Você está na página 1de 26

IN-LINE MIXED FLOW DUCT FANS

TD-MIXVENT Series
Range of low profile in-line mixed flow duct

TD-MIXVENT

fans manufactured in tough reinforced plastic (from 160 to 800 models) or with metal casing steel finished in a tough epoxy-polyester paint coating(from 1000 to 6000 models). The unique design of the support bracket allows the motor and impeller assembly to be fitted or removed without dismantling the adjacent ducting. Motors

In-Line duct fans

160 2000 models: Motors are IP44, class B, with ball bearings and safety thermal overload protection. Direct 2-speed connection and also suitable for voltage speed control. Electrical supply: Single phase 230V 50/60Hz. 4000 and 6000 models: Motors are IP54, class F, with ball bearings and safety thermal

0 016982 603078

overload protection. Suitable for voltage speed control. Electrical supply: Single phase 230V 50/60Hz. Additional Information MIXVENT TD-T models fitted with a Run-On-Timer adjustable within 1 and 30 minutes and one-speed motor not suitable for speed control.

The MIXVENT-TD fans offer the ideal in-line duct fan solution for a wide range of general residential or commercial ventilation application into.

530

Low profile

Classic centrifugal

In-line centrifugal

Ventilation casing

Mixed flow MIXVENT

The low profile of the MIXVENT-TD fans makes them the most effective solution for installations where the space of installation is limited such as false ceilings.

Easy to mount

Easy maintenance

Fix the support bracket

Place the impeller and motor assembly

The unique design of the support bracket allows the motor and impeller assembly to be fitted or removed without dismantling the adjacent ducting

Carry out the wiring connections

Connect the ducts

Models with Run-On-Timer

Flexible mounting position

MIXVENT-TD-T models (from 160 to 800 models) are fitted with an adjustable timer Can be mounted at any place of the air duct between 1 and 30 minutes and are supplied with a one-speed motor not suitable for speed control

531

In-Line duct fans

TD-MIXVENT

Practical examples of installation of the TD-MIXVENT range

TD-MIXVENT

The MIXVENT-TD range provides a large number of solutions for small and large ventilation installations.

General extract installation

In-Line duct fans

Localised exhaust point installations

Control panel

Workshop

Parkings

Bread oven

Warm air

Drying installations

TD-800/200N

532

Dried fruit hopper

Drying ceramics tunnel

Screen-printing workshop

Hair salon

Meeting room

Catering

Gym

Childrens dinning hall

Waiting room in a health care center

Domestic kitchen extract hood

533

In-Line duct fans

TD-MIXVENT

Residential & Commercial

Design characteristics

TD-MIXVENT

160 Polypropylene casing Steel casing ABS impeller Aluminium impeller Protection class Thermal protection by fuse Self- resetting thermal protection II

250

350

500

800

800N

1000

1300

2000

4000

6000


II


II


II


II


II I

In-Line duct fans

Ball bearings greased for life 1 speed controllable motor 2 speed controllable (*) motor
(*) Models with Run-On-Timer fitted (TD-MIXVENT-T) are not controllable.

Technical characteristics
Speed Maximum power absorbed (W) 20 12
24 18 30 22 50 44 50 44 70 60 120 100 125 85 180 140 255 160 345 665

TD-MIXVENT TD-160/100 N SILENT


NEW

(r.p.m.) 2500 2200


2200 1850 2250 1900 2500 1950 2500 1950 2780 2480 2500 2000 2800 2610 2520 2000 2700 2000 1400 1400

Maximum absorbed current (A) 0,16 0,10


0,11 0,10 0,13 0,10 0,22 0,19 0,22 0,19 0,30 0,26 0,50 0,45 0,50 0,35 0,80 0,60 1,20 0,80 1,53 2,97

Airflow at free discharge (m3/h) 180 140


240 180 360 280 580 430 580 430 880 700 1100 800 1010 900 1300 1100 2000 1550 3800 5500

Maximum operating temperature (C) 40 40


40 40 40 40 60 60 60 60 60 60 60 60 60 60 60 60 60 60 40 40

Sound pressure level* (dB(A)) 24 21


31 26 33 28 33 29 33 29 37 33 39 33 40 38 43 39 47 42 44 44

Duct (mm) 100 100 125 150 160 200 200 250 250 315
355 400

Weight

(kg) 1,4 2,0 2,0 2,7 2,7 4,9 4,9 9,4 9,4
14,0 19,0 26,0

TD - 250/100 TD - 350/125 TD- 500/150 TD- 500/160 TD- 800/200N TD- 800/200 TD-1000/250 TD - 1300/250 TD-2000/315 TD-4000/355 TD-6000/400

*Sound pressure level radiated at 3 m at free air conditions with rigid ducts at the inlet and at the outlet.

Speed

TD-MIXVENT-T
NEW

(r.p.m.) 2500
2200 2250 2500 2500 2500

Maximum power absorbed (W) 20


24 30 50 50 120

Maximum absorbed current (A) 0,16


0,11 0,13 0,22 0,22 0,50

Airflow at free discharge (m3/h) 180


240 360 580 580 1100

Maximum operating temperature (C) 40


40 40 60 60 60

Sound pressure level* (dB(A)) 24


31 33 33 33 39

Duct (mm) 100


100 125 150 160 200

Weight

(kg) 1,4
2,0 2,0 2,7 2,7 4,9

TD-160/100 NT SILENT
TD - 250/100 T TD - 350/125 T TD- 500/ 150 T TD- 500/ 160 T TD- 800/200 T

*Sound pressure level radiated at 3 m at free air conditions with rigid ducts at the inlet and at the outlet.

534

AT INLET
NEW

63 24 28 35 32 32 37 37 35 37 41 40 43 63 24 27 33 25 25 26 29 23 22 29 31 30

125 32 47 47 35 35 42 47 45 52 57 49 56 125 24 46 46 32 32 32 36 34 36 41 49 53

250 39 46 46 55 55 62 61 58 64 66 61 67 250 37 45 46 43 43 48 47 44 39 52 55 59

500 46 53 53 57 57 64 63 66 67 71 66 72 500 34 44 47 39 39 47 46 46 47 55 55 55

1000 52 52 54 59 59 66 68 72 75 77 73 76 1000 36 43 47 44 44 52 54 58 60 64 63 61

2000 49 47 50 62 62 64 67 69 73 74 70 74 2000 41 43 45 53 53 53 57 57 59 63 57 55

4000 40 39 41 56 56 60 64 62 66 67 66 69 4000 32 32 33 42 42 44 48 46 52 57 51 54

8000 21 33 33 48 48 52 54

TD-160/100 N SILENT TD-250/100 TD-350/125 TD-500/150 TD-500/160 TD-800/200N TD-800/200 TD-1000/250 TD-1300/250 TD-2000/315 TD-4000/355 TD-6000/400 RADIATED

61 62 57 60 8000 21 25 24 29 29 31 33 43 47 53 40 45

NEW

TD-160/100 N SILENT TD-250/100 TD-350/125 TD-500/150 TD-500/160 TD-800/200N TD-800/200 TD-1000/250 TD-1300/250 TD-2000/315 TD-4000/355 TD-6000/400

Dimensions (mm)
TD -160/100 N SILENT
NEW

TD -250 to TD-2000

TD -4000 / TD-6000

Model TD - 250/100 TD - 350/125 TD - 500/150 TD - 500/160 TD - 800/200N TD - 800/200 TD -1000/250 TD -1300/250 TD -2000/315 Model TD - 4000/355 TD-6000/400

X 188 188 212 212 232,5 232,5 291 291 356 A 377 407

A 303 258 295 275 302 302 386 386 450 B 238 249 C 451 492

B 176 176 200 200 217 217 272 272 336

C 115 115 127 127 141 141 192 192 224 D 224 267 E 426 487

97 123 147 157 198 198 248 248 312 F 354 399

E 100 100 112 112 124 124 155 155 188 G 150 160 H 368 425

F 90 90 130 130 140 140 168 168 210 I 474 547

G 80 80 80 80 100 100 145 145 182 J 340 370

H 60 60 60 60 94 94 140 140 178 K 8.5 8.5

Accessories (see pages from 549 to 551)


535

In-Line duct fans

54

TD-MIXVENT

Acoustic power spectrum in dB(A), for every frequency band, at the inlet and radiated, at high speed

Performance curves

TD-MIXVENT

HS = High speed Q = Air volume in, m3/hr and m3/s. Pe = Static pressure in mmWG and Pa. LS = Low speed Dry air at 20C and 760 mmHg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985.
Pe mmWG

Pa

In-Line duct fans

HS LS

Pa

Pe mmWG

Pa

Pe mmWG

HS LS LS

HS

Pa

Pe mmWG

Pa

Pe mmWG

HS

HS

LS

LS

536

Performance curves

Pa

Pe mmWG

Pa

Pe mmWG

HS HS LS

LS

Pa

Pe mmWG

Pa

Pe mmWG

HS LS LS

HS

Pa

Pe mmWG

Pa

Pe mmWG

537

In-Line duct fans

TD-MIXVENT

Q = Air volume in, m3/hr and m3/s. Pe = Static pressure in mmWG and Pa. Dry air at 20C and 760 mmHg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985.

In-Line mixed flow duct fans MIXVENT-TD Fan KITS


TD-MIXVENT
The TD ventilation kits enable the simple and fast installation of a complete ventilation system. The kits provide efficient extraction for bathrooms, toilets, washrooms and any other applications that require the removal of bad odours, stuffy and humid air. 3 kits are available: KIT TD-160/100 N SILENT includes: 1 TD-160/100 N SILENT fan
NEW

In-Line duct fans

+ 4 m of flexible aluminium ducting GSA-100 + 1 interior circular air valve BOR-100 + 1 exterior mounted grille GR-100 + 1 adhesive duct tape BA

KIT TD-250/100 includes: 1 TD-250/100 fan


+ 4 m of flexible aluminium ducting GSA-100 + 1 interior circular air valve BOR-100 + 1 exterior mounted grille GR-100 + 1 adhesive duct tape BA

Installation and mounting

KIT TD-250/100T includes: 1 TD-250/100 T fan


+ 4 m of flexible aluminium ducting GSA + 1 interior circular air valve BOR-100 + 1 exterior mounted grille GR-100 + 1 adhesive duct tape BA
BOR-100
TD-160/100 N SILENT TD-250/100 TD-250/100T

GR-100

The TD-250 T extractor is fitted with an adjustable Run-On- Timer between 1 and 30 minutes, keeping the fan in operation for the selected period of time after being switched off.

Accessories included in kit


GSA-100 100 mm diameter of flexible aluminium ducting GR-100 Exterior mounted grille BOR-100 Interior circular air valve

BA-50 Adhesive aluminium duct tape (10 m)

538

In-Line mixed flow duct fans MIXVENT System COMBINATIONS

The MIXVENT System includes a specific different combinations of the MIXVENT TD maintaining the concept that makes the difference: deliver the maximum airflow using the minimum space.

0 025982 603070

MIXVENT-TWIN To double the airflow

MIXVENT-TWINx2 To increase the pressure and double the airflow

539

In-Line duct fans

MIXVENT-TDx2 and MIXVENT-TDx3 To increase the pressure

TD-MIXVENT

range of accessories enabling the installation of

MIXVENT-TDx2
The MIXVENT-TDx2 range consists of two

TD-MIXVENT In-Line duct fans

MIXVENT-TD fans mounted in series to produce almost twice the pressure of the single TD fan. System specially recommended when the fan has the suitable airflow and when an increase of the pressure is required due to the high pressure drops. MIXVENT-TDx2 are standard catalogue products, from 350 to 1300 model. A TDx2 can also be obtained coupling 2 TD model fans using a flange MBR (see the accessories section).

Technical characteristics
Speed Maximum absorbed power (W)
60 44 100 88 140 120 240 200 250 170 360 280

Maximum current (A)


0,26 0,20 0,44 0,38 0,60 0,52 1,00 0,90 1,00 0,70 1,60 1,20

MIXVENT-TDx2
TD x2- 350/125
150 TDx2- 500/ 160

(r.p.m.)
2250 1900 2500 1950 2780 2480 2500 2000 2800 2610 2520 2000

Duty at free discharge (m3/h)


395 320 580 475 880 690 1020 790 1020 900 1320 980

Maximum operating temperature (C)


40 40 60 60 60 60 60 60 60 60 60 60

Sound pressure level* (dB(A))


36 31 48 41 48 44 52 48 57 51 57 52

Weight

(kg)
5,4 5,0 8,7 8,7 18,7 18,7

TDx2- 800/200N TDx2- 800/200 TDx2-1000/250 TDx2- 1300/250

*Sound pressure level radiated at 3 m at free air conditions with rigid ducts at the inlet and at the outlet.

Dimensions (mm)
X E

MIXVENT-TDx2

X 188,0 212,5 212,5 232,5 291,0 291,0

A 417 464 444 500 654 654

C 115 127 127 141 192 192

E 100

F 90

G 253 249 249 298 416 416

H 60 60 60 94 145 145

5,5
C

TDx2-350/125 TDx2-500/150 TDx2-500/160

176 200 200 217 272 272

123 147 147 198 248 248

111,5 130 111,5 130 124 155 155 140 168 168

TDx2-800/200
D B

G A

TDx2-1000/250 TDx2-1300/250

Acoustic power spectrum in dB(A) for every frequency band at the inlet and radiated, at a high speed.
AT THE INLET TDx2-350/125 TDx2-500/150 TDx2-500/160 TDx2-800/200N TDx2-800/200 TDx2-1000/250 TDx2-1300/250 63 41 38 38 43 43 41 43 125 53 41 41 48 53 51 58 250 52 61 61 68 67 64 70 500 59 63 63 70 69 72 73 1000 2000 4000 8000 60 65 65 72 74 78 81 56 68 68 70 73 75 79 47 62 62 66 70 68 72 39 54 54 58 60 60 67 RADIATED TDx2-350/125 TDx2-500/150 TDx2-500/160 TDx2-800/200N TDx2-800/200 TDx2-1000/250 TDx2-1300/250 63 39 31 31 32 35 29 28 125 52 38 38 38 42 40 42 250 52 49 49 54 53 50 45 500 1000 2000 4000 8000 53 45 45 53 52 52 53 53 50 50 58 60 64 66 51 59 59 59 63 63 65 39 48 48 50 54 52 58 30 35 35 37 39 49 53

540

Performance curves

Pa

Pe mmWG

Pa

Pe mmWG

HS

HS

LS

LS

Pa

Pe mmWG

Pa

Pe mmWG

HS HS LS LS

Pa

Pe mmWG

Pa

Pe mmWG

HS HS LS LS

541

In-Line duct fans

TD-MIXVENT

Q = Air volume in, m3/hr and m3/s. HS = High speed Pe = Static pressure in mmWG and Pa. LS = Low speed Dry air at 20C and 760 mmHg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985.

MIXVENT-TDx3
The MIXVENT-TDx3 range consists of a

TD-MIXVENT In-Line duct fans

MIXVENT-TDx2 and MIXVENT-TD fans mounted in series using the flange MBR. System specially recommended when the fan has the suitable airflow and when an important increase of the pressure is required due to the very high pressure drop. Technically more units could be installed in series to increase the pressure but it is recommended to carry out a study before.

MIXVENT-TDx3 design
MIXVENT-TDx3 Composition TDx3-350/125 TDx3-500/150 TDx3-500/160 TDx3-800/200 TDx3-1000/250 TDx3-1300/250 TD-350/125+TDx2-350/125+MBR-350 TD-500/150+TDx2-500/150+MBR-500/150 TD-500/160+TDx2-500/160+MBR-500/160 TD-800/200+TDx2-800/200+MBR-800 TD-1000/250+TDx2-1000/250+MBR-1000 TD-1300/250+TDx2-1300/250+MBR-1000

1 single fan operating

Performance curves

Airflow direction

A must work

MBR flange

Q = Air volume in, m3/hr and m3/s. Pe = Static pressure in mmWG and Pa. Dry air at 20C and 760 mmHg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985.

1 2 3 4 5

TD x 3-350 TD x 3-500 TD x 3-800 TD x 3-1000 TD x 3-1300

MBR flange

2 fans operating

Pe Pa A B C mmWG

MBR flange A and B or A and C must operate

Airflow direction

Dimensions (mm)

G2 A

G1

MIXVENT-TDx3 TD x 3-350/125 TD x 3- 500/150 TD x 3- 500/160 TD x 3- 800/200 TD x 3- 1000/250 TD x 3- 1300/250

A 755 766 726 801 1055 1055

G1 80 80 80 100 145 145

G2 253 249 249 298 416 416

L 213 223 203 207 246 246

542

MIXVENT-TWIN
The MIXVENT-Twin consists of two MIXVENTBase (suitable from 250 to 2000 model). System specially recommended when a large airflow is required (at the same pressure) within a confined space, or where a supplementary airflow is occasionally needed. Once mounted, the whole assembly is ready to be connected to a rectangular duct using the two rectangular flanges supplied with the Kit Twin Base. requires the use of back draft shutters at the discharge (outlet) in order to prevent the air recycling through the stationary fan. It is also needed in installations where it is necessary to mount at the same place, two fans with the same characteristics, for extraction and supply operations.
MIXVENT-TWIN system

MIXVENT-TWIN system with backdraft shutter fitted

Accessories to mount MIXVENT-TWIN system


KIT TWIN BASE-250 + 2 TD -160/100 KIT TWIN BASE-250 + 2 TD 250/100 KIT TWIN BASE-350 + 2 TD -350/125
Backdraft shutter, see accessories page.

KIT TWIN BASE-500/150 + 2 TD-500/150 KIT TWIN BASE-500/160 + 2 TD-500/160 KIT TWIN BASE-800 + 2 TD-800/200

KIT TWIN BASE-1000 + 2 TD-1000/250 KIT TWIN BASE-1000 + 2 TD-1300/250 KIT TWIN BASE-2000 + 2 TD-2000/315

KIT TWIN BASE


This accessory consists of two rectangular duct couplings with standardized dimensions and two supports allowing mounting two TD or two TDx2 fans in parallel.
KIT TWIN BASE KIT TWIN BASE 250 KIT TWIN BASE 350 KIT TWIN BASE 500/150 KIT TWIN BASE 500/160 KIT TWIN BASE 800 KIT TWIN BASE 1000 KIT TWIN BASE 2000 Dimensions (mm) L H 320 180 320 180 395 220 395 220 440 240 540 290 690 355 Nominal dimensions of the rectangular duct (mm) L H 280 140 280 140 355 180 355 180 400 200 500 250 630 315
The independent operation of two MIXVENT-TD requires the use of back draft shutters at the discharge (outlet) in order to prevent the air recycling through the stationary fan.

543

In-Line duct fans

The independent operation of two MIXVENT-TD

TD-MIXVENT

TD fans mounted in parallel using the Kit Twin

Dimensions (mm)

TD-MIXVENT

E B
"

O L

O2 L2

In-Line duct fans

Model Twin-250 Twin-350 Twin-500 (150) Twin-500 (160) Twin-800 Twin-1000 Twin-1300 Twin-2000

A 320 320 395 395 440 540 540 690

B 180 180 220 220 240 290 290 355

C 184 184 206 206 225 282 282 347

D 36 33,5 37 37 37 44 44 53

E 160 160 200 200 220 270 270 335

F 300 300 375 375 420 520 520 650

L 305 305 310 290 317 401 401 451

L2 475 481 461 509 679 679

M 375 333 417 417 456 566 566 699

N 113 91 110 100 103 123 123 136

O 80 80 80 80 100 145 145 182

O2 253 249 249 298 416 416

Performance curves
Q = Air volume in, and Pe = Static pressure in mmWG and Pa. Dry air at 20C and 760 mmHg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985. m3/hr m3/s.

1 2 3 4 5

Twin 350 Twin 500 Twin 800 Twin 1000 Twin 1300

Twin x 2-350 Twin x 2-500 Twin x 2-800 Twin x 2-1000 Twin x 2-1300

Acoustic power spectrum in dB(A) for every frequency band at the inlet and radiated, at a high speed
AT THE INLET TWIN-350/125 TWIN-500/150 TWIN-500/160 TWIN-800/200N 63 38 35 35 40 40 38 40 44 125 50 38 38 45 50 48 55 60 250 49 58 58 65 64 61 67 69 500 56 60 60 67 66 69 70 74 1000 57 62 62 69 71 75 78 80 2000 53 65 65 67 70 72 76 77 4000 44 59 59 63 67 65 69 70 8000 36 51 51 55 57 57 64 65

Pe Pa mmWG TWIN-800/200 TWIN-1000/250 TWIN-1300/250 TWIN-2000/315

RADIATED TWIN-350/125 TWIN-500/150 TWIN-500/160 TWIN-800/200N TWIN-800/200 TWIN-1000/250 TWIN-1300/250 TWIN-2000/315

63 36 28 28 29 32 26 25 32

125 49 35 35 35 39 37 39 44

250 49 46 46 51 50 47 42 55

500 50 42 42 50 49 49 50 58

1000 50 47 47 55 57 61 63 67

2000 48 56 56 56 60 60 62 66

4000 36 45 45 47 51 49 55 60

8000 27 32 32 34 36 46 50 56

544

MIXVENT-TWINx2
The MIXVENT-Twinx2 consists of two the Kit Twin Base (suitable from 350 to 1300 model). System specially recommended when a large airflow is required (at the same pressure) within a confined space, or where a supplementary airflow is occasionally needed. Once mounted, the whole assembly is ready to be connected to a rectangular duct using the two rectangular flanges supplied with the Kit Twin Base. MIXVENT-TDx2 requires the use of back draft shutters at the discharge (outlet) in order to prevent the air recycling through the stationary fan. The independent operation of two
MIXVENT-TWINx2 system

Elements to mount MIXVENT-TWIN x 2 system


KIT KIT KIT KIT KIT KIT TWIN TWIN TWIN TWIN TWIN TWIN BASE-350 + 2 TDx2-350/125 BASE-500/150 + 2 TDx2-500/150 BASE-500/160 + 2 TDx2-500/160 BASE-800 + 2 TDx2-800/200 BASE-1000 + 2 TDx2-1000/250 BASE-1000 + 2 TDx2-1300/250

MIXVENT-TWINx2 system with backdraft shutter fitted

Performance curves
Q = Air volume in, m3/hr and m3/s. Pe = Static pressure in mmWG and Pa. Dry air at 20C and 760 mmHg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985.

1 2 3 4 5

Twin 350 Twin 500 Twin 800 Twin 1000 Twin 1300

Twin x 2-350 Twin x 2-500 Twin x 2-800 Twin x 2-1000 Twin x 2-1300

Backdraft shutter, see accessories page.

KIT TWIN BASE


This accessory consists of two rectangular duct couplings with standardized dimensions and two supports allowing mounting two TD or two TDx2 fans in parallel.
Pe Pa mmWG

KIT TWIN BASE

Dimensions (mm) L H 180 180 220 220 240 290 355

Nominal dimensions of the rectangular duct (mm) L 280 280 355 355 400 500 630 H 140 140 180 180 200 250 315

KIT TWIN BASE 250 KIT TWIN BASE 350 KIT TWIN BASE 500/150 KIT TWIN BASE 500/160 KIT TWIN BASE 800 KIT TWIN BASE 1000 KIT TWIN BASE 2000

320 320 395 395 440 540 690

Due to the isolated operation of TD models, backdraft shutters mounted at the outlet of TD fans are required in order to avoid the backdraft of air when the fan is not operating.

545

In-Line duct fans

TD-MIXVENT

MIXVENT-TDx2 fans mounted in parallel using

HELICAL CENTRIFUGAL VENTILATORS WITH CONTINUOUS CURRENT MOTOR

TD-ECOWATT Series
TD ECOWATT

NEW

In-Line duct fans

Range of Low Profile Mixed flow fans with ball bearings and brushless DC motors, of high efficiency and low consumption. Manufactured in plastic, removable fan body, and rated as standard 90/260V-50/60Hz,IP44, speed controllable from 10% to 100%. Specially suitable for any kind of ventilation application, where the fan must operate continuously allowing a very important energy saving, or on those requiring a Demand Controlled Ventilaton System i nvolving the use of other sensors or controls

Low profile

Classic Centrifugal

Centrfugal In-line

Ventilation cabinet

Mixed flow TD-ECOWATT

The low profile of the TD-ECOWATT fans makes them the most effective solution for installations where the space of installation is limited such as false ceilings.

546

Easy to mount

Easy maintenance

Fix the support bracket

Place the impeller and motor assembly

The unique design of the support bracket allows the motor and impeller assembly to be fitted or removed without dismantling the adjacent ducting

Carry out the wiring connections

Connect the ducts

Flexible mounting position Continuous current motor

Electronics totally integrated in the product

Continuous current brushless motor, high performance and low consumption, adjustable in lineal form

Can be mounted at any place of the air duct

Design characteristics
160 Plastic housing Plastic impeller Insulation Class Non self resetable thermal protection Ball bearings II 250 II 350 II 500 II 800 II

Technical characteristics
Speed Maximum power absorbed (W) 10 22 22 48 105 Maximum absorbed current (A) 0,07 0,17 0,17 0,35 0,75 Airflow at free discharge (m3/h) 190 275 360 580 1030 Maximum operating temperature (C) 60 60 60 60 60 Sound pressure level* (dB(A)) 34 35 34 36 38 Duct (mm) 100 100 125 150 200 Weight

TD-MIXVENT TD-160/100 ECOWATT TD-250/100 ECOWATT TD-350/125 ECOWATT TD-500/150 ECOWATT TD-800/200 ECOWATT

(r.p.m.) 2650 2400 2420 2600 2360

(kg) 1,4 2,0 2,0 2,7 4,9

547

In-Line duct fans

TD ECOWATT

Sound characteristics

TD ECOWATT

Sound Power Spectrum in dB(A), per band of frequency, at inlet, outlet or radiated, for working points low (B), medium(M) or high (A) on every fan curve. Tests made according to SO 13347-3 004.
TD-160/100 ECOWATT B INLET M A B OUTLET M A B RADIATED M A TD-250/100 ECOWATT B INLET M A B OUTLET M A B RADIATED M A TD-350/125 ECOWATT B INLET M A B OUTLET M A B RADIATED M A 63 30 31 36 29 30 32 24 25 30 26 27 28 32 29 29 23 24 25 24 28 29 32 29 31 18 22 23 125 31 32 37 29 30 36 31 32 37 32 32 33 33 32 33 29 29 30 29 28 35 33 30 35 20 19 26 250 43 44 47 40 39 40 43 44 47 44 46 46 45 47 49 44 46 46 44 44 50 46 45 50 44 44 50 500 50 51 54 51 52 54 47 48 51 57 55 54 56 56 53 50 48 47 52 52 53 56 55 56 42 42 43 1.000 2.000 4.000 8.000 58 58 44 34 56 57 42 33 56 59 41 31 56 56 45 34 56 56 43 33 55 53 43 33 46 52 38 25 44 51 36 24 44 53 35 22 55 55 55 53 52 50 50 50 50 55 53 55 55 53 52 48 46 48 53 53 53 53 52 51 50 50 50 54 52 55 54 52 52 50 48 51 45 44 44 44 43 41 39 38 38 44 44 45 43 43 42 36 36 37 36 36 36 36 35 33 29 29 29 33 35 35 34 34 33 23 25 25 GLOBAL 61 60 62 60 60 59 54 54 56 60 60 59 59 59 57 55 55 55 59 58 60 60 59 59 53 52 55 TD-500/150 ECOWATT B M INLET A B M OUTLET A B M RADIATED A TD-800/200 ECOWATT B M INLET A B M OUTLET A B M RADIATED A 63 26 26 26 34 29 31 18 18 18 27 26 36 48 40 36 27 26 36 125 36 34 37 36 34 34 24 22 25 35 33 47 47 39 43 22 20 34 250 53 50 53 56 51 55 51 48 51 51 49 63 51 49 61 41 39 53 500 56 55 58 61 60 65 37 36 39 55 54 64 61 62 68 36 35 45 1.000 2.000 4.000 8.000 58 64 58 50 57 61 55 48 59 61 56 48 62 62 57 50 61 59 55 48 62 59 56 49 45 55 43 35 44 52 40 33 46 52 41 33 66 65 66 65 65 67 54 53 54 66 63 63 67 65 65 56 53 53 61 59 59 62 59 60 48 46 46 51 49 51 50 48 51 33 31 33 GLOBAL 67 64 65 67 66 68 57 54 55 70 68 71 71 69 72 59 57 59

In-Line duct fans

Dimensions (mm)
211 111.5

273

173,5

80 295

147 200

TD-160/100 ECOWATT
X
5. 5

TD-500/150 ECOWATT
233

124

C
94

.5

G A

D B

100 302

198 217

TD-250/100 and TD-350/125 ECOWATT


Model X A 303 258 B 176 176 C 156 156 D 97 123 E 100 100 F 90 90 G 80 80 H 60 60 TD-250/100 ECOWATT 188 TD-350/125 ECOWATT 188

TD-800/200 ECOWATT

548

140

293

184

130

60

5 5.

Characteristic curves
Q = Air volume in, m3/hr and m3/s. Pe = Static pressure in mmWG and Pa. Dry air at 20C and 760 mmHg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985.
Pa Pe mmWG

Pa

Pe mmWG

Pa

Pe mmWG

Pa

Pe mmWG

Pa

Pe mmWG

549

In-Line duct fans

TD ECOWATT

MIXVENT HEATING System (MIXVENT-TD + MBE heater battery)


TD-MIXVENT In-Line duct fans
The MIXVENT heating system offers the most economic solution for the heating of fresh air supply systems. The MIXVENT HEATING system consists on a MBE electric heater battery installed on the discharge side of the MIXVENT-TD fan. The minimum air velocity through the heater batteries must be 2 m/s. The batteries incorporate: - Insulated element rods. - Automatic overheat thermostat wired in series with an additional safety overheat manual reset thermostat (RESET). Units are available for single phase (models 100, 125 and 160) or three phase (other models) electrical supply connection, with a circuit protection supplied on 230V single phase. - Connection box IP43. A range of duct or ambient temperature sensors and controllers accessories to accompany the electrical heater battery are available. These controller accessories modulate the heater output as a function of the required environmental temperature. With this system it is possible to achieve temperature rise up to 50 on the supply air.
1000-1300/250 2000/315 4000/355 6000/400 MBE-250/60T MBE-315/90T MBE-355/90T MBE-400/120T 6000 9000 9000 12000 2/400 3/400 3/400 3/400 350 560 710 900 PULSER TTC-2000 TTC-2000 TTC-2000 TD-MIXVENT MBE battery type Battery power (W) 400 1200 2100 5000 Batteries supply Minimum airflow (m3/s) 60 90 150 230 Speed controller type PULSER PULSER PULSER PULSER

TD-MIXVENT

MBE Electrical heater battery

0 026082 603076

250/100 350/125 500/160 800/200

MBE-100/04B MBE-125/12B MBE-160/21B MBE-200/50T

1/230 1/230 1/230 2/400

SELECTION EXAMPLE DATA: Airflow: 700 m3/h (Q) Input air temperature: +5 C Required output temperature: +27 C In those installations where MIXVENT HEATING system is required it is convenient to use filter boxes MFL to protect the electrical P = Q x 0,36 x T = 700 x 0,36 x 22 = 5544 W batteries from the debris.

REQUIRED HEAT POWER:

BATTERY ELECTION Or: MBE-200/50T Or: MBE-250/60T Final election will depend of: Total pressure drop Desired sound level Available space

Difference of temperature between external and internal air T (C)

550

Dimensions (mm)

MBE heater batteries accessories


PULSER controller Electronic controller to regulate the heat output for single phase or two phase (200 415 V) electric heater battery in order to maintain a constant pre-selected temperature. Depending on the selected temperature, the controller pulses the entire power output and uses a time-proportional control to maintain that temperature. PULSER incorporates a built-in temperature sensor and can de installed directly in the room to heat. External temperature sensors can be also connected. TTC-2000 controller Electronic controller to regulate the heat output for three phase electrical heater batteries up to 16.5kW in order to maintain a constant pre-selected temperature. Depending on the selected temperature, the controller pulses the entire power output and uses a time-proportional control to maintain that temperature. TTC-2000 is designed to be mounted within a main electrical board and has to be connected to a temperature sensor placed in the room to heat or in the warm air supply ducting.

Dimensions LxAxH (mm): 92x45x150

Dimensions LxAxH (mm): 160x140x280

Room temperature sensor TG-R530 To place in the room to heat: NTC type with linear scale Operating temperature: 0 -30C IP-20 Suitable for controller type TTC-2000.

Duct temperature sensor TG-K330 Temperature sensor to place in the warm air supply ducting. NTC type with linear scale Operating temperature: 0 -30C IP-20 Suitable for controllers type PULSER and TTC-2000.

Dimensions LxAxH (mm): 70x30x70


5 30 40
9

140

551

In-Line duct fans

TD-MIXVENT

Battery pressure drop p (Pa)

MIXVENT FILTER System (TD-MIXVENT + Filtration box MFL)


TD-MIXVENT
The MIXVENT HEATING system consists on a MFL filtration box installed on the inlet side of the MIXVENT-TD fan and are used when the installation requires supplying filtered clean air. MFL filtration boxes are of EU4 grade filtration and are designed for direct connection with standard circular ducting.

In-Line duct fans

TD-MIXVENT Filter box MFL

A usual application of MFL filtration boxes is to protect the electrical heater batteries from the dirt, in installations where MIXVENT HEATING system is used.

0 026182 603075

Dimensions (mm)
E F

D B

The MFL filtration boxes are supplied with a cover easily removable to replace the filter.

Model MFL-100 MFL-125 MFL-160 MFL-200 MFL-250 MFL-315 MFL-355 MFL-400

A 200 200 200 243 293 342 447 447

B 200 200 200 244 294 343 448 448

D 100 125 160 200 250 315 355 400

E 160 160 154 154 154 154 154 154

F 196 196 196 202 206 206 254 254

Pressure drop of the filter boxes p (Pa)

552

TD-MIXVENT Installation accessories


Specific accessories for TD Series
MCA Back-draft shutters mounted at the outlet of the fans, to prevent external air entry and to limit heat leakage, when the fan are not in use. To apply with TD, TDx2, TDx3 and TWIN models.
B D

A C

MCA-250 to 2000 Model MCA/JCA MCA - 250 MCA - 350 MCA - 500/150 MCA - 500/160 MCA - 800 MCA - 1000 MCA - 2000 MCA - 4000 MCA - 6000 Type of TD - TDx2 - TDx3 - TWIN 160/100N - 250/100 350/125 500/150 500/160 800/200 - 800/200N 1000/250 - 1300/250 2000/315 4000/355 6000/400 Model MCA MCA - 250 MCA - 350 MCA - 500/150 MCA - 500/160 MCA - 800 MCA - 1000 MCA - 2000 MCA - 4000 MCA - 6000 A 107 107 121 121 131,5 164 205 265 307

MCA-4000/6000 B 111 136 163,5 173,5 214 264,5 330 374 419 C 31,5 31,5 35 35 35 42 50 55 65 D 94,5 119,5 147 157 197,5 248 312 354 399

MAR Rectangular Duct Adapters enable TD, TDx2 and TDx3 to be connected to rectangular ducting.

F A C

C 33,3 33,5 37 37 37 42 52 E 160 160 200 200 220 270 355

Model MAR

Type of TD-TDx2-TDx3

Nominal dim. of ducting L x H


224 x 140 224 x 140 280 x 180 280 x 180 315 x 200 400 x 250 500 X 315

Model MAR MAR - 250 MAR - 350 MAR - 500/150 MAR - 500/160 MAR - 800 MAR - 1000 MAR - 2000

A 264 264 320 320 355 440 540

B 180 180 220 220 240 290 355

F 244 244 300 300 335 420 520

G 9 9 9 9 9 9 9

MAR - 250 160/100N - 250/100 MAR - 350 350/125 MAR - 500/150 500/150 MAR - 500/160 500/160 MAR - 800 800/200-800/200N MAR - 1000 1000/250-1300/250 MAR - 2000 2000/315

MRJ Grilles mounted at the inlet or outlet of the fan, to prevent the entry of any foreign objects that could damage the fan. To apply with TD, TD x 2, TD x 3 and TWIN models.

Model MRJ MRJ - 250 MRJ - 350 MRJ - 500/150 MRJ - 500/160 MRJ - 800 MRJ - 1000 MRJ - 2000 MRJ - 4000 MRJ - 6000

Type of TD - TDx2 - TDx3 - TWIN 160/100N - 250/100 350/125 500/150 500/160 800/200 - 800/200N 1000/250 - 1300/250 2000/315 4000/355 6000/400

553

In-Line duct fans

TD-MIXVENT

TD-MIXVENT

MBR Flanges allowing the coupling of TD fans in series.

Model MBR MBR-350 MBR-500/150 MBR-500/160 MBR-800 MBR-1000

of the duct 125 150 160 200 250

In-Line duct fans

KIT TWIN BASE This accessory consists of two rectangular duct couplings with standardized dimensions and two supports allowing mounting two TD or two TDx2 fans in parallel.

KIT TWIN BASE KIT TWIN BASE 250 KIT TWIN BASE 350 KIT TWIN BASE 500/150 KIT TWIN BASE 500/160 KIT TWIN BASE 800 KIT TWIN BASE 1000 KIT TWIN BASE 2000

Dimensions (mm) L 320 320 395 395 440 540 690 H 180 180 220 220 240 290 355

Nominal dim. of rectangular duct (mm) L 280 280 355 355 400 500 630 H 140 140 180 180 200 250 315

Due to the independent operation of TD models, backdraft shutters mounted at the outlet of TD fans are required in order to avoid the backdraft of air when the fan is disconnected.

SIL Sound attenuators

"

Model SIL 125 SIL 160 SIL 200 SIL 250 SIL 315 SIL 355 SIL 400

A (mm) 125 160 200 250 315 355 400

B (mm) 250 250 315 355 400 450 500

C (mm) 700 700 700 700 700 700 700

D (mm) 900 900 900 900 860 860 860

Attenuation in dB 63 2 2 2 2 2 3,7 1,8 125 5 9 8 6 2,2 4,1 3,1 250 13 14 11 10 3,3 6,7 4 500 21 23 23 19 9 13,2 9,5 1000 37 25 25 25 21,2 14,3 13,7 2000 37 16 17 16 7,6 3,4 5,6 4000 31 11 9 7 4,1 8,1 0,4 8000 9 6 4 3 5,5 7 5,9

SIL sound attenuator mounted together with a TD-MIXVENT, a filter box MFL and a heat electrical battery MBE

554

General installation accessories


GSA Flexible aluminium ducting GSI Flexible acoustic ducting CX Worm drive clips

PER-W Outdoor plastic louvre shutters

BOC Circular air valves

RED Reducer

MRT Joining pieces

CT Roof terminal kits

GRA Aluminium external grilles

GRI Internal extract grilles

RP Terminal connectors for GRI internal grilles

GCI Interior circular grilles

Electrical accessories
REGUL 2 2 Speed switch REB Single-phase electronic speed controller RMB Single-phase auto-transformer speed controller

555

In-Line duct fans

TD-MIXVENT

Você também pode gostar