Product Highlights
Point-to-point digital microwave connection QPSK Modulation RF Frequency bands of 7/8/13/15/18/23/26/28/38 GHz Transmission capacity of: 2x2,4x2,8x2,16x2 MBit/s with Wayside option for 16x2 MBit/s Hot-standby or diversity - hitless solution 10BASE-T/100BASE-TX LAN capacity Automatic Transmission Power Control Function

System Architecture of V4
IDU
SW UNIT MD UNIT

ODU

ANT

PDH IN/OUT PNMS LCT

WS IN/OUT

OW IN/OUT

Hot Standby System

Space Diversity Twin Path System

Combined Redundancy Options

Bandwidth - Capacity
MODULATION: 4PSK
2 x 2MB or LAN

4 x 2MB or N x 2MB + LAN


7 MHz

8 x 2MB or N x 2MB + LAN


14 (13,5) MHz

16 (17) x 2MB or N x 2MB LAN


28 (27,5 or 29,65) MHz

PASOLINK V4

3,5 MHz

Packing List for IDU and ODU

No.
1 2 3 4 5

Description
TRP-( )G( )MB-( ) A (ODU) O-Ring (Attached to the waveguide type ODU) O-Ring (Attached to the antena direct mounting type ODU) MDP-( )MB-( ) (IDU) Power Connector (Molex Housing M5557-4R) (xlea) Cabel Terminal (Molex 5556T) (x4ea)

6 7 8

7.5 Fuse (SMP75) (x 2ea) 7-8 GHz HYB (x1) for 1+1, with N-type or SMA coaxial cable connectors 13-38 GHz HYB (x1) for 1+1

PASOLINK V4
THE OUTDOOR UNIT

ODU Physical Parameters 7/8 GHz

Weight / Approx. 3 Kg Dimension / 240mm (W )x 243 mm (H) x 90 mm (D) Power Supply / -43V Power Consumption / 40 W Temperature range
Guaranteed Operation / - 33 C to + 50 C Workable Operation / - 40 C to + 55 C Transport and storage / - 40 C to + 70 C

Relative Humidity / Less then 90% at 50 C Altitude / Up to 4000 m

ODU Physical Parameters 13-38 GHz

Weight / Approx. 3 Kg Dimension / 240mm (W )x 243 mm (H) x 90 mm (D) Power Supply / -43V Power Consumption / 40 W Temperature range
Guaranteed Operation / - 33 C to + 50 C Workable Operation / - 40 C to + 55 C Transport and storage / - 40 C to + 70 C

Relative Humidity / Less then 90% at 50 C Altitude / Up to 4000 m

Composition of ODU

Location No.
1 2 3

Module
Radio Frequency Circuit Intermediate Frequency Circuit Power Supply

ODU Block Diagram

IF ( Intermediate Frequency ) MIX ( Mixer ) BPF ( Band Pass Filter ) LNA ( Low Noise Amplifier ) LO ( Local Oscillator ) DUP ( Duplexer ) MPX ( Multiplexer )

Sub-band Changing
A
Full band cover RF CKT
fc

fc

Changable Filters

TX BPF

RX BPF

Az RF CKT of ODU covers the full band, only filter change is required Fewer ODU needed

ODU Interface Terminal


IF IN/OUT: N Type Connector RF IN/OUT: 7/8 GHz ODU: SMA or N Type Connector 13-38 GHz ODU: Direct Mounted or Waveguide OW/Rx Level Monitor Point: F type Male Connector FG: Frame Ground Screw

OW/RX LEV MON

Controls, Indicators andTest Jacks of OW/RX LEV Monitor


OW On Off Switch
Enables to transmission of OW signal between IDU and ODU Adjust receive OW voice level Input connector for RX level monitoring voltage and OW signal Permits communication IDU and ODU when orderwire headset is connected Indicates receiving RF level monitoring voltage Lights when OW communication is performed

VOL Control

RX LEV/OW in HeadSet Jack

Meter

OW Indicator

Setting The Polarization

PROCEDURE FOR SETTING V/H POLARIZATION

When vertical polarization is required, rotate the IDU so that the plate marked with V is pointing up. Fix the ODU in this position

When horizontal polarization is required, rotate the IDU so that the plate marked with H is pointing up. Fix the ODU in this position

ODU Type and Frequency Indication Label


ODU Type
PASOLINK TRP-()G-1AA Sub Band Tx Frequency High/Low

Serial Number Date of Manufacturing Weight

ODU Performance I.

ODU Performance II.

PASOLINK V4
THE INDOOR UNIT

IDU (1+0) Configurations

IDU (1+1) Configurations

4x2M, Fixed Bit Rate system

4x2M, Fixed Bit Rate system with LAN Interface

2/4/8/16x2M Bit Rate Free system

2/4/8/16x2M Bit Rate Free system with LAN interface

Optional Cards
6 5 4 2 3 1
1 - ASC, DSC, ALM Interface 2 - 64K Interface 3 - WS Interface 4 - SC LAN Interface 5 - Supervisory Card 6 - LAN Interface

Composition of IDU (1+1 system)


No.
U2 U1 U3 U1 U2 U3 1 2 10 11 3 4 5 1 4 8 9 7 3 2 12 6 7 8 9 10 11 12

Description
Switching Unit Modulator-Demodulator Unit Modulator-Demodulator Unit Main Board Front Board 1 DC-DC Converter SW Board Front Board 1 Front Board 2 64K Interface WS Interface ASC, DSC, ALM Interface LAN Interface Supervisory Card SC LAN Interface

IDU Block Diagram

Pasolink V4 1+0 Interface


2Mb INTFC (Ch. 9 Ch. 16)

LEDs PWR MAINT ODU IDU


WS/LAN (Optional) NMS LAN for PNMS EOW
CALL SWITCH

IF INTFC

LAN INTFC (Port1&Port2)

CPU RESET

ALM/AUX ALM 2Mb INTFC (Ch. 1 Ch. 8) OW/ASC/DSC LA Port for LCT

FUSE DC IN

POWER SW NMS/RA for PNMS or LCT

Interfaces (1+0 system)


Interface
Traffic IN/OUT (CH 1 CH 8) Traffic IN/OUT (CH 9 CH 16) 10/100BASE-T IN/OUT (PORT1&PORT2) IF IN/OUT

Description
2.048 Mbps HDB3 coded data input/output 2.048 Mbps HDB3 coded data input/output LAN signal input/output (optional) TX IF to ODU and RX IF from ODU Engineering Orderwire, Digital and Analog Service Channels and Alarm signal input/output Alarm and transmission network surveillance alarm input/output NMS input/output or RA input/output Control/Monitoring signal input/output from/to PC PNMS input/output Way side signal/DSC data for LAN

Connector
D-sub Connector, 37 Pins D-sub Connector, 37 Pins RJ-45, 8 Pins N-P Connector

OW/DSC/ASC

D-sub Connector, 25 Pins

ALM/AUX ALM NMS/RA LA PORT NMS LAN WS/SC LAN

D-sub Connector, 37 Pins D-sub Connector, 15 Pins D-sub Connector, 15 Pins RJ 45, 8 Pins RJ45, 8 Pins

Pasolink V4 1+1 Interface


LAN INTFC (Port1&Port2) NMS LAN for PNMS 2Mb INTFC (Ch. 9 Ch. 16) WS/LAN (Optional) EOW
CALL SWITCH

CPU RESET

DC IN

IF INTFC POWER SW

ALM 2Mb INTFC (Ch. 1 Ch. 8)

OW/ASC/DSC

LA Port for LCT

FUSES

AUX ALM

NMS/RA for PNMS or LCT

OPERATION SELECT

Interfaces (1+1 system)


Interface
Traffic IN/OUT (CH 1 CH 8) Traffic IN/OUT (CH 9 CH 16)

Description
2.048 Mbps HDB3 coded data input/output 2.048 Mbps HDB3 coded data input/output

Connector
D-sub, 37 Pins D-sub, 37 Pins RJ-45, 8 Pins N-P Connector

10/100BASE-T IN/OUT (PORT1&PORT2) LAN signal input/output (optional) IF IN/OUT TX IF to ODU and RX IF from ODU Engineering Orderwire, Digital and Analog Service Channels and Alarm signal input/output Alarm and answer signal input/output Transmission network surveillance auxiliary NMS input/output or RA input/output Control/Monitoring channels from/to PC PNMS input/output DSC data for LAN Way side signal/DSC data for LAN

OW/DSC/ASC

D-sub, 25 Pins

ALM AUX ALM NMS/RA LA PORT 1&2 NMS LAN SC LAN WS/SC LAN

D-sub, 37 Pins D-sub, 25 Pins D-sub, 15 Pins D-sub, 15 Pins RJ 45, 8 Pins RJ 45, 8Pins RJ45, 8 Pins

INDICATORS/SWITCHES/CONTROLS
PWR SW Turns input DC power ON/OFF RESET SW Initialize CPU MAINT LED
Maintenance Mode ON Loopback control ONl CW mode ON Power Mute ON BER AIS Inhibit

ODU LED
Transmit RF power decrease by 3 dB from nominal Receiver level goes below squelch level ODU local oscillator APC loop unlock IF signal from IDU is low

CALL SW EOW calling signal, opposite station buzzer rings

TX ALM 1/2 LED


ODU 1/2 TX RF Power decrease by 3 dB from nominal ODU 1/2 local oscillator APC loop unlocks ODU 1/2 Input IF signal lost CH 1/2 Master clock signal or output data loss at TX DPU CH 1/2 Modulator VCO synchronization is lost CH 1/2 CPU communication between IDU and ODU is lost WS channel usage error in setting Traffic usage error in setting

TX OPR 1 LED When Tx side of IDU 1 & ODU 1 is online TX OPR 2 LED When Tx side of IDU 2 & ODU 2 is online OPR SEL NO1. Manually selected CH Mo.1 Automatic redundancy switch control NO2. Manually selected CH Mo. 2

RX ALM 1/2 LED


ODU 1/2 RX level falls below squelch level ODU 1/2 local oscillator APC loop unlocks CH 1/2 DEM IF signal lost HBER worse than 1x10-3 BER worse than preset threshold CH 1/2 Frame synchronization lost at the DPU CH 1/2 CPU communication between ODU and IDU is lost

RX OPR 1 LED When Rx side of IDU 1 & ODU 1 is online RX OPR 2 LED When Rx side of IDU 2 & ODU 2 is online

IDU LED
Input data stream of CH() from DTE lostl AIS signal from CH() received from DTE DPU TX/RX synchronization lostt AIS signal sent out on CH() Bipolar output pulse of CH() is lost at 2M INTFC Traffic channel usage of CH() error in setting HBER is worse than 1x10-3 at DPU section BER is worse than preset threshold value Carrier synchronization lost at DEM section MOD VCO synchronization lost Output data stream/Master clock lost at TX DPU Frame synchronization is lost at the DPU section WS channel usage error

When the IF cable between the IDU and ODU is disconnected IDU and ODU ALM LEDs start flashing

Switching Function of BaseBand Impedance

WS - 120 OHM TRAFFIC CHANNELS IN 120 OHM MODE

WS - 75 OHM TRAFFIC CHANNELS IN 75 OHM MODE

Service Channels

Engineering Order Wire ( EOW )

Buzz

Back-to-back connection

Buzz

Buzz

Communication between Local IDU and Local ODU

Communication between Local IDU and Remote IDU

Communication between Local ODU and Remote ODU

Communication between Local ODU and Remote IDU

When back-to-back connection for order wire is provided, OW communication between different hops are possible.

Automatic Transmitter Power Control


-10 -20 RECEIVE -30 SIGNAL LEVEL -40 (dBm) -50 -60 -70

Non ATPC

RSL detection

ATPC

Error detection

TRANS- +20 MISSION +18 POWER (dBm) +3

-20

-10

+10 +20 +30 +40 +50

FADE DEPTH (dB)

ATPC, Functional Block Diagram

ATPC MTPC Application


ATPC ATPC MTPC MTPC ATPC MTPC MTPC - ATPC

Loopback Locations

a) b)

Near end LoopBack for BaseBand on the Local site Far end LoopBack for BaseBand on the Remote site

LAN Based Applications

Traffic Channel LAN Assignment

IDU Type and Bandwith Indication Label


IDU Type PASOLINK MDP-()MB-A Serial Number Date of Manufacturing ( DATE ) Weight

IDU Performance I.

IDU Performance II.

PASOLINK V4
SYSTEM PERFORMANCE

V4 Channel Summary
Baseband Transmission
2, 4, 8, 16x2 Mb (E1) 10/100 Base-T

Service Channels
Engineering Orderwire: 1 VF SC1&2: 2x9.6 Kb/s RS-232/485/422 SC 3&4: 2x analog VF (ASC) OR 2x9.6 RS-232/422 (DSC) OR 64K (2M) LAN (SC LAN)

Wayside Channel
1x2 Mb E1 (In 16x2 mode)

System Performance I.

System Performance II.

Local Craft Terminal (LCT)

LCT PIN Assigment for Terminal Operation

Settings for Hyperterminal


Baud Rate: Data Length: Parity Check: Stop Bit: Flow Control: Emulation: Transmission: Hyperterminal: Receiving: 9600 8 None 2 None VT100 Video Terminal Send line ends with line feeds: Yes Local Echo: No CR: No Return on the rigth edge: Yes Force Incoming data to 7-bit ASCII: No