hi guys, in the network i supervised, there are some cells experienced power congestion.

in huawei system, how is the best solution to solved this problem. many thanks f or your response. =================== Hi, If the cell in a real ower congestion ,power upgrade is necessary but there are some ideas to reduce the power congestion: 1- Check the SHO ratio, try to minimize the SHO overheads 2- Push PS users to be mapped over HSDPA 3- Check the coverage, CPICH foot print, reducing the CPICH or downtilting the a ntenna may reduce the coverage and save some power from boarder users 4- Ensure that VSWR is normal 5- Try to use Micro NodeBs with Fiber connectivity to decrease the feeder losses good luck. please add rep if this is useful =========================== you can also enable LDR feature for the power congestion, there are many actions like InterRAT handover and Rate reduction. =============================== Hi all, All the said above is good approach. Just to share some of my thoughts check if this is UL or DL power congestion. In case it is UL Call admission control can be modified by increasing "Uplink to tal equivalent user number" if it is set to low levels (e.g the default one -fee l free to try higher values 100, 100+). If it is DL check the HW type - maybe MA XTXPWR is not set to the maximum allowed by the HW (e.g MTRU supports 46 dBm but Max TXPOWER is set to 43 dBM). ================================== I thin this can be the last solution. it is better to follow the steps described by Sala70.. start by checking SHO rate =================================== HI all, If there are UL power congestion,maybe the SSCCH power is lower to the baseline value. ================================= Hi, for the HSPA, beside the R99 service power,Nodeb will assaign all power to HSPA service when HSPA need more power.And the power of R99 is a constant value,but t he power of HSPA is not fix. =================================

RTWP 2012-12-04, 07:25 PM In nodeB bts level change or MOD RXBRANCH attenuation from 0 to 45 RTWP initial0 (0.1dB) from 0 to -55 Before change this parameter make sure first cabinet - subrack and slot number. giegala 2012-12-14, 08:08 PM Hi, the problem have been identified. Our setup is to have 3x of RRC release complet e to be sent by UE. However RNC was setup to release RL even after reception of first RRC RELEASE CMP message. Therefore UE will have RL lost and would be rampi ng UL power causing uncontrolled UL interference. After RNC was setup to delay RL, RTWP issue was solved.

Você também pode gostar