Grundfos Basic
50 Hz
Contents
JPBasic
Performance range General data Applications Constructional features Material specification Technical data Curve conditions Page Page Page Page Page Page Page 3 4 4 4 5 5 5
CHBasic PS
General data Applications Constructional features Material specification Technical data Curve conditions Page Page Page Page Page Page 26 26 26 26 27 27
JPBasic PT
General data Applications Constructional features Material specification Technical data Page Page Page Page Page 10 10 10 10 11
CHBasic PC
General data Applications Operation Constructional features Material specification Technical data Curve conditions Page Page Page Page Page Page Page 28 28 28 28 29 30 30
JPBasic PS
General data Page 12
NSBasic
Performance range General data NSBasic single impeller pumps Applications Constructional features Material specification Technical data NSBasic twin impeller pumps Applications Constructional features Material specification Technical data Page Page Page Page Page Page Page Page Page Page Page Page 31 32 32 32 32 32 33 35 35 35 35 36
JPBasic PC
General data Applications Operation Technical data Page Page Page Page 13 13 13 15
JDBasic
General data Applications Constructional features Material specification Technical data Instructions for conversion Page Page Page Page Page Page 16 16 16 16 17 18
KPBasic
Performance range General data Applications Constructional features Technical data Curve conditions Page Page Page Page Page Page 39 40 40 40 41 41
CHBasic
Performance range General data Applications Constructional features Material specification Technical data Curve conditions Page Page Page Page Page Page Page 19 20 20 20 20 21 21
PFBasic
Performance range General data Applications Constructional features Material specification Technical data Page Page Page Page Page Page 44 45 45 45 45 46
CHBasic PT
General data Applications Constructional features Material specification Technical data Curve conditions Page Page Page Page Page Page 24 24 24 24 25 25
PFPBasic
General data Applications Constructional features Materials Technical data Page Page Page Page Page 47 47 47 47 48
JPBasic
JPBasic
Performance range
p [kPa] H [m]
65 600
JPBasic
50 Hz
60
55 500
50
45 400
40 5 35 7
300
30 4
10 9
25 200
20
15 2 100 10
0
TM02 8936 1804
10
Q [m/h]
3.0
0.0
0.5
1.0
1.5
2.0
2.5
Q [l/s]
JPBasic
General data
JPBasic 9, JPBasic 10
Gr7903
Applications
Self-priming centrifugal pump with excellent suction capacity even when there are air bubbles and small sandy impurities in the water. Used especially for supplying water to domestic systems. Ideal for use in small-scale agriculture and gardening, limited industrial services and wherever selfpriming operation is necessary.
JPBasic 5, JPBasic 7
Constructional features
Pump Cast iron pump body and motor support in cast iron treated against corrosion also on the inner surface. Technopolymer impeller, diffuser venturi tube and sand tube. Stainless steel pressure disc. Carbon/ceramic mechanical seal mounted on stainless steel rotor shaft extension. Motor Asynchronous motor cooled with external fan. Rotor mounted on greased sealed-for-life ball bearings, selected to ensure silent running and a long life. Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phase version. The user is responsible for protection in the three-phase version. Motor protection: IP 44 Terminal box protection: IP 55 Insulation class: F Standard voltage: 1 x 220-240 V, 50 Hz 3 x 220-240/380-415 V, 50 Hz.
Gr7917
Gr7921
JPBasic
Technical data
Material specification
Pos. 1 3 4 6 7 8 16 28 Description Pump body Support Impeller Diffuser Shaft Venturi tube and nozzle Mechanical seal O-Ring gasket Material Cast iron EN-GJL-200 Cast iron EN-GJL-200 Noryl GFN 2 Noryl GFN 2 AISI 303 stainless steel X 10 Cr NiS 18 9 * Noryl GFN 2
TM02 8459 0204
6 28
Carbon/Ceramic NBR
Technical data
Operating range: Liquid quality requirements: Liquid temperature range: From 0.6 to 10.5 m3/h with head up to 63 metres Clean, free from solids or abrasive substances, non aggressive From 0C to +35C for domestic use (Safety regulations EN 60335-2-41) From 0C to +40C for other uses.
Maximum ambient temperature: +40C Maximum suction depth: Maximum operating pressure: Installation: Special executions on request: 8 metres JPBasic 2, JPBasic 3, JPBasic 4: JPBasic 5, JPBasic 7, JPBasic 9, JPBasic 10: Fixed in a horizontal position Other voltages and/or frequencies. 6 bar (600 kPa) 7.5 bar (750 kPa)
Curve conditions
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A.
Technical data
JPBasic
JPBasic 2
A A1 C DNA DNM
0 0
2 2
4 4
6 6
8 8
10
12 10
H [m] 40 35 30 25 20 15 10 5 0
H3
I G B
8 7 6
60
5 4 3 2
40 20 0
0.4
0.6
P2
[kW]
P2
[hp]
In
[A]
JPBasic 2
3.12
Dimensions [mm] A 395 A1 390 B 178 C 108 E 192 F 14 G 111 H 200 H3 144 I 9 DNA Rp 1 DNM Rp 1
JPBasic 3
A A1 C DNA DNM
0 0
2 2
4 4
6 6
10 8
12 10
P [kPa] 400
H
H [m] 45 40 35 30 25 20
H3
320
240 160 80 0
I G B
7 6 5 4 3 2
60 40 20 0
Electrical data Pump type Voltage [V] 1 x 220-240 3 x 220-240/380-415 P1 Max. [kW] 0.85 0.86 P2
[kW]
P2
[hp]
In
[A]
JPBasic 3
0.6 0.6
0.8
3.8
0.8 2.8/1.6
Dimensions [mm] A 395 A1 390 B 178 C 108 E 192 F 14 G 111 H 200 H3 144 I 9 DNA Rp 1 DNM Rp 1
Weight [kg] 11
2.8 0.8
Q [m/h] Q [l/s]
0.0 0.0
0.4
0.8 0.2
1.2
1.6
2.0
2.4
Q [m/h] Q [l/s]
Technical data
JPBasic
JPBasic 4
A A1 C DNA DNM
0 0
2 2
4 4
6 6
10 8
12 10
P [kPa]
H [m] 50 45 40 35 30 25
H3
400 300
I G B
200 100 0
80
7 6 5 4 3 2
60 40 20 0
[kW] [hp]
JPBasic 4
1.13 0.75
5.1 3.3/1.9
Dimensions [mm] A 414 A1 409 B 178 C 108 E 197 F 14 G 111 H 213 H3 144 I 9 DNA Rp 1 DNM Rp 1
JPBasic 9
A C DNA
P [kPa] 400 H [m] 40 35 300 30 25 120 100 80 60 40
8 7 6 5 4
0 0
4 4
8 8
12
16 20 24 28 32 36 40 44 48 12 16 20 24 28 32 36 40
H1
I G B
200
20 15
100
10 5
3 2 1
20 0
Electrical data Pump type Voltage [V] 1 x 220-240 JPBasic 9 3 x 220-240/ 380-415 P1
Max. [kW]
P2
[kW]
P2
[hp]
In
[A]
Capacitor [F] 31.5 [Vc] 450 0 20 40 60 80 100 120 140 160 180Q [l/min]
2 2
1.5 1.5
2 2
9 6.8/3.9
Dimensions [mm] A 521 B 214 C 151 E 282 F 20 G 160 I 11 H 227 H1 175 DNA Rp 1 DNM Rp 1
Weight [kg] 27
2.8 0.8
Q [m/h] Q [l/s]
Technical data
JPBasic
JPBasic 10
0
A A1 C
4 4
8 8
12
16 20 24 28 32 36 40 44 48 12 16 20 24 28 32 36 40
DNA
DNM
P [kPa]
H [m] 50 45 40 35 30 25 20 15 10 5 0
H3
400 300
I G B
200 100 0
60
7
40
6 5 4 3 2 1
20 0
Electrical data Pump type Voltage [V] 1 x 220-240 JPBasic 10 3 x 220-240/ 380-415 P1
Max. [kW]
0.4
P2
[kW]
P2
[hp]
In
[A]
Capacitor [F] 40 [Vc] 450 0 20 40 60 80 100 120 140 160 180Q [l/min]
2.7 2.7
2.2 2.2
3 3
12 8.5/4.9
Dimensions [mm] A 595 B 214 C 151 E 282 F 20 G 160 I 11 H 235 H1 175 DNA Rp 1 DNM Rp 1
JPBasic 5
0
Z C A B DNM
2 2
4 4
6 6
10 8
12 10
14 12
16 14
18
20 16
P [kPa] 600
H [m] 60 50 40 30 20 10 0
V H H
DNA
500
H2
DNE
400
H1
H1
X A E
I G
6 7 5 4 3 2 1
80 40 0
Electrical data Pump type Voltage [V] 1 x 220-240 JPBasic 5 3 x 220-240/ 380-415 P1
Max. [kW]
P2 1.1 1.1
P2 1.5 1.5
In
[A]
[kW] [hp]
1.6 1.6
7.2 5.2/3.0
Dimensions [mm] A 558 B 210 C 221 E 350 F 20 G 145 I 11 H 255 H1 158 DNA Rp 1 DNM Rp 1
Weight [kg] 31
0.0 0.0
0 0.0
3 0.8
4 5 6 1.2 1.6
7 8 9 2.0 2.4
Technical data
JPBasic
JPBasic 7
0
Z C A B DNM
4 4
8 8
12 12
16
20 16
24 20
28 24
32 28
P [kPa] 600
H [m] 60 50 40 30 20 10
V H H
DNA
500 400
H2
DNE
H1
H1
8 7
120
6 5 4 3 2
X A E
I G
80 40
1
Electrical data Pump type Voltage [V] 1 x 220-240 JPBasic 7 3 x 220-240/ 380-415 P1
Max. [kW]
P2
[kW]
P2
[hp]
In
[A]
2.2 2.2
1.85 1.85
2.5 2.5
10 6.9/4.0
Dimensions [mm] A 632 B 210 C 221 E 350 F 20 G 145 I 11 H 255 H1 158 DNA Rp 1 DNM Rp 1
Weight [kg] 35
JPBasic PT
General data
JPBasic PT
Tank Horizontal type, capacity 19 litres, with butyl diaphragm, complete with feet on the bottom and brackets for fixing the pump on top.
8 1 6 28 3
16
Applications
Automatic water lifting and pressure boosting sets, particularly suitable for domestic use, small installations for civil, industrial and agricultural use, washing systems and hobbies. The characteristics of the JPBasic-pumps are that they are self-priming electric pumps which can operate even when there is air, gas and small quantities of sand in the water. The set is composed of a diaphragm tank with capacity 19 litres, pressure switch for automatic operation, pressure gauge, JPBasic electric pump complete with power cable and plug, kit for coupling the pump and the tank, all assembled and ready for installation. Note: Vertical 8 litres or 18 litres tanks are used in some markets.
Material specification
Pos. 1 3 4 6 7 8 16 28 Support Impeller Diffuser Shaft Venturi tupe and nozzle Mechanical seal O-Ring gasket Description Pump body Material Cast iron (EN-GJL-200) Cast iron (EN-GJL-200) Noryl GFN 2 Noryl GFN 2 Stainless steel AISI 416 X12 CrS 13 Noryl GFN 2 Carbon/Ceramic NBR
Constructional features
Pump Cast iron pump body and motor support. Technopolymer impeller, diffuser, Venturi tube and sand guard. Stainless steel pressure discs. Carbon/ceramic mechanical seal. Motor Induction motor, closed and cooled with external ventilation. Rotor mounted on oversized greased sealed-forlife ball bearings, to ensure silent running and a long life. Built-in thermal and current overload protection and a capacitor permanently in circuit. Manufactured according to standard EN 60335-2-41. Motor protection: Insulation class: Standard voltage: IP 44 F 1 x 220-240 V, 50 Hz.
10
JPBasic PT
Technical data
Technical data
Operating range: Liquid quality requirements: Liquid temperature range: Up to 3.6 m3/h with head up to 51 metres. Clean, free from solids or abrasive substances, non viscous, non aggressive, non crystallized, chemically neutral, close to the characteristics of water. From 0C to +35C for domestic use (Safety regulations EN 60335-2-41) From 0C to +40C for other uses.
Maximum ambient temperature: +40C Maximum operating pressure: Installation: 6 bar (600 kPa) Fixed in a horizontal position.
JPBasic PT
A1 D
0 0 2 2 4 4 6 6 8 10 8 12 10 14 Q [US GPM] Q [IMP GPM] H [ft] 160 140 120
JPBasic 4
H1
P [kPa]
H [m] 50 45 40 35 30 25 20 15 10 5 0
400 300
JPBasic 2 JPBasic 3
100 80 60 40 20 0
200 100 0
B L
Electrical data Pump type JPBasic 2 PT JPBasic 3 PT JPBasic 4 PT Voltage [V] 1 x 220-240 1 x 220-240 1 x 220-240 P1 Max. [kW] 0.72 0.85 1.13 P1
[hp]
In
[A]
10
20
30
40
50 Q [l/min]
Dimensions [mm] A 550 550 550 A1 390 390 409 B 270 270 270 D 282 282 282 H 290 290 290 H1 232 232 232 L 332 332 332
DNA Rp 1 Rp 1 Rp 1
DNM Rp 1 Rp 1 Rp 1
Packing dimensions [mm] L/A 576 576 576 L/B 366 366 366 L/H 554 554 554
0.0 0.0
0.4
0.8 0.2
1.2
1.6 0.4
2.8 0.8
Q [m/h] Q [l/s]
11
JPBasic PS
General data
JPBasic PS
Auto pressure units Single-phase version: Self-priming centrifugal pump equipped with pressure gauge, pressure switch (PS), power supply cable with plug and three-way brass connector for connecting to a tank.
JPBasic-PS
Voltage [V]
P1
Max. [kW]
Electrical data P2 P2 In
Max. [kW] [hp] [A]
Capacitor [F] 12.5 12.5 16 31.5 [Vc] 450 450 450 450
1 x 220-240 0.72 0.44 1 x 220-240 0.85 0.6 1 x 220-240 1.13 0.75 1 x 220-240 1.6 1.1
Gr7908
Pump type JPBasic 2 PS JPBasic 3 PS JPBasic 4 PS JPBasic 5 PS A 395 395 414 563 A1 390 390 390 556 B 282 282 282 217 C 108 108 108 160 D 196 196 196 109
Dimensions [mm] E 192 192 192 329 F 14 14 14 15 G 111 111 111 145 I 11 H 232 232 232 312 H1 199 199 199 279 H2 200 200 221 H3 144 144 144 159 I 9 9 9 -
DNA Rp 1 Rp 1 Rp 1 Rp 1
DNM Rp 1 Rp 1 Rp 1 Rp 1
Packing dimensions [mm] L/A L/B L/H 486 366 232 486 366 232 486 366 232 600 236 267
12
JPBasic PC
General data
JPBasic PC
Self-priming centrifugal pump equipped with presscontrol (PC) and power supply cable.
Applications
Automatic water lifting sets, particulary suitable for domestic use, small installations for civil, industrial and agricultural use, washing systems and hobbies. These are characterised by the use of JPBasic PC selfpriming centrifugal pumps which can operate even when there is air, gas and small quantities of sand in the water. They are indispensable for use in artesian wells and whereever suction difficulties arise.
Operation
The pump is equipped with a Presscontrol (PC) which controls, manages and commands it, regulating its operation, limiting the number of starts and guaranteeing maximum pressure stability inside the hydraulic circuit in which it is installed. The automatic devices is the result of a series of studies conducted to optimise the efficiency of the system while preserving the structural features and sturdiness of existent devices. Automatic sets differ from the traditional systems equipped with a pressure switch based on pump starting and stopping as they avoid sudden variations and drops in pressure. They are basically equipped with a double control device, as built-in electrical circuit gathers the data regarding pressure and water flow in the system and processes them to allow the pump to operate under optimum performance conditions. The automatic device is supplied pre-installed on the pump, requires no type of regulation and considerably reduces overall dimensions by totally eliminating the bulky tanks used traditional installations.
Gr7907
13
JPBasic PC
General data
All the pumps are supplied with 0.75 metres of power cable type H05 RN-F with plug.
14
JPBasic PC
Technical data
Technical data
Operating range: Liquid quality requirements: Liquid temperature range: From 0.3 to 3.6 m3/h with head up to 51 metres Clean, free from solids or abrasive substances, non aggressive From 0C to +35C for domestic use (Safety regulations EN 60335-2-41) From 0C to +40C for other uses.
Maximum ambient temperature: +40C Maximum operating pressure: Installation: 6 bar (600 kPa) Fixed in a horizontal position.
JPBasic PC
C DNM
0 0
2 2
4 4
6 6
10 8
12 10
P [kPa]
H [m] 50 45 40 35 30 25 20 15 10 5 0
DNA
400 300
100 80 60 40 20 0
H3
200 100 0
F E A
I G B
Electrical data Pump type JPBasic 2 PC JPBasic 3 PC JPBasic 4 PC Voltage [V] 1 x 220-240 1 x 220-240 1 x 220-240 P1
Max. [kW]
10
20
30
40
50 Q [l/min]
P2
[kW]
P2
[hp]
In
[A]
Pump type A JPBasic 2 PC JPBasic 3 PC JPBasic 4 PC 395 395 414 B 212 212 212 C 108 108 108
Dimensions [mm] E 192 192 197 F 14 14 14 G 111 111 111 I 9 9 9 H 375.5 375.5 375.5 H3 144 144 144
DNA Rp 1 Rp 1 Rp 1
DNM Rp 1 Rp 1 Rp 1
Packing dimensions [mm] L/A 524 524 524 L/B 248 248 248 L/H 309 309 309
Weight [kg] 14 16 16
0.0 0.0
0.4
0.8 0.2
1.2
1.6 0.4
2.8 0.8
Q [m/h] Q [l/s]
15
JDBasic
General data
JDBasic 2, JDBasic 4
JDBasic 5, JDBasic 7
Gr7899General data
Applications
Self-priming centrifugal pump for suction up to 27 metres, reached by means of an ejector to be inserted in wells with a diameter of 4" or over. For use in supplying water to farmhouses and in small-scale agriculture.
Motor Asynchronous motor, closed and cooled with external ventilation. Rotor mounted on greased sealed-for-life ball bearings, selected to ensure silent running and a long life. Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phase version. For the protection of the three-phase motor it is advisable to use a suitable overload protection complying with the regulations in force. Manufactured according to standard EN 60335-2-41. Motor protection: Terminal box protection: Insulation class: Standard voltage: IP 44 IP 55 F 1 x 220-240 V, 50 Hz 3 x 220-240/380-415 V, 50 Hz.
Constructional features
Pump Cast iron pump body and motor support treated against corrosion also on the inner surface. Technopolymer impeller, diffuser and Venturi tupe and brass nozzle. Stainless steel pressure disc. Carbon/ceramic mechanical seal mounted on stainless steel rotor shaft extension. Ejector: Cast iron body with anti-corrosive treatment also on the inner surface. Technopolymer Venturi tube and brass nozzle. The ejector is available in 3 models (E20 - E25 - E30) to be chosen according to performance requirements. (see tables on pages 17 and 18).
Material specification
Pos. 1 2 3 4 6 Description Pump body Ejector body Support Impeller Diffuser Material Cast iron EN-GJL-200 Cast iron EN-GJL-200 Cast iron EN-GJL-200 Noryl GFN 2 Noryl GFN 2 (JDBasic 2-4) Stainless steel AISI 416 X 12 Cr S 13
9 16 4 7
TM02 8456 0204
1 6 28
(JDBasic 5-7) AISI 303 X10 Cr NiS 18 9 8 9 16 28 Venturi Nozzle Mechanical seal O-ring gasket Noryl GFN 2 Brass Carbon/Ceramic NBR
16
JDBasic
Technical data
Technical data
Operating range: Liquid quality requirements: Liquid temperature range: Up to 4.3 m3/h Clean, free from solids or abrasive substances, non aggressive From 0C to +35C for domestic use
Maximum ambient temperature: + 40C Maximum operating pressure: Installation: Special executions on request: JDBasic 2, JDBasic 4: 6 bar (600 kPa) JDBasic 5, JDBasic 7: 8 bar (800 kPa) Fixed in a horizontal position Other voltages and/or frequencies.
JDBasic 2, JDBasic 4
Hydraulic data (n 2850 min -1) Delivery pressure in bar
Z A
1.5 1813 1426 900 1753 1345 1166 2386 1930 1459 / / / /
2.0 1080 720 326 1286 965 761 1756 1190 773 1240 1028 785 635
2.5 446 225 / 812 608 452 1097 536 252 872 701 527 374
4.0 / / / 46 0 / / / / 156 96 15 /
H1
G B
JDBasic 2
H2
Pump type
H1 H2
DNA G1 G1
DNM G1 G1
DNE G1 G1
x G1 G1
y G1 G1
z G1 G1
Vol L/A L/B L/H [m3] [mm] [mm] [mm] 452 492 218 224 257 277
JDBasic 2 365 180 90 202 140 9,5 225 47 92 JDBasic 4 385 180 90 202 140 9,5 225 47 92
Electrical data Pump type Voltage [V] 1 x 220-240 JDBasic 2 3 x 220-240/ 380-415 P1
Max. [kW]
Electrical data In
[A]
P2
[kW]
P2
[hp]
Pump type
P1
Max. [kW]
P2
[kW]
P2
[hp]
In
[A]
0.69 0.66
0.44 0.44
0.6 0.6
3.2 2.6/1.5
0.79 0.64
0.75 0.75
1 1
3.8 2.6/1.5
JDBasic 4
3 x 220-240/ 380-415
Weight [kg]
Dimensions [mm]
Ejector
Packing dimensions
17
JDBasic
Technical data
JDBasic 5, JDBasic 7
Hydraulic data (n 2850 min -1)
A C B DNM
Delivery pressure [bar] 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 Capaticy table [l/h] / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
3412 2769 2090 1363 586 3065 2400 1719 952 143 2643 2000 1257 495 2289 1593 826 0 / /
E 20 JDBasic 5
12 15 18 15
2745 2244 1761 1257 814 435 77 2465 1969 1477 997 584 218 / 2206 1712 1224 779 388 45 /
I E G
E 25
18 21 21
1797 1615 1368 1106 861 658 472 312 163 25 / 1652 1484 1217 962 740 547 378 220 67 1520 1333 1069 841 636 448 287 139 / / / / / / / / / / / / 3431 2751 2033 1236 448 / 3043 2324 1554 763 2665 1936 1145 344 2244 1478 675 / 0 / / / / / / / / / / / / / / / /
E 30
Z C A
24 27 9 12 15 18 15
E 20
JDBasic 7
V H
2840 2324 1806 1296 849 463 138 / 2535 2038 1523 1049 640286 / 2267 1757 1257 817 424 91 / 1970 1458 989 583 226 / /
E 25
18 21 24 21
H1
X E
1812 1671 1419 1163 919 716 531 377 226 91 1668 1549 1278 1023 791 619 445 297 156 13 1541 1395 1145 906 700 521 351 206 62 /
E 30
24 27
H1 H2
DNA G1 G1
DNM DNE G1 G1 G1 G1
388 210 50 197 145 11 255 53 108 462 210 50 197 145 11 255 53 108
G1 G1 G1 G1 G1 G1
Electrical data Pump type JDBasic 5 JDBasic 7 Voltage [V] 1 x 220-240 1 x 220-240 P1
Max. [kW]
Electrical data In
[A]
P2
[kW]
P2
[hp]
Pump type
Voltage [V]
P2
[kW]
P2
[hp]
In
[A]
1.56 2.1
1.1 1.85
1.5 2.5
7 8.3
1.1 1.85
1.5 2.5
4.7/2.7 5.6/3.2
18
Weight [kg] 31 35
Dimensions [mm]
Ejector
CHBasic
CHBasic
Performance range
p
[kPa]
600
H [m]
60
CHBasic
50 Hz
3
55
500
50
4
45
400
40
35
300
30
25
200
20
15
100
10
0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5
Q [m/h]
TM02 8933 1804
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
Q [l/s]
19
CHBasic
General data
Applications
Multistage horizontal centrifugal pump, featuring extremely silent running suitable for domestic use for water supply and pressurisation, irrigation of gardens and vegetable gardens, and moving water in general.
Gr7896
16 28
Material specification
Pos. 1 3 4 6 7 16 28 Description Pump body Support Impeller Diffuser Shaft Mechanical seal O-ring gasket Material Cast iron EN-GJL-200 Cast iron EN-GJL-200 Noryl GFN 2 Noryl GFN 2 Stainless steel AISI 303 X10 CrNiS 18 9 Carbon/Ceramic NBR
Constructional features
Pump Pump body in cast iron. Motor support in die-cast aluminium, seal holder in stainless steel. Mechanical seal in carbon/ceramic. Shaft in stainless steel. Rotors, diffuser bodies and diffusers in technopolymer. Adjustment rings in stainless steel. Motor Continuous service asynchronous motor (2 poles) cooled by external fan. Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phase version. The user is responsible for protection in the three-phase version. Motor protection: IP 44 Terminal box protection: IP 55 Insulation class: F Standard voltage: 1 x 220-240 V, 50 Hz 3 x 220-240/380-415 V, 50 Hz.
20
CHBasic
Technical data
Technical data
Operating range: Liquid quality requirements: Liquid temperature range: From 0.6 to 10.5 m3/h with head up to 63 metres Clean, free from solids or abrasive substances, non aggressive, chemically neutral and close to the characteristics of water. From 0C to +35C for domestic use (Safety regulations EN 60335-2-41) From 0C to +40C for other uses.
Maximum ambient temperature: +40C Maximum suction depth: Maximum operating pressure: Installation: Special executions on request: 8 metres (800 kPa) CHBasic 2, CHBasic 3, CHBasic 4: Fixed in a horizontal position Other voltages and/or frequencies. 6 bar (600 kPa)
Curve conditions
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A.
21
CHBasic
Technical data
CHBasic 2
0 2 2 4 4 6 6 8 10 8 12 10 14 12 16 14 18 Q [US GPM] 16 Q [IMP GPM] H [ft] 160 140 120 100 80 60 40 20 0
A C DNM
P [kPa] H [m] 50 45 40 35 300 30 25 200 100 0 20 15 10 5 0 0.0 0.0 0.5 1.0 0.2 1.5 0.4 2.0 2.5 3.0 0.6 0.8 3.5 4.0 Q [m/h] 1.0 1.2 Q [l/s] 0
H1 DNA
H2
400
G B
Electrical data Pump type Voltage [V] 1x220-240 3x220-240/380-415 P1 Max. [kW] 0.7 P2
[kW]
P2
[hp]
In
[A]
CHBasic 2
3.2
Dimensions [mm] A 406 B 175 C 122 E 207 F 13.5 G 111 I 9 H 200 H1 179 H2 143.5 DNA Rp 1 DNM Rp 1
CHBasic 3
0 2 2 4 4 6 6 8 10 8 12 10 14 16 18 20 22 24 12 14 16 18 20 Q [US GPM] Q [IMP GPM] H [ft] 160 140 120 100 80 60 40 20 0
A C DNM
P [kPa] 500 H 0 [m] 55 50 45 400 300 200 100 0 40 35 30 25 20 15 10 5 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5Q [m/h] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 Q [l/s]
H1 DNA
H2
G B
Electrical data Pump type Voltage [V] 1x220-240 3x220-240/380-415 P1 Max. [kW] 1.2 1.2 P2
[kW]
P2
[hp]
In
[A]
CHBasic 3
0.75 0.75
1 1
5.3 3.8/2.2
Dimensions [mm] A 425 B 175 C 122 E 207 F 13.5 G 111 I 9 H 213 H1 179 H2 143.5 DNA Rp 1 DNM Rp 1
22
CHBasic
Technical data
CHBasic 4
0 4 4 8 8 12 12 16 20 16 24 20 28 24 32 28 Q [US GPM] Q [IMP GPM] H [ft] 160 140 120 100 80 60 40 20 0 0.4 1.2
A C DNM
P [kPa] H [m] 50 45 40 35 300 30 25 200 100 0 20 15 10 5 0 0 0.0 1 2 3 0.8 4 5 6 1.6 7 2.0 Q [m/h] Q [l/s] 0
H1 DNA
H2
400
G B
Electrical data Pump type Voltage [V] 1x220-240 3x220-240/380-415 P1 Max. [kW] 1.2 1.2 P2 0.8 0.8 P2 1.1 In
[A]
[kW] [hp]
CHBasic 4
5.3
1.1 3.8/2.2
13.5
23
CHBasic PT
General data
CHBasic PT
6 3
16 28
Applications
Multistage horizontal centrifugal pump, featuring extremely silent running suitable for domestic use for water supply and pressurisation, irrigation of gardens and vegetable gardens, and moving water in general. The set is composed of a diaphragm tank with capacity 19 litres, pressure switch for automatic operation, pressure gauge, JPBasic electric pump complete with power cable and plug, kit for coupling the pump and the tank, all assembled and ready for installation. Note: Vertical 8 litres or 18 litres tanks are used in some markets.
Material specification
Pos. 1 3 4 6 7 16 28 Description Pump body Support Impeller Diffuser Shaft Mechanical seal O-ring gasket Material Cast iron EN-GJL-200 Cast iron EN-GJL-200 Noryl GFN 2 Noryl GFN 2 AISI 303 stainless steel X 10 Cr NiS 18 9 Carbon/Ceramic NBR
Constructional features
Pump Pump body in cast iron. Motor support in die-cast aluminium, seal holder in stainless steel. Mechanical seal in carbon/ceramic. Shaft in stainless steel. Rotors, diffuser bodies and diffusers in technopolymer. Adjustment rings in stainless steel. Motor Continuous service asynchronous motor (2 poles) cooled by external fan. Built-in thermal and current overload protection and a capacitor permanently in circuit. Motor protection: Terminal box protection: Insulation class: Standard voltage: Tank Horizontal type, capacity 19 litres, with butyl diaphragm, complete with feet on the bottom and brackets for fixing the pump on top IP 44 IP 55 F 1 x 220-240 V, 50 Hz.
24
CHBasic PT
Technical data
Technical data
Operating range: Liquid quality requirements: Liquid temperature range: From 0.6 to 10.5 m3/h with head up to 63 metres Clean, free from solids or abrasive substances, non aggressive From 0C to +35C for domestic use (Safety regulations EN 60335-2-41) From 0C to +40C for other uses.
Maximum ambient temperature: +40C Maximum suction depth: Maximum operating pressure: Installation: Special executions on request: 8 metres (800 kPa) CHBasic 2 PT, CHBasic 3 PT, CHBasic 4 PT: 6 bar (600 kPa) Fixed in a horizontal position Other voltages and/or frequencies.
Curve conditions
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A.
CHBasic 2 PT
A1 D
0 H 0 [m] 55 50 45 400 40 35 30 25 200 100 0 20 15 10 5 0 0 0.0 1 0.4 2 3 0.8 4 1.2 5 6 1.6 7 2.0 Q [m/h] Q [l/s]
CHBasic 2 CHBasic 3 CHBasic 4
4 4
8 8
12 12
16
20 16
24 20
28 24
32 28
H1
P [kPa] 500
300
Electrical data Pump type CHBasic 2 PT CHBasic 3 PT CHBasic 4 PT 1 x 220-240 Voltage [V] P1
Max. [kW]
P2
[kW]
P2
[hp]
In
[A]
20
40
60
80
100
120 Q [l/min]
Pump type A CHBasic 2 PT CHBasic 3 PT CHBasic 4 PT 550 550 550 A1 405 425 425 B 270 270 270 D
Dimensions [mm] H 290 290 290 H1 200 200 200 L 330 330 330 DNA Rp 1 Rp 1 Rp 1 DNM Rp 1 Rp 1 Rp 1
Packing dimensions [mm] L/A 576 576 576 L/B 366 366 366 L/H 554 554 554
25
CHBasic PS
General data
CHBasic PS
6 3
Applications
Multistage horizontal centrifugal pump, featuring extremely silent running suitable for domestic use for water supply and pressurisation, irrigation of gardens and vegetable gardens, and moving water in general.
Gr7918
16 28
Material specification
Pos. 1 3 4 6 7 16 28 Description Pump body Support Impeller Diffuser Shaft Mechanical seal O-ring gasket Material Cast iron EN-GJL-200 Cast iron EN-GJL-200 Noryl GFN 2 Noryl GFN 2 AISI 303 stainless steel X 10 Cr NiS 18 9 Carbon/Ceramic NBR
Constructional features
Pump Pump body in cast iron. Motor support in die-cast aluminium, seal holder in stainless steel. Mechanical seal in carbon/ceramic. Shaft in stainless steel. Rotors, diffuser bodies and diffusers in technopolymer. Adjustment rings in stainless steel. Motor Continuous service asynchronous motor (2 poles) cooled by external fan. Built-in thermal and current overload protection and a capacitor permanently in circuit. Motor protection: Terminal box protection: Insulation class: Standard voltage: IP 44 IP 55 F 1 x 220-240 V, 50 Hz.
26
CHBasic PS
Technical data
Technical data
Operating range: Liquid quality requirements: Liquid temperature range: From 0.6 to 10.5 m3/h with head up to 63 metres Clean, free from solids or abrasive substances, non aggressive From 0C to +35C for domestic use (Safety regulations EN 60335-2-41) From 0C to +40C for other uses.
Maximum ambient temperature: +40C Maximum suction depth: Maximum operating pressure: Installation: Special executions on request: 8 metres (800 kPa) CHBasic 2 PS, CHBasic 3 PS, CHBasic 4 PS: 6 bar (600 kPa) Fixed in a horizontal position Other voltages and/or frequencies.
Curve conditions
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A.
CHBasic PS
0
A C DNM D DNM
4 4
8 8
12 12
16
20 16
24 20
28 24
32 28
P [kPa] 500
H 0 [m] 55 50 45 40 35 30 25 20 15 10 5
H1 H3 DNA
H2
G B
CHBasic 2
CHBasic 3
CHBasic 4
Electrical data Pump type CHBasic 2 PS CHBasic 3 PS CHBasic 4 PS 1 x 220-240 Voltage [V] P1
Max. [kW]
P2
[kW]
P2
[hp]
In
[A]
Pump type A CHBasic 2 PS CHBasic 3 PS CHBasic 4 PS 405 425 425 B 281 281 281 C 122 122 122 D 196 196 196 E 205 205 205 F 14 14 14
Dimensions [mm] G 111 111 111 H 238 238 238 H1 205 205 205 H2 200 200 200 H3 144 144 144 I 9 9 9 DNA Rp 1 Rp 1 Rp 1 DNM Rp 1 Rp 1 Rp 1
Packing dimensions [mm] L/A 449 449 449 L/B 309 309 309 L/H 244 244 244
Weight [kg] 14 17 17
27
CHBasic PC
General data
CHBasic PC
the membrane which gradually releases a spring. The sensors detect the movement, send a signal to the electronic unit which enables pump start-up. 3. Automatically stops the pump when the users stop drawing water. When the appliances are closed, under the effect of the rise in pressure within the hydraulic system, the membrane totally compresses the spring. This new situation is analysed by the sensors which send the unit a signal to stop the pump. The stop is timed in order to prevent the pump from being subjected to repeated starts caused by users opening and closing the appliances within a few seconds of each other. Furthermore, if boilers are supplied, the continuous delivery of hot water is guaranteed by timing the stops. 4. Instant pump start when one of the appliances is opened even with a minimum amount of water drawn. 5. In the event of leaks in the system (drips or small trickles) the device limits the number of cycles, prolonging pump running time by about 10 seconds. 6. It eliminates water hammering by means of a specific shock absorber which absorbs the effect. 7. Manual reset in the event of a breakdown in the hydraulic circuit or of overload protector intervention; in this case, after eliminating the cause, press the "RESET" button positioned on the terminal board cover for a few seconds until the "ALARM" LED switches off. 8. In the event of a power cut, automatic reset as soon as the power is restored. 9. The system is self-protected against overheating. When there is an excess in temperature inside the motor windings, this operation is carried out automatically. It is also restored automatically once the temperature has dropped below the level which guarantees operation without damage to the system.
Gr7916
Applications
Multistage horizontal centrifugal pump, featuring extremely silent running suitable for domestic use for water supply and pressurisation, irrigation of gardens and vegetable gardens, and moving water in general.
Operation
The pump is equipped with a Presscontrol (PC) which controls, manages and commands it, regulating its operation, limiting the number of starts and guaranteeing maximum pressure stability inside the hydraulic circuit in which it is installed. The automatic devices is the result of a series of studies conducted to optimise the efficiency of the system while preserving the structural features and sturdiness of existent devices. Automatic sets differ from the traditional systems equipped with a pressure switch based on pump starting and stopping as they avoid sudden variations and drops in pressure. They are basically equipped with a double control device, as built-in electrical circuit gathers the data regarding pressure and water flow in the system and processes them to allow the pump to operate under optimum performance conditions. The automatic device is supplied pre-installed on the pump, requires no type of regulation and considerably reduces overall dimensions by totally eliminating the bulky tanks used traditional installations.
Constructional features
Pump Pump body in cast iron. Motor support in die-cast aluminium, seal holder in AISI 304 steel. Mechanical seal in carbon/ceramic. Rotor shaft in AISI 304 steel. Rotors, diffuser bodies and diffusers in technopolymer. Adjustment rings in stainless steel. Motor Continuous service asynchronous motor (2 poles) cooled by external fan. Built-in thermal and current overload protection and a capacitor permanently in circuit. Motor protection: Terminal box protection: Insulation class: Standard voltage: IP 44 IP 55 F 1 x 220-240 V, 50 Hz.
28
CHBasic PC
Technical data
16 28
Material specification
Pos. 1 3 4 6 7 16 28 Description Pump body Support Impeller Diffuser Shaft Mechanical seal O-ring gasket Material Cast iron EN-GJL-200 Cast iron EN-GJL-200 Noryl GFN 2 Noryl GFN 2 AISI 303 stainless steel X 10 Cr NiS 18 9 Carbon/Ceramic NBR
29
CHBasic PC
Technical data
Technical data
Operating range: Liquid quality requirements: Liquid temperature range: From 0.6 to 10.5 m3/h with head up to 63 metres Clean, free from solids or abrasive substances, non aggressive From 0C to +35C for domestic use (Safety regulations EN 60335-2-41) From 0C to +40C for other uses.
Maximum ambient temperature: +40C Maximum suction depth: Maximum operating pressure: Installation: Special executions on request: 8 metres (800 kPa) CHBasic 2 PC, CHBasic 3 PC, CHBasic 4 PC: 6 bar (600 kPa) Fixed in a horizontal position Other voltages and/or frequencies.
Curve conditions
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A.
CHBasic PC
C DMN
0 H 0 [m] 55 50 45 400 300 200 100 0 40 35 30 25 20 15 10 5 0 0 0.0 1 0.4 2 3 0.8 4 1.2 5 6 1.6 7 2.0 Q [m/h] Q [l/s]
CHBasic 2 CHBasic 3 CHBasic 4
4 4
8 8
12 12
16
20 16
24 20
28 24
32 28
P [kPa]
DNA
500
F E A
I G B
Electrical data Pump type CHBasic 2 PC CHBasic 3 PC CHBasic 4 PC 1 x 220-240 Voltage [V] P1
Max. [kW]
P2
[kW]
P2
[hp]
In
[A]
20
40
60
80
100
120 Q [l/min]
Pump type A CHBasic 2 PC CHBasic 3 PC CHBasic 4 PC 406 425 425 B 212 212 212 C 122 122 122 E 207 207 207
Dimensions [mm] F 13.5 13.5 13.5 G 111 111 111 H 376 376 376 I 9 9 9 DNA Rp 1 Rp 1 Rp 1 DNM Rp 1 Rp 1 Rp 1
Packing dimensions [mm] L/A 524 524 524 L/B 248 248 248 L/H 309 309 309
Weight [kg] 14 16 16
30
NSBasic
Performance range
p [kPa]
700
H [m]
70 65
NSBasic
50 Hz
5-60
600
60 55
500
50 45
5-50
6-40 3-40
400
40 6-30 35 5-33
300
30 25 4-23
200
20 15
13-18
100
10 5
0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Q [m/h]
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
Q [l/s]
31
NSBasic
General data
Gr7897
16 7
Applications
Single impeller centrifugal pump designed for lifting water in domestic, civil, industrial and agricultural installations and for decanting, mixing and irrigating uses.
Material specification
Description 1 3 4 7 Pump body Support Impeller Shaft Material Cast iron EN-GJL-200 Cast iron EN-GJL-200 Noryl GFN 2 X 12 CrNi 1810 X 10 CrNi 1809 NBR NSBasic 4-23 - NSBasic 13-18 NSBasic 5-33 Pump types
Constructional features
Pump Cast iron pump body and motor support treated against corrosion also on the inner surface. Technopolymer and cast iron impeller. Carbon/ceramic mechanical seal mounted on stainless steel rotor shaft extension. Motor Induction motor, closed and cooled with external fan. Rotor mounted on oversized greased sealed-for-life ball bearing to ensure silent running and long life. Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phase version. The user is responsible for the protection in the three-phase version. Manufactured according to standard EN 60335-2-41. Motor protection: Terminal box protection: Insulation class: Standard voltage: IP 44 IP 55 for the single-phase version F 1x220-240 V, 50 Hz 3x220-240/380-415 V, 50 Hz.
32
NSBasic
Technical data
Technical data
Operating range: Liquid quality requirements: Liquid temperature range: Maximum ambient temperature: Maximum operating pressure: Installation: Special versions on request: From 1.8 to 16.8 m3/h with head up to 34 metres Clean, free from solids or abrasive substances, non viscous, non aggressive, noncrystallized, chemically neutral, close to the characteristics of water. NSBasic 4-23, NSBasic 5-33, NSBasic 13-18: +40C NSBasic 4-23, NSBasic 5-33, NSBasic 13-18: 6 bar (600 kPa) from -10C to + 50C
Fixed in a horizontal or vertical position, as long as the motor is above the pump Other voltages and/or frequencies.
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A.
NSBasic 4-23
12
16
20
24
Q [US GPM]
0 P [kPa] H [m] 20
12
16
20
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5
Q [m/h]
P2
Eta [%] 40 20 0
Electrical data Pump type NSBasic 4-23 Voltage [V] 1x220-240 P1 P2 P2 Max. [kW] [kW] [hp] 0.65 0.37 0.5 In [A] 3.0 Capacitor [F] [Vc] 10 450 0 10 20 30 40 50 60 70 80 90 Q [l/min]
0.5 2.3/1.3
DNA Rp 1
DNM Rp 1
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [m/h] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 Q [l/s]
33
NSBasic
Technical data
NSBasic 5-33
0 4 8 12 16 20 24 28 32 36 Q [US GPM]
0 P [kPa] 320 240 160 80 0 20 10 0 P2 [kW] 0.8 0.4 0.0 0 0.0 0 H [m] 30
12
16
20
24
28
Q [m/h]
P2 Eta
Eta [%] 40 20 0
1 0.4
3 0.8
4 1.2
6 1.6
7 2.0
20
40
60
80
100
120
Q [l/min]
DNA Rp 1
DNM Rp 1
NSBasic 13-18
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 Q [US GPM]
10 15 20 25 30 35 40 45 50 55 60
10
12
14
16
Q [m/h]
P2 Eta
Eta [%] 40 20 0
2 0.5
4 1.0
6 1.5 2.0
16 4.5
Q [m/h] Q [l/s]
Electrical data Pump type NSBasic 13-18 Voltage [V] 1x220-240 P1 P2 P2 Max. [kW] [kW] [hp] 1.1 1.1 0.75 0.75 1 1 In [A] 4.6 3.6/2.1 Capacitor [F] [Vc] 20 450 0 40 80 120 160 200 240 Q [l/min]
DNA Rp 1
DNM Rp 1
Vol [m 3] 0.024
Weight [kg] 14
34
Electrical data
NSBasic
General data
4 28
16
Applications
Muliti-stage centrifugal pump with opposed twin impellers. Designed for use in pressurisation units for water supply systems and for supplying pressurised tanks. Suitable also for sprinkling, irrigation and other water supply application.
Material specification
Description 1 3 Pump body Support Material Cast iron EN-GJL-200 Cast iron EN-GJL-200 Noryl GFN 2 Ultem 2300 NSBasic 3-40 - NSBasic 5-50 NSBasic 6-30 - NSBasic 6-40 NSBasic 5-60 Pump types
Impeller
Constructional features
Pump Cast iron pump body and motor support treated against corrosion also on the inner surface. Technopolymer and cast iron impeller. Carbon/ceramic mechanical seal mounted on stainless steel rotor shaft extension. Motor Induction motor, closed and cooled with external fan. Rotor mounted on oversized greased sealed-for-life ball bearing to ensure silent running and long life. Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phase version. The user is responsible for the protection in the three-phase version. Manufactured according to standard EN 60335-2-41. Motor protection: Terminal box protection: IP 44 IP 55 for the single-phase version up to and including 0.75 kW F 1x220-240 V, 50 Hz 3x220-240/380-415 V, 50 Hz.
Shaft
Stainless steel ANSI X12 CrNi 1810 Carbon/Ceramic Impregnated Cellulose Cast iron EN-GJL-200
Gr7928
35
NSBasic
Technical data
Technical data
Operating range: Liquid quality requirements: Liquid temperature range: Maximum ambient temperature: Maximum operating pressure: Installation: Special versions on request: From 1.5 to 10.8 m3/h with head up to 60 metres. clean, free from solids or abrasive substances, non viscous, non aggressive, non crystallized, chemically neutral, close to the characteristics of water. NSBasic 3-40, NSBasic 5-50, NSBasic 6-30, NSBasic 6-40: from 10C to + 50C NSBasic 5-60: from 15C to + 110C +40C NSBasic 3-40, NSBasic 5-50, NSBasic 6-30, NSBasic 6-40: 6 bar ( 600 kPa) NSBasic 5-50, NSBasic 5-60: 8 bar ( 800 kPa) Fixed in a horizontal or vertical position, as long as the motor is above the pump. Other voltages and/or frequencies.
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A.
NSBasic 3-40
0 4 8 12 16 20 24 Q [US GPM]
12
16
20
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5
Q [m/h]
P2 Eta
Eta [%] 40 20 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [m/h] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 Q [l/s]
10
20
30
40
50
60
70
80
90
Q [l/min]
Dimensions [mm] A 342 B 180 C 76 D 148 E 72 F 15 G 148 I 9.5 H 235 H1 100 H2 135
DNA Rp 1
DNM Rp 1
36
Electrical data
NSBasic
Technical data
NSBasic 5-50
0 4 8 12 16 20 24 28 32 Q [US GPM]
0 P [kPa] 400 300 200 100 0 P2 [hp] 1.6 0.8 0.0 H [m] 50 40 30 20 10 0 P2 [kW] 1.6 0.8 0.0 0
12
16
20
24
28
Q [m/h]
Eta [%] 40 20
P2 Eta
In [A] 8.3
1.5 6.0/3.5
Dimensions [mm] E 69 69 F 15 15 G 165 165 I 11.5 11.5 H 268 268 H1 118 118 H2 150 150
DNA Rp 1 Rp 1
DNM Rp 1 Rp 1
Packing dimensions [mm] L/A 415 415 L/B 235 234 L/H 295 295
NSBasic 5-60
0 4 8 12 16 20 24 28 32 36 40 Q [US GPM]
12
16
20
24
28
32
P2 [hp] 2 1 0
Q [m/h]
Eta [%] 40 20
P2 Eta
Electrical data Pump type NSBasic 5-60 Voltage [V] 1x220-240 P1 P2 P2 Max. [kW] [kW] [hp] 2.7 2.5 1.8 1.8 2.5 In [A] 12.8 Capacitor [F] [Vc] 40 450 0 20 40 60 80 100 120 140 Q [l/min]
2.5 8.4/4.8
Dimensions [mm] A 370 B 210 C 75 D 144 E 69 F 15 G 165 I 11.5 H 268 H1 118 H2 150
DNA Rp 1
DNM Rp 1
Electrical data
37
NSBasic
Technical data
NSBasic 6-30
0 4 8 12 16 20 24 28 32 36 40 44 48 Q [US GPM]
12
16
20
24
28
32
36
40
10
11 Q [m/h]
P2 Eta
Eta [%] 40 20 0
0.0 0 0.0 1 0.4 2 3 0.8 4 5 6 1.2 1.6 7 8 9 2.0 2.4 10 11 Q [m/h] 2.8 Q [l/s]
Pump type
20
40
60
80
100
120
140
160
180Q [l/min]
NSBasic 6-30
3x220-240/380-415 1.56
DNA Rp 1
DNM Rp 1
NSBasic 6-40
0 4 8 12 16 20 24 28 32 36 40 44 48 Q [US GPM]
12
16
20
24
28
32
36
40
10
11 Q [m/h]
P2 Eta
Eta [%] 40 20 0
0.0 0 0.0 1 0.4 2 3 0.8 4 5 6 1.2 1.6 7 8 9 2.0 2.4 10 11 Q [m/h] 2.8 Q [l/s]
Pump type
In [A] 9 6.2/3.6
20
40
60
80
100
120
140
160
180Q [l/min]
NSBasic 6-40
3x220-240/ 380-415
Dimensions [mm] E 179 179 F 20 20 G 145 145 I 11 11 H 233 233 H1 108 108
DNA Rp 1 Rp 1
DNM Rp 1 Rp 1
Packing dimensions [mm] L/A 510 415 L/B 234 234 L/H 285 295
38
Electrical data
Electrical data
KPBasic
KPBasic
Performance range
p [kPa]
100
H [m]
10.5 10.0 9.5 600 (A)
KPBasic
50 Hz
90
9.0 8.5
80
8.0 7.5
70
7.0 6.5
300 A
60
50
5.0 4.5
40
4.0 3.5
30
3.0 2.5
20
2.0 1.5
10
1.0 0.5
0.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Q [m/h]
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
Q [l/s]
39
KPBasic
General data
KPBasic
Supplied standard with 10 metres of H05 RN-F power cable. Supplied standard with 10 metres of H05 RN-F power cable. Note: 5 m cable om request. Supplied standard with 10 metres of H07 RN-F power cable. Supplied standard with 10 metres of H07 RN-F power cable. Note: 5m cable on request.
Standard voltage:
Applications
The submersible pump from the KPBasic series is designed mainly for automatically operated fixed applications in domestic use, draining basements and garages which are subject to flooding. Thanks to its compact, easy to handle design, it can also be used as a portable pump for emergencies such as lifting water from tanks or rivers, emptying swimming pools, fountains, excavations and underpasses. It is also ideal for gardening and hobbies in general. The level switch allows fixed installation and guarantees automatic pump operation.
Table of performance ranges and possible applications DNM connections Flow rate Q [m3/h] Head H [m] Temperature t [ C] Rain water Clean waste water
o
29 1 78 79 32
Pos. 1 4 29 32 Descriptions Pump body impeller O-ring gasket Stop ring Motor 54 - Top body - Shaft 78 79 Pressure disc Suction grid Stainless steel AISI 304 X5 CrNi 1810 Stainless steel AISI 304 X5 CrNi 1810 Noryl GFN 2 Noryl GFN 2 Noryl GFN 2 Noryl GFN 2 NBR Stainless steel 12E
Constructional features
Pump Water-resistant technopolymer pump body, impeller, top body and suction grid. Stainless steel motor casing, rotor shaft and screws. Triple "O" ring seals interposed with oil chamber. Motor Continous duty submersible induction motor. Stator fitted in an airtight stainless steel casing covered by a top body which encases cabling, microswitch and capacitor. Rotor mounted on oversized greased sealedfor-life ball bearings selected to guarantee silent running and long life. Built-in thermal and current overload protection and a capacitor which is permanently in circuit in the single-phase version.
4
Materials
40
54 73
KPBasic
Technical data
Technical data
Operation range: Liquid quality requirements: Granulometric passage though the suction grid: From 1 to 16 m3/h with head up to 10.2 metres Grey water without fibres KPBasic 200 KPBasic 300A KPBasic 600 KPBasic 600A KPBasic 200 KPBasic 300A KPBasic 600 KPBasic 600A From 0C to +35C 7 metres 1 minute Type name extension: A Other voltages and/or frequencies Fixed or portable in a vertical position. The minimum pit dimensions for fixed installation with automatic operation are indicated in the drawing. 5 mm 10 mm 10 mm 10 mm 8 mm 85 mm 38 mm 175 mm
Liquid temperature range: Maximum immersion: Maximum dry running time: Automatic float switch: Special versionson request: Installation:
Curve conditions
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A.
KPBasic 300 A
Minimum dimension for the pit for KPBasic 300 A with automatic float switch
KPBasic 600 A
Minimum dimension for the pit for KPBasic 600 A with automatic float switch
400
500
400
400
41
KPBasic
Technical data
KPBasic 200
0 4 8 12 16 20 24 28 32 36 40 44 Q [US GPM] 0 P [kPa] 80 60 40 20 0 P2 [hp] 0.2 0.1 0.0 H [m] 8 6 4 2 0 P2 [kW] 0.2 0.1 0.0 0 0.0 1 0.4 0 1 2 3 4 5 6 7 8 9 10 Q [m/h] 4 8 12 16 20 24 28 32 36 Q [IMP GPM] H [ft] 25 20 15 10 5 0 Eta [%] 40
KPBasic 300A
0 4 8 12 16 20 24 28 32 36 40 44 48 52 56 Q [US GPM] 0 P [kPa] 80 60 40 20 0 P2 [hp] 0.2 0.1 0.0 H [m] 8 6 4 2 0 P2 [kW] 0.2 0.1 0.0
Eta
12
16
20
24
28
32
10 11 12
Q [m/h]
P2 Eta
P2
Eta [%] 40 20 0
4 5 6 1.2 1.6
7 8 9 2.0 2.4
20
40
60
80
100
120
140
160 Q [l/min]
20
40
60
Liv.min.
H2
Liv.max.
H1
E B A D
Electrical data Pump type KPBasic 200 KPBasic 300A Voltage [V] 1x220-240 1x220-240 P1 Max. [W] 350 350 P2 [kW] 0.22 0.22 P2 [hp] 0.3 0.3 In [A] 1.5 1.5 Capacitor [F] 8 8 [Vc] 450 450
Dimensions [mm] A 185 185 B 140 140 D 225 225 E 82 82 H 266 275 H1 390 390 H2 38,5 47,5
DNM Rp 1 Rp 1
Packing dimensions [mm] L/A 207 207 L/B 227 227 L/H 312 312
42
KPBasic
Technical data
10 15 20 25 30 35 40 45 50 55 60
2 0.5
4 1.0
6 1.5 2.0
8 2.5
16 4.5
Q [m/h] Q [l/s]
B A D
40
80
120
160
200
240
Q [l/min]
Electrical data Pump type KPBasic 600 KPBasic 600A KPBasic 600 Voltage [V] 1x220-240 1x220-240 3x380-415 P1 Max. [W] 800 800 800 P2 [kW] 0.55 0.55 0.55 P2 [hp] 0.75 0.75 0.75 In [A] 3.4 3.4 3.4 Capacitor [F] 14 14 [Vc] 450 450 -
Dimensions [mm] A 200 200 B 160 160 D 225 225 E 90 90 H 376 376 H1 490 490 H2 73 73
DNM Rp 1 Rp 1
Packing dimensions [mm] L/A 207 207 L/B 227 227 L/H 422 422
Liv.min.
H2
Liv.max.
H1
43
PFBasic
PFBasic
Performance range
p [kPa]
600
H [m]
60
PF(P)Basic
50 Hz
PFPBasic 2-50
55 500
50 PFBasic 2-50 45
400
40
35 300
PFBasic 1-30
30
25
200
20
15
100
10
0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8
Q [m/h] Q [l/s]
TM02 8935 1804
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
44
PFBasic
General data
PFBasic
1 28 4
16
Applications
Peripheral centrifugal pump with compact dimensions. Able to generate high heads and suitable for domestic installations, water supply systems, light gardening applications, draining and filling cisterns, as well as light industrial uses such as feeding pressurized boilers (anticondensation).
Material specification
Pos. 1 4 7 16 28 Description Pump body Impeller Shaft Mechanical seal O-ring gasket Material Cast iron EN-GJL-200 Brass PCu Zn 40 Pb2 5705-65 Stainless steel AISI 416 X12 CrS 13 Carbon/ceramic NBR rubber
Constructional features
Pump Cast iron pump body and motor support with brass wear disc. Brass impeller. Carbon/ceramic mechanical seal. Motor Induction motor, closed and cooled with external ventilation. Rotor mounted on oversized greased sealed-forlife ball bearings to ensure silent running and long life. The motor incorporates a built-in thermal and current overload protection as well as a capacitor, switched on permanently. Manufactured according to standard EN 60335-2-41. Motor protection: Terminal box protection: Insulation class: Standard voltage: IP 44 IP 55 F Single-phase 220-240 V, 50 Hz.
GR7901
45
PFBasic
Technical data
Technical data
Operating range: Pumped liquid: Liquid temperature range: From 0.3 to 2.7 m3/h with heads up to 53 metres. Cclean, free from solids or abrasive substances, non viscous, non aggressive, non crystallized, chemically neutral, close to the characteristics of water. from 0C to +35C for domestic use (EN 60335-2-41) From 10C to +50C for other uses. Maximum ambient temperature: +40C Maximum operating pressure: Installation: - PFBasic 1-30: 6 bar (600 kPa) - PFBasic 2-50: 10 bar (1000 kPa) Fixed in the horizontal position.
The performance curves are based on a kinematic viscosity value of 1 mm/s and a density equal to 1000 kg/m3. Curve tolerances according to ISO 9906, annex A.
p [kPa] H [m] 56 52 480 400 320 240 160 80 0
TM02 9091 1804
2-50
PFBasic
50 Hz
ISO 9906 Annex A
0.6
Q [l/s]
Electrical data
Model PFBasic 1-30 PFBasic 2-50 Voltage [V] 1 x 220-240 1 x 220-240 P1 max. [kW] 0.47 0.86 P2 [kW] 0.3 0.6 P2 [hp] 0.4 0.8 In [A] 2 3.8 Capacitor [F] 8 12.5 [Vc] 450 450
46
2.0
2.4 Q [m/h]
PFPBasic
General data
PFPBasic 2-50
1 3 28 7
Gr7900General data
16
Applications
Self-priming pump with side liquid channel and starshaped impeller, with excellent suction capacities even in unfavourable operating conditions such as the presence of air bubbles or lack of continuity in the sucked liquid. Used in domestic, agricultural civil and industrial installations.
Materials
Pos. 1 3 4 7 Description Pump body Motor support Impeller Shaft Mechanical seal O-ring gasket Material Cast iron EN-GJL-200, with brass wear ring PCuZn 40 Pb2 5705/65 Brass PCu Zn 40 Pb2 5705/65 Brass PCu Zn 40 Pb2 5705/65 Stainless steel AISI 416 X12 CrS 13 Carbon/ceramic FKM
Constructional features
Pump Cast iron pump body with brass pressure disc. Motor support and impeller completely made of brass, to avoid the risk of blockage. Carbon/ceramic mechanical seal. Stainless steel motor shaft. Motor Asynchronous motor, cooled by external fan. Rotor mounted on oversized, greased and sealed-for-life ball bearings to ensure quiet operation and long life. The single-phase version has built-in thermal and current overload protection. Manufactured according to standard EN60335-2-41. Motor protection: Insulation class: Standard voltage: IP 44 IP 55 terminal board protection F Single-phase 220-240 V, 50 Hz. Other voltages and frequencies are available on request.
16 28
47
PFPBasic
Technical data
Operating conditions
Operating range: Pumped liquid: Liquid temperature range: From 0.5 to 2.7 m3/h with heads up to 53 metres. Clean, free from solids or abrasive substances, non-aggressive, noncrystallized, chemically neutral, similar to the characteristics of water. From 10C to +80C
Maximum ambient temperature: +40C Maximum operating pressure: Installation: 10 bar (1000 kPa) Fixed in the horizontal position.
The performance curves are based on a kinematic viscosity value of 1 mm/s and a density equal to 1000 kg/m3. Curve tolerances according to ISO 9906, annex A.
p [kPa] H [m] 56 52 480 400 320 240 160 80 0
TM02 9092 1804
PFPBasic 2-50
50 Hz
ISO 9906 Annex A
0.6
0.8 Q [l/s]
Electrical data
Model PFPBasic 2-50 Voltage [V] 1 x 220-240 P1 max. [kW] 1.05 P2 [kW] 0.75 P2 [hp] 1 In [A] 4.7 Capacitor F 20 Vc 450
48
2.4
2.8 Q [m/h]
49
50
51
Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence
96548246 0804 - c1
GB
Subject to alterations.