Você está na página 1de 2

H U N T E R

P A N E L S

E N E R G Y

S M A R T

P O L Y I S O

H-Shield

Flat Polyisocyanurate Insulation H-Shield THERMAL VALUES



Thickness LTTR Flute (Inches) (mm) R Value* Spanability

H-Shield

1.00 1.50 1.60 1.70 2.00 2.50 2.70 3.00 3.30 3.50 3.60 4.00 4.50

25 38 41 43 51 64 69 76 84 89 91 102 114

6.00 9.00 9.60 10.30 12.10 15.30 16.60 18.50 20.40 21.70 22.40 25.00 28.10

2 4 4 4 4 4 4 4 4 4 4 4 4

5/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8"

Product Description

*Long Term Thermal Resistance Values are based on ASTM C1289 and CAN/ULC S770 which provides for a 15-year time weighted average.

H-Shield is a rigid roof insulation panel composed of a closed cell polyisocyanurate foam core manufactured on-line to fiber reinforced facers on each side.
Features and Benefits Manufactured with NexGen Chemistry: Contains no CFCs, HCFCs, is Zero ODP, EPA Compliant, and has virtually no GWP Approved for direct application to steel decks Approved under all major roof covering systems BUR, Modified and Single-Ply Panel Characteristics Available in two grades of compressive strengths per ASTM C1289 Type II, Class 1 Grade 2 (20 psi) or Grade 3 (25 psi) Available in 4'x4' (1220mm x 1220mm) and 4'x8' (1220mm x 2440mm) panels in thickness of 1" (25mm) to 4.5" (114mm) Applications Constructions requiring FM Class 1 and UL Class A ratings Single-Ply Roof Systems (Ballasted, Mechanically Attached, Fully Adhered) Standing Seam Metal Roof Systems Modified Bitumen Systems Built-Up Roofing: Asphalt and Coal Tar

Codes and Compliances ASTM C 1289 Type II, Class 1 Grade 2 (20 psi) or Grade 3 (25 psi) International Building Code (IBC) Chapter 26 State of Florida Product Approval Number FL 5968 Miami Dade County, FL NOA NO: 09-0915.15 Exp. 1.14.2015 Underwriters Laboratories Inc Classifications UL 1256 Insulated Metal Deck Construction Assemblies No. 120, 123, 292 UL 790 UL 263 Hourly Rated P Series Roof Assemblies UL Classified for use in Canada Refer to UL Directory of Products Certified for Canada for more details Factory Mutual Approvals FM 4450, FM 4470 Approved for Class 1 insulated steel deck constructions for 1-60 to 1-270. Refer to FM Approvals RoofNav for details on specific systems LEED Potential credits for Polyiso use Energy and Atmosphere Optimize Energy Performance Measurement & Verification Materials & Resources Material Reuse Construction Waste Management Recycled Content Local and Regional Materials Innovation and Design Sustainable Sites Heat Island Effect: Roof 8 8 8 . 7 4 6 . 1 1 1 4

w w w . hunterpanels . c om

H U N T E R

P A N E L S

E N E R G Y

S M A R T

P O L Y I S O

PROPERTY

TYPICAL PHYSICAL PROPERTY DATA CHART polyiso foam core only TEST METHOD
ASTM D 1621 ASTM C 1289

WARNINGS AND LIMITATIONS Insulation must be protected from open flame and kept dry at all times. Install only as much insulation as can be covered the same day by completed roof covering material. Hunter Panels will not be responsible for specific building and roof design by others, for deficiencies in construction or workmanship, for dangerous conditions on the job site or for improper storage and handling. Technical specifications shown in this literature are intended to be used as general guidelines only and are subject to change without notice. For more information refer to the Storage and Handling Technical Bulletin at www.hpanels.com, or refer to PIMA Technical Bulletin No. 109: Storage & Handling Recommendations for Polyiso Roof Insulation at www.polyiso.org.

VALUE
20 psi* minimum (138kPa, Grade 2) 2% linear change (7 days) < 1 perm (57.5ng/(Pasm2)) < 1% volume -100 to 250 F (-73C to 122C)

Compressive Strength

Dimensional ASTM D 2126 Stability oisture Vapor M ASTM E 96 Transmission Water Absorption ASTM C 209

Service Temperature

*Also available in 25 PSI Minimum, Grade 3

Single-Ply Systems
Ballasted Single-Ply Systems

INSTALLATION

Each H-Shield panel is loosely laid on the roof deck. Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturers specifications.
Mechanically Attached Single-Ply Systems

Each H-Shield panel must be secured to the roof deck with fasteners and plates (appropriate to the deck type). Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturers specifications.
Fully Adhered Single-Ply

Each H-Shield panel must be secured to the roof deck with fasteners and plates (appropriate to the deck type). Maximum 4x4(1220mm x 1220mm) panels of H-Shield may be adhered to a prepared concrete deck or subsequent layers of insulation with a full mopping of hot steep asphalt, insulation adhesive or cold applied mastic. Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturers specifications. R-30.6, two layers of 2.5" H-Shield with Single-Ply membrane Built Up, Coal Tar And Modified Bitumen Systems Each H-Shield panel must be secured to the roof deck with fasteners and plates (appropriate to the deck type). Maximum 4x4 (1220mm x 1220mm) panels of H-Shield may be adhered to a prepared concrete deck or subsequent layers of insulation with a full mopping of hot steep asphalt, insulation adhesive or cold applied mastic. Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturers specifications.

Energy Smart Polyiso hunterpanels.com