Você está na página 1de 2

JDL CLASS J

TIME-DELAY FUSES

Catalog Number JDL (1 - 600A) 600 Volts AC or Less

1
1.25
1.6
2
2.5
3
3.5

4
5
5.6
6
7
8
10

AMPERE RATINGS
JDL 600V
12
40
15
45
17.5
50
20
60
25
70
30
80
35
90

JDL SPECIFICATIONS
Dual-Element, Time-Delay
100
110
125
150
175
200
225

250
300
350
400
450
500
600

EDISON JDL Class J fuses are among the most current limiting time-delay fuses available. Their small physical size
and high performance characteristics makes Class J fuses
ideal for any space - limited application.

Voltage Rating:

JDL - 600VAC

Ampere Rating:

1 - 600 Amps

Interrupting Rating:

200,000 RMS Symmetrical Amps


300,000 RMS Symmetrical Amps
Self-Certified

Current Limiting:

Class J Fuse

Agency Approvals:
UL Listed, Class J, Guide JDDZ, File E162363
CSA Certified HRCI-J per C22.2, No. 248.8
Self-Certified DC Ratings:
Voltage Rating: JDL (1-600) 300VDC
Interrupting Rating: JDL 20,000 Amperes DC

BENEFITS:
Space saving dimensions vs Class R.
Dual-Element construction provides superior time-delay
to pass harmless motor or transformer surges.
High performance with fatigue - free cycling capabilities.
Extremely current limiting.
APPLICATIONS:
Recommended for Type 2 (no damage) protection of IEC
style motor starters and contactors.
Use to protect lower interrupting rating circuit breakers.
All general purpose circuits with inductive (high inrush)
loads, including motor and motor branch circuits, and
transformer circuits. Also suitable for lighting loads.

18

RECOMMENDED FUSEBLOCKS:
Refer to page 137 in this catalog.
RECOMMENDED UPGRADE:
None.

EDISON

CROSS REFERENCE
BUSSMANN
GOULD

LITTELFUSE

JDL

LPJ

JTD

AJT

JDL CLASS J
TIME-DELAY FUSES

.2

AMPERE
RATING

1,000
800
600
400
300
200

100

100

.1
.08
.06

200,000

.4
.3

2,000

60,000
80,000
100,000

1
.8
.6

4,000
3,000

30,000
40,000

20,000

4
3

10,000
8,000
6,000

6,000
8,000
10,000

TIME IN SECONDS

10
8
6

7
6
3

20,000

3,000
4,000

20

10

2,000

40
30

40,000
30,000

600
800
1,000

100
80
60

300
400

200

100,000
80,000
60,000

INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS

Ampere
Rating

200

600A

400A

200A
225A

125A

100A

15A
20A
30A
40A
50A
60A

300

10A

Cat. No. JDL (Amp) 600V

5A

Cat. No. JDL (Amp) 600V


3A

PEAK LET-THROUGH CURRENT CURVES

1A

AVERAGE TIME/CURRENT CURVE

RMS SYMMETRICAL CURRENTS IN AMPERES


AB=ASYMMETRICAL AVAILALBE PEAK (2.3 X SYMM RMS AMPS)

.04
.03

4,000
3,000

AMPERE
RATING

2,000
1,000
800
600
400
300

200,000

60,000
80,000
100,000

30,000
40,000

20,000

100

6,000
8,000
10,000

200

3,000
4,000

600A

8,000
9,000
10,000
11,100
11,800
12,500
13,270
13,820
15,000
16,000
17,270
19,270
20,600

2,000

400A

4,400
5,540
6,420
7,000
7,500
8,000
8,330
9,000
9,380
10,000
11,270
12,180
14,360
15,820

600
800
1,000

1,000
3,000
5,000
10,000
15,000
20,000
25,000
30,000
35,000
40,000
50,000
60,000
80,000
100,000
150,000
200,000

Let-Thru Current (Apparent RMS Symmetrical)


JDL (600V) Fuse Ratings
15A
30A
60A
100A
200A
270
470
750

370
670
1,130
1,640
2,360
450
800
1,420
1,910
2,760
550
1,000
1,730
2,450
3,520
625
1,220
1,890
2,850
4,000
700
1,330
2,120
3,090
4,400
750
1,440
2,250
3,400
5,000
800
1,530
2,370
3,650
5,140
820
1,600
2,580
3,780
5,430
900
1,640
2,670
4,000
5,640
925
1,760
2,790
4,470
6,000
1,000
1,850
3,000
4,670
6,420
1,160
2,000
3,220
5,000
7,400
1,220
2,150
3,520
5,360
7,950
1,400
2,460
4,000
6,170
9,000
1,560
2,640
4,450
7,000
10,000

100
60
50
40
30
20
15

10,000
8,000
6,000

300
400

*Prosp.
S.C.C.

200

20,000

200

Current-Limiting Effects

600
400

40,000
30,000

100

RMS SYMMETRICAL CURRENT IN AMPERES

100,000
80,000
60,000

INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS

6,000
8,000
10,000

3,000
4,000

2,000

600
800
1,000

300
400

200

60
80
100

30
40

20

6
8
10

3
4

.01

.02

RMS SYMMETRICAL CURRENTS IN AMPERES


AB=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS)

*RMS Symmetrical Amperes Short-Circuit Current.


NOTE: Data derived from Current Limiting Curves.

DIMENSIONS
Refer to JFL Section on page 20.

19

Você também pode gostar