Escolar Documentos
Profissional Documentos
Cultura Documentos
InteliNano NT AMF
Typical wiring diagram
LOAD GCB DIESEL / GASOLINE ENGINE GENERATOR MCB
Dimensions
Case dimensions: 118mm x108mm x 40mm Panel Cutout: 96mm x 96mm
L1
ECU
L2 L3 N
GENERATOR VOLTAGE MEASUREMENT T16 = Neutral T17 = Phase 1 T18 = Phase 2 T19 = Phase 3
MAINS VOLTAGE MEASUREMENT T20 = Neutral T21 = Phase 1 T22 = Phase 2 T23 = Phase 3
Fuel Solenoid Fuel Level Analog Coolant Temperature Analog Oil Pressure Analog
CAN INTERFACE
L COM H
Battery
+
Sarter
USB interface
CAN L COM H
D+
USB COM Remote Start And Load Emergency Stop Starter Fuel Solenoid MCB GCB Alarm Ready To Load Battery D+ Battery +
PC
INTPUT TERMINALS T10 = COM for analog inputs T11 = binary input T12 = binary input T13 = binary/analog input Low Fuel Level T14 = binary/analog input Coolan Temperature T15 = binary/analog input Oil Pressure
OUTPUT TERMINALS T04 = binary output Starter (6A) T05 = binary output - Fuel Solenoid (6A) T06 = binary output (500 mA) T07 = binary input/output (500 mA) T08 = binary output (500 mA) T09 = binary output (500 mA)
If you have already created your own init screen then press and hold Stop button and then briefly press , the custom init screen will appear, keep holding the Stop
Normally Open Contact - input button Normally Closed Contact input button
InteliNano-NT AMF, SW version 1.2, ComAp June 2012 IN-NT-AMF-1.2-Fast User Guid.pdf
ComAp, spol s.r.o Kundratka 2359/17 180 00, Praha 8 Czech Republic
Setpoints
Use and buttons to move or change value. Start button to select setpoint or confirm changes and Stop button to go back. Basic settings Setpoint Setpoint name code B01 Nominal Voltage Ph-N B02 Nominal Voltage Ph-Ph B03 Nominal Frequency B04 B05 B06 B07 B08 Connection Type Units Format AMF Function Zero Power Mode Delay Light Tower Mode Generator protections Setpoint code G01 G02 G03 G04 Setpoint name Generator Overvoltage Shutdown Generator Undervoltage Shutdown Generator Overfrequency Shutdown Generator Underfrequency Shutdown G02 200 % 0 - G01 % G04 130 % 0 G03 % Setpoint code A01 A02 A03 A04 A05 A06 Setpoint code E01 E02 E03 E04 E05 E06 E07 E08 E09 E10 Engine parameters and protections Setpoint name Prestart Time Maximum Cranking Time Cooling Time Oil Pressure Shutdown Coolant Temperature Shutdown Battery Undervoltage Warning Maintenance Oil Pressure Starter Disengagement Choke Time Minimal Stabilization Time AMF(Auto Mains Failure) settings Setpoint name Emergency Start Delay Mains Return Delay Mains Overvoltage Mains Undervoltage Mains Overfrequency Mains Underfrequency 0 600 s 1 3600 s A04 150 % 50 A03 A06 150 % 50 A05 % 0-600 s 0-60 s 0-3600 s 0-10 Bar 0 -150 C 8 40 V 0 10000 h Disable (1), Enable (2) 0 3600 s 1 300 s
80 480 V 80 600 V 50 Hz (1), 60 Hz (2) Mono Phase (1), SplitPhase (2), 3Ph3Wire (3), 3Ph4Wire (4), Autodetect (5) Metric unit format (1), US unit format (2) Disable (1), Enable (2) 0-360 min Disable (1), Enable (2)
To apply all changes return to the main setup menu and restart the controller by pressing the Stop button.
ECU
For ECU configuration use PC software NanoEdit. For more details see InteliNano AMF Reference Guide.
Technical data
Power supply range Power supply drop-out immunity Power consumption Zero Power Mode consumption 6-36 VDC 100 ms 35 295 mA 52 - 344 A Operating temperature Operating humidity Protection degree (front panel) Storage temperature Binary outputs (up to 6) Low current outputs (4) High current output (2) Total output current Analog inputs (up to 3) Galvanic insulation Electrical range Resolution Precision Binary inputs (up to 6) Input resistance Closed contact voltage Open contact voltage Generator/Mains measurements Measurement input Measurement type Voltage range Max. measured voltage Voltage accuracy Frequency range Frequency accuracy -20... 70 C 95 % non-condensing (IEC/EN 60068-2-30) IP65 with GASKET 4x405 only IP50 without gasket -30... 80 C 1,5 k <2 V >3,5 V
Charging alternator preexcitation circuit Excitation current 100 mA Charging fail threshold 80 % InteliNano-NT AMF, SW version 1.2, ComAp June 2012 IN-NT-AMF-1.2-Fast User Guid.pdf
3ph generator voltage, 3ph mains voltage True RMS 480 V Ph-Ph (277 V Ph-N) 340 V Ph-N 1% 40 70 Hz 1%