faulty wiring are started by current flowing to earth. Fire can be started by fault current of less than 1 amp.The normal domestic overload protective device such as a fuse or MCB will not detect such a small current. A correctly chosen RCD will detect this fault current and interrupt the supply, hence, reducing the risk of a fire starting.

22

RCCB/ELCB

Technical Information Standard Conformity Rated Current (In) A Sensitivity * (In) mA Rated Voltage (Un) Vac Rated Insulation Voltage (Ui) V Rated Frequency Hz Short circuit Withstand Capacity kA Residual Making Breaking Capacity A Ambient Temperature C Shock Resistance Vibration Resistance g Electrical /Mechanical operations Mounting Degree of Protection Terminal Capacity (max) mm2 *500 mA is available on request

TWO POLE IS 12640-1: IEC 61008-1 16, 25, 32, 40, 63 30, 100, 300 240 690 50 6 500 A or 10 In wherever is greater -25C to + 55C 40 mm free fall 3 10000 Din Rail (35 x 7.5) mm IP 20 25

FOUR POLE IS 12640-1: IEC 61008-1 25, 40, 63 30, 100, 300 415 690 50 6 500 A or 10 In wherever is greater -25C to + 55C 40 mm free fall 3 10000 Din Rail (35 x 7.5) mm IP 20 25

WORKING PRINCIPLE
The RCCB works on the current balance principle. The supply conductors, i.e. the phases and the neutral, are passed through a torroid and form the primary windings of a current transformer. Its secondary winding is connected to a highly sensitive electromagnetic trip relay, which operates the trip mechanism. In a healthy circuit, sum of the currents in phases, is equal to the current in the neutral and the vector sum of all currents is equal to zero. If there is any insulation fault in the current and leakage current flows to earth, the currents do not balance and their vector sum is not equal to zero. This imbalance is detected by the core balanced current transformer, the RCCB is tripped and supply to load is interrupted. The trip mechanism is operated at a residual current between 50-100% of its rated tripping current.

R Y B N

Earth

23

RCCB/ELCB

SELECTION
30 mA : A 30 mA ELCB will provide a high degree of protection against electrocution in an accidental shock hazard situation. The current flowing through human body could be between 80mA and 240mA depending on the resistance of the human body and the voltage across it. Zone : Physiological Effects Zone 1 : Usually no reactions Zone 2 : Usually no harmful physiological effects Zone 3 : Usually no organic damage to be expected. Likelihood of muscular contraction and difficulty in breathing, reversible disturbances of formation and conduction of impulse in the heart and transient cardiac arrest without ventricular fibrillation increases with current magnitude and time. Zone 4 : In addition to the effects of Zone 3, probability if ventricular fabriliation increased upto 5% (curve C2) upto 50% (curve C3) and above 50% beyond curve C3. It increases with magnitude and time, and pathophysiological effects such as cardiac arrest, breathing arrest and heavy burns may occur. To be within zone of the IEC curve as shown above. It is necessary for the ELCB to operate within 50ms at 240 mA and 150ms at 80mA. Both these conditions are satisfied by 30mA ELCB. For households, individual outlets, wet areas and temporary installations, ELCB with sensitivity not exceeding 30mA is advisable. 100 mA : A 100mA ELCB will normally give high degree of protection against electrocution but there is a possibility that the shock current could fall below the tripping level of ELCB. This could occur if additional resistances to that of human body are included in the earth path. The 100mA RCCB protects against leakage currents and indirect contact with earth loop impedance upto 500 Ohms. 300 / 500mA : A 300/500 mA ELCB may be used where only fire protection is required. eg., on lighting circuits, where the risk of electric shock is small. 300/500mA ELCB will not give any protection against electrocution.
Time (in ms) ms
10000 5000 2000 1000 a b c1c2c3

Time in milliseconds

500 200 100 50 20 10 0.1

0.3 1 0.2 0.5

10

20

30

50

100

300 1000 3000 10000 200 500 2000 5000

Current in milliamperes
30 mA 100 mA Typical current limits due to body resistance at 240 V

350

300

350

200

150

100

50

Residual Current multiple of In (mA)

Actuation Time Characteristics

WIRING DIAGRAM
For Single Phase 2 Wire connections
Load

For Three Phase 4 Wire connections


Load

For Three Phase 3 Wire connections


Load

1N

1 3 5N

1 3 5N

R T

R T 2 4 6N N 2 4 6 N

R T

2N 1

2 4 6N 2 4 6 N

The Standard range of four pole RCCBs can be used to provide residual current protection in 3 phase, 3 wire circuits (no neutral), however a link from the neutral to an incoming should be made on the supply side of the RCCB, to enable the operation of the RCCB.

24

RCCB/ELCB

AC TYPE

- STANDARD APPLICATIONS

AC type RCDs detect AC residual currents. In the majority of cses (standard applications), they are used for AC current detection at 50 / 60 Hz

DOUBLE POLE AC TYPE


Current Rating (Amps.) 16 16 16 25 25 25 32 32 32 40 40 40 63 63 63 Sensitivity mA 30 100 300 30 100 300 30 100 300 30 100 300 30 100 300 Cat No. DSRMCTDF030016 DSRMCTDF100016 DSRMCTDF300016 DSRMCTDF030025 DSRMCTDF100025 DSRMCTDF300025 DSRMCTDF030032 DSRMCTDF100032 DSRMCTDF300032 DSRMCTDF030040 DSRMCTDF100040 DSRMCTDF300040 DSRMCTDF030063 DSRMCTDF100063 DSRMCTDF300063

FOUR POLE AC TYPE


Current Rating (Amps.) 16 16 16 25 25 25 32 32 32 40 40 40 63 63 63 Sensitivity mA 30 100 300 30 100 300 30 100 300 30 100 300 30 100 300 Cat No. DSRMCRFF030016 DSRMCRFF100016 DSRMCRFF300016 DSRMCRFF030025 DSRMCRFF100025 DSRMCRFF300025 DSRMCRFF030032 DSRMCRFF100032 DSRMCRFF300032 DSRMCRFF030040 DSRMCRFF100040 DSRMCRFF300040 DSRMCRFF030063 DSRMCRFF100063 DSRMCRFF300063

Dimensions (in mm)


67.8 71.0 36.0 60.0 60.0 68.0

36.0

45.0

84.5

36.0

43.5

25

45.0

RCCB/ELCB

HIGHER RATING (80A-100A)


Range IS : 12640-1:2008 IEC : 61008-1:1996 Sensitivity 30, 100 & 300 mA Execution 2P, 4P Specification 50Hz Features Short circuit breaking with stand capacity 10kA Different knob position to indicate whether it is switched by a fault or manually switched OFF (mid trip) Test button for regular inspection Contact position indication

Technical Information Specification Reference Rated current (In) Sensitivity (IDn) Rated Voltage (Ue) Rated Insulation voltage (Ui) Rated Frequency Trip Time A mA V V Hz

TWO POLE IEC 61008-1 & IS 12640-1: 2008 80, 100 30, 100, 300 240 V~ 660 50 1xIDn<300ms 5IDn<40ms 10 10 In -25C to + 55C 40mm free fall 5 >2000 >3000 Din Rail (35 x7.5 mm) IP 20 50

FOUR POLE IEC 61008-1 & IS 12640-1: 2008 80, 100 30, 100 ,300, 500* 415V~ 660 50 1xIDn<300ms 5IDn<40ms 10 10 In -25C to + 55C 40mm free fall 5 >2000 >3000 Din Rail (35 x7.5 mm) IP 20 50

Short circuit withstand Capacity kA Residual Making Breaking capacity A Ambient Working Temperature C Shock Resistance Vibration Resistance g Electrical Endurance operations Mechanical Endurance operations Mounting Degree of protection Terminals Capacity (Max) mm2
*500 mA is available on request

26

RCCB/ELCB

DOUBLE POLE AC TYPE


Current Rating (Amps.) 80 80 80 100 100 100 Sensitivity mA 30 100 300 30 100 300 Cat No. DSRMCMDF030080 DSRMCMDF100080 DSRMCMDF300080 DSRMCMDF030100 DSRMCMDF100100 DSRMCMDF300100

FOUR POLE AC TYPE


Current Rating (Amps.) 80 80 80 100 100 100 Sensitivity mA 30 100 300 30 100 300 Cat No. DSRMCMFF030080 DSRMCMFF100080 DSRMCMFF300080 DSRMCMFF030100 DSRMCMFF100100 DSRMCMFF300100

Dimensions (in mm)

69.5 60.0 44.0 30.5 36.0 72.0

2 Pole

4 Pole

45.0

36.0

87.5

87.5

27

Range 6A, 10A, 16A, 20A, 25A, 32A & 40A Sensitivity 30mA, 100mA, 300mA Execution Single Pole with neutral (SPN) Triple Pole with neutral (TPN) Specification IS:12640 Part2: 2008, IEC 61009-1, BSEN:61009-1

RCBO

28

Standard New RCBO is a single composite device which provides protection against over currents and earth leakage faults in the same width and profile as that of a standard MCB. It is designed for use in domestic, commercial and industrial distribution systems at the most downstream circuit for ensuring high degree of protection to the user for a particular circuit. In normal use, it is safe to use and free of to user as well as to environment.

Features & Benefits


Features Pulsating dc protection - Type A Discrimination using time delay - Type S RCBO Controlled response VD RCBO (Electronic) Protection in case of loss of supply neutral in SPN RCBO only Enhanced immunity to nuisance tripping Positive contact indication: Red for ON , Green for OFF Short circuit breaking capacity 10 kA. Large terminal capacity: RCBOs have 35 mm2 for cool running while in operation. Protection in case of loss of supply neutral: Even in event of loss of supply neutral, Standard RCBO provides protection against earth faults . The Functional Earth (FE) white color wire connected to earth provides this protection. Controlled response & immunity to nuisance tripping: The trip level and the response time of the Standard VD (Voltage Dependent) RCBO using electronic circuit is set to very precise values and thereby provide greater immunity to nuisance tripping that can be caused by mains borne noise, surge voltages, lighting surges, reactive loads, mains filters, etc. Neutral to earth faults: A connection that occurs between N and E on the load side of any RCBO will impact on its performance and cause the trip level to increase. In the case of a N - E fault, the user may have no way of knowing that this fault exists and that the RCBO has been desensitised. Under this condition, the Standard VD RCBO provides a far greater level of protection than a normal VI (Voltage Independent) RCBO. Aesthetics & Convenience The new modules unique compact construction enables far more devices to be fitted into a distribution board than previously possible, and 2 Module RCBO can simply replace existing MCB 2 pole when upgrading a board. High stacking density = smaller chasis & distribution boards. Reliability & continuity of service Enhanced discrimination with Standard MCBs Back up to 10 kA with BS & DIN fuses Retrofits Standard MCBs in distribution boards with no modifications in general Robust construction. Energy limiting Standard RCBO meets the requirements for energy let through by IEC & British Standard for energy limiting class 3.

29

RCBO

ADDITIONAL RANGE - TYPE A & S


Type A - Pulsating DC Protection: Any electrical appliance with power control has the ability to produce earth fault currents with pulsating DC (rectified AC) components. RCBOs that provide this type of protection are referred to as Type A RCBOs. VI RCBOs do not provide this protection, and are referred to as Type AC RCBOs. Standard VD RCBOs have been specifically designed to provide protection against pulsating DC fault currents. Type S- Selective or Time Delay: RCBOs are also divided into two categories determined by their response time to an earth fault current, as follows General Type - having a trip time<300mS for fault currents of IDN and < 40ms for fault currents > 5 IDN. S Type- having a trip time of 150 - 500mS for IDN, and 40 - 130mS for >5 IDN. (IDn is the rated residual operating current of the RCBO) As the name implies, general types are intended for general purpose use. However, S (selective) types are normally used in conjunction with downstream general type RCBOs. The S type effectively provides discrimination in terms of the response time to earth fault currents for upstream and downstream RCBOs. For example, when two RCBOs are connected in series the first RCBO will often be an S type.

Technical Information Specification Specification Reference Rated Current In Rated Residual Operating Current IDN Instantaneous Tripping Current Rated Voltage Un (Vac) Rated Insulation Voltage Un (Vac) Rated Frequency No. of Pole Rated Short Circuit Capacity Icn Rated Residual Making Breaking Capacity IDm Operating Characteristics in case of Residual Currents Method of Mounting Degree of Protection Terminals for External Conductors (mm2) Net Weight (in Kg) Ambient Working Temperature Mechanical Endurance (No. of Operations) Electrical Endurance (No. of Operations) Trip Time (milli Second) Shock Resistance Vibration Resistance

SPN (2M) SPN (2M) IS 12640 (Part 2) & IEC 61009 6A, 10A, 16A, 20A,25A, 32A, 40A 30, 100, 300mA. C curve 240V~ 660V 50Hz 1P+N 10kA 500A A type Panel Board Type (DIN Rail) IP 20 35 0.420 -5C to + 55C 4000 4000 <40 40mm free fall 3g

TPN (4M) TPN (4M) IS 12640 (Part 2) & IEC 61009 6A, 10A, 16A, 20A,25A, 32A, 40A 30, 100, 300mA. C curve 415V~ 660V 50Hz 3P+N 10kA 500A A type Panel Board Type (DIN Rail) IP 20 0.84 -5C to + 55C 4000 4000 <40 40mm free fall 3g

30

RCBO

Time Current Characteristics C Curve


10000.00

Residual Current Tripping Characteristics (General Type)


1000.00

1000.00

100.00

100.00 10.00

10.00

Time (sec)
1.00 0.10 0.01 0.01

Time(sec)

1.00

0.10

0.01 1 10 100

10

100

1000

10000

Multiples of Reted Current

Multiples of Reted Residual Current in In mA

Current Rating (Amps.) 6 6 6 10 10 10 16 16 16 20 20 20 25 25 25 32 32 32 40 40 40

Sensitivity mA 30 100 300 30 100 300 30 100 300 30 100 300 30 100 300 30 100 300 30 100 300

Cat No. SP&N DSCEACSN2030006 DSCEACSN2100006 DSCEACSN2300006 DSCEACSN2030010 DSCEACSN2100010 DSCEACSN2300010 DSCEACSN2030016 DSCEACSN2100016 DSCEACSN2300016 DSCEACSN2030020 DSCEACSN2100020 DSCEACSN2300020 DSCEACSN2030025 DSCEACSN2100025 DSCEACSN2300025 DSCEACSN2030032 DSCEACSN2100032 DSCEACSN2300032 DSCEACSN2030040 DSCEACSN2100040 DSCEACSN2300040

Cat No. TP&N DSCEACTN4030006 DSCEACTN4100006 DSCEACTN4300006 DSCEACTN4030010 DSCEACTN4100010 DSCEACTN4300010 DSCEACTN4030016 DSCEACTN4100016 DSCEACTN4300016 DSCEACTN4030020 DSCEACTN4100020 DSCEACTN4300020 DSCEACTN4030025 DSCEACTN4100025 DSCEACTN4300025 DSCEACTN4030032 DSCEACTN4100032 DSCEACTN4300032 DSCEACTN4030040 DSCEACTN4100040 DSCEACTN4300040

Dimensions (in mm)


44 35.4 70.8 50.4

6.8 87.5 36 45 125

36

45

6.8

43.5 68.4 70.6

43.5 68.4 74.5

31

Range Single Phase & Three Phase Execution

DISTRIBUTION BOARDS

Horizontal & Vertical Specification IS : 13032 / IS : 8623

32

Standard make Smart Distribution Boards provides flexibility and a systematic approach to ever increasing need for effective methods of the electrical distributions in domestic, commercial and industrial application. Standard Smart distribution boards have been specially designed to meet all the technical requirements and ensure the distribution boxes blend with the decor of the place of the installation. The Smart distribution boards with their features and their range offer a compact, practical and economic solution to any electrical network in residential / commercial complexes, industries etc. having single phase or three phase connections. The Smart distribution board is not merely an enclosure but a complete system in itself comprising of ETP Copper bus bar, brass neutral link, earth link, earthing studs, and interconnection wires for effective distribution of current.

Features & Benefits


Superior aesthetics that blend well with the decor. Made of special grade CRCA sheet steel to provide strength and longer life to enclosures. Manufactured with latest technology CNC Punch and Brake presses to attain highest degree of perfection. Painted with epoxy polyster and polyster resin based powder paints with latest techniques in powder coating ensures strong, scratch resistant coatings. Current carrying parts are made of electrolytic grade of copper having high conductivity and low resistivity thereby keeping temperature rise and distribution losses very low. Appropriate sizes of DIN rails to facilitate easy and fast mounting of MCBs, RCCBs, Isolators etc. Brass neutral and earth bars of suitable cross-sectional areas are provided to facilitate connections for each outgoing terminals. Adequate number of knockout holes of various sizes are provided both at the top and the bottom. This facilitate easy installation and connection of conduits of all sizes, both for top and bottom. Detachable upper and lower end plates provided for easy and flexibility of cabling. Superior single phase bus bars provided which are completely insulated and fitted in PVC channel to avoid accidental touch. Suitable for both flush and surface mounting. Conforms to IS 13032 & IEC : 439 & 529

33

DISTRIBUTION BOARDS

RANGE
S.No. (a) (b) Type SPN TPN Configuration SPN Consumer TPN (Horizontal) Vertical Per Phase Isolation (PPI) (c) Special Extended loose Wire Three Tier Power Line 7 Segment DB Phase Selector(40&63A) Plug & Socket MCB Enclosures Application Simple, Economical & Safe distribution Simple, Economical & Safe distribution Three phase & Neutral incoming and outgoing can be only single phase Three phase and neutral incoming, outgoing can be single phase as well as multi phase DP RCCB in each phase is provided to avoid the total outage as only the phase where earth leakage fault exist, get isolated. Most flexible design Most flexible design For fault level higher then 10kA with a provision for MCCB incomer Single point distribution where per phase Isolation facility is required Used for selection of a phase in case other phase fails Used for Air conditioner and motor protection To isolate / connect electrical appliances independently

SMART DISTRIBUTION BOARDS


Smart board SPN/TPN DBs Single Door Smart trek SPN/TPN DBs Double Door Smart line TPN DBs Single Door

NEW ADDITIONAL FEATURES


Masking - (Cement & Water guard) During the construction stage the DBs can get ingressed with water & cement dust. This can spoil the decor and more importantly alter the performance parameters. Standard Smart Trek DBs come with a masking arrangement that keeps water and cement dust away.

Masking (Cement & waterguard)

Flexibility during installation Standard DBs are provided with an intermediate detachable door/plate fixed on the inner door to give flexibility of installation i.e. during installation or maintenance the entire door need not be dismantled thus saving valuable installation time. Additionally this also ensures that electrically live parts do not get exposed.

Reversible Doors The outer DB doors are reversible. While the doors come fitted on the left side these can be reversed and fitted on to the right side by the user.

Intermediate detachable door

Weather proof design All DBs are provided with perfect fitted gaskets which ensures ingress protection as per IP-42 category.

Reversible door

34

DISTRIBUTION BOARDS

SMART BOARD - SINGLE PHASE SINGLE DOOR DBs IP 40 PROTECTION


Ways 4 6 8 12 16 Cat No. DSDMSNHOSI04 DSDMSNHOSI06 DSDMSNHOSI08 DSDMSNHOSI12 DSDMSNHOSI16

Dimensions (in mm)


Ways 4 6 8 12 16 A 145 182 217 289 361 Dimensions B 135 172 207 279 351 C 75 111 147 217 291 D 225 225 225 225 225 Knock Out Dia Incoming 2 No. 26 3 No. 26 4 No. 26 6 No. 26 8 No. 26 Outgoing 2 No. 26 3 No. 26 4 No. 26 6 No. 26 8 No. 26
(fixing center)

215

165

C (fixing center) B A

10 65

35

DISTRIBUTION BOARDS

SMART LINE - THREE PHASE SINGLE DOOR DBs IP 40 PROTECTION


Ways 4 6 8 12 Cat No. DSDMTNHCSI04 DSDMTNHCSI06 DSDMTNHCSI08 DSDMTNHCSI12

Dimensions (in mm)


Ways 4 6 8 12 Dimensions A 266 336 406 546 B 256 326 396 536 C 175 245 315 455 Knock Out Dia 31 4 Nos. 6 Nos. 8 Nos. 12 Nos.

(fixing center)

390

305

C (fixing center) B A

65

36

DISTRIBUTION BOARDS

VERTICAL TYPE DBs - IP 42 PROTECTION


Ways 4 8 12 Single Door DSDMTNVOSI04 DSDMTNVOSI08 DSDMTNVOSI12 Cat No. Double Door DSDMTNVODI04 DSDMTNVODI08 DSDMTNVODI12

Dimensions (in mm)


Ways 4 6 8 12 Dimensions A 578 632.5 687 796 B 560 614.5 669 778 C 484 538.5 593 702 Knock Out Dia 26 6 No. 6 No. 6 No. 6 No. 38 1 Nos. 1 Nos. 1 Nos. 1 Nos.

Mounting hole 7.0

A C (fixing center)

270.0 (fixing center) 350.0 367.0

113.0 3.5

CONSUMER UNIT - IP 40 PROTECTION


Ways 2+4 2+8 2+12 Cat No. DSDCSNHOSI04 DSDCSNHOSI08 DSDCSNHOSI12

Dimensions (in mm)


Ways 2+4 2+8 2+12 A 217 289 361 Dimensions B 207 279 351 C 157 229 301 Knock Out Dia Incoming 4 No. 26 1 No. 38 4 Nos. 26 1 No. 38 6 Nos. 26 Outgoing 4 Nos. 26 1 No. 38 4 Nos. 26 1 No. 38 6 Nos. 26

215.0 171.5 (fixing center)

225.0

C (fixing center) B A

22.0

65.0

37

SQVE SERIES - SPN DOUBLE DOOR DISTRIBUTION BOARD


Ways 4 6 8 12 16 Cat No. DSDESHODRW04 DSDESHODRW06 DSDESHODRW08 DSDESHODRW12 DSDESHODRW16

Dimensions (in mm)


Dimensions Ways 4 6 8 12 16 A 125 151 187 269 341 B 175 211 247 319 391 C 197 232 268 340 412 D 172 166 166 176 172 Knockout holes Top Bottom Side (Each Side) (25) (31) (25) (31) 3 3 1 2 1 2 1 1 2 2 2 2 1 4 2 4 2 1 4 2 4 2 1

B Knockout holes O/G ( 25) knockout holes on each side C

222

Knockout holes I/C

38

244

84.5

SQVE SERIES - TPN DOUBLE DOOR DISTRIBUTION BOARD


Ways 4 6 8 12 Cat No. DSDETHODRW04 DSDETHODRW06 DSDETHODRW08 DSDETHODRW12

Dimensions (in mm)


Ways 4 6 8 12 A 196 268 340 479 Dimensions B C 251 272 323 344 395 416 534 555 Top 3 2 2 4 Knockout holes (31) Bottom Side (Each Side) 3 1 2 1 2 1 4 1
8 A Knockout holes O/G Knockout holes each side B C Knockout holes I/C

39

97.5

PREWIRED DISTRIBUTION BOARD - SPN SINGLE DOOR


Ways 4 6 8 12 Cat No. DSDMSHMSIW04000 DSDMSHMSIW06000 DSDMSHMSIW08000 DSDMSHMSIW12000

Dimensions (in mm)


Ways 4 6 8 12 Sheet Thickness 1.2 1.2 1.2 1.2 Dimensions A 206 278 278 345 B 129 192 192 274 C 218 290 290 360 Top 4 5 5 6 Knock out holes Side (Each Bottom Side) 4 1 5 1 5 1 6 1
295 (fixing center)

371

B (fixing center) C

65

40

372

PREWIRED DISTRIBUTION BOARD - SPN DOUBLE DOOR


Ways 4 6 8 12 Cat No. DSDMSHMDIW04000 DSDMSHMDIW06000 DSDMSHMDIW08000 DSDMSHMDIW12000

Dimensions (in mm)


Ways 4 6 8 12 Sheet Thickness 1.2 1.2 1.2 1.2 Dimensions A 206 278 278 350 B 129 201 201 274 C 223 296 296 366 Top 3 5 7 9 Knock out holes Side (Each Bottom Side) 3 1 5 1 7 1 9 1

295 (Fixing center)

394

B (fixing center) C

100

41

372

PREWIRED DISTRIBUTION BOARD - TPN SINGLE DOOR


Ways 4 6 8 12 Cat No. DSDMTHMSIW04000 DSDMTHMSIW06000 DSDMTHMSIW08000 DSDMTHMSIW12000

Dimensions (in mm)


Ways 4 6 8 12 Sheet Thickness 1.2 1.2 1.2 1.2 Dimensions A 385 423 460 605 B 318 353 389 534 C 400 437 472 618 Knock out holes Side (Each Top Bottom Side) 5 5 0 7 7 0 9 9 0 13 13 0
605 (Fixing center)

687

B (fixing center) C

65

42

672

PREWIRED DISTRIBUTION BOARD - TPN DOUBLE DOOR


Ways 4 6 8 12 Cat No. DSDMTHMDIW04000 DSDMTHMDIW06000 DSDMTHMDIW08000 DSDMTHMDIW12000

Dimensions (in mm)


Ways 4 6 8 12 Sheet Thickness 1.2 1.2 1.2 1.2
96 A 605 (Fixing center) 702

Dimensions A 389 442 460 605 B 315 349 387 534 C 410 445 482 624

Knock out holes Side (Each Top Bottom Side) 5 5 0 7 7 0 9 9 0 13 13 0

B (fixing center) C

81.0

43

675

DISTRIBUTION BOARDS

POWERLINE VERTICAL TYPE DBs - IP 42 PROTECTION


Ways 4 6 8 12 Cat No. DSDPVDIBEOTO04 DSDPVDIBEOTO06 DSDPVDIBEOTO08 DSDPVDIBEOTO12

Dimensions (in mm)


Ways 4 6 8 12 Dimensions A B 578 560 632.5 614.5 687 669 796 778 C 484 538.5 593 702 Knock Out Dia
Mounting hole 7.0

26 6 Nos. 6 Nos. 6 Nos. 6 Nos.

38 6 Nos. 1 Nos. 1 Nos. 1 Nos.

A C (fixing center)

270.0 (fixing center) 350.0 367.0

113.0 3.5

PER PHASE ISOLATION (PPI) HORIZONTAL DBS - IP 42 PROTECTION

Ways 04 06 08

Capacity of 17.8 mm module Incomer + Outgoing 4 + (6+12) 8 + (6+18) 8 + (6+24)

Cat No. DSDPTHPDRW04 DSDPTHPDRW06 DSDPTHPDRW08

Dimensions (in mm)


No. of Ways 04 06 A 323 395 Dimensions B 268 340 C 333 405 Knockout Holes (31) Top Bottom Side(Each Side) 6 8 6 8 2 2
720 B

88 C A E 375 450 480

No. of Ways 08

A 557

Dimensions B 482

C 587

Knockout Holes (31) Top Bottom Side(Each Side) 11 11 2

44

10 103

C B C

DISTRIBUTION BOARDS

PER PHASE ISOLATION (PPI) VERTICAL DBs - IP 42 PROTECTION

Ways

2 + 12

Capacity of 17.8 mm module Incomer + Outgoing 8 + (6 + 36)

Cat No.

DSDPTVPDRW12

Dimensions (in mm)


No. of Ways 2 + 12 Dimensions A B C 395 320 405 Knockout Holes (31) Top Bottom Side (Each Side) 7 7 6
C A 3 103 11 B

375

450

PHASE SELECTOR (HORIZONTAL) DBS - 4 QUADRANT DESIGN (With Rotary Switches & Wires)
No. of Ways 4 4 6 6 8 8 Rating 40A 63A 40A 63A 40A 63A Cat. No. (DD) Horizontal DSDSCHDRZ04040 DSDSCHDRZ04063 DSDSCHDRZ06040 DSDSCHDRZ06063 DSDSCHDRZ08040 DSDSCHDRZ08063

With With With With With With

eight eight eight eight eight eight

way way way way way way

incomer incomer incomer incomer incomer incomer

slot slot slot slot slot slot

PHASE SELECTOR DBS (Without Rotary Switches & Wires)


No. of Ways 4 6 8 Regal Grey Cat. No. (DD) DSDSCHDRZ04000 DSDSCHDRZ06000 DSDSCHDRZ08000

45

460

DISTRIBUTION BOARDS

PHASE SELECTOR (VERTICAL) DBs DOUBLE DOOR


No. of Ways 4 4 6 6 8 8 Rating 40A 63 A 40 A 63 A 40 A 63 A Cat. No. Double Door DSDSNVDRZ04040 DSDSNVDRZ04063 DSDSNVDRZ06040 DSDSNVDRZ06063 DSDSNVDRZ08040 DSDSNVDRZ08063

Dimensions (in mm)


Ways Capacity of Rating 17.8 mm module Incoming+Outgoing 8+12 40A 8+12 63A 8+18 40A 8+18 63A 8+24 40A 8+24 63A A B C Knockout Holes Top Bottom Each Side 25 20 25 20 20 9 8 9 8 3 9 8 9 8 3 9 8 9 8 3 9 8 9 8 3 9 8 9 8 3 9 8 9 8 3

595 670

4 4 6 6 8 8

333 333 405 405 405 405

323 323 395 395 395 395

248 248 320 320 320 320

A B C

7 SEGMENT DBs - IP 42 PROTECTION


Ways 4 6 8 12 Cat No. DSDMTHDDRW04 DSDMTHDDRW06 DSDMTHDDRW08 DSDMTHDDRW12

Dimensions (in mm)


Ways 4 6 8 12 A 456 562 672 888 B 320 428 536 752 C 494 602 710 926 Knock Out Holes (31) 8 8 8 12
D- 31 Knockout holes O/G D- 31 Knockout holes O/G

680

550 650

680

D- 31 Knockout holes O/G A B

550 650

D- 31 Knockout holes O/G A B

102 8

22

102 8

C 6W, 8W & 12W

22

22

11 105

680

C 4W

22

46

DISTRIBUTION BOARDS

MCB SHEET STEEL ENCLOSURES


Ways (Amp.) 1 2 3 4 Cat No. DSDESSP DSDESDP DSDESTP DSDESFP

Dimensions (in mm)


Ways 1 2 3 4 Dimensions A B 78 64 118 104 118 104 136 122 C 28 49 49 67 D 164 189 189 189 E 150 175 175 175 Knock Out Dia Incoming 1Nos. 26 1Nos. 26 1Nos. 26 1Nos. 26 Outgoing 1Nos. 26 1Nos. 26 1Nos. 26 1Nos. 26
C (fixing center) B A (KSS-1+N) Earth Terminal

107.0 (fixing center)

125.0 (fixing center)

C (fixing center) B A (KSS-2+N/ 3+N / 4+N)

53.5 63.0
(KSS-1+N / 2+N/ 3 /4+N)

MCB PLASTIC ENCLOSURES


Ways 3/4 Cat No. DSDEPDP DSDEPFP

Dimensions (in mm)


Ways 1/2 3/4 A 140 140 Dimensions B C 45 65 81 65
A

47

PLUG AND SOCKET ENCLOSURES


Rating (Amp.) 20A/SPN/DP (AC Box) 20A/TP 30A/TP Cat No. DSDPUSN020 DSDPUTN020 DSDPUTN032

Dimensions (in mm)


Rating Amps. 20 20 30 Item Code KSPS/SP KSPS/TP KSPS/TP Surface Mounting W L 133 162 123 287 123 287 Incoming 1 No. f 26 1 No. f 26 1 No. f 26 Knockout Outgoing
(fixing center) 254.0

1 No. f 26 1 No. f 26 1 No. f 26


W

63.0

Earth terminal

110.0

152.0

278.0 56.0 63.0

TP

ACCESSORIES
Neutral Bar/Earth Bar DIN Channel Bus Bar with PVC Sleeve Blanking Plate 1/2

CUSTOMIZED DBs
Prewired DB Dbs with extended loose wire box Meter Box (1 Phase & 3 Phase)

ROW TYPE DISTRIBUTION BOARDS


STANDARD make row type distribution boards are versatile in design and aesthetics. These are specially designed for domestic as well as multi-storey complexes. Keeping in view the capacity usage requirement, these are available in 1,2,3,4 and 5 rows both in 12 module and 16 module versions. The flush mounting and aesthetic look adds to the grace of interiors. These are supplied duly epoxy powder coated with shade RAL 7035 or as per specific requirement of the customers.

FEATURES
The DB can be supplied with neutral and earth bars if so required The enclosures are made of special grade CRCA steel sheet manufactured with latest CNC punch and brake presses to attain higher degree of perfection. Adequate number of knockouts at the end plates are provided for ease of wiring. Din rails are provided for snap mounting of MCBs/RCCBs. The DB is suitable for IP 40 degree of protection.

48

SPN

IP RATINGS
The IP (International Protection) rating given to an enclosure states the degree of protection it offers by means of two digits. A summary of these is shown below, for a more detaileddefition, see IEC 529 : 1989, BS EN 60529 : 1992. Protection against solid foreign objects and access to hazardous parts.The first digit covers protection against penetration by solid objects, which includes hands and tools such as screwdrivers. At the lowest of seven levels, 0, no protection is offered, either of the equipment itself from damage by intrusion or of a person contacting live or moving parts. At the highest, there shall be no entry of dust.

FIRST DIGIT

SECOND DIGIT

Protection against ingress of water. The second digit covers the degree of protection against the entry of water, on a progressive scale. for example, number 1 indicates that dripping water shall have no harmful effect, and number 6, that water projected in powerfuljets against the enclosure from any direction shall have no harmful effects.

No Protection

No Protection

Protected against solid objects up to 50 mm. e.g. accidental touch by hands

Protected against vertically falling drops of water eg. condensation

Protected against solid objects up to 12 mm e.g. fingers

Protected against direct sprays of water up to 15 from the vertical

Protected against solid objects over 2.5 mm e.g. tools and wires

Protected against sprays of water up to 60 from the vertical

Protected against solid objects over 1 mm e.g. tools, wires and small wires

Protected against after splashed from all directions -limited ingress permitted

Protected against dust -limited ingress, no harmful deposits

Protected against low pressure jets of water from all directions -limited ingress permitted

Totally protected against dust.

Protected against strong jets of water e.g. for use on ship decks -limited ingress permitted

The letter X can be used in place of the first or second digit to indicate that tests have either not been made or are not applicable.

49

CATEGORY OF DUTY
The category of duty defines the basic type of circuit and switching capability of the device, and selection should be made accordingly. Utilisation Category AC20/DC20 Typical Applications and disconnecting under AC23/DC23 AC22/DC22 Switching of mixed resistive / inductive loads, including moderate overloads. Suitable for mixed resistive / inductive loads. Devices can switch 300% of its rated current under fault conditions. Switching of highly inductive loads. Devices complying with AC23/DC23 are provided mainly as back-up to other means of switching. e.g. contacts. In the event of failure of functional devices, an AC23 / DC23 type device can safety interrupt a stalled motor current. Where devices are the only means of controlling individual motors, they should comply with the requirements of appendix A of the standard. (IEC 60947-3)

Connecting no-load.

Assumes all switching operations are carried out by other capable devices before this device is operated. AC21/DC21 Switching of resistive moderate overloads. loads including

Suitable for purely resistive type loads devices can switch 150% of its rated current under fault conditions

Ue = Rated Operational Voltage The normal line-to-line voltage of the system should not exceed (Ue)

Icu Rated Ultimate Short Circuit Breaking Capacity The calculated prospective fault current at the incoming terminals of the circuit breaker should not exceed (Icu). Exception: Using back-up protection as specified by the manufacturer.

Ui = Rated Insulation Voltage The voltage on which the dielectric properties have conventionally been based using tests at high voltage and mains frequency. It is intended to replace this value with (Uimp) Uimp = The voltage on which clearance distances are based. The value of transient peak voltage the circuit breaker can withstand from switching surges or lighting strikes imposed on the supply. e.g. Uimp = 8kV, Tested @8kV peak with 1.2/50m (ms)S impulse wave Ui = 660V Tested@ 2500V ac 50Hz

Ics Rated Current

Short-time

Withstand

The maximum level of fault current operation after which further service is assured without loss of performance.

Icw Rated Current

Short-time

Withstand

Circuit breakers of utilisation category B have a short-time delay allowing time-graded selectivity between circuit breakers in series. (Icw) is the current the circuit breaker will withstand for the maximum shorttime delay time. Preferred times are 0.05, 0.1, 0.25, 0.5 and 1.0 second.

In = Rated Current The current which the circuit breaker will carry continuously under specified conditions and on which the time / current characteristics are based.

Unless otherwise slated (In) is based on a reference ambient temperature of 30 centigrade.

50

REGIONAL BRANCH OFFICES NORTH - REGIONAL OFFICE : Delhi : QRG Towers, 2D, Sector-126, Expressway, Noida-201304 Noida : Tel: 0120-4771000, Fax: 0120-4772000 Chandigarh : Tel: 0172-4232400 -401, Fax: 0172-4232403, Dehradun : Tel: 0135-2521025, 2521552 Haryana : Tel: 91-120 2477848 / 853, Fax: 0120-2583904 Noida : Tel: 0120-3055609 / 3055610, Fax: 0120-3055611 Ludhiana : Tel: 0161-4676001 / 6024, Fax: 0161-46766007 Jammu : Tel:0191-2490424, Fax: 0191-2490405 Jaipur : Tel: 0141-3988210, Fax: 0141-2389024 Lucknow : Tel: 0522-2201032, 2200938 Kanpur : Tel: Airtel: 09935533751/52/53, 0512-2690128/129/130, Fax: 0512-2692800 EAST - REGIONAL OFFICE : Kolkata : ICC Tower, 5th Floor, 4 India Exchange Place, Kolkata-700 001 Kolkata : Tel: 033-40129851/52, Fax: 033-40127339 Bhubaneshwar : Tel: 0674-2598104, 2598105, 2598106, Fax: 0674-2598107 Guwahati : Tel: 0361-2134521, 2458923, Fax: 0361-2460355 Siliguri : Tel: 0353-2525907-3290402 (RIM) Jamshedpur : Tel: 0657-6542492, 09234369436 Patna : Tel: 0612-3244218, 2655519, Telefax: 0612-2655518 WEST - REGIONAL OFFICE : Mumbai : 302, Boston House, 3rd Floor Suren Road, CTS No. 260/261, Andheri (E), Mumbai-400 093 Mumbai : Tel: 022-67298600-603 Ahmedabad : Tel: 079-40061111, 40060738-740, Fax: 079-40060741 Indore : Tel: 0731-2572340-41, 4009998 (Airtel), Fax: 0731-2551626 Rajkot : Tel: 0281 3013289 / 3013290 Nagpur : Tel: 0712-2224132, 2222692, 2222029 Pune : Tel: 020-64016413/14 Raipur : Tel: 0771-4243400 / 01, Telefax: 0771-4243402 Surat : Telefax: 0261-2350137 SOUTH - REGIONAL OFFICE : Chennai : Block 1, A & D Wing, Shakthi Towers, 7th Floor, 766, Annna Salai, Chennai-600 002 Chennai : Tel: 044-28526941-44, Fax: 044-28524326 Bangalore : Tel: 080-39882100, 30515801 / 2 / 3 /4, Fax: 080-30515804 Coimbatore : Telefax: 0422-2305767, 2306199, 2305199 Hyderabad : Tel: 040-27533372, 27533355, 27533632, 66320407/0408/6401/6402, Fax: 040-27533211 Kochi : Tel: 0484-4099000, 2393165, 2393068, Fax: 0484-2393170 Vishakapatnam : Tel: 0891-6514339, Fax: 0891-2522547

REPRESENTATIVE OFFICES Goa Solapur Gwalior Jabalpur Hubli Davanagere Gulbarga Mysore Trichy Kathmandu Sambalpur

Jalandhar

Bhopal

Calicut

Madurai

Trivandrum

Corporate Office: QRG Towers, 2D, Sector -126, Expressway, Noida - 201 304 (UP), Ph. +91-120-4771000, India E-mail: standard.ho@sel.co.in Consumer Care No.: 1800 11 0303 (Toll Free), 011-41 66 0303 (Landline), 1800 103 1313 (All connections) Registered Office: 1/7, Ram Kishore Road, Civil Lines, Delhi - 110054 Visit us at : www.sel.co.in For International Trade Enquires, please E-mail to: export.sel@sel.co.in