Você está na página 1de 109

8HVZ Ancore chimice

pentru sarcini mari n zon ntins


Timp de ntrire
Temperatur n gaur + 20 C + 10 C 0 C - 5 C
Interval de ateptare ntre poziionare i ncrcare 20 min. 30 min. 1 or 5 ore
HVU-TZ Cartue pentru ancore chimice
Adncime gaur=
lungime cartu (mm)
xnominal
burghiu (mm)
Adncime
de pozare (mm)
Cod
comand
Nr. articol
90 12 90 HVU-TZ M10x90 311368 10
110 14 110 HVU-TZ M12x110 311369 10
125 / 145 18 105 / 125 HVU-TZ M16x125 311370 5
195 25 170 HVU-TZ M20x170 335942 4
HAS-TZ Tij de ancorare
15 124 75 12 HAS-TZ M10x75/15 310018 10
30 139 75 12 HAS-TZ M10x75/30 308383 10
50 159 75 12 HAS-TZ M10x75/50 308384 10
25 158 95 14 HAS-TZ M12x95/25 308385 10
50 183 95 14 HAS-TZ M12x95/50 308386 10
100 233 95 14 HAS-TZ M12x95/100 308387 10
30 181 105 18 HAS-TZ M16x105/30 308388 5
60 211 105 18 HAS-TZ M16x105/60 308389 5
100 251 105 18 HAS-TZ M16x105/100 308390 5
30 201 125 18 HAS-TZ M16x125/30 332519 5
60 231 125 18 HAS-TZ M16x125/60 332520 5
100 271 125 18 HAS-TZ M16x125/100 332521 5
40 269 170 25 HAS-TZ M20x170/40 335943 4
Date tehnice
Extras din aprobarea ETA: ETA-03/0032
HVZ/HAS-TZ M10 M12 M16x105 M16x125 M20
Material de ancorare Beton C20/25
1)
Solicitare la traciune adm. (zon comprimat) N [kN] 15,6 19,1 25,8 33,6 53,2
1)
Solicitare la traciune admis (zon ntins) N [kN] 9,5 15,9 18,4 23,9
1)
Solicitare la forfecare admis V [kN] 10,3 15,4 29,1 29,1 50,3
Distan necesar fa de margine Ccr [cm] 11,5 14,5 15,5 18,5 25,5
Distan necesar ntre axe Scr [cm] 22 30 33 39 51
2)
Distan minim fa de margini Cmin [cm] 5 7 8,5 8,5 8
2)
Distan minim ntre axe Smin [cm] 5 6 7 7 8
Diametru gaur do [mm] 12 14 18 18
Adncime gaur h1 [cm] 9 11 12,5 14,5
Grosime min. element de construcie hmin [cm] 15 19 21 25
Gaur de trecere [mm] 13 15 19 19 22
Moment de strngere Tinst [Nm] 40 50 90 90
HVU-TZ Cartu pentru ancora chimic
HAS-TZ / HAS-R TZ Tij de ancorare
Deschidere cheie SW [mm] 19 24 24 30 17
38
25
19,5
34
150
1)
Sarcinile admisibile sunt valabile pentru fixri individuale la distan fa de margini, cu armtur dens, coeficient
parial de siguran al aplicrii forei 1,4
2)
Sarcinile admisibile trebuiesc reduse n conformitate cu aprobarea ETA
Informaii suplimentare putei gsi n Manualul tehnicii de ancorare Hilti, sau pe Internet la adresa www.hilti.ro.
h(min) tfix
Tinst.
h1
Buc./
ambalaj
Execuie: cu piuli i aib de susinere. Material oel 8.8, zincat galvanic cu 5 m
nlime
de fixare
Lungime
tij (mm)
Adncime de
pozare (mm)
Cod
comand
Nr. articol Buc./
ambalaj
xnominal
burghiu (mm)
130
Ancore pentru sarcini mari / Chimice
HAS-R-TZ Tije de ancorare inoxidabile A4
Execuie: cu piuli i aib de susinere.
Material: oel inoxidabil A4-80, indice material 1.4401 / 1.4571
15 124 75 12 HAS-R-TZ M10x75/10 310019 10
30 139 75 12 HAS-R-TZ M10x75/30 308391 10
50 159 75 12 HAS-R-TZ M10x75/50 308392 10
25 158 95 14 HAS-R-TZ M12x95/25 308393 10
50 183 95 14 HAS-R-TZ M12x95/50 308394 10
100 233 95 14 HAS-R-TZ M12x95/100 308395 10
30 181 105 18 HAS-R-TZ M16x105/30 308396 5
60 211 105 18 HAS-R-TZ M16x105/60 308397 5
100 251 105 18 HAS-R-TZ M16x105/100 308398 5
30 201 125 18 HAS-R-TZ M16x125/30 332522 5
60 231 125 18 HAS-R-TZ M16x125/60 332523 5
100 271 125 18 HAS-R-TZ M16x125/100 332524 5
40 269 170 25 HAS-R-TZ M20x170/40 335944 4
HAS-HCR-TZ Tije de ancorare
cu mare rezisten la coroziune
Execuie: cu piuli i aib de susinere.
Material: oel inoxidabil A4-80, indice material 1.4529
15 124 75 12 HAS-HCR-TZ M10x75/10* 336269 10
30 139 75 12 HAS-HCR-TZ M10x75/30* 336270 10
50 159 75 12 HAS-HCR-TZ M10x75/50* 336271 10
25 158 95 14 HAS-HCR-TZ M12x95/25* 336272 10
50 183 95 14 HAS-HCR-TZ M12x95/50* 336273 10
100 233 95 14 HAS-HCR-TZ M12x95/100* 336274 10
30 181 105 18 HAS-HCR-TZ M16x105/30* 336275 5
60 211 105 18 HAS-HCR-TZ M16x105/60* 336276 5
100 251 105 18 HAS-HCR-TZ M16x105/100* 336277 5
30 201 125 18 HAS-HCR-TZ M16x125/30* 336278 5
60 231 125 18 HAS-HCR-TZ M16x125/60* 336279 5
100 271 125 18 HAS-HCR-TZ M16x125/100* 336280 5
40 269 170 25 HAS-HCR-TZ M20x170/40* 335945 4
* timpul de livrare se comunic la cerere
Dispozitiv de montaj pentru tije de ancorare HAS-TZ / R-TZ / HCR-TZ
cu cap hexagonal
Pentru
dimensiune HAS
Cap de
fixare
Cod
comand
Nr. articol Buc./
ambalaj
M10 TE-C TE-C HEX M10 311415 1
M12 TE-C TE-C HEX M12 311416 1
M16 TE-C TE-C HEX M16 311417 1
M20 TE-Y TE-Y HEX M20 336420 1
HAS-TZ Tije de ancorare lungimi speciale
nlime
de fixare
Lungime
tij (mm)
Adncime de
pozare (mm)
Cod
comand
Nr. articol Buc./
ambalaj
x nominal
burghiu (mm)
nlime
de fixare
Lungime
tij (mm)
Adncime de
pozare (mm)
Cod
comand
Nr. articol Buc./
ambalaj
x nominal
burghiu (mm)
Confecionm n scurt timp orice lungime special dorit de Dumneavoastr. Preurile i timpul de livrare se comunic la cerere!
131
T
e
h
n
i
c
a

a
n
c
o
r

r
i
i
Ancore pentru sarcini mari / Chimice
9HVA Ancor chimic
pentru sarcini mari n zona comprimat
Timp de ntrire
Temperatur n gaur + 20 C + 10 C 0 C - 5 C
Interval de ateptare ntre poziionare i ncrcare 20 min. 30 min. 1 or 5 ore
Date tehnice
Valorile sarcinilor conform Manualului tehnicii de fixare Hilti i Eurocode (procedura CC):
HVA/HVU cu HAS tij de ancorare M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Suprafa de ancorare Beton fr fisuri C20/25
1)
Solicitare la traciune admis N [kN] 7,8 11,8 17,0 24,8 44,9 64,7 79,2 104,0 122,1 145,2 166,4
1)
Solicitare la forfecare admis V [kN] 5,6 9,0 13,1 24,7 38,6 55,6 117,1 142,4 177,4 208,2 250,4
Distan necesar fa de margine Ccr [cm] 8,0 9,0 11,0 12,5 17,0 21,0 24,0 27,0 30,0 33,0 36,0
Distan necesar ntre axe Scr [cm] 16,0 18,0 22,0 25,0 34,0 42,0 48,0 54,0 60,0 66,0 72,0
2)
Distan minim fa de margini Cmin [cm] 4,0 4,5 5,5 6,3 8,5 10,5 12,0 13,5 15,0 16,5 18,0
2)
Distan minim ntre axe Smin [cm] 4,0 4,5 5,5 6,3 8,5 10,5 12,0 13,5 15,0 16,5 18,0
Diametru gaur d0 [mm] 10 12 14 18 24 28 30 35 37 40
Adncime gaur h1 [cm] 8 9 11 12,5 17 21 24 27 30 33
Gaur de trecere [mm]
10 12 14 17 22 27 30 34 38 41
h
o

h
d
o
1)
Sarcinile admisibile sunt valabile pentru fixri individuale la distan fa de margini, cu armtur dens,
coeficient parial de siguran al aplicrii forei 1,4
2)
Sarcinile admisibile trebuiesc reduse n conformitate cu procedura CC,
conform Manualului tehnicii de ancorare Hilti.
Informaii suplimentare putei gsi n Manualul tehnicii de ancorare Hilti, sau pe Internet la adresa www.hilti.ro.
HVU Cartue pentru ancore chimice
Avantaje:
nMontaj simplu i rapid.
nCartu flexibil se potrivete i n guri curbe.
nCartu rezistent la rupere nu exist pericolul rnirii.
nDepozitare uoar nu este posibil spargerea.
nCartu n form de sgeat cartuul rmne atrnat n gaur (fixri n tavan).
nValori mari de sarcin, valorificarea rezistenei barelor de oel, deplasare optim a sarcinilor,
rezisten n timp, comportament optim n caz de incendiu.
nNu prezint tendin de contracie, ceea ce ofer o mare siguran timp ndelungat.
nNou sistem hibrid: fr stiren i aditivi de nmuiere, ceea ce l face fr miros.
HVU Cartu pentru ancor chimic
HAS / HAS-R Tij de ancorare
HAS-E / HAS-ER Tij de ancorare
Moment de strngere Tinst [Nm]
11 13 15 19 25 29 31 36 38 41
Deschidere cheie SW [mm]
Grosime minim element de construcie hmin [cm]
42
36
45
43
18 35 60 120 260 450 650 950 1200 1500 43
13 17 19 24 30 36 41 46 50 55 59
132
Ancore pentru sarcini mari / Chimice
q0 Tij de ancorare HIT-TZ / HIT-RTZ i mortar de injecie HIT-HY 150
Sistemul de injecie pentru beton cu fisuri
Avantaje:
n
n
n
n
Sigur: independent de starea gurii murdar,
umed, perforat cu diamant
Siguran: sprijin ulterior sigur n fisur, potrivit
pentru zona ntins (tavan)
Utilizare uoar: funcioneaz cu mortarul de
injecie clasic HIT-HY 150
Economic: adncime de ncastrare redus (circa
30% mai mic dect la tijele de ancorare HAS)
Procedur de pozare:
Conform aprobrii DlBt, pentru HIT-TZ M16 i HIT-TZ M20 gaura trebuie curat (2 x pompare / 2 curare cu peria / 2 x pompare)
137
Date tehnice
Extras din aprobarea ETA: ETA-03/0084
HIT-HY 150 i HIT-TZ Tije de ancorare M8 M10 M12 M16 M20
Material de ancorare Beton C20/25
1)
Solicitare la traciune admis (zon comprimat) N [kN] 7,6 9,5 14,3 19,0 23,9
1)
Solicitare la traciune admis (zon ntins) N [kN] 4,3 5,7 7,6 9,5 16,6
1)
Solicitare la forfecare admis V [kN] 6,3 9,7 14,3 26,9 41,7
Distan necesar fa de margine Ccr [cm] 11 13 15 18 24
Distan necesar ntre axe Scr [cm] 22 26 30 36 48
2)
Distan minim fa de margini Cmin [cm] 5 6 7 8 10
2)
Distan minim ntre axe Smin [cm] 5 6 7 8 10
Diametru gaur do [mm] 10 12 14 18 22
Adncime gaur h1 [cm] 6 7 8 9,5 12,5
Grosime min. element de construcie hmin [cm] 11 13 15 18 24
Gaur de trecere [mm] 11 13 15 19 23
Moment de strngere Tinst [Nm] 12 23 40 70 130
Deschidere cheie SW [mm] 13 17 19 24 30
1)
Sarcinile admisibile sunt valabile pentru fixri individuale la distan fa de margini, cu armtur dens, coeficient parial de siguran al aplicrii forei 1,4
2)
Sarcinile admisibile trebuie reduse n conformitate cu aprobarea ETA
Informaii suplimentare putei gsi n Manualul tehnicii de ancorare Hilti, sau pe Internet la adresa www.hilti.ro.
HIT-HY 150 Mortar de injecie HIT-TZ Tij ancor injectat
Ancore pentru sarcini mari / Chimice
1 2 3 4 5a 5b 6
HY 150
HY 150
HY 150
HY 150
tcure
~
0
,
5

h
n
o
m
h
n
o
m
h
n
o
m
h
n
o
m
T
e
h
n
i
c
a

a
n
c
o
r

r
i
i
138
HIT-HY 150 Mortar de injecie
330 2 Mixere HIT-HY 150/330 334539 1
500 2 Mixere HIT-HY 150/500 338973 20
HIT-TZ Tije de ancorare
Execuie: cu piuli i aib de susinere
Material: oel 6.8, zincat galvanic
10 60 55 15 82 HIT-TZ M 8 55/15 284796 40
10 60 55 40 107 HIT-TZ M 8 55/40 284797 40
12 70 65 15 93 HIT-TZ M 10 65/15 337476 40
12 70 65 40 118 HIT-TZ M 10 65/40 337477 40
14 80 75 15 106 HIT-TZ M 12 75/15 337478 20
14 80 75 30 121 HIT-TZ M 12 75/30 284801 20
14 80 75 50 141 HIT-TZ M 12 75/50 337479 20
18 95 90 25 136 HIT-TZ M 16 90/25 337480 10
18 95 90 60 171 HIT-TZ M 16 90/60 337481 10
22 125 120 30 174 HIT-TZ M 20 120/30 337482 6
22 125 120 60 204 HIT-TZ M 20 120/60 337483 6
HIT-RTZ Tije de ancorare
Execuie: cu piuli i aib de susinere
Material: oel inoxidabil A4, indice material 1.4404
10 60 55 15 HIT-RTZ M 8 55/15 284798 40
10 60 55 40 HIT-RTZ M 8 55/40 284799 40
12 70 65 15 HIT-RTZ M 10 65/15 337490 40
12 70 65 40 HIT-RTZ M 10 65/40 337491 40
14 80 75 15 HIT-RTZ M 12 75/15 337492 20
14 80 75 30 HIT-RTZ M 12 75/30 337817 20
14 80 75 50 HIT-RTZ M 12 75/50 337493 20
18 95 90 25 HIT-RTZ M 16 90/25 337494 10
18 95 90 60 HIT-RTZ M 16 90/60 337495 10
22 125 120 30 HIT-RTZ M 20 120/30 337496 6
22 125 120 60
82
107
93
118
106
121
141
136
171
174
204 HIT-RTZ M 20 120/60 337497 6
Ancore pentru sarcini mari / Chimice
Coninut
(ml)
Cod
comand
Nr. articol Buc. /
ambalaj
Inclusiv
x gaur
d (mm)
0
Cod
comand
Nr. articol Buc. /
ambalaj
Adncime
gaur h (mm)
1
Adncime de
pozare h (mm)
nom
nlime de
fixare t (mm)
fix
Lungime
tij (mm)
x gaur
d (mm)
0
Cod
comand
Nr. articol Buc. /
ambalaj
Adncime
gaur h (mm)
1
Adncime de
pozare h (mm)
nom
nlime de
fixare t (mm)
fix
Lungime
tij (mm)
Set dinamic
Cod
comand
Nr. articol Buc./
ambalaj
Dynamic Set M10* 369201 2
Dynamic Set M12 369202 2
Dynamic Set M16 369203 2
Dynamic Set M20 369204 2
1)
HIT-HY 150/330 334539 1
* timp de livrare la cerere
1)
pentru umplerea fantei inelare dintre tija de ancorare i gaura de trecere a plcii de ancorat
Ancor cu autotiere HDA qa, ancor chimic HVZ 8
141
qs HVZ / HDA Seturi dinamice
n
n
n
n
Combinarea ancorelor verificate HDA + HVZ cu setul dinamic.
Ancoraj sigur al sarcinilor dinamice
Montaj simplu i rapid
Nou concept de dimensionare
Date tehnice pentru set dinamic HDA
HDA-dynamic inclusiv set dinamic M10 M12 M16
Numr aprobare Z-21, 1-1693 din 04.09.2001
Material de ancorare Beton cu i fr fisuri C20 / 25, resp. B25
HDA-P HDA-T HDA-P HDA-T HDA-P HDA-T
ncrcare admis Npt diblu individual la dist. fa de margine [kN] 6,7 11,8 22,9
ncrcare admis Vpt diblu individual la dist. fa de margine [kN] 2,0 6,3 4,5 11,3 6,1 17,3
1)
Distana ntre axe Scr [cm] 30 37,5 57
1)
Distana fa de margine [cm] 15 19 28,5
1)
Distana minim ntre axe Smin[cm] 10 12,5 19
1)
Distana minim fa de margine Cmin[cm] 8 10 15
Adncime de ancorare hef [cm] 10 12,5 19
Grosime minim element de construcie hmin [cm] 20 25 38
Cuplu de torsiune la ancorare [Nm] 50 80 120
Seturi dinamice pentru sarcini mari
HVU-TZ Cartu pentru ancor chimic
HAS-TZ / HAS-R TZ Tij de ancorare
HDA P Ancor cu autotiere
Compus din aib de umplere, aib tip calot, piuli i piuli de siguran
Extras din condiiile de utilizare ale aprobrilor Z-21, 1-1693 (HDA-dynamic) conform procedurii de dimensionare A (ETAG anexa C).
Sarcinile sunt valabile pentru un singur diblu fr influene marginale, n beton C20 / 25, resp. B25. V rugm s luai valorile caracteristice de sarcin menionate n aprobare.
1) Dac distana fa de margini este mai mic dect 10xhef, respectiv se efectueaz o fixare multipl, ncrcrile se vor stabili conform aprobrii Z-21, 1-1693: Programul Hilti de dimensionare a diblurilor
Date tehnice pentru set dinamic HVZ
HVZ-dynamic inclusiv set dinamic M10x75 M12x95 M16x105 M16x125
Numr aprobare Z-21, 3-1692 din 01.04.2003
Material de ancorare Beton cu i fr fisuri C20 / 25, resp. B25
ncrcare admis Npt diblu individual la dist. fa de margine [kN]
3,3
7,4
6,3
12,3
11,1
14,3
11,1
18,5
ncrcare admis Vpt diblu individual la dist. fa de margine [kN]
22,5 28,5 31,5 37,5
1)
Distana ntre axe Scr [cm]
11,5 14,5 16 19
1)
Distana fa de margine [cm]
6 7,5 8,5 8,5
1)
Distana minim ntre axe Smin[cm]
6 7,5 8,5 8,5
1)
Distana minim fa de margine Cmin[cm]
7,5 9,5 10,5 12,5 Adncime de ancorare hef [cm]
15 19 21 25 Grosime minim element de construcie hmin [cm]
40 50 90 90 Cuplu de torsiune la ancorare [Nm]
Extras din condiiile de utilizare ale aprobrilor Z-21, 3-1692 (HVZ-dynamic) conform procedurii de dimensionare A (ETAG anexa C).
Sarcinile sunt valabile pentru un singur diblu fr influene marginale, n beton C20 / 25, resp. B25. v rugm s luai valorile caracteristice de sarcin menionate n aprobare.
1) Dac distana fa de margini este mai mic dect 10xhef, respectiv se efectueaz o fixare multipl, ncrcrile se vor stabili conform aprobrii Z-21, 1-1693: Programul Hilti de dimensionare a diblurilor
T
e
h
n
i
c
a

a
n
c
o
r

r
i
i
142
Avantaje:
Date tehnice
Extras din aprobarea ETA: ETA-02/0042
HSL-3 M8 M10 M12 M16 M20 M24
Material de ancorare Beton C20/25
1)
Sarcin traciune adm. (zon comp.) N [kN] 11,1 14,0 17,2 24,0 33,5 44,1
1)
Sarcin traciune adm. (zon ntins) N [kN] 4,8 7,6 12,3 17,1 24,0 31,5
1)
Sarcin forfecare admis V [kN] 17,8 28,1 41,0 57,8 81,1 101,4
Distan necesar fa de margine Ccr [cm] 9 10,5 12 15 18,8 22,5
Distan necesar ntre axe Scr [cm] 18 21 24 30 37,5 45
2)
Distan minim fa de margini Cmin [cm] 6 7 8 10 15 15
2)
Distan minim ntre axe Smin [cm] 6 7 8 10 12,5 15
Diametru gaur do [mm] 12 15 18 24 28 32
Adncime gaur h1 [cm] 8 9 10,5 12,5 15,5 18
Grosime min. element de construcie hmin [cm] 12 14 16 20 25 30
Gaur de trecere [mm] 14 17 20 26 31 35
Moment strngere Tinst [Nm] HSL-3/HSL-3G 25/20 50/35 80/60 120/80 200/160 250
Deschidere cheie SW [mm] 13 17 19 24 30 36
qd HSL-3 Ancor pentru sarcini mari
Siguran pentru sarcini mari
Material: Aprobare Protecie antifoc
nBeton cu i fr fisuri ETA-02/0042
Utilizare:
nPentru sarcini mari, de ex. stlpi, maini , echipamente
HSL-3 Ancor pentru sarcini mari
Execuie:
nCu urub hexagonal i aib suport
Material:
n
n
Oel , zincat galvanic, urub filetat.
Clas de rezisten a urubului 8.8
5 12 80 60 14 13 HSL-3 M8/5 371774 40
20 12 80 60 14 13 HSL-3 M8/20 371775 40
40 12 80 60 14 13 HSL-3 M8/40 371776 40
5 15 90 70 17 17 HSL-3 M10/5 371777 20
20 15 90 70 17 17 HSL-3 M10/20 371778 20
40 15 90 70 17 17 HSL-3 M10/40 371779 20
5 18 105 80 20 19 HSL-3 M12/5 371780 20
25 18 105 80 20 19 HSL-3 M12/25 371781 20
50 18 105 80 20 19 HSL-3 M12/50 371782 10
10 24 125 100 26 24 HSL-3 M16/10 371783 10
25 24 125 100 26 24 HSL-3 M16/25 371784 10
50 24 125 100 26 24 HSL-3 M16/50 371785 10
10 28 155 125 31 30 HSL-3 M20/10 371786 6
30 28 155 125 31 30 HSL-3 M20/30 371787 6
60 28 155 125 31 30 HSL-3 M20/60 371788 6
10 32 180 150 35 36 HSL-3 M24/10 371789 4
30 32 180 150 35 36 HSL-3 M24/30 371790 4
60 32 180 150 35 36 HSL-3 M24/60 371791 4
Ancore pentru sarcini mari
/ Metalice
IBMB 3027/027-5
Indicaii de montaj:
Marcajul
adncimii
de pozare
n
n
n
n
Cele mai bune valori de sarcin la ncrcri transversale i de
traciune
Manon masiv, nchis, al diblului
Element de material plastic integrat:
- mpiedic rotirea accidental
- prindere strns a elementului de racord
Este posibil tensionarea ulterioar
1)
Sarcinile admisibile sunt valabile pentru fixri individuale la distan fa de margini, cu armtur dens, coeficient parial de siguran al aplicrii forei 1,4
2)
Sarcinile admisibile trebuie reduse n conformitate cu aprobarea ETA
Informaii suplimentare putei gsi n Manualul tehnicii de ancorare Hilti, sau pe Internet la adresa www.hilti.ro.
nlime
de fixare
t (mm)
fix
Adncime
min. gaur
h (mm)
1
Adncime
efectiv de
ancorare h (mm)
ef
Cod
comand
x nominal
burghiu (mm)
d (mm)
0
Nr. articol Buc. /
ambalaj
Gaur
de trecere
(mm)
Deschidere
cheie
SW (mm)
143
HSL-3-G Ancor pentru sarcini mari
Execuie:
nCu tij filetat, aib suport i piuli
Material:
nOel, zincat galvanic.
5 12 80 60 14 13 HSL-3-G M8/5 371792 40
20 12 80 60 14 13 HSL-3-G M8/20 371793 40
40 12 80 60 14 13 HSL-3-G M8/40 371794 40
100 12 80 60 14 13 HSL-3-G M8/100 371829 20
5 15 90 70 17 17 HSL-3-G M10/5 371795 20
20 15 90 70 17 17 HSL-3-G M10/20 371796 20
40 15 90 70 17 17 HSL-3-G M10/40 371797 20
100 15 90 70 17 17 HSL-3-G M10/100 371830 20
5 18 105 80 20 19 HSL-3-G M12/5 371798 20
25 18 105 80 20 19 HSL-3-G M12/25 371799 20
50 18 105 80 20 19 HSL-3-G M12/50 371800 10
100 18 105 80 20 19 HSL-3-G M12/100 371831 10
10 24 125 100 26 24 HSL-3-G M16/10 371801 10
25 24 125 100 26 24 HSL-3-G M16/25 371802 10
50 24 125 100 26 24 HSL-3-G M16/50 371803 10
100 24 125 100 26 24 HSL-3-G M16/100 371832 10
10 28 155 125 31 30 HSL-3-G M20/10 371804 6
30 28 155 125 31 30 HSL-3-G M20/30 371805 6
60 28 155 125 31 30 HSL-3-G M20/60 371806 6
100 28 155 125 31 30 HSL-3-G M20/100 371833 6
30 32 180 150 35 36 HSL-3-G M24/30 324930 4
Ca execuie special, sunt posibile HSL-3-G cu alte nlimi de fixare i adncimi de ancorare.
Preurile i timpul de livrare se comunic la cerere.
Piulie inelare*
zincate, DIN 582, calitate C15, ncrcare conform DIN 582
20 36 1,4 0,95 Ri M 8 58202 50
25 45 2,3 1,7 Ri M 10 58203 50
30 54 3,4 2,4 Ri M 12 58204 50
35 63 7,0 5,0 Ri M 16 58206 50
40 72 12,0 8,3 Ri M 20 58207 25
50 90 18,0 12,7 Ri M 24 58208 20
* nu sunt permise ncrcrile transversale pe axa inelului.
Ancore pentru sarcini mari
/ Metalice
Marcajul
adncimii
de pozare
nlime
de fixare
t (mm)
fix
Adncime
min. gaur
h (mm)
1
Adncime
efectiv de
ancorare h (mm)
ef
Cod
comand
x nominal
burghiu (mm)
d (mm)
0
Nr. articol Buc. /
ambalaj
Gaur
de trecere
(mm)
Deschidere
cheie
SW (mm)
x interior
inel (mm)
Pentru o
piuli (kN)
Pentru 2 piulie
n total (kN)
Cod
comand
x exterior
inel (mm)
Nr. articol Buc. /
ambalaj
T
e
h
n
i
c
a

a
n
c
o
r

r
i
i
144
Avantaje:
n
n
n
Nu este necesar o cheie
dinamometric pentru montaj
Siguran foarte mare a
montajului
Control optic al montajului
Avantaje:
nurubul cu cap hexagonal interior face posibil montajul n condiii
de spaiu redus
HSL-3-B Ancor pentru sarcini mari
Execuie:
nCu piuli de control: la atingerea momentului de
strngere prestabilit piulia roie de control se
desprinde prin forfecare. Apoi devine vizibil o plomb
din material plastic verde, care indic faptul c diblul
este ancorat perfect.
Material:
HSL-3-SH Ancor pentru sarcini mari
Execuie:
nCu urub cu cap hexagonal interior
Utilizare:
nPentru sarcini mari, special pentru montaje n care din raiuni de
spaiu nu se pot utiliza cheia inelar sau cheia fix, de ex. montajul
de ine.
Material:
n
n
Oel, zincat galvanic, , urub filetat
Clas de rezisten a urubului 8.8
5 18 105 80 20 24 HSL-3-B M12/5 371807 20
25 18 105 80 20 24 HSL-3-B M12/25 371808 20
50 18 105 80 20 24 HSL-3-B M12/50 371809 10
10 24 125 100 26 30 HSL-3-B M16/10 371810 10
25 24 125 100 26 30 HSL-3-B M16/25 371811 10
50 24 125 100 26 30 HSL-3-B M16/50 371812 10
10 28 155 125 31 36 HSL-3-B M20/10 371813 6
30 28 155 125 31 36 HSL-3-B M20/30 371814 6
60 28 155 125 31 36 HSL-3-B M20/60 371815 6
10 32 180 150 35 41 HSL-3-B M24/10 371816 4
30 32 180 150 35 41 HSL-3-B M24/30 371817 4
60 32 180 150 35 41 HSL-3-B M24/60 371818 4
5 12 80 60 14 6 HSL-3-SH M8/5 377341 60
20 15 90 70 17 8 HSL-3-SH M10/20 377342 40
25 18 105 80 20 10 HSL-3-SH M12/25 377343 20
Ancore pentru sarcini mari
/ Metalice
nOel zincat galvanic, urub filetat
Clas de rezisten a urubului 8.8.
Marcajul
adncimii
de pozare
nlime
de fixare
t (mm)
fix
Adncime
min. gaur
h (mm)
1
Adncime
efectiv de
ancorare h (mm)
ef
Cod
comand
x nominal
burghiu (mm)
d (mm)
0
Nr. articol Buc. /
ambalaj
Gaur
de trecere
(mm)
Deschidere
cheie
SW (mm)
nlime
de fixare
t (mm)
fix
Adncime
min. gaur
h (mm)
1
Adncime
efectiv de
ancorare h (mm)
ef
Cod
comand
x nominal
burghiu (mm)
d (mm)
0
Nr. articol Buc. /
ambalaj
Gaur
de trecere
(mm)
Deschidere
cheie
SW (mm)
145
Avantaje:
Nu exist pericol de mpiedicare, aspect optic plcut, datorit
montajului la acelai nivel cu suprafaa.
HSL-3-SK Ancor pentru sarcini mari
Execuie:
nCu urub cu cap necat (similar DIN 7991)
Utilizare:
nAncorri pt. sarcini mari la acelai nivel cu suprafaa elementului montat.
Material:
nOel, zincat galvanic
10 12 75 60 14 24 6 6 HSL-3 M 8/10 SK 371825 40
20 12 80 60 14 24 6 6 HSL-3 M 8/20 SK 371826 40
20 15 90 70 17 27 8 6 HSL-3 M10/20 SK 371827 20
25 18 100 80 20 33 10 7,5 HSL-3 M12/25 SK 371828 20
90
HSL-G-R Ancor pentru sarcini mari, inoxidabil
Execuie: cu tij filetat, aib suport i piuli, material - oel inoxidabil A4,
(indice material 1.4401)
20 12 80 60 14 13 HSL-G-R M8/20 67920 40
20 15 90 70 17 17 HSL-G-R M10/20 67922 20
25 18 105 80 20 19 HSL-G-R M12/25 67924 20
25 24 125 100 26 24 HSL-G-R M16/25 67926 10
30 28 155 125 31 30 HSL-G-R M20/30 67928 6
Nu este inclus n aprobarea ETA
Fixri speciale sarcini mari
GW Vinclu pentru schel, pentru schele n consol
Sistem de ancoraj al schelei
Pentru beton ncepnd de la C 20/25
GW 160-100 Vinclu pentru schel 1
HSL-3-B M 12/50 10
Pentru geometria gurii a se vedea mai sus.
Pentru utilizri pe suprafee din crmid plin v rugm s v adresai tehnicienilor notri.
Ancore pentru sarcini mari
/ Metalice / fixri speciale
h
d
1
nl. max.
de fixare
t (mm)
fix
Adncime
min. gaur
h (mm)
1
Adncime efectiv
de ancorare
h (mm)
ef
Cod
comand
xnominal
burghiu (mm)
d (mm)
0
Nr. articol Buc. /
ambalaj
Gaur
de trecere
(mm)
x cap
d (mm)
1
Gaur interioar
hexagonal
SW (mm)
nlime
cap h (mm)
nl. max.
de fixare
t (mm)
fix
Cod
comand
Adncime
min. gaur
h (mm)
1
58751
371809
Nr. articol
Adncime efectiv
de ancorare
h (mm)
ef
Cod
comand
xnominal
burghiu (mm)
d (mm)
0
Nr. articol Buc. /
ambalaj
Buc. /
ambalaj
Gaur
de trecere
(mm)
Deschidere
cheie
SW (mm)
T
e
h
n
i
c
a

a
n
c
o
r

r
i
i
HDA - Dimensions


HDA-T
cut-out for setting /
removal tool, turned
through 90 d
S1 d
S 2 d
S 3
d
B
d
C
AF
S
l
B
l



HDA-P
cut-out for setting /removal
tool, turned through 90 d
S1
d
S 2 d
S 3
d
B
d
C
AF
S
l
B
l



Anchor
t
fix

[mm]
l
B
[mm]
Length
code
l
S
[mm]
AF
[mm]
d
S1
[mm]
d
S2
[mm]
d
S3
[mm]
d
C
[mm]
d
B
[mm]
HDA-P/PR/PF20-M10*100/20 20 150 I 100 17 19 16.8 18.5 19.5 10
HDA-T/TR/TF 20-M10*100/20 20 150 I 120 17 19 16.8 18.5 19.5 10
HDA-P/PR/PF 22-M12*125/30 30 190 L 125 19 21 18.8 20.5 21.4 12
HDA-P/PR/PF 22-M12*125/50 50 210 N 125 19 21 18.8 20.5 21.4 12
HDA-T/TR/TF 22-M12*125/30 30 190 L 155 19 21 18.8 20.5 21.4 12
HDA-T /TR/TF22-M12*125/50 50 210 N 175 19 21 18.8 20.5 21.4 12
HDA-P/PR/PF 30-M16*190/40 40 275 R 190 24 29 26 29 29 16
HDA-P/PR/PF 30-M16*190/60 60 295 S 190 24 29 26 29 29 16
HDA-T/TR/TF 30-M16*190/40 40 275 R 230 24 29 26 29 29 16
HDA-T/TR/TF 30-M16*190/60 60 295 S 250 24 29 26 29 29 16
HDA-P 37-M20*250/50 50 360 V 350 30 35 32 35 36 20
HDA-P 37-M20*250/100 100 410 X 250 30 35 32 35 36 20
HDA-T 37-M20*250/50 50 360 V 300 30 35 32 35 36 20
HDA-T 37-M20*250/100 100 410 X 350 30 35 32 35 36 20






HDA - Dimensions



Stop bit



Stop bit t

[mm] d
0
[mm] connection end
TE-C-HDA-B 20*100 107 20 TE-C
TE-C-HDA-B 20*120 127 20 TE-C
TE-C-HDA-B 22*125 134.5 22 TE-C
TE-C-HDA-B 22*155 164.5 22 TE-C
TE-C-HDA-B 22*175 184.5 22 TE-C
TE-Y-HDA-B 30*190 203 30 TE-Y
TE-Y-HDA-B 30*230 243 30 TE-Y
TE-Y-HDA-B 30*250 263 30 TE-Y
TE-Y-HDA-B 37*250 261 37 TE-Y
TE-Y-HDA-B 37*300 311 37 TE-Y
TE-Y-HDA-B 37*350 361 37 TE-Y





Setting tool
connection end
d


Setting tool d
0
[mm] connection end
TE-C-HDA-ST 20-M10 20 TE-C
TE-C-HDA-ST 22-M12 22 TE-C
TE-Y-HDA-ST 30-M16 30 TE-Y
TE-Y-HDA-ST 37-M20 37 TE-Y

working length, t
connection end
d
0

HIT-RE 500 injection adhesive with rebar
Issue 2005 245
3
Features: - base material: concrete
- injection system with high loading capacity
- good performance in diamond drilled holes
- good performance in wet holes
- suitable for water saturated concrete
- large diameter applications
- long working time at elevated temperatures
- odourless epoxy resin
- no expansion forces in base material
- small edge distance and anchor spacing
- clean and easy handling
Material:
Rebar:
- Type BSt 500 according to DIN 488 (See also
Euronorm 82-79.). For differing rebars, consult
your Hilti advisory service.
Cartridge:
- Foil pack: 330 ml, 500ml
- Jumbo cartridge: 1100 ml
Dispenser:
- MD2000, BD2000, P3000 F, MD2500, P3500 F,
P5000 HY, HIT P-8000 D
Basic loading data (for a single anchor): HIT-RE 500 with rebar section
All data on this section applies to For detailed method, see page 248 253.
- concrete: See table below.
- correct setting (See setting operations page 247)
- no edge distance, spacing and other influences
Rebar embedment depth [mm]: concrete = C20/25
Rebar diameter [mm] C 8 C 10 C 12 C 14 C 16 C 20 C 25 C 28 C 32 C 36 C 40
Nominal anch. depth 80 90 110 125 125 170 210 270 300 330 360
Mean ultimate resistance, R
u,m
[kN]: concrete = C20/25
Rebar diameter [mm] C 8 C 10 C 12 C 14 C 16 C 20 C 25 C 28 C 32 C 36 C 40
Tensile, Concrete: N
Ru,m
33.4 46.9 68.8 91.3 104.3 177.3 273.8 344.4 407.2 462.2 515.7
Tensile, Steel: N
Ru,m
29.9 46.7 67.2 91.4 119.4 186.6 291.6 365.8 477.7 604.6 746.4
Shear, V
Ru,m
17.9 28.1 40.4 55.0 71.8 112.3 175.0 219.2 286.3 384.5 447.9
Characteristic resistance, R
k
[kN]: concrete = C20/25
Rebar diameter [mm] C 8 C 10 C 12 C 14 C 16 C 20 C 25 C 28 C 32 C 36 C 40
Tensile, Concrete: N
Rk
25.1 35.3 51.8 68.7 78.5 133.5 206.2 258.9 304.6 347.1 389.1
Tensile, Steel: N
Rk
25.1 39.3 56.5 77.0 100.5 157.1 245.4 307.9 402.1 508.9 628.3
Shear, V
Rk
16.7 26.0 37.4 50.9 66.5 104.0 162.0 203.0 265.1 356.0 414.6
HIT-RE 500 foil pack, mixer
Rebar section
Concrete
Close edge
distance /
spacing
Fire
resistance
Hilti Anchor
programme
non-cracked concrete
246 Issue 2005
HIT-RE 500 injection adhesive with rebar
h
1
h
d
0
0

d
/
Following values according to the
Concrete Capacity Method
Design resistance, R
d
[kN]: concrete, f
ck,cube
= 25 N/mm
2
Rebar diameter [mm] C 8 C 10 C 12 C 14 C 16 C 20 C 25 C 28 C 32 C 36 C 40
Tensile, N
Rd
13.9 19.7 28.8 38.2 43.7 74.2 114.5 143.9 169.2 192.8 216.1
Shear, V
Rd
11.1 17.3 24.9 33.9 44.3 69.3 108.0 135.3 176.7 237.3 276.4
Recommended load, L
rec
[kN]: concrete, f
ck,cube
= 25 N/mm
2
Rebar diameter [mm] C 8 C 10 C 12 C 14 C 16 C 20 C 25 C 28 C 32 C 36 C 40
Tensile, N
Rec
9.9 14.1 20.6 27.3 31.2 53.0 81.8 102.8 120.9 137.7 154.4
Shear, V
Rec
7.9 12.4 17.8 24.2 31.6 49.5 77.1 96.6 126.2 169.5 197.4
Setting details
Rebar diameter C [mm] C 8 C 10 C 12 C 14 C 16 C 20 C 25 C 28 C 32 C 36 C 40
d
0
[mm] Drill bit diameter 10-12 12-14 16-18 18-20 20-22 25-28 30-32 35-37 39-42 42-48 48-52
h
1
[mm] Hole depth 82 93 115 130 130 175 215 275 305 335 365
h
nom
[mm] Nominal anchorage depth 80 90 110 125 125 170 210 270 300 330 360
h
min
[mm]
Min. thickness of base
material
100 120 140 170 170 220 270 340 380 410 450
ml 3-6 4-9 13-20 17-25 19-29 40-64 60-84 118-155 162 147 206
Filling volume
1)
trigger pulls 1 1-2 2-4 3-5 4-6 8-13 12-17 24-31 32 30 41
TE- 1..18M 5..18M 15..35 25..55 35..55 55..76 55..76 55..76 55..76 55..76 55..76 Recommended drilling
system Diamond drill. DD EC-1, DD 100 DD 100, DD 130, DD 160
1)
Holes must be filled approx. 2/3 rds.
Temprature of the
basematerial:
Working time in which rebar
can be inserted and adjusted
Curing time before rebar can
be fully loaded
40C
30C
20C
10C
0C
-5C
12 min.
20 min.
30 min.
2 hours
3 hours
4 hours
4 hours
8 hours
12 hours
24 hours
50 hours
72 hours
less than -5C not allowed
The foil pack temperature must be at least +5C.
Installation equipment
- appropriate drill bit (diamond core bit)
- dispenser (MD 2000, BD 2000, P3000 F, P5000 HY, HIT P-8000 D)
- blow-out pump
- cleaning brushes
min
h
nom
Issue 2005 247
3
HIT-RE 500 injection adhesive with rebar
Setting operations
HIT-RE 500 injection adhesive with rebar
248 Issue 2005
Anchor geometry and mechanical properties
Rebar C [mm] C 8 C 10 C 12 C 14 C 16 C 20 C 25 C 28 C 32 C 36 C 40
C [mm] Nominal rebar diameter 8 10 12 14 16 20 25 28 32 36 40
A
s
[mm] Stressed cross-section 50.3 78.5 113.1 153.9 201.1 314.2 490.9 615.8 804.2 1017.9 1256.6
f
uk
[N/mm]
Nominal tensile
strength
550
f
yk
[N/mm] Yield strength 500
Detailed design method - Hilti CC
Caution: In view of the high loads transferable with HIT-RE 500, it must be verified by the user that the load
acting on the concrete structure, including the loads introduced by the anchor fastening, do not
cause failure, e.g. cracking, of the concrete structure.
TENSION
The design tensile resistance of a single anchor
is the lower of
N
Rd,c
: concrete cone/pull-out resistance
N
Rd,s
: steel resistance
N
Rd,c
: Concrete cone/pull-out resistance
W.sat Temp N R, N A, N B, T
o
c Rd, c Rd,
f f f f f f N N
N
0
Rd,c
: Concrete cone/pull-out resistance
- concrete compressive strength, f
ck,cube
= 25 N/mm
2
Rebar C [mm] 8 10 12 14 16 20 25 28 32 36 40
N
o
Rd,c
1)
[kN] Concrete 13.9 19.7 28.8 38.2 43.7 74.2 114.5 143.9 169.2 192.8 216.1
h
nom
[mm] Nominal anchorage depth 80 90 110 125 125 170 210 270 300 330 360
1)
The design tensile resistance is calculated from the characteristic tensile resistance, N
o
Rk,c
, by N
o
Rd,c
= N
o
Rk,c
/
Mc,N
, where the partial
safety factor,
Mc,N
, is 1.8.
(The Hilti CC method is a simplified version of ETAG Annex C.)
anchorage depth addtional length
according to application
d
N
c
s
h
rec,c/s
HIT-RE 500 injection adhesive with rebar
Issue 2005 249
3
f
T
: Influence of anchorage depth
f
B,N
: Influence of concrete strength
Concrete strength
designation
(ENV 206)
Cylinder compressive
strength,
f
ck,cyl
[N/mm]
Cube compressive
strength,
f
ck,cube
[N/mm]
f
B,N
C20/25 20 25 1
C25/30 25 30 1.03
C30/37 30 37 1.06
C35/45 35 45 1.10
C40/50 40 50 1.13
C45/55 45 55 1.15
C50/60 50 60 1.18
Concrete cylinder:
Height 30cm
Diameter 15cm
Concrete cube:
side length 15 cm
Concrete test specimen geometry
f
A,N
: Influence of anchor spacing
Rebar size Anchor
spacing,
s [mm]
8 10 12 14 16 20 25 28 32 36 40
40 0.63
45 0.64 0.63
50 0.66 0.64
55 0.67 0.65 0.63
60 0.69 0.67 0.64
65 0.70 0.68 0.65 0.63 0.63
70 0.72 0.69 0.66 0.64 0.64
80 0.75 0.72 0.68 0.66 0.66
90 0.78 0.75 0.70 0.68 0.68 0.63
100 0.81 0.78 0.73 0.70 0.70 0.65
120 0.88 0.83 0.77 0.74 0.74 0.68 0.64
140 0.94 0.89 0.82 0.78 0.78 0.71 0.67 0.63
160 1.00 0.94 0.86 0.82 0.82 0.74 0.69 0.65 0.63
180 1.00 0.91 0.86 0.86 0.76 0.71 0.67 0.65 0.64 0.63
200 0.95 0.90 0.90 0.79 0.74 0.69 0.67 0.65 0.64
220 1.00 0.94 0.94 0.82 0.76 0.70 0.68 0.67 0.65
250 1.00 1.00 0.87 0.80 0.73 0.71 0.69 0.67
280 0.91 0.83 0.76 0.73 0.71 0.69
310 0.96 0.87 0.79 0.76 0.73 0.72
340 1.00 0.90 0.81 0.78 0.76 0.74
390 0.96 0.86 0.83 0.80 0.77
420 1.00 0.89 0.85 0.82 0.79
450 0.92 0.88 0.84 0.81
480 0.94 0.90 0.86 0.83
540 1.00 0.95 0.91 0.88
600 1.00 0.95 0.92
660 1.00 0.96
720 1.00
nom
act
T
h
h
f Limits to actual anchorage, h
act
: h
nom
s h
act
s2.0 h
nom
|
|
.
|

\
| -
-
200
25 f
1 f
cube , ck
N , B
Limits:
25 N/mm s f
ck,cube
s 60 N/mm
nom
N , A
h 4
s
5 . 0 f

-
Limits: s
min
s s s s
cr,N
s
min
= 0,5h
nom
s
cr,N
= 2,0h
nom
HIT-RE 500 injection adhesive with rebar
250 Issue 2005
f
R,N
: Influence of edge distance
Rebar size Edge
distance,
c [mm]
8 10 12 14 16 20 25 28 32 36 40
40 0.64
45 0.69 0.64
50 0.73 0.68
55 0.78 0.72 0.64
60 0.82 0.76 0.67
65 0.87 0.80 0.71 0.65 0.65
70 0.91 0.84 0.74 0.68 0.68
80 1.00 0.92 0.80 0.74 0.74
90 1.00 0.87 0.80 0.80 0.66
100 0.93 0.86 0.86 0.70
110 1.00 0.91 0.91 0.75 0.66
120 0.97 0.97 0.79 0.69
140 1.00 1.00 0.87 0.76 0.65
160 0.96 0.83 0.71 0.66
180 1.00 0.90 0.76 0.71 0.67 0.64
210 1.00 0.84 0.78 0.74 0.70
240 0.92 0.86 0.80 0.76
270 1.00 0.93 0.87 0.82
300 1.00 0.93 0.88
330 1.00 0.94
360 1.00
f
Temp
: Influence of base material temperature
Anchor setting: The Hilti HIT-RE 500 bond strength reduces when the anchor is set, cures and in service in a
base material temperature range from 5 to +5C. Hilti HIT-RE 500 adhesive shows a post curing effect. When
the adhesive warms up to above +5C, the bond will reach its full performance.
Service life: Base material temperatures above 50C will lead to a decrease in Hilti HIT-RE 500 bond strength.
Base material
temperature
f
Temp
anchor
setting
f
temp
service life
-5 C 0.8 1.0
0 C 0.9 1.0
5C 1.0 1.0
50C - 1.0
60 C - 0.85
70 C - 0.62
80 C - 0.5
Note:
In case of an anchor fastening, which is made in base material at a temperature below +5C and in service at a
temperature over 50C, only one influencing factor of the lower value should be applied.
f
W.sat
: Influence of water saturated concrete
0.7 f
W.sat

Note:
The reduction shall only be applied, if the anchor is setted into water-saturated concrete, e.g. concrete members
in water, filled water tanks, predrilled holes filled with water for more than 3 days. The reduction does not apply,
if the concrete is subjected to short term water influence, e.g. diamond-cored holes.
nom
N , R
h
c
72 . 0 28 . 0 f -
Limits c
min
s c s c
cr,N
c
min
= 0,5 h
nom
c
cr,N
= 1,0 h
nom
Note: If more than 3 edges
are smaller than c
cr,N
, consult
your Hilti technical advisory
service.
HIT-RE 500 injection adhesive with rebar
Issue 2005 251
3
N
Rd,s
: Steel design tensile resistance
Rebar C [mm] 8 10 12 14 16 20 25 28 32 36 40
N
Rd,s
1)
[kN] 20.9 32.7 47.1 64.1 83.8 130.9 204.5 256.6 335.1 424.1 523.6
1)
The design tensile resistance is calculated from the characteristic tensile resistance, N
Rk,s
, by N
Rd,s
= A
s
f
uk
/
Ms,N
, where the partial safety
factor,
Ms,N
, for rebar sections, type BSt 500, is 1.32.
N
Rd
: System design tensile resistance
N
Rd
= lower of N
Rd,c
and N
Rd,s
Combined loading: Only if tensile load and shear load applied (See page 31 and section 4 Examples).
Detailed design method - Hilti CC
SHEAR
The design shear resistance of a single
anchor is the lower of
V
Rd,c
: concrete edge resistance
V
Rd,s
: steel resistance
V
Rd,c
: Concrete edge design resistance
The lowest concrete edge design resistance must be calculated. All near edges must be checked (not only the
edge in the direction of shear). The direction of shear load is accounted for by the factor f
,V
.
V , V , AR V , B
0
c , Rd c , Rd
f f f V V


V
0
Rd,c
: Concrete edge design resistance
- concrete compressive strength, f
ck,cube
= 25 N/mm
2
- at minimum edge distance
min
c
Rebar C [mm] 8 10 12 14 16 20 25 28 32 36 40
V
o
Rd,c
1)
[kN] 2.0 3.6 5.0 7.1 7.3 12.5 18.8 30.2 37.7 45.0 54.0
c
min
[mm] Min. edge distance 40 45 55 65 65 85 105 135 150 165 180
1)
The design shear resistance is calculated from the characteristic shear resistance, V
o
Rk,c
, by V
o
Rd,c
= V
o
Rk,c
/
Mc,V
, where the partial
safety factor,
Mc,V
, is 1.5.
(The Hilti CC method is a simplified version of ETAG Annex C.)
V
c
s
rec,c/s
c
>
1
.5
c
2
c
>
1
.
5
c
2
h
>
1
.5
c
Note: If the conditions for h and c
2
are not met,
consult your Hilti technical advisory service.
HIT-RE 500 injection adhesive with rebar
252 Issue 2005
f
B,V
: Influence of concrete strength
Concrete strength
designation
(ENV 206)
Cylinder compressive
strength,
f
ck,cyl
[N/mm]
Cube compressive
strength,
f
ck,cube
[N/mm]
f
B,V
C20/25 20 25 1
C25/30 25 30 1.1
C30/37 30 37 1.22
C35/45 35 45 1.34
C40/50 40 50 1.41
C45/55 45 55 1.48
C50/60 50 60 1.55
Concrete cylinder:
Height 30cm,
Diameter 15cm
Concrete cube:
side length 15 cm
Concrete test specimen geometry
f
AR,V
: Influence of edge distance and spacing
c/c
min
f
AR,V
1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0
Single-anchor with
edge influence,
1.00 1.31 1.66 2.02 2.41 2.83 3.26 3.72 4.19 4.69 5.20 5.72 6.27 6.83 7.41 8.00
s/c
min
1.0 0.67 0.84 1.03 1.22 1.43 1.65 1.88 2.12 2.36 2.62 2.89 3.16 3.44 3.73 4.03 4.33
1.5 0.75 0.93 1.12 1.33 1.54 1.77 2.00 2.25 2.50 2.76 3.03 3.31 3.60 3.89 4.19 4.50
2.0 0.83 1.02 1.22 1.43 1.65 1.89 2.13 2.38 2.63 2.90 3.18 3.46 3.75 4.05 4.35 4.67
2.5 0.92 1.11 1.32 1.54 1.77 2.00 2.25 2.50 2.77 3.04 3.32 3.61 3.90 4.21 4.52 4.83
3.0 1.00 1.20 1.42 1.64 1.88 2.12 2.37 2.63 2.90 3.18 3.46 3.76 4.06 4.36 4.68 5.00
3.5 1.30 1.52 1.75 1.99 2.24 2.50 2.76 3.04 3.32 3.61 3.91 4.21 4.52 4.84 5.17
4.0 1.62 1.86 2.10 2.36 2.62 2.89 3.17 3.46 3.75 4.05 4.36 4.68 5.00 5.33
4.5 1.96 2.21 2.47 2.74 3.02 3.31 3.60 3.90 4.20 4.52 4.84 5.17 5.50
5.0 2.33 2.59 2.87 3.15 3.44 3.74 4.04 4.35 4.67 5.00 5.33 5.67
5.5 2.71 2.99 3.28 3.57 3.88 4.19 4.50 4.82 5.15 5.49 5.83
6.0 2.83 3.11 3.41 3.71 4.02 4.33 4.65 4.98 5.31 5.65 6.00
6.5 3.24 3.54 3.84 4.16 4.47 4.80 5.13 5.47 5.82 6.17
7.0 3.67 3.98 4.29 4.62 4.95 5.29 5.63 5.98 6.33
7.5 4.11 4.43 4.76 5.10 5.44 5.79 6.14 6.50
8.0 4.57 4.91 5.25 5.59 5.95 6.30 6.67
8.5 5.05 5.40 5.75 6.10 6.47 6.83
9.0 5.20 5.55 5.90 6.26 6.63 7.00
9.5 5.69 6.05 6.42 6.79 7.17
10.0 6.21 6.58 6.95 7.33
10.5 6.74 7.12 7.50
11.0 7.28 7.67
11.5 7.83
12.0 8.00
25
f
f
cube , ck
V , B

Limits:
25 N/mm
2
s f
ck,cube
s 60 N/mm
2
These results are for a
two-anchor fastening.
For fastenings with two or
more anchors, use the
general formulae for n
anchors.
HIT-RE 500 injection adhesive with rebar
Issue 2005 253
3
c
c
s
s
s
2,2
1
2
3
n-1
s
c
2,1
h >1,5 c
Note: It is assumed that only the row of anchors closest to
the free concrete edge carries the centric shear load.
f
AR,V
: Influence of edge distance and spacing
Formula for single-anchor fastening influenced
only by 1 edge
min min
V , AR
c
c
c
c
f
Formula for two-anchors fastening (edge plus
1 spacing) only valid for s < 3c
min min
V , AR
c
c
c 6
s c 3
f

General formula for n-anchor fastening (edge plus


n-1 spacing) only valid when s
1
and s
n-1
are each < 3c and c
2
> 1.5c
min min
1 n 2 1
V , AR
c
c
c n 3
s ... s s c 3
f

- - - -

-
f
,V
: Influence of loading direction
Angle, [] f
,V
0 to 55 1
60 1.1
70 1.2
80 1.5
90 to 180 2
V
Rd,s
: Steel design shear resistance
Rebar C [mm] 8 10 12 14 16 20 25 28 32 36 40
V
Rd,s
1)
[kN] 11.1 17.3 24.9 33.9 44.3 69.3 108.0 135.3 176.7 237.3 276.4
1)
The steel design shear resistance is calculated from V
Rd,s
= (0,6A
s
f
uk
)/
Ms,V
. The partial safety factor,
Ms,V
, for rebar sections, type BSt
500, is 1.5.
V
Rd
: System design shear resistance
V
Rd
= lower of V
Rd,c
and V
Rd,s
Combined loading: Only if tensile load and shear load applied (See page 31 and section 4 Examples).
1 f
V ,

sin 5 , 0 cos
1
f
V ,
-

2 f
V ,

for 0 s s 55
for 55 < s 90
for 90 < s 180
Formulae:
V ... applied shear force

results
tabulated
below


HSL-3 heavy duty anchor


52
Features:
- suitable for the tension zone
- high loading capacity
- force-controlled expansion
- reliable pull-down of part fastened
- no rotation in hole when tightening bolt
Bolt Material:

- grade 8.8 acc. DIN EN ISO 898-1
galvanised to min. 5 microns
Versions:
HSL-3 - bolt
HSL-3-G - nut
HSL-3-B - safety cap (automatic torque control)
HSL-3-SK - countersunk head
HSL-3-SH - socket head

















Basic loading data (for a single anchor): HSL-3 / HSL-3-B / HSL-3-SH*/ HSL-3-SK*

All data on this page applies to
concrete: as specified in the table
no edge distance and spacing influence
correct setting (See setting operations page 56)
steel failure

For detailed design method, see pages 57 61.






Mean ultimate resistance, R
u,m
[kN]: concrete C20/25

Anchor size M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20 M24
Tensile N
Ru,m

28.4 37.7 53.4 71.3 100.6 133.1 20.3 26.9 38.1 50.9 71.8 95.0
Shear V
Ru,m

43.0 63.5 88.9 128.6 160.6 239.7 43.0 63.5 88.9 128.6 160.6 239.7

Characteristic resistance, R
k
[kN]: concrete C20/25

Anchor size M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20 M24
Tensile N
Rk

23.4 29.5 36.1 50.4 70.4 92.6 16.7 21.1 25.8 36.0 50.3 66.1
Shear V
Rk

31.1 49.2 71.7 101.1 141.9 177.4 31.1 49.2 71.7 101.1 141.9 177.4



* HSL-3-SH, HSL-3-SK is only available up to M12
HSL-3
HSL-3-G
HSL-3-B
HSL-3-SK
HSL-3-SH



Concrete
Tensile
zone
Fire
resistance
Hilti Anchor
Programme
Close edge
distance/
spacing


Fatigue Shock
cracked concrete
non-cracked concrete

HSL-3 heavy duty anchor


53


Following values according to the:

Concrete Capacity Method

Design resistance, R
d
[kN]: concrete f
ck,cube
=25 N/mm
2


Anchor size M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20 M24
Tensile N
Rd

15.6 19.7 24.1 33.6 46.9 61.7 6.7 10.7 17.2 24.0 33.5 44.1
Shear V
Rd

24.9 39.4 57.4 80.9 113.5 141.9 24.9 39.4 57.4 80.9 113.5 141.9

Recommended load, L
rec
[kN]: concrete f
ck,cube
=25 N/mm
2


Anchor size M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20 M24
Tensile N
Rec

11.1 14.0 17.2 24.0 33.5 44.1 4.8 7.6 12.3 17.1 24.0 31.5
Shear V
Rec

17.8 28.1 41.0 57.8 81.1 101.4 17.8 28.1 41.0 57.8 81.1 101.4


Basic loading data (for a single anchor): HSL-3 G

All data on this section applies to
concrete: as specified in the table
no edge distance and spacing influence
correct setting (See setting operations page 56)
steel failure
For detailed design method, see pages 56 60.





Characteristic resistance, R
k
[kN]: concrete C20/25

Anchor size M8 M10 M12 M16 M20 M8 M10 M12 M16 M20
Tensile N
Rk

23.4 29.5 36.1 50.4 70.4 16.7 21.1 25.8 36.0 50.3
Shear V
Rk

26.1 34.8 54.3 85.7 141.9 26.1 34.8 54.3 85.7 141.9

Following values according the:

Concrete Capacity Method

Design resistance, R
d
[kN]: concrete f
ck,cube
=25 N/mm
2


Anchor size M8 M10 M12 M16 M20 M8 M10 M12 M16 M20
Tensile N
Rd

15.6 19.7 24.1 33.6 46.9 6.7 10.7 17.2 24.0 33.5
Shear V
Rd

20.9 27.8 43.4 68.6 113.5 20.9 27.8 43.4 68.6 113.5

Recommended load L
rec
[kN]: f
ck,cube
=25 N/mm
2


Anchor size M8 M10 M12 M16 M20 M8 M10 M12 M16 M20
Tensile N
Rec

11.1 14.0 17.2 24.0 33.5 4.8 7.6 12.3 17.1 24.0
Shear V
Rec

14.9 19.9 31.0 49.0 81.1 14.9 19.9 31.0 49.0 81.1


Installation equipment

Rotary hammer (TE1, TE2, TE5, TE6, TE6A, TE15, TE15-C, TE18-M, TE35, TE55, TE76), hammer, torque
wrench, blow out pump.
cracked concrete
non-cracked concrete

HSL-3 heavy duty anchor
56

Setting details
HSL-3

Anchor size M8/ t
fix
M10/ t
fix
M12/ t
fix
M16/ t
fix
M20/ t
fix
M24/ t
fix

t
fix
[mm]
Fastenable thickness (small/medium/large)
1)
5/20/40 5/20/40 5/25/50 10/25/50 10/30/60 10/30/60
d
0
[mm] Nominal diameter of drill hole 12 15 18 24 28 32
[mm] Diameter of drill bit 12.5 15.5 18.5 24.55 28.55 32.7
h
1
[mm] Depth of drill hole 80 90 105 125 155 180
h
ef
[mm] Effective anchorage depth 60 70 80 100 125 150
l [mm] Anchor length
2)

t
fix
small
t
fix
medium
t
fix
large

83
98
118

95
110
130

111
131
156

138
153
178

163
183
213

185
205
235
[mm] Head height and washer 7.5 10 11 14 17 19
d
w
[mm] Washer diameter 20 25 30 40 45 50
h
min
[mm] Min. base material thickness 120 140 160 200 250 300
d
f
[mm] Clearance hole 14 17 20 26 31 35
S
W
[mm] Width across 13 17 19 24 30 36
T
inst
[Nm] Torque moment 25 50 80 120 200 250

HSL-3-SH

Anchor size
M8/ t
fix
M10/ t
fix
M12/ t
fix

t
fix
[mm]
Fastenable thickness
1)
5 20 25
d
0
[mm] Nominal diameter of drill hole 12 15 18
[mm] Diameter of drill bit 12,5 15,5 18,5
h
1
[mm] Depth of drill hole 85 95 110
h
ef
[mm] Effective anchorage depth 60 70 80
l [mm] Anchor length
2)
88 120 142
[mm] Head height and washer 10 13 15
d
w
[mm] Washer diameter 20 25 30
h
min
[mm] Min. base material thickness 120 140 160
d
f
[mm] Clearance hole 14 17 20
S
W
[mm] Width across 6 8 10
T
inst
[Nm] Torque moment 20 35 60

HSL-3-SK

Anchor size
M8/ t
fix
M10/ t
fix
M12/ t
fix

t
fix
[mm]
Fastenable thickness (small/ /large)
1)
10/20 20 25
d
0
[mm] Nominal diameter of drill hole 12 15 18
[mm] Diameter of drill bit 12,5 15,5 18,5
h
1
[mm] Depth of drill hole 80 90 105
h
ef
[mm] Effective anchorage depth 60 70 80
l [mm] Anchor length
2)
80/90 100 120
h
min
[mm] Min. base material thickness 120 140 160
d
f
[mm] Clearance hole 14 17 20
S
W
[mm] Size of hexagon socket screw key 6 8 10
T
inst
[Nm] Torque moment 25 50 80


1)
Other t
fix
possible
2)
Other anchor length possible
according to other t
fix


1)
Other t
fix
possible
2)
Other anchor length possible
according to other t
fix



HSL-3 heavy duty anchor
56

HSL-3-G

Anchor size
M8/ t
fix
M10/ t
fix
M12/ t
fix
M16/ t
fix

M20/ t
fix

t
fix
[mm] Fastenable thickness

(small/medium/large/ 100 mm)
1)
5/20/40/
100
5/20/40/
100
5/25/50/
100
10/25/50/
100
10/30/60/1
00
d
0
[mm] Nominal diameter of drill hole 12 15 18 24 28
[mm] Diameter of drill bit 12,5 15,5 18,5 24,55 28,55
h
1
[mm] Depth of drill hole 80 90 105 125 155
h
ef
[mm] Effective anchorage depth 60 70 80 100 125
l [mm] Anchor length
2)

t
fix
small
t
fix
medium
t
fix
large
t
fix
=100 mm

87
102
122
182

100
115
135
195

119
139
164
214

148
163
188
238

170
190
220
260
[mm] Head height and washer 8 11 13 17 20
d
w
[mm] Washer diameter 20 25 30 40 45
h
min
[mm] Min. base material thickness 120 140 160 200 250
d
f
[mm] Clearance hole (through setting) 14 17 20 26 31
d
f
[mm] Clearance hole (only threaded rod carries the load) 9 12 14 18 22
S
W
[mm] Width across 13 17 19 24 30
T
inst
[Nm] Torque moment 20 35 60 80 160


































1)
Other t
fix
possible
2)
Other anchor length possible
according to other t
fix



HSL-3 heavy duty anchor
56
HSL-3-B

Anchor size
M12/ t
fix
M16/ t
fix
M20/ t
fix
M24/ t
fix

t
fix
[mm] ( small / medium / large)
1)
5/25/50 10/25/50 10/30/60 10/30/60
d
0
[mm] Nominal diameter of drill hole 18 24 28 32
[mm] Diameter of drill bit 18.5 24.55 28.55 32.7
h
1
[mm] Depth of drill hole 105 125 155 180
h
ef
[mm] Effective anchorage depth 80 100 125 150
l [mm] Anchor length
2)

t
fix
small
t
fix
medium
t
fix
large

117
137
162

144
159
184

169
189
219

191
211
241
[mm] Head height and washer 16.5 19.5 22.5 24.5
d
w
[mm] Washer diameter 30 40 45 50
h
min
[mm] Min. base material thickness 160 200 250 300
d
f
[mm] Clearance hole 20 26 31 35
S
W
[mm] Width across 24 30 36 41
T
inst
[Nm] Torque moment - - - -









































1)
Other t
fix
possible
2)
Other anchor length possible
according to other t
fix


h
min

h
1

h
ef

T
inst.
t
fix



HSL-3 heavy duty anchor
57

Setting operations

1

2

3

4

Drill hole. Blow out dust and fragments. Install anchor. Apply tightening torque
(for HSL-3-B: no torque wrench is
needed)


Anchor mechanical properties

Anchor size M8 M10 M12 M16 M20 M24
f
uk
[N/mm
2
] Nominal tensile strength 800 800 800 800 830 830
f
yk
[N/mm
2
] Yield strength 8.8 640 640 640 640 640 640
A
s
[mm
2
] Stressed crossed-section 36.6 58.0 84.3 157.0 245.0 353.0
W [mm
2
] Elastic moment of resistance 30 60 105 266 519 898
M
rec
[Nm] Recommended bending moment without sleeve 12.5 24.9 43.7 111.0 216.4 374.2




Detailed design method - Hilti CC




TENSION

The tensile design resistance of a single anchor
is the lower of,
N
Rd,p
: concrete pull-out resistance
N
Rd,c
: concrete cone resistance
N
Rd,s
: steel resistance

N
Rd,p
: Pull-out resistance
Pull-out failure mode is only determinating for the anchor sizes M8 and M10 in
cracked concrete
B
o
p , Rd p , Rd
f N N =

Concrete compressive strength. f
ck.cube(150)
=25 N/mm
2

Anchor size M8
M10
N
0
Rd,p
1)
[kN] cracked concrete 6.7 10.7
1)
The tensile design resistance is calculated from the tensile characteristic resistance N
o
Rk,p
by N
o
Rd,p
=N
o
Rk,p
/
Mp
, where the partial
safety factor
Mp
is equal to 1.8 for M8 and 1.5 for M10.


N
c
s
h
rec,c/s

(The Hilti CC-Method is a simplified Version of ETAG Annex C)

HSL-3 heavy duty anchor
60

N
Rd,c
: Concrete cone resistance











N
0
Rd,c
: Design concrete cone resistance
Concrete compressive strength. f
ck.cube(150)
=25 N/mm
2

Anchor size
M8 M10 M12 M16 M20 M24
N
0
Rd,c
1)
[kN] non-cracked concrete
15.6 19.7 24.1 33.6 46.9 61.7
N
0
Rd,c
1)
[kN] cracked concrete
11.1 14.1 17.2 24.0 33.5 44.1
ef
h [mm] effective embedment depth
60 70 80 100 125 150
1)
The tensile design resistance is calculated from the tensile characteristic resistance N
o
Rk,c
by N
o
Rd,c
=N
o
Rk,c
/
Mc,N
, where the partial
safety factor
Mc,N
is equal to 1.5.

f
B
: Influence of concrete strength
Concrete strength
designation
(ENV 206)
Cylinder compressive
strength
f
ck,cyl
[N/mm]
Cube compressive
strength
f
ck,cube
[N/mm]

f
B

C20/25 20 25 1.0
C25/30 25 30 1.1
C30/37 30 37 1.22
C35/45 35 45 1.34
C40/50 40 50 1.41
C45/55 45 55 1.48
C50/60 50 60 1.55

Concrete cylinder:
height 30cm, 15cm
diameter
Concrete cube:
side length 15cm

Concrete test specimen geometry

f
AN
: Influence of anchor spacing
Anchor
spacing
Anchor size
s [mm]
M8 M10 M12 M16 M20 M24
60 0.67
70 0.69 0.67
80 0.72 0.69 0.67
90 0.75 0.71 0.69
100 0.78 0.74 0.71 0.67
110 0.81 0.76 0.73 0.68
120 0.83 0.79 0.75 0.70
130 0.86 0.81 0.77 0.72 0.67
140 0.89 0.83 0.79 0.73 0.69
150 0.92 0.86 0.81 0.75 0.70 0.67
175 0.99 0.92 0.86 0.79 0.73 0.69
200 0.98 0.92 0.83 0.77 0.72
225 0.97 0.88 0.80 0.75
250 0.92 0.83 0.78
275 0.96 0.87 0.81
300 1.00 0.90 0.83
325 0.93 0.86
350 0.97 0.89
375 1.00 0.92
400 0.94
425 0.97
450 1.00
ef
AN
h 6
s
5 . 0 f

+ =

Limits:
N , cr min
s s s
ef
h
N cr,
s 3 =

N , R N , A B
o
c , Rd c , Rd
f f f N N =
25
cube ck,
f
B
f =


Limits:
25 N/mm
2
f
ck,cube(150)
60 N/mm
2



HSL-3 heavy duty anchor
60



ef
RN
h
c
5 . 0 25 . 0 f + =

Limits:
c
min
c c
cr,N

c
cr,N
=1.5h
ef



f
RN
: Influence of edge distance

















Minimum thickness of concrete member, minimum spacing and minimum edge distance of anchors in cracked
and uncracked concrete

Anchor size M8 M10 M12 M16 M20 M24
s
min
[mm] 60 70 80 100 125 150
Minimum spacing
for c [mm] 100 100 160 240 300 300
c
min
[mm] 60 70 80 100 150 150
Minimum edge distance
for s [mm] 100 160 240 240 300 300
Minimum thickness h
min
[mm] 120 140 160 200 250 300

Intermediate values by linear interpolation.

N
Rd,s
: Steel design tensile resistance
Anchor size
M8 M10 M12 M16 M20 M24
N
Rd,s
1)
[kN]
19.5 30.9 44.9 83.7 130.7 188.3
1)
The tensile design resistance is calculated from the tensile characteristic resistance N
Rd,s
by N
Rd,s
=N
Rk,s
/
Ms
, where the partial
safety factor
Ms
is 1.5.

N
Rd
: System design tensile resistance

N
Rd
= lower of N
Rd,p
, N
Rd,c
and N
Rd,s


Combined loading: Only if tensile load and shear load applied (See page 32 and section 4 Examples).

Detailed design method - Hilti CC




SHEAR

The design shear resistance of a single anchor
is the lower of,
V
Rd,c
: concrete edge resistance
V
Rd,s
: steel resistance
Edge distance Anchor size
c [mm]
M8 M10 M12 M16 M20 M24
60 0.75
70 0.83 0.75
80 0.92 0.82 0.75
90 1.00 0.89 0.81
100 0.96 0.88 0.75
105 1.00 0.91 0.78
120 1.00 0.85
140 0.95
150 1.00 0.85 0.75
175 0.95 0.83
200 0.92
225 1.00
V
c
s
rec,c/s
c

>
1
.
5
c
2
c

>
1
.
5
c
2
h
>
1
.
5
c
(The Hilti CC-Method is a simplified Version of ETAG Annex C)
Note: If the conditions for
h and c
2
are not met, consult your
Hilti technical advisory service.
Note: If more than 3 edges
are smaller than c
cr,N

consult your Hilti
Technical Advisory
Service


HSL-3 heavy duty anchor


52
Features:
- suitable for the tension zone
- high loading capacity
- force-controlled expansion
- reliable pull-down of part fastened
- no rotation in hole when tightening bolt
Bolt Material:

- grade 8.8 acc. DIN EN ISO 898-1
galvanised to min. 5 microns
Versions:
HSL-3 - bolt
HSL-3-G - nut
HSL-3-B - safety cap (automatic torque control)
HSL-3-SK - countersunk head
HSL-3-SH - socket head

















Basic loading data (for a single anchor): HSL-3 / HSL-3-B / HSL-3-SH*/ HSL-3-SK*

All data on this page applies to
concrete: as specified in the table
no edge distance and spacing influence
correct setting (See setting operations page 56)
steel failure

For detailed design method, see pages 57 61.






Mean ultimate resistance, R
u,m
[kN]: concrete C20/25

Anchor size M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20 M24
Tensile N
Ru,m

28.4 37.7 53.4 71.3 100.6 133.1 20.3 26.9 38.1 50.9 71.8 95.0
Shear V
Ru,m

43.0 63.5 88.9 128.6 160.6 239.7 43.0 63.5 88.9 128.6 160.6 239.7

Characteristic resistance, R
k
[kN]: concrete C20/25

Anchor size M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20 M24
Tensile N
Rk

23.4 29.5 36.1 50.4 70.4 92.6 16.7 21.1 25.8 36.0 50.3 66.1
Shear V
Rk

31.1 49.2 71.7 101.1 141.9 177.4 31.1 49.2 71.7 101.1 141.9 177.4



* HSL-3-SH, HSL-3-SK is only available up to M12
HSL-3
HSL-3-G
HSL-3-B
HSL-3-SK
HSL-3-SH



Concrete
Tensile
zone
Fire
resistance
Hilti Anchor
Programme
Close edge
distance/
spacing


Fatigue Shock
cracked concrete
non-cracked concrete

HSL-3 heavy duty anchor


53


Following values according to the:

Concrete Capacity Method

Design resistance, R
d
[kN]: concrete f
ck,cube
=25 N/mm
2


Anchor size M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20 M24
Tensile N
Rd

15.6 19.7 24.1 33.6 46.9 61.7 6.7 10.7 17.2 24.0 33.5 44.1
Shear V
Rd

24.9 39.4 57.4 80.9 113.5 141.9 24.9 39.4 57.4 80.9 113.5 141.9

Recommended load, L
rec
[kN]: concrete f
ck,cube
=25 N/mm
2


Anchor size M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20 M24
Tensile N
Rec

11.1 14.0 17.2 24.0 33.5 44.1 4.8 7.6 12.3 17.1 24.0 31.5
Shear V
Rec

17.8 28.1 41.0 57.8 81.1 101.4 17.8 28.1 41.0 57.8 81.1 101.4


Basic loading data (for a single anchor): HSL-3 G

All data on this section applies to
concrete: as specified in the table
no edge distance and spacing influence
correct setting (See setting operations page 56)
steel failure
For detailed design method, see pages 56 60.





Characteristic resistance, R
k
[kN]: concrete C20/25

Anchor size M8 M10 M12 M16 M20 M8 M10 M12 M16 M20
Tensile N
Rk

23.4 29.5 36.1 50.4 70.4 16.7 21.1 25.8 36.0 50.3
Shear V
Rk

26.1 34.8 54.3 85.7 141.9 26.1 34.8 54.3 85.7 141.9

Following values according the:

Concrete Capacity Method

Design resistance, R
d
[kN]: concrete f
ck,cube
=25 N/mm
2


Anchor size M8 M10 M12 M16 M20 M8 M10 M12 M16 M20
Tensile N
Rd

15.6 19.7 24.1 33.6 46.9 6.7 10.7 17.2 24.0 33.5
Shear V
Rd

20.9 27.8 43.4 68.6 113.5 20.9 27.8 43.4 68.6 113.5

Recommended load L
rec
[kN]: f
ck,cube
=25 N/mm
2


Anchor size M8 M10 M12 M16 M20 M8 M10 M12 M16 M20
Tensile N
Rec

11.1 14.0 17.2 24.0 33.5 4.8 7.6 12.3 17.1 24.0
Shear V
Rec

14.9 19.9 31.0 49.0 81.1 14.9 19.9 31.0 49.0 81.1


Installation equipment

Rotary hammer (TE1, TE2, TE5, TE6, TE6A, TE15, TE15-C, TE18-M, TE35, TE55, TE76), hammer, torque
wrench, blow out pump.
cracked concrete
non-cracked concrete

HSL-3 heavy duty anchor
56

Setting details
HSL-3

Anchor size M8/ t
fix
M10/ t
fix
M12/ t
fix
M16/ t
fix
M20/ t
fix
M24/ t
fix

t
fix
[mm]
Fastenable thickness (small/medium/large)
1)
5/20/40 5/20/40 5/25/50 10/25/50 10/30/60 10/30/60
d
0
[mm] Nominal diameter of drill hole 12 15 18 24 28 32
[mm] Diameter of drill bit 12.5 15.5 18.5 24.55 28.55 32.7
h
1
[mm] Depth of drill hole 80 90 105 125 155 180
h
ef
[mm] Effective anchorage depth 60 70 80 100 125 150
l [mm] Anchor length
2)

t
fix
small
t
fix
medium
t
fix
large

83
98
118

95
110
130

111
131
156

138
153
178

163
183
213

185
205
235
[mm] Head height and washer 7.5 10 11 14 17 19
d
w
[mm] Washer diameter 20 25 30 40 45 50
h
min
[mm] Min. base material thickness 120 140 160 200 250 300
d
f
[mm] Clearance hole 14 17 20 26 31 35
S
W
[mm] Width across 13 17 19 24 30 36
T
inst
[Nm] Torque moment 25 50 80 120 200 250

HSL-3-SH

Anchor size
M8/ t
fix
M10/ t
fix
M12/ t
fix

t
fix
[mm]
Fastenable thickness
1)
5 20 25
d
0
[mm] Nominal diameter of drill hole 12 15 18
[mm] Diameter of drill bit 12,5 15,5 18,5
h
1
[mm] Depth of drill hole 85 95 110
h
ef
[mm] Effective anchorage depth 60 70 80
l [mm] Anchor length
2)
88 120 142
[mm] Head height and washer 10 13 15
d
w
[mm] Washer diameter 20 25 30
h
min
[mm] Min. base material thickness 120 140 160
d
f
[mm] Clearance hole 14 17 20
S
W
[mm] Width across 6 8 10
T
inst
[Nm] Torque moment 20 35 60

HSL-3-SK

Anchor size
M8/ t
fix
M10/ t
fix
M12/ t
fix

t
fix
[mm]
Fastenable thickness (small/ /large)
1)
10/20 20 25
d
0
[mm] Nominal diameter of drill hole 12 15 18
[mm] Diameter of drill bit 12,5 15,5 18,5
h
1
[mm] Depth of drill hole 80 90 105
h
ef
[mm] Effective anchorage depth 60 70 80
l [mm] Anchor length
2)
80/90 100 120
h
min
[mm] Min. base material thickness 120 140 160
d
f
[mm] Clearance hole 14 17 20
S
W
[mm] Size of hexagon socket screw key 6 8 10
T
inst
[Nm] Torque moment 25 50 80


1)
Other t
fix
possible
2)
Other anchor length possible
according to other t
fix


1)
Other t
fix
possible
2)
Other anchor length possible
according to other t
fix



HSL-3 heavy duty anchor
56

HSL-3-G

Anchor size
M8/ t
fix
M10/ t
fix
M12/ t
fix
M16/ t
fix

M20/ t
fix

t
fix
[mm] Fastenable thickness

(small/medium/large/ 100 mm)
1)
5/20/40/
100
5/20/40/
100
5/25/50/
100
10/25/50/
100
10/30/60/1
00
d
0
[mm] Nominal diameter of drill hole 12 15 18 24 28
[mm] Diameter of drill bit 12,5 15,5 18,5 24,55 28,55
h
1
[mm] Depth of drill hole 80 90 105 125 155
h
ef
[mm] Effective anchorage depth 60 70 80 100 125
l [mm] Anchor length
2)

t
fix
small
t
fix
medium
t
fix
large
t
fix
=100 mm

87
102
122
182

100
115
135
195

119
139
164
214

148
163
188
238

170
190
220
260
[mm] Head height and washer 8 11 13 17 20
d
w
[mm] Washer diameter 20 25 30 40 45
h
min
[mm] Min. base material thickness 120 140 160 200 250
d
f
[mm] Clearance hole (through setting) 14 17 20 26 31
d
f
[mm] Clearance hole (only threaded rod carries the load) 9 12 14 18 22
S
W
[mm] Width across 13 17 19 24 30
T
inst
[Nm] Torque moment 20 35 60 80 160


































1)
Other t
fix
possible
2)
Other anchor length possible
according to other t
fix



HSL-3 heavy duty anchor
56
HSL-3-B

Anchor size
M12/ t
fix
M16/ t
fix
M20/ t
fix
M24/ t
fix

t
fix
[mm] ( small / medium / large)
1)
5/25/50 10/25/50 10/30/60 10/30/60
d
0
[mm] Nominal diameter of drill hole 18 24 28 32
[mm] Diameter of drill bit 18.5 24.55 28.55 32.7
h
1
[mm] Depth of drill hole 105 125 155 180
h
ef
[mm] Effective anchorage depth 80 100 125 150
l [mm] Anchor length
2)

t
fix
small
t
fix
medium
t
fix
large

117
137
162

144
159
184

169
189
219

191
211
241
[mm] Head height and washer 16.5 19.5 22.5 24.5
d
w
[mm] Washer diameter 30 40 45 50
h
min
[mm] Min. base material thickness 160 200 250 300
d
f
[mm] Clearance hole 20 26 31 35
S
W
[mm] Width across 24 30 36 41
T
inst
[Nm] Torque moment - - - -









































1)
Other t
fix
possible
2)
Other anchor length possible
according to other t
fix


h
min

h
1

h
ef

T
inst.
t
fix



HSL-3 heavy duty anchor
57

Setting operations

1

2

3

4

Drill hole. Blow out dust and fragments. Install anchor. Apply tightening torque
(for HSL-3-B: no torque wrench is
needed)


Anchor mechanical properties

Anchor size M8 M10 M12 M16 M20 M24
f
uk
[N/mm
2
] Nominal tensile strength 800 800 800 800 830 830
f
yk
[N/mm
2
] Yield strength 8.8 640 640 640 640 640 640
A
s
[mm
2
] Stressed crossed-section 36.6 58.0 84.3 157.0 245.0 353.0
W [mm
2
] Elastic moment of resistance 30 60 105 266 519 898
M
rec
[Nm] Recommended bending moment without sleeve 12.5 24.9 43.7 111.0 216.4 374.2




Detailed design method - Hilti CC




TENSION

The tensile design resistance of a single anchor
is the lower of,
N
Rd,p
: concrete pull-out resistance
N
Rd,c
: concrete cone resistance
N
Rd,s
: steel resistance

N
Rd,p
: Pull-out resistance
Pull-out failure mode is only determinating for the anchor sizes M8 and M10 in
cracked concrete
B
o
p , Rd p , Rd
f N N =

Concrete compressive strength. f
ck.cube(150)
=25 N/mm
2

Anchor size M8
M10
N
0
Rd,p
1)
[kN] cracked concrete 6.7 10.7
1)
The tensile design resistance is calculated from the tensile characteristic resistance N
o
Rk,p
by N
o
Rd,p
=N
o
Rk,p
/
Mp
, where the partial
safety factor
Mp
is equal to 1.8 for M8 and 1.5 for M10.


N
c
s
h
rec,c/s

(The Hilti CC-Method is a simplified Version of ETAG Annex C)

HSL-3 heavy duty anchor
60

N
Rd,c
: Concrete cone resistance











N
0
Rd,c
: Design concrete cone resistance
Concrete compressive strength. f
ck.cube(150)
=25 N/mm
2

Anchor size
M8 M10 M12 M16 M20 M24
N
0
Rd,c
1)
[kN] non-cracked concrete
15.6 19.7 24.1 33.6 46.9 61.7
N
0
Rd,c
1)
[kN] cracked concrete
11.1 14.1 17.2 24.0 33.5 44.1
ef
h [mm] effective embedment depth
60 70 80 100 125 150
1)
The tensile design resistance is calculated from the tensile characteristic resistance N
o
Rk,c
by N
o
Rd,c
=N
o
Rk,c
/
Mc,N
, where the partial
safety factor
Mc,N
is equal to 1.5.

f
B
: Influence of concrete strength
Concrete strength
designation
(ENV 206)
Cylinder compressive
strength
f
ck,cyl
[N/mm]
Cube compressive
strength
f
ck,cube
[N/mm]

f
B

C20/25 20 25 1.0
C25/30 25 30 1.1
C30/37 30 37 1.22
C35/45 35 45 1.34
C40/50 40 50 1.41
C45/55 45 55 1.48
C50/60 50 60 1.55

Concrete cylinder:
height 30cm, 15cm
diameter
Concrete cube:
side length 15cm

Concrete test specimen geometry

f
AN
: Influence of anchor spacing
Anchor
spacing
Anchor size
s [mm]
M8 M10 M12 M16 M20 M24
60 0.67
70 0.69 0.67
80 0.72 0.69 0.67
90 0.75 0.71 0.69
100 0.78 0.74 0.71 0.67
110 0.81 0.76 0.73 0.68
120 0.83 0.79 0.75 0.70
130 0.86 0.81 0.77 0.72 0.67
140 0.89 0.83 0.79 0.73 0.69
150 0.92 0.86 0.81 0.75 0.70 0.67
175 0.99 0.92 0.86 0.79 0.73 0.69
200 0.98 0.92 0.83 0.77 0.72
225 0.97 0.88 0.80 0.75
250 0.92 0.83 0.78
275 0.96 0.87 0.81
300 1.00 0.90 0.83
325 0.93 0.86
350 0.97 0.89
375 1.00 0.92
400 0.94
425 0.97
450 1.00
ef
AN
h 6
s
5 . 0 f

+ =

Limits:
N , cr min
s s s
ef
h
N cr,
s 3 =

N , R N , A B
o
c , Rd c , Rd
f f f N N =
25
cube ck,
f
B
f =


Limits:
25 N/mm
2
f
ck,cube(150)
60 N/mm
2



HSL-3 heavy duty anchor
60



ef
RN
h
c
5 . 0 25 . 0 f + =

Limits:
c
min
c c
cr,N

c
cr,N
=1.5h
ef



f
RN
: Influence of edge distance

















Minimum thickness of concrete member, minimum spacing and minimum edge distance of anchors in cracked
and uncracked concrete

Anchor size M8 M10 M12 M16 M20 M24
s
min
[mm] 60 70 80 100 125 150
Minimum spacing
for c [mm] 100 100 160 240 300 300
c
min
[mm] 60 70 80 100 150 150
Minimum edge distance
for s [mm] 100 160 240 240 300 300
Minimum thickness h
min
[mm] 120 140 160 200 250 300

Intermediate values by linear interpolation.

N
Rd,s
: Steel design tensile resistance
Anchor size
M8 M10 M12 M16 M20 M24
N
Rd,s
1)
[kN]
19.5 30.9 44.9 83.7 130.7 188.3
1)
The tensile design resistance is calculated from the tensile characteristic resistance N
Rd,s
by N
Rd,s
=N
Rk,s
/
Ms
, where the partial
safety factor
Ms
is 1.5.

N
Rd
: System design tensile resistance

N
Rd
= lower of N
Rd,p
, N
Rd,c
and N
Rd,s


Combined loading: Only if tensile load and shear load applied (See page 32 and section 4 Examples).

Detailed design method - Hilti CC




SHEAR

The design shear resistance of a single anchor
is the lower of,
V
Rd,c
: concrete edge resistance
V
Rd,s
: steel resistance
Edge distance Anchor size
c [mm]
M8 M10 M12 M16 M20 M24
60 0.75
70 0.83 0.75
80 0.92 0.82 0.75
90 1.00 0.89 0.81
100 0.96 0.88 0.75
105 1.00 0.91 0.78
120 1.00 0.85
140 0.95
150 1.00 0.85 0.75
175 0.95 0.83
200 0.92
225 1.00
V
c
s
rec,c/s
c

>
1
.
5
c
2
c

>
1
.
5
c
2
h
>
1
.
5
c
(The Hilti CC-Method is a simplified Version of ETAG Annex C)
Note: If the conditions for
h and c
2
are not met, consult your
Hilti technical advisory service.
Note: If more than 3 edges
are smaller than c
cr,N

consult your Hilti
Technical Advisory
Service

HSL-3 heavy duty anchor
60

V
Rd,c
: Concrete edge design resistance
The lowest concrete edge resistance must be calculated. All nearby edges must be checked, (not only the
edge in the direction of shear). Shear direction is accounted for by the factor f
,V
.

V , AR V , B
o
c , Rd c , Rd
f f f V V =



V
0
Rd,c
: Concrete edge design resistance
Concrete compressive strength f
ck,cube(150)
=25 N/mm
2

at a minimum edge distance
min
c
Anchor size
M8 M10 M12 M16 M20 M24
V
0
Rd,c
[kN] non-cracked concrete
4.7 6.5 8.6 13.7 27.5 29.7
V
0
Rd,c
[kN] cracked concrete
3.3 4.6 6.1 9.8 19.7 21.2
c
min
[mm] min. edge distance 60 70 80 100 150 150
s
min
[mm] min. spacing distance 100 160 240 240 300 300
1)
The shear design resistance is calculated from the shear characteristic resistance V
o
Rk,c
by V
o
Rd,c
=V
o
Rk,c
/
Mc,V
, where the partial
safety factor
Mc,V
is equal to 1.5.

f
B
: Influence of concrete strength
Concrete strength
designation
(ENV 206)
Cylinder compressive
strength
f
ck,cyl
[N/mm]
Cube compressive
strength
f
ck,cube
[N/mm]

f
B

C20/25 20 25 1.0
C25/30 25 30 1.1
C30/37 30 37 1.22
C35/45 35 45 1.34
C40/50 40 50 1.41
C45/55 45 55 1.48
C50/60 50 60 1.55

25
f
f
cube , ck
B
=

Limits:
25 N/mm
2
f
ck,cube(150)
60 N/mm
2



Concrete cylinder:
height 30cm, 15cm
diameter
Concrete cube:
side length 15cm

Concrete test specimen geometry


f
,V
: Influence of shear load direction
Angle []
f
,V

0 to 55 1
60 1.1
70 1.2
80 1.5
90 to 180 2

Formulae:
1 f
V ,
=

+
=

sin 5 . 0 cos
1
f
V ,
2 f
V ,
=


for 0 55
for 55 < 90
for 90 < 180


f
AR.V
: Influence of spacing and edge
distance

Formula for single anchor fastening
influenced only by edge
min min
V , AR
c
c
c
c
f =


Formula for two-anchor fastening valid for s <3c
min min
V , AR
c
c
c 6
s c 3
f
+
=

c
c
s
s
s
2,2
1
2
3
n-1
s
c
2,1
h >1,5 c
V ... applied shear force


results
tabulated
below
HSL-3 heavy duty anchor
61


General formula for n anchors (edge distance plus n-1 spacing)
only valid where s
1
to s
n-1
are all <3c and c
2
>1.5c
min min
1 n 2 1
V , AR
c
c
nc 3
s ... s s c 3
f
+ + + +
=



Note : It is assumed that only the row of anchors closest to the free concrete edge carries the centric shear load

c/c
min

f
AR.V

1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0
Single anchor with
edge influence
1.00 1.31 1.66 2.02 2.41 2.83 3.26 3.72 4.19 4.69 5.20 5.72 6.27 6.83 7.41 8.00
s/c
min
1.0 0.67 0.84 1.03 1.22 1.43 1.65 1.88 2.12 2.36 2.62 2.89 3.16 3.44 3.73 4.03 4.33
1.5 0.75 0.93 1.12 1.33 1.54 1.77 2.00 2.25 2.50 2.76 3.03 3.31 3.60 3.89 4.19 4.50
2.0 0.83 1.02 1.22 1.43 1.65 1.89 2.13 2.38 2.63 2.90 3.18 3.46 3.75 4.05 4.35 4.67
2.5 0.92 1.11 1.32 1.54 1.77 2.00 2.25 2.50 2.77 3.04 3.32 3.61 3.90 4.21 4.52 4.83
3.0 1.00 1.20 1.42 1.64 1.88 2.12 2.37 2.63 2.90 3.18 3.46 3.76 4.06 4.36 4.68 5.00
3.5 1.30 1.52 1.75 1.99 2.24 2.50 2.76 3.04 3.32 3.61 3.91 4.21 4.52 4.84 5.17
4.0 1.62 1.86 2.10 2.36 2.62 2.89 3.17 3.46 3.75 4.05 4.36 4.68 5.00 5.33
4.5 1.96 2.21 2.47 2.74 3.02 3.31 3.60 3.90 4.20 4.52 4.84 5.17 5.50
5.0 2.33 2.59 2.87 3.15 3.44 3.74 4.04 4.35 4.67 5.00 5.33 5.67
5.5 2.71 2.99 3.28 3.57 3.88 4.19 4.50 4.82 5.15 5.49 5.83
6.0 2.83 3.11 3.41 3.71 4.02 4.33 4.65 4.98 5.31 5.65 6.00
6.5 3.24 3.54 3.84 4.16 4.47 4.80 5.13 5.47 5.82 6.17
7.0 3.67 3.98 4.29 4.62 4.95 5.29 5.63 5.98 6.33
7.5 4.11 4.43 4.76 5.10 5.44 5.79 6.14 6.50
8.0 4.57 4.91 5.25 5.59 5.95 6.30 6.67
8.5 5.05 5.40 5.75 6.10 6.47 6.83
9.0 5.20 5.55 5.90 6.26 6.63 7.00
9.5 5.69 6.05 6.42 6.79 7.17
10.0 6.21 6.58 6.95 7.33
10.5 6.74 7.12 7.50
11.0 7.28 7.67
11.5 7.83


12.0 8.00




V
Rd,s
: Steel design shear resistance

Anchor size
M8 M10 M12 M16 M20 M24
HSL-3 24.9 39.4 57.4 80.9 113.5 141.9
HSL-3-SH, HSL-3-SK 24.9 39.4 57.4
- - -
HSL-3-G 20.9 27.8 43.4 68.6 113.5
-
V
Rd,s
[kN]
HSL-3-G threaded rod only 11.7 18.6 27.0 50.2 78.4
-

The shear design resistance is calculated from the shear characteristic resistance V
Rd,s
by V
Rd,s
=V
Rk,s
/
Ms
, where the partial
safety factor
Ms
is 1.25.



V
Rd
: System design shear resistance
V
Rd
: System design shear resistance
V
Rd
= lower of V
Rd,c
and V
Rd,s



Combined loading: Only if tensile load and shear load applied (See page 32 and section 4 Examples).
These results are for a two-.
Anchor fastening.

For fastening made with more
than 2 anchors, use the
general formulae for n
anchors at the top of the page.

HSL-3 Heavy Duty Sleeve Anchor 4.3.2
Mechanical Anchoring Systems












HSL-3 Heavy Duty Anchor HSL-3-B Heavy Duty Anchor with Torque Cap





HSL-3-G Heavy Duty Anchor with Threaded Rod




Metric Maximum fastened thickness (mm)

HSL-3-G M 12/25

Heavy duty blank-bolt Metric thread size (mm);
Sleeve (Expansion) G: stud not hole diameter
Anchor B: torque cap


4.3.2.1 Product Description
The Hilti HSL-3 Heavy Duty Sleeve Anchor is a torque-controlled expansion bolt
designed for high performance in static and dynamic application including
the tension zone of concrete structures where cracking can be expected. HSL-3
anchors are available in metric sizes from M8 (5/16) to M24 (1). With a variety
of head styles, including bolt, stud and torque cap. All versions are available in
zinc-plated carbon steel.


Product Features
Approved for use in the concrete tension zone (cracked concrete)
Data for use with the Strength design provisions of ACI 318-02 Appendix D and ACI 349-01 Appendix B
Allowable stress design data for use with ASD methods
High load capacity
Force-controlled expansion (allows for follow-up expansion)
Reliable pull-down of part fastened to overcome gaps
Suitable for dynamic loading, including seismic, fatigue and shock
No spinning of the anchor in hole when tightening bolt or nut
Seismic qualification per ICC-ES AC193 and the requirements of ACI 318-02 Appendix D


Guide Specification
Expansion Anchors: Carbon steel anchor consists of hex bolt (threaded stud), sleeve,
expansion sleeve, expansion cone, collapsible plastic sleeve, (nut) and washer. Anchors
shall be torque controlled expansion bolt as manufactured by Hilti, Inc., Tulsa, OK.


4.3.2.2 Material Specifications
Carbon Steel Bolt or Threaded Rod for HSL-3 (Bolt), HSL-3 (Stud) and HSL-3-B conform to DIN EN ISO 898-1,
Grade 8.8, fy > 93 ksi
Carbon Steel Nut conforms to DIN 934, Grade 8, fu > 116 ksi
Carbon Steel Washer conforms to DIN 1544, Grade St37, fu > 100 ksi
Carbon Steel Expansion Cone conforms to DIN 1654-4, fu > 80 ksi
Carbon Steel Expansion Sleeve conforms to DIN 1624
Carbon Steel Spacing Sleeve conforms to DIN 2393 T1, fu > 100 ksi
Collapsible Sleeve is made from acetal polyoxymethylene (POM) resin
Plastic collapsible
section with anchor
rotation prevention
Expansion
Sleeve
Cone
Spacer Sleeve
Minimum
Embedment
Mark
Bolt

Washer
Three accurately sized shear
pins are provided in the red
indicator cap. On applying the
required torque with an ordinary
wrench, the red indicator cap
shears off. The green seal on
the bolt head which appears
indicates that the anchor has
been properly set
4.3.2 HSL-3
4.3.2.1 Product Description
4.3.2.2 Material Specification
4.3.2.3 Technical Data
4.3.2.4 Edge and Spacing Distance
Guidelines for ASD Data
4.3.2.5 Installation Instructions
4.3.2.6 Ordering Information
Example: HSL-3-G M12/25
This is an HSL-3 stud anchor.
The thread size is 12 mm and
this anchor can attach up to a 25
mm thick plate
Red Setting Indicator

Listings/Approvals
International Code Council Evaluation
Services (ICC ES),
ESR-Pending
European Technical Approval,
ETA-02/0042
1

HSL-3 Heavy Duty Sleeve Anchor 4.3.2
Mechanical Anchoring Systems












HSL-3 Heavy Duty Anchor HSL-3-B Heavy Duty Anchor with Torque Cap





HSL-3-G Heavy Duty Anchor with Threaded Rod




Metric Maximum fastened thickness (mm)

HSL-3-G M 12/25

Heavy duty blank-bolt Metric thread size (mm);
Sleeve (Expansion) G: stud not hole diameter
Anchor B: torque cap


4.3.2.1 Product Description
The Hilti HSL-3 Heavy Duty Sleeve Anchor is a torque-controlled expansion bolt
designed for high performance in static and dynamic application including
the tension zone of concrete structures where cracking can be expected. HSL-3
anchors are available in metric sizes from M8 (5/16) to M24 (1). With a variety
of head styles, including bolt, stud and torque cap. All versions are available in
zinc-plated carbon steel.


Product Features
Approved for use in the concrete tension zone (cracked concrete)
Data for use with the Strength design provisions of ACI 318-02 Appendix D and ACI 349-01 Appendix B
Allowable stress design data for use with ASD methods
High load capacity
Force-controlled expansion (allows for follow-up expansion)
Reliable pull-down of part fastened to overcome gaps
Suitable for dynamic loading, including seismic, fatigue and shock
No spinning of the anchor in hole when tightening bolt or nut
Seismic qualification per ICC-ES AC193 and the requirements of ACI 318-02 Appendix D


Guide Specification
Expansion Anchors: Carbon steel anchor consists of hex bolt (threaded stud), sleeve,
expansion sleeve, expansion cone, collapsible plastic sleeve, (nut) and washer. Anchors
shall be torque controlled expansion bolt as manufactured by Hilti, Inc., Tulsa, OK.


4.3.2.2 Material Specifications
Carbon Steel Bolt or Threaded Rod for HSL-3 (Bolt), HSL-3 (Stud) and HSL-3-B conform to DIN EN ISO 898-1,
Grade 8.8, fy > 93 ksi
Carbon Steel Nut conforms to DIN 934, Grade 8, fu > 116 ksi
Carbon Steel Washer conforms to DIN 1544, Grade St37, fu > 100 ksi
Carbon Steel Expansion Cone conforms to DIN 1654-4, fu > 80 ksi
Carbon Steel Expansion Sleeve conforms to DIN 1624
Carbon Steel Spacing Sleeve conforms to DIN 2393 T1, fu > 100 ksi
Collapsible Sleeve is made from acetal polyoxymethylene (POM) resin
Plastic collapsible
section with anchor
rotation prevention
Expansion
Sleeve
Cone
Spacer Sleeve
Minimum
Embedment
Mark
Bolt

Washer
Three accurately sized shear
pins are provided in the red
indicator cap. On applying the
required torque with an ordinary
wrench, the red indicator cap
shears off. The green seal on
the bolt head which appears
indicates that the anchor has
been properly set
4.3.2 HSL-3
4.3.2.1 Product Description
4.3.2.2 Material Specification
4.3.2.3 Technical Data
4.3.2.4 Edge and Spacing Distance
Guidelines for ASD Data
4.3.2.5 Installation Instructions
4.3.2.6 Ordering Information
Example: HSL-3-G M12/25
This is an HSL-3 stud anchor.
The thread size is 12 mm and
this anchor can attach up to a 25
mm thick plate
Red Setting Indicator

Listings/Approvals
International Code Council Evaluation
Services (ICC ES),
ESR-Pending
European Technical Approval,
ETA-02/0042
1

HSL-3 Heavy Duty Sleeve Anchor 4.3.2
Mechanical Anchoring Systems

4.3.2.3 Technical Data
HSL-3 Specification Table
HSL-3 Anchor Thread Diameter (mm)
Details
M8 M10 M12 M16 M20 M24
nominal drill bit diameter
1
dbit mm 12 15 18 24 28 32
Hilti matched-tolerance carbide-
tipped drill bit
- -
TE-CX 12/22
TE-YX 12/35
TE-CX 15/27
TE-YX 15/35
TE-C 18/22
TE-YX 18/32
TE-C-T 24/27
TE-YX 24/32
TE-C-T 28/27
TE-YX 28/32
TE-YX 32/37
mm 110 (120) 120 (140) 135 (160) 160 (200) 190 (250) 225 (300)
minimum base material thickness (to
obtain smallest critical edge distance)
h
(in.) 4 3/8 (4 3/4) 4 3/4 (5 1/2) 5 3/8 (6 1/4) 6 1/4 (7 7/8) 7 1/2 (9 7/8) 8 7/8 (11 7/8)
mm 80 90 105 125 155 180
minimum hole depth ho
(in.) (3 1/8) (3 1/2) (4 1/8) (4 7/8) (6 1/8) (7 1/8)
mm 60 70 80 100 125 150
effective embedment depth hef
(in.) (2 3/8) (2 3/4) (3 1/8) (3 7/8) (4 7/8) (5 7/8)
mm 14-15 17-18 20-21 26-28 31-33 35-37
minimum clearance hole diameter in
part being fastened
dh
(in.) (1/2) (5/8) (3/4) (1) (1 1/4) (1 3/8)
mm 4 5 8 9 12 16
max. cumulative gap between part(s)
being fastened and concrete surface
-
(in.) (1/8) (3/16) (5/16) (3/8) (1/2) (5/8)
mm 20 40 20 40 25 50 25 50 30 60 30 60
maximum thickness of part fastened
HSL-3, HSL-3-B
t
(in.) (3/4) (1 ) (3/4) (1 ) (1) (2) (1) (2) (1 1/8) (2 1/4) (1 1/8) (2 1/4)
mm 98 118 110 130 131 156 153 178 183 213 205 235 overall length of anchor
HSL-3, HSL-3-B

(in.) (3 7/8) (4 5/8) (4 3/8) (5 1/8 (5 1/8) (6 1/8) (6) (7) (7 1/4) (8 3/8) (8) (9 1/4)
mm 20 40 25 50 25 50 30 60 maximum thickness of part fastened
HSL-3-G
t
(in.) (3/4) (1 ) (1) (2) (1) (2) (1 1/8) (2 1/4)

mm 102 115 139 164 163 188 190 220 overall length of anchor
HSL-3-G

(in.) (4) (4 ) (5 1/2) (6 3/8) (6 3/8) (7 3/8) (7 1/2) (8 3/4)

mm 20 25 30 40 45 50
washer diameter dw
(in.) (3/4) (1) (1 1/8) (1 9/16) (1 3/4) (2)
Nm 25 50 80 120 200 250
installation torque HSL-3 Tinst
(ft-lb) (18) (37) (59) (89) (148) (185)
Nm 20 35 60 80 160
installation torque HSL-3-G Tinst
(ft-lb) (15) (26) (44) (59) (118)
wrench size HSL-3, HSL-3-G - mm 13 17 19 24 30 36
wrench size HSL-3-B - mm 24 30 36 41
For pound-inch units: 1 mm = 0.03937 inches, 1 Nm = 0.735 ft-lbf
1
Use metric bits only.













2

HSL-3 Heavy Duty Sleeve Anchor 4.3.2
Mechanical Anchoring Systems

4.3.2.3 Technical Data
HSL-3 Specification Table
HSL-3 Anchor Thread Diameter (mm)
Details
M8 M10 M12 M16 M20 M24
nominal drill bit diameter
1
dbit mm 12 15 18 24 28 32
Hilti matched-tolerance carbide-
tipped drill bit
- -
TE-CX 12/22
TE-YX 12/35
TE-CX 15/27
TE-YX 15/35
TE-C 18/22
TE-YX 18/32
TE-C-T 24/27
TE-YX 24/32
TE-C-T 28/27
TE-YX 28/32
TE-YX 32/37
mm 110 (120) 120 (140) 135 (160) 160 (200) 190 (250) 225 (300)
minimum base material thickness (to
obtain smallest critical edge distance)
h
(in.) 4 3/8 (4 3/4) 4 3/4 (5 1/2) 5 3/8 (6 1/4) 6 1/4 (7 7/8) 7 1/2 (9 7/8) 8 7/8 (11 7/8)
mm 80 90 105 125 155 180
minimum hole depth ho
(in.) (3 1/8) (3 1/2) (4 1/8) (4 7/8) (6 1/8) (7 1/8)
mm 60 70 80 100 125 150
effective embedment depth hef
(in.) (2 3/8) (2 3/4) (3 1/8) (3 7/8) (4 7/8) (5 7/8)
mm 14-15 17-18 20-21 26-28 31-33 35-37
minimum clearance hole diameter in
part being fastened
dh
(in.) (1/2) (5/8) (3/4) (1) (1 1/4) (1 3/8)
mm 4 5 8 9 12 16
max. cumulative gap between part(s)
being fastened and concrete surface
-
(in.) (1/8) (3/16) (5/16) (3/8) (1/2) (5/8)
mm 20 40 20 40 25 50 25 50 30 60 30 60
maximum thickness of part fastened
HSL-3, HSL-3-B
t
(in.) (3/4) (1 ) (3/4) (1 ) (1) (2) (1) (2) (1 1/8) (2 1/4) (1 1/8) (2 1/4)
mm 98 118 110 130 131 156 153 178 183 213 205 235 overall length of anchor
HSL-3, HSL-3-B

(in.) (3 7/8) (4 5/8) (4 3/8) (5 1/8 (5 1/8) (6 1/8) (6) (7) (7 1/4) (8 3/8) (8) (9 1/4)
mm 20 40 25 50 25 50 30 60 maximum thickness of part fastened
HSL-3-G
t
(in.) (3/4) (1 ) (1) (2) (1) (2) (1 1/8) (2 1/4)

mm 102 115 139 164 163 188 190 220 overall length of anchor
HSL-3-G

(in.) (4) (4 ) (5 1/2) (6 3/8) (6 3/8) (7 3/8) (7 1/2) (8 3/4)

mm 20 25 30 40 45 50
washer diameter dw
(in.) (3/4) (1) (1 1/8) (1 9/16) (1 3/4) (2)
Nm 25 50 80 120 200 250
installation torque HSL-3 Tinst
(ft-lb) (18) (37) (59) (89) (148) (185)
Nm 20 35 60 80 160
installation torque HSL-3-G Tinst
(ft-lb) (15) (26) (44) (59) (118)
wrench size HSL-3, HSL-3-G - mm 13 17 19 24 30 36
wrench size HSL-3-B - mm 24 30 36 41
For pound-inch units: 1 mm = 0.03937 inches, 1 Nm = 0.735 ft-lbf
1
Use metric bits only.













2

HSL-3 Heavy Duty Sleeve Anchor 4.3.2
Mechanical Anchoring Systems
Allowable Stress Design Static Tension Loads for Uncracked Normal Weight Concrete
1,3

Concrete Compressive Strength
2

13.8 MPa
(2,000 psi)
20.7 MPa
(3,000 psi)
27.6 MPa
(4,000 psi)
41.4 MPa
(6,000 psi) Anchor
Diameter
Embedment
Depth
h
ef

mm
(in.)
Condition
A
kN (lb)
Condition
B
kN (lb)
Condition
A
kN (lb)
Condition
B
kN (lb)
Condition
A
kN (lb)
Condition
B
kN (lb)
Condition
A
kN (lb)
Condition
B
kN (lb)
7.8 7.8 9.5 9.5 11.0 11.0 13.5 13.5
M8
60
(2 3/8)
(1,746) (1,746) (2,139) (2,139) (2,470) (2,470) (3,025) (3,025)
11.7 10.1 14.3 12.4 12.1 14.3 20.3 17.6
M10
70
(2 3/4)
(2,631) (2,280) (3,222) (2,792) (3,720) (3,224) (4,556) (3,949)
14.3 12.4 17.5 15.2 20.2 17.5 24.8 21.6
M12
80
(3 1/8)
(3,214) (2,785) (3,936) (3,411) (4,545) (3,939) (5,567) (4,825)
20.0 17.3 24.5 21.2 28.3 24.5 34.6 30.0
M16
100
(3 15/16)
(4,492) (3,893) (5,501) (4,768) (6,352) (5,505) (7,780) (6,743)
27.9 24.2 34.2 29.6 39.5 34.2 48.4 41.9
M20
125
(4 15/16)
(6,277) (5,440) (7,688) (6,663) (8,877) (7,694) (10,873) (9,423)
36.7 31.8 50.0 39.0 51.9 45.0 63.6 55.1
M24
150
(5 15/16)
(8,252) (7,152) (10,106) (8,759) (11,670) (10,114) (14,292) (12,387)
For SI: 1 lbf = 4.45 N, 1 psi = 0.00689 MPa For pound-inch units: 1 mm = 0.03937 inches
1
Values are for single anchors with no edge distance or spacing reduction.
2
Values are for normal weight concrete. For sand-lightweight concrete, multiply values by 0.85. For all-lightweight concrete, multiply values by 0.75. See
ACI 318-02 Section D.3.4.
3
Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete
failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout
strength governs. See ACI 318-02 Appendix D section D.4.4



Allowable Stress Design Static Shear loads for Uncracked
Concrete
1
Allowable Steel Capacity, Shear
Anchor
Diameter HSL-3, HSL-3-B
kN (lb)
HSL-3-G
kN (lb)
M8
15.0
(3,361)
12.5
(2,818)
M10
21.1
(4,749)
17.3
(3,893)
M12
29.1
(6,837)
25.1
(5,647)
M16
55.2
(12,400)
46.8
(10,531)
M20
81.6
(18,349)
68.5
(15,395)
M24
94.9
(21,334)

For SI: 1 lbf = 4.45 N
1
Values are for single anchors with no edge distance or spacing reduction due to concrete failure.


3

HSL-3 Heavy Duty Sleeve Anchor 4.3.2
Mechanical Anchoring Systems

4.3.2.4 Edge and Spacing Distance Guidelines for ASD Data

Anchor Size h
ef
mm (in.)
M8 60 (2 3/8)
M10 70 (2 )
M12 80 (3 1/8)
M16 100 (3 15/16)
M20 125 (4 15/16)
M24 150 (5 15/16)



c = actual edge distance
s = actual spacing
h = slab thickness


M8 M10 M12 M16 M20 M24
60 (2 3/8) 0.69
70 (2 3/4) 0.72 0.67
79 (3 1/8) 0.75 0.69 0.67
89 (3 1/2) 0.77 0.71 0.68
102 (4) 0.81 0.74 0.71 0.67
127 (5) 0.88 0.80 0.75 0.71 0.67
152 (6) 0.95 0.86 0.81 0.75 0.70 0.67
171 (6 3/4) 1.00 0.91 0.86 0.79 0.73 0.69
178 (7) 0.92 0.87 0.80 0.74 0.69
203 (8) 0.98 0.91 0.84 0.77 0.72
213 (8 3/8) 1.00 0.93 0.86 0.78 0.74
229 (9) 0.96 0.88 0.80 0.75
254 (10) 1.00 0.92 0.84 0.78
279 (11) 0.96 0.87 0.81
305 (12) 1.00 0.91 0.84
330 (13) 0.94 0.87
381 (15) 1.00 0.92
457 (18) 1.00
Tension Load Adjustmant Factors for Anchor Spacing f
A
Anchor Diameter
Spacing
s
mm (in.)


M8 M10 M12 M16 M20 M24
60 (2 3/8) 0.63
70 (2 3/4) 0.69 0.71
83 (3 1/4) 0.78 0.79
89 (3 1/2) 0.83 0.83 0.80
102 (4) 0.95 0.92 0.88
108 (4 1/4) 1.00 0.97 0.92
111 (4 3/8) 1.00 0.94
121 (4 3/4) 1.00 0.85
127 (5) 0.88 0.63
140 (5 1/2) 0.95 0.67
149 (5 7/8) 1.00 0.70 0.75
165 (6 1/2) 0.75 0.80
178 (7) 0.80 0.84
191 (7 1/2) 0.84 0.88
203 (8) 0.90 0.92
225 (8 7/8) 1.00 1.00
Anchor Diameter
Tension Load Adjustment Factors for Edge Distance fR
Distance
c
mm (in.)
Notes:
Tension reduction factors are based on a minimum base material thickness of 2 x hef
Shear reduction factors are based on a thick base material at the edge (i.e. no influence from a thin base material)







4

HSL-3 Heavy Duty Sleeve Anchor 4.3.2
Mechanical Anchoring Systems
Edge Distance Guidelines for Shear Loading by Concrete Compressive Strength- Part 1

M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20 M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20
60 (2 3/8) 0.13 0.16 0.16 0.20
70 (2 3/4) 0.17 0.13 0.20 0.16 0.20 0.16 0.24 0.20
89 (3 1/2) 0.24 0.19 0.15 0.29 0.23 0.18 0.29 0.23 0.18 0.35 0.28 0.22
102 (4) 0.29 0.23 0.18 0.35 0.28 0.21 0.36 0.28 0.22 0.43 0.35 0.26
111 (4 3/8) 0.34 0.27 0.20 0.40 0.32 0.25 0.41 0.33 0.25 0.49 0.40 0.30
121 (4 3/4) 0.38 0.30 0.23 0.15 0.45 0.37 0.28 0.17 0.47 0.37 0.28 0.18 0.55 0.45 0.34 0.21
127 (5) 0.41 0.33 0.25 0.16 0.11 0.49 0.40 0.30 0.19 0.14 0.50 0.40 0.30 0.19 0.14 0.60 0.49 0.37 0.23 0.17
149 (5 7/8) 0.52 0.41 0.32 0.20 0.15 0.13 0.62 0.51 0.38 0.24 0.17 0.64 0.51 0.39 0.25 0.18 0.16 0.76 0.62 0.47 0.29 0.21
165 (6 1/2) 0.61 0.48 0.37 0.23 0.17 0.16 0.72 0.59 0.44 0.27 0.20 0.74 0.59 0.45 0.29 0.21 0.19 0.89 0.72 0.54 0.34 0.25
178 (7) 0.68 0.54 0.41 0.26 0.19 0.18 0.81 0.66 0.50 0.31 0.23 0.83 0.66 0.50 0.32 0.23 0.21 1.00 0.80 0.61 0.38 0.28
191 (7 1/2) 0.75 0.60 0.46 0.29 0.21 0.19 0.90 0.73 0.55 0.34 0.25 0.92 0.73 0.56 0.35 0.26 0.24 0.89 0.67 0.42 0.31
203 (8) 0.83 0.66 0.50 0.32 0.23 0.21 1.00 0.80 0.61 0.37 0.28 1.00 0.81 0.61 0.39 0.28 0.26 1.00 0.74 0.46 0.34
225 (8 7/8) 0.97 0.77 0.59 0.37 0.27 0.25 0.94 0.71 0.44 0.32 0.94 0.72 0.46 0.33 0.31 0.87 0.54 0.40
229 (9) 1.00 0.79 0.60 0.38 0.28 0.26 0.96 0.72 0.45 0.33 0.96 0.73 0.46 0.34 0.31 0.89 0.55 0.41
235 (9 1/4) 0.82 0.62 0.40 0.29 0.27 1.00 0.75 0.47 0.34 1.00 0.76 0.48 0.35 0.33 0.92 0.57 0.42
248 (9 3/4) 0.89 0.67 0.43 0.31 0.29 0.82 0.50 0.37 0.83 0.52 0.38 0.35 1.00 0.62 0.46
254 (10) 0.92 0.70 0.44 0.32 0.30 0.85 0.52 0.39 0.86 0.54 0.40 0.37 0.64 0.47
267 (10 1/2) 1.00 0.76 0.49 0.35 0.33 0.93 0.57 0.42 0.94 0.59 0.43 0.40 0.70 0.55
279 (11) 0.81 0.51 0.37 0.35 0.98 0.60 0.45 1.00 0.63 0.46 0.42 0.74 0.56
286 (11 1/4) 0.84 0.53 0.39 0.36 1.00 0.62 0.46 0.65 0.47 0.44 0.76 0.57
305 (12) 0.92 0.58 0.43 0.39 0.69 0.51 0.72 0.52 0.48 0.84 0.62
324 (12 3/4) 1.00 0.64 0.47 0.43 0.75 0.56 0.78 0.57 0.53 0.92 0.68
330 (13) 0.66 0.48 0.44 0.78 0.57 0.81 0.59 0.54 0.95 0.70
343 (13 1/2) 0.70 0.51 0.47 0.78 0.57 0.85 0.62 0.57 1.00 0.74
356 (14) 0.74 0.54 0.50 0.87 0.64 0.90 0.66 0.61 0.79
381 (15) 0.82 0.60 0.55 0.96 0.71 1.00 0.73 0.67 0.87
391 (15 3/8) 0.85 0.62 0.57 1.00 0.74 0.76 0.70 0.91
406 (16) 0.90 0.66 0.61 0.78 0.81 0.74 0.96
419 (16 1/2) 0.94 0.69 0.63 0.82 0.84 0.78 1.00
438 (17 1/4) 1.00 0.74 0.68 0.88 0.90 0.83
457 (18) 0.78 0.72 0.94 0.96 0.88
470 (18 1/2) 0.82 0.75 0.97 1.00 0.92
483 (19) 0.85 0.78 1.00 0.96
495 (19 1/2) 0.88 0.81 1.00
508 (20) 0.92 0.85
533 (21) 1.00 0.91
559 (22) 0.98
565 (22 1/4) 1.00
Anchor Diameter Anchor Diameter Anchor Diameter Anchor Diameter
HSL-3, HSL-3-B HSL-3-G HSL-3, HSL-3-B HSL-3-G
Load Adjustment Factors, f
R
, for Shear Loading Toward the Edge (single anchor)
13.8 MPa (2,000 psi) 20.7 MPa (3,000 psi)
Edge Distance
c
mm (in.)
1

Does not include effects of thin base materials at the edge.
5

HSL-3 Heavy Duty Sleeve Anchor 4.3.2
Mechanical Anchoring Systems
Edge Distance Guidelines for Shear Loading by Concrete Compressive Strength Part 2

M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20 M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20
60 (2 3/8) 0.19 0.23 0.23 0.28
70 (2 3/4) 0.24 0.19 0.28 0.23 0.29 0.23 0.35 0.28
89 (3 1/2) 0.34 0.27 0.21 0.41 0.33 0.25 0.42 0.33 0.25 0.50 0.40 0.30
102 (4) 0.41 0.33 0.25 0.49 0.40 0.30 0.51 0.40 0.31 0.61 0.49 0.37
111 (4 3/8) 0.47 0.38 0.29 0.57 0.46 0.35 0.58 0.46 0.35 0.69 0.56 0.43
121 (4 3/4) 0.54 0.43 0.32 0.21 0.64 0.52 0.39 0.24 0.66 0.52 0.40 0.25 0.78 0.64 0.48 0.30
127 (5) 0.58 0.46 0.35 0.22 0.16 0.69 0.56 0.42 0.26 0.19 0.71 0.56 0.43 0.27 0.20 0.85 0.69 0.52 0.32 0.24
140 (5 1/2) 0.69 0.54 0.42 0.26 0.19 0.82 0.66 0.50 0.31 0.23 0.84 0.67 0.51 0.32 0.24 1.00 0.81 0.62 0.38 0.28
149 (5 7/8) 0.74 0.59 0.45 0.28 0.21 0.19 0.88 0.71 0.54 0.33 0.25 0.90 0.72 0.55 0.35 0.25 0.23 0.87 0.66 0.41 0.30
159 (6 1/4) 0.82 0.65 0.50 0.31 0.23 0.21 0.98 0.79 0.60 0.37 0.27 1.00 0.80 0.61 0.39 0.28 0.26 0.97 0.73 0.45 0.34
162 (6 3/8) 0.84 0.67 0.51 0.32 0.24 0.22 1.00 0.81 0.61 0.38 0.28 0.82 0.62 0.39 0.29 0.27 1.00 0.75 0.46 0.34
165 (6 1/2) 0.86 0.68 0.52 0.33 0.24 0.22 0.83 0.63 0.39 0.29 0.83 0.64 0.40 0.29 0.27 0.77 0.48 0.35
178 (7) 0.96 0.76 0.58 0.37 0.27 0.25 0.93 0.70 0.43 0.32 0.93 0.71 0.45 0.33 0.30 0.86 0.53 0.39
181 (7 1/8) 1.00 0.79 0.61 0.38 0.28 0.26 0.97 0.73 0.45 0.33 0.97 0.74 0.47 0.34 0.32 0.90 0.55 0.41
187 (7 3/8) 0.82 0.62 0.40 0.29 0.27 1.00 0.76 0.47 0.35 1.00 0.76 0.49 0.35 0.33 0.93 0.57 0.42
191 (7 1/2) 0.84 0.64 0.41 0.30 0.27 0.78 0.48 0.36 0.79 0.50 0.37 0.34 0.95 0.59 0.44
197 (7 3/4) 0.89 0.68 0.43 0.31 0.29 0.82 0.51 0.37 0.83 0.53 0.38 0.35 1.00 0.62 0.46
203 (8) 0.93 0.71 0.45 0.33 0.30 0.86 0.53 0.39 0.87 0.55 0.40 0.37 0.65 0.48
216 (8 1/2) 1.00 0.78 0.49 0.36 0.33 0.94 0.58 0.43 0.95 0.60 0.44 0.41 0.71 0.53
225 (8 7/8) 0.83 0.53 0.38 0.35 1.00 0.62 0.46 1.00 0.64 0.47 0.43 0.76 0.56
254 (10) 1.00 0.63 0.46 0.42 0.74 0.55 0.77 0.56 0.52 0.91 0.67
270 (10 5/8) 0.70 0.51 0.47 0.82 0.61 0.85 0.62 0.57 1.00 0.74
279 (11) 0.73 0.53 0.49 0.85 0.63 0.89 0.65 0.60 0.77
305 (12) 0.83 0.60 0.56 0.97 0.72 1.00 0.74 0.68 0.88
311 (12 1/4) 0.85 0.62 0.57 1.00 0.74 0.76 0.70 0.91
318 (12 1/2) 0.88 0.64 0.59 0.77 0.79 0.72 0.94
330 (13) 0.93 0.68 0.63 0.81 0.83 0.77 1.00
343 (13 1/2) 1.00 0.73 0.67 0.87 0.89 0.77
356 (14) 0.76 0.70 0.91 0.93 0.86
371 (14 5/8) 0.82 0.75 0.98 1.00 0.92
381 (15) 0.84 0.78 1.00 0.95
394 (15 1/2) 0.89 0.82 1.00
406 (16) 0.93 0.86
425 (16 3/4) 1.00 0.92
448 (17 5/8) 1.00
Anchor Diameter Anchor Diameter Anchor Diameter Anchor Diameter
HSL-3, HSL-3-B HSL-3G HSL-3, HSL-3-B
27.6 MPa (4,000 psi) 41.4 MPa (6,000 psi)
Load Adjustment Factors, f
R
, for Shear Loading Toward the Edge (single anchor)
Edge Distance
c
mm (in.)
HSL-3G
1

Does not include effects of thin base materials at the edge.
6

HSL-3 Heavy Duty Sleeve Anchor 4.3.2
Mechanical Anchoring Systems
7
4.3.2.5 Installation Instructions
.



















Step 3:
Using a hammer, tap the anchor through
the part being fastened into the drilled hole
until the washer is in contact with the
fastened part. Do not expand anchor by
hand prior to installation.
Step 2:
Remove drilling debris with a
blowout bulb or with
compressed air.
Step 1:
Using the correct diameter
metric bit, drill hole to minimum
required hole depth or deeper.
Step 4:
Using a torque wrench, apply the
specified installation torque. HSL-3-
B does not require use of a torque
wrench.


4.3.2.6 Ordering Information




HSL-3 Bolt Version HSL-3-B Torque Cap HSL-3-G Stud Version

Item No. Description Box Qty Item No. Description Box Qty Item No. Description Box Qty
371775 HSL-3 M 8/20 40 371807 HSL-3-B M 12/5 20 371793 HSL-3-G M 8/20 40
371776 HSL-3 M 8/40 40 371808 HSL-3-B M 12/25 20 371796 HSL-3-G M 10/20 20
371778 HSL-3 M 10/20 20 371809 HSL-3-B M 12/50 10 371799 HSL-3-G M 12/25 20
371779 HSL-3 M 10/40 20 371810 HSL-3-B M 16/10 10 371800 HSL-3-G M 12/50 10
371781 HSL-3 M 12/25 20 371811 HSL-3-B M 16/25 10 371802 HSL-3-G M 16/25 10
371782 HSL-3 M 12/50 20 371814 HSL-3-B M 20/30 6 371803 HSL-3-G M 16/50 10
371784 HSL-3 M 16/25 10 371817 HSL-3-B M 24/30 4 371805 HSL-3-G M 20/30 6
371785 HSL-3 M 16/50 10 371806 HSL-3-G M 20/60 6
371787 HSL-3 M 20/30 6
371788 HSL-3 M 20/60 6
371790 HSL-3 M 24/30 4
371791 HSL-3 M 24/60 4


HSL-G-R heavy-duty anchor
61
Features:
- high loading capacity
- force-controlled expansion
- reliable pull-down of part fastened
- no rotation in hole when tightening bolt
Bolt Material:
- X5CrNiMo1810, 1.4401, A4-70 DIN 267 T11
Version:
HSL-G-R: - nut
Basic loading data (for a single anchor): HSL-G-R
All data on this section applies to
x concrete, f
cc
= 30 N/mm
2
x no edge distance and spacing influence
x correct setting (See setting operations page 65)
Characteristic resistance, R
k
[kN]:
Anchor size
Concrete,
f
cc
[N/mm
2
]
M8 M10 M12 M16 M20
20 21.3 29.5 34.3 52.5 80.9
30 22.5 32.7 41.4 66.7 102.3
40 23.8 35.8 48.4 80.8 123.6
50 25.0 39.0 55.5 95.0 145.0
Tensile, N
Rk
55 25.6 40.6 59.0 102.1 155.7
Shear, V
Rk t 20 23.1 36.5 53.1 99.0 154.4
safety concept (EUROCODE 1)
M
k
d d F
R
R S S
J
d J
S actual load
S
d
design action (load)
R
d
design resistance (anchor)
R
k
characteristic anchor resistance
N
Rk
tensile load
V
Rk
shear load
J
F
partial safety factor (action / load) = 1.4
J
M
partial safety factor (resistance) = 2.15 (concrete)
1.60 (steel)
non-cracked concrete
HSL-G-R
A4
316
Concrete
Hilti Anchor
programme
Fire resistance
Corrosion
resistance

Small edge
distance /
spacing

HSL-G-R heavy-duty anchor
62
Design resistance, R
d
[kN]: f
cc
= 30 N/mm
2
Anchor size M8 M10 M12 M16 M20
Tensile, N
Rd
0 10.4 15.1 19.1 30.9 47.3
30 11.9 17.9 24.1 41.8 64.6
45 12.6 19.3 26.6 47.3 73.3
Combined
load
60 13.4 20.7 29.1 52.7 82.0
Shear, V
Rd
90 14.9 23.5 34.1 63.6 99.3
Recommended load, F
30
in [kN], f
cc
= 30 N/mm
2
Anchor size M8 M10 M12 M16 M20
Tensile, N
Rec
0 7.5 10.9 13.8 22.2 34.1
30 8.5 12.8 17.3 30.0 46.3
45 9.1 13.8 19.1 33.8 52.5
Combined
load
60 9.6 14.8 20.8 37.7 58.6
Shear, V
Rec
90 10.6 16.7 24.4 45.4 70.8
Recommended load for specific application
R A T B 30 rec
f f f f F F
f
T
: Influence of anchorage depth
nom
act
T
h
h
f
nom act nom
h 1.5 h h d d h
act
actual anchorage depth
Anchor size M8 M10 M12 M16 M20
h
nom
[mm] 65 75 80 105 130
f
B
: Influence of concrete strength
Anchor size
Concrete,
f
cc
[N/mm
2
]
M8 M10 M12 M16 M20
20 7.1 9.8 11.4 17.5 27.0
30 7.5 10.9 13.8 22.2 34.1
40 7.9 11.9 16.1 26.9 41.2
50 8.3 13.0 18.5 31.7 48.3
Tensile
55 8.5 13.5 19.7 34.0 51.9
Shear t 20 10.6 16.7 24.4 45.4 70.8
F
N
V
s
c
h
2
HSL-G-R heavy-duty anchor
63
f
A
: Influence of anchor spacing
Tensile / Shear
Anchor spacing, HSL-G-R
s [mm] M8 M10 M12 M16 M20
65 0.70
75 0.72 0.70
80 0.73 0.71 0.70
105 0.79 0.76 0.74 0.70
130 0.85 0.81 0.79 0.73 0.70
155 0.90 0.86 0.84 0.77 0.72
175 0.95 0.90 0.87 0.80 0.75
195 1.0 0.94 0.91 0.82 0.77
225 1.0 0.97 0.87 0.80
240 1.0 0.89 0.82
275 1.0 0.94 0.86
315 1.0 0.91
350 1.0 0.95
395 1.0
430 1.0
f
R
: Influence of edge distance
Tensile, f
RN
Shear, f
RV
Edge distance, Anchor size Anchor size
c [mm] M8 M10 M12 M16 M20 M8 M10 M12 M16 M20
65 0.70 0.30
75 0.73 0.70 0.37 0.30
80 0.75 0.71 0.70 0.40 0.44 0.30
105 0.82 0.78 0.76 0.70 0.59 0.59 0.44 0.30
130 0.90 0.85 0.83 0.74 0.70 0.77 0.74 0.59 0.41 0.30
155 0.97 0.91 0.88 0.79 0.73 0.95 0.78 0.74 0.52 0.39
162 1.0 0.93 0.90 0.80 0.75 1.0 0.85 0.78 0.55 0.41
187 1.0 0.96 0.85 0.78 1.0 0.92 0.66 0.50
200 1.0 0.88 0.80 1.0 0.72 0.55
225 1.0 0.92 0.84 1.0 0.83 0.64
265 1.0 0.91 1.0 0.79
275 1.0 0.92 1.0 0.82
300 1.0 0.96 1.0 0.91
325 1.0 1.0
350 1.0 1.0
c
min
= h
nom
, c
cr
= 2.5h
act.
c
min
= h
nom
, c
cr
= 2.5h
nom
For combined loads with influence of edge distance:
90
) f f ( f f
RV RN RN R
D

D
There must be reinforcement in the edge of a concrete component which can take up 0.25 times the anchor load
if the edge distance is equal to or less than c
cr
.
55 . 0
h
s
15 . 0 f
. act
A

S
min
= h
nom
, s
cr
= 3h
act.
Separate multiple-anchor fastenings
must be at least a t 2 s
cr
apart to
ensure they do not influence each
other.
5 . 0
h
c
2 . 0 f
. act
RN
17 . 0
h
c
47 . 0 f
nom
RV

HSL-G-R heavy-duty anchor
64
Setting details
d
h
d
o
d
w
l
h
h
1
h
ef
h
n
t
fix
T
inst
HSL-G-R
Anchor size HSLG-R
Setting Details
M

8
/
2
0

M

1
0
/
2
0

M

1
2
/
2
5

M

1
6
/
2
5

M

2
0
/
3
0

d
0
[mm] Drill bit diameter 12 15 18 24 28
h
1
[mm] Hole depth 80 90 100 125 155
h
nom
[mm] Min. anchorage depth 65 75 80 105 130
t
fix
[mm] Max. fixture thickness 20 20 25 25 30
l [mm] Anchor length 102 115 125 157 190
h
n
[mm] Head height + washer 9.5 12.0 15.0 18.0 22.0
T
inst
[Nm] Tightening torque 25 40 80 120 200
Max. gap [mm] 4 5 8 9 12
S
w
[mm] Width across flats 13 17 19 24 30
d
h
[mm] Clearance hole 14 17 20 26 31
d
w
[mm] Washer diameter 20 25 30 40 45
h [mm] Min. base material thickness 120 140 160 180 220
Drill bit TE-CX- 12/22 15/27 - - -
Drill bit TE-T- - - 18/32 24/32 28/32
Installation equipment
Rotary hammer (TE1, TE2, TE5, TE6, TE6A, TE15, TE15-C, TE18-M, TE35, TE55, TE76), a hammer and a
torque wrench.
h
nom
2
HSL-G-R heavy-duty anchor
61
Features:
- high loading capacity
- force-controlled expansion
- reliable pull-down of part fastened
- no rotation in hole when tightening bolt
Bolt Material:
- X5CrNiMo1810, 1.4401, A4-70 DIN 267 T11
Version:
HSL-G-R: - nut
Basic loading data (for a single anchor): HSL-G-R
All data on this section applies to
x concrete, f
cc
= 30 N/mm
2
x no edge distance and spacing influence
x correct setting (See setting operations page 65)
Characteristic resistance, R
k
[kN]:
Anchor size
Concrete,
f
cc
[N/mm
2
]
M8 M10 M12 M16 M20
20 21.3 29.5 34.3 52.5 80.9
30 22.5 32.7 41.4 66.7 102.3
40 23.8 35.8 48.4 80.8 123.6
50 25.0 39.0 55.5 95.0 145.0
Tensile, N
Rk
55 25.6 40.6 59.0 102.1 155.7
Shear, V
Rk t 20 23.1 36.5 53.1 99.0 154.4
safety concept (EUROCODE 1)
M
k
d d F
R
R S S
J
d J
S actual load
S
d
design action (load)
R
d
design resistance (anchor)
R
k
characteristic anchor resistance
N
Rk
tensile load
V
Rk
shear load
J
F
partial safety factor (action / load) = 1.4
J
M
partial safety factor (resistance) = 2.15 (concrete)
1.60 (steel)
non-cracked concrete
HSL-G-R
A4
316
Concrete
Hilti Anchor
programme
Fire resistance
Corrosion
resistance

Small edge
distance /
spacing

HSL-G-R heavy-duty anchor
62
Design resistance, R
d
[kN]: f
cc
= 30 N/mm
2
Anchor size M8 M10 M12 M16 M20
Tensile, N
Rd
0 10.4 15.1 19.1 30.9 47.3
30 11.9 17.9 24.1 41.8 64.6
45 12.6 19.3 26.6 47.3 73.3
Combined
load
60 13.4 20.7 29.1 52.7 82.0
Shear, V
Rd
90 14.9 23.5 34.1 63.6 99.3
Recommended load, F
30
in [kN], f
cc
= 30 N/mm
2
Anchor size M8 M10 M12 M16 M20
Tensile, N
Rec
0 7.5 10.9 13.8 22.2 34.1
30 8.5 12.8 17.3 30.0 46.3
45 9.1 13.8 19.1 33.8 52.5
Combined
load
60 9.6 14.8 20.8 37.7 58.6
Shear, V
Rec
90 10.6 16.7 24.4 45.4 70.8
Recommended load for specific application
R A T B 30 rec
f f f f F F
f
T
: Influence of anchorage depth
nom
act
T
h
h
f
nom act nom
h 1.5 h h d d h
act
actual anchorage depth
Anchor size M8 M10 M12 M16 M20
h
nom
[mm] 65 75 80 105 130
f
B
: Influence of concrete strength
Anchor size
Concrete,
f
cc
[N/mm
2
]
M8 M10 M12 M16 M20
20 7.1 9.8 11.4 17.5 27.0
30 7.5 10.9 13.8 22.2 34.1
40 7.9 11.9 16.1 26.9 41.2
50 8.3 13.0 18.5 31.7 48.3
Tensile
55 8.5 13.5 19.7 34.0 51.9
Shear t 20 10.6 16.7 24.4 45.4 70.8
F
N
V
s
c
h
2
HSL-G-R heavy-duty anchor
63
f
A
: Influence of anchor spacing
Tensile / Shear
Anchor spacing, HSL-G-R
s [mm] M8 M10 M12 M16 M20
65 0.70
75 0.72 0.70
80 0.73 0.71 0.70
105 0.79 0.76 0.74 0.70
130 0.85 0.81 0.79 0.73 0.70
155 0.90 0.86 0.84 0.77 0.72
175 0.95 0.90 0.87 0.80 0.75
195 1.0 0.94 0.91 0.82 0.77
225 1.0 0.97 0.87 0.80
240 1.0 0.89 0.82
275 1.0 0.94 0.86
315 1.0 0.91
350 1.0 0.95
395 1.0
430 1.0
f
R
: Influence of edge distance
Tensile, f
RN
Shear, f
RV
Edge distance, Anchor size Anchor size
c [mm] M8 M10 M12 M16 M20 M8 M10 M12 M16 M20
65 0.70 0.30
75 0.73 0.70 0.37 0.30
80 0.75 0.71 0.70 0.40 0.44 0.30
105 0.82 0.78 0.76 0.70 0.59 0.59 0.44 0.30
130 0.90 0.85 0.83 0.74 0.70 0.77 0.74 0.59 0.41 0.30
155 0.97 0.91 0.88 0.79 0.73 0.95 0.78 0.74 0.52 0.39
162 1.0 0.93 0.90 0.80 0.75 1.0 0.85 0.78 0.55 0.41
187 1.0 0.96 0.85 0.78 1.0 0.92 0.66 0.50
200 1.0 0.88 0.80 1.0 0.72 0.55
225 1.0 0.92 0.84 1.0 0.83 0.64
265 1.0 0.91 1.0 0.79
275 1.0 0.92 1.0 0.82
300 1.0 0.96 1.0 0.91
325 1.0 1.0
350 1.0 1.0
c
min
= h
nom
, c
cr
= 2.5h
act.
c
min
= h
nom
, c
cr
= 2.5h
nom
For combined loads with influence of edge distance:
90
) f f ( f f
RV RN RN R
D

D
There must be reinforcement in the edge of a concrete component which can take up 0.25 times the anchor load
if the edge distance is equal to or less than c
cr
.
55 . 0
h
s
15 . 0 f
. act
A

S
min
= h
nom
, s
cr
= 3h
act.
Separate multiple-anchor fastenings
must be at least a t 2 s
cr
apart to
ensure they do not influence each
other.
5 . 0
h
c
2 . 0 f
. act
RN
17 . 0
h
c
47 . 0 f
nom
RV

HSL-G-R heavy-duty anchor
64
Setting details
d
h
d
o
d
w
l
h
h
1
h
ef
h
n
t
fix
T
inst
HSL-G-R
Anchor size HSLG-R
Setting Details
M

8
/
2
0

M

1
0
/
2
0

M

1
2
/
2
5

M

1
6
/
2
5

M

2
0
/
3
0

d
0
[mm] Drill bit diameter 12 15 18 24 28
h
1
[mm] Hole depth 80 90 100 125 155
h
nom
[mm] Min. anchorage depth 65 75 80 105 130
t
fix
[mm] Max. fixture thickness 20 20 25 25 30
l [mm] Anchor length 102 115 125 157 190
h
n
[mm] Head height + washer 9.5 12.0 15.0 18.0 22.0
T
inst
[Nm] Tightening torque 25 40 80 120 200
Max. gap [mm] 4 5 8 9 12
S
w
[mm] Width across flats 13 17 19 24 30
d
h
[mm] Clearance hole 14 17 20 26 31
d
w
[mm] Washer diameter 20 25 30 40 45
h [mm] Min. base material thickness 120 140 160 180 220
Drill bit TE-CX- 12/22 15/27 - - -
Drill bit TE-T- - - 18/32 24/32 28/32
Installation equipment
Rotary hammer (TE1, TE2, TE5, TE6, TE6A, TE15, TE15-C, TE18-M, TE35, TE55, TE76), a hammer and a
torque wrench.
h
nom
2
HSL-G-R heavy-duty anchor
65
Drill hole with drill bit. Blow out dust and fragments. Install anchor.
Apply tightening torque
Anchor mechanical properties
Anchor size HSL-G-R M 8 M 10 M 12 M 16 M 20
f
uk
[N/mm
2
] Nominal tensile strength 700 700 700 700 700
f
yk
[N/mm
2
] Yield strength 450 450 450 450 450
A
s
[mm
2
] Stressed cross-section 36.6 58.0 84.3 157 245
W [mm
3
] Effective moment of resistance 106 231 390 965 1421
M
d
[Nm] Design bending moment 41 90 150 375 550
HSL-G-R heavy-duty anchor
65
Drill hole with drill bit. Blow out dust and fragments. Install anchor.
Apply tightening torque
Anchor mechanical properties
Anchor size HSL-G-R M 8 M 10 M 12 M 16 M 20
f
uk
[N/mm
2
] Nominal tensile strength 700 700 700 700 700
f
yk
[N/mm
2
] Yield strength 450 450 450 450 450
A
s
[mm
2
] Stressed cross-section 36.6 58.0 84.3 157 245
W [mm
3
] Effective moment of resistance 106 231 390 965 1421
M
d
[Nm] Design bending moment 41 90 150 375 550
HSL-I heavy duty anchor
66 Issue 2005
Basic loading data (for a single anchor): HSL-I
All data on this page applies to
- concrete: as specified in the table
- no edge distance and spacing influence
- correct setting (See setting operations page 68)
- steel failure
Characteristic resistance, R
k
[kN]: concrete = C20/25
Anchor size M12 M12
h
nom 65 80
Tensile N
Rk
26.0 34.0
Shear V
Rk
34.0 34.0
Following values according to the
Concrete Capacity Method
Design resistance, R
d
[kN]: concrete f
ck,cube
=25N/mm
2
Anchor size M12 M12
h
nom 65 80
Tensile N
Rd
17.3 22.7
Shear V
Rd
27.2 27.2
Recommended load L
rec
[kN]: concrete f
ck,cube
=25N/mm
2
Anchor size M12 M12
h
nom 65 80
Tensile N
Rec
12.4 16.2
Shear V
Rec
19.4 19.4
non-cracked concrete
Features:
- high loading capacity
- force controlled expansion
- no rotation in hole when tightening torque
Material:
Nut: - carbon steel, grade 8.8
Washer: - carbon steel acc. ASTM F 844
Anchor Body: - carbon steel, grade 8.8
Cone: - carbon steel C45PB
Expansion Sleeve: - ST 52-3
Threaded Rod: - grade 8.8
Star washer: - stainless steel
Bolt material:
- grade 8.8 acc. DIN EN ISO 898-1 galvanised
to min.5 microns
Versions:
-HSL-I M12/0*65
-HSL-I M12/0*80
HSL-I
Concrete Hilti
Anchor
programme
HSL-I heavy duty anchor
Issue 2005 67
2
Setting details
HSL-I
HSL-I M12x65 HSL-I M12x80
d
0
Nominal bit diameter
(mm) 18 18
(mm) 65 80
h
nom
embedment depth
(in.) 2.56 3.15
(mm) 80 95
h
1
Hole depth
(in.) 3.15 3.74
(mm) 130 160
h
min
;
minimum base
material thickness
(in.) 5 1/8 6 1/4
(mm) 20 20
d
h
wedge clearance hole
in plate
(in.) 0.79 0.79
(Nm) 80 80
T
inst
Installation Torque
(ft/*lb) 60 60
Wrench size (for nut)
(mm) 19 19
allen wrench size (for socket)
(mm) 6 6
Washer diameter (mm) 30 30
Installation equipment
Rotary hammer (TE1, TE2, TE5, TE6, TE6A, TE15, TE15-C, TE18-M or TE35), a blow out pump,
h
min
h
1
h
ef
h
min
HSL-I heavy duty anchor
68 Issue 2005
Drill hole. Remove dust
and debris
using
compressed
air or blow
pump.
Hammer in
anchor.
Insert Allen
wrench into the
anchor.
Turn the Allen
wrench until
resistance is
exerted.
Place fixture
and insert the
threaded rod
into the anchor.
Using the
appropriate torque
nut, apply torque
until the upper
section of torque
nut shears of.
Detailed design method - Hilti CC
TENSION
The tensile design resistance of a single anchor
is the lower of,
N
Rd,p
: concrete pull-out resistance
N
Rd,c
: concrete cone resistance
N
Rd,s
: steel resistance
N
Rd,p
: Pull-out resistance
- Pull-out failure mode not determinating
N
Rd,c
: Concrete cone resistance
RN AN B
o
c , Rd c , Rd
f f f N N
Setting operations
HSL-I heavy duty anchor
66 Issue 2005
Basic loading data (for a single anchor): HSL-I
All data on this page applies to
x concrete: as specified in the table
x no edge distance and spacing influence
x correct setting (See setting operations page 68)
x steel failure
Characteristic resistance, R
k
[kN]: concrete # C20/25
Anchor size M12 M12
h
nom 65 80
Tensile N
Rk
26.0 34.0
Shear V
Rk
34.0 34.0
Following values according to the
Concrete Capacity Method
Design resistance, R
d
[kN]: concrete f
ck,cube
=25N/mm
2
Anchor size M12 M12
h
nom 65 80
Tensile N
Rd
17.3 22.7
Shear V
Rd
27.2 27.2
Recommended load L
rec
[kN]: concrete f
ck,cube
=25N/mm
2
Anchor size M12 M12
h
nom 65 80
Tensile N
Rec
12.4 16.2
Shear V
Rec
19.4 19.4
non-cracked concrete
Features:
- high loading capacity
- force controlled expansion
- no rotation in hole when tightening torque
Material:
Nut: - carbon steel, grade 8.8
Washer: - carbon steel acc. ASTM F 844
Anchor Body: - carbon steel, grade 8.8
Cone: - carbon steel C45PB
Expansion Sleeve: - ST 52-3
Threaded Rod: - grade 8.8
Star washer: - stainless steel
Bolt material:
- grade 8.8 acc. DIN EN ISO 898-1 galvanised
to min.5 microns
Versions:
-HSL-I M12/0*65
-HSL-I M12/0*80
HSL-I
Concrete Hilti
Anchor
programme
HSL-I heavy duty anchor
Issue 2005 67
2
Setting details
HSL-I
HSL-I M12x65 HSL-I M12x80
d
0
Nominal bit diameter
(mm) 18 18
(mm) 65 80
h
nom
embedment depth
(in.) 2.56 3.15
(mm) 80 95
h
1
Hole depth
(in.) 3.15 3.74
(mm) 130 160
h
min
;
minimum base
material thickness
(in.) 5 1/8 6 1/4
(mm) 20 20
d
h
wedge clearance hole
in plate
(in.) 0.79 0.79
(Nm) 80 80
T
inst
Installation Torque
(ft/*lb) 60 60
Wrench size (for nut)
(mm) 19 19
allen wrench size (for socket)
(mm) 6 6
Washer diameter (mm) 30 30
Installation equipment
Rotary hammer (TE1, TE2, TE5, TE6, TE6A, TE15, TE15-C, TE18-M or TE35), a blow out pump,
h
min
h
1
h
ef
h
min
HSL-I heavy duty anchor
68 Issue 2005
Drill hole. Remove dust
and debris
using
compressed
air or blow
pump.
Hammer in
anchor.
Insert Allen
wrench into the
anchor.
Turn the Allen
wrench until
resistance is
exerted.
Place fixture
and insert the
threaded rod
into the anchor.
Using the
appropriate torque
nut, apply torque
until the upper
section of torque
nut shears of.
Detailed design method - Hilti CC
TENSION
The tensile design resistance of a single anchor
is the lower of,
N
Rd,p
: concrete pull-out resistance
N
Rd,c
: concrete cone resistance
N
Rd,s
: steel resistance
N
Rd,p
: Pull-out resistance
x Pull-out failure mode not determinating
N
Rd,c
: Concrete cone resistance
RN AN B
o
c , Rd c , Rd
f f f N N
Setting operations
HSL-I heavy duty anchor
66 Issue 2005
Basic loading data (for a single anchor): HSL-I
All data on this page applies to
x concrete: as specified in the table
x no edge distance and spacing influence
x correct setting (See setting operations page 68)
x steel failure
Characteristic resistance, R
k
[kN]: concrete # C20/25
Anchor size M12 M12
h
nom 65 80
Tensile N
Rk
26.0 34.0
Shear V
Rk
34.0 34.0
Following values according to the
Concrete Capacity Method
Design resistance, R
d
[kN]: concrete f
ck,cube
=25N/mm
2
Anchor size M12 M12
h
nom 65 80
Tensile N
Rd
17.3 22.7
Shear V
Rd
27.2 27.2
Recommended load L
rec
[kN]: concrete f
ck,cube
=25N/mm
2
Anchor size M12 M12
h
nom 65 80
Tensile N
Rec
12.4 16.2
Shear V
Rec
19.4 19.4
non-cracked concrete
Features:
- high loading capacity
- force controlled expansion
- no rotation in hole when tightening torque
Material:
Nut: - carbon steel, grade 8.8
Washer: - carbon steel acc. ASTM F 844
Anchor Body: - carbon steel, grade 8.8
Cone: - carbon steel C45PB
Expansion Sleeve: - ST 52-3
Threaded Rod: - grade 8.8
Star washer: - stainless steel
Bolt material:
- grade 8.8 acc. DIN EN ISO 898-1 galvanised
to min.5 microns
Versions:
-HSL-I M12/0*65
-HSL-I M12/0*80
HSL-I
Concrete Hilti
Anchor
programme
HSL-I heavy duty anchor
66 Issue 2005
Basic loading data (for a single anchor): HSL-I
All data on this page applies to
x concrete: as specified in the table
x no edge distance and spacing influence
x correct setting (See setting operations page 68)
x steel failure
Characteristic resistance, R
k
[kN]: concrete # C20/25
Anchor size M12 M12
h
nom 65 80
Tensile N
Rk
26.0 34.0
Shear V
Rk
34.0 34.0
Following values according to the
Concrete Capacity Method
Design resistance, R
d
[kN]: concrete f
ck,cube
=25N/mm
2
Anchor size M12 M12
h
nom 65 80
Tensile N
Rd
17.3 22.7
Shear V
Rd
27.2 27.2
Recommended load L
rec
[kN]: concrete f
ck,cube
=25N/mm
2
Anchor size M12 M12
h
nom 65 80
Tensile N
Rec
12.4 16.2
Shear V
Rec
19.4 19.4
non-cracked concrete
Features:
- high loading capacity
- force controlled expansion
- no rotation in hole when tightening torque
Material:
Nut: - carbon steel, grade 8.8
Washer: - carbon steel acc. ASTM F 844
Anchor Body: - carbon steel, grade 8.8
Cone: - carbon steel C45PB
Expansion Sleeve: - ST 52-3
Threaded Rod: - grade 8.8
Star washer: - stainless steel
Bolt material:
- grade 8.8 acc. DIN EN ISO 898-1 galvanised
to min.5 microns
Versions:
-HSL-I M12/0*65
-HSL-I M12/0*80
HSL-I
Concrete Hilti
Anchor
programme
HSL-I heavy duty anchor
Issue 2005 67
2
Setting details
HSL-I
HSL-I M12x65 HSL-I M12x80
d
0
Nominal bit diameter
(mm) 18 18
(mm) 65 80
h
nom
embedment depth
(in.) 2.56 3.15
(mm) 80 95
h
1
Hole depth
(in.) 3.15 3.74
(mm) 130 160
h
min
;
minimum base
material thickness
(in.) 5 1/8 6 1/4
(mm) 20 20
d
h
wedge clearance hole
in plate
(in.) 0.79 0.79
(Nm) 80 80
T
inst
Installation Torque
(ft/*lb) 60 60
Wrench size (for nut)
(mm) 19 19
allen wrench size (for socket)
(mm) 6 6
Washer diameter (mm) 30 30
Installation equipment
Rotary hammer (TE1, TE2, TE5, TE6, TE6A, TE15, TE15-C, TE18-M or TE35), a blow out pump,
h
min
h
1
h
ef
h
min
HSL-I heavy duty anchor
68 Issue 2005
Drill hole. Remove dust
and debris
using
compressed
air or blow
pump.
Hammer in
anchor.
Insert Allen
wrench into the
anchor.
Turn the Allen
wrench until
resistance is
exerted.
Place fixture
and insert the
threaded rod
into the anchor.
Using the
appropriate torque
nut, apply torque
until the upper
section of torque
nut shears of.
Detailed design method - Hilti CC
TENSION
The tensile design resistance of a single anchor
is the lower of,
N
Rd,p
: concrete pull-out resistance
N
Rd,c
: concrete cone resistance
N
Rd,s
: steel resistance
N
Rd,p
: Pull-out resistance
x Pull-out failure mode not determinating
N
Rd,c
: Concrete cone resistance
RN AN B
o
c , Rd c , Rd
f f f N N
Setting operations
HSL-I heavy duty anchor
Issue 2005 69
2
N
0
Rd,c
: Design concrete cone resistance
- Concrete compressive strength. f
ck.cube(150)
= 25 N/mm
2
Anchor size M12 M12
h
nom 65 80
N
0
Rd,c
1)
17.3 22.7
1)
The design tensile resistance for concrete is calculated from the characteristic concrete tensile resistance N
0
Rk,c
divided by the partial
safety factor
Mc,N
N
0
Rd,c s
= N
0
Rk,c s
/
Mc,N
, where
Ms
= 1.5.
f
B
: Influence of concrete strength
1.0 f
B

f
AN
: Influence of anchor spacing
Anchor
spacing
Anchor size
s [mm]
M12
h
nom
=65mm
M12
h
nom
=80mm
85 0.71 0.67
90 0.73 0.69
100 0.76 0.71
110 0.78 0.73
125 0.82 0.76
140 0.86 0.79
160 0.91 0.83
180 0.96 0.88
200 0.52
220 0.96
240 1.00
f
RN
: Influence of edge distance
c
min
>c
cr,N
therefore no influence of edge distance
Minimum edge distance
Anchor size M12 M12
h
nom 65 80
c
min
100 120
N
Rd,s
: Steel design tensile resistance
Anchor size M12 M12
h
nom 65 80
N
Rd,s
1)
45.0 45.0
1)
The design tensile resistance for steel is calculated from the characteristic tensile resistance N
Rk,s
divided by the partial safety factor
Ms

N
Rd,s
= N
Rk,s
/
Ms
, where
Ms
= 1.5.
N
Rd
: System design tensile resistance
N
Rd
= lower of N
Rd,c
and N
Rd,s
Combined loading: See end of this chapter.
ef
N , A
h 6
s
5 . 0 f

-
Limits:
N , cr min
s s s s s
s
min
=85mm
s
cr;N
=3h
ef
HSL-I heavy duty anchor
70 Issue 2005
V
Rd,c
: Concrete edge design resistance
The lowest concrete edge resistance must be calculated. All nearby edges must be checked (not only the
edge in the direction of shear). Shear direction is accounted for by the factor f
,V.
V , AR V , B
o
c , Rd c , Rd
f f f V V

V
0
Rd,c
: Concrete edge design resistance
- Concrete compressive strength f
ck,cube(150)
= 25 N/mm
2
- at a minimum edge distance
min
c
Anchor size M12 M12
h
nom 65 80
V
0
Rd,c
1)
10.2 14.3
c
min
100 125
1)
The design value for the ultimate state in concrete shear is calculated from the characteristic concrete shear resistance V
0
Rk,c
divided by

Mc,V
V
0
Rd,c
= V
0
Rk,c
/
Mc,V
; where
Mc,V
= 1.5.
f
B
: Influence of concrete strength
1.0 f
B

f
,V
: Influence of shear load direction
Angle []
f
.V
0 to 55 1
60 1.1
70 1.2
80 1.5
90 to 180 2
Formulae:
1 f
V ,

sin 5 . 0 cos
1
f
V ,
2 f
V ,

for 0 s s 55
for 55 < s 90
for 90 < s 180
f
AR,V
: Influence of spacing and edge
distance
Formula for single anchor fastening
influenced only by edge
min min
V , AR
c
c
c
c
f
Formula for two-anchor fastening valid for s < 3c
min min
V , AR
c
c
c 6
s c 3
f
-

Results for single anchor and two anchor fastening tabled below.
V ... applied shear force

Detailed design method Hilti CC


SHEAR
The design shear resistance of a single
anchor is the lower of:
V
Rd,c
: concrete edge resistance
V
Rd,s
: steel resistance
V
c
s
rec,c/s
c
>
1
.
5
c
2
c
>
1
.
5
c
2
h
>
1
.
5
c
Note: If the conditions regarding h and c
2
are not met.
consult your Hilti technical advisory service.
(The Hilti CC-Method is a simplified Version of ETAG Annex C)
HSL-I heavy duty anchor
Issue 2005 71
f
AR.V
c/c
min
1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0
Single anchor with
edge influence
1.00 1.31 1.66 2.02 2.41 2.83 3.26 3.72 4.19 4.69 5.20 5.72 6.27 6.83 7.41 8.00
s/c
min
1.0 0.67 0.84 1.03 1.22 1.43 1.65 1.88 2.12 2.36 2.62 2.89 3.16 3.44 3.73 4.03 4.33
1.5 0.75 0.93 1.12 1.33 1.54 1.77 2.00 2.25 2.50 2.76 3.03 3.31 3.60 3.89 4.19 4.50
2.0 0.83 1.02 1.22 1.43 1.65 1.89 2.13 2.38 2.63 2.90 3.18 3.46 3.75 4.05 4.35 4.67
2.5 0.92 1.11 1.32 1.54 1.77 2.00 2.25 2.50 2.77 3.04 3.32 3.61 3.90 4.21 4.52 4.83
3.0 1.00 1.20 1.42 1.64 1.88 2.12 2.37 2.63 2.90 3.18 3.46 3.76 4.06 4.36 4.68 5.00
3.5 1.30 1.52 1.75 1.99 2.24 2.50 2.76 3.04 3.32 3.61 3.91 4.21 4.52 4.84 5.17
4.0 1.62 1.86 2.10 2.36 2.62 2.89 3.17 3.46 3.75 4.05 4.36 4.68 5.00 5.33
4.5 1.96 2.21 2.47 2.74 3.02 3.31 3.60 3.90 4.20 4.52 4.84 5.17 5.50
5.0 2.33 2.59 2.87 3.15 3.44 3.74 4.04 4.35 4.67 5.00 5.33 5.67
5.5 2.71 2.99 3.28 3.57 3.88 4.19 4.50 4.82 5.15 5.49 5.83
6.0 2.83 3.11 3.41 3.71 4.02 4.33 4.65 4.98 5.31 5.65 6.00
6.5 3.24 3.54 3.84 4.16 4.47 4.80 5.13 5.47 5.82 6.17
7.0 3.67 3.98 4.29 4.62 4.95 5.29 5.63 5.98 6.33
7.5 4.11 4.43 4.76 5.10 5.44 5.79 6.14 6.50
8.0 4.57 4.91 5.25 5.59 5.95 6.30 6.67
8.5 5.05 5.40 5.75 6.10 6.47 6.83
9.0 5.20 5.55 5.90 6.26 6.63 7.00
9.5 5.69 6.05 6.42 6.79 7.17
10.0 6.21 6.58 6.95 7.33
10.5 6.74 7.12 7.50
11.0 7.28 7.67
11.5 7.83
12.0 8.00
V
Rd,s
1)
: Steel design shear resistance
Anchor size M12 M12
h
nom 65 80
V
Rd,s
1)
27.2 27.2
1)
The design shear resistance is calculated from V
Rd,s
= V
Rk,s
/
Ms,V
. The partial safety factor
Ms,V
is 1.25.
V
Rd
: System design shear resistance
V
Rd
: System design shear resistance
V
Rd
= lower of V
Rd,c
and V
Rd,s
Combined loading
( ) ( )
1.0
V
V
N
N
1,5
Rd
Sd
1,5
Rd
Sd
s
|
|
.
|

\
|
-
|
|
.
|

\
|
These results are for a two-.
Anchor fastening.
For fastening made with more
than 2 anchors, use the
general formulae for n
anchors the page before.
General formula for n anchors (edge distance plus n-1 spacing)
only valid where s
1
to s
n-1
are all < 3c and c
2
> 1.5c
min min
1 n 2 1
V , AR
c
c
nc 3
s ... s s c 3
f
- - - -

-
c
c
s
s
s
2,2
1
2
3
n-1
s
c
2,1
h >1,5 c
Note: It is assumed that only the row of anchors closest to
the free concrete edge carries the centric shear load
2
HVU adhesive with HAS-R/-HCR rod underwater
254 Issue 2005
Features
- underwater fastening
- no loss of holding power from curing under water
- for permanently damp or wet fastenings /
applications
- suitable for sea water
- exerts very low expansion forces
- small edge distances and spacing
- externally tested and approved
Material
HAS-R: - stainless steel; A4-70; 1.4401, 1.4404, 1.4571
HAS-HCR: - stainless steel; 1.4529
HVU Capsule
- urethane methacrylate resin, styrene free, hardener,
quartz sand or corundum, foil tube
Mortar: - Hilti HIT HY 20, standard size 330 ml
Dispenser: - MD 2000
Setting details
Anchor size
Setting detail
M 8 M 10 M 12 M 16 M 20 M 24
Foil capsule HVU M 8 X 80 M 10 x 90 M 12 x 110 M 16 x 125 M 20 x 170 M 24 x 210
d
0
[mm] Drill bit diameter 10 12 14 18 24 28
h
1
[mm] Hole depth 80 90 110 125 170 210
t
fix
1)
[mm] Max. fixture thickness 14 21 28 38 48 54
d
f
[mm] Max. clearance hole 11 13 15 19 26 29
l [mm] Anchor length 110 130 160 190 240 290
T
inst
[Nm] Tightening torque 18 35 60 120 260 450
S
w
[mm] Width across flats 13 17 19 24 30 36
h
min
[mm]
Min. thickness of
basematerial
100 120 140 170 220 270
Drill bit and drilling machine Suitable commercially available tools must be used under water
Pre-injection with Hilti HY 20
Trigger pulls with MD 2000 / P 3000 UW/F
1 1 2 3 5 8
1)
The values for the total rod length and the maximum fixture thickness are only valid for the HAS anchor rods given in this
table. If other HAS rods are used, these values will change. (Example: HAS M12 x 260/128; l = 260 mm and t
fix
= 128 mm)
Setting temperature:(water temperature) Curing time until full loading:
-5 C to 0 C 10 hours
0 C to 10 C 2 hours
10 C to 20 C 1 hours
20 C and above 30 minutes
HCR
highMo
Concrete
High corrosion
resistance
Small edge
distance/
spacing
A4
316
Corrosion
resistance
d
0
d
f
h
h
t
fix
min
HVU adhesive with HAS-R/-HCR rod underwater
Issue 2005 255
3
Setting operations

Drill hole. Clean hole.
Inject HIT-HY 20 (observe
number of trigger pulls).
Insert HVU capsule.

HIT-HY 20 adhesive mortar
displaces water in hole.
Insert HAS-R (HAS-HCR)
threaded rod.
Remove setting tool (after t
rel
).
Set threaded rod with part
fastened.
Design: See HVU adhesive with HAS rod
(no additional load reduction applicable)
HVU adhesive with HIS-RN sleeve underwater
256 Issue 2005
Design: See HVU adhesive with HIS-N/HIS-RN sleeve (no load additional reduction
applicable)
HIT-HY 20 adhesive mortar
displaces water in hole.
Insert HIS-RN threaded rod. Remove setting tool (after t
rel
).
Set threaded rod with part
fastened.
Drill hole. Clean hole.
Inject HIT-HY 20 (observe
number of trigger pulls).
Insert HVU capsule.

Setting operations

Setting details
Anchor size
Setting detail
M 8 M 10 M 12 M 16 M 20
Capsule HVU M 10 x 90 M 12 x 110 M 16 x 125 M 20 x 170 M 24 x 210
d
0
[mm] Drill bit diameter 14 18 22 28 32
h
1
[mm] Hole depth 90 110 125 170 205
T
inst
[Nm] Tightening torque 12 23 40 70 130
h
min
[mm]
Min. thickness of
basematerial
120 150 170 230 280
h
s
[mm] Thread engagement min. 8 10 12 16 20
max. 20 25 30 40 50
Drill bit and drilling machine Suitable commercially available tools must be used under water
Pre-injection with Hilti HY 20
Trigger pulls with MD 2000
1 1 2 3 5
Setting temperature: -5 C to 0 C Curing time until full 10 hours
(water temperature) 0 C to 10 C loading: 2 hours
10 C to 20 C 1 hours
20 C and above 30 minutes
Features
- underwater fastening
- no loss of holding power from curing under water
- for permanently damp or wet fastenings /
applications
- suitable for sea water
- exerts very low expansion farces
- small edge distances spacing
- fastenings flush with work surface
Material
HIS-RN: - stainless steel, A4-70: 1.4401
HVU Capsule
- urethane methacrylate resin, styrene free, hardener,
quartz sand or corundum, foil tube
Mortar: - Hilti HIT HY 20, standard size 330 ml
Dispenser: - MD 2000
A4
316
Concrete
Corrosion
resistance
Small edge
distance/ spacing
h
s
d
f
d
0
min
h
1
h
nom
h
HVU adhesive with rebar
218 Issue 2005
Features:
- complete ready-to-use rebar fastening
- foil capsule vs. glass
- no expansion force in base material
- high loading capacity
- small edge distance and spacing
Material:
Rebar:
- Type BSt 500 according to DIN 488 (See also
Euronorm 82-79). For differing rebars, consult
your Hilti advisory service.
HVU Capsule:
- urethane methacrylate resin, styrene free,
hardener, quartz sand or corundum, foil tube
HVU capsule
Rebar section
Concrete
Small edge
distance /
spacing/
Fire resistance
Hilti Anchor
programme
Basic loading data (for a single anchor): HVU capsule with rebar section
All data on this page applies to For detailed design method, see pages 220 224.
- concrete: See table below.
- correct setting (See setting operations page 219)
- no edge distance and spacing influence
- steel failure
Mean ultimate resistance, R
u,m
[kN]: concrete = C20/25
Rebar diameter
(mm)
10 12 14 16 20 25 28 32 36
Tensile, N
Ru,m
33.4 66.0 98.9 99.9 176.8 216.3 378.9 449.1 528.7
Shear, V
Ru,m
28.1 40.4 55.0 71.8 112.3 175.0 219.2 286.3 384.5
Characteristic resistance, R
k
[kN]: concrete = C20/25
Rebar diameter
(mm)
10 12 14 16 20 25 28 32 36
Tensile, N
Rk
15.9 50.1 69.7 68.4 128.1 128.0 259.1 312.1 372.3
Shear, V
Rk
26.0 37.4 50.9 66.5 104.0 162.0 203.0 265.1 356.0
Following values according to the
Concrete Capacity Method
Design resistance, R
d
[kN]: concrete, f
ck,cube
= 25 N/mm
2
Rebar diameter
(mm)
10 12 14 16 20 25 28 32 36
Tensile, N
Rd
15.0 23.0 31.4 34.9 59.3 91.6 115.4 136.1 158.3
Shear, V
Rd
17.3 24.9 33.9 44.3 69.3 108.0 135.3 176.7 237.3
Recommended load, L
rec
[kN]: concrete, f
ck,cube
= 25 N/mm
2
Rebar diameter
(mm)
10 12 14 16 20 25 28 32 36
Tensile, N
Rec
10.7 16.4 22.4 24.9 42.3 65.4 82.4 97.2 113.1
Shear, V
Rec
12.4 17.8 24.2 31.6 49.5 77.1 96.6 126.2 169.5
non-cracked concrete
HVU adhesive with rebar
Issue 2005 219
3
h
1
h
d
0
0

d
/
Setting details
Rebar size, C [mm] 10 12 14 16 20 25 28 32 36
Capsule HVU... M10x90 M12x110 M16x125 M16x125 M20x170 M24x210 M30x270 M33x330 M39x360
d
0
[mm] Drill bit diameter 12 16 18 20 25 30 35 40 42
h
1
[mm] Hole depth 90 110 125 125 170 210 270 300 360
h
min
[mm]
Min. thickness of base
material
120 140 170 170 220 270 340 380 460
TE-CX- 12/22 15/27 - - - - - - -
Drill bit
TE-T- - - 18/32 20/32 25/52 30/57 - - -
Recommended diamond drilling machine DD 80 E // DD 160 E
Temperature when setting:
Min. time to wait before
removing SCREWED-ON
setting tool,
t
rel
Curing time before anchor
can be fully loaded,
t
cure
20C and above
10C to 20C
0C to 10C
-5C to 0C
8 min.
20 min.
30 min.
1 hour
20 min.
30 min.
1 hour
5 hours
less than -5C Contact your Hilti advisory service.
Installation equipment
Rotary hammer (TE5, TE6, TE6A, TE15, TE15-C, TE18-M, TE 35, TE 55 or TE 76) or a diamond drilling
machine, a drill bit and a blow-out pump. Pre-cut thread on rebar, nut welded on rebar and rebar adapter.
Setting operations
1 2 3
HVU
5
REBAR
4
Drill hole.
Blow out dust and
fragments.
Insert HVU capsule. Drive in the rebar section.
5
t
rel
6
t
cure
Allow gel time to
pass.
Wait for curing.
min
h
nom
HVU adhesive with rebar
220 Issue 2005
Anchor geometry and mechanical properties
Rebar diameter [mm] 10 12 14 16 20 25 28 32 36
HVU capsule M10x90 M12x110 M16x125 M16x125 M20x170 M24x210 M30x270 M33x330 M39x360
lp [mm] HVU capsule length 110 127 140 140 170 200 260 290 320
d [mm] Nominal rebar diameter 10,7 13,1 17,1 17,1 22 25,7 31,5 31,5 35
Rebar section
d [mm] Nominal rebar diameter 10 12 14 16 20 25 28 32 36
A
s
[mm] Stressed cross-section 78,5 113,1 153,9 201,1 314,2 490,9 615,8 804,2 1017,9
f
uk
[N/mm] Nominal tensile strength 550
f
yk
[N/mm] Yield strength 500
Detailed design method - Hilti CC
Caution: In view of the high loads transferable with the HVU, it must be verified by the user that the load acting
on the concrete structure, including the loads introduced by the anchor fastening, do not cause failure, e.g.
cracking, of the concrete structure.
TENSION
The design tensile resistance of a single anchor
is the lower of
N
Rd,c
: concrete cone/pull-out resistance
N
Rd,s
: steel resistance
N
Rd,c
: Concrete cone/pull-out resistance
N , R N , A N , B T
o
c , Rd c , Rd
f f f f N N
N
0
Rd,c
: Concrete cone/pull-out design resistance
- Concrete compressive strength, f
ck,cube(150)
= 25 N/mm
2
Rebar diameter [mm] 10 12 14 16 20 25 28 32 36
N
o
Rd,c
1)
[kN] 15.0 23.0 31.4 34.9 59.3 91.6 115.4 136.1 158.3
h
nom
[mm] Nominal anchorage depth 90 110 125 125 170 210 270 300 360
1)
The design tensile resistance is calculated from the characteristic tensile resistance, N
o
Rk,c
, by N
o
Rd,c
= N
o
Rk,c
/
Mc,N
, where the partial
safety factor,
Mc,N
, is 1.8.
(The Hilti CC method is a simplified version of ETAG Annex C.)
anchorage depth addtional length
according to application
d
d
p
l
p
HVU M..
HVU M.. HVU M..
N
c
s
h
rec,c/s
HVU adhesive with rebar
Issue 2005 221
3
f
T
: Influence of anchorage depth
nom
act
T
h
h
f Limits to actual anchorage depth h
act
: h
nom
s h
act
s 2.0h
nom
f
B,N
: Influence of concrete strength
Concrete strength
designation
(ENV 206)
Cylinder compressive
strength,
f
ck,cyl
[N/mm]
Cube compressive
strength,
f
ck,cube
[N/mm]
f
B,N
C20/25 20 25 1
C25/30 25 30 1,02
C30/37 30 37 1,06
C35/45 35 45 1,09
C40/50 40 50 1,12
C45/55 45 55 1,14
C50/60 50 60 1,16
Concrete cylinder:
Height 30cm, 15cm
diameter
Concrete cube:
side length 15 cm
Concrete test specimen geometry
|
|
.
|

\
| -
-
5 . 212
25 f
1 f
cube , ck
N , B
Limits:
25 N/mm s f
ck,cube(150)
s 60 N/mm
f
A,N
: Influence of rebar spacing
Rebar diameter (mm) Anchor
spacing,
s [mm] 10 12 14 16 20 25 28 32 36
45 0,63
50 0,64
55 0,65 0,63
60 0,67 0,64
65 0,68 0,65 0,63 0,63
70 0,69 0,66 0,64 0,64
80 0,72 0,68 0,66 0,66
90 0,75 0,70 0,68 0,68 0,63
100 0,78 0,73 0,70 0,70 0,65
120 0,83 0,77 0,74 0,74 0,68 0,64
140 0,89 0,82 0,78 0,78 0,71 0,67 0,63
160 0,94 0,86 0,82 0,82 0,74 0,69 0,65 0,63
180 1,00 0,91 0,86 0,86 0,76 0,71 0,67 0,65 0,63
200 0,95 0,90 0,90 0,79 0,74 0,69 0,67 0,64
220 1,00 0,94 0,94 0,82 0,76 0,70 0,68 0,65
250 1,00 1,00 0,87 0,80 0,73 0,71 0,67
280 0,91 0,83 0,76 0,73 0,69
310 0,96 0,87 0,79 0,76 0,72
340 1,00 0,90 0,81 0,78 0,74
390 0,96 0,86 0,83 0,77
420 1,00 0,89 0,85 0,79
450 0,92 0,88 0,81
480 0,94 0,90 0,83
540 1,00 0,95 0,88
600 1,00 0,92
660 0,96
720 1,00
f
R,N
: Influence of edge distance
Rebar diameter (mm) Edge
distance,
c [mm] 10 12 14 16 20 25 28 32 36
45 0,64
50 0,68
55 0,72 0,64
60 0,76 0,67
65 0,80 0,71 0,65 0,65
70 0,84 0,74 0,68 0,68
80 0,92 0,80 0,74 0,74
90 1,00 0,87 0,80 0,80 0,66
100 0,93 0,86 0,86 0,70
110 1,00 0,91 0,91 0,75 0,66
120 0,97 0,97 0,79 0,69
140 1,00 1,00 0,87 0,76 0,65
160 0,96 0,83 0,71 0,66
180 1,00 0,90 0,76 0,71 0,64
210 1,00 0,84 0,78 0,70
240 0,92 0,86 0,76
270 1,00 0,93 0,82
300 1,00 0,88
330 0,94
360 1,00
nom
N , A
h 4
s
5 , 0 f -
Limits: s
min
s s s s
cr,N
s
min
= 0,5h
nom
s
cr,N
= 2,0h
nom
nom
N , R
h
c
72 , 0 28 , 0 f -
Limits: c
min
s c s c
cr,N
c
min
= 0,5h
nom
c
cr,N
= 1,0h
nom
Note: If more than 3
edges are smaller than
c
cr,N
, consult your Hilti
technical advisory
service.
HVU adhesive with rebar
222 Issue 2005
N
Rd,s
1)
: Steel design tensile resistance
Rebar diameter [mm] 10 12 14 16 20 25 28 32 36
N
Rd,s
1)
[kN] rebar section 32.7 47.1 64.1 83.8 130.9 204.5 256.6 335.1 424.1
1)
The design tensile resistance is calculated from the characteristic tensile resistance, N
Rk,s
, by
N
Rd,s
= A
s
f
uk
/
Ms,N
, where the partial safety factor,
Ms,N
, for rebar sections of type BSt 500 is 1.32.
N
Rd
: System design tensile resistance
N
Rd
= lower of N
Rd,c
and N
Rd,s
Combined loading: Only if tensile load and shear load applied (See page 31 and section 4 Examples").
Detailed design method Hilti CC
SHEAR
The design shear resistance of a single
anchor is the lower of
V
Rd,c
: concrete edge resistance
V
Rd,s
: steel resistance
V
Rd,c
: Concrete edge design resistance
The lowest concrete edge resistance must be calculated. All near edges must be checked (not only the edge in
the direction of shear). The direction of shear is accounted for by the factor f
,V
.
V , V , AR V , B
0
c , Rd c , Rd
f f f V V


V
0
Rd,c
: Concrete edge design resistance
- concrete compressive strength, f
ck,cube(150)
= 25 N/mm
2
- at a minimum edge distance
min
c
Rebar diameter [mm] 10 12 14 16 20 25 28 32 36
V
o
Rd,c
1)
[kN] 3.6 5.0 7.1 7.3 12.5 18.8 30.2 37.7 52.1
c
min
[mm] Min. edge distance 45 55 65 65 85 105 135 150 180
1)
The shear design resistance is calculated from the characteristic shear resistance, V
o
Rk,c
, by V
o
Rd,c
= V
o
Rk,c
/
Mc,V
, where the partial safety
factor,
Mc,V
, is 1.5.
(The Hilti CC method is a simplified version of ETAG Annex C.)
V
c
s
rec,c/s
c
>
1
.5
c
2
c
>
1
.
5
c
2
h
>
1
.5
c
HVU adhesive with rebar
Issue 2005 223
3
f
B,V
: Influence of concrete strength
Concrete strength
designation
(ENV 206)
Cylinder compressive
strength,
f
ck,cyl
[N/mm]
Cube compressive
strength,
f
ck,cube
[N/mm]
f
B,V
C20/25 20 25 1
C25/30 25 30 1.1
C30/37 30 37 1.22
C35/45 35 45 1.34
C40/50 40 50 1.41
C45/55 45 55 1.48
C50/60 50 60 1.55
Concrete cylinder:
Height 30cm, 15cm
diameter
Concrete cube:
side length 15 cm
Concrete test specimen geometry
f
AR,V
: Influence of edge distance and spacing
c/c
min
f
AR,V
1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0
Single anchor with
edge influence,
1.00 1.31 1.66 2.02 2.41 2.83 3.26 3.72 4.19 4.69 5.20 5.72 6.27 6.83 7.41 8.00
s/c
min
1.0 0.67 0.84 1.03 1.22 1.43 1.65 1.88 2.12 2.36 2.62 2.89 3.16 3.44 3.73 4.03 4.33
1.5 0.75 0.93 1.12 1.33 1.54 1.77 2.00 2.25 2.50 2.76 3.03 3.31 3.60 3.89 4.19 4.50
2.0 0.83 1.02 1.22 1.43 1.65 1.89 2.13 2.38 2.63 2.90 3.18 3.46 3.75 4.05 4.35 4.67
2.5 0.92 1.11 1.32 1.54 1.77 2.00 2.25 2.50 2.77 3.04 3.32 3.61 3.90 4.21 4.52 4.83
3.0 1.00 1.20 1.42 1.64 1.88 2.12 2.37 2.63 2.90 3.18 3.46 3.76 4.06 4.36 4.68 5.00
3.5 1.30 1.52 1.75 1.99 2.24 2.50 2.76 3.04 3.32 3.61 3.91 4.21 4.52 4.84 5.17
4.0 1.62 1.86 2.10 2.36 2.62 2.89 3.17 3.46 3.75 4.05 4.36 4.68 5.00 5.33
4.5 1.96 2.21 2.47 2.74 3.02 3.31 3.60 3.90 4.20 4.52 4.84 5.17 5.50
5.0 2.33 2.59 2.87 3.15 3.44 3.74 4.04 4.35 4.67 5.00 5.33 5.67
5.5 2.71 2.99 3.28 3.57 3.88 4.19 4.50 4.82 5.15 5.49 5.83
6.0 2.83 3.11 3.41 3.71 4.02 4.33 4.65 4.98 5.31 5.65 6.00
6.5 3.24 3.54 3.84 4.16 4.47 4.80 5.13 5.47 5.82 6.17
7.0 3.67 3.98 4.29 4.62 4.95 5.29 5.63 5.98 6.33
7.5 4.11 4.43 4.76 5.10 5.44 5.79 6.14 6.50
8.0 4.57 4.91 5.25 5.59 5.95 6.30 6.67
8.5 5.05 5.40 5.75 6.10 6.47 6.83
9.0 5.20 5.55 5.90 6.26 6.63 7.00
9.5 5.69 6.05 6.42 6.79 7.17
10.0 6.21 6.58 6.95 7.33
10.5 6.74 7.12 7.50
11.0 7.28 7.67
11.5 7.83
12.0 8.00
25
f
f
cube , ck
V , B

Limits:
25 N/mm
2
s f
ck,cube(150)
s 60 N/mm
2
These results are for a two-
anchor fastening.
For fastenings with more than
two anchors, use the general
formulae for n anchors.
HVU adhesive with rebar
224 Issue 2005
c
c
s
s
s
2,2
1
2
3
n-1
s
c
2,1
h >1,5 c
Note: It is assumed that only the row of anchors closest to
the free concrete edge carries the centric shear load.
f
AR,V
: Influence of edge distance and spacing
Formula for single-anchor fastening influenced
only by edge
min min
V , AR
c
c
c
c
f
Formula for two-anchor fastening (edge plus
1 spacing) only valid for s < 3c
min min
V , AR
c
c
c 6
s c 3
f

General formula for n-anchor fastening (edge plus n-1 spacing)


only valid where s
n
and s
n-1
are each < 3c and c
2
> 1.5c
min min
1 n 2 1
V , AR
c
c
c n 3
s ... s s c 3
f

- - - -

-
f
,V
: Influence of loading direction
Angle, [] f
,V
0 to 55 1
60 1.1
70 1.2
80 1.5
90 to 180 2
V
Rd,s
: Steel design shear resistance
Rebar diameter [mm] 10 12 14 16 20 25 28 32 36
V
Rd,s
1)
[kN] 17,3 24,9 33,9 44,3 69,3 108,0 135,3 176,7 224,0
1)
The design shear resistance is calculated from V
Rd,s
= (0,6A
s
f
uk
)/
Ms,V
. The partial safety factor,
Ms,V
, for rebar sections of type BSt 500 is
1.5.
V
Rd
: System design shear resistance
V
Rd
= lower of V
Rd,c
and V
Rd,s
Combined loading: Only if tensile load and shear load applied (See page 31 and section 4 Examples).
1 f
V ,

sin 5 , 0 cos
1
f
V ,
-

2 f
V ,

for 0 s s 55
for 55 < s 90
for 90 < s 180
Formulae:
V ... applied shear force

results
tabulated
below
HVU adhesive with HAS rod
200 Issue 2005
Concrete Capacity Method
Design resistance, R
d
[kN]: concrete, f
ck,cube
= 25 N/mm
2
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Tensile, N
Rd
10.9 16.6 23.8 34.7 62.9 90.6 110.9 145.6 171.0 203.3 232.9
Shear, V
Rd
7.9 12.6 18.3 34.6 54.0 77.8 164.0 199.3 248.4 291.5 350.6
Recommended load, L
rec
[kN]: concrete, f
ck,cube
= 25 N/mm
2
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Tensile, N
Rec
7.8 11.8 17.0 24.8 44.9 64.7 79.2 104.0 122.1 145.2 166.4
Shear, V
Rec
5.6 9.0 13.1 24.7 38.6 55.6 117.1 142.4 177.4 208.2 250.4
Features:
- foil capsule vs. glass
- flexible for inserting into crooked / irregular holes
- pre-setting / through-setting
- specials lengths available on request
- test reports: fire, dynamic (fatigue, shock, seismic),
water tightness
Material:
HVU:
- urethane methacrylate resin styrene free, hardener,
quartz sand or corundum, foil tube
HAS, HAS-E:
- grade 5.8 and 8.8, ISO 898 T1, galvanised to min.
5 microns
HAS-R / -ER: - stainless steel; A4-70; 1.4401, 1.4404, 1.4571
HAS-HCR: - stainless steel; 1.4529
HVU capsule
HAS, HAS-R, HAS-HCR
HAS-E, HAS-E-R
Concrete
Small edge
distance /
spacing
Fatigue
Seismic
A4
316
HCR
highMo
Corrosion
resistance
High
corrosion
resistance
Fire resistance
Hilti Anchor
programme
Basic loading data (for a single anchor): HVU capsule with HAS, HAS-E
All data on this page applies to For detailed design method, see pages 204 208.
- concrete: See table below.
- correct setting (See setting operations page 203)
- no edge distance and spacing influence
- steel failure: steel grade 5.8 for M8 M24 sizes and steel grade 8.8 for M27 M39
Mean ultimate resistance, R
u,m
[kN]: concrete = C20/25
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Tensile, N
Ru,m
17.7 28.2 41.1 77.9 121.7 175.2 320.1 305.1 498.6 534.0 621.6
Shear, V
Ru,m
10.7 17.0 24.7 46.7 72.9 105.0 221.4 269.1 335.3 393.5 473.3
Characteristic resistance, R
k
[kN]: concrete = C20/25
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Tensile, N
Rk
16.4 26.1 38.1 72.2 112.7 162.0 182.4 228.0 440.9 494.0 503.2
Shear, V
Rk
9.9 15.8 22.9 43.2 67.5 97.3 205.0 249.1 310.5 364.4 438.3
Following values according to the
non-cracked concrete
HVU adhesive with HAS rod
Issue 2005 201
3
Basic loading data (for a single anchor): HVU capsule with HAS-R, HAS-E-R, HAS-HCR
All data on this section applies to For detailed design method, see pages 204 208.
- concrete: See table below.
- correct setting (See setting operations page 203)
- no edge distance and spacing influence
- steel failure: steel grade A4-70 for M8 M24; for A4 grade, f
uk
changes for the sizes M27 to M39 from
700 N/mm
2
to 500 N/mm
2
.
Mean ultimate resistance, R
u,m
[kN]: concrete = C20/25
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Tensile, N
Ru,m
24.8 39.6 57.8 109.1 170.3 244.4 230.7 280.2 349.4 410.1 493.0
Shear, V
Ru,m
14.8 23.8 34.5 65.4 102.1 146.9 138.5 168.3 209.7 246.0 295.9
Characteristic resistance, R
k
[kN]: concrete = C20/25
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Tensile, N
Rk
23.0 36.7 53.5 101.0 157.6 226.3 213.6 259.4 323.5 379.7 456.5
Shear, V
Rk
13.7 22.0 32.0 60.5 94.5 136.0 128.2 155.8 194.2 227.8 274.0
Following values according to the
Concrete Capacity Method
Design resistance, R
d
[kN]: concrete, f
ck,cube
= 25 N/mm
2
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Tensile, N
Rd
12.3 16.6 23.8 34.7 62.9 90.6 89.0 108.1 134.8 158.2 190.2
Shear, V
Rd
8.8 14.1 20.5 38.8 60.6 87.2 64.1 77.9 97.1 113.9 137.0
Recommended load, L
rec
[kN]: concrete, f
ck,cube
= 25 N/mm
2
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Tensile, N
Rec
8.8 11.8 17.0 24.8 44.9 64.7 63.6 77.2 96.3 113.0 135.9
Shear, V
Rec
6.3 10.1 14.6 27.7 43.3 62.3 45.8 55.6 69.4 81.3 97.9
non-cracked concrete
HVU adhesive with HAS rod
202 Issue 2005
d
0
d
f
h
1
h
t
fix
min
Setting details
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Foil capsule HVU M8x80 M10x90 M12x110 M16x125 M20x170 M24x210 M27x240 M30x270 M33x300 M36x330 M39x360
Anchor rod
1)
HAS /-E/-R/-ER/-HCR
M8x80/
14
M10x90/
21
M12x110/
28
M16x125/
38
M20x170/
48
M24x210/
54
M27x240/
60
M30x270/
70
M33x300/
80
M36x330/
90
M39x360/
100
d
0
Drill bit diameter
[mm]
10 12 14 18 24 28 30 35 37 40 42
h
1
=h
nom
Hole depth =
Embedment depth
[mm] 80 90 110 125 170 210 240 270 300 330 360
h (min)
Min. thickness
of base material
[mm] 110 120 140 170 220 270 300 340 380 410 450
t
fix
(max)
Max. fixture
thickness
[mm] 14 21 28 38 48 54 60 70 80 90 100
d
f
Clearance
hole
rec. [mm]
max. [mm]
9
11
12
13
14
15
18
19
22
25
26
29
30
31
33
36
36
38
39
41
42
43
T
inst
Tightening torque [Nm] 15 30 50 100 160 240 270 300 1200 1500 1800
TE-CX- 10/22 12/22 14/22 - - - - - - - -
Drill bit
TE-T- - - - 18/32 24/32 28/52 30/57 - - - -
Rec. diamond drilling machine DD EC-1 DD 100 // DD 160 E
1)
The values for the maximum fixture thickness are only valid for the HAS anchor rods given in this table.
If other HAS rods are used, these values will change. (Example: HAS M12x110/128; t
fix
= 128 mm)
Temperature
1)
when setting:
Min. time to wait before
removing SCREWED-ON
setting tool,
t
rel
Curing timebefore anchor can
be fully loaded,
t
cure
20C and above
10C to 20C
0C to 10C
-5C to 0C
8 min.
20 min.
30 min.
60 min.
20 min.
30 min.
60 min.
5 hours
1)
If the temperature is less than 5C, contact your Hilti technical service.
Installation equipment
Rotary hammer (TE1, TE 2, TE5, TE6, TE6A, TE15, TE15-C, TE18-M, TE 35, TE 55 or TE 76) or a diamond
drilling machine, a drill bit, a TE-C HEX, TE-C-E TE-Y-E setting tool and a blow-out pump.
HVU adhesive with HAS rod
Issue 2005 203
3
Setting operations
1 2 3
HVU
5
HAS
4
Drill hole.
Blow out dust and
fragments.
Insert HVU capsule. Drive in anchor.
5
t
rel
6
t
cure
7
T
inst
Allow gel time to pass. Wait for curing.
Apply tightening
torque.
Anchor geometry and mechanical properties
d
p
l
p l
d
w
S
w
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Foil capsule HVU
M8x80 M10x90 M12x110 M16x125 M20x170 M24x210 M27x240 M30x270 M33x300 M36x330 M39x360
l
p
[mm] HVU capsule length 110 110 127 140 170 200 225 260 290 320 350
d
p
[mm] HVU capsule diameter 9.3 10.7 13.1 17.1 22.0 25.7 26.8 31.5 31.5 32.0 35.0
Anchor rod HAS
M8x80/
14
M10x90/
21
M12x110/
28
M16x125/
38
M20x170/
48
M24x210/
54
M27x240/
60
M30x270/
70
M33x300/
80
M36x330/
90
M39x360/
100
l [mm] Anchor length 110 130 160 190 240 290 340 380 420 460 510
A
s
[mm
2
] Stressed cross-section 32.8 52.3 76.2 144 225 324 427 519 647 759 913
HAS 5.8 500 500 500 500 500 500 - - - - -
HAS 8.8 - - - - - - 800 800 800 800 800
HAS-R
f
uk
[N/mm
2
] Nominal tensile
strength
-HCR
700 700 700 700 700 700 500 500 500 500 500
HAS 5.8 400 400 400 400 400 400 - - - - -
HAS 8.8 - - - - - - 640 640 640 640 640
HAS-R
f
yk
[N/mm
2
] Yield strength
-HCR
450 450 450 450 450 450 250 250 250 250 250
W [mm
3
] Moment of resistance 26.5 53.3 93.9 244 477 824 1245 1668 2322 2951 3860
HAS 5.8 12.7 25.6 45.1 117.1 228.8 395.3 - - - - -
HAS 8.8 - - - - - - 956.1 1280.8 1783.5 2266.5 2987.8
HAS-R
M
Rd,s
[Nm]
Design bending
resistance
1)
-HCR
14.3 28.7 50.6 131.4 256.7 443.5 478.8 641.5 893.0 1134.9 1484.5
S
w
[mm] Width across flats 13 17 19 24 30 36 41 46 50 55 59
d
w
[mm] Washer diameter 16 20 24 30 37 44 50 56 60 66 72
1)
The design bending resistance of the anchor rod is calculated from M
Rd,s
= (1.2 W f
uk
)/
Ms,b
, where the partial safety factor,
Ms,b
, for
grade 5.8 and 8.8 rods is 1.25 and for 1.56 for A4-70 and HCR. The final safety check is then M
Sk

F
s M
Rd,s
d
p
l
p
HVU M.. HVU M.. HVU M..
HVU adhesive with HAS rod
204 Issue 2005
Detailed design method - Hilti CC
Caution: In view of the high loads transferable with HVU, it must be verified by the user that the load acting on
the concrete structure, including the loads introduced by the anchor fastening, do not cause failure, e.g.
cracking, of the concrete structure.
TENSION
The design tensile resistance of a single anchor
is the lower of
N
Rd,c
: concrete cone/pull-out resistance
N
Rd,s
: steel resistance
N
Rd,c
: Concrete cone/pull-out resistance
N , R N , A T N , B
o
c , Rd c , Rd
f f f f N N
N
0
Rd,c
: Concrete cone/pull-out design resistance
- Concrete compressive strength, f
ck,cube(150)
= 25 N/mm
2
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
N
0
Rd,c
1)
[kN]
12.4 16.6 23.8 34.7 62.9 90.6 110.9 145.6 171.0 203.3 232.9
h
nom
[mm] Nominal anchorage depth 80 90 110 125 170 210 240 270 300 330 360
1)
The design tensile resistance is calculated from the characteristic tensile resistance, N
Rk,c
, by N
Rd,c
= N
Rk,c
/
Mc,N
, where the
partial safety,
Mc,N
, factor is 1.8.
f
B,N
: Influence of concrete strength
Designation of
grade of
concrete
(ENV 206)
Cylinder
compressive
strength,
f
ck,cyl
[N/mm]
Cube compressive
strength,
f
ck,cube
[N/mm]
f
B,N
C16/20 16 20 0.94
C20/25 20 25 1
C25/30 25 30 1.05
C30/37 30 37 1.12
C35/45 35 45 1.20
C40/50 40 50 1.25
C45/55 45 55 1.30
C50/60 50 60 1.35
Concrete cylinder:
height 30cm, 15cm
diameter
Concrete cube:
side length 15cm
Concrete test specimen geometry
(The Hilti CC method is a simplified version of ETAG Annex C.)
N
c
s
h
rec,c/s
|
.
|

\
| -
-
80
25 f
1 f
ck,cube
N B,
for f
ck,cube
= 20N/mm
|
|
.
|

\
| -
-
100
25 f
1 f
cube ck,
N B,
Limits:
25 N/mm s f
ck,cube
s 60 N/mm
HVU adhesive with HAS rod
Issue 2005 205
3
f
T
:Influence of anchorage depth
f
A,N
: Influence of anchor spacing
Anchor Anchor size
spacing,
s [mm] M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
40 0,63
45 0,64 0,63
50 0,66 0,64
55 0,67 0,65 0,63
60 0,69 0,67 0,64
65 0,70 0,68 0,65 0,63
70 0,72 0,69 0,66 0,64
80 0,75 0,72 0,68 0,66
90 0,78 0,75 0,70 0,68 0,63
100 0,81 0,78 0,73 0,70 0,65
120 0,88 0,83 0,77 0,74 0,68 0,64 0,63
140 0,94 0,89 0,82 0,78 0,71 0,67 0,65 0,63
160 1,00 0,94 0,86 0,82 0,74 0,69 0,67 0,65 0,63
180 1,00 0,91 0,86 0,76 0,71 0,69 0,67 0,65 0,64 0,63
200 0,95 0,90 0,79 0,74 0,71 0,69 0,67 0,65 0,64
220 1,00 0,94 0,82 0,76 0,73 0,70 0,68 0,67 0,65
250 1,00 0,87 0,80 0,76 0,73 0,71 0,69 0,67
280 0,91 0,83 0,79 0,76 0,73 0,71 0,69
310 0,96 0,87 0,82 0,79 0,76 0,73 0,72
340 1,00 0,90 0,85 0,81 0,78 0,76 0,74
390 0,96 0,91 0,86 0,83 0,80 0,77
420 1,00 0,94 0,89 0,85 0,82 0,79
450 0,97 0,92 0,88 0,84 0,81
480 1,00 0,94 0,90 0,86 0,83
540 1,00 0,95 0,91 0,88
600 1,00 0,95 0,92
660 1,00 0,96
720 1,00
f
R,N
: Influence of edge distance
Edge Anchor size
distance,
c [mm] M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
40 0,64
45 0,69 0,64
50 0,73 0,68
55 0,78 0,72 0,64
60 0,82 0,76 0,67
65 0,87 0,80 0,71 0,65
70 0,91 0,84 0,74 0,68
80 1,00 0,92 0,80 0,74
90 1,00 0,87 0,80 0,66
100 0,93 0,86 0,70
110 1,00 0,91 0,75 0,66
120 0,97 0,79 0,69 0,64
140 1,00 0,87 0,76 0,70 0,65
160 0,96 0,83 0,76 0,71 0,66
180 1,00 0,90 0,82 0,76 0,71 0,67 0,64
210 1,00 0,91 0,84 0,78 0,74 0,70
240 1,00 0,92 0,86 0,80 0,76
270 1,00 0,93 0,87 0,82
300 1,00 0,93 0,88
330 1,00 0,94
360 1,00
nom
act
T
h
h
f
Limits to actual anchorage depth h
act
: h
nom
s h
act
s 2.0 h
nom
nom
N , R
h
c
72 , 0 28 , 0 f -
Limits: c
min
s c s c
cr,N
c
min
= 0,5h
nom
c
cr,N
= 1,0h
nom
Note: If more than 3 edges
are smaller than c
cr,N
, consult
your Hilti technical advisory
service.
nom
N , A
h 4
s
5 , 0 f -
Limits: s
min
s s s s
cr,N
s
min
=0,5h
nom
s
cr,N
=2,0h
nom
HVU adhesive with HAS rod
206 Issue 2005
N
Rd,s
1)
: Steel design tensile resistance
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
HAS grade 5.8
2)
[kN] 10,9 17,4 25,4 48,1 75,1 108,1 142,3 173,0 215,7 253,1 304,3
HAS grade 8.8
2)
[kN] 17,5 27,9 40,7 78,9 120,1 172,9 227,8 276,8 345,2 404,9 486,9
HAS-R,HAS-HCR
2)3)
[kN] 12,3 19,6 28,6 54,0 84,3 121,0 89,0 108,1 134,8 158,2 190,2
1)
The design tensile resistance is calculated from the characteristic tensile resistance, N
Rk,s
, using N
Rd,s
= A
s
f
uk
/
Ms,N
, where the partial
safety factor,
Ms,N
, for grade 5.8 and 8.8 is 1.5; 1.87 for grades A4-70 and HCR of the M8 to M24 sizes and 2.4 for grades A4-70 and
HCR in the sizes M27 M39.
2)
Data given in italics applies to non-standard rods.
3)
Note: The values for the nominal tensile steel strength, f
uk
, for grade A4 change for the M27 to M39 sizes from 700 N/mm to 500 N/mm
and the yield strength, f
yk
, changes for the M27 to M39 sizes from 450 N/mm to 250 N/mm. The partial safety factor,
Ms,N
, changes with
the steel strengths as stated in note
1)
above.
N
Rd
: System design tensile resistance
N
Rd
= lower of N
Rd,c
and N
Rd,s
Combined loading: Only if tensile load and shear load applied (See page 31 and section 4 Examples).
Detailed design method Hilti CC
SHEAR
The design shear resistance of a single
anchor is the lower of
V
Rd,c
: concrete edge resistance
V
Rd,s
: steel resistance
Note: If the conditions for h and c
2
are not met, consult
your Hilti technical advisory service.
V
Rd,c
: Concrete edge design resistance
The lowest concrete edge resistance must be calculated. All near edges must be checked, (not only the edge in
the direction of shear). The direction of shear is accounted for by the factor f
,V.
V , V AR, V B,
0
c Rd, c Rd,
f f f V V
V
c
s
rec,c/s
c

>
1
.
5
c
2
c

>
1
.
5
c
2
h
>
1
.
5
c
(The Hilti CC method is a simplified version of ETAG Annex C.)
HVU adhesive with HAS rod
Issue 2005 207
3
V
0
Rd,c
: Concrete edge design resistance
- Concrete compressive strength, f
ck,cube(150)
= 25 N/mm
2
- at a minimum edge distance
min
c
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
V
o
Rd,c
1)
[kN] 2.6 3.4 5.0 6.7 12.4 18.5 23.6 30.2 36.8 44.3 52.1
c
min
[mm] min. edge distance 40 45 55 65 85 105 120 135 150 165 180
1)
The design shear resistance is calculated from the characteristic shear resistance, V
o
Rk,c
, using V
o
Rd,c
= V
o
Rk,c
/
Mc,V
, where the partial
safety factor,
Mc,V
, is 1.5.
f
B,V
: Influence of concrete strength
Concrete strength
designation
(ENV 206)
Cylinder compressive
strength,
f
ck,cyl
[N/mm]
Cube compressive
strength,
f
ck,cube
[N/mm]
f
B,N
C16/20 16 20 0.89
C20/25 20 25 1
C25/30 25 30 1.1
C30/37 30 37 1.22
C35/45 35 45 1.34
C40/50 40 50 1.41
C45/55 45 55 1.48
C50/60 50 60 1.55
Concrete cylinder:
height 30cm, 15cm
diameter
Concrete cube:
side length 15cm
Concrete test specimen geometry
f
AR,V
: Influence of spacing and edge distance
Formula for single-anchor fastening influenced
only by edge
min min
V , AR
c
c
c
c
f
Formula for two-anchor fastening (edge plus 1
spacing) only valid for s < 3c
min min
V , AR
c
c
c 6
s c 3
f
-

General formula for n-anchor fastening (edge plus n-1 spacing)


only valid where s
1
and s
n-1
are each < 3c and c2 > 1.5c
min min
1 n 2 1
V , AR
c
c
nc 3
s ... s s c 3
f
- - - -

-
25
cube ck,
V B,
f
f
Limits:
20 N/mm
2
s f
ck,cube
s 60 N/mm
2
c
c
s
s
s
2,2
1
2
3
n-1
s
c
2,1
h >1,5 c
Note: It is assumed that only the row of anchors closest to
the free concrete edge carries the centric shear load.
results
tabulated
below
HVU adhesive with HAS rod
208 Issue 2005
f
AR,V
: Influence of edge distance and spacing
f
AR,V
c/c
min
1,0 1,2 1,4 1,6 1,8 2,0 2,2 2,4 2,6 2,8 3,0 3,2 3,4 3,6 3,8 4,0
Single anchor with
edge influence,
1,00 1,31 1,66 2,02 2,41 2,83 3,26 3,72 4,19 4,69 5,20 5,72 6,27 6,83 7,41 8,00
s/c
min
1,0 0,67 0,84 1,03 1,22 1,43 1,65 1,88 2,12 2,36 2,62 2,89 3,16 3,44 3,73 4,03 4,33
1,5 0,75 0,93 1,12 1,33 1,54 1,77 2,00 2,25 2,50 2,76 3,03 3,31 3,60 3,89 4,19 4,50
2,0 0,83 1,02 1,22 1,43 1,65 1,89 2,13 2,38 2,63 2,90 3,18 3,46 3,75 4,05 4,35 4,67
2,5 0,92 1,11 1,32 1,54 1,77 2,00 2,25 2,50 2,77 3,04 3,32 3,61 3,90 4,21 4,52 4,83
3,0 1,00 1,20 1,42 1,64 1,88 2,12 2,37 2,63 2,90 3,18 3,46 3,76 4,06 4,36 4,68 5,00
3,5 1,30 1,52 1,75 1,99 2,24 2,50 2,76 3,04 3,32 3,61 3,91 4,21 4,52 4,84 5,17
4,0 1,62 1,86 2,10 2,36 2,62 2,89 3,17 3,46 3,75 4,05 4,36 4,68 5,00 5,33
4,5 1,96 2,21 2,47 2,74 3,02 3,31 3,60 3,90 4,20 4,52 4,84 5,17 5,50
5,0 2,33 2,59 2,87 3,15 3,44 3,74 4,04 4,35 4,67 5,00 5,33 5,67
5,5 2,71 2,99 3,28 3,57 3,88 4,19 4,50 4,82 5,15 5,49 5,83
6,0 2,83 3,11 3,41 3,71 4,02 4,33 4,65 4,98 5,31 5,65 6,00
6,5 3,24 3,54 3,84 4,16 4,47 4,80 5,13 5,47 5,82 6,17
7,0 3,67 3,98 4,29 4,62 4,95 5,29 5,63 5,98 6,33
7,5 4,11 4,43 4,76 5,10 5,44 5,79 6,14 6,50
8,0 4,57 4,91 5,25 5,59 5,95 6,30 6,67
8,5 5,05 5,40 5,75 6,10 6,47 6,83
9,0 5,20 5,55 5,90 6,26 6,63 7,00
9,5 5,69 6,05 6,42 6,79 7,17
10,0 6,21 6,58 6,95 7,33
10,5 6,74 7,12 7,50
11,0 7,28 7,67
11,5 7,83
12,0 8,00
f
,V
: Influence of shear loading direction
Angle, []
f
,V
0 to 55 1
60 1.1
70 1.2
80 1.5
90 to 180 2
V
Rd,s
1)
: Steel design shear resistance
Anchor size M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
HAS grade 5.8
2)
[kN] 7,9 12,6 18,3 34,6 54,0 77,8 102,5 124,6 155,3 182,2 219,1
HAS grade 8.8
2)
[kN] 12,6 20,1 29,3 55,3 86,4 124,4 164,0 199,3 248,4 291,5 350,6
HAS-R, HAS-HCR
2) 3)
[kN] 8.8 14.1 20.5 38.8 60.6 87.2 64.1 77.9 97.1 113.9 137
1)
The design shear resistance is calculated using V
Rd,s
= (0,6 A
s
f
uk
)/
Ms,V
. The values for the stressed cross-section, A
s
, and the nominal
tensile strength of steel, f
uk
, are given in the table Anchor mechanical properties and geometry. The partial safety factor,
Ms,V
, is 1.25 for
grades 5.8 and 8.8; 1.56 for grade sA4-70 and HCR in the sizes M8 to M24, and 2.0 for grade A4-70 in the sizes M27 to M39.
2)
Data given in italics applies to non-standard rods.
3)
Note: The values for the nominal tensile strength of steel, f
uk
, for grade A4-70 change for the M27 to M39 sizes from 700 N/mm to 500
N/mm and the yield strength, f
yk
, changes for the M27 to M39 sizes from 450N/mm
2
to 250N/mm
2
. The partial safety factor,
Ms,V
,
changes the steel strengths as stated in note
1)
above.
V
Rd
: System design shear resistance
V
Rd
= lower of V
Rd,c
and V
Rd,s
Combined loading: Only if tensile load and shear load applied (See page 31 and section 4 Examples).
V ... applied shear force

1 f
V ,

sin 5 . 0 cos
1
f
V ,
2 f
V ,

for 0 s s 55
for 55 < s 90
for 90 < s 180
Formulae:
These results are for a two-
anchor fastening.
For fastenings with more than
two anchors, use the general
formulae for n anchors.
HVU adhesive with HIS-N/HIS-RN sleeve
Issue 2005 209
Features:
- anchor fastenings flush with surface
- foil capsule vs. glass
- no expansion force in base material
- high loading capacity
- small edge distance and spacing
- complete system consisting of robust foil capsule,
internally threaded sleeve and setting tool
Material:
HIS-N: - carbon steel galvanised to 5 microns
HIS-RN - stainless steel, A4-70: 1.4401
HVU capsule:
- urethane methacrylate resin, styrene free,
hardener, quartz sand or corundum, foil tube
HVU capsule
HIS-N, HIS-RN internally threaded sleeves
A4
316
Concrete
Small edge
distance/
spacing
Fire
resistance
Corrosion
resistance
Hilti Anchor
programme
Basic loading data (for a single anchor): HIS-N
All data on this page applies to For detailed design method, see pages 212 217.
- concrete: See table below.
- correct setting (See setting operations page 211)
- no edge distance and spacing influence
- tensile values are for HIS-N (derived using grade 12.9 rods)
- shear (steel failure): rod / bolt of steel grade 5.8
Mean ultimate resistance, R
u,m
[kN]: concrete = C20/25
Anchor size M8 M10 M12 M16 M20
Tensile, N
Ru,m
37.2 85.1 102.4 161.3 210.0
Shear, V
Ru,m
11.9 18.8 27.3 50.9 79.4
Characteristic resistance, R
k
[kN]: concrete = C20/25
Anchor size M8 M10 M12 M16 M20
Tensile, N
Rk
35.6 81.6 66.9 150.3 174.3
Shear, V
Rk
11.0 17.4 25.3 47.1 73.5
Following values according to the
Concrete Capacity Method
Design resistance, R
d
[kN]: concrete, f
ck,cube
= 25 N/mm
2
Anchor size M8 M10 M12 M16 M20
Tensile, N
Rd
12.2 19.3 28.1 52.3 81.7
Shear, V
Rd
8.8 13.9 20.2 37.7 58.8
Recommended load, L
rec
[kN]: concrete, f
ck,cube
= 25 N/mm
2
Anchor size M8 M10 M12 M16 M20
Tensile, N
Rec
8.7 13.8 20.1 37.4 58.6
Shear, V
Rec
6.3 9.9 14.5 26.9 42.0
non-cracked concrete
3
HVU adhesive with HIS-N/HIS-RN sleeve
210 Issue 2005
Basic loading data (for a single anchor): HIS-RN
All data on this section applies to For detailed design method, see pages 212 217.
- concrete: See table below.
- correct setting (See setting operations page 211)
- no edge distance and spacing influence
- tensile values are for HIS-RN (derived using grade 12.9 rods)
- shear (steel failure): rod / bolt of steel grade A4-70
Mean ultimate resistance, R
u,m
[kN]: concrete = C20/25
Anchor size M8 M10 M12 M16 M20
Tensile, N
Ru,m
40.5 85.1 102.4 161.3 173.1
Shear, V
Ru,m
16.6 26.3 38.2 71.2 111.1
Characteristic resistance, R
k
[kN]: concrete = C20/25
Anchor size M8 M10 M12 M16 M20
Tensile, N
Rk
37.5 81.6 66.9 150.3 160.3
Shear, V
Rk
15.4 24.4 35.4 65.9 102.9
Following values according to the
Concrete Capacity Method
Design resistance, R
d
[kN]: concrete, f
ck,cube
= 25 N/mm
2
Anchor size M8 M10 M12 M16 M20
Tensile, N
Rd
13.7 21.7 31.6 58.8 91.7
Shear, V
Rd
9.9 15.6 22.7 42.3 66.0
Recommended load, L
rec
[kN]: concrete, f
ck,cube
= 25 N/mm
2
Anchor size M8 M10 M12 M16 M20
Tensile, N
Rec
9.8 15.5 22.5 42.0 65.5
Shear, V
Rec
7.1 11.1 16.2 30.2 47.1
Setting details
h
s
d
f
d
0
min
h
1
h
nom
h
non-cracked concrete
HVU adhesive with HIS-N/HIS-RN sleeve
Issue 2005 211
3
Anchor size M8 M10 M12 M16 M20
Foil capsule HVU... M10x90 M12x110 M16x125 M20x170 M24x210
Sleeve HIS-N ..., HIS-RN ... M8x90 M10x110 M12x125 M16x170 M20x205
d
0
[mm] Drill bit diameter 14 18 22 28 32
h
1
[mm] Hole depth 90 110 125 170 205
h
min
[mm] Min. thickness of base material 120 150 170 230 280
h
s
[mm]
Thread engagement min
length max
8
20
10
25
12
30
16
40
20
50
d
f
[mm] Rec. clearance hole 9 12 14 18 22
T
inst
[Nm]
Tightening torque HIS-N
HIS-RN
15
12
28
23
50
40
85
70
170
130
Drill bit TE-CX- 14/22 - - - -
Drill bit TE-T- - 18/32 22/32 28/32 32/37
Temperature when setting:
Min. time to wait before
removing SCREWED-ON
setting tool,
t
rel
Curing time before anchor
can be fully loaded,
t
cure
20C and above
10C to 20C
0C to 10C
-5C to 0C
8 min.
20 min.
30 min.
1 hour
20 min.
30 min.
1 hour
5 hours
Installation equipment
Rotary hammer (TE5, TE6, TE6A, TE15, TE15-C, TE18-M, TE 55 or TE 76), a drill bit, a setting tool, a TE
adapter (TE-C-HIS, TE-F-Y-HIS) with HIS-S - M8 - M20 and a blow-out pump.
Setting operations
1 2 3
HVU
5 4
HIS-N
Drill hole.
Blow out dust and
fragments.
Insert HVU capsule. Drive in anchor.
5
t
rel
6
t
cure
7
T
inst
Allow rel time to pass. Wait for curing. Apply tightening torque.
HVU adhesive with HIS-N/HIS-RN sleeve
212 Issue 2005
Anchor geometry and mechanical properties
Anchor size M8 M10 M12 M16 M20
Capsule HVU ... M10x90 M12x110 M16x125 M20x170 M24x210
l
p
[mm] Capsule length 110 127 140 170 200
d
p
[mm] Capsule diameter 10,7 13,1 17,1 22 25,7
Element HIS-N ..., HIS-RN ... M8x90 M10x110 M12x125 M16x170 M20x210
l [mm] Sleeve length 90 110 125 170 210
d [mm]
Sleeve outside
diameter
12,5 16,5 20,5 25,4 27,6
A
s
[mm] Stressed cross-section
Sleeve
Bolt
53,6
36,6
110
58,0
170
84,3
255
157
229
245
f
uk
[N/mm]
Nominal tensile
strength
HIS-N
HIS-RN
510
700
510
700
460
700
460
700
460
700
f
yk
[N/mm] Yield strength
HIS-N
HIS-RN
410
350
410
350
375
350
375
350
375
350
W [mm] Moment of resistance of bolt 31,2 62,3 109 277 375
M
Rd,s
[Nm]
Design bending
resistance of bolt
1)
5.8
8.8
A2/A4
12,7
20,4
14,3
25,6
41,0
28,7
45,1
75,1
50,6
117,1
187,4
131,4
228,8
366,1
256,7
1)
The design bending resistance of the bolt is calculated from M
Rd,s
= (1,2 W f
uk
)/
ms,b
, where the partial safety factor,

ms,b
, for grade 5.8 and 8.8 bolts is 1.25 and 1.56 for A4-70 and A2-70. The final safety check is then M
Sk

F
s M
Rd,s
.
Detailed design method - Hilti CC
Caution: In view of the high loads transferable with the HVU, it must be verified by the user that the load
acting on the concrete structure, including the loads introduced by the anchor fastening, do not cause failure,
e.g. cracking, of the concrete structure.
TENSION
The design tensile resistance of a single anchor
is the lower of
N
Rd,c
: concrete cone/pull-out resistance
N
Rd,s
: steel resistance of the bolt or sleeve
(The Hilti CC method is a simplified version of ETAG Annex C.)
d
p
l
p l
l
d
d
p
l
p
HVU M.. HVU M.. HVU M..
N
c
s
h
rec,c/s
HVU adhesive with HIS-N/HIS-RN sleeve
Issue 2005 213
3
N
Rd,c
: Concrete cone/pull-out resistance
N , R N , A N , B
o
c , Rd c , Rd
f f f N N
N
0
Rd,c
: Concrete cone/pull-out design resistance
- Concrete compressive strength, f
ck,cube(150)
= 25 N/mm
2
Anchor size M8 M10 M12 M16 M20
N
o
Rd,c
[kN] 22.6 35.4 46.9 85.1 120.1
h
nom
[mm] Nominal anchorage depth 90 110 125 170 205
1)
The design tensile resistance is calculated from the characteristic tensile resistance, N
o
Rk,c
, by N
o
Rd,c
= N
o
Rk,c
/
Mc,N
, where the partial
safety factor,
Mc,N
, is 1.8.
f
B,N
: Influence of concrete strength
Concrete strength
designation
(ENV 206)
compressive cylinder
strength,
f
ck,cyl
[N/mm]
compressive cube
strength,
f
ck,cube
[N/mm]
f
B,N
C16/20 16 20 0.95
C20/25 20 25 1
C25/30 25 30 1.04
C30/37 30 37 1.10
C35/45 35 45 1.16
C40/50 40 50 1.20
C45/55 45 55 1.24
C50/60 50 60 1.28
Concrete cylinder:
height 30cm, 15cm
diameter
Concrete cube:
side length 15cm
Concrete test specimen geometry
f
A,N
: Influence of anchor spacing
Anchor size
Spacing,
s [mm]
M8 M10 M12 M16 M20
45 0.63
50 0.64
55 0.65 0.63
60 0.67 0.64
65 0.68 0.65 0.63
70 0.69 0.66 0.64
80 0.72 0.68 0.66
90 0.75 0.70 0.68 0.63
100 0.78 0.73 0.70 0.65
110 0.81 0.75 0.72 0.66 0.63
120 0.83 0.77 0.74 0.68 0.65
140 0.89 0.82 0.78 0.71 0.67
160 0.94 0.86 0.82 0.74 0.70
180 1.00 0.91 0.86 0.76 0.72
200 0.95 0.90 0.79 0.74
220 1.00 0.94 0.82 0.77
250 1.00 0.87 0.80
280 0.91 0.84
310 0.96 0.88
340 1.00 0.91
390 0.98
410 1.00
nom
N , A
h 4
s
5 . 0 f

-
Limits: s
min
s s s s
cr,N
s
min
= 0,5h
nom
s
cr,N
= 2,0h
nom
|
|
.
|

\
| -
-
100
25 f
1
cube ck,
N B,
f
for f
ck,cube(150)
=20 N/mm
|
|
.
|

\
| -
-
125
25 f
1
cube ck,
N B,
f
Limits: 25 N/mm s f
ck,cube(150)
s 60 N/mm
HVU adhesive with HIS-N/HIS-RN sleeve
214 Issue 2005
f
R,N
: Influence of edge distance
Anchor size Edge
distance,
c [mm]
M8 M10 M12 M16 M20
45 0.64
50 0.68
55 0.72 0.64
60 0.76 0.67
65 0.80 0.71 0.65
70 0.84 0.74 0.68
80 0.92 0.80 0.74
90 1.00 0.87 0.80 0.66
100 0.93 0.86 0.70
110 1.00 0.91 0.75 0.67
120 0.97 0.79 0.70
140 1.00 0.87 0.77
160 0.96 0.84
180 1.00 0.91
210 1.00
N
Rd,s
1)
: Steel design tensile resistance
Anchor size M8 M10 M12 M16 M20
N
Rd
sleeve
,s
[kN] Sleeve HIS-N
HIS-RN
18,2
15,6
37,4
32,1
52,1
49,6
78,2
74,4
70,2
66,8
N
Rd s
bolt
,
[kN] Bolt grade 5.8
grade 8.8
grade A4-70
12,2
19,5
13,7
19,3
30,9
21,7
28,1
44,9
31,6
52,3
84,0
58,8
81,7
130,7
91,7
1)
The design tensile resistance is calculated from the characteristic tensile resistance, N
Rk,s
, by N
Rd,s
= A
s
f
uk
/
Ms,N
, where the partial
safety factor,
Ms,N
, for the sleeve / bolts of grades 5.8 and 8.8 is 1.5 or 1.87 for grade A4-70 and 2.4 for the sleeve.
N
Rd
: System design tensile resistance
N
Rd
= lower of N
Rd,c
, N
Rd,s
sleeve
or N
Rd,s
bolt
Combined loading: Only if tensile load and shear load applied (See page 31 and section 4 Examples).
nom
N , R
h
c
72 . 0 28 . 0 f -
Limits: c
min
s c s c
cr,N
c
min
= 0,5 h
nom
c
cr,N
= 1,0 h
nom
Note: If more than 3 edges are smaller than
c
cr,N
, consult your Hilti technical advisory
service.
HVU adhesive with HIS-N/HIS-RN sleeve
Issue 2005 215
3
Detailed design method Hilti CC
SHEAR
The design shear resistance of a single
anchor is the lower of
V
Rd,c
: concrete edge resistance
V
Rd,s
: steel resistance of the bolt
V
Rd,c
: Concrete edge design resistance
The lowest concrete edge resistance must be calculated. All near edges must be checked (not only the edge in
the direction of shear). The direction of shear is accounted for by the factor f
,V
.
V AR, V , V B,
0
c Rd, c Rd,
f f f V V
V
0
Rd,c
: Concrete edge design resistance
- concrete compressive strength, f
ck,cube(150)
= 25 N/mm
2
- at a minimum edge distance
min
c
Anchor size M8 M10 M12 M16 M20
V
0
Rd,c
1)
[kN] 3.6 5.4 7.6 12.8 19.2
c
min
[mm] Min. edge distance 45 55 65 85 105
1)
The design shear resistance is calculated from the characteristic shear resistance, V
o
Rk,c
, by V
o
Rd,c
= V
o
Rk,c
/
Mc,V
, where the partial safety
factor,
Mc,V
, is 1.5.
f
BV
: Influence of concrete strength
Concrete strength
designation
(ENV 206)
Cylinder compressive
strength,
f
ck,cyl
[N/mm]
Cube compressive
strength,
f
ck,cube
[N/mm]
f
B,V
C16/20 16 20 0.89
C20/25 20 25 1
C25/30 25 30 1.1
C30/37 30 37 1.22
C35/45 35 45 1.34
C40/50 40 50 1.41
C45/55 45 55 1.48
C50/60 50 60 1.55
Concrete cylinder:
height 30cm, 15cm
diameter
Concrete cube:
side length 15cm
Concrete test specimen geometry
V
c
s
rec,c/s
c
>
1
.
5
c
2
c
>
1
.
5
c
2
h
>
1
.
5
c
Note: If the conditions for h and c
2
are not met, consult
your Hilti technical advisory service.
25
f
f
cube , ck
V , B

Limits:
20 N/mm
2
s f
ck,cube(150)
s 60 N/mm
2
(The Hilti CC method is a simplified version of ETAG Annex C.)
HVU adhesive with HIS-N/HIS-RN sleeve
216 Issue 2005
c
c
s
s
s
2,2
1
2
3
n-1
s
c
2,1
h >1,5 c
Note: It is assumed that only the row of anchors closest to
the free concrete edge carries the centric shear load.
f
,V
: Influence of loading direction
Angle, [] f
,V
0 to 55 1
60 1.1
70 1.2
80 1.5
90 to 180 2
f
AR,V
: Formulae for edge distance and spacing influence
Formula for single-anchor fastening influenced
only by edge
min min
V , AR
c
c
c
c
f
Formula for two-anchor fastening anchors (edge
plus 1 spacing) only valid for s < 3c
min min
V , AR
c
c
c 6
s c 3
f

General formula for n-anchor fastening (edge plus n-1 spacing)


only valid where s
1
and s
n-1
are each < 3c and c
2
> 1.5c
min min
1 n 2 1
V , AR
c
c
c n 3
s ... s s c 3
f

- - - -

-
f
AR,V
: Influence of edge distance and spacing
c/c
min
f
AR,V
1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0
Single anchor with
edge influence,
1.00 1.31 1.66 2.02 2.41 2.83 3.26 3.72 4.19 4.69 5.20 5.72 6.27 6.83 7.41 8.00
s/c
min
1.0 0.67 0.84 1.03 1.22 1.43 1.65 1.88 2.12 2.36 2.62 2.89 3.16 3.44 3.73 4.03 4.33
1.5 0.75 0.93 1.12 1.33 1.54 1.77 2.00 2.25 2.50 2.76 3.03 3.31 3.60 3.89 4.19 4.50
2.0 0.83 1.02 1.22 1.43 1.65 1.89 2.13 2.38 2.63 2.90 3.18 3.46 3.75 4.05 4.35 4.67
2.5 0.92 1.11 1.32 1.54 1.77 2.00 2.25 2.50 2.77 3.04 3.32 3.61 3.90 4.21 4.52 4.83
3.0 1.00 1.20 1.42 1.64 1.88 2.12 2.37 2.63 2.90 3.18 3.46 3.76 4.06 4.36 4.68 5.00
3.5 1.30 1.52 1.75 1.99 2.24 2.50 2.76 3.04 3.32 3.61 3.91 4.21 4.52 4.84 5.17
4.0 1.62 1.86 2.10 2.36 2.62 2.89 3.17 3.46 3.75 4.05 4.36 4.68 5.00 5.33
4.5 1.96 2.21 2.47 2.74 3.02 3.31 3.60 3.90 4.20 4.52 4.84 5.17 5.50
5.0 2.33 2.59 2.87 3.15 3.44 3.74 4.04 4.35 4.67 5.00 5.33 5.67
5.5 2.71 2.99 3.28 3.57 3.88 4.19 4.50 4.82 5.15 5.49 5.83
6.0 2.83 3.11 3.41 3.71 4.02 4.33 4.65 4.98 5.31 5.65 6.00
6.5 3.24 3.54 3.84 4.16 4.47 4.80 5.13 5.47 5.82 6.17
7.0 3.67 3.98 4.29 4.62 4.95 5.29 5.63 5.98 6.33
7.5 4.11 4.43 4.76 5.10 5.44 5.79 6.14 6.50
8.0 4.57 4.91 5.25 5.59 5.95 6.30 6.67
8.5 5.05 5.40 5.75 6.10 6.47 6.83
9.0 5.20 5.55 5.90 6.26 6.63 7.00
9.5 5.69 6.05 6.42 6.79 7.17
10.0 6.21 6.58 6.95 7.33
10.5 6.74 7.12 7.50
11.0 7.28 7.67
11.5 7.83
12.0 8.00
1
V ,
f

sin 5 , 0 cos
1
V ,
f
-

2
V ,
f

for 0 s s 55
for 55 < s 90
for 90 < s 180
Formulae:
V ... applied shear force

These results are for a two-


anchor fastening.
For fastenings with more than
two anchors, use the general
formulae for n anchors at the
top of the page.
results
tabulated
below
HVU adhesive with HIS-N/HIS-RN sleeve
Issue 2005 217
3
V
Rd,s
: Steel design shear resistance
Anchor size M8 M10 M12 M16 M20
V
Rd,s
1)
[kN] Bolt steel grade 5.8 8.8 13.9 20.2 37.7 58.8
steel grade 8.8 14.1 22.3 32.4 60.3 94.1
A4-70 9.9 15.6 22.7 42.3 66.0
1)
The design shear resistance is calculated from V
Rd,s
= (0,6 A
s
f
uk
)/
Ms,V
. The values for the stressed cross-section, A
s
, of the bolt and
the nominal tensile steel strength, f
uk
, are taken from the bolt standard ISO 898. The partial safety factor,
Ms,V
, for grades 5.8 and 8.8
is 1.25 and 1.56 for grade A4-70.
V
Rd
: System design shear resistance
V
Rd
= lower of V
Rd,c
and V
Rd,s
bolt
Combined loading: Only if tensile load and shear load applied (See page 31 and section 4 Examples).
HVZ adhesive anchor
180 Issue 2005
Features:
- foil capsule vs. glass
- flexibly to fit in irregular holes
- marking for identification after setting
- test reports: fire, dynamic (fatigue, shock), water
tightness
Material:
HVU-(E-)TZ:
- urethane methacrylate resin styrene free,
hardener,
quartz sand, foil tubes
HAS-(E-)TZ:
- grade 8.8; EN ISO 20898-1; coating: DIN 50968-
FE/Cu 3 Ni 10
HAS-(E-)RTZ: - stainless steel; A4-80; 1.4401; 14571; EN 10088
HAS-(E-)HCR-TZ: - stainless steel; 1.4529; 1.4547; EN 10088-3
HVU-TZ capsule
HAS-TZ, HAS-RTZ and
HAS-HCR-TZ anchor rod
Concrete Tensile zone
Close edge
distance/
spacing
Fatigue Shock
A4
316
HCR
highMo
Corrosion
resistance
High corrosion
resistance
Fire resistance
Hilti Anchor
programme
Basic loading data (for a single anchor): HAS-(E-)TZ
All data on this page applies to For detailed design method, see pages 184 189.
- concrete: See table below.
- correct setting (See setting operations page 183)
- no edge distance and spacing influence
- steel failure
Mean ultimate resistance R
u,m
[kN]: concrete = C20/25
Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20
Tensile N
Ru,m
38.2 49.0 82.1 82.1 132.9 38.2 49.0 68.7 72.0 132.9
Shear V
Ru,m
20.1 29.2 54.2 54.2 93.3 20.1 29.2 54.2 54.2 93.3
Characteristic resistance, R
k
[kN]: concrete = C20/25
Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20
Tensile N
Rk
32.7 40.0 54.3 70.5 111.8 20.0 33.3 38.7 50.3 79.8
Shear V
Rk
18.0 27.0 51.0 51.0 88.0 18.0 27.0 51.0 51.0 88.0
Following values according to the:
Concrete Capacity Method
Design resistance, R
d
[kN]: concrete f
ck,cube
= 25 N/mm
2
Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20
Tensile N
Rd
21.8 26.7 36.2 47.0 74.5 13.3 22.2 25. 8 33.5 53.2
Shear V
Rd
14.4 21.6 40.8 40.8 70.4 14.4 21.6 40.8 40.8 70.4
Recommended load, L
rec
[kN]: concrete f
ck,cube
= 25 N/mm
2
Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20
Tensile N
Rec
15.6 19.1 25.8 33.6 53.2 9.5 15.9 18.4 23.9 38.0
Shear V
Rec
10.3 15.4 29.1 29.1 50.3 10.3 15.4 29.1 29.1 50.3
non-cracked concrete cracked concrete
HVZ adhesive anchor
Issue 2005 181
Basic loading data (for a single anchor): HAS-(E-)RTZ
All data on this section applies to For detailed design method, see pages 184 189.
- concrete: See table below.
- correct setting (See setting operations page 183)
- no edge distance and spacing influence
- steel failure
Mean ultimate resistance, R
u,m
[kN]: concrete = C20/25
Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20
Tensile N
Ru,m
38.2 49.0 82.1 82.1 132.9 38.2 49.0 68.7 72.0 132.9
Shear V
Ru,m
22.6 32.7 61.0 61.0 103.9 22.6 32.7 61.0 61.0 103.8
Characteristic resistance, R
k
[kN]: concrete = C20/25
Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20
Tensile N
Rk
32.7 40.0 54.3 70.5 111.8 20.0 33.3 38.7 50.3 79.8
Shear V
Rk
20.0 30.0 56.0 56.0 98.0 20.0 30.0 56.0 56.0 98.0
Following values according to the:
Concrete Capacity Method
Design resistance, R
d
[kN]: concrete f
ck,cube
= 25 N/mm
2
Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20
Tensile N
Rd
21.8 26.7 36.2 47.0 74.5 13.3 22.2 25..8 33.5 53.2
Shear V
Rd
16.0 24.0 44.8 44.8 78.4 16.0 24.0 44.8 44.8 78.4
Recommended load, L
rec
[kN]: concrete f
ck,cube
= 25 N/mm
2
Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20
Tensile N
Rec
15.6 19.1 25.8 33.6 53.2 9.5 15.9 18.4 23.9 38.0
Shear V
Rec
11.4 17.1 32.0 32.0 56.0 11.4 17.1 32.0 32.0 56.0
Basic loading data (for a single anchor): HAS-(E-)HCR-TZ
All data on this section applies to For detailed design method, see pages 184 189.
- concrete: See table below.
- correct setting (See setting operations page 183)
- no edge distance and edge influence
- steel failure
Mean ultimate resistance, R
u,m
[kN]: concrete = C20/25
Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20
Tensile N
Ru,m
38.2 49.0 82.1 82.1 132.9 38.2 49.0 68.7 72.0 132.9
Shear V
Ru,m
25.1 36.4 61.0 61.0 105.8 25.1 36.4 61.0 61.0 105.8
non-cracked concrete cracked concrete
non-cracked concrete cracked concrete
3
HVZ adhesive anchor
182 Issue 2005
Characteristic resistance R
k
[kN]: concrete = C20/25
Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20
Tensile N
Rk
32.7 40.0 54.3 70.5 111.8 20.0 33.3 38.7 50.3 79.8
Shear V
Rk
20.0 30.0 56.0 56.0 98.0 20.0 30.0 56.0 56.0 98.0
Following values according to the:
Concrete Capacity Method
Design resistance R
d
[kN]: concrete f
ck,cube
= 25 N/mm
2
Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20
Tensile N
Rd
21.8 26.7 36.2 47.0 74.5 13.3 22.2 25..8 33.5 53.2
Shear V
Rd
16.0 24.0 44.8 44.8 78.4 16.0 24.0 44.8 44.8 78.4
Recommended load, L
rec
[kN]: concrete f
ck,cube
= 25 N/mm
2
Anchor size M10 M12 M16 M16L M20 M10 M12 M16 M16L M20
Tensile N
Rec
15.6 19.1 25.8 33.6 53.2 9.5 15.9 18.4 23.9 38.0
Shear V
Rec
11.4 17.1 32.0 32.0 56.0 11.4 17.1 32.0 32.0 56.0
Setting details
Anchor size M10x75 M12x95 M16x105 M16x125 M20x170
Foil capsule HVU-TZ M.. 10x90 12x110 16x125 20x190
Anchor rod HAS-(E-)TZ M.. 10x75/ t
fix
12x95/ t
fix
16x105/ t
fix
16Lx125/t
fix
20x170/ 40
d
0
[mm] Drill bit diameter 12 14 18
25
h
1
[mm] Hole depth 90 110 125 145 195
h
min
[mm] Min. thickness of base material 150 190 210 250 340
t
fix
[mm] Max. fixture thickness 15 / 30 / 50
25 / 50 / 100
(and 40 for
HAS-RTZ)
30 / 60 / 100 40
d
f
[mm]
Clearance hole rec.
(without bending verification) max.
12
13
14
15
18
19
22
T
inst
[Nm]
Tightening HAS-TZ
Torque HAS-R/HCR-TZ
40
50
50
70
90
100
150
Drill bit
TECX 12/22
TE-TX 12/32
TECX 14/22
TE-TX 14/32
TEC 18/32S
TE-T 18/32
TEC 25/27S
TE-T 25/32
d
0
d
f
t
fix
h
ef
h
1
h
min
H
V
Z
...
HAS-E-TZ
HAS-TZ
HVZ adhesive anchor
Issue 2005 183
3
Base material temperature Min. time to wait before
removing SCREWED-ON
setting tool (not applicable for
TE-C HEX):
t
rel
Curing time:
t
cure
20C and higher
10C to 20C
0C to 10C
-5C to 0C
8 min.
20 min.
30 min.
1 hour
20 min.
30 min.
1 hour
5 hours
less than -5C Please consult your Hilti technical service.
Installation equipment
A rotary hammer (TE5, TE6, TE15, TE-15C, TE-18M, TE35, TE55, TE76); max. setting speed of 850 r.p.m
(rotary hammering action); a drill bit, a blow out pump and a setting tool: TE-C HEX (M10-M16), TE-Y HEX
(M20);
Setting operations
1 2 3

HVU-TZ
4
TE-C HEX
Drill hole.
Blow out dust and
fragments.
Insert HVU-TZ capsule.
Drive in with rotary
hammering action.
t
rel
5
t
cure
6
7 T
inst
Allow rel time to pass Wait for curing Apply tightening torque.
Anchor geometry and mechanical properties
d
p
l
p
HVU-TZ M.. HVU-TZ M..
Marking of material and anchorage depth
for HAS-TZ: HVZ...
for HAS-RTZ: HVZ R...
for HAS-HCR: HVZ HCR...
d
d
k
h
ef
l
S
w
d
w
HVZ adhesive anchor
184 Issue 2005
Anchor size M10 M12 M16x105 M16x125 M20
HVU-TZ capsule:
l
p
[mm] HVU-TZ foil capsule length 110 127 140 200
d
p
[mm] HVU-TZ foil capsule diameter 11.0 13.0 17.0 23.0
HAS-(E-)TZ/-RTZ/-HCR-TZ:
Stressed cross-sectional area
under tensile loading:
44.2 56.7 95.0 153.9
A
s
[mm]
Stressed cross-sectional area
under shear loading in thread:
58.0 84.3 157.0 245.0
f
uk
[N/mm]
Nominal tensile
strength (point)
HAS-TZ 8.8
HAS-RTZ
HAS-HCR-TZ
800
800
800
f
yk
[N/mm]
Nominal yield
strength (point)
HAS-TZ 8.8
HAS-RTZ
HAS-HCR-TZ
640
600
600
W [mm] Section modulus 62.3 109.0 277.0 541
M
Rd,s
[Nm]
Design bending
resistance
HAS-TZ 8.8
HAS-RTZ and
HAS-HCR-TZ
38.4 68.8 181.6 415.2
d [mm] Shank diameter 10 12 16 20
d
k
[mm] Anchor end diameter 10.8 12.8 16.8 22.7
h
ef
[mm] Actual anchorage depth 75 95 105 125 170
l [mm] Anchor length 124/139/159 158/183/233 181/211/251 201/231/271 269
S
w
[mm] Width across flats 17 19 24 30
d
w
[mm] Washer outside diameter 20 24 30 37
1)
The design bending resistance of the anchor rod was calculated using M
Rd,s
= M
Rk,s
/
Ms,b
, where the partial safety factor
Ms,b
is 1.25.
Detailed design method - Hilti CC
Caution: In view of the high loads transferable with HVZ, it must be verified by the user that the load on the
concrete structure including the loads introduced by the anchorage do not cause failure (e.g. cracking) of the
concrete structure.
TENSION
The tensile design resistance of a single anchor
is the lower of,
N
Rd,c
: concrete cone/pull-out resistance
N
Rd,s
: steel resistance
(The Hilti CC-Method is a simplified Version of ETAG Annex C)
N
c
s
h
rec,c/s
HVZ adhesive anchor
Issue 2005 185
3
N
Rd,c
: Concrete cone/pull-out resistance
N , R N , A N , B
o
c , Rd c , Rd
f f f N N
N
0
Rd,c
: Concrete cone/pull-out design resistance
- Concrete compressive strength f
ck,cube(150)
= 25 N/mm
2
Anchor size M10 M12 M16 M16L M20
N
0
Rd,c
1)
[kN] in non-cracked concrete
21.8 26.7 36.2 47.0 74.5
N
0
Rd,c
1)
[kN] in cracked concrete
13.3 22.2 25.8 33.5 53.2
h
ef
[mm] Actual anchorage depth 75 95 105 125 170
1)
The design tensile resistance is calculated from the characteristic tensile resistance N
o
Rk,c
by N
o
Rd,c
= N
o
Rk,c
/
Mc,N
, where the partial
safety factor
Mc,N
is 1.5.
f
B,N
: Influence of concrete strength
Concrete strength
designation
(ENV 206)
Cylinder compressive
strength
f
ck,cyl
[N/mm]
Cube compressive
strength
f
ck,cube
[N/mm]
f
B,N
C20/25 20 25 1
C25/30 25 30 1.1
C30/37 30 37 1.22
C35/45 35 45 1.34
C40/50 40 50 1.41
C45/55 45 55 1.48
C50/60 50 60 1.55
Concrete cylinder:
height 30cm, 15cm
diameter
Concrete cube:
side length 15cm
Concrete test specimen geometry
f
A,N
: Influence of spacing
Spacing, Anchor size
s [mm] M10 M12 M16 M16L M20
50 0.61
60 0.63 0.60
65 0.64 0.61
70 0.66 0.62 0.61 0.59
75 0.67 0.63 0.62 0.60
80 0.68 0.64 0.63 0.61 0.58
85 0.69 0.65 0.63 0.61 0.58
90 0.70 0.66 0.64 0.62 0.59
100 0.72 0.68 0.66 0.63 0.60
120 0.77 0.71 0.69 0.66 0.62
135 0.80 0.74 0.71 0.68 0.63
140 0.81 0.75 0.72 0.69 0.64
160 0.86 0.78 0.75 0.71 0.66
180 0.90 0.82 0.79 0.74 0.68
200 0.94 0.85 0.82 0.77 0.70
220 1.00 0.89 0.85 0.79 0.72
240 0.92 0.88 0.82 0.74
25
f
f
cube ck,
N B,

Limits: 25 N/mm
2
s f
ck,cube
s 60 N/mm
2
HVZ adhesive anchor
186 Issue 2005
f
A,N
: Influence of spacing
Spacing, Anchor size
s [mm] M10 M12 M16 M16L M20
270 0.97 0.93 0.86 0.76
300 1.00 0.98 0.90 0.79
330 1.00 0.94 0.82
360 0.98 0.85
390 1.00 0.88
420 0.91
450 0.94
480 0.97
510 1.00
f
R,N
: Influence of edge distance
Edge Anchor size
distance
,
c [mm]
M10 M12 M16 M16L M20
50 0.58
60 0.65
65 0.68
70 0.72 0.62
75 0.75 0.64
80 0.78 0.67 0.49
85 0.82 0.70 0.65 0.59
0.50
90 0.85 0.72 0.68 0.61
0.51
95 0.88 0.75 0.70 0.63
0.53
100 0.92 0.78 0.73 0.65
0.54
105 0.95 0.80 0.75 0.67
0.56
110 0.98 0.83 0.77 0.69
0.57
115 1.00 0.86 0.80 0.71
0.59
125 0.91 0.85 0.75
0.62
135 0.96 0.89 0.79
0.65
145 1.00 0.94 0.83
0.68
155 1.00 0.87
0.71
165 0.91
0.74
175 0.95
0.76
185 1.00
0.79
205
0.85
230
0.93
255
1.00
ef
N , R
h
c
50 . 0 25 . 0 f - Limits: c
min
s c s c
cr,N
Anchor size M10 M12 M16 M16L M20
c
min
[mm] 50 70 85 80
c
cr,N
[mm] 113 143 158 188 255
Note: If more than 3 edge distances are smaller than c
cr,N
, please contact your Hilti technical service.
ef
N , A
h 6
s
5 . 0 f - Limits: s
min
s s s s
cr,N
Anchor size M10 M12 M16 M16L M20
s
min
[mm] 50 60 70 80
s
cr,N
[mm] 225 285 315 375 510
HVZ adhesive anchor
Issue 2005 187
3
N
Rd,s
: Steel design tensile resistance
Anchor size M10 M12 M16 M16L M20
N
Rd,s
1)
[kN] 23.3 34.0 60.0 121.3
1)
The design value is calculated using N
Rd,s
= N
Rk,s
/
Ms,N
, where the partial safety factor,
Ms,N ,
is 1.5.
N
Rd
: System design tensile resistance
N
Rd
= lower of N
Rd,c
and N
Rd,s
Combined loading: Only if tensile load and shear load applied (See page 31 and section 4 Examples).
Detailed design method Hilti CC
SHEAR
The design shear resistance of a single
anchor is the lower of,
V
Rd,c
: concrete edge resistance
V
Rd,s
: steel resistance Note: If the conditions shown for h and c
2
cannot be
observed, please contact your Hilti sales representative.
V
Rd,c
: Concrete edge design resistance
The lowest concrete edge resistance must be calculated. All near edges must be checked, (not only the edge in
the direction of shear). The direction of shear is accounted by the factor f
,V.
V , AR V , V , B
0
c , Rd c , Rd
f f f V V

V
0
Rd,c
: Concrete edge design resistance
- Concrete compressive strength f
ck,cube(150)
= 25 N/mm
2
- at a minimum edge distance
min
c
V
c
s
rec,c/s
c

>
1
.
5
c
2
c

>
1
.
5
c
2
h
>
1
.
5
c
(The Hilti CC-Method is a simplified Version of ETAG Annex C)
HVZ adhesive anchor
188 Issue 2005
Anchor size M10 M12 M16 M16L M20
V
0
Rd,c
1)
[kN] non-cracked concrete 3.5 6.4 9.6 9.9 10.3
V
0
Rd,c
1)
[kN] cracked concrete
2.5 4.6 6.9 7.1 7.4
c
min
[mm] min. edge distance 50 70 85 80
1)
The design value of the ultimate state in shear is calculated from the characteristic anchor shear resistance, V
Rk,c,
divided by
V
Rd,c
= V
Rk,c
/
Mc,V
, where the partial safety factor,
Mc,V
, is 1.5.
f
B,V
: Influence of concrete strength
Concrete strength
designation
(ENV 206)
Cylinder compressive
strength
f
ck,cyl
[N/mm]
Cube compressive
strength
f
ck,cube
[N/mm]
f
B,V
C20/25 20 25 1
C25/30 25 30 1.1
C30/37 30 37 1.22
C35/45 35 45 1.34
C40/50 40 50 1.41
C45/55 45 55 1.48
C50/60 50 60 1.55
Concrete cylinder:
height 30cm, 15cm
diameter
Concrete cube:
side length 15cm
Concrete test specimen geometry
f
,V
: Influence of shear load direction
Angle []
f
,V
0 to 55 1
60 1.1
70 1.2
80 1.5
90 to 180 2
Formulae:
1 f
V ,

sin 5 . 0 cos
1
f
V ,
2 f
V ,

for 0 s s 55
for 55 < s 90
for 90 < s 180
f
AR,V
: Influence of edge distance and spacing
Formula for single-anchor fastening
Influenced only by edge
min min
V , AR
c
c
c
c
f
Formula for a two-anchor fastening valid
for s < 3c
min min
V , AR
c
c
c 6
s c 3
f
-

General formula for n-anchor fastening (edge plus n-1 spacing)


only valid where s
1
to s
n-1
are all < 3c and c
2
> 1.5c
min min
1 n 2 1
V , AR
c
c
nc 3
s ... s s c 3
f
- - - -

-
25
f
f
cube ck,
V B,

Limits: 25 N/mm
2
s f
ck,cube
s 60 N/mm
2
results
tabulated
below
V ... applied shear force

c
c
s
s
s
2,2
1
2
3
n-1
s
c
2,1
h >1,5 c
Note: It is assumed that only the row of anchors closest to
the free concrete edge carries the centric shear load
HVZ adhesive anchor
Issue 2005 189
3
f
AR.V
c/c
min
1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0
Single anchor with
edge influence
1.00 1.31 1.66 2.02 2.41 2.83 3.26 3.72 4.19 4.69 5.20 5.72 6.27 6.83 7.41 8.00
s/c
min
1.0 0.67 0.84 1.03 1.22 1.43 1.65 1.88 2.12 2.36 2.62 2.89 3.16 3.44 3.73 4.03 4.33
1.5 0.75 0.93 1.12 1.33 1.54 1.77 2.00 2.25 2.50 2.76 3.03 3.31 3.60 3.89 4.19 4.50
2.0 0.83 1.02 1.22 1.43 1.65 1.89 2.13 2.38 2.63 2.90 3.18 3.46 3.75 4.05 4.35 4.67
2.5 0.92 1.11 1.32 1.54 1.77 2.00 2.25 2.50 2.77 3.04 3.32 3.61 3.90 4.21 4.52 4.83
3.0 1.00 1.20 1.42 1.64 1.88 2.12 2.37 2.63 2.90 3.18 3.46 3.76 4.06 4.36 4.68 5.00
3.5 1.30 1.52 1.75 1.99 2.24 2.50 2.76 3.04 3.32 3.61 3.91 4.21 4.52 4.84 5.17
4.0 1.62 1.86 2.10 2.36 2.62 2.89 3.17 3.46 3.75 4.05 4.36 4.68 5.00 5.33
4.5 1.96 2.21 2.47 2.74 3.02 3.31 3.60 3.90 4.20 4.52 4.84 5.17 5.50
5.0 2.33 2.59 2.87 3.15 3.44 3.74 4.04 4.35 4.67 5.00 5.33 5.67
5.5 2.71 2.99 3.28 3.57 3.88 4.19 4.50 4.82 5.15 5.49 5.83
6.0 2.83 3.11 3.41 3.71 4.02 4.33 4.65 4.98 5.31 5.65 6.00
6.5 3.24 3.54 3.84 4.16 4.47 4.80 5.13 5.47 5.82 6.17
7.0 3.67 3.98 4.29 4.62 4.95 5.29 5.63 5.98 6.33
7.5 4.11 4.43 4.76 5.10 5.44 5.79 6.14 6.50
8.0 4.57 4.91 5.25 5.59 5.95 6.30 6.67
8.5 5.05 5.40 5.75 6.10 6.47 6.83
9.0 5.20 5.55 5.90 6.26 6.63 7.00
9.5 5.69 6.05 6.42 6.79 7.17
10.0 6.21 6.58 6.95 7.33
10.5 6.74 7.12 7.50
11.0 7.28 7.67
11.5 7.83
12.0 8.00
V
Rd,s
: Steel design shear resistance
Anchor size M10 M12 M16 M16L M20
V
Rd,s
1)
[kN]
HAS-(E-)TZ 14.4 21.6 40.8 70.4
V
Rd,s
1)
[kN
HAS-(E-)RTZ, HAS-(E-)HCR 16.0 24.0 44.8 78.4
1)
The design shear resistance is calculated using V
Rd,s
= V
Rk,s
/
Ms,V
. The values for the stressed
cross section A
s
and the nominal tensile strength of steel, f
uk
, are given in the table Anchor mechanical properties and geometry. The
partial safety factor,
Ms,V
is 1.25.
V
Rd
: System design shear resistance
V
Rd
: System shear design resistance
V
Rd
= lower of V
Rd,c
and V
Rd,s
Combined loading: Only if tensile load and shear load applied (See page 31 and section 4 Examples).
These results are for a two-.
Anchor fastening.
For fastening made with more
than 2 anchors, use the
general formulae for n
anchors.

Você também pode gostar