DM4 Dual Digital Micro-Manometer


measures two pressures from -3.0 "wc (750 Pa) to +2.2 "wc (548 Pa) with a resolution of 0.001 "wc or 0.1 Pa and an accuracy of 1% of the measurement.

| New | Search | Links | Infiltec | Staff | Fun | RADON CONTROL | About Radon | Radon FAQ | Pictures | Drawings | Fans | Large Buildings | Radon Catalog | AIR LEAKAGE | About Blower Doors | FAQ | Ducts | Fire | Large Buildings | Contractors | Blower Door Catalog |

The DM4 is a portable dual digital micro-manometer with the easy-to-use 0.001 "wc or 0.1 Pa resolution. It is calibrated for blower doors, duct leakage testers and Pitot tube measurements. (click on thumbnail below for larger image)
z z z z z z

Calibrated for Infiltec E3 blower door flow and leakage area, calibrated for Minneapolis Model 3 blower door flow and leakage area, calibrated for Pitot tube air velocity, calibrated for Infiltec DL1 duct leakage flow and leakage area, and calibrated for Infiltec mobile fans for testing the leakage of large buildings. Other Uses: { HVAC test and balance, { Data logging pressure and flow, { Radon mitigation, { Furnace draft analysis, { Duct leakage testing, { Pressure balancing, { Combustion safety analysis, { Advanced building diagnostics, { Laboratory safety monitoring, { Process monitoring, { Filter condition checks, { Environmental assessments, and { Orifice pressure measurements.

DM4 Dual Digital Micro-Manometer Specifications


Feature Sensors: Pressure Resolution: Pressure Range: Specifications 2 independent differential pressure transducers with auto zeroing Display resolution is 0.1 Pa from -750.0 Pa to +548.0 Pa or 0.001 "wc from -3.000 "wc to +2.200 "wc. Internal resolution is 1/40 Pa or 0.0001 "wc and this is the resolution of the serial output. Bi-directional: -3.0 "wc (750 Pa) to +2.2 "wc (548 Pa). For higher pressures, see the Infiltec DM5.

http://www.infiltec.com/inf-dm4s.htm

8/25/2011

INFILTEC: DM4 Dual Digital Micro-Manometer Specifications - micromanometer, low ... Page 2 of 4

Keys: - Device Key:

- Units Key:

- Time Avg Key:

- Low Flow Key:

- Baseline Key: - Hold Key: - On/Off Key:

Accuracy:

Display Type: Operating

7 function selection keys. Select: Manometer, Pitot tube, E3 blower door, DL1 duct tester devices. Dual Manometer: Metric (Pa, Pa), U.S. ("wc, "wc), Mixed ("wc, Pa) Pitot flow: Metric (Pa, m/s), U.S. ("wc, f/m), Mixed (Pa, fpm) Infiltec E3 blower door flow: Metric (Pa, m3/h), U.S. ("wc, cfm), Mixed (Pa, cfm) Infiltec E3 blower door ELA (leakage area): Metric (Pa, cm2), U.S. ("wc, in2), Mixed (Pa, in2) Minneapolis Model 3 blower door flow: Metric (Pa, m3/h), U.S. ("wc, cfm), Mixed (Pa, cfm) Minneapolis Model 3 blower door ELA (leakage area): Metric (Pa, cm2), U.S. ("wc, in2), Mixed (Pa, in2) Infiltec DL1 duct tester flow: Metric (Pa, m3/h), U.S. ("wc, cfm), Mixed (Pa, cfm) Infiltec DL1 duct tester ELA (leakage area): Metric (Pa, cm2), U.S. ("wc, in2), Mixed (Pa, in2). Select block average of 1 (default), 2, 4, 8, 16, 32 or 64 seconds. Dual Manometer: no function Pitot tube flow: no function Infiltec E3 blower door low flow plate: Off, CRF (Can't reach 50 Pa), 7 holes open, 5 open, 3 open, 2 open, 1 open Minneapolis Model 3 blower door low flow rings: Off, CRF (Can't reach 50 Pa), A Ring, B Ring, C Ring Infiltec DL1 duct tester orifice tubes: Off, 16 cm2 tube on, 4 cm2 tube on, 1 cm2 tube on Resets the zero building pressure for Infiltec E3 or Minneapolis Model 3 blower door calculations. Holds reading on display until pressed again. Turn power on and off. Dual Pressure: 1% of display measurement or 1 digit, whichever is greater. Pitot Flow: 1.5% of measurement or better from 800-6900 fpm (4-35 m/s) Infiltec E3 blower door flow or ELA: 1.5% of measurement or better Minneapolis Model 3 blower door flow or ELA: 1.5% of measurement or better Infiltec DL1 duct leakage flow or ELA: 1.5% of measurement or better 2x16 high contrast LCD with numbers and characters. 32F to 122F. (0C to 50C)

http://www.infiltec.com/inf-dm4s.htm

8/25/2011

INFILTEC: DM4 Dual Digital Micro-Manometer Specifications - micromanometer, low ... Page 3 of 4

Temperature: Storage Temperature: Maximum Pressure: Low Battery Display: Over Range Indicator: Auto Zero: Weight With Battery: Dimensions: Battery Life: Operating Medium: Pressure Connections:

-4F to 160F. (-20C to 70C) 25 "wc, 6 kPa or 0.9 PSI Current battery voltage is displayed at startup, "lowbat" displayed when voltage is under 7 volts. !!MAX!! displayed when pressure is beyond range -3.0 "wc (750 Pa) to +2.2 "wc (548 Pa). Pneumatic switches update zero pressure estimates every 8 seconds. ~16 oz. (~455 grams) 4.0"x7.5"x1.79" (101.6x190.5x45.4 mm). Over 100 hours from six AA alkaline batteries. Air or non-corrosive, non-explosive gas. Two pairs, barbed for 1/8" ID tubing.

9600-8N0 pseudo RS232 ASCII records at 1 Hz with LF+CR termination Serial Output: 32767 range, 1/40 Pa resolution, comma separates two channel values Programmable 4 Mhz Microchip PIC14000 with 16 bit a/d. Microprocessor: DM4 functions can be updated by replacing this chip. Custom microprocessor programming is available to optimize Custom Firmware: the DM4 for your pressure/flow/ELA measurement application. Optional E3 blower door, DL1 duct tester, Pitot tube, serial cable, 110 Accessories: VAC or 220 VAC power adaptor. Accessories Battery, soft carrying case, tubing, calibration certificate, user Included: manual. Warranty: 2 years coverage on parts and labor to repair any defects.
These specifications were updated on February 22, 2005, and are subject to change without notice.

For current DM4 prices, see the Infiltec Radon or Blower Door catalogs, or call toll free (888) 349-7236.