Escolar Documentos
Profissional Documentos
Cultura Documentos
TD-MIXVENT Series
Range of low profile in-line mixed flow duct
TD-MIXVENT
fans manufactured in tough reinforced plastic (from 160 to 800 models) or with metal casing steel finished in a tough epoxy-polyester paint coating(from 1000 to 6000 models). The unique design of the support bracket allows the motor and impeller assembly to be fitted or removed without dismantling the adjacent ducting. Motors
160 2000 models: Motors are IP44, class B, with ball bearings and safety thermal overload protection. Direct 2-speed connection and also suitable for voltage speed control. Electrical supply: Single phase 230V 50/60Hz. 4000 and 6000 models: Motors are IP54, class F, with ball bearings and safety thermal
0 016982 603078
overload protection. Suitable for voltage speed control. Electrical supply: Single phase 230V 50/60Hz. Additional Information MIXVENT TD-T models fitted with a Run-On-Timer adjustable within 1 and 30 minutes and one-speed motor not suitable for speed control.
The MIXVENT-TD fans offer the ideal in-line duct fan solution for a wide range of general residential or commercial ventilation application into.
530
Low profile
Classic centrifugal
In-line centrifugal
Ventilation casing
The low profile of the MIXVENT-TD fans makes them the most effective solution for installations where the space of installation is limited such as false ceilings.
Easy to mount
Easy maintenance
The unique design of the support bracket allows the motor and impeller assembly to be fitted or removed without dismantling the adjacent ducting
MIXVENT-TD-T models (from 160 to 800 models) are fitted with an adjustable timer Can be mounted at any place of the air duct between 1 and 30 minutes and are supplied with a one-speed motor not suitable for speed control
531
TD-MIXVENT
TD-MIXVENT
The MIXVENT-TD range provides a large number of solutions for small and large ventilation installations.
Control panel
Workshop
Parkings
Bread oven
Warm air
Drying installations
TD-800/200N
532
Screen-printing workshop
Hair salon
Meeting room
Catering
Gym
533
TD-MIXVENT
Design characteristics
TD-MIXVENT
160 Polypropylene casing Steel casing ABS impeller Aluminium impeller Protection class Thermal protection by fuse Self- resetting thermal protection II
250
350
500
800
800N
1000
1300
2000
4000
6000
II
II
II
II
II I
Ball bearings greased for life 1 speed controllable motor 2 speed controllable (*) motor
(*) Models with Run-On-Timer fitted (TD-MIXVENT-T) are not controllable.
Technical characteristics
Speed Maximum power absorbed (W) 20 12
24 18 30 22 50 44 50 44 70 60 120 100 125 85 180 140 255 160 345 665
Duct (mm) 100 100 125 150 160 200 200 250 250 315
355 400
Weight
(kg) 1,4 2,0 2,0 2,7 2,7 4,9 4,9 9,4 9,4
14,0 19,0 26,0
TD - 250/100 TD - 350/125 TD- 500/150 TD- 500/160 TD- 800/200N TD- 800/200 TD-1000/250 TD - 1300/250 TD-2000/315 TD-4000/355 TD-6000/400
*Sound pressure level radiated at 3 m at free air conditions with rigid ducts at the inlet and at the outlet.
Speed
TD-MIXVENT-T
NEW
(r.p.m.) 2500
2200 2250 2500 2500 2500
Weight
(kg) 1,4
2,0 2,0 2,7 2,7 4,9
TD-160/100 NT SILENT
TD - 250/100 T TD - 350/125 T TD- 500/ 150 T TD- 500/ 160 T TD- 800/200 T
*Sound pressure level radiated at 3 m at free air conditions with rigid ducts at the inlet and at the outlet.
534
AT INLET
NEW
63 24 28 35 32 32 37 37 35 37 41 40 43 63 24 27 33 25 25 26 29 23 22 29 31 30
125 32 47 47 35 35 42 47 45 52 57 49 56 125 24 46 46 32 32 32 36 34 36 41 49 53
250 39 46 46 55 55 62 61 58 64 66 61 67 250 37 45 46 43 43 48 47 44 39 52 55 59
500 46 53 53 57 57 64 63 66 67 71 66 72 500 34 44 47 39 39 47 46 46 47 55 55 55
1000 52 52 54 59 59 66 68 72 75 77 73 76 1000 36 43 47 44 44 52 54 58 60 64 63 61
2000 49 47 50 62 62 64 67 69 73 74 70 74 2000 41 43 45 53 53 53 57 57 59 63 57 55
4000 40 39 41 56 56 60 64 62 66 67 66 69 4000 32 32 33 42 42 44 48 46 52 57 51 54
8000 21 33 33 48 48 52 54
TD-160/100 N SILENT TD-250/100 TD-350/125 TD-500/150 TD-500/160 TD-800/200N TD-800/200 TD-1000/250 TD-1300/250 TD-2000/315 TD-4000/355 TD-6000/400 RADIATED
61 62 57 60 8000 21 25 24 29 29 31 33 43 47 53 40 45
NEW
TD-160/100 N SILENT TD-250/100 TD-350/125 TD-500/150 TD-500/160 TD-800/200N TD-800/200 TD-1000/250 TD-1300/250 TD-2000/315 TD-4000/355 TD-6000/400
Dimensions (mm)
TD -160/100 N SILENT
NEW
TD -250 to TD-2000
TD -4000 / TD-6000
Model TD - 250/100 TD - 350/125 TD - 500/150 TD - 500/160 TD - 800/200N TD - 800/200 TD -1000/250 TD -1300/250 TD -2000/315 Model TD - 4000/355 TD-6000/400
X 188 188 212 212 232,5 232,5 291 291 356 A 377 407
A 303 258 295 275 302 302 386 386 450 B 238 249 C 451 492
C 115 115 127 127 141 141 192 192 224 D 224 267 E 426 487
97 123 147 157 198 198 248 248 312 F 354 399
E 100 100 112 112 124 124 155 155 188 G 150 160 H 368 425
54
TD-MIXVENT
Acoustic power spectrum in dB(A), for every frequency band, at the inlet and radiated, at high speed
Performance curves
TD-MIXVENT
HS = High speed Q = Air volume in, m3/hr and m3/s. Pe = Static pressure in mmWG and Pa. LS = Low speed Dry air at 20C and 760 mmHg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985.
Pe mmWG
Pa
HS LS
Pa
Pe mmWG
Pa
Pe mmWG
HS LS LS
HS
Pa
Pe mmWG
Pa
Pe mmWG
HS
HS
LS
LS
536
Performance curves
Pa
Pe mmWG
Pa
Pe mmWG
HS HS LS
LS
Pa
Pe mmWG
Pa
Pe mmWG
HS LS LS
HS
Pa
Pe mmWG
Pa
Pe mmWG
537
TD-MIXVENT
Q = Air volume in, m3/hr and m3/s. Pe = Static pressure in mmWG and Pa. Dry air at 20C and 760 mmHg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985.
+ 4 m of flexible aluminium ducting GSA-100 + 1 interior circular air valve BOR-100 + 1 exterior mounted grille GR-100 + 1 adhesive duct tape BA
GR-100
The TD-250 T extractor is fitted with an adjustable Run-On- Timer between 1 and 30 minutes, keeping the fan in operation for the selected period of time after being switched off.
538
The MIXVENT System includes a specific different combinations of the MIXVENT TD maintaining the concept that makes the difference: deliver the maximum airflow using the minimum space.
0 025982 603070
539
TD-MIXVENT
MIXVENT-TDx2
The MIXVENT-TDx2 range consists of two
MIXVENT-TD fans mounted in series to produce almost twice the pressure of the single TD fan. System specially recommended when the fan has the suitable airflow and when an increase of the pressure is required due to the high pressure drops. MIXVENT-TDx2 are standard catalogue products, from 350 to 1300 model. A TDx2 can also be obtained coupling 2 TD model fans using a flange MBR (see the accessories section).
Technical characteristics
Speed Maximum absorbed power (W)
60 44 100 88 140 120 240 200 250 170 360 280
MIXVENT-TDx2
TD x2- 350/125
150 TDx2- 500/ 160
(r.p.m.)
2250 1900 2500 1950 2780 2480 2500 2000 2800 2610 2520 2000
Weight
(kg)
5,4 5,0 8,7 8,7 18,7 18,7
*Sound pressure level radiated at 3 m at free air conditions with rigid ducts at the inlet and at the outlet.
Dimensions (mm)
X E
MIXVENT-TDx2
E 100
F 90
H 60 60 60 94 145 145
5,5
C
111,5 130 111,5 130 124 155 155 140 168 168
TDx2-800/200
D B
G A
TDx2-1000/250 TDx2-1300/250
Acoustic power spectrum in dB(A) for every frequency band at the inlet and radiated, at a high speed.
AT THE INLET TDx2-350/125 TDx2-500/150 TDx2-500/160 TDx2-800/200N TDx2-800/200 TDx2-1000/250 TDx2-1300/250 63 41 38 38 43 43 41 43 125 53 41 41 48 53 51 58 250 52 61 61 68 67 64 70 500 59 63 63 70 69 72 73 1000 2000 4000 8000 60 65 65 72 74 78 81 56 68 68 70 73 75 79 47 62 62 66 70 68 72 39 54 54 58 60 60 67 RADIATED TDx2-350/125 TDx2-500/150 TDx2-500/160 TDx2-800/200N TDx2-800/200 TDx2-1000/250 TDx2-1300/250 63 39 31 31 32 35 29 28 125 52 38 38 38 42 40 42 250 52 49 49 54 53 50 45 500 1000 2000 4000 8000 53 45 45 53 52 52 53 53 50 50 58 60 64 66 51 59 59 59 63 63 65 39 48 48 50 54 52 58 30 35 35 37 39 49 53
540
Performance curves
Pa
Pe mmWG
Pa
Pe mmWG
HS
HS
LS
LS
Pa
Pe mmWG
Pa
Pe mmWG
HS HS LS LS
Pa
Pe mmWG
Pa
Pe mmWG
HS HS LS LS
541
TD-MIXVENT
Q = Air volume in, m3/hr and m3/s. HS = High speed Pe = Static pressure in mmWG and Pa. LS = Low speed Dry air at 20C and 760 mmHg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985.
MIXVENT-TDx3
The MIXVENT-TDx3 range consists of a
MIXVENT-TDx2 and MIXVENT-TD fans mounted in series using the flange MBR. System specially recommended when the fan has the suitable airflow and when an important increase of the pressure is required due to the very high pressure drop. Technically more units could be installed in series to increase the pressure but it is recommended to carry out a study before.
MIXVENT-TDx3 design
MIXVENT-TDx3 Composition TDx3-350/125 TDx3-500/150 TDx3-500/160 TDx3-800/200 TDx3-1000/250 TDx3-1300/250 TD-350/125+TDx2-350/125+MBR-350 TD-500/150+TDx2-500/150+MBR-500/150 TD-500/160+TDx2-500/160+MBR-500/160 TD-800/200+TDx2-800/200+MBR-800 TD-1000/250+TDx2-1000/250+MBR-1000 TD-1300/250+TDx2-1300/250+MBR-1000
Performance curves
Airflow direction
A must work
MBR flange
Q = Air volume in, m3/hr and m3/s. Pe = Static pressure in mmWG and Pa. Dry air at 20C and 760 mmHg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985.
1 2 3 4 5
MBR flange
2 fans operating
Pe Pa A B C mmWG
Airflow direction
Dimensions (mm)
G2 A
G1
542
MIXVENT-TWIN
The MIXVENT-Twin consists of two MIXVENTBase (suitable from 250 to 2000 model). System specially recommended when a large airflow is required (at the same pressure) within a confined space, or where a supplementary airflow is occasionally needed. Once mounted, the whole assembly is ready to be connected to a rectangular duct using the two rectangular flanges supplied with the Kit Twin Base. requires the use of back draft shutters at the discharge (outlet) in order to prevent the air recycling through the stationary fan. It is also needed in installations where it is necessary to mount at the same place, two fans with the same characteristics, for extraction and supply operations.
MIXVENT-TWIN system
KIT TWIN BASE-500/150 + 2 TD-500/150 KIT TWIN BASE-500/160 + 2 TD-500/160 KIT TWIN BASE-800 + 2 TD-800/200
KIT TWIN BASE-1000 + 2 TD-1000/250 KIT TWIN BASE-1000 + 2 TD-1300/250 KIT TWIN BASE-2000 + 2 TD-2000/315
543
TD-MIXVENT
Dimensions (mm)
TD-MIXVENT
E B
"
O L
O2 L2
Model Twin-250 Twin-350 Twin-500 (150) Twin-500 (160) Twin-800 Twin-1000 Twin-1300 Twin-2000
D 36 33,5 37 37 37 44 44 53
Performance curves
Q = Air volume in, and Pe = Static pressure in mmWG and Pa. Dry air at 20C and 760 mmHg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985. m3/hr m3/s.
1 2 3 4 5
Twin 350 Twin 500 Twin 800 Twin 1000 Twin 1300
Twin x 2-350 Twin x 2-500 Twin x 2-800 Twin x 2-1000 Twin x 2-1300
Acoustic power spectrum in dB(A) for every frequency band at the inlet and radiated, at a high speed
AT THE INLET TWIN-350/125 TWIN-500/150 TWIN-500/160 TWIN-800/200N 63 38 35 35 40 40 38 40 44 125 50 38 38 45 50 48 55 60 250 49 58 58 65 64 61 67 69 500 56 60 60 67 66 69 70 74 1000 57 62 62 69 71 75 78 80 2000 53 65 65 67 70 72 76 77 4000 44 59 59 63 67 65 69 70 8000 36 51 51 55 57 57 64 65
63 36 28 28 29 32 26 25 32
125 49 35 35 35 39 37 39 44
250 49 46 46 51 50 47 42 55
500 50 42 42 50 49 49 50 58
1000 50 47 47 55 57 61 63 67
2000 48 56 56 56 60 60 62 66
4000 36 45 45 47 51 49 55 60
8000 27 32 32 34 36 46 50 56
544
MIXVENT-TWINx2
The MIXVENT-Twinx2 consists of two the Kit Twin Base (suitable from 350 to 1300 model). System specially recommended when a large airflow is required (at the same pressure) within a confined space, or where a supplementary airflow is occasionally needed. Once mounted, the whole assembly is ready to be connected to a rectangular duct using the two rectangular flanges supplied with the Kit Twin Base. MIXVENT-TDx2 requires the use of back draft shutters at the discharge (outlet) in order to prevent the air recycling through the stationary fan. The independent operation of two
MIXVENT-TWINx2 system
Performance curves
Q = Air volume in, m3/hr and m3/s. Pe = Static pressure in mmWG and Pa. Dry air at 20C and 760 mmHg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985.
1 2 3 4 5
Twin 350 Twin 500 Twin 800 Twin 1000 Twin 1300
Twin x 2-350 Twin x 2-500 Twin x 2-800 Twin x 2-1000 Twin x 2-1300
Nominal dimensions of the rectangular duct (mm) L 280 280 355 355 400 500 630 H 140 140 180 180 200 250 315
KIT TWIN BASE 250 KIT TWIN BASE 350 KIT TWIN BASE 500/150 KIT TWIN BASE 500/160 KIT TWIN BASE 800 KIT TWIN BASE 1000 KIT TWIN BASE 2000
Due to the isolated operation of TD models, backdraft shutters mounted at the outlet of TD fans are required in order to avoid the backdraft of air when the fan is not operating.
545
TD-MIXVENT
TD-ECOWATT Series
TD ECOWATT
NEW
Range of Low Profile Mixed flow fans with ball bearings and brushless DC motors, of high efficiency and low consumption. Manufactured in plastic, removable fan body, and rated as standard 90/260V-50/60Hz,IP44, speed controllable from 10% to 100%. Specially suitable for any kind of ventilation application, where the fan must operate continuously allowing a very important energy saving, or on those requiring a Demand Controlled Ventilaton System i nvolving the use of other sensors or controls
Low profile
Classic Centrifugal
Centrfugal In-line
Ventilation cabinet
The low profile of the TD-ECOWATT fans makes them the most effective solution for installations where the space of installation is limited such as false ceilings.
546
Easy to mount
Easy maintenance
The unique design of the support bracket allows the motor and impeller assembly to be fitted or removed without dismantling the adjacent ducting
Continuous current brushless motor, high performance and low consumption, adjustable in lineal form
Design characteristics
160 Plastic housing Plastic impeller Insulation Class Non self resetable thermal protection Ball bearings II 250 II 350 II 500 II 800 II
Technical characteristics
Speed Maximum power absorbed (W) 10 22 22 48 105 Maximum absorbed current (A) 0,07 0,17 0,17 0,35 0,75 Airflow at free discharge (m3/h) 190 275 360 580 1030 Maximum operating temperature (C) 60 60 60 60 60 Sound pressure level* (dB(A)) 34 35 34 36 38 Duct (mm) 100 100 125 150 200 Weight
TD-MIXVENT TD-160/100 ECOWATT TD-250/100 ECOWATT TD-350/125 ECOWATT TD-500/150 ECOWATT TD-800/200 ECOWATT
547
TD ECOWATT
Sound characteristics
TD ECOWATT
Sound Power Spectrum in dB(A), per band of frequency, at inlet, outlet or radiated, for working points low (B), medium(M) or high (A) on every fan curve. Tests made according to SO 13347-3 004.
TD-160/100 ECOWATT B INLET M A B OUTLET M A B RADIATED M A TD-250/100 ECOWATT B INLET M A B OUTLET M A B RADIATED M A TD-350/125 ECOWATT B INLET M A B OUTLET M A B RADIATED M A 63 30 31 36 29 30 32 24 25 30 26 27 28 32 29 29 23 24 25 24 28 29 32 29 31 18 22 23 125 31 32 37 29 30 36 31 32 37 32 32 33 33 32 33 29 29 30 29 28 35 33 30 35 20 19 26 250 43 44 47 40 39 40 43 44 47 44 46 46 45 47 49 44 46 46 44 44 50 46 45 50 44 44 50 500 50 51 54 51 52 54 47 48 51 57 55 54 56 56 53 50 48 47 52 52 53 56 55 56 42 42 43 1.000 2.000 4.000 8.000 58 58 44 34 56 57 42 33 56 59 41 31 56 56 45 34 56 56 43 33 55 53 43 33 46 52 38 25 44 51 36 24 44 53 35 22 55 55 55 53 52 50 50 50 50 55 53 55 55 53 52 48 46 48 53 53 53 53 52 51 50 50 50 54 52 55 54 52 52 50 48 51 45 44 44 44 43 41 39 38 38 44 44 45 43 43 42 36 36 37 36 36 36 36 35 33 29 29 29 33 35 35 34 34 33 23 25 25 GLOBAL 61 60 62 60 60 59 54 54 56 60 60 59 59 59 57 55 55 55 59 58 60 60 59 59 53 52 55 TD-500/150 ECOWATT B M INLET A B M OUTLET A B M RADIATED A TD-800/200 ECOWATT B M INLET A B M OUTLET A B M RADIATED A 63 26 26 26 34 29 31 18 18 18 27 26 36 48 40 36 27 26 36 125 36 34 37 36 34 34 24 22 25 35 33 47 47 39 43 22 20 34 250 53 50 53 56 51 55 51 48 51 51 49 63 51 49 61 41 39 53 500 56 55 58 61 60 65 37 36 39 55 54 64 61 62 68 36 35 45 1.000 2.000 4.000 8.000 58 64 58 50 57 61 55 48 59 61 56 48 62 62 57 50 61 59 55 48 62 59 56 49 45 55 43 35 44 52 40 33 46 52 41 33 66 65 66 65 65 67 54 53 54 66 63 63 67 65 65 56 53 53 61 59 59 62 59 60 48 46 46 51 49 51 50 48 51 33 31 33 GLOBAL 67 64 65 67 66 68 57 54 55 70 68 71 71 69 72 59 57 59
Dimensions (mm)
211 111.5
273
173,5
80 295
147 200
TD-160/100 ECOWATT
X
5. 5
TD-500/150 ECOWATT
233
124
C
94
.5
G A
D B
100 302
198 217
TD-800/200 ECOWATT
548
140
293
184
130
60
5 5.
Characteristic curves
Q = Air volume in, m3/hr and m3/s. Pe = Static pressure in mmWG and Pa. Dry air at 20C and 760 mmHg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985.
Pa Pe mmWG
Pa
Pe mmWG
Pa
Pe mmWG
Pa
Pe mmWG
Pa
Pe mmWG
549
TD ECOWATT
TD-MIXVENT
0 026082 603076
SELECTION EXAMPLE DATA: Airflow: 700 m3/h (Q) Input air temperature: +5 C Required output temperature: +27 C In those installations where MIXVENT HEATING system is required it is convenient to use filter boxes MFL to protect the electrical P = Q x 0,36 x T = 700 x 0,36 x 22 = 5544 W batteries from the debris.
BATTERY ELECTION Or: MBE-200/50T Or: MBE-250/60T Final election will depend of: Total pressure drop Desired sound level Available space
550
Dimensions (mm)
Room temperature sensor TG-R530 To place in the room to heat: NTC type with linear scale Operating temperature: 0 -30C IP-20 Suitable for controller type TTC-2000.
Duct temperature sensor TG-K330 Temperature sensor to place in the warm air supply ducting. NTC type with linear scale Operating temperature: 0 -30C IP-20 Suitable for controllers type PULSER and TTC-2000.
140
551
TD-MIXVENT
A usual application of MFL filtration boxes is to protect the electrical heater batteries from the dirt, in installations where MIXVENT HEATING system is used.
0 026182 603075
Dimensions (mm)
E F
D B
The MFL filtration boxes are supplied with a cover easily removable to replace the filter.
552
A C
MCA-250 to 2000 Model MCA/JCA MCA - 250 MCA - 350 MCA - 500/150 MCA - 500/160 MCA - 800 MCA - 1000 MCA - 2000 MCA - 4000 MCA - 6000 Type of TD - TDx2 - TDx3 - TWIN 160/100N - 250/100 350/125 500/150 500/160 800/200 - 800/200N 1000/250 - 1300/250 2000/315 4000/355 6000/400 Model MCA MCA - 250 MCA - 350 MCA - 500/150 MCA - 500/160 MCA - 800 MCA - 1000 MCA - 2000 MCA - 4000 MCA - 6000 A 107 107 121 121 131,5 164 205 265 307
MCA-4000/6000 B 111 136 163,5 173,5 214 264,5 330 374 419 C 31,5 31,5 35 35 35 42 50 55 65 D 94,5 119,5 147 157 197,5 248 312 354 399
MAR Rectangular Duct Adapters enable TD, TDx2 and TDx3 to be connected to rectangular ducting.
F A C
Model MAR
Type of TD-TDx2-TDx3
Model MAR MAR - 250 MAR - 350 MAR - 500/150 MAR - 500/160 MAR - 800 MAR - 1000 MAR - 2000
G 9 9 9 9 9 9 9
MAR - 250 160/100N - 250/100 MAR - 350 350/125 MAR - 500/150 500/150 MAR - 500/160 500/160 MAR - 800 800/200-800/200N MAR - 1000 1000/250-1300/250 MAR - 2000 2000/315
MRJ Grilles mounted at the inlet or outlet of the fan, to prevent the entry of any foreign objects that could damage the fan. To apply with TD, TD x 2, TD x 3 and TWIN models.
Model MRJ MRJ - 250 MRJ - 350 MRJ - 500/150 MRJ - 500/160 MRJ - 800 MRJ - 1000 MRJ - 2000 MRJ - 4000 MRJ - 6000
Type of TD - TDx2 - TDx3 - TWIN 160/100N - 250/100 350/125 500/150 500/160 800/200 - 800/200N 1000/250 - 1300/250 2000/315 4000/355 6000/400
553
TD-MIXVENT
TD-MIXVENT
KIT TWIN BASE This accessory consists of two rectangular duct couplings with standardized dimensions and two supports allowing mounting two TD or two TDx2 fans in parallel.
KIT TWIN BASE KIT TWIN BASE 250 KIT TWIN BASE 350 KIT TWIN BASE 500/150 KIT TWIN BASE 500/160 KIT TWIN BASE 800 KIT TWIN BASE 1000 KIT TWIN BASE 2000
Dimensions (mm) L 320 320 395 395 440 540 690 H 180 180 220 220 240 290 355
Nominal dim. of rectangular duct (mm) L 280 280 355 355 400 500 630 H 140 140 180 180 200 250 315
Due to the independent operation of TD models, backdraft shutters mounted at the outlet of TD fans are required in order to avoid the backdraft of air when the fan is disconnected.
"
Model SIL 125 SIL 160 SIL 200 SIL 250 SIL 315 SIL 355 SIL 400
Attenuation in dB 63 2 2 2 2 2 3,7 1,8 125 5 9 8 6 2,2 4,1 3,1 250 13 14 11 10 3,3 6,7 4 500 21 23 23 19 9 13,2 9,5 1000 37 25 25 25 21,2 14,3 13,7 2000 37 16 17 16 7,6 3,4 5,6 4000 31 11 9 7 4,1 8,1 0,4 8000 9 6 4 3 5,5 7 5,9
SIL sound attenuator mounted together with a TD-MIXVENT, a filter box MFL and a heat electrical battery MBE
554
RED Reducer
Electrical accessories
REGUL 2 2 Speed switch REB Single-phase electronic speed controller RMB Single-phase auto-transformer speed controller
555
TD-MIXVENT