Sepam series 10
series 20
Page 52
Protections
Current Voltage Frequency Specifics
phase and earth fault overcurrent phase and earth fault overcurrent earth fault overcurrent breaker failure
b b b b b
disconnection by rate of change of frequency
Applications
Substation P. 18
S20
S2
B22
M20
Characteristics
Logic inputs/ outputs
I + Io
0 I + Io
0 Io
0 to 10 to 8 0 to 8 I + Io
0 to 10 to 8 0 to 8 V + Vo
Yes
Yes
Control
Logic equation editor Logipam () Backup Front Memory cartridge with settings
Other
(1) LPCT: low-power current transducer complying with standard IEC 00-8. (2) Control matrix for simple assignment of information from the protection, control and monitoring functions. () Logipam ladder language (PC programming environment) to make full use of Sepam series 80 functions. () Standard lithium battery 1/2 AA format . V front face exchangeable.
1
series 0
Page 53
series 0
Page 90
Protections
Current Voltage Frequency Specifics b b b b b b
directional earth fault
b b b
b b b
b b b
b b b
directional earth fault
b b b
directional earth fault and phase overcurrent
Applications
Substation P. 18
S0 S0
()
S1 S1
()
S2 S2
()
S S
()
S S
S0
S2
T0 T0
()
T0
T2
M0 G0
Characteristics
Logic inputs/ outputs
0 to 28 to 1 0 to 1 I + Io V, 2U + Vo or Vnt Yes 1 to 2 Yes Yes Yes Yes Yes Lithium battery() Yes
Control
Logic equation editor Logipam () Backup Front Memory cartridge with settings
Other
(1) LPCT: low-power current transducer complying with standard IEC 00-8. (2) Control matrix for simple assignment of information from the protection, control and monitoring functions. () Logipam ladder language (PC programming environment) to make full use of Sepam series 80 functions. () Standard lithium battery 1/2 AA format . V front face exchangeable.
1
series 80
Page 137
b b b
b b b
directional earth fault
b b b
directional earth fault and phase overcurrent
b b b
disconnection by rate of change of frequency
b b b
transformer & transformermachine unit differential
b b b
machine differential
b b b
voltage and frenquency protection for 2 sets of busbars
b b b
capacitor-bank unbalance
S80
S81
S82
S8
B8
M81 G82
M88 G88
0 to 2 to 2 0 to 1 I + 2 x Io V + Vo Yes 2 to Yes Yes Yes Yes Yes Yes Lithium battery() Yes
0 to 2 to 2 0 to 1 2 x I + 2 x Io V + Vo Yes 2 to Yes Yes Yes Yes Yes Yes Lithium battery() Yes
0 to 2 to 2 0 to 1 I + Io 2 x V + 2 x Vo Yes 2 to Yes Yes Yes Yes Yes Yes Lithium battery() Yes
0 to 2 to 2 0 to 1 2 x I + 2 x Io V + Vo Yes 2 to Yes Yes Yes Yes Yes Yes Lithium battery() Yes
() SX applications are identical to SX applications with the following additional functions: b earth fault and phase overcurrent cold load pick-up, b broken wire detection, b fault locator. () TX applications are identical to TX applications with the following additional functions: b earth fault and phase overcurrent cold load pick-up b broken wire detection.
1