Group 2 MCR Series, 60 Hz Only
VA 120 250 500 750 1000* 1500* 2000* 3000* 5000* 7500** 10000** 15000** Catalog Number 63-23-112-4 63-23-125-4 63-23-150-8 63-23-175-8 63-23-210-8 63-23-215-8 63-23-220-8 63-23-230-8 63-23-250-8 63-28-275-8 63-28-310-8 63-28-315-8 Voltage Input 120, 208, 240, 480 120, 208, 240, 480 120, 208, 240, 480 120, 208, 240, 480 120, 208, 240, 480 120, 208, 240, 480 120, 208, 240, 480 120, 208, 240, 480 120, 208, 240, 480 208, 240, 480 208, 240, 480 208, 240, 480
Voltage Output 120 120 120, 208, 240 120, 208, 240 120, 208, 240 120, 208, 240 120, 208, 240 120, 208, 240 120, 208, 240 120, 208, 240 120, 208, 240 120, 208, 240
Height (inch) 9 10 13 14 17 17 18 19 28 27 28 28
Width (inch) 4 6 9 9 9 13 13 13 13 26 26 38
Depth (inch) 5 8 7 7 7 9 9 9 9 9 9 10
Design Style 1 1 1 1 1 1 1 1 1 2 2 3
Elec Conn D D E E E E E E E F F F
* Canadian option: cULus certified units must be ordered by changing -8 (UL only) to -C8. ** UL Listed Only. Use Group 3 for cULus.
36
Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com.
1
Elec Conn B B B B A A A A
Specifications
Parameter Condition Input Voltage Current
1
Value +10% to -20% of nominal +20% to -35% of nominal Iin (VA/.89)/(Vin x 80%) 50 Hz or 60 Hz depending on model
Continuous at full load (lower input voltage possible at lighter load) For temporary surge or sags at Full Load & 80% of nominal input voltage See Operating Characteristics section for details. Output
Frequency
Vin >80% and <110% of nominal At Nominal Input Voltage At full load within input range Common Mode Transverse Mode General At Full Load Humidity <95% non-condensing Humidity <95% non-condensing Full Resistive Noise 60 Hz Models 50 Hz Models See General Information section for details
5% for 50 Hz units, 3% for 60 Hz units Current limited at 1.65 times rated current 3% total RMS content 120 dB 60 dB Up to 92% -20 to +85C -20 to 50C 35 dBA to 65 dBA UL1012, CSA evaluated by UL CE (EMC & LVD) 10 + 2 Years
Notes: 1 - Consult user manual for fuse sizing. 2 - It is recommended that the unit run at a minimum of 40-50% load.
Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com.
37
1
Electrical Connections
Primary Voltage 208 240 480 600 Secondary Voltage 120 208 240
Interconnect H1 to H4 H2 to H5 H1 to H4 H3 to H6 H3 to H4 H3 to H4 Interconnect
Connect Lines To H1 & H5 H1 & H6 H1 & H6 H1 & H7 Connect Lines To X1 & X2 or X3 & X2 X4 & X5 X1 & X3 Primary Voltage 600 Secondary Voltage 120 208 240 Interconnect Interconnect Connect Lines To H1 & H2 Connect Lines To X1 & X2 or X3 & X2 X4 & X5 X1 & X3
Primary Voltage 110-120 220-240 380-415 Secondary Voltage 110 120 220 240
Interconnect H1 to H3 H2 to H4 H2 to H3 H2 to H3 Interconnect
Connect Lines To H1 & H4 H1 & H4 H1 & H5 Connect Lines To X1 & X2 or X3 & X2 X4 & X2 or X5 & X2 X1 & X3 X4 & X5
MCR 60 Hz 500015000 VA
MCR 60 Hz 5003000 VA
MCR 50 Hz 1205000 VA
C1
C2
Primary Voltage 220-240 380-415 Secondary Voltage 110 120 220 240
Interconnect H1 to H3 H2 to H5 H2 to H3 Interconnect
Connect Lines To H1 & H5 H1 & H4 Connect Lines To X1 & X2 or X2 & X3 X4 & X2 or X5 & X2 X1 & X3 X4 & X5
Primary Voltage 220-240 380-415 Secondary Voltage 110 120 220 240
Interconnect H2 to H3 H2 to H3 Interconnect
Connect Lines To H1 & H4 H1 & H5 Connect Lines To X1 & X2 or X3 & X2 X4 & X2 or X5 & X2 X1 & X3 X4 & X5
Interconnect
Interconnect
MCR 60 Hz 120250 VA
MCR 50 Hz 7500 VA
MCR 50 Hz 1000015000 VA
38
Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com.
1
G
Primary Voltage 120 208 240 480 Secondary Voltage 120 208 240
Interconnect
Connect Lines To H1 & H2 H1 & H3 H1 & H4 H1 & H5 Primary Voltage 208 240 480 Secondary Voltage 120 208 240 Interconnect Interconnect Connect Lines To H2 & H3 H2 & H4 H1 & H4 Connect Lines To X1 & X2 or X3 & X2 X4 & X5 X1 & X3 Primary Voltage 120 240 480 Secondary Voltage 120 Interconnect H1 to H3 to H5 to H7 H2 to H4 to H6 to H8 H2 to H3 H6 to H7 H1 to H5 H4 to H8 H2 to H3 H4 to H5 H6 to H7 Interconnect Connect Lines To H1 & H2 H1 & H4 H1 & H8 Connect Lines To X1 & X2
Interconnect
MCR 60 Hz 5005000 VA
H2 to H3 H7 to H8 H1 to H6 H5 to H10 H2 to H3 H5 to H6 H7 to H8 Interconnect
CVS 60 Hz 5005000 VA
Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com.