Product Description Electroheat Digital 55 Mk II Electroheat Digital 80 Mk II Electroheat Plus 85 Mk II Electroheat Plus 85 Mk II (3 Phase) Electroheat Plus 105 Mk II (3 Phase) Electroheat Plus 125 Mk II (3 Phase) Electroheat Plus 150 Mk II (3 Phase)
Sizing chart to heat your pool to 28 C Temperate Location* 12hrs / Day Runtime Pool Size (m) 3x7 3.5 x 7 4 x 8.5 5 x 10 5.5 x 11 6 x 12 6 x 15 Litres Up to 35000 Up to 38000 Up to 57000 Up to 76000 Up to 95000 Up to 114000 Up to 133000 with Pool Cover 55 55 80 105 125 150 see dealer 14hrs / Day Runtime Warm Location* 12hrs / Day Runtime 14hrs / Day Runtime
No Pool with Pool No Pool with Pool No Pool with Pool No Pool Cover Cover Cover Cover Cover Cover Cover 80 55 55 55 55 55 80 105 55 80 55 80 55 55 125 55 125 55 105 55 85 see dealer 85 150 80 150 55 125 see dealer 105 see dealer 85 see dealer 80 150 see dealer 125 see dealer 105 see dealer 85 150 see dealer 150 see dealer 150 see dealer 125 see dealer
Please note : Heat pump sizing is influenced by ambient temperature , humidity , presence of a pool cover , nightly temperatures , pool location , wind factor water features and hours of operation . * Temperate location: Where minimum average daytime temperatures between September to May are not less than 18C. * Warm location: Where minimum average daytime temperatures between September to May are not less than 26C .
Technical Specifications Specifications Nominal Heating Capacity btu * Power Output (kW) Supply Voltage (VAC) Supply Voltage Phase Power Consumption (kW/h) Unit Running Amperage (AMP) Fan Full Load Amp (FLA) Breaker or Fuse (AMP) Min./Max. Ambient Air Temperature (C) Min./Max. Water inlet (C) Water Connections (mm) Min./Max. Water Flow Rate LPM Weight (kg) Dimensions A x B x C (mm) Electroheat Electroheat Electroheat Plus Electroheat 55 MKII 80 MKII 85 MKII Plus 105 MKII 55,000 16 240 80,000 23 240 240 Single phase 6.5 29.4 1 40 12 - 40 14/40 40 170 - 200 84 750 x 850 x 1000 25 12 - 40 14/40 40 170 - 200 85,000 25 415 Three Phases 6.5 11.1 105,000 31 415 Three Phases 7.2 11.4 1 25 12 - 40 14/40 40 170 - 200 87 Electroheat Plus 125 MKII 120,000 36.5 415 Three Phases 7.1 10 1 25 12 - 40 14/40 40 170 - 200 89 890 x 880 x 1130 Electroheat 150 MKII 150,000 44 415 Three Phases 7.9 16.4 1 25 12 - 40 14/40 40 170 - 200 93
Single phase Single phase 4.2 17.4 1 30 12 - 40 14/40 40 170 - 200 59 735 x 560 x 815 6.8 29.4 1 40 12 - 40 14/40 40 170 - 200 78 915 x 610 x 865
Model Electroheat MK II 55 Electroheat MK II 80 Electroheat Plus MK II 85 Electroheat Plus MK II 105 Electroheat Plus MK II 125 Electroheat Plus MK II 150
Product Description Electroheat SubZero 55 Electroheat SubZero 75 Electroheat SubZero 75 (three phase) Electroheat SubZero 100 (three phase)
Nominal Size 16 Kw 22 Kw 22 Kw 31 Kw
Sizing chart to heat your pool to 28 C Model Regional average daytime temperatures Between September to April Over 20C 18C to 23C 10C to 15C 55 55 75 55 75 100 75 75 100 75 100 100 100 100 See Dealer 100 See Dealer See Dealer 100 See Dealer See Dealer
Surface Area m2 21 28 32 36 45 50 55
Please note: Heat pump sizing is influenced by ambient temperature, humidity, presence of a pool cover, nightly temperatures, pool location, wind factor, water features and hours of operation.
Technical Specifications Models Nominal Heating Capacity btu * Power Output (Kw) Supply Voltage (VAC) Supply Voltage Phase Power consumption (kW/h) Unit Running Amperage Fan Full Load Amp (FLA) Min / Max Breaker or Fuse (AMP) Min./Max. Air Inlet Temperature (C) Water Bypass Type Min./Max. Water Flow Rate (LPM) Min./Max. Water Inlet Temperature (Degrees C) Plumbing Connection Size (Inch. / mm ) ElectroHeat Subzero 55 55,000 BTU 16 240 1 phase 4 16.9 1.0 30 - 40 0 - 40 Ext. Field Install 180 - 225 12 - 40 1 - 1/2 / 40mm 40 - 50 0 - 40 Ext. Field Install 180 - 225 12 - 40 1 - 1/2 / 40mm 240 1 phase 5.4 22.4 1.0 25 0 - 40 Ext. Field Install 170 - 200 12 - 40 1 - 1/2 / 40mm ElectroHeat Subzero 75 75,000 BTU 22 415 3 Phases 5.3 10.1/ Phase ElectroHeat Subzero 100 100,000 BTU 31 415 3 Phases 7.2 10.4 /Phase 1.0 25 0 - 40 Ext. Field Install 180 - 225 12 - 40 1 - 1/2 / 40mm
SubZero 55 90kg
SubZero 75 108kg
Product Description LLC 125 LLC 175 LLC 250 LLC 325 LLC 400 Temperature Rise Measurement Kit All heaters are available for Natural Gas or LPG - Propane N - Natural, V - Outdoor , P - Propane, D - Indoor Note: Prices do not include delivery charges
Product Description LJ125 LJ175 LJ250 LJ325 LJ400 Indoor Vent Cap All heaters are available for Natural Gas or LPG - Propane N - Natural, V - Outdoor , P - Propane, D - Indoor
Spa Size 750 litres 1500 litres 2250 litres 3000 litres 3750 litres
LLC 250 15 30 45 60 75
LLC 325 12 23 35 46 58
LLC 400 9 19 28 37 47
Model No.
Gas Consumed
Heat Output
Nom. MJ/hour Nom. Natural LPG Natural 131 118 29 184 166 41 263 236 59 341 307 76 420 377 94
LPG Only Qty. LPG 45kg Continuous Time to Water flow through cylinders use one LPG cyl. heater lpm kW - min.* - hours Min. Max. LPG 26.5 2 17 76 475 37 2 12 76 475 53 3 8.2 95 475 68.5 4 6.4 114 475 84.5 4 5.3 114 475
Stack Dimensions Outdoor Indoor A B A 197 359 197 234 371 235 289 476 289 346 457 346 410 527 410
A 114
V W 419 254
203 724
Product Description Waterco Single Phase Heater Waterco 3 Phase Heater Waterco 3 Phase Heater
18kW & 24kW Three phase Body : 316 grade Stainless Steel
Thermostat temperature adjustment Over-temperature sensor Maximum temperature Pressure switch settings Maximum working pressure Maximum pressure International protection rating Amps - 6kW Amps per phase - 18kW Amps per phase - 24kW
: : : : : : : : : : :
20 deg C - 40 deg C 45 deg C 70 deg C On 35 kPa (3.5m head) Off 15 kPa (1.5m head) 250 kPa 350 kPa IP23 25 amps 25 amps 34 amps
COLD
HOT
260mm wide
480mm
OVERALL HEIGHT
500mm 240mm
OVERALL HEIGHT
265mm
45mm
50mm