Heating and Cooling Coils

Coils for All Comfort, Commercial and Industrial Applications

Delta-Flo Fin Design


The Delta-Flo coil features a staggered 1/2-inch tube pattern and unique fin design allowing for low airside pressure drop with high capacity for lower gpm applications. With staggered tubes and its unique fin configuration, the Delta-Flo coil is one of the most efficient half-inch coils available in the industry. Delta-Flo coils are available in the original Delta-Flo E fin surface and the new Delta-Flo H enhanced fin surface. Delta-Flo H fins offer increased capacities and higher moisture carryover limits when compared to the original Delta-Flo E fins. Delta-Flo E and Delta-Flo H are available in aluminum fins.

Sigma-Flo Fin Design


The Sigma-Flo coil is available in a 5/8-inch and 1-inch parallel tube pattern. The Sigma-Flo fin is designed to maximize heat transfer and minimize coil size. The 5/8-inch Sigma-Flo tube pattern is available with COPPER fins only. The 1-inch Sigma-Flo tube pattern for use with steam coils is available with aluminum or copper fins.

Computerized Selection Programs


For quick, easy and accurate coil selections, as well as greater flexibility in design decisions, The Trane Company has developed computerized selection programs. These programs are available from your local Trane office. Coils can be selected for the following: Chilled Water Hot Water Steam Refrigerant

Better Performance Using Trane IVS


Infinitely variable fin spacing (IVS) gives the designer many ways to select the right coil for a particular job. IVS fins are available on all coil fin surfaces for coil selections tailored to application needs. This flexibility is important since coil heating or cooling loads can be matched more precisely than traditional "fixed" fin spacing. For example, a Delta-Flo E cooling coil can be selected from 72 fins per foot to 168 fins per foot in one-fin increments. In many cases IVS fins will allow designers to reduce the number of fins required to meet coil loads. Fewer fins can result in lower airside pressure drops and lower fan brake horsepower, saving valuable energy dollars. Reducing the fan BHP may allow the selection of a smaller fan motor or a smaller air handler, saving additional dollars. Using IVS and the five fin surface options, the designer has more flexibility than ever to design and select coils.

Refrigerant Heat Recovery Coil Runaround Loop Heat Recovery Based on initial input conditions, the programs will calculate capacity, air pressure drop and water pressure drop for all water coils and steam pressure drop for steam coils, including coils with copper fins or coils requiring heavier tube thicknesses. Improve system efficiency with 25 coil types, five fin surfaces, IVS and a wide selection of refrigerant coil circuiting options. Since pumping costs are typically lower than airside operating costs, increase available waterflow to reduce fin requirements and airside pressure drops for fan energy savings.

Prima-Flo Fin Design


The Prima-Flo coil features a parallel 5/8-inch tube pattern. The energy efficient Prima-Flo E fin surface is designed to decrease static pressure loss through the coil. This fin is ideal for systems where airside pressure drop is a major concern. Reducing pressure drop through the coil results in lower fan brake horsepower and system energy savings. Prima-Flo coils are available in the original Prima-Flo E fin surface and the new Prima-Flo H enhanced fin surface. Prima-Flo H fins offer increased capacities and moisture carryover limits when compared to the original Prima-Flo E fins. Prima-Flo E and Prima-Flo H are available in aluminum fins.

American Standard Inc. 1998

C.D.S. Network The Trane Customer Direct Service Network is a computerized engineering
design service providing timetested software and access to personal computer programs. Complete with a communications package to support it, C.D.S. delivers HVAC program updates and user support instantly. With the variety of header design features and material flexibility, along with IVS and computer selection programs, Trane proves again its the leader in coil technology. Infinitely Variable Fin Spacing

Unique Design

Energy Efficient

Cost-Effective

Delta-Flo Prima-Flo and Sigma-Flo

More Coils for More Uses

Cooling Coils
CHARACTERISTICS ROWS 2, 3, 4, 6 8, 10, 12 FINNED WIDTH CAST IRON HDR 12, 18, 24, 30, 33 FINNED LENGTH 12"-168" FINS PER FOOT ALUMINUM 80-168 MAX. STD. OPERATING CONDITIONS TUBE PSI TEMP (F) MATERIAL (TUBE SIDE) COPPER 5 8" OD .020" .024" .035" RED BRASS .049" 200 220

W
AIR FLOW

GENERAL PURPOSE DRAINABLE AT HEADER FULL-ROW SERPENTINE CHILLED WATER

WATER IN

COPPER HDR 36, 42, 48, 54"

12"-168"

COPPER 96-168

WATER OUT

K
AIR FLOW


WATER IN

CLEANABLE DRAINABLE AT EACH ROW FULL-ROW SERPENTINE CHILLED WATER

2, 4, 6 8, 10, 12

12, 18, 24 30, 33"

12"-168"

ALUMINUM 80-168

COPPER 5 8" OD .020" .024" .035" RED BRASS .049"

200

220

3* COPPER 96-168

WATER OUT

P2
AIR FLOW

LOW GPM TWO-TUBE FEED CHILLED WATER

2, 4, 6

12, 18 24, 30"

12"-120"

ALUMINUM 80-168

COPPER 5 8" OD .020" .024" .035" RED BRASS .049"

200

220

WATER OUT

WATER IN

COPPER 96-168

P4
AIR FLOW

LOW GPM FOUR-TUBE FEED CHILLED WATER

2, 4 6, 8

12, 18 24, 30"

12"-120"

ALUMINUM 80-168

COPPER 5 8" OD .020" .024" .035" RED BRASS .049"

200

220

WATER OUT

WATER IN

COPPER 96-168

P8

AIR

FLOW

LOW GPM EIGHT-TUBE FEED CHILLED WATER

4, 8

18, 24 30"

18"-120

ALUMINUM 80-168

COPPER 5 8" OD .020" .024" .035" RED BRASS .049"

200

220

COPPER 96-168
WATER OUT WATER IN

D
AIR FLOW

DRAINABLE AT EACH ROW FULL-ROW SERPENTINE CHILLED WATER

4, 6, 8 10, 12

12, 18, 24 30, 33"

12"-168"

ALUMINUM 80-168

COPPER 5 8" OD .020" .024" .035" RED BRASS .049"

200

220

3*
WATER IN

COPPER 96-168

WATER OUT

CHARACTERISTICS

ROWS 4,8,12 6, 10*

FINNED WIDTH CAST IRON HDR 18, 24, 30, 33

FINNED LENGTH 18"-168"

FINS PER FOOT ALUMINUM 80-168

MAX. STD. OPERATING CONDITIONS TUBE PSI TEMP (F) MATERIAL (TUBE SIDE) COPPER 5 8" OD .020" .024" .035" 200 220

DD WD

(DD)

AIR FLOW WATER IN

WATER OUT

(WD)

DRAINABLE AT EACH ROW HIGH GPM LOW WATER PRESSURE DROP OPPOSITE-END CONNECTIONS ON 6 & 10 ROWS DUAL-ROW SERPENTINE CHILLED WATER DRAINABLE AT HEADER HIGH GPM LOW WATER PR ESSURE DROP SAME-END CONNECTIONS ON 6 & 10 ROWS DUAL-ROW SERPENTINE CHILLED WATER

6, 8 10, 12

CAST IRON HDR 18,24, 30,33" COPPER HDR 36, 42, 48, 54" 12, 18, 24 30, 33, 36, 42, 48, 54" 12"-168"

COPPER 96-168

RED BRASS .049"

WL
AIR FLOW

GENERAL PURPOSE FULL-ROW SERPENTINE CHILLED WATER


WATER IN

2, 4 6, 8

ALUMINUM

COPPER 1 2" OD .016" .025"

200

220

DELTA-FLO E 72-168 DELTA-FLO H 84-168

WATER OUT

DL
AIR FLOW

DRAINABLE AT HEADER FULL-ROW SERPENTINE CHILLED WATER


WATER IN

2, 4, 6

12, 18, 24, 30, 33, 36 42, 48, 54"

12"-168"

ALUMINUM

COPPER 1 2" OD .016" .025"

200

220

DELTA-FLO E 72-168 DELTA-FLO H 84-168

WATER OUT

LL
WATER IN
AIR FLOW

DRAINABLE AT HEADER HIGH GPM LOW WATER PRESSURE DROP DUAL-ROW SERPENTINE CHILLED WATER

4, 6, 8

18, 24, 30 33, 36, 42 48, 54"

18"-168"

ALUMINUM

COPPER 1 2" OD .016" .025"

200

220

DELTA-FLO E 72-168 DELTA-FLO H 84-168

WATER OUT

F
AIR FLOW

REFRIGERANT LIQUID IN

REFRIGERANT GAS OUT


AIR FLOW

REFRIGERANT CIRCUITING AVAILABLE: STANDARD HORIZONTAL SPLIT VERTICAL SPLIT

2, 3, 4 6,8

12, 18, 24 30, 33"

12"-168"

ALUMINUM 80-168 COPPER 96-168

COPPER 5 8" OD .020" .024"

300

REFRIGERANT LIQUID IN REFRIGERANT GAS OUT

FD
REFRIGERANT LIQUID IN

REFRIGERANT CIRCUITING AVAILABLE: STANDARD HORIZONTAL SPLIT VERTICAL SPLIT INTERTWINED

4, 6

18, 24, 30 33, 36, 42 48"

18"-168"

ALUMINUM

COPPER 1 2" OD .016" .025"

300

DELTA-FLO E 72-168 DELTA-FLO H 84-168

REFRIGERANT GAS OUT

Heating Coils
CHARACTERISTICS ROWS 1* FINNED WIDTH 6, 9, 12, 18 24, 30, 33" FINNED LENGTH 12"-168" FINS PER FOOT ALUMINUM 80-168 MAX. STD. OPERATING CONDITIONS TUBE PSI TEMP (F) MATERIAL (TUBE SIDE) COPPER 5 8" OD .020" .024" .035" RED BRASS .049" 200 200 325 (1-ROW) 220 (2-ROW)

WA

WATER OUT

DRAINABLE AT HEADER LOW GPM ALTERNATIVE-TUBE FEED HOT WATER

2
WATER IN

12, 18, 24, 30, 33""

COPPER 96-168

200 200

388 (1-ROW) 220 (2-ROW)

WC


WATER OUT

DRAINABLE AT HEADER ONE-ROW SAME-END CONNECTION HOT WATER

CAST IRON HDR. 12, 18, 24 30, 33" COPPER HDR 36, 42, 48"

12"-168"

ALUMINUM 80-168

COPPER 5 8" OD .020" .024" .035" 200 RED BRASS .049" (CAST IRON HDR ONLY) 250

COPPER 96-168

WATER IN

W
AIR FLOW WATER IN

GENERAL PURPOSE DRAINABLE AT HEADER FULL-ROW SERPENTINE HOT WATER

1*

6, 9, 12, 18 24, 30, 33"

ALUMINUM 80-168

WATER OUT

(CAST IRON HDR) 12, 18, 24 30, 33" (COPPER HDR) 36, 42, 48, 54"

12"-168"

COPPER 96-168

COPPER 5 8" OD .020" .024" .035" RED BRASS .049"

200 200

325 (1-ROW) 220 (2-ROW)

200 200

388 (1-ROW) 220 (2-ROW)

TT

WATER OUT

LOW GPM COMMON DUCT COIL TWO-TUBE FEED HOT WATER

12, 18 24, 30"

ALUMINUM 80-168

9, 12, 18 24, 30, 33"

12"-96"

COPPER 96-168

COPPER 5 8" OD .020" .024" .035" RED BRASS .049"

225

250

275 350

350 400

WATER IN

ST
WATER OUT

LOW GPM OR MODERATE STEAM PRESSURES COMMON DUCT COILS T HAS STANDARD CASING. ST HAS SLIP FLANGE CASING FOR QUICK FIT-UP HOT WATER OR STEAM

6, 9, 12 15, 18"

(T) 6"-72" (ST) 6-42

ALUMINUM 80, 110, 150

COPPER 96, 110, 144 2

COPPER 5 8" OD .020" .024" 035"

WATER 200 STEAM 100

250 400

WATER 275 STEAM 350

350 400 400 450

WATER IN

RED BRASS WATER 350 .049" STEAM 400

Notes: 1. Turbulators are available in water coils to increase capacities at low fluid flow rates. 2. Special material construction, operating pressures and temperatures are available. 3. All chilled water coils can be used in hot water applications. 4. Drain and vent connections are standard on all water coils. 5. All finned lengths are available in one inch increments (except T and ST coils). 6. All fin spacings are available in one fin per foot increments. *Opposite-end connection. ARI certification does not exist for type H coils.

CHARACTERISTICS

ROWS 1*

FINNED WIDTH 6, 9, 12, 18, 24, 30 33

FINNED LENGTH 12"-120"

FINS PER FOOT ALUMINUM 80-168 COPPER 96-168

MAX. STD. OPERATING CONDITIONS TUBE PSI TEMP (F) MATERIAL (TUBE SIDE) COPPER 5 8" OD .020" .024" .035" RED BRASS .049" 100 400

(A)

UNMODULATED STEAM TYPE FULL-ROW FEED STEAM

STEAM IN

200

400

CONDENSATE OUT

N NS
STEAM IN

(N)

MODULATING STEAM TYPE STEAM DISTRIBUTING TYPE FULL-ROW FEED OPPOSITE-END CONNECTIONS

1*

12, 18, 24 30, 33 30,33"

12"-144"

ALUMINUM 42-132

COPPER 1" OD .031"

100

400

(NS)

SAME-END CONNECTIONS STEAM

COPPER 42-132

RED BRASS .049"

200

400

CONDENSATE OUT

H
AIR FLOW

REFRIGERANT 1-100% HEAT RECOVERY MULTIPLE-COMPRESSOR CIRCUITS

1,2 3,4 6

12, 18, 24, 30, 33, 36 42, 48" 54 (2-6 ROW ONLY)

24"-168"

ALUMINUM 80-168

COPPER 5 8" OD .020"

300

REFRIGERANT GAS IN REFRIGERANT GAS/ LIQUID OUT

WL
AIR FLOW WATER IN

GENERAL PURPOSE FULL-ROW SERPENTINE HOT WATER

12, 18, 24 30, 33, 36 42, 48, 54"

12"-168"

ALUMINUM

COPPER 1 2" OD .016" .025"

200

220

DELTA-FLO E 72-180 DELTA-FLO H 84-180

WATER OUT

DL
AIR FLOW WATER IN

DRAINABLE AT HEADER FULL-ROW SERPENTINE HOT WATER

12,18,24 30, 33, 36 42, 48, 54"

12"-168"

ALUMINUM DELTA-FLO E 72-180 DELTA-FLO H 84-180

COPPER 1 2" OD .016"

200

220

.025"

WATER OUT

File No. COIL-TS-1 August 1998

Worldwide Applied Systems Group The Trane Company 3600 Pammel Creek Road La Crosse, WI 54601-7599 www.trane.com An American Standard Company

Supersedes COIL-TS-1-1189 File No. PL-AH-COIL-000-TS-1-898

Since The Trane Company has a policy of continuous product improvement, it reserves the right to change design and specification without notice.