Escolar Documentos
Profissional Documentos
Cultura Documentos
MANUFACTURING COMPANY
2012 PRODUCT CATALOG
FREEDOM OF FORM IN ARCHITECTURAL METAL SYSTEMS Roofs Walls Soffits Mansards Ceilings Fascia Facades Equipment Screens Restoration Berridge exclusive on-site fabrication technology provides: Custom Contoured Panels Curved Barrel Vault Panels Tapered Panels Compound Curved Panels Long Length Panels
(800) 669-0009
www.berridge.com
10
11
12-13
tee-panel
12
curved tee-panel
14
cee-lock
16
zee-lock
17
curved zee-lock
18
batten seam
18
bermuda panel
19
spanish tile
19
s-tile
32
victorian shingle
20
classic shingle
21
rustic shake
22
fish scale
23
FLUTED FASCIA
24
hr-16
26
vee-panel
27
fw-12
28
l-panel
29
B-6 PANEL
30
FLUSH SEAM
31
THIN LINE
31
S-DECK
32
DEEP DECK
33
M-PANEL
R-PANEL
DOUBLE RIB
coating line, slitting lines, cut-to-length lines, roll formers, mechanical and hydraulic press-brakes, punch presses, stamping and bending fixtures, and a variety of special dies. This complete line of in-house equipment not only produces top-of-the-line products at the most competitive prices but assures prompt delivery as well.
EQUIPMENT
Berridges modern, high-production equipment provides customers with low cost, top-quality products. Highly specialized manufacturing equipment converts large, bare Galvalume and galvanized steel coils into pretreated, prefinished, high quality fabricated architectural sheet metal products. Berridge equipment includes a continuous coil
Berridge SS-1421 High Seam Tee-Panel Portable Roll Former can form straight and curved roof panels in continuous lengths to eliminate panel end splices. Machine also curves factory formed snap-on seam caps.
Berridge CL-21 Cee-Lock Portable Roll Former forms straight standing seam roof panels in continuous lengths to eliminate panel end splices. Machine also inserts patented vinyl weatherseal in female snap-lock leg.
Above: The unique patented Berridge Vinyl WeatherSeal, which is used on all standing seam and Bermuda Panel systems, provides extra watertight integrity. Right: Curved Panel Applications are possible with Berridge Portable Roll-Formers. Curved standing seam roof panels are curved at the job site.
Solar Reflectivity
67.10 29.66 29.30 17.20 30.30 39.71 30.05 34.95 29.64 33.03 29.57 45.24 28.20 38.54 29.08 28.20 30.92 32.90 28.70 31.39 75.93 51.72 34.42 33.61 29.90 60.00 34.81 28.10 31.66 52.45 37.88 74.00 67.00
Emissivity
0.90 0.86 0.85 0.83 0.86 0.86 0.85 0.85 0.87 0.85 0.87 0.87 0.91 0.84 0.85 0.90 0.83 0.90 0.91 0.85 0.84 0.83 0.86 0.80 0.90 0.84 0.84 0.89 0.83 0.87 0.84 0.14 0.06
SRI
82 30 29 12 31 43 30 36 30 34 30 51 30 41 29 30 30 35 30 32 93 58 36 32 32 70 36 29 31 61 40 67 55 *These values are based on data from the Steel Recycling Institute (November, 2009) and may vary.
RECYCLED CONTENT OF BERRIDGE METAL Berridge metal products have a high recycled content and are 100% recyclable at the end of their lifespan. Using building products that incorporate recycled materials helps reduce the impacts resulting from the extraction and processing of natural resources. Post-consumer* steel recycled content 25.5% Pre-consumer* steel recycled content 6.8% TOTAL RECYCLED CONTENT 32.3%
LEED V3 2009 COMPLIANCE In addition to meeting LEED criteria for SS Credit 7.2: Heat Island Effect and for MR Credit 4: Recycled Content, using Berridge metal products can contribute to other LEED points. Reference the Technical Bulletins section at www.berridge.com for complete information on Berridges compliance with LEED V3 2009. While every effort has been made to provide accurate information, applicants for LEED Certification should verify compliance with a LEED expert. For more information on LEED 2009 certification visit www.usgbc.org.
SRI Values are provided by Berridges paint supplier and may vary slightly. Reference www.berridge.com for the most up-to-date information on Berridge SRI Values.
STANDARD COLORS
Due to limitations in the printing process, please request actual color chips for accurate color viewing.
BUCKSKIN
PARCHMENT
ALMOND
AGED BRONZE
SHASTA WHITE
FOREST GREEN
PATINA GREEN
SIERRA TAN
MEDIUM BRONZE
CHARCOAL GREY
HEMLOCK GREEN
BRISTOL BLUE
TERRA-COTTA
DARK BRONZE
ZINC GREY
HARTFORD GREEN
ROYAL BLUE
COLONIAL RED
COPPER BROWN
MATTE BLACK
TEAL GREEN
DEEP RED
PREMIUM COLORS
Berridge premium colors require a nominal surcharge.
Berridge metallic colors are premium finishes which require a nominal surcharge. Due to limitations in the printing process, please request actual color chips for accurate color viewing.
NATURAL WHITE
AWARD BLUE
CHAMPAGNE
COPPER-COTETM
ANTIQUE COPPER-COTE
ACRYLIC-COATED GALVALUME
ZINC-COTETM
LEAD-COTETM
PREWEATHERED GALVALUME
All colors except Award Blue comply with LEED v3 & Energy Star requirements for steep slope roofs greater than 2:12. Almond & Natural White comply with LEED v3 requirements for low slope roofs, 2:12 or less. Natural White also complies with Energy Star requirements for low slope roofs, 2:12 or less. 5 2012 Berridge Manufacturing Company 800-669-0009 www.berridge.com
All information subject to change without notice.
Berridge owns and operates its own modern continuous coil coating line in San Antonio, Texas, painting both 48 and 42 wide Galvalume master coils.
COATING SYSTEM
ACRYLIC-COATED GALVALUME
Acrylic-Coated Galvalume (ACG) is a coated sheet product that combines the corrosion resistance of GALVALUME steel sheet with a clear, acrylic coating that is applied over GALVALUME substrate. The surface treatment is essentially invisible but it provides excellent characteristics to enhance the performance and applicability of GALVALUME steel sheet. These enhancements include: good rollformability without the need for oils, excellent transit and field-storage performance without staining, dramatic decrease in finger printing or foot printing during installation and long term surface brightness when exposed to the environment. It is applied at the mill by roll-coating a uniform, thin film of a water-base acrylic solution onto both surfaces of the sheet.
Protective Strippable Film (painted material only) 0.75 0.05 mil Kynar500 Hylar5000 top coat 0.20 0.05 mil primer coat 24 gauge or 22 gauge Galvalume substrate 0.35 0.05 mil total dry film thickness for primer coat (non-metallics only) & beige urethane backer coat (all colors) Notes: 1. Special colors and finishes are available. Please consult Berridge for pricing and delivery. 2. Berridge metallic finishes are premium finishes and require a nominal surcharge. 3. Galvalume is a registered trademark of BIEC International, Inc. 4. Kynar 500 is a registered trademark of Arkema, Inc. 5. Hylar 5000TM is a registered trademark of Solvay Solexis.
MIAMI DADE
UL 90
UL 1897
UL 790
UL 263
FL PROD APP
MIAMI DADE
UL ASTM ASTM ASTM ASTM ASTM ASTM ASTM FM 2218 E 1592 E 330 E 2140 E 1646 E 1680 E 331 E 283 4471
UL 90 UL 1897
UL 790 UL 263
FL PROD APP
UL ASTM ASTM ASTM ASTM ASTM ASTM ASTM FM 2218 E 1592 E 330 E 2140 E 1646 E 1680 E 331 E 283 4471
MIAMI DADE
For actual test results, technical questions, fastener types, fastener spacing, or job-specific engineering, please contact Berridges Technical Department at (800) 669-0009. Updates and additional testing are added on a continual basis. Consult Technical Dept. for the latest updates.
UL 90 - Uplift Tests of Roof System UL 1897 - Uplift Tests of Roof System UL 790 - Fire Tests of Roof System UL 263 - Fire Tests of Construction and Materials UL 2218 - Impact Resistance of Prepared Roof Covering Materials ASTM E-1592 - Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference ASTM E-330 - Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference ASTM E-2140 - Water Penetration of Metal Roof Panel Systems by Static Water Pressure Head ASTM E-1646 - Water Penetration of Exterior Metal Roof Panel Systems by Uniform Static Air Pressure Difference ASTM E-1680 - Rate of Air Leakage Through Exterior Metal Roof Panel Systems ASTM E-331 - Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference ASTM E-283 - Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen FM 4471 - This standard states Approval requirements for Class 1 Panel Roofs. A Class 1 Panel Roof meets the criteria of this standard for fire, wind, foot traffic & hail damage resistance. Florida Product Approval - Standard of practice for product evaluations and consistency of enforcement for the state of Florida. Miami-Dade Approval - Established with its main goal to allow new and innovated ideas to be developed into useful, practical, lasting and safe products for use in High Velocity Hurricane Zones.
Berridge Tee-Panel
Metal Standing Seam with exclusive patented vinyl weatherseal as an integral part of Snap-On Seam. For residential or commercial construction with solid sheathing.
Available in 24 gauge steel Concealed fasteners Extruded vinyl weatherseal as integral part of Snap-on seam cap UL 580 tested UL 90 wind uplift & UL fire resistance listed ASTM air & water resistance tested Florida Product Approval May be site-formed in continuous lengths with Berridge SS-14 portable roll former 1 (25 mm) Convex (min 4) & concave (min 6) curving with Berridge SS-14 portable roll former
Snap-On Seam
Tee-Panel
See www.berridge.com for Details and Specifications Vinyl Weatherseal: US Patent No. 4641475
Available in 24 gauge steel Concealed fasteners Extruded vinyl weatherseal as integral part of Snap-on seam cap UL 580 tested UL 90 wind uplift & UL fire resistance listed ASTM air & water resistance tested Florida Product Approval Site-formed & curved with Berridge SS-14 portable roll former (Use 1 (25 mm) SL-24 for tapered & SL-1 for compound curved panels)
Snap-On Seam
Tee-Panel
See www.berridge.com for Details and Specifications Vinyl Weatherseal: US Patent No. 4641475
Available in 24 gauge steel Concealed fasteners Extruded vinyl weatherseal as integral part of Snap-on seam cap UL 580 tested UL 90 wind uplift & UL fire resistance listed ASTM air & water resistance tested Florida Product Approval May be site-formed in continuous lengths with Berridge SS-1421 portable roll former Consult Berridge for minimum radius.
1 or 1 (25 mm or 38 mm)
Snap-On Seam
Tee-Panel
See www.berridge.com for Details and Specifications Vinyl Weatherseal: US Patent No. 4641475
10
Available in 24 & 22-gauge steel Easy to install, integral snap-lock seam UL 90 wind uplift & UL fire resistance listed Concealed fasteners Patented vinyl weatherseal (optional) Striated profile is available ASTM air & water resistance tested ASTM E-1592 tested 1 UL 1897 tested (38 mm) Miami-Dade approved Florida Product Approval May be site-formed in continuous lengths with Berridge CL-21 portable roll former
Cee-Lock Panel
See www.berridge.com for Details and Specifications Vinyl Weatherseal (Optional) is required for Watertight Warranties. Cee-Lock Clip or Continuous Cee-Rib
11
Berridge Zee-Lock
Architectural/Structural standing seam roof system for use over open purlin framing or solid sheathing. Straight or curved applications.
Available in 24 & 22 gauge steel Extruded patented* vinyl weatherseal Mechanically seamed sidelap 2 high standing seam sidelap UL 90 wind uplift & UL fire resistance listed ASTM air & water resistance tested ASTM E-1592 & UL 580/UL 1897 tested ASTM E-2140 tested Corps of Engineers CEGS 07416 approved Miami-Dade Approved Florida Product Approval Optional striated profile available Continuous lengths when site-formed with SP-21 portable roll-former Site-curved with ZC-21 curving machine
Berridge Zee-Lock Single Lock can be curved to a minimum radius of 20 using the Berridge ZC-21 Curver machine. Curving of the panel to be done on-site.
11/16
16 406 mm 1 3/16
2 51 mm
Optional Extruded Vinyl Weatherseal (*US Patent No. 5134825) Note: Vinyl Weatherseal required for open framing and curved applications as well as for Watertight Warranties.
The Berridge Zee-Lock Seamer locks the sidelap seam in a single pass. Use continuous ZeeRib with vinyl for best performance.
ZEE-LOCK SECTION PROPERTIES BASED ON 24 GA 40 K.S.I. ZEE-LOCK Positive Bending Negative Bending IX (in4/ft) 0.1525 0.1031 MA (ft.lbs/ft) 184.65 161.33 VA (lbs/ft) 990 990
NOTES: Zee-Lock Panel with continuous 24 GA Zee-Rib. Values based on 1996 edition of AISI and good engineering practice.
12
11/16
16 406 mm 1 3/16
2 51 mm
Available in 24 gauge steel Mechanically double-locked sidelap 2 high standing seam sidelap UL 90 wind uplift & UL fire resistance listed FMRC Approved & 1-120 rated ASTM air & water resistance tested ASTM E-1592 & UL 580/UL 1897 tested ASTM E-2140 tested Florida Product Approval Miami-Dade Approval Optional striated profile available Continuous lengths when site-formed with SP-21 portable roll-former
The 180-degree mechanically seamed Zee-Lock seam is not available with vinyl weatherseal. Continuous Zee-Rib
The Berridge Zee-Lock Double-Lock Seamer double locks the sidelap seam in a single pass. Not available for use with vinyl weatherseal.
ZEE-LOCK SECTION PROPERTIES BASED ON 24 GA 40 K.S.I. ZEE-LOCK Positive Bending Negative Bending IX (in4/ft) 0.1525 0.1031 MA (ft.lbs/ft) 184.65 161.33 VA (lbs/ft) 990 990
NOTES: Zee-Lock Panel with continuous 24 GA Zee-Rib. Values based on 1996 edition of AISI and good engineering practice.
13
Available in 24 gauge steel Spans over open purlins Concealed fasteners UL 90 & UL fire resistance listed Florida Product Approval May be site-formed in continuous lengths with Berridge BP-21 portable roll-former
16 Coverage (406 mm)
1 (45 mm) 2
14
15
Available in 24 gauge steel Stronger and lighter than clay tiles May be installed over open framework Available in all standard Berridge Kynar 500 or Hylar 5000TM finishes Florida Product Approval UL 580/UL 1897 tested Concealed fasteners
2 (51 mm)
1 (38 mm)
Eave Closure
16
Berridge S-Tile
Prefinished metal S-Tile panels with a clean, crisp simulated tile appearance.
Available in 24 gauge steel Light weight: only 1.2 pounds per square foot Available in all standard Berridge Kynar 500 or Hylar 5000TM finishes Exposed fasteners
Miami-Dade approved
Florida Product Approval UL 580/UL 1897 tested Continuous length eave-to-ridge panels up to 40 long for fast installation without panel endlaps
3 min - 40 max
14 (350 mm) 14 (350 mm) 14 (350 mm)
17
METAL SHINGLES
18
METAL SHINGLES
19
24 gauge with stucco embossed texture Available in 22 gauge Concealed fasteners Multi-purpose wall panel May be used horizontally or vertically May be used for soffit applications Wide rib appearance Interlocks with HR-16 wall panel Factory formed to 40 max ASTM E-1592 tested Florida Product Approval Consult Berridge for smooth finish availability
Berridge HR-16
Prefinished horizontal or vertical wall panel. Versatile and maintenance-free.
24 gauge smooth Available in 22 gauge Concealed fasteners May be used horizontally or vertically Narrow-rib appearance Multi-purpose panel Florida Product Approval Miami-Dade Approved ASTM E-1592 tested Factory formed to 40 max
16 Coverage (406 mm) 4 (102 mm) (22 mm) 1 1/ 8 (29 mm) 1 5/ 8 (41 mm)
7 / 8
Berridge HR-16 can be installed horizontally or vertically. All information subject to change without notice.
21
Berridge Vee-Panel
Wall, soffit and facade system Versatile and maintenance free Prefinished metal wall panels for open spans
Berridge Vee-Panel can be installed vertically on curved fascia applications.
24 gauge standard Available in 22 gauge Concealed fasteners Vee-Groove appearance Use horizontally for soffit Use vertically for facade or wall Panel may be vented Open framing or solid deck applications Optional wood grain embossing
(10 mm)
3/8
Vented Vee-Panel Notes: Panel provides 6.08 square inches of Net Free Vent Area (NFVA) per square foot of panel (6.46 square inches per linear foot). Berridge Manufacturing Company does not recommend vented products in applications subject to aggressive atmospheres, marine environments or high humidity due to the corrosive nature of these environments on raw edges of steel.
See www.berridge.com for Details and Specifications
22
24 gauge standard Available in 22 gauge Concealed fasteners Flush appearance Multi-purpose panel Use horizontally for soffit Use vertically for facade or wall Available with or without grooves Florida Product Approval Miami-Dade Approved ASTM E-1592 Optional stucco embossing
Vented FW-12 Notes: Panel provides 7.79 square inches of Net Free Vent Area (NFVA) per square foot of panel (7.79 square inches per linear foot). Berridge Manufacturing Company does not recommend vented products in applications subject to aggressive atmospheres, marine environments or high humidity due to the corrosive nature of these environments on raw edges of steel.
See www.berridge.com for Details and Specifications
Berridge FW-12 can be vented for soffit applications.
23
Berridge L-Panel
Versatile, maintenance-free, prefinished metal liner or soffit panels for open spans.
24 gauge standard Consult BMC on 22 gauge availability Concealed fasteners Flush appearance Use vertically for fascia applications Available with or without grooves Panel may be vented Florida Product Approval Miami-Dade Approved ASTM E-1592 May be site-formed using Berridge FP-16 portable roll former
Berridge L-Panel is an economical and versatile panel for fascia, soffit, liner, and celing applications. Available with 2 grooves, 1 groove or no grooves as shown above.
Berridge L-Panel is a great soffit panel and can be site-formed with the FP-16 portable roll former.
Vented L-Panel Notes: Panel provides 5.35 square inches of Net Free Vent Area (NFVA) per square foot of panel (5.19 square inches per linear foot). Berridge Manufacturing Company does not recommend this product in applications subject to aggressive atmospheres, marine environments or high humidity due to the corrosive nature of these environments on raw edges of steel.
Berridge L-Panel can be vented for soffit applications.
24
24 gauge steel Concealed fasteners Use vertically for fascia, facade or siding Self-venting Spans over open framework or solid sheathing Florida Product Approval
Berridge B-6 Panel is a good option for fascia and soffit applications and provides a sleek, corrugated appearance.
Berridge B-6 Panel is a great option for interior ceiling and wall applications.
25
Berridge Flush Seam is a multipurpose wall, soffit and liner panel and can also be used in interior ceiling applications as shown above.
24 gauge steel Spans over open framework or solid sheathing Concealed fasteners Flat appearance Stucco embossed texture Multi-purpose panel Use horizontally for soffit Use vertically for facade or wall Self-venting Optional wood grain texture Florida Product Approval
Berridge Flush Seam can be used vertically on curved wall applications. Panel does not curve.
26
Berridge Thin-Line
Versatile, maintenance-free, prefinished metal fascia, facade, wall or soffit panels for open spans.
24 gauge steel Channel drain interlock Narrow, strong panel Smooth appearance Concealed fasteners Thin extruded appearance Use horizontally for soffit Use vertically for fascia or wall Optional wood grain or stucco embossed texture Florida Product Approval
Berridge Thin Line is a multipurpose wall,soffit, liner, ceiling and fascia panel.
3/8
See www.berridge.com for Details and Specifications 2012 Berridge Manufacturing Company 800-669-0009 www.berridge.com
All information subject to change without notice.
27
Berridge S-Deck
Corrugated structural metal sheathing. S-Deck may be curved for covered walkways, shelter covers, etc.
24 gauge standard Available in 22 gauge Vertical and horizontal applications 32 panels can be factory curved Minimum 5 radius for curved panels Florida Product Approval ASTM E-1592 tested
2 2/3 67 mm
2 2/3 67 mm
Curved S-Deck Notes: Curved S-Deck is available in 32 exposure panels only. Berridge recommends lapping two corrugations on panel side laps when using curved S-Deck. Exposure will be 29-1/3 with two laps or 32 with one lap.
See www.berridge.com for Details and Specifications
28
Berridge Deep-Deck
Prefinished corrugated 7.2 roof or wall panel for use on open framing or solid sheathing.
24 gauge standard Available in 22 gauge Wide, economical 36 coverage Vertical & horizontal applications Structural properties Multi-use panel: roof, wall, deck Purlin bearing leg standard Florida Product Approval ASTM E-1592 tested
29
Berridge M-Panel
Prefinished or Acrylic Coated Galvalume, wall, soffit, fascia, mansard, liner or equipment screen panel
24 gauge standard Available in 22 gauge Wide, 3-foot coverage UL 90 approved Spans over open purlins Florida Product Approval
38 Overall Width (972 mm) See www.berridge.com for Details and Specifications
30
Berridge R-Panel
Prefinished or Acrylic Coated Galvalume, wall, soffit, fascia, mansard, liner or equipment screen panel
24 gauge standard Available in 22 gauge Wide, 3-foot coverage UL 90 approved Spans over open purlins Florida Product Approval UL 580/UL 1897 tested
24-gauge steel Wide, economical 24 coverage Residential or utility Traditional appearance Florida Product Approval
24 Coverage (610 mm)
(13 mm) 12 (305 mm) See www.berridge.com for Details and Specifications
31
10 Coverage (250 mm) (9 mm) See www.berridge.com for Details and Specifications
3/8
8 Coverage (203 mm) (5 mm) See www.berridge.com for Details and Specifications
3/16
32
24-gauge Berridge Spaceframe Components Sturdy 16-gauge galvanized steel posts Available in 42, 62, 82 & 102 heights Consult BMC for other fence heights 31 Berridge Kynar 500 Hylar 5000 Colors 20-Year Paint Finish Limited Warranty Permanent: will not rot, fade, crack or split Residential or commercial applications Level and sloped applications 100% recyclable materials Interlocking panels with concealed fasteners Choose from 5 Berridge 24-gauge panels: Vee-Panel, Flush Seam, Thin-Line, B-6, HR-16.
Berridge Spaceframe
24 GA Studs 3 1/2 X 1 1/2 Berridge Spaceframe Building System components are used for the construction of light-commercial and residential projects.
16 GA Cee-Channel 2 1/2 X 8
Thickness Depth
(in)
0.024 0.024
TORSIONAL PROPERTIES
J (in4)
24 GA Blocking 3 1/2 X 24
33
FRAMING MEMBERS
24-Gauge & 16-Gauge Components Hat Section Purlin 24-Gauge Framing Section 24-Gauge Channel Section 24-Gauge Furring Channel 24-Gauge High Purlin 16-Gauge Low Purlin 16-Gauge Angle 1 1/2 x 2 16-Gauge Channel 4 x 2 16-Gauge Channel & Zee Purlin 4 x 2 1/2 16-Gauge Channel 6 x 2 16-Gauge Channel & Zee Purlin 6 x 2 1/2 16-Gauge Channel 8 x 2 16-Gauge Channel & Zee Purlin 8 x 2 1/2 16-Gauge
1/2 1 3/8 2 3/8 2 1 3 1 5/8 3/4 2 5/8 2 1 1 3 3/8 1 1/4 3 5 1/16 2 1/8 1 1 5/8
Weight/LF
A(in2) (Full)
I (Effective) in T.I.C.
B.I.C.
0.65 lbs
.1900
.0665
.0679
1.61
1.77
1.01
.065 lbs
.1900
.0759
.0866
1.80
2.26
1.08
0.47 lbs
.1380
.0530
.0556
1.15
1.21
1.08
7/8
0.35 lbs
.1030
.0180
0.180
0.78
0.86
0.53
1.43 lbs
0.422
.151
5.74
2.71
1.51 0.56
0.61 1.31
1.70 lbs
2
0.501
1.22
17.7
3.76
2 4 3/4
1.97 lbs
0.557
1.42
18.4
3.84
2.10 lbs
2
0.621
3.15
30.6
3.45
2 6 3/4
2.41 lbs
0.677
3.61
31.8
3.20
2.50 lbs
2
0.737
6.43
45.0
2.36
2 8 3/4
2.82 lbs
0.797
7.09
47.7
2.36
Notes for 24 GA (0.60 mm) & 16 GA (1.52 mm) Shapes: 1. Values based on 2007 North American Specification for the Design of Cold-Formed Steel Structural members, with compression flange braced against lateral buckling. 2. Net section properties are used for resisting moment determination and allowable shear loads. 3. Minimum yield strength = 40 ksi for 24 gauge shapes and 50 ksi for 16 gauge shapes (Galvanized steel material).
4. E = 29,500 ksi. 5. Values are for upward and downward loads. 6. T.I.C. = Top in Compression 7. B.I.C. = Bottom in Compression
34
VANTAGE POINT: MORE THAN JUST A NEW ROOF ITS A WHOLE NEW LOOK!
Thermal & Mechanical Considerations
Insulation
The space between the old and new roof allows for low-cost, blanket insulation to greatly reduce heating and cooling costs.
Problem: Flat roofs can sometimes become problematic and unsightly with rooftop units, mechanical equipment, and pooling water.
BEFORE
A vinyl vapor barrier on the underside of the blanket insulation avoids condensation from the building penetrating insulation and reaching the framing system and roof panels.
Any existing and new mechanical equipment should be located at ground level to reduce penetrations. The new attic space can be vented with ridge vents or louvers.
Thermal Movement
AFTER
Solution: Berridge Vantage Point Retrofit Roof System provides a totally new design appearance, hides unsightly mechanical equipment, and offers watertight integrity.
Roof Plane
Berridge VANTAGE POINT reroofing system combines a new aesthetic look with simple mechanical attachment over existing flat, built-up roofs that will last for years to come. VANTAGE POINT is more than just a patch-up or a re-roof solution; it is a permanent new roof with a new higher profile which gives your old building a totally new look. The sloped, light-weight, self-supporting metal panels need no substrate, thus avoiding extra weight and cost. They provide a watertight standing seam that sheds water in contrast to dated, flat, built-up roofs which are subject to water pooling and subsequent leakage. Added insulation may be placed on the existing flat roof.
1 3
6 5
2 4 3/4 4 3/4 2 4 4
2
3/4
Cee-Channel 16 Gauge
Zee-Purlin 16 Gauge
Zee-Purlin 16 Gauge
1
1 1/4 3 5 1/16
1 5/8
ZEE-LOCK
The Berridge Zee-Lock architectural/structural standing seam roof systems provides superior aesthetic appearance and excellent performance.
Hat-Channel 24 Gauge
5 1 2 3 4
Single-Source Convenience
16 ga. Cee-Channel. Connect ea. end w/ (4) #12-14 self-drilling fasteners. 16 ga. Eave Strut. Connect to beam w/ (2) #12-14 self-drilling fasteners. 16 ga. Continuous 4 x 2-1/2 Zee-Purlin Roof Support. 16 ga. Continuous 4 x 2-1/2 Retrofit Zee-Purlin. 24 ga. Hat-Channel. Connect to beam w/ (2) #12-14 self-drilling fasteners ea flange. 16 ga. Open-Track x 1-0 Long. Anchor into wall. Connect to beam w/ (2) #12-14 self-drilling fasteners ea flange. 24 ga. 2 Bottom Flange Strapping at Purlin mid-span. Connect to purlin w/ (1) #12-14 self-drilling fastener.
The installer orders all necessary coil material & components and all precut retrofit roof system framing members from Berridge.
5 6 7
Disclaimer: Project specific engineering required. Consult Engineering Dept. for pricing. Suggested detail shown above may not be applicable to every project.
35
BMC CHICAGO Branch Facility 1175 Carolina Road W. Chicago, Illinois 60185 (630) 231-7495 local (630) 231-7520 fax
BMC DENVER Branch Facility 7505 East 41st Avenue Denver, Colorado 80216 (303) 322-3703 local (303) 322-3810 fax
BERRIDGE CALIFORNIA SALES CORPORATION* 18732 Corby Avenue Artesia, California 90701 (562) 402-2081 local
Berridge Manufacturing Company is registered with the AIA Continuing Education System (AIA/CES) and is committed to developing quality learning activities in accordance with the CES criteria. Please call Berridges Staff Architect at 800-231-8127 to schedule a seminar.
* Berridge California Sales Corporation is a separate entity from Berridge Manufacturing Company.