1. BUILDING DESCRIPTION :
Width (I/I) = 25330 mm
Length (column C/C) = 129720 mm
Bay spacing = 5@7560 + 8000 + 2@7500 + 8000 + 7@7560 +8000
Clear height at side wall = 19500 mm
MATERIAL STD
ASTM A 572 GR50
ASTM A 1011/ 570 GR50
IS 4923
ASTM A 325 M
IS2016
IS 2062
YIELD
STRENGTH
TENSILE
STRENGTH
345 MPA
345MPA
210 MPA
660 MPA
450 MPA
450 MPA
410 MPA
830 MPA
240 MPA
410 MPA
COMPONENTS
CONNECTOR ANGLE, SHOE, FRAME/TOP-AISLE
CONNECTOR PLATES
UPRIGHTS, CROSS BEAMS, FRAME BRACINGS, SPLICE
FRAME CONNECTORS
FASTNERS, EXPANSION BOLTS
WASHERS
BRACE RODS (PLAN, AISLE, SPINE)
4. DESIGN ASSUMPTIONS:
During the validation of SANATAN Plant layout, the following assumptions are made in order to simplify or
make the validation more conservative.
Design validation carried out at two stages. In first stage, the whole plant was modeled with equivalent 1Dimensional BEAM element with appropriate Cross-sectional properties. In Second stage, the sub-model of
plant is modeled with 2-Dimensional SHELL elements with appropriate thickness properties.
4.1.
- To be conservative the weakest section properties considered for modeling all components in SANTAN Plant
-Section properties calculated at C.G of the weakest section for each component
-Complete plant layout is modeled as three blocks and rested on uprights with fixed boundary condition [all
DOF constrained]
-Shoe is not considered during 1D element analysis [BEAM model]
-Live loads and Seismic loads distributed at the joint location of Upright and Box beams on which pallets are
mounted
4.2.
5. DESIGN VALIDATION:
5.1.
Objective :
To validate the structural design proposed by Kirby after analysis of the same with live load and dead load
with seismic loads applied following the code book IS-1893.
The proposed structure was already in accordance with the EN 155512, EN 15620.
(please correct the content accordingly to maintain a standard).
5.2.
5.3.
5.4.
1D- RESULTS :
5.5.
5.6.
3D RESULTS
5.7.