Columbus, IN 47201
Displacement:
Bore:
Stroke:
Cylinders:
Fuel System:
Curve Number:
QSK38-M
M-6756
Engine Configuration
CPL Code:
Date:
D233041MX03
CPL 03327
16-Aug-11
CERTIFIED: This diesel engine complies with or is certified to the following agencies requirements:
IMO Tier II (Two) NOx requirements of International Maritime Organization (IMO), MARPOL 73/78 Annex VI, Regulation 13
EPA Tier 2 - Model year requirements of the EPA marine regulation (40CFR94)
EU Stage IIIa - EC Nonroad Mobile Machinery Directive (2004/26/EC)
1500
1100
1400
1000
1800
1300
1900
900
1200
800
1100
Power (kw)
900
600
800
Propeller Demand
500
700
Power (hp)
1000
Full Throttle
700
600
400
500
300
400
300
200
200
100
100
(60.5)
(51.4)
(44.4)
(37.3)
(30.9)
(25.1)
(20.2)
(15.7)
(11.8)
(8.7)
(6.4)
(4.5)
QSK38-M
Continuous Duty
895 [1200]
1800
-3/+5
4747 [3501]
5553 [4096]
1575 [228]
1837 [266]
2400
3164 [2334]
15:1
9.5 [1878]
2-11-10-3-6-7-12-1-4-9-8-5
5205 [11475]
5450 [12015]
8.5
5%
0%
16%
1900
550
10
1900
1995
(Idle).. ..........dBA @ 1m
(Rated) ............dBA @ 1m
(Idle).. ..........dBA @ 1m
(Rated) ............dBA @ 1m
(Idle).. ..........dBA @ 1m
(Rated) ............dBA @ 1m
(Idle).. ..........dBA @ 1m
(Rated) ............dBA @ 1m
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
Fuel System
Avg. Fuel Consumption - ISO 8178 E3 Standard Test Cycle ..................l/hr [gal/hr]
Fuel Consumption at Rated Speed ............l/hr [gal/hr]
Approximate Fuel Flow to Pump ......................l/hr [gal/hr]
Maximum Allowable Fuel Supply to Pump Temperature ............ ...............C [F]
Approximate Fuel Flow Return to Tank ...................l/hr [gal/hr]
Approximate Fuel Return to Tank Temperature ................C [F]
Maximum Heat Rejection to Drain Fuel ....................kW [Btu/min]
165.5
229.1
548.9
60.0
319.8
44.5
0.7
TBD= To Be Determined
M-6756
D23-MX-1
CPL 03327
16-Aug-11
[43.7]
[60.5]
[145.0]
[140]
[84.5]
[112]
[41]
Unless otherwise specified, all data is at rated power conditions and can vary 5%.
No rear loads can be applied when the FPTO is fully loaded. Max PTO torque is contingent on torsional analysis results for the specific drive
system. Consult Installation Direction Booklet for Limitations.
Heat rejection to coolant values are based on 50% water/50% ethylene glycol mix and do NOT include fouling factors. If sourcing your own cooler,
a service fouling factor should be applied according to the cooler manufacturer's recommendation.
Consult option notes for flow specifications of optional Cummins seawater pumps, if applicable.
5 May not be at rated load and speed. Maximum heat rejection may occur at other than rated conditions.
4
http://marine.cummins.com/
M-6756
D23-MX-1
CPL 03327
16-Aug-11
Air System
Intake Manifold Pressure ..........................kPa [in Hg]
Intake Air Flow .............................l/sec [cfm]
Heat Rejection to Ambient .........................kW [Btu/min]
203 [60]
1504 [3187]
36 [2037]
Exhaust System
Exhaust Gas Flow ..........................................l/sec [cfm]
Exhaust Gas Temperature (Turbine Out) ....................................................C [F]
Exhaust Gas Temperature (Manifold) .......................................C [F]
2949 [6,249]
332 [630]
491 [915]
6.37
0.20
1.15
0.17
Cooling System
Sea Water Pump Specifications ............................................MAB 0.08.17-07/16/2001
Pressure Cap Rating (With Heat Exchanger Option) ....................................................kPa [psi]
103 [15]
[4.75]
[0.15]
[0.86]
[0.13]
TBD= To Be Determined
1128
82
95
520
[298]
[180]
[202]
[29586]
598
46
57
223
49
[158]
[115]
[135]
[12675]
[120]
Unless otherwise specified, all data is at rated power conditions and can vary 5%.
No rear loads can be applied when the FPTO is fully loaded. Max PTO torque is contingent on torsional analysis results for the specific drive
system. Consult Installation Direction Booklet for Limitations.
Heat rejection to coolant values are based on 50% water/50% ethylene glycol mix and do NOT include fouling factors. If sourcing your own cooler,
4
5
a service fouling factor should be applied according to the cooler manufacturer's recommendation.
Consult option notes for flow specifications of optional Cummins seawater pumps, if applicable.
May not be at rated load and speed. Maximum heat rejection may occur at other than rated conditions.
http://marine.cummins.com/