Selection Guide ........................................... 882 NRA Series .................................................. 883 NRBM Series .............................................. 893 NRC Series ................................................. 900 General Instructions .................................... 909 Internal Circuit Overview ............................ 909
Switches & Pilot Lights Display Lights Relays & Sockets Timers Terminal Blocks
For more information on this product family, visit our website. Additional resources include:
New and updated product information Downloadable software demos & upgrades Part conguration tool & cross reference Online stock check & ordering IDEC eld sales & distributor search Online literature request Downloadable manuals & CAD drawings Manufacturers suggested retail price list Product training schedule & locations Advertising & trade show schedules Press releases & FAQs
Circuit Breakers
www.idec.com/circuitbreaker
Table of Contents Automation & Sensing - Pg. 1 Safety - Pg. 315 Switching & Controls - Pg. 439 Index - Pg. 911
Circuit Breakers
NRC 900
Appearance
Display Lights
Slide, lever 1, 2
Protection Method Internal Circuits Auxiliary Contact Alarm Contact Inertia Delay Time Delay Curves Rated Voltage Rated Tripping Currents 0.3A, 0.5A, 0.75A 1A, 2A, 3A, 5A, 7.5A, 10A, 15A, 20A, 25A, 30A 1,000A, 250V AC (50/60Hz), 65V DC Lever: UL, c-UL, VDE Rocker: UL Optional (250V AC, 5A; 50V DC, 1A) Optional (250V AC, 5A; 50V DC, 1A) Optional (for resistance to high inrush) 2 types for DC; 3 types for AC
Optional (250V AC, 5A; 50V DC, 1A) Optional (250V AC, 5A; 50V DC, 1A) Optional (for resistance to high inrush) 2 types for DC; 3 types for AC 250V AC, 50/60Hz, 65V DC 1A, 2A, 3A, 5A, 7.5A, 10A, 15A, 20A, 25A, 30A, 40A, 50A 1,000A, 250V AC (50/60Hz), 65V DC 0.3A, 0.5A, 0.75A, 1A, 2A, 3A, 5A, 7.5A, 10A, 15A, 20A, 25A, 30A 2,500A, 220V AC (50/60Hz, 1-pole) 1,500A, 220V AC (50/60Hz, 2-pole) 1,500A, 65V DC (1-pole) 1,000A, 65V DC (2-pole) UL, CSA 2 types for DC; 2 types for AC
Timers
1. For dimensions, see end of each section. 2. UL recognized, applicable standard: UL1077, Supplementary Protectors. 3. Not suitable for branch circuit protection.
Terminal Blocks
Circuit Breakers
www.idec.com 882 Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Circuit Breakers
NRA Series
NRA Series
Features:
Available in 4 different styles Excellent overload and short circuit protection Small size and high-efciency Life expectancy of over 10,000 operations UL1077 recognized Supplementary Protectors VDE certied to EN60934
File No. E68029 License #116381
NRAS
NRAN
NRAR
Display Lights
Rocker
Specications
Protection Method Internal Circuit Number of Poles Rated Voltage Rated Tripping Currents Rated Interrupting Capacity Auxiliary Contact Alarm Contact Reference Temperature Operating Temperature Insulation Resistance Dielectric Strength Vibration Resistance Shock Resistance Life Expectancy Termination Illumination Voltage (NRAR illuminated units) Electromagnetic tripping Series current trip NRAS and NRAN: 1, 2, 3 NRAR: 1 250V AC, 50/60Hz, 65V DC 0.3A, 0.5A, 0.75A 1A, 2A, 3A, 5A, 7.5A, 10A, 15A, 20A, 25A, 30A 250V AC, 50/60Hz, 1,000A 65V DC, 1,000A SPDT microswitch: 250V AC, 5A (resistive load), 50V DC, 1A (resistive load) SPDT microswitch: 250V AC, 5A (resistive load), 50V DC, 1A (resistive load) 25C 40 to +85C (avoid freezing) 100M (measured with 500V megger) Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute 100N (approximately 10G) (10 to 100Hz) 1,000N (approximately 100G) Minimum 10,000 cycles (at 6 operations per minute) Main terminal: Quick-connect receptacle 0.250 (accepts M3.5 screw terminal adapter) Auxiliary contact, alarm contact: Quick-connect receptacle 0.080 Neon: 120, 240V AC, 50/60Hz
Circuit Breakers
USA: - Fax: 208.368.0415 - 888-317-IDEC Canada: Web: www.clrwtr.com - Email: info@clrwtr.com 883 Clearwater Tech - Phone: 800.894.0412 800-262-IDEC
NRA Series
Part Numbering Guide
Switches & Pilot Lights
Circuit Breakers
NRA series part numbers are composed of up to 8 part number codes. When ordering an NRA series part, select one code from each category. Example: NRAR 1 1 11 -F - 30A -AA -1
NRAR
j Model
1
k Poles
1
l Internal Circuit
11
m Auxiliary and Alarm Contacts
30A
o Rated Current
AA
1
q Pilot Light*
n Inertia Delay
Display Lights
Lever (round cutout) j Model Lever (rectangular cutout) Rocker 1-pole k No. of Poles l Internal Circuit 2-pole 3-pole Series current trip Without With auxiliary contact With alarm contact n Inertia Delay o Rated Current p Time Delay Curve q Pilot Light* Without inertia delay With inertia delay Rated current (current trip) AC curves DC curves With neon light 120V AC (50/60Hz) With neon light 240V AC (50/60Hz)
1. For NRA series accessories, see page 886. 2. For NRA series time delay curves, see page 888. 3. For NRA series dimensions, see page 890. 4. Not suitable for branch circuit protection. 5. UL recognized, applicable standard: UL1077, Supplementary Protectors.
Circuit Breakers
Terminal Blocks
www.idec.com 884 Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Circuit Breakers
Information About Circuit Breakers
NRA Series
16,000
Display Lights
14,000
Percent of Rated Current
x 100%
Timers
Notes Multi-Pole
Multi-pole types such as 2- or 3-pole should be assembled by IDEC. Because of their characteristics, 1-pole breakers cannot be combined to provide multi-pole units.
USA: - Fax: 208.368.0415 - 888-317-IDEC Canada: Web: www.clrwtr.com - Email: info@clrwtr.com 885 Clearwater Tech - Phone: 800.894.0412 800-262-IDEC
NRA Series
Accessories
Switches & Pilot Lights
Circuit Breakers
Remarks
Colored Cap
Colored caps t onto NRAS circuit breakers for color coding circuits and improving the appearance of the panel.
Display Lights
NRT
For use on main terminals only. Includes M3.5 clamp screw. For dimensions see page 892.
Remarks
63 mm
NRAN
For 3-pole For 2-pole (Black plastic plate)
3-pole
NR33
Use of a ush plate makes snap-in mount possible for NRAN, and NRAR circuit breakers (tightening screws not necessary). Multiple units can mount in a single panel cut-out.
For 1-pole
1-pole
Timers
Mounting Clip
1. Furnished with a hold-down spring. 2. Applicable only for series trip units up to 20 amps. 3. Not applicable for NRAR lighted series. 4. Not for use with circuit breakers incorporating auxiliary
or alarm contacts.
Terminal Blocks
For dimensions of NRA series accessories and panel cut-out layouts, see drawings starting on page 891.
Circuit Breakers
www.idec.com 886 Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Circuit Breakers
Internal Circuits and Terminal Arrangements: NRAS and NRAN Series
NRA Series
LINE
LINE
LINE
NC NO C
NO NC
Display Lights
LOAD
LOAD
LOAD
LOAD
LOAD
(Lead wire A) (Lead wire B)
LOAD
(Lead wire A) (Lead wire B)
A White Black
B White Black
(~)
C NC NO LINE
(~)
LINE
NO NC
Dashed lines represent NRAR illuminated rocker units. Lead wires for neon pilot light as shown above.
Timers
LINE
Terminal Blocks
Time Delay Curves (numerical equivalent) Overcurrent Time Delay Characteristics in Seconds (at 25C)
Percent of Rated Current Curve AC (50/60Hz) AA BA MA AD MD 100% No trip No trip No trip No trip No trip 125% 10 120 0.75 10 60 900 10 130 35 400 150% 6 45 0.45 3.5 30 260 6 55 20 200 200% 2.2 15 0.22 1.3 9 70 2.6 20 7 60 400% 0.3 2 0.045 0.22 1.5 8 0.5 3.5 1.3 8 600% 0.05 0.55 0.012 0.12 0.18 2.5 0.12 1.4 0.2 3 800% 0.007 0.13 0.005 0.06 0.009 0.25 0.008 0.1 0.01 0.25 1000% 0.005 0.04 0.004 0.03 0.006 0.08 0.005 0.05 0.006 0.08
Circuit Breakers
DC
1. All values above are in seconds. 2. Data in this table is equivalent to information presented in the time delay curves shown on page 888.
USA: - Fax: 208.368.0415 - 888-317-IDEC Canada: Web: www.clrwtr.com - Email: info@clrwtr.com 887 Clearwater Tech - Phone: 800.894.0412 800-262-IDEC
NRA Series
Time Delay Curves NRA Series
Switches & Pilot Lights
1000 100 10 1 0.1 1000
Circuit Breakers
Time in sec
Display Lights
0.01
100 150 300 400 500 600 700 800 900 1000 125 200 Current (percent load of the rated current) 1000 100
Time in sec
100 150 300 400 500 600 700 800 900 1000 125 200 Current (percent load of the rated current)
Time in sec
10 1 0.1
0.01
Timers
100 150 300 400 500 600 700 800 900 1000 125 200 Current (percent load of the rated current)
Terminal Blocks
Time in sec
Circuit Breakers
100 150 300 400 500 600 700 800 900 1000 125 200 Current (percent load of the rated current)
Time in sec
100 150 300 400 500 600 700 800 900 1000 125 200 Current (percent load of the rated current)
www.idec.com 888 Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Circuit Breakers
Resistance and Impedance Characteristics
NRA Series
Coil Data
DC Resistance Rated Current Curves AD, MD 9.67 3.24 1.45 0.90 0.21 0.09 0.036 0.017 0.012 0.0066 0.0048 0.0043 0.0036 AC Impedance (50/60Hz) Curves AA, BA, MA 9.82 3.36 1.49 0.92 0.21 0.092 0.036 0.018 0.012 0.0068 0.0048 0.0041
Rated Current (A)
100 0.01 0.001 0.01 100
10
0.1
Display Lights
0.1
10
100
Impedance ()
0.0043
10
Curves AD and MD
0.1
Resistance ()
Curves AA, BA, MA, AD, and MD At the minimum tripping current (125% current)
Timers
100 80 60 40
-40
-30
-20
-10
10
20 25
30
40
50
60
70
80
90
Terminal Blocks
Circuit Breakers
USA: - Fax: 208.368.0415 - 888-317-IDEC Canada: Web: www.clrwtr.com - Email: info@clrwtr.com 889 Clearwater Tech - Phone: 800.894.0412 800-262-IDEC
NRA Series
Dimensions
Switches & Pilot Lights
Circuit Breakers
NRAS
1-pole
2-M3 Approx. 60
Tab terminal #250 (6.4W 0.8t) Tab terminal #110 2-M3 mounting screw (2.8W 0.5t)
LINE
16.6 8.2
NO
50.6 42.2
40
30.8
LOAD
19.1
Display Lights
40 49.5 53.6
NRAS1111 NRAS1111F
NRAS1121 NRAS1121F
2-pole
4-M3
NO NC
3-pole
6-M3
NO C NC NC
NO
NC
19.1 38.2
NRAS2111 NRAS2111F
NRAS2121 NRAS2121F
NRAS3111 NRAS3111F
NO
OFF
OFF
OFF
OFF
OFF
NC
OFF
NO
NC
NRAS3121 NRAS3121F
NRAN
1-pole
2-M3 Approx. 60
Tab terminal #250 (6.4W 0.8t) Tab terminal #110 2-M3 mounting screw (2.8W 0.5t)
LINE
16.6 8.2
NO
52 42.2 31.5
40
Timers
LOAD
19.1
4.5 16.5
41 50.5 54.6
NRAN1111 NRAN1111F
NRAN1121 NRAN1121F
2-pole
4-M3
NO NC
3-pole
6-M3
NO C NC NC
NO
Terminal Blocks
19.1 38.2
NRAS2111 NRAS2111F
NRAN2121 NRAN2121F
19.1
19.1 57.3
NRAN3111 NRAN3111F
NO
NC
OFF
OFF
OFF
OFF
OFF
NC
OFF
NO
NC
NRAN3121 NRAN3121F
NRAR
Tab terminal #250 (Indicator terminal)
LOAD LOAD
Indicator wire
Circuit Breakers
52 42.2 31.5
9.2 17.3
NP
NP
8.2 16.6 40
40
ON OFF
NO NC
LINE
LINE
56 65.5 70.5
56 65.5 69.6
www.idec.com 890 Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Circuit Breakers
Panel Cut-Outs
NRA Series
NRAS Series
4 Mounting hole
NRAR, NRAN
4 Mounting hole (9.8) 19.1
55.5 0.25
19.1
16+0.3 0
42.2
42.2
19.6 38.7
26.7
19.1
19.1
2-pole
5.1
1-pole
32
5.1
Display Lights
Installation Angle: Circuit breakers are designed to operate on a vertical surface. The mounting angle should not exceed a vertical plane by more than 10.
Maximum Mounting Distance Model NRAS A 3.02 (77.5mm) B 3.57 (91.5mm) Dimensions (mm) Mounting to Panel Surface
Mounting on a panel surface
19.1 mm 20.2 mm
Timers
DIN rail
NRAN
3.02 (77.5mm)
3.57 (91.5mm)
NRAR
3.38 (86.7mm)
3.93 (100.7mm)
9mm
USA: - Fax: 208.368.0415 - 888-317-IDEC Canada: Web: www.clrwtr.com - Email: info@clrwtr.com 891 Clearwater Tech - Phone: 800.894.0412 800-262-IDEC
NRA Series
Accessory Dimensions
Switches & Pilot Lights
Circuit Breakers
Display Lights
A B C
F
1.4 (35mm) 1.14 (29mm) 0.78 (23mm) 1.2 (31mm) 0.41 (10.5mm) 0.11 (3mm) 2 (51mm) 0.47 (12mm) 0.16 (4mm)
D E F
G H K
Circuit Breakers
Terminal Blocks
Timers
www.idec.com 892 Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Circuit Breakers
NRBM Series
NRBM Series
NRBM circuit breakers are the largest in rated current (1A to 50A) among the IDEC circuit breakers series. These small sized, high-efciency breakers offer a variety of protection characteristics that can be widely employed for semiconductors, relay circuits, heater circuits, transformers, and solenoids.
Display Lights
General Specications
Protection Method Internal Circuit Number of Poles Rated Voltage Rated Tripping Currents Rated Interrupting Capacity Auxiliary Contacts / Alarm Contact Reference Temperature Ambient Operating Temperature Insulation Resistance Dielectric Strength Vibration Resistance Shock Resistance Life Expectancy Terminal Style Weight Electromagnetic tripping Series current trip 1, 2, 3 250V AC, 50/60Hz, 65V DC Current trip: 1A, 2A, 3A, 5A, 7.5A, 10A, 15A, 20A, 25A, 30A, 40A, 50A 250V AC, 50/60Hz, 1,000A 65V DC, 1,000A SPDT microswitch 250V AC, 5A (resistive load) 50V DC, 1 A (resistive load) 25C 40 to +85C (avoid freezing) 100M (measured with 500V megger)
Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute 100N (approximately 10G), 10 to 55Hz 1,000N (approximately 100G) 10,000 operations minimum (at 6 operations per minute) Main terminal: M5 stud Auxiliary contact/ alarm contact: Quick-connect tab 0.110 terminal 1-pole/100g 2-pole/200g 3-pole/300g
Terminal Blocks
Circuit Breakers
USA: - Fax: 208.368.0415 - 888-317-IDEC Canada: Web: www.clrwtr.com - Email: info@clrwtr.com 893 Clearwater Tech - Phone: 800.894.0412 800-262-IDEC
NRBM Series
Part Numbering Guide
Switches & Pilot Lights
Circuit Breakers
NRBM series part numbers are composed of 6 part number codes. When ordering an NRBM series part, select one code from each category. Example: NRBM 1 1 11 F-30A-AA
NRBM
1
j Poles
1
k Internal Circuit
11
l Auxiliary and Alarm Contacts
30A
n Rated Current
AA
o Time Delay Curve
m Inertia Delay
Display Lights
1-pole j No. of Poles k Internal Circuit l Auxiliary and Alarm Contacts 2-pole 3-pole Series current trip Without With auxiliary contact With alarm contact Without inertia delay With inertia delay Rated current (current trip) AC curves DC curves
1. For NRBM series time delay curves, see page 897. 2. For NRBM series dimensions, see page 899. 3. Not suitable for branch circuit protection. 4. UL recognized, applicable standard: UL1077, Supplementary Protectors.
Circuit Breakers
Terminal Blocks
Timers
www.idec.com 894 Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Circuit Breakers
Information About Circuit Breakers
NRBM Series
16,000
Display Lights
14,000
Percent of Rated Current
x 100%
Timers
Notes Multi-Pole
Multi-pole types such as 2- or 3-pole should be assembled by IDEC. Because of their characteristics, 1-pole breakers cannot be combined to provide multi-pole units. All multi-pole units are simultaneous break/simultaneous make, with levers mechanically interlocked.
USA: - Fax: 208.368.0415 - 888-317-IDEC Canada: Web: www.clrwtr.com - Email: info@clrwtr.com 895 Clearwater Tech - Phone: 800.894.0412 800-262-IDEC
NRBM Series
Internal Circuits and Terminal Arrangements
Switches & Pilot Lights
Circuit Breakers
LINE
LINE NC NO
LINE NO NC
Display Lights
Time Delay Curves (numerical equivalent) Overcurrent Time Delay Characteristics in Seconds (at 25C)
Percent of Rated Current Curve AC (50/60Hz) AA BA MA AD MD 100% No trip No trip No trip No trip No trip 125% 15 120 0.75 10 70 900 10 130 35 400 150% 8 45 0.45 3.5 30 260 6 55 20 180 200% 3 15 0.22 1.3 10 70 2.6 20 8 60 400% 0.48 2.5 0.045 0.22 1.8 11 0.5 3.5 1.6 10 600% 0.06 0.8 0.012 0.12 0.5 4 0.14 1.4 0.6 4.5 800% 0.007 0.13 0.005 0.06 0.009 1.1 0.008 0.7 0.01 2 1000% 0.005 0.04 0.004 0.03 0.006 0.2 0.005 0.35 0.007 0.5
Timers
DC
1. All values above are in seconds. 2. Data in this table is equivalent to information presented in the time delay curves shown on page 897.
Circuit Breakers
Terminal Blocks
www.idec.com 896 Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Circuit Breakers
AC Time Delay Curves
1000
NRBM Series
1000
100
100
Time in sec
10
10
Time in sec
0.1
0.1
0.01
0.01
Display Lights
300
400
500
600
700
800
900
1000
300
400
500
600
700
800
900
1000
100
10
Time in sec
0.1
0.01
300
400
500
600
700
800
900
1000
Timers
100
100
10
10
Time in sec
Time in sec
0.1
0.1
0.01
0.01
Circuit Breakers
300
400
500
600
700
800
900
1000
300
400
500
600
700
800
900
1000
USA: - Fax: 208.368.0415 - 888-317-IDEC Canada: Web: www.clrwtr.com - Email: info@clrwtr.com 897 Clearwater Tech - Phone: 800.894.0412 800-262-IDEC
NRBM Series
Resistance and Impedance Characteristics
Switches & Pilot Lights
Circuit Breakers
Coil Data
Rated Current DC Resistance Curves AD, MD 1A 2A 3A 5A 7.5A 10A 15A 20A 25A 30A 40A 50A 1 0.227 0.091 0.035 0.015 0.0088 0.005 0.003 0.0023 0.0019 0.0018 0.0014 AC Impedance (50/60Hz) Curves AA, BA, MA 1.1 0.245 0.11 0.039 0.018 0.0124 0.0065 0.0047 0.0032 0.0031 0.002 0.0016
Curves AD and MD
10
0.1
Display Lights
0.01 0.0001
0.001
0.01
0.1
10
100
Resistance ()
100
10
0.1
Impedance ()
The internal resistance or impedance of a circuit breaker tends to be larger for a smaller rated current. Therefore, when circuit breakers of a small rated current are used, voltage drop should be taken into consideration. Internal resistance also varies with time delay curves, even at the same rated current. This should also be considered during installation.
Timers
Circuit Breakers
Terminal Blocks
www.idec.com 898 Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Circuit Breakers
Dimensions: NRBM Series
NRBM Series
2-M3 screw
19.1
19.1
2-M3 screws
10.0
(2.8W 0.5t)
60
NRBM
1-pole 2-pole
3.5 20.5
47.5 63.5
16.0
3-pole
49.2
Display Lights
26.15
20.95
52.3
35.5
1-pole 2-pole
3-pole
USA: - Fax: 208.368.0415 - 888-317-IDEC Canada: Web: www.clrwtr.com - Email: info@clrwtr.com 899 Clearwater Tech - Phone: 800.894.0412 800-262-IDEC
Circuit Breakers
NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits, transformers, solenoid valves, and semiconductors.
Display Lights
Specications
Protection Method Internal Circuit Number of Poles Rated Voltage Rated Tripping Currents Rated Interrupting Capacity Auxiliary Contact Reference Temperature Operating Temperature Insulation Resistance Electromagnetic tripping Series current trip 1, 2 250V AC (50/60Hz), 65V DC 0.3A, 0.5A, 1A, 2A, 3A, 5A, 7A, 10A, 15A, 20A, 30A 2,500A, 250V AC, 50/60Hz (2-pole: 1,500A) SPDT contact output 250V AC 3A (resistive load) 65V DC 1A (resistive load)) 40C 10 to +60C (avoid freezing) 100M (500V megger) Between the live part and the ground, between terminals of different poles, between terminals of the same pole, and between main circuit and auxiliary contact: 2,000V AC, 1 minute 100N (approximately 10G) (10 to 55Hz) 500N (approximately 50G) 10,000 operations minimum Main terminal: M4 screw (20A maximum) M5 screw (30A model) Auxiliary terminal: M3.5 screw 1-pole: 115g, 2-pole: 230g
Dielectric Strength Vibration Resistance Shock Resistance Life Terminal Style Weight (approximate)
Circuit Breakers
www.idec.com 900 Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Circuit Breakers
Part Numbering Guide
NRC Series
NRC series part numbers are composed of 5 part number codes. When ordering an NRC series part, select one code from each category. Example: NRC 1 1 1L-30A-AA
NRC
11
j Number of Poles
1
k Auxiliary Contacts
30A
AA
n Time Delay Curve
Display Lights
Slide
Leave blank
l Actuator Type
Lever
0.3A, 0.5A, 1A, 2A, 3A, 5A, 7A, 10A, 15A, 20A, 30A AC curves: AA, EA; DC curves: AD, ED
USA: - Fax: 208.368.0415 - 888-317-IDEC Canada: Web: www.clrwtr.com - Email: info@clrwtr.com 901 Clearwater Tech - Phone: 800.894.0412 800-262-IDEC
NRC Series
Accessories
Switches & Pilot Lights
Circuit Breakers
BNDN1000
Display Lights
DIN Rail End Clip Metal end clip used to prevent side-to-side movement of circuit breakers when mounted on a DIN rail. One clip required at each end.
BNL5
Panel Cut-Out Mounting Bracket Mounting bracket used to mount circuit breaker(s) in panel cut-outs. Not applicable for models with auxiliary contacts (NRC111, NRC111L, NRC211L). When mounting 2-pole models (NRC210L), use two brackets side-by-side. It is recommended to use the Fast-On Tab Terminal Adapter (below) when using this bracket.
NRC-M
Surface Mounting Bracket Used for direct surface mounting 1-pole circuit breaker models.
NRC-F
Timers
Fast-On Tab Terminal Adapter Adapter used for Fast-On wiring termination. Fast-On tab extends 0.47 (12mm) in length. Cannot be used to replace models with M5 main terminals (30A). Fast-On terminal adapter recommended when using panel cut-out mounting bracket for rear wiring.
NRC-T
Jumper Used for jumping auxiliary terminals. The rated current for jumper is 3A.
NRC-J
Terminal Blocks
Circuit Breakers
LINE
Series Trip
LOAD
NO NC LOAD
LOAD LOAD
NO NC LOAD LOAD
www.idec.com 902 Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Circuit Breakers
Time Delay Curves (numerical equivalent)
NRC Series
Display Lights
1. All values above are in seconds. 2. Data in this table is equivalent to information presented in the time delay curves below.
100
100
10
10
Time in sec
Time in sec
100 150 200 125
0.1
0.1
0.01
0.01
300
400
500
600
700
800
900
1000
300
400
500
600
700
800
900
1000
Timers
1000
1000
100
100
10
10
Time in sec
Time in sec
Terminal Blocks
0.1
0.1
0.01
0.01
300
400
500
600
700
800
900
1000
300
400
500
600
700
800
900
1000
Circuit Breakers
USA: - Fax: 208.368.0415 - 888-317-IDEC Canada: Web: www.clrwtr.com - Email: info@clrwtr.com 903 Clearwater Tech - Phone: 800.894.0412 800-262-IDEC
NRC Series
Resistance and Impedance Characteristics
Switches & Pilot Lights
Circuit Breakers
AC Impedance at 40C
100
Rated Current (A) Correction curve of impedance between terminals (at 40C)
25.6 9.04 2.33 0.548 0.261 0.099 0.048 0.026 0.013 0.0075 0.0046
10
Display Lights
0.1 0.001
0.01
0.1
Impedance ()
10
100
DC Resistance at 40C
100
Correction curve of resistance between terminals (at 40C)
10
0.1 0.001
0.01
0.1
10
100
Resistance ()
Timers
Terminal Blocks
100 80 60 40
40
20
20
40
60
80
Circuit Breakers
www.idec.com 904 Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Circuit Breakers
Dimensions: NRC Series
NRC Series
NRC110
Slide Actuator 1-Pole without Auxiliary Contacts
2-4.5 hole 12
71.2 23
NP 63.5 45.5 54
TRIP
OFF
68
Display Lights
15 25 4 64 DIN rail
NRC110L
Lever Actuator 1-Pole without Auxiliary Contacts
2-4.5 hole 12
NP 63.5 54
TRIP
OFF
45.5 64
25
10
64 DIN rail
15
68
Timers
NRC111
Slide Actuator 1-Pole with Auxiliary Contacts
2-4.5 hole 12
71.2 23
NP 63.5 45.5 54
OFF TRIP
Terminal Blocks
9.5
25
64
15 DIN rail
68
Circuit Breakers
Installation Angle: Circuit breakers are designed to operate on a vertical surface. The mounting angle should not exceed a vertical plane by more than 10.
USA: - Fax: 208.368.0415 - 888-317-IDEC Canada: Web: www.clrwtr.com - Email: info@clrwtr.com 905 Clearwater Tech - Phone: 800.894.0412 800-262-IDEC
NRC Series
Dimensions: NRC Series, continued
Switches & Pilot Lights
Circuit Breakers
NRC111L
Lever Actuator 1-Pole with Auxiliary Contacts
2-4.5 hole 12
NP 45.5 64 63.5 54
OFF TRIP
Display Lights
9.5
64 DIN rail
15
NRC210L
Lever Actuator 2-Pole without Auxiliary Contacts
Relays & Sockets
4-4.5 hole
NP 63.5
OFF
NP 54 45.5 64
OFF TRIP
50
10
64 DIN rail
15
Timers
NRC211L
Lever Actuator 2-Pole with Auxiliary Contacts
4-4.5 hole
77.2 23
NP
NP 45.5 64 54
OFF TRIP
Terminal Blocks
63.5
OFF
9.5
10 50
64 DIN rail
15
Circuit Breakers
Installation Angle: Circuit breakers are designed to operate on a vertical surface. The mounting angle should not exceed a vertical plane by more than 10.
www.idec.com 906 Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
68
68
68
Circuit Breakers
Panel Cut-Outs
NRC Series
NRC Series
Surface Mounting Hole Layout 1-Pole
2-M4 12
54
54
Display Lights
46
56
46
56
25.5
51
(1-pole type)
(2-pole type)
23.5 12 2-M4
1.2 6.5 R5
60 9
2 2 4
Timers
45.6
54
26
56
Circuit Breakers
USA: - Fax: 208.368.0415 - 888-317-IDEC Canada: Web: www.clrwtr.com - Email: info@clrwtr.com 907 Clearwater Tech - Phone: 800.894.0412 800-262-IDEC
NRC Series
Accessory Dimensions, continued
Switches & Pilot Lights
Circuit Breakers
1.4 (35mm) 1.14 (29mm) 0.78 (23mm) 1.2 (31mm) 0.41 (10.5mm) 0.11 (3mm) 2 (51mm) 0.47 (12mm) 0.16 (4mm)
D E F
Display Lights
G H K
Circuit Breakers
Terminal Blocks
Timers
www.idec.com 908 Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Circuit Breakers
Instructions: All Series
General
IDECs circuit breakers have been developed for the protection of electrical circuits and small-sized electrical equipment and provide excellent protection against overloads and short-circuits. Additionally, IDECs circuit breakers are designed to suit specic needs. Each series offers unique circuit protection characteristics and a choice of actuator styles.
Instructions
Applications
The IDEC NRA circuit breaker series features superior overload and short-circuit protection. Many combinations of protection mechanisms and internal circuit connections enable wide applications. Precision measuring instruments: electronic counters, projection instruments, oscilloscopes, industrial instrumentation, and analytic devices Industrial machinery: printers, elevators, cranes Chemical and food industry machines: vacuum devices, wrappers, centrifuges, agitators Machine tools: mill grinders, drills, presses Business machines: vending machines, beauty salon equipment, entertainment games Other: ofce equipment, air-conditioners, conveyor belts, and many more
Display Lights
Multi-Pole Assemble
Multi-pole types such as 2- or 3-pole should be assembled by IDEC. Because of their characteristics, 1-pole breakers cannot be combined to produce multi-pole units.
Timers
Terminal Blocks
Load
Series Trip This is the most common circuit breaker, providing overload and short circuit protection. It can also be used as an ON/OFF switch.
Load A
Series Trip with Auxiliary Contact Since the auxiliary contact operation is interlocked with the ON/OFF of the main contactor, circuit breaker operation can be monitored by a lamp or buzzer. This circuit breaker can also be used to control auxiliary circuits up to 250V AC/5A (resistive load).
Load B
Circuit Breakers
Load A
Load B
Series Trip with Alarm Contact Since the alarm contact is electrically independent of the main contactor, but actuates when the protective element operates. The alarm can be used with a lamp or buzzer to monitor trip operations, and can also be used for controlling alarm circuits. The contact rating is 250V AC/5A (resistive load).
USA: - Fax: 208.368.0415 - 888-317-IDEC Canada: Web: www.clrwtr.com - Email: info@clrwtr.com 909 Clearwater Tech - Phone: 800.894.0412 800-262-IDEC