IRISH AGRMENT BOARD CERTIFICATE NO. 09/0340


Insulated Render Systems Ltd., Unit 2A, Davidsons Court, Siskin Parkway East, Middlemarch Business Park, Coventry CV3 4PE. T: 0044 24 7663 7779 F: 0044 24 7630 6992 E: info@insulatedrenders.com W: www.insulatedrenders.com

Ceresit-Ceretherm External Wall Insulation Systems


Systme disolation pour murs extrieurs Wrmedmmung fr Auen-wand
NSAI Agrment (Irish Agrment Board) is designated by Government to issue European Technical Approvals. NSAI Agrment Certificates establish proof that the certified products are proper materials suitable for their intended use under Irish site conditions, and in accordance with the Building Regulations 1997 to 2008.

PRODUCT DESCRIPTION: This Certificate relates to the following CeresitCeretherm External Wall Insulation Systems: Ceresit VWS Classic (Detail Sheet 1) Ceresit-Ceretherm VWS Popular (Detail Sheet 2) Ceresit-Ceretherm VWS & WM Premium (Detail Sheet 3) Ceresit-Ceretherm VWS Express (Detail Sheet 4) These ETIC systems are each comprised of: Surface preparation of masonry or concrete substrate; Full system beads and render-only beads;

Insulation board (standard white EPS, carbonenhanced grey EPS, mineral wool); Cement-based undercoat incorporating an alkali resistant fibreglass mesh; Acrylic decorative finish coat; Decorative finish; Mechanical fixings; Weather-tight joints; Movement joints; Provision for limiting cold bridging at external wall/floor junctions in compliance with Acceptable Construction Details published by the DoEHLG; Provision for fire stopping at external compartment walls and floors.

Readers are advised to check that this Certificate has not been withdrawn or superseded by a later issue by contacting NSAI Agrment, NSAI, Santry, Dublin 9 or online at http://www.nsai.ie/modules/certificates/uploads/pdf/IAB090340.pdf

Insulated Render Systems Ltd are responsible for the design, supply and installation of the system, and for the integration of the design of the system into the building. The system is designed by Insulated Render Systems Ltd on a project specific basis in accordance with an approved design process. The installation of each system is carried out by installers who have been trained by Insulated Render Systems Ltd, and are approved by Insulated Render Systems Ltd and NSAI Agrment to install the system. This Certificate certifies compliance with the requirements of the Building Regulations 1997 to 2008. USE: The systems are for use as external insulation for refurbishment/retrofit of existing masonry or concrete buildings, up to a maximum of six storeys (18 metres) in height in purpose groups 1(a), 1(b), 1(c), 2(a), 2(b), 3, 4(a) and 4 as defined in TGD to Part B of the Building Regulations 1997 to 2008. The systems have not been assessed for use with timber frame or steel frame construction. MANUFACTURE, DESIGN AND MARKETING: The product is manufactured by: Henkel Polska Sp. z o.o., Domaniewska 41, 02 672 Warszawa, Poland. The product system is designed and marketed by: Insulated Render Systems Ltd., Unit 2A, Davidsons Court, Siskin Parkway East, Middlemarch Business Park, Coventry CV3 4PE. T: 0044 24 7663 7779 F: 0044 24 7630 6992 E: info@insulatedrenders.com W: www.insulatedrenders.com

Certificate No. 09/0340 /Ceresit-Ceretherm External Wall Insulation Systems

Part One /

Certification

1.1 ASSESSMENT In the opinion of NSAI Agrment, the CeresitCeretherm ETIC Systems if used in accordance with this Certificate can meet the requirements of the Building Regulations 1997 to 2008, as indicated in Section 1.2 of this Agrment Certificate. 1.2 BUILDING REGULATIONS 1997 to 2008 REQUIREMENTS: Part D Materials and Workmanship D3 Proper Materials The Ceresit-Ceretherm ETIC Systems, as certified in this Certificate, are comprised of proper materials fit for their intended use (see Part 4 of this Certificate). D1 Materials & Workmanship The Ceresit-Ceretherm ETIC Systems, as certified in this Certificate, meet the requirements for workmanship. Part A - Structure A1 Loading The Ceresit-Ceretherm ETIC Systems once appropriately detailed, designed and constructed have adequate strength and stability to meet the requirements of this Regulation (see Part 3 of this Certificate). A2 Ground Movement The Ceresit-Ceretherm ETIC Systems can be incorporated into structures that meet this requirement (see Parts 3 and 4 of this Certificate). Part B Fire Safety B4 External Fire Spread The Ceresit-Ceretherm ETIC Systems can be incorporated into structures that meet this requirement (see Parts 3 and 4 of this Certificate). Part C Site Preparation and Resistance to Moisture C4 Resistance to Weather and Ground Moisture External walls above DPC level have adequate weather resistance in all exposures to prevent the passage of moisture from the external atmosphere into the building as specified in Part 3 of this Certificate.

Part J Heat Producing Appliances J3 Protection of Building When the Ceresit-Ceretherm ETIC Systems are used in accordance with Section 4.1 of this Certificate, wall lining, insulation and separation distances meet this requirement. Part L Conservation of Fuel and Energy L1 Conservation of Fuel and Energy The walls of the Ceresit-Ceretherm ETIC Systems can be readily designed to incorporate the required thickness of insulation to meet the Elemental Heat Loss method calculations for walls as recommended in Part L of the Building Regulations 1997 to 2008 (see Part 4 of this Certificate).

Certificate No. 09/0340 /Ceresit-Ceretherm External Wall Insulation Systems

Part Two /

Technical Specification and Control Data

2.1 PRODUCT DESCRIPTION Each of the Ceresit-Ceretherm ETIC Systems is given a detailed description in the relevant Detail Sheet. 2.2 MANUFACTURE, SUPPLY AND INSTALLATION Henkel Polska is responsible for the manufacture and supply of all components to approved specifications, in accordance with the Henkel Polska approved supplier system. Henkel Polska has appointed Insulated Render System Ltd as distribution partner in Ireland, with responsibility for: Project specific design in accordance with approved design process; Training, monitoring and review of licensed applicators in accordance with approved training and assessment procedures; Product supply; Technical support; Sales and marketing. The installation of each system is carried out by installers who have been trained by Insulated Render Systems Ltd, and are approved by Insulated Render Systems Ltd and NSAI Agrment to install the system. 2.2.1 Quality Control The Certificate holder operates a quality management system and a quality plan is in place for system manufacture, design and installation. 2.3 DELIVERY, STORAGE AND MARKING The insulation is delivered to site in packs. Each pack is marked with the manufacturers details, product identification marks and batch numbers. Insulation should be stored on a firm, clean, dry and level base, which is off the ground. The insulation should be protected from prolonged exposure to sunlight by storing opened packs under cover in dry conditions or by re-covering with opaque polythene sheeting. Care should be taken when handling the insulation boards to avoid damage and contact with solvents or bitumen products. The boards must not be exposed to ignition sources. Each container for other components, e.g. mesh cloth, primers, renders etc., bears the manufacturers and products identification marks, batch number and the NSAI Agrment logo incorporating the Certificate number. These components must be stored in accordance with

the manufacturers instructions, in dry conditions, and at the required storage temperatures. They should be used within the stated shelf life, where applicable. 2.4 INSTALLATION 2.4.1 General Installation shall be carried out by Insulated Render Systems Ltd trained applicators who have been approved by NSAI Agrment to install the system. Installation shall be in accordance with the Certificate holders instructions and the requirements of this Certificate. Insulated Render Systems Ltd prepare a bespoke site packaged for each project, including U-value calculations, requirements for materials handling and storage, method statements for installation, building details, fixing requirements, provision for impact resistance, maintenance requirements etc. This document forms part of the contract documentation for circulation to the home owner and the installer. Installers will be expected to adhere to the specification. Deviations must be approved by an Insulated Render Systems technical representative. Insulated Render Systems Ltd technical representatives will visit the site on a regular basis to ensure that work is carried out in according with the project specific site package, including the Certificate holders installation manual. Mineral fibre board and lamella should be protected from moisture prior to and during installation. If the board or lamella gets wet during or post installation, it should not be rendered until dry. It may be necessary to remove and replace any unsuitable/wet material. 2.4.2 Site Survey and Preliminary Work A pre-installation survey of the property shall be carried out and recorded to confirm suitability of substrate for application, modifications/repairs necessary, pullout resistance of proposed mechanical fixings etc. The substrate must be free of water repellents, dust, dirt, efflorescence and other harmful contaminants or materials that may interfere with the adhesive bond. Where discrepancies preventing installation of the Ceresit-Ceretherm ETIC Systems in accordance with this Certificate and the Certificate holders instructions exist, these discrepancies should be discussed with the Certificate holder and a solution implemented with the approval of the Certificate holder.

Certificate No. 09/0340 /Ceresit-Ceretherm External Wall Insulation Systems

2.4.3 Procedure Prepare substrate in accordance with the project specific site package. Refer to the site package for guidance on modifications of down pipes, soil and vent pipes, pipe extensions etc. Base beads and all full system beads are fixed as specified. Insulation and render only beads are fixed as specified in the site package. Basecoat is mixed and applied, the mesh is laid and a further application of basecoat is applied to achieve the appropriate thickness. Primer is applied prior to the application of the selected decorative render. A minimum of two mechanical fixings per board are provided in accordance with the project specific design requirements based on pullout test results. Application of the basecoat and finishes should be carried out within the permitted temperature range and should be protected from rapid drying.

All rendering should follow best practice guidelines e.g. BS 8000-10:1995 Workmanship on building sites Code of practice for plastering and rendering and IS EN 13914-1:2005 Design, preparation and application of external rendering and internal plastering External rendering. Movement joints shall be provided in accordance with the site package. At all locations where there is a risk of insulant exposure, e.g. window reveals or eaves, the system must be protected e.g. by an adequate overhang or by purpose made sub-sills, seals or flashing. Care must be taken in the detailing of the system around openings and projections. On completion of the installation, external fittings, rainwater goods etc. are fixed through the system into the structure in accordance with the Certificate holders instructions.

Figure 1: Insulation of Building Plinth

Certificate No. 09/0340 /Ceresit-Ceretherm External Wall Insulation Systems

Figure 2: Insulation of Window/Door Frame

Figure 3: Insulation of Window/Door Head

Certificate No. 09/0340 /Ceresit-Ceretherm External Wall Insulation Systems

Figure 4: Insulation of Window Sill using XPS Sill

Figure 5: Horizontal & Vertical Fire Breaks at Compartment Wall, Floor & Ceiling Junctions (Above Second Floor Level)

Certificate No. 09/0340 /Ceresit-Ceretherm External Wall Insulation Systems

Figure 6: Connection with Eaves

Figure 7: Movement Joint

Certificate No. 09/0340 /Ceresit-Ceretherm External Wall Insulation Systems

Figure 8: Additional Reinforcing at Corners of Window/Door

Figure 9: Verge Trim Detail

Certificate No. 09/0340 /Ceresit-Ceretherm External Wall Insulation Systems

Figure 10: Connection with Vent Part Three /

Design Data

3. GENERAL The system is designed by Insulated Render Systems Ltd on a project specific basis. The design will include for: a) A site survey shall be carried out and recorded. b) Preparation of substrate. c) Minimising risk of condensation in accordance with recommendations of BS 5250:2002 Code of practice for control of condensation in buildings. d) Thermal insulation provision to Part L of the Building Regulations 1997 to 2008. e) Resistance to impact and abrasion. f) Resistance to thermal stresses. g) Resistance to wind loading. h) Design of fixings to withstand design wind loadings, using a safety factor of three for mechanical fixings and a safety factor of nine for adhesive. In addition, fixings around window and door openings shall be at a maximum of 400mm centres in each board or section of board so as to provide positive and robust restraint over the life of the system. i) Design for fire resistance, fire spread and fire stopping. j) Design of a water management system to prevent ingress of water at movement joints, windows, doors, openings for services etc.

Particular attention is required to ensure that window and sill design are coordinated to achieve a fully integrated design. k) Movement joints. l) A site specific maintenance programme for inclusion in the home owners documentation. m) Durability requirements. Detailing and construction must be to a high standard to prevent the ingress of water and to achieve the design thermal performance. When designed and installed in accordance with this Certificate, the systems will satisfy the requirements of TGD to Part L of the Building Regulations. The design shall, where possible and practicable, include for the elimination of cold bridging at window and door reveals, eaves and at ground floor level. Seals to windows and doors shall be provided in accordance with the project specific site plan. Care should be taken to ensure ventilation or drainage openings obstructed. that are any not

Certificate No. 09/0340 /Ceresit-Ceretherm External Wall Insulation Systems

Part Four /

Technical Investigations

4.1 STRENGTH AND STABILITY The Ceresit-Ceretherm ETIC Systems can be designed to withstand the wind pressures (including suction) and thermal stresses in accordance with the Building Regulations 1997 to 2008. The systems, when tested in accordance with Clause 5.3.3.1 of ETAG 004 Guideline for European Technical Approval of External Thermal Insulation Composite Systems with Rendering, have adequate resistance to severe mechanical impact and abrasion where walls are exposed and have some protection, e.g. walls of private dwellings and walls of communal dwellings above ground floor level. This does not include an allowance for acts of vandalism. The design should include for preventing impact from motor vehicles or other machinery. 4.2 BEHAVIOUR IN RELATION TO FIRE The reaction to fire classification according to IS EN 13501-1:2007 Fire classification of construction products and building elements Classification using data from reaction to fire tests was B-s2,d0 for the full system including insulation board, adhesive, base coat, finishing coats and decorative coats. The mineral wool board is classed as noncombustible as per Table A8 d) of TGD to Part B of the Building Regulations 1997 to 2008. With regard to fire stopping of cavities and limitations on use of combustible materials, walls must comply with Sections B3.2, B3.3 and B4 of TGD to Part B of the Building Regulations 1997 to 2008. Stainless steel fire fixings to be provided at the rate of one per square metre when specified. The fixing design should take account of the extra duty required under fire conditions. Vertical and horizontal fire barriers shall be provided at each compartment floor and wall, including the second floor level of a three-storey single occupancy house. Firebreaks should be adhesively bonded to the substrate and mechanically fixed with stainless steel fire fixings at 300 centres. The fire barrier should be of noncombustible material, i.e. mineral fibre, be at least 100mm high, continuous and unbroken for the full perimeter of the building and for the full thickness of the insulation.

4.3 PROXIMITY OF HEAT PRODUCING APPLIANCES Combustible material must be separated from a brick or blockwork chimney by at least 200mm from a flue, or 40mm from the outer surface of the brick or blockwork chimney, in accordance with Clause 2.15 of TGD to Part J of the Building Regulations 1997 to 2008. Metal fixings in contact with combustible materials should be at least 50mm from a flue. 4.4 THERMAL INSULATION Assessments were carried out to verify that the requirements of Part L of the Building Regulations 1997 to 2008 can be achieved using the CeresitCeretherm ETIC Systems. The manufacturers declared thermal conductivity values, when tested in accordance with IS EN 12667:2001 Thermal performance of building materials and products Determination of thermal resistance by means of guarded hot plate and heat flow meter methods Products of high and medium thermal resistance are 0.038W/mK for the standard white EPS board, 0.031W/mK for the carbon-enhanced EPS board, and 0.036W/mK for the mineral wool board. These have not been assessed by NSAI Agrment. 4.5 CONDENSATION RISK Areas where there is a significant risk of interstitial condensation due to high levels of humidity should be identified during the initial site survey e.g. bathrooms and kitchens. Condensation risk analysis will be carried out by Insulation Render Systems Ltd in accordance with BS 5250:2002, and the design modified as appropriate to reduce the risk of surface condensation to acceptable levels. 4.6 MAINTENANCE Adequate provision should be made for access and maintenance over the life of the system. The system shall be inspected and maintained in accordance with the Certificate holders instructions, as detailed in the Repair and Maintenance Method Statement, which is incorporated into the Home Owners Manual. Repairs should be carried out in accordance with the Certificate holders instructions. Repairs to plumbing etc. should also be carried out as required to prevent deterioration or damage, and to protect the integrity of the system. Synthetic finishes may be subject to aesthetic deterioration due to exposure to UV light. They should be re-painted as necessary to maintain

Certificate No. 09/0340 /Ceresit-Ceretherm External Wall Insulation Systems

appearance. Care should be taken to ensure that the paint used is compatible with the original system and that the water vapour transmission or fire characteristics are not adversely affected. Sealants shall be subject to regular inspection (at least annually). They should be replaced as required and fully replaced every 18 to 20 years to maintain performance. 4.7 WEATHERTIGHTNESS When designed and detailed in accordance with this Certificate, the system will prevent moisture from the ground coming in contact with the insulation. The external render has adequate resistance to water penetration when applied in accordance with the Certificate holders instructions. Joint designs, sealant specifications and recommendations for detailing at windows and doors were assessed and are considered adequate to ensure that water penetration will not occur, assuming that regular maintenance is carried out in accordance with the Certificate holders instructions. 4.8 DURABILITY 4.8.1 Design Life An assessment of the life of the system was carried out. This included an assessment of: Design and installation controls; Proposed building heights; Render thickness and specification; Material specifications, including insulant, mesh, beading and fixings specifications; Joint design; Construction details; Maintenance requirements. The assessment indicates that the system should remain effective for at least 30 years, providing that it is designed, installed and maintained in accordance with this Certificate. Any damage to the surface finish shall be repaired immediately and regular maintenance shall be undertaken as outlined in Section 4.6 of this Certificate. 4.8.2 Aesthetic Performance As with traditional renders, the aesthetic performance of the systems, e.g. due to discolouration, soiling, staining, algal growth or lime bloom, is dependent on a range of factors such as: Type, colour and texture of surface finish; Water retaining properties of the finish; Architectural form and detailing; Building orientation/elevation; Local climate/atmospheric pollution. Adequate consideration should be given at the design stage to all of the above to ensure that the level of maintenance necessary to preserve the aesthetics of the building is acceptable.

4.9 PRACTICABILITY The practicability of construction and the adequacy of site supervision arrangements were assessed and considered adequate. The project specific designs and method statements for application, inspection and repair were reviewed. 4.10 TESTS AND ASSESSMENTS WERE CARRIED OUT TO DETERMINE THE FOLLOWING Structural strength and stability. Behaviour in relation to fire. Impact resistance. Pull-out resistance of fixings. Thermal resistance. Condensation risk. Site erection controls. Durability of components. Dimensional stability of insulants. 4.11 OTHER INVESTIGATIONS (i) Existing data on product properties in relation for fire, toxicity, environmental impact and the effect on mechanical strength/stability and durability were assessed. (ii) The manufacturing process was examined including the methods adopted for quality control, and details were obtained of the quality and composition of the materials used. (iii) Special building details (e.g. ground level, window and door openings and movement joints) were assessed and approved for use in conjunction with this Certificate. (iv) Site visits were conducted to assess the practicability of installation the history of performance in use of the product.

Certificate No. 09/0340 /Ceresit-Ceretherm External Wall Insulation Systems

Part Five / Conditions

of Certification

5.1 National Standards Authority of Ireland ("NSAI") following consultation with NSAI Agrment has assessed the performance and method of installation of the product/process and the quality of the materials used in its manufacture and certifies the product/process to be fit for the use for which it is certified provided that it is manufactured, installed, used and maintained in accordance with the descriptions and specifications set out in this Certificate and in accordance with the manufacturer's instructions and usual trade practice. This Certificate shall remain valid for five years from date of issue so long as: (a) the specification of the product is unchanged. (b) the Building Regulations 1997 to 2008 and any other regulation or standard applicable to the product/process, its use or installation remains unchanged. (c) the product continues to be assessed for the quality of its manufacture and marking by NSAI. (d) no new information becomes available which in the opinion of the NSAI, would preclude the granting of the Certificate. (e) the product or process continues to be manufactured, installed, used and maintained in accordance with the description, specifications and safety recommendations set out in this certificate. (f) the registration and/or surveillance fees due to NSAI Agrment are paid. 5.2 The NSAI Agrment mark and certification number may only be used on or in relation to product/processes in respect of which a valid Certificate exists. If the Certificate becomes invalid the Certificate holder must not use the NSAI Agrment mark and certification number and must remove them from the products already marked.

5.3 In granting Certification, the NSAI makes no representation as to; (a) the absence or presence of patent rights subsisting in the product/process; or (b) the legal right of the Certificate holder to market, install or maintain the product/process; or (c) whether individual products have been manufactured or installed by the Certificate holder in accordance with the descriptions and specifications set out in this Certificate. 5.4 This Certificate does not comprise installation instructions and does not replace the manufacturer's directions or any professional or trade advice relating to use and installation which may be appropriate. 5.5 Any recommendations contained in this Certificate relating to the safe use of the certified product/process are preconditions to the validity of the Certificate. However the NSAI does not certify that the manufacture or installation of the certified product or process in accordance with the descriptions and specifications set out in this Certificate will satisfy the requirements of the Safety, Health and Welfare at Work Act 2005, or of any other current or future common law duty of care owed by the manufacturer or by the Certificate holder. 5.6 The NSAI is not responsible to any person or body for loss or damage including personal injury arising as a direct or indirect result of the use of this product or process. 5.7 Where reference is made in this Certificate to any Act of the Oireachtas, Regulation made thereunder, Statutory Instrument, Code of Practice, National Standards, manufacturer's instructions, or similar publication, it shall be construed as reference to such publication in the form in which it is in force at the date of this Certification.

Certificate No. 09/0340 /Ceresit-Ceretherm External Wall Insulation Systems

NSAI Agrment
This Certificate No. 09/0340 is accordingly granted by the NSAI to Insulated Render Systems Ltd. on behalf of NSAI Agrment. Date of Issue: November 2009 Signed

Sen Balfe Director of NSAI Agrment Readers may check that the status of this Certificate has not changed by contacting NSAI Agrment, NSAI, 1 Swift Square, Northwood, Santry, Dublin 9, Ireland. Telephone: (01) 807 3800. Fax: (01) 807 3842. www.nsai.ie

Certificate No. 09/0340 /Ceresit-Ceretherm External Wall Insulation Systems

CERTIFICATE NO. 09/0340 DETAIL SHEET 1

Ceresit VWS Classic

PRODUCT DESCRIPTION This Detail Sheet relates to Ceresit VWS Classic, as defined in NSAI Agrment Certificate 09/0340. USE: The system is for use as external insulation for refurbishment/retrofit of existing masonry or concrete buildings, up to a maximum of six storeys (18 metres) in height in purpose groups 1(a), 1(b), 1(c), 2(a), 2(b), 3, 4(a) and 4 as defined in TGD to Part B of the Building Regulations 1997 to 2008.

Part One /

Certification

1.1 ASSESSMENT In the opinion of NSAI Agrment, Ceresit VWS Classic, if used in accordance with this Detail Sheet, meets the requirements of the Building Regulations 1997 - 2008 as indicated in Section 1.2 of Certificate 09/0340. 1.2 BUILDING REGULATIONS 1997 to 2008 This matter is dealt with in NSAI Agrment Certificate 09/0340.

Certificate No. 09/0340 Detail Sheet 1/Ceresit VWS Classic

Part Two /

Technical Specification and Control Data

2.1 PRODUCT DESCRIPTION The Ceresit VWS Classic system is summarised in Table 1. The minimum overall thickness of base coat and decorative finish coat is 6 to 8mm.
Components Insulation product: EPS-EN 13163-T1-L1-W1-S1-P3-DS(70,-)2-BS150-CS(10)100-DS(N)5-DLT(1)5 Insulation materials with associated methods of fixing Supplementary adhesive: CT 83 CT 85 Anchors: CT 335 Base coat Glass fibre mesh Key coat / Primer CT 85 CT 325 CT 15 CT 16 Dry mortars mineral binder: CT 35 (particle size 2.5, 3.5 mm) CT 36 (particle size 2.0 mm) CT 137 (particle size 1.5, 2.0, 2.5 mm) Ready to use pastes acrylic binder: CT 60 (particle size 1.5, 2.5 mm) CT 63 (particle size 3.0 mm) CT 64 (particle size 2.0 mm) Finishing coats Ready to use pastes silicate binder: CT 72 (particle size 1.5, 2.5 mm) CT 73 (particle size 2.0, 3.0 mm) Ready to use pastes silicone binder: CT 74 (particle size 1.5, 2.5 mm) CT 75 (particle size 2.0, 3.0 mm) Ready to use pastes mosaic plaster: CT 77 (particle size 1.4, 2.0 mm) Thickness (mm) 50 to 200 4.0 -

Regulated by particle size

Table 1: Definition of the Construction Product (Kit)

Certificate No. 09/0340 Detail Sheet 1/Ceresit VWS Classic

CERTIFICATE NO. 09/0340 DETAIL SHEET 2

Ceresit-Ceretherm VWS Popular

PRODUCT DESCRIPTION This Detail Sheet relates to Ceresit-Ceretherm VWS Popular, as defined in NSAI Agrment Certificate 09/0340. USE: The system is for use as external insulation for refurbishment/retrofit of existing masonry or concrete buildings, up to a maximum of six storeys (18 metres) in height in purpose groups 1(a), 1(b), 1(c), 2(a), 2(b), 3, 4(a) and 4 as defined in TGD to Part B of the Building Regulations 1997 to 2008.

Part One /

Certification

1.1 ASSESSMENT In the opinion of NSAI Agrment, CeresitCeretherm VWS Popular, if used in accordance with this Detail Sheet, meets the requirements of the Building Regulations 1997 - 2008 as indicated in Section 1.2 of Certificate 09/0340. 1.2 BUILDING REGULATIONS 1997 to 2008 This matter is dealt with in NSAI Agrment Certificate 09/0340.

Certificate No. 09/0340 Detail Sheet 2/Ceresit-Ceretherm VWS Popular

Part Two /

Technical Specification and Control Data

2.1 PRODUCT DESCRIPTION The Ceresit-Ceretherm VWS Popular system is summarised in Table 1. The minimum overall thickness of base coat and decorative finish coat is 6 to 8mm.
Components CERESIT ZS CERESIT ZU CT 85 EPS-EN EPS-EN EPS-EN EPS-EN EPS-EN EPS-EN EPS-EN EPS-EN CT 335 CT 85 CT 87 CT 325 Mesh size: 3.5 x 4.0 mm, to 5.0 x 5.0 mm Mass per unit area: 145 g/m2 to 165 g/m2 CT 15 CT 16 Dry mortars mineral binder: CT 35 (particle size 2.5, 3.5 mm) CT 36 (particle size 2.0 mm) CT 137 (particle size 1.5, 2.5 mm) Ready to use pastes acrylic binder: CT 60 (particle size 1.5, 2.5 mm) CT 63 (particle size 3.0 mm) CT 64 (particle size 2.0 mm) Finishing coats Ready to use pastes silicate binder: CT 72 (particle size 1.5, 2.5 mm) CT 73 (particle size 2.0, 3.0 mm) Ready to use pastes silicone binder: CT 74 (particle size 1.5, 2.5 mm) CT 75 (particle size 2.0, 3.0 mm) Ready to use pastes mosaic plaster: CT 77 (particle size 1.4, 2.0 mm) Decorative coats (Paints) CT CT CT CT 42 44 48 54 13163-T2-L2-W2-S1-P3-BS115-CS(10)70-DS(N)2-DS(70,-)2-TR100 13163-T2-L2-W2-S2-P4-BS115-CS(10)70-DS(N)2-DS(70,-)2-TR100 13163-T2-L2-W2-S2-P3-BS115-CS(10)70-DS(N)2-DS(70,-)2-TR100 13163-T2-L2-W2-S2-P4-BS115-CS(10)70-DS(N)2-DS(70,0)1-TR150 13163-T2-L2-W2-S1-P3-BS75-DS(N)2-DS(70,-)2-TR80 13163-T2-L2-W2-S1-P3-BS100-DS(N)2-DS(70,-)2-TR100 13163-T2-L2-W2-S1-P3-BS115-DS(N)2-DS(70,-)2-TR100 13163-T2-L2-W2-S2-P3-BS115-DS(N)2-DS(70,-)2-TR100 Thickness (mm) -

Adhesives

Insulation

20 to 250

Anchors Base coat Glass fibre meshes Key coat / Primer

4.0

Regulated by particle size

Table 1: Definition of the Construction Product (Kit)

Certificate No. 09/0340 Detail Sheet 2/Ceresit-Ceretherm VWS Popular

CERTIFICATE NO. 09/0340 DETAIL SHEET 3

Ceresit-Ceretherm VWS & WM Premium

PRODUCT DESCRIPTION This Detail Sheet relates to Ceresit-Ceretherm VWS & WM Premium, as defined in NSAI Agrment Certificate 09/0340.

USE: The system is for use as external insulation for refurbishment/retrofit of existing masonry or concrete buildings, up to a maximum of six storeys (18 metres) in height in purpose groups 1(a), 1(b), 1(c), 2(a), 2(b), 3, 4(a) and 4 as defined in TGD to Part B of the Building Regulations 1997 to 2008.

Part One /

Certification

1.1 ASSESSMENT In the opinion of NSAI Agrment, CeresitCeretherm VWS & WM Premium, if used in accordance with this Detail Sheet, meets the requirements of the Building Regulations 1997 2008 as indicated in Section 1.2 of Certificate 09/0340.

1.2 BUILDING REGULATIONS 1997 to 2008 This matter is dealt with in NSAI Agrment Certificate 09/0340.

Certificate No. 09/0340 Detail Sheet 3/Ceresit-Ceretherm VWS & WM Premium

Part Two /

Technical Specification and Control Data

2.1 PRODUCT DESCRIPTION The Ceresit-Ceretherm VWS & WM Premium system is summarised in Table 1. The minimum overall thickness of base coat and decorative finish coat is 6 to 8mm.
Components Adhesives CT 87 EPS-EN EPS-EN EPS-EN EPS-EN EPS-EN EPS-EN EPS-EN EPS-EN 13163-T2-L2-W2-S1-P3-BS115-CS(10)70-DS(N)2-DS(70,-)2-TR100 13163-T2-L2-W2-S2-P4-BS115-CS(10)70-DS(N)2-DS(70,-)2-TR100 13163-T2-L2-W2-S2-P3-BS115-CS(10)70-DS(N)2-DS(70,-)2-TR100 13163-T2-L2-W2-S2-P4-BS115-CS(10)70-DS(N)2-DS(70,0)1-TR150 13163-T2-L2-W2-S1-P3-BS75-DS(N)2-DS(70,-)2-TR80 13163-T2-L2-W2-S1-P3-BS100-DS(N)2-DS(70,-)2-TR100 13163-T2-L2-W2-S1-P3-BS115-DS(N)2-DS(70,-)2-TR100 13163-T2-L2-W2-S2-P3-BS115-DS(N)2-DS(70,-)2-TR100 Thickness (mm) -

Insulation

20 to 250

MW-EN 13162-T5-CS(10)40-TR15-WS-DS(TH)-MU1 Mineral Wool (disturbed fibre) Board and Lamella (lamella wool) Strip Anchors Base coat Glass fibre meshes Key coat / Primer CT 335 CT 87 CT 325 Mesh size: 3.5 x 4.0 mm, to 5.0 x 5.0 mm Mass per unit area: 145 g/m2 to 165 g/m2 CT 16 Dry mortars mineral binder: CT 35 (particle size 2.5, 3.5 mm) CT 36 (particle size 2.0 mm) CT 137 (particle size 1.5, 2.5 mm) Ready to use pastes acrylic binder: CT 60 (particle size 1.5, 2.5 mm) CT 63 (particle size 3.0 mm) CT 64 (particle size 2.0 mm) Finishing coats Ready to use pastes silicate binder: CT 72 (particle size 1.5, 2.5 mm) CT 73 (particle size 2.0, 3.0 mm) Ready to use pastes silicone binder: CT 74 (particle size 1.5, 2.5 mm) CT 75 (particle size 2.0, 3.0 mm) Ready to use pastes mosaic plaster: CT 77 (particle size 1.4, 2.0 mm) Decorative coats (Paints) CT CT CT CT 42 44 48 54 4.0

Regulated by particle size

Table 1: Definition of the Construction Product (Kit)

Certificate No. 09/0340 Detail Sheet 3/Ceresit-Ceretherm VWS & WM Premium

CERTIFICATE NO. 09/0340 DETAIL SHEET 4

Ceresit-Ceretherm VWS Express

PRODUCT DESCRIPTION This Detail Sheet relates to Ceresit-Ceretherm VWS Express, as defined in NSAI Agrment Certificate 09/0340.

USE: The system is for use as external insulation for refurbishment/retrofit of existing masonry or concrete buildings, up to a maximum of six storeys (18 metres) in height in purpose groups 1(a), 1(b), 1(c), 2(a), 2(b), 3, 4(a) and 4 as defined in TGD to Part B of the Building Regulations 1997 to 2008.

Part One /

Certification

1.1 ASSESSMENT In the opinion of NSAI Agrment, CeresitCeretherm VWS Express, if used in accordance with this Detail Sheet, meets the requirements of the Building Regulations 1997 - 2008 as indicated in Section 1.2 of Certificate 09/0340.

1.2 BUILDING REGULATIONS 1997 to 2008 This matter is dealt with in NSAI Agrment Certificate 09/0340.

Certificate No. 09/0340 Detail Sheet 4/Ceresit-Ceretherm VWS Express

Part Two /

Technical Specification and Control Data

2.1 PRODUCT DESCRIPTION The Ceresit-Ceretherm VWS Express system is summarised in Table 1. The minimum overall thickness of base coat and decorative finish coat is 6 to 8mm.
Components Adhesives CT 84 Express EPS-EN 13163-T2-L2-W2-S2-P3-BS115-CS(10)70-DS(N)2-DS(70,-)2-TR100 EPS-EN 13163-T2-L2-W2-S2-P4-BS125-CS(10)80-DS(N)2-DS(70,-)2-TR100 EPS-EN 13163-T2-L2-W2-S1-P3-BS75-DS(N)2-DS(70,-)3-TR80 CT 335 CT 85 CT 87 CT 325 Mesh size: 3.5 x 4.0 mm, to 5.0 x 5.0 mm Mass per unit area: 145 g/m2 to 165 g/m2 CT 15 CT 16 Dry mortars mineral binder: CT 35 (particle size 2.5, 3.5 mm) CT 36 (particle size 2.0 mm) CT 137 (particle size 1.5, 2.5 mm) Ready to use pastes acrylic binder: CT 60 (particle size 1.5, 2.5 mm) CT 63 (particle size 3.0 mm) CT 64 (particle size 2.0 mm) Finishing coats Ready to use pastes silicate binder: CT 72 (particle size 1.5, 2.5 mm) CT 73 (particle size 2.0, 3.0 mm) Ready to use pastes silicone binder: CT 74 (particle size 1.5, 2.5 mm) CT 75 (particle size 2.0, 3.0 mm) Ready to use pastes mosaic plaster: CT 77 (particle size 1.4, 2.0 mm) Decorative coats (Paints) CT CT CT CT 42 44 48 54 Thickness (mm) -

Insulation

20 to 250

Anchors Base coat Glass fibre meshes Key coat / Primer

4.0

Regulated by particle size

Table 1: Definition of the Construction Product (Kit)

Certificate No. 09/0340 Detail Sheet 4/Ceresit-Ceretherm VWS Express