NS-120 and NS-480 Technical Pre-Sales

October, 2008

2008 EMC Corporation. All rights reserved.

Welcome to the Celerra NS-120 and NS-480 Technical Pre-Sales. The AUDIO portion of this course is supplemental to the material and is not a replacement for the student notes accompanying this course. EMC recommends downloading the Student Resource Guide from the Supporting Materials tab, and reading the notes in their entirety. These materials may not be copied without EMC's written consent. EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. THE INFORMATION IN THIS PUBLICATION IS PROVIDED AS IS. EMC CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. EMC is a registered trademark, and Celerra is a trademark of EMC Corporation. All other trademarks used herein are the property of their respective owners.

NS-120 and NS-480 Technical Pre-Sales

-1

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

Course Overview
Course Description
This course provides an introduction to the NS-120 and NS-480. It includes a description of the platforms and their components, product positioning, as well as collateral, services and warranty information.

Intended Audience
This course is intended for audiences with a Celerra background who are responsible for positioning the NS-120 and NS-480 offerings.

EMC believes the information in this publication is accurate as of its publication date and is based on PreGA product information. The information is subject to change without notice. For the most current information, see the EMC Support Matrix and the product release notes in Powerlink.
2008 EMC Corporation. All rights reserved. NS-120 and NS-480 Technical Pre-Sales - 2

This course provides an introduction to the NS-120 and NS-480. It includes a description of the platforms and their components, product positioning, as well as collateral, services and warranty information. This course is intended for audiences with a Celerra background who are responsible for positioning the NS-120 and NS-480 offerings. EMC believes the information in this publication is accurate as of its publication date and is based on PreGA product information. The information is subject to change without notice. For the most current information, see the EMC Support Matrix and the product release notes in Powerlink.

NS-120 and NS-480 Technical Pre-Sales

-2

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

Course Objectives
Upon completion of this course, you will be able to:
Describe the NS-120 and NS-480 platforms and their benefit to the customer Technically position the NS-120 and NS-480 Explain the architectural components Discuss planning and implementation considerations Explain the ordering procedures, services, and collateral available for the NS-120 and NS-480

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 3

These are the objectives for this course. Please take a moment to read them.

NS-120 and NS-480 Technical Pre-Sales

-3

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

NS-120 and NS-480 Overview


Upon completion of this module, you will be able to:
Describe whats new in the Celerra Unified Platform Explain the target audience and customer benefits Describe positioning the NS-120 and NS-480 Compare & contrast the NS-120 and NS-480 platforms Highlight competitive offerings

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 4

These are the objectives for this module. Please take a moment to read them.

NS-120 and NS-480 Technical Pre-Sales

-4

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

Whats New
Celerra Unified Storage with CX4 Backend
NS-120: Celerra NS20 replacement NS-480: Celerra NS40 replacement NAS, iSCSI, FC Option, MPFS

Available in Q4

CSA provisioning wizard


Simplify initial provisioning

Celerra NS-120 120 Drives 1 or 2 Blades

Celerra NS-480 480 Drives* 2 Blades**

Celerra NS-480 * FC hosts can access 240 drives ** 2 or 4 Blades in Q1

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 5

The NS-120 is the new low-end unified storage platform to replace the NS20. The NS-480 is the new mid-range unified storage platform to replace the NS40. The NS-120 and NS-480 are a technology refresh with the new CLARiiON CX4 storage array on the backend. The new integrated CLARiiON CX4 back end storage offers advanced functionality like dual protocol capabilities, hot pluggable IO modules for online expansion, and the ability to support future technologies. This technology also provides fiber channel and iSCSI ports for use by Celerra MPFS. The new platforms will offer increased storage capacity (up to 120 drives for NS-120 and up to 480 drives for NS-480). The new systems allow for a wide variety of connectivity options (NAS, iSCSI, FC and MPFS ) based on the customers needs. A provisioning wizard is now an integral part of the Celerra Startup Assistant (CSA). Where CSA provides a simple, guided installation and system test process, a provisioning wizard adds a guided process for initial configuration of the Celerra for production usage.

NS-120 and NS-480 Technical Pre-Sales

-5

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

Key Benefits and Target Audience


Key Benefits
Storage/file server consolidation via existing IP infrastructure and skills Extends consolidation benefits to stranded servers Control costs, improve backups, increase availability Option to leverage CLARiiON CX4 Fibre Channel
Ethernet iSCSI SAN

iSCSI SAN

Fibre Channel

NAS
Ethernet File Sharing Fibre Channel SAN

Target Customer Profile


NS-120: 10 to 20 Servers, 4 to 32 TB NS-480: 20 to 50 Servers, 16 to 64 TB VMware, Oracle Microsoft Exchange, SQL Server Windows or Unix/Linux file servers
2008 EMC Corporation. All rights reserved.

Integrated NAS and iSCSI

Integrated FC for bandwidth intensive applications Celerra NS-120, NS-480

Celerra NS-120, NS-480 brings CX4 advanced functionality to Fibre Channel attached hosts
NS-120 and NS-480 Technical Pre-Sales - 6

The NS-120 and NS-480 are ideal for engagements where the environment requires file server and a storage consolidation solution. The unified storage (NAS, iSCSI, FC and MPFS ) capabilities provide a single platform for file server consolidation (NAS) and storage consolidation (iSCSI, Fiber Channel, MPFS). Consolidating with a Celerra unified storage means customers can control costs, improve backups, and increase availability. A typical customer deployment may consist of VMware servers, Exchange, SQL, or Oracle applications. The option to leverage the CLARiiON CX4 backend array provides additional flexibility and investment protection for deployment options.

NS-120 and NS-480 Technical Pre-Sales

-6

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

Positioning with AX4, NX4, NS and CX4


Product
CLARiiON AX4

Requirements
Lowest price point Single protocol is required (iSCSI or FC) RepliStor is a viable option for iSCSI remote replication.

Celerra NX4

Unified Storage (NAS, iSCSI, FC) Low price point Channel friendly pricing Advanced IP-based replication Competing with NetApp FAS2020

Celerra NS-120/NS-480

Unified Storage (NAS, iSCSI, FC, MPFS) More capacity and connectivity Advanced IP-based replication Competing with NetApp FAS2050/3140

CLARiiON CX4

All other requirements Emphasis on technology innovations

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 7

The CLARiiON AX4 price point is lower than the NX4 and is suitable for environments where only a single protocol is required (iSCSI or Fiber Channel). The NX4 is ideal for price-sensitive engagements where the environment requires file server and a storage consolidation solution. The unified storage (NAS, iSCSI and FC) capabilities provide a single platform for file server consolidation (NAS) and storage consolidation (iSCSI, Fiber Channel). The NS-120 or NS-480 should be positioned when the scalable capacity requirements exceed what the NX4 can offer. Also, these platforms should be positioned where more fiber channel SAN ports are required over what can be accommodated by the NX4. For all other requirements (i.e. synchronous replication), position the CLARiiON CX4, emphasizing the CX4 technology innovations and business impacts.

NS-120 and NS-480 Technical Pre-Sales

-7

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

EMC Celerra Family (Q4)


Integrated
Dedicated storage Easy to deploy Simple to manage Fibre Channel Option

Gateway
Shared storage Add NAS, iSCSI to Fibre Channel SAN Highest storage usage Consolidated management

NX4
Availability Number of Blades Connectivity
Failover 1 or 2 NAS, iSCSI, FC option CLARiiON 16 TB/ 32 TB

NS-120 NS20
Failover 1 or 2 NAS, iSCSI, FC option, MPFS CLARiiON 32 TB/ 64 TB

NS-480 NS40
Failover 1 or 2* NAS, iSCSI, FC option, MPFS CLARiiON 64 TB/ 128 TB

NS80
Advanced clustering 24 NAS, iSCSI, FC option CLARiiON 128 TB/ 384 TB

NS40G
Failover 1 or 2 NAS, iSCSI, MPFS CLARiiON, Symmetrix 64 TB/ 128 TB

NS80G
Advanced clustering 24 NAS, iSCSI, MPFS CLARiiON, Symmetrix 128 TB/ 384 TB

NSX
Advanced clustering 48 NAS, iSCSI, MPFS CLARiiON, Symmetrix 128 TB/ 896 TB

Storage Maximum usable IP storage capacity (blade/system)

* NS-480 supports dual blade only


2008 EMC Corporation. All rights reserved. NS-120 and NS-480 Technical Pre-Sales - 8

This table shows the Celerra family in Q4 2008. Note that the NS-480 provides support for only two Data Movers (blades) in Q4 2008.

NS-120 and NS-480 Technical Pre-Sales

-8

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

NS-120 and NS-480 Comparison


NS-120
# of Data Movers Connectivity Storage Max usable IP capacity/system Max drive count (NAS) FC option (system) Drive types Backend Loops Max # of Expansion DAEs Min rack space Customer Installable

NS-480
2 or *4 NAS, iSCSI, FC, MPFS CX4-480 *192TB 480 8 FC ports FC, SATA 4 31 9U Yes

1 or 2 NAS, iSCSI, FC, MPFS CX4-120 64TB 120 8 FC ports FC, SATA 1 7 8U Yes

*NS-480 with 4 Data Movers and 192TB usable capacity will be available in Q12009
2008 EMC Corporation. All rights reserved. NS-120 and NS-480 Technical Pre-Sales - 9

Shown is a platform comparison between the NS-120 and NS-480. Note that the NS-480 will be available with four Data Movers and a maximum usable capacity of 192TBs in Q1 of 2009. At GA, the NS-480 with 2 active Data Movers can support a usable capacity of 128TBs. The maximum footprint of the NS-120 is 29Us and for the NS-480 is 102Us.

NS-120 and NS-480 Technical Pre-Sales

-9

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

NS20 and NS-120 Comparison


NS20
# of Data Movers Connectivity Storage Max usable IP capacity/system Max drive count (NAS) FC option (system) Drive types Backend Loops Max # of Expansion DAEs Min rack space Customer Installable

NS-120
1 or 2 NAS, iSCSI, FC, MPFS CX4-120 64TB 120 8 FC ports FC, SATA 1 7 8U Yes

1 or 2 NAS, iSCSI, FC, *MPFS CX3-10 64TB 90 8 FC ports FC, SATA 1 5 7U Yes

*NS20 w/MPFS is only supported with the FC option


2008 EMC Corporation. All rights reserved. NS-120 and NS-480 Technical Pre-Sales - 10

Shown is a platform comparison between the NS20 and NS-120. Note that two additional DAEs are available in the NS-120 for a maximum drive count of 120.

NS-120 and NS-480 Technical Pre-Sales

- 10

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

NS40 and NS-480 Comparison


NS40
# of Data Movers Connectivity Storage Max usable IP capacity/system Max drive count (NAS) FC option (system) Drive types Backend Loops Max # of Expansion DAEs Min rack space Customer Installable

NS-480
2 or *4 NAS, iSCSI, FC, MPFS CX4-480 *192TB 480 8 FC ports FC, SATA 4 31 9U Yes

1 or 2 NAS, iSCSI, FC, MPFS CX3-40 128TB 120 4 FC ports FC, SATA 2 7 7U No

*NS-480 with 4 Data Movers and 192TB usable capacity will be available in Q12009
2008 EMC Corporation. All rights reserved. NS-120 and NS-480 Technical Pre-Sales - 11

Shown is a platform comparison between the NS40 and NS-480. Additional backend loops provide the ability to add more expansion DAEs, which allows for a greater drive count. Also, a key distinction between the NS40 and NS-480 is that the NS-480 will be customer installable.

NS-120 and NS-480 Technical Pre-Sales

- 11

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

Competitive Comparison
NetApp (IBM)
YES NO NO NO NO YES

Functionality
Unified Storage 5-9s Availability Advanced functionality at no extra cost Flash drives Multi-path File System Simple to deploy and use

EMC
YES YES YES YES YES YES

HP
NO NO NO NO NO YES

Equal Logic
NO NO YES NO NO YES

LeftHand
NO NO YES NO NO YES

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 12

This table shows how the NS-120 and NS-480 compare with competitors offerings. Within the unified storage space, the NS-120 will primarily compete against the NetApp FAS2050 and FAS2050A and the NS-480 will primarily compete against the FAS3140 and FAS3170.

NS-120 and NS-480 Technical Pre-Sales

- 12

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

NS-120 and NS-480 Architecture


Upon completion of this module, you will be able to: Describe the NS-120 and NS-480 components
Control Station Data Movers I/O Modules SPE

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 13

These are the objectives for this module. Please take a moment to read them.

NS-120 and NS-480 Technical Pre-Sales

- 13

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

Control Station (Front View)

Highlights of new Control Station:


2.0GHz Celeron (Conroe) CPU w/ 800MHz FSB, 0.5MB Cache, & 2GB memory One SATA disk drive (80GB min) No Floppy Drive No reset button 1u form factor 120/240VAC auto-sensing power supply, minimum 300w power supply, with a 120v power cord. One CD/DVD drive Requires DART 5.6 Maintenance Release with RedHat Linux 4.0

Front View Cut-Out

USB port

Support for only the new Control Station


2008 EMC Corporation. All rights reserved. NS-120 and NS-480 Technical Pre-Sales - 14

The Control Station manages the system and maintains the user data separate from the management data. Listed are the new Control Station specifications. With this Control Station model, there is no reset button and there is no floppy drive. NAS (DART) installations will be bootable from the CD. Older model Control Stations are not supported, even in the event of a Control Station failure. The NS-120 and NS-480 do not support dual Control Stations.

System Status LED (not used)

System Power LED Hard Drive Activity LED Onboard NIC1 LED Onboard NIC2 LED

Power Button

NS-120 and NS-480 Technical Pre-Sales

- 14

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

Control Station (Rear View)


Eth3
Connects to the customer network. Customer assigns an IP address during setup. Celerra GUI is accessed via this interface.

RX232 serial ports


console for install & maintenance

RX232 serial ports


Modem for dial-in/out to EMC

Eth1
Not used for NS-120 & NS-480.

Eth0
Connects to the primary DM management network. Configured with the IP 128.221.252.100 (default)

Eth2
Connects to the secondary DM management network. Configured with the IP 128.221.253.100 (default)

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 15

Shown is the rear view of the Control Station. One RS232 serial port is for console access and the other RS232 serial port is for the modem connection. Four Ethernet ports are available. Note that port Eth1 will not be used with the NS-120 and NS-480 platforms. It may be used for other future platforms to connect to a peer CS. Eth0 and Eth2 are used for the communication with the Data Movers (2 different subnets).

NS-120 and NS-480 Technical Pre-Sales

- 15

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

Data Mover (Rear View)


Same as current NS20/NS40
Dual Intel 2.8 Ghz LV-Nocona Processors (P4) 4GB Memory. 800 MHz Front-Side-Bus Dual Management Network Interfaces Integrated Management Switch Two serial ports for DART console and debugging 4-Port copper Gigabit Ethernet NAS Personality 2-Port copper plus 2-Port optical NAS Personality (NS-480 only) 4 Integrated (Agilent QX4) 4 Gb Fibre ports
Mge1 (to mgmt module A on SPA (or server_4 if applicable)

Mge1 (to mgmt module B on SPB (or server_5 if applicable)

Server_3 network ports

Server_2 network ports

Mge0 (to CS)

BE0 (to SPA slot A0 port 3)

BE1 (to SPB slot B0 port 3)

Mge0 (to CS)

BE0 (to SPA slot A0 port 2)

BE1 (to SPB slot B0 port 2)

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 16

The Data Movers in the NS-120 and NS-480 are the same as the Data Movers in the NS20 and NS40. The NS-120 can have 1 or 2 Data Movers and NS-480 has 2 Data Movers. In Q1 of 2009 the NS-480 will be available with 2 or 4 Data Movers.

NS-120 and NS-480 Technical Pre-Sales

- 16

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

CX4 SPE (Front View)


CPU Module LEDs CPU Module LEDs

Power Supply / Blower (A0)

Power Supply / Blower (A1)

Power Supply / Blower (B0)

Power Supply / Blower (B1)

SPA

SPB

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 17

The front view of the Storage Processor Enclosure (SPE) is shown. The front of the SPE allows access to the power supply/blower modules and the CPU Modules. The CX4-120 and CX4-480 feature common 400 Watt 2U Power Supplies. The power supplies are available in a standard AC input or a -48V DC input for the Telco industry. They include integrated dual counter rotating fans. There are two power supplies per Storage Processor, therefore four power supplies per system. Both power supplies for a storage processor must be removed before the CPU Module can be removed.

NS-120 and NS-480 Technical Pre-Sales

- 17

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

CX4 SPE (Rear View)


Power Input B Power Input A

Mgmt Module B

Mgmt Module A

Slot B3

Slot B4

Slot B1

Slot B2

Slot A0

Slot A1

Slot B0

Slot A2

SPE for NS-120I shown here

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 18

The rear view of the CX4-120 and CX4-480 Storage Processor Enclosure (SPE) is shown. The rear of the SPE allows access to the I/O Modules and the Management Modules. The CX4-120 and CX4-480 SPE provides slots for one Management Module and five I/O Modules per Storage Processor. The Management Modules are required for all models. The minimum and maximum number of I/O Modules is model dependent.

Slot A3

Slot A4

NS-120 and NS-480 Technical Pre-Sales

- 18

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

I/O Modules
Management Module iSCSI I/O Module
iSCSI Port 1 (1Gb/s)

GbE Service LAN

GbE Management LAN (internal network)

iSCSI Port 0 (1Gb/s)

FC I/O Module

SPS Port COM2 Fiber Port 3 (4Gb/s) Fiber Port 2 (4Gb/s) NMI Button Service Port COM1 Fiber Port 1 (4Gb/s)

Fiber Port 0 (4Gb/s)

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 19

Shown is the management module and the I/O modules. On the management module, the management LAN IP address is used for the internal network of the NS-120 and NS-480. A serial interface is provided to monitor the Standby Power Supply (SPS) and a serial interface is provided for service. The I/O Modules are a common component across the entire CX4 family of arrays. The modules are available in two versions, Fiber Channel and iSCSI. The FC I/O Module contains four ports and the iSCSI I/O Module contains two ports. The NS-120 requires one FC I/O Module per SP installed in slot 0 and NS-480 requires two FC I/O Modules per SP installed in slot 0 and slot 1. Additional required and optional I/O Modules are model dependent.

NS-120 and NS-480 Technical Pre-Sales

- 19

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

NS-120 and NS-480 Planning, and Implementation Considerations


Upon completion of this module, you will be able to: Distinguish between the base, FC, and iSCSI options
NS-120, NS-120F, and NS-120I NS-480, NS-480F, and NS-480I

Explain CSA and CPW Describe the supported and unsupported HW and SW Describe upgrade paths

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 20

These are the objectives for this module. Please take a moment to read them.

NS-120 and NS-480 Technical Pre-Sales

- 20

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

Models
NS Model Useable I/O ports/SP Backend I/O Base Host or MPFS Array Modules (internal MPFS over
FC) NS-120 NS-120F NS-120I NS-480 NS-480F NS-480I
CX4-120 CX4-120 CX4-120 CX4-480 CX4-480 CX4-480 1xFC 2xFC 1xFC, 2xiSCSI 2xFC 3xFC 2xFC, 3xiSCSI 3 (2xDM and 1xBE) 3 (2xDM and 1xBE) 3 (2xDM and 1xBE) 8 (4xDM and 4xBE) 8 (4xDM and 4xBE) 8 (4xDM and 4xBE)

FC Enabled
NO YES NO NO YES NO

over FC
4 4 -

iSCSI
4 6

The I/O module options for the backend SPs are different for each model

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 21

Each model has a specific SPE hardware configuration. The SPE I/O modules combined with the backend array platform determine the NS model. This table shows the I/O module configurations and port assignment on the backend.

NS-120 and NS-480 Technical Pre-Sales

- 21

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

NS-120
NS-120 backend I/O module configuration
Zero FC ports for non-Celerra hosts

Captive array, no FC, iSCSI or MPFS attached hosts


Celerra Manager for backend storage implementation and administration One 1U Control Station One 1U Data Mover Enclosure with one or two Data Movers One 2U CX4-120 SPE with two SPs One 1U SPS enclosure with one or two SPS One 3U OS DAE holding a maximum of 15 disks

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 22

Three backend I/O module configurations are available for NS-120. In each configuration, the first I/O module will have one port reserved for backend DAE connection and two ports for Data Mover connections. The fourth port will be unpopulated and is not used for non-Celerra hosts. Ports 2 and 3 on the FC I/O module are reserved for Data Mover connections. If the expected Data Mover is not present, the port will not be used. The NS-120 is considered the Base Integrated model with each SP containing one 4 port 4Gb/s optical FC I/O Module.

NS-120 and NS-480 Technical Pre-Sales

- 22

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

NS-120F
NS-120F backend I/O module configuration

This is the FC enabled Option


Adds FC ports on each SP in backend array for direct, MPFS or SAN attached hosts One 4 port FC I/O Module added to each SP (8x 4 Gb/s FC ports per system) FC Option Enablement License (FCOEL) for sharing CX4 array with nonCelerra hosts Supports Clariion SW and host SW

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 23

The NS-120F is the FC Enabled Option with each SP containing two 4 port 4Gb/s optical FC I/O Modules. The second FC I/O module will have all 4 ports in each SP available for direct-attach or SAN-attach MPFS or non-Celerra FC hosts. Array management is accomplished via Navisphere Manager.

NS-120 and NS-480 Technical Pre-Sales

- 23

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

NS-120I
NS-120I backend I/O module configuration

This is the iSCSI enabled option for MPFS


Four iSCSI modules added to backend array for iSCSI-connected MPFS hosts MPFS iSCSI option includes HW with MPFS license

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 24

The NS-120I is the iSCSI enabled option for MPFS model with each SP containing one 4-port 4Gb/s optical FC I/O Modules plus two, 2-port 1Gb/s iSCSI I/O Modules. The two iSCSI I/O modules will have all 4 ports per SP available for iSCSI-connected MPFS hosts. The iSCSI ports are for MPFS hosts only (i.e no iSCSI host via native backend).

NS-120 and NS-480 Technical Pre-Sales

- 24

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

NS-480
NS-480 backend I/O module configuration
Zero FC ports for non-Celerra or MPFS hosts

Base integrated NS-480 HW configuration consists of


One 1U Control Station One 1U Data Mover Enclosures with two Data Movers The 4 Data Mover capability with 2 DME available Q109 for all configurations One 2U CX4-480 SPE with two SPs Each SP comprises 2, 4 port 4Gb/s optical FC I/O Modules One 1U SPS enclosure with two SPS One 3U OS DAEs holding a maximum of 15 disks
NS-120 and NS-480 Technical Pre-Sales - 25

2008 EMC Corporation. All rights reserved.

Three backend I/O module configurations are available for NS-480. In each configuration, two FC I/O modules per SP are used for the system. The I/O modules will have four ports reserved for backend DAE connections and four ports for Data Mover connections. No ports are used for non-Celerra hosts. If the expected Data Mover is not present, the port will not be used. The NS-480 contains two 4 port 4Gb/s optical FC I/O Modules per SP.

NS-120 and NS-480 Technical Pre-Sales

- 25

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

NS-480F
NS-480F backend I/O module configuration
NS-480F supports a maximum of 240 drives for non-Celerra host attach

This is the FC enabled option


Adds FC ports on each SP in backend array for direct, MPFS or SAN attached hosts One 4 port FC I/O Module added to each SP (8x 4 Gb/s FC ports per system) FC Option Enablement License (FCOEL) for sharing array with non-Celerra hosts

MirrorView over FC is supported on systems ordered with FC Enabled Option and the FC hardware factory installed
2008 EMC Corporation. All rights reserved. NS-120 and NS-480 Technical Pre-Sales - 26

The NS-480F is the FC enabled option with each SP containing three 4 port 4Gb/s optical FC I/O Modules. The third FC I/O module has all 4 ports in each SP available for direct attach or SAN-attach MPFS or non-Celerra FC hosts. The MirrorView over FC is supported on systems ordered with the FC Enabled Option when the FC hardware is factory installed.

NS-120 and NS-480 Technical Pre-Sales

- 26

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

NS-480I
NS-480I backend I/O module configuration

NS-480I is the iSCSI enabled option for MPFS


2 FC I/O Modules zero ports for non-Celerra hosts 3 iSCSI I/O Modules - all 6 ports available for iSCSI-connected MPFS hosts

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 27

The NS-480I is configured with two, 4 port FC I/O modules and three, 2 port iSCSI modules. The iSCSI ports are for MPFS hosts only.

NS-120 and NS-480 Technical Pre-Sales

- 27

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

Integrated NAS and iSCSI


iSCSI Servers and NAS clients

NS-120 and NS-480 Zero FC ports for non-Celerra hosts No FC or iSCSI I/O modules for MPFS

Ethernet

iSCSI connectivity for block I/O via LAN NAS connectivity via NFS and CIFS

NS-120 & NS-480 Unified Storage

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 28

A common integration example would be application servers (SQL, Exchange, or Oracle) requiring block storage where access via iSCSI is acceptable. NAS for Home Directories, shared data, general purpose files via CIFS, NFS, and/or FTP access. The NS solution can control hardware growth/sprawl, provide business continuance, and offer rich features/functionality to grow with the Data Center.

NS-120 and NS-480 Technical Pre-Sales

- 28

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

Fiber Channel Option


NS-120F and NS-480F
iSCSI Servers and NAS clients

FC ports for MPFS and native block access Navisphere Manager for backend management
MPFS

Ethernet

iSCSI connectivity for block access via LAN


Fibre Channel SAN

NAS connectivity via NFS and CIFS


Integrated FC for bandwidth intensive applications (optional)

NS-120 & NS-480 Unified Storage

Fibre Channel
2008 EMC Corporation. All rights reserved. NS-120 and NS-480 Technical Pre-Sales - 29

Here we can build from the previous example to include the fiber channel option that can accommodate application servers (SQL, Exchange, or Oracle) requiring greater bandwidth to access storage. MPFS can also use the fiber channel structure for any applications requiring a higher degree of performance. iSCSI can still be used for application servers requiring block storage where access via iSCSI is acceptable and NAS connectivity can still be used for Home Directories, shared data, general purpose files via CIFS, NFS, and/or FTP access.

NS-120 and NS-480 Technical Pre-Sales

- 29

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

iSCSI Enabled Option for MPFS


iSCSI Servers and NAS clients

NS-120I and NS-480I iSCSI ports for MPFS Allow connection to up to 6 (4 on NS-120I) Linux/Windows/Unix directattached iSCSI MPFS hosts (with HA)
iSCSI SAN

Ethernet

Or allows up to 250 iSCSI-SANattached iSCSI MPFS hosts (with HA) connect via ethernet switches iSCSI connectivity for block access via LAN NAS connectivity via NFS and CIFS
NS-120 and NS-480 Technical Pre-Sales - 30

NS-120 & NS-480 Unified Storage Integrated MPFS via iSCSI for high performance implementations

MPFS via iSCSI

2008 EMC Corporation. All rights reserved.

Another option that is viable for high performance implementation is MPFS via iSCSI. Here the servers can connect directly (or via network) to the backend storage array via iSCSI and receive all the meta data via the existing LAN. As with the previous example, iSCSI can still be used for application servers requiring block storage where access via iSCSI over the LAN is acceptable and NAS connectivity can still be used for Home Directories, shared data, general purpose files via CIFS, NFS, and/or FTP access. MPFS now supports RHEL 5 u2 and SLES 10 sp2 hosts.

NS-120 and NS-480 Technical Pre-Sales

- 30

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

CSA Celerra Startup Assistant


NS-120 or NS-480 platforms
New cable check script New cable check help pages for troubleshooting cabling issues New provisioning wizard

Initial-configuration tool - configures the NAS systems postinstall at the customer site (not a management tool)
Configures Control Stations external network interface Runs health checks and assists in correcting cabling errors Can setup public IP addresses for SPA and SPB Provision storage Setup Data Movers interface and create test CIFS share / NFS Export / iSCSI LUNs Configures ConnectHome Email Transport service Registers the system
NS-120 and NS-480 Technical Pre-Sales - 31

2008 EMC Corporation. All rights reserved.

The Celerra Startup Assistant (CSA) is a Windows application (installer is in the Apps and Tools CD). The CSA is an initial-configuration tool, not a management tool, and is used to setup the NAS systems post-install at the customer site. For the NS-120 or NS-480 platforms, the CSA has a new cable check script and cable check help pages for troubleshooting cabling issues. The CSA can setup the Control Stations external network interface (like Init Wizard), run the health checks, assist in correcting cabling errors, setup public IP addresses for SPA and SPB, setup the Data Movers interface and create test CIFS share / NFS Export / iSCSI LUNs. The CSA can configure the ConnectHome Email Transport service by specifying the email server in CSA initialization screen. Users provide the recipient email addresses to configure and enable the Email User service as part of the same CSA installation. The serial console will be disabled and NAS services will not start until cable verification is complete.

NS-120 and NS-480 Technical Pre-Sales

- 31

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

CSA Provisioning Wizard


Simplify initial provisioning Configure storage Implement best practices Validate operations

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 32

The CSA provisioning wizard is an integral part of the Celerra Startup Assistant (CSA). The express method simplifies storage provisioning by configuring the system for the maximum usable capacity. The custom method allows for greater configuration flexibility.

NS-120 and NS-480 Technical Pre-Sales

- 32

32

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

Supported/Unsupported HW and SW

Supported
MPFS via iSCSI & FC RAID1/0, RAID5, RAID6 FC drives - 146GB 15K, 300GB 15K, 300 and 400GB 10K, 450GB 15K rpm SATA II drives - 1000GB 7200 and 1000GB 5400rpm *CX4 software and layered applications

Unsupported
Gateway configuration Dual Control Station UPS for Data Movers TimeFinder and SRDF SATA vault drives in NS-480

*Only MirrorView/S is supported with the Celerra *CX4 applications are supported on the NS-120F and NS-480F

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 33

The NS-120 and NS-480 supports MPFS via fiber and iSCSI connectivity. RAID1/0, RAID5, RAID6 with a variety of drive technologies are supported. The hot spare rule remains a minimum of one hot spare for every thirty FC drives and one hot spare for every thirty SATA drives. The CLARiiON software and layered applications supported when the FC option is purchased are:
Full Navisphere License and media kit Navi Analyzer NQM (Navisphere Quality of Service Manager) MirrorView/Sync (for Celerra w/RPQ, Windows, and UNIX hosts) MirrorView/Async (for Windows and UNIX hosts) SnapView Full (for Windows and UNIX hosts) SAN Copy (for Windows and UNIX hosts) Virtual Provisioning (for non-Celerra hosts) Host-based SW: Powerpath, Recoverpoint, Replistor and Replication Mgr MirrorView/Sync is the only layered application supported with the Celerra.

The NS-120 and NS-480 does not provide support for dual Control Stations. No gateway configuration is supported and therefore, no support is available for Symmetrix dependent features such as TimeFinder and SRDF. A UPS is provided for the backend array, not for the Celerra Data Movers. Although SATA vault drives are supported in the NS-120, there is no support for SATA vault drives in the NS-480.
NS-120 and NS-480 Technical Pre-Sales

- 33

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

Software Changes
AccessLogix is enabled User LUNs will be created on RG0 for all configurations NS-480 backend CLARiiON read cache size is increased to 512 MB To re-install an existing system, cleanup the backend using the command nas_raid s cleanup On NS-120/NS-120I/NS-480/NS-480I systems
Use Celerra Tools for storage management Use setup_clariion2 tool to create raid groups and LUNs on unconfigured disks

NS-120F and NS-480F systems


Use Navisphere Manager for storage management
2008 EMC Corporation. All rights reserved. NS-120 and NS-480 Technical Pre-Sales - 34

AccessLogix is enabled for all configurations on the NS-120 and NS-480. The Celerra Storage Group (Celerra_emcnas_i0) will be created and the Control LUNs 0-5 and user LUNs will be created and added to the Storage Group. Celerra Raid Group 0 (RG0) will be fully provisioned for user LUNs on all configurations. Sharing of RG0 with other non-Celerra hosts is not a best practice. On the NS-480 backend (CX4-480), the default CLARiiON read cache size has increased from 32 MB to 512 MB. To re-install an existing system, nas_raid s cleanup can be used to cleanup the backend. On the non-FC platforms (NS-120/NS-120I/NS-480/NS-480I) Celerra Tools (Celerra Manager, setup_clariion2 etc) should be used for storage management (creating Raid Groups, LUNs etc). The setup_clariion2 tool can be used to create raid groups and LUNs on un-configured disks. It will also add the new LUNs to the Celerra Storage Group. For the NS-120F and NS-480F systems, CLARiiON Tools (Navisphere Manager) should be used for storage management (similar to a Gateway configuration).

NS-120 and NS-480 Technical Pre-Sales

- 34

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

Proxy ARP
NS-120 and NS-480 offer public access to CLARiiON SPs CLARiiON is on the private network, but with public IPs The CSA collects two public IP addresses, one for each SP The SP IP addresses must be on same subnet as the CS IP address The Proxy ARP configuration running as part of the CSA process changes the IP addresses of the SPs to the public IP addresses Command to setup/modify the IP address
/nasmcd/sbin/clariion_mgmt

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 35

Like NS20/NS40 systems, NS-120 and NS-480 will offer public access to CLARiiON SPs. Proxy ARP provides access to the SPs although the SPs are on the NS internal network. To service the array, public IP addresses are needed for the SPs for all configurations to allow the use of the Navisphere Service Taskbar (NST). Also, public IP access for the SPs is needed when managing the array via Navisphere Manager (FC option).

NS-120 and NS-480 Technical Pre-Sales

- 35

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

Hardware Upgrades
Upgrades available at GA date
Platform
NS-120, 1DM NS-120, 1 SPS NS-120 NS-480

Upgrade
NS-120, 2DM NS-120, 2 SPS Expansion DAEs (up to 7) and drives Expansion DAEs (up to 31) and drives

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 36

The following non-disruptive HW upgrades for an installed NS-120/NS-120F/NS-120I system will be supported at product GA: Expansion to 120 FC and/or SATA drives via the addition of up to seven, fifteen drive DAEs Add second SPS Addition of second Data Mover The following non-disruptive HW upgrades for an installed NS-480/NS-480F/NS-480I system will be supported at product GA: Expansion to 480 FC and/or SATA drives via addition of up to 31, fifteen drive DAEs Upgrading from an NS-120 to an NS120F or NS-120I or upgrading from a NS-480 to a NS-480F or NS-480I is currently not available. If customers require the F or I options they need to be purchased at the initial time of sale.

NS-120 and NS-480 Technical Pre-Sales

- 36

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

Collateral, Services, and Ordering


Upon completion of this module, you will be able to:
Describe warranty and service options List the CRU and FRU support Explain the NST support Describe the service offerings Access links to collateral material and information List ordering information

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 37

These are the objectives for this module. Please take a moment to read them.

NS-120 and NS-480 Technical Pre-Sales

- 37

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

Warranty and Maintenance


Two tier
Enhanced Warranty - 3 year
5x9 next business day onsite support 7x24 remote technical support and troubleshooting Customer required to perform CRU

Premium Warranty - upgrade


All service activities 7x24 onsite support with 4 hour response 7x24 remote technical support and troubleshooting Root cause analysis EMC provide CRU replacement

Installation services are not included with the purchase of the product or with the purchase of a warranty upgrade
Professional services available for both installation and implementation services
2008 EMC Corporation. All rights reserved. NS-120 and NS-480 Technical Pre-Sales - 38

A three year enhanced level warranty is included with the purchase of the NS-120 or NS-480. The enhanced warranty provides 7x24 remote support and 5x9 next business day onsite and customer replacement of designated parts. Customers can upgrade to the premium warranty. The premium warranty provides 7x24 onsite support with four hour response as well as 7x24 remote support. The systems are customer installable. Installation services, commonly referred to as rack and stack, are not included with the purchase of the product or with the purchase of a warranty upgrade.

NS-120 and NS-480 Technical Pre-Sales

- 38

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

CRU and FRU Support


CRU NAS Blades SFPs Management Module AC power supply/blower modules SPS Disk drives FRU Control Station CPU Modules Memory FC I/O Modules iSCSI I/O Modules I/O Carrier Disk Array Enclosure (DAE) Link Controller Cards (LCC) Power Supply (DAE) Blade Enclosure (DME) Storage Processor Enclosure (SPE)
2008 EMC Corporation. All rights reserved. NS-120 and NS-480 Technical Pre-Sales - 39

Shown above are the hardware components that are customer replaceable and field replaceable. The NST Wizard is needed in order to make the FC and iSCSI I/O Modules into CRUs. While this is in development it will not be available at product GA. Celerra Tools on Powerlink will carry the CRU/FRU procedures. The Control Station is assisted CRU; the customers performs the replacement with the remote help of CE/Field Specialist. Control Station fault isolation document is available on Celerra Tools to help decide when a CS replacement is needed.

NS-120 and NS-480 Technical Pre-Sales

- 39

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

NST Support
NST Function
SLIC zWizard Register Storage System Install DAE Install Disk Prepare for Installation Install Software Help Verify Storage System Replace Disk Disk Firmware Hotfix Post activity SYR

NS-120 and NS-480


Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes No

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 40

The table shown above depicts the available Navisphere Service Taskbar functions for the NS-120 and NS-480. With version R28, customers can perform the Flare code upgrade using the Software Assistant on NST. However, NAS code upgrades will need to be performed with the assistance of an EMC (or Partner) service professional.

NS-120 and NS-480 Technical Pre-Sales

- 40

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

NS-120 and NS-480 Service Offerings


Quick Start services
EMC Implementation for Celerra CIFS QuickStart (PS-BAS-IMCIFS) EMC Implementation for Celerra NFS QuickStart (PS-BAS-IMNFS) EMC Implementation for Celerra iSCSI QuickStart (PS-BAS-IMiSCSI)

Installation services
EMC installation for Celerra QuickStart (PS-BAS-INGUI)
Not included in the implementation quick start

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 41

Implementation quick starts are available for CIFS, NFS, and iSCSI. Installation is not included in the implementation quick start services. A separate installation service is available if required for the customer.

NS-120 and NS-480 Technical Pre-Sales

- 41

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

Access to Collateral Material and Information


Support options: Powerlink, Services Support Services Support Options Maintenance and Celerra

MPFS use cases: https://studioe.emc.com Support Matrices: Powerlink e-Lab (not available until external launch) Announcement Resources: Powerlink, Products Hardware/Platforms Celerra Family Celerra documentation and software: Powerlink, Product and Diagnostic Tools Celerra Tools Support

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 42

This slide refers to some of the areas where information about the NS-120 and NS-480 are located.

NS-120 and NS-480 Technical Pre-Sales

- 42

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

Ordering Information

Correct model must be ordered at time of sale


No upgrades are available from a base model to a fiber channel enabled option or iSCSI for MPFS enabled option

NS-120 and NS-480 models will be available to order in the November 2008 update of Direct Express Support options will be orderable in the November update of Direct Express The Fiber Channel option is chargeable MPFS requires the purchase of an MPFS license
2008 EMC Corporation. All rights reserved. NS-120 and NS-480 Technical Pre-Sales - 43

If a customer needs the FC or iSCSI enabled options they cannot purchase the base configuration and upgrade in the field. In other words, if customers require the F or I options they need to be purchased at the initial time of sale. NS-120 and NS-480 models as well as their support options will be available to order in the November update of Direct Express. The Fiber Channel option is chargeable and the MPFS option requires the purchase of the MPFS license.

NS-120 and NS-480 Technical Pre-Sales

- 43

Copyright 2008 EMC Corporation. Do not Copy - All Rights Reserved.

Course Summary
Key points covered in this course:
The NS-120 and NS-480 are the backend technology refresh for the NS20 and NS40 and offer increased capacity and advanced CX4 functionality and performance. The NS-120 and NS-480 each have three specific platforms determined by the backend array model and the I/O port configuration. The NS-480 will be available with four Data Movers and increased capacity in Q12009.

2008 EMC Corporation. All rights reserved.

NS-120 and NS-480 Technical Pre-Sales - 44

These are the key points covered in this training. Please take a moment to review them. This concludes the training. In order to receive credit for this course, please proceed to the Course Completion slide to update your transcript and access the assessment.