GRUNDFOS DATA BOOKLET

Grundfos Basic
50 Hz

Contents

JPBasic
Performance range General data Applications Constructional features Material specification Technical data Curve conditions Page Page Page Page Page Page Page 3 4 4 4 5 5 5

CHBasic PS
General data Applications Constructional features Material specification Technical data Curve conditions Page Page Page Page Page Page 26 26 26 26 27 27

JPBasic PT
General data Applications Constructional features Material specification Technical data Page Page Page Page Page 10 10 10 10 11

CHBasic PC
General data Applications Operation Constructional features Material specification Technical data Curve conditions Page Page Page Page Page Page Page 28 28 28 28 29 30 30

JPBasic PS
General data Page 12

NSBasic
Performance range General data NSBasic single impeller pumps Applications Constructional features Material specification Technical data NSBasic twin impeller pumps Applications Constructional features Material specification Technical data Page Page Page Page Page Page Page Page Page Page Page Page 31 32 32 32 32 32 33 35 35 35 35 36

JPBasic PC
General data Applications Operation Technical data Page Page Page Page 13 13 13 15

JDBasic
General data Applications Constructional features Material specification Technical data Instructions for conversion Page Page Page Page Page Page 16 16 16 16 17 18

KPBasic
Performance range General data Applications Constructional features Technical data Curve conditions Page Page Page Page Page Page 39 40 40 40 41 41

CHBasic
Performance range General data Applications Constructional features Material specification Technical data Curve conditions Page Page Page Page Page Page Page 19 20 20 20 20 21 21

PFBasic
Performance range General data Applications Constructional features Material specification Technical data Page Page Page Page Page Page 44 45 45 45 45 46

CHBasic PT
General data Applications Constructional features Material specification Technical data Curve conditions Page Page Page Page Page Page 24 24 24 24 25 25

PFPBasic
General data Applications Constructional features Materials Technical data Page Page Page Page Page 47 47 47 47 48

JPBasic

JPBasic

Performance range
p [kPa] H [m]
65 600

JPBasic
50 Hz

60

55 500

50

45 400

40 5 35 7

300

30 4

10 9

25 200

20

15 2 100 10

0
TM02 8936 1804

10

Q [m/h]
3.0

0.0

0.5

1.0

1.5

2.0

2.5

Q [l/s]

JPBasic

General data

JPBasic 2, JPBasic 3, JPBasic 4

JPBasic 9, JPBasic 10

Gr7903

Applications
Self-priming centrifugal pump with excellent suction capacity even when there are air bubbles and small sandy impurities in the water. Used especially for supplying water to domestic systems. Ideal for use in small-scale agriculture and gardening, limited industrial services and wherever selfpriming operation is necessary.

JPBasic 5, JPBasic 7

Constructional features
Pump Cast iron pump body and motor support in cast iron treated against corrosion also on the inner surface. Technopolymer impeller, diffuser venturi tube and sand tube. Stainless steel pressure disc. Carbon/ceramic mechanical seal mounted on stainless steel rotor shaft extension. Motor Asynchronous motor cooled with external fan. Rotor mounted on greased sealed-for-life ball bearings, selected to ensure silent running and a long life. Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phase version. The user is responsible for protection in the three-phase version. Motor protection: IP 44 Terminal box protection: IP 55 Insulation class: F Standard voltage: 1 x 220-240 V, 50 Hz 3 x 220-240/380-415 V, 50 Hz.
Gr7917

Gr7921

JPBasic

Technical data

Material specification
Pos. 1 3 4 6 7 8 16 28 Description Pump body Support Impeller Diffuser Shaft Venturi tube and nozzle Mechanical seal O-Ring gasket Material Cast iron EN-GJL-200 Cast iron EN-GJL-200 Noryl GFN 2 Noryl GFN 2 AISI 303 stainless steel X 10 Cr NiS 18 9 * Noryl GFN 2
TM02 8459 0204

6 28

Carbon/Ceramic NBR

* JPBasic 1, JPBasic 2, JPBasic 4: X 12 Cr S 13


16 4 7

Technical data
Operating range: Liquid quality requirements: Liquid temperature range: From 0.6 to 10.5 m3/h with head up to 63 metres Clean, free from solids or abrasive substances, non aggressive From 0C to +35C for domestic use (Safety regulations EN 60335-2-41) From 0C to +40C for other uses.

Maximum ambient temperature: +40C Maximum suction depth: Maximum operating pressure: Installation: Special executions on request: 8 metres JPBasic 2, JPBasic 3, JPBasic 4: JPBasic 5, JPBasic 7, JPBasic 9, JPBasic 10: Fixed in a horizontal position Other voltages and/or frequencies. 6 bar (600 kPa) 7.5 bar (750 kPa)

Curve conditions
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A.

Technical data

JPBasic

JPBasic 2
A A1 C DNA DNM

0 0

2 2

4 4

6 6

8 8

10

12 10

Q [US GPM] Q [IMP GPM] H [ft] 120 100 80

P [kPa] 400 320 240 160 80 0

H [m] 40 35 30 25 20 15 10 5 0

H3

TM02 8444 0204

I G B

8 7 6

60
5 4 3 2

40 20 0

Electrical data Pump type Voltage [V] 1 x 220-240 P1


Max. [kW]

0.4

0.6

P2
[kW]

P2
[hp]

In
[A]

Capacitor [F] [Vc] 12.5 450 0 10 20 30 40 Q [l/min]

JPBasic 2

0.72 0.44 0.6

3.12

3 x 220-240/380-415 0.67 0.44 0.6 2.1/1.2

Pump type JPBasic 2

Dimensions [mm] A 395 A1 390 B 178 C 108 E 192 F 14 G 111 H 200 H3 144 I 9 DNA Rp 1 DNM Rp 1

Packing dimensions [mm] L/A 470 L/B 240 L/H 240

Vol [m3] 0.027

Weight [kg] 10.9

JPBasic 3
A A1 C DNA DNM

0 0

2 2

4 4

6 6

10 8

12 10

14 Q [US GPM] Q [IMP GPM] H [ft] 140 120 100 80

P [kPa] 400
H

H [m] 45 40 35 30 25 20

H3

320

TM02 8444 0204

240 160 80 0

I G B

7 6 5 4 3 2

60 40 20 0

15 10 5 0 0.0 0.0 0.4 0.8 0.2 1.2 1.6 0.4

Electrical data Pump type Voltage [V] 1 x 220-240 3 x 220-240/380-415 P1 Max. [kW] 0.85 0.86 P2
[kW]

P2
[hp]

In
[A]

Capacitor [F] [Vc] 12.5 450 0 10 20 30 40 50 Q [l/min]

JPBasic 3

0.6 0.6

0.8

3.8

0.8 2.8/1.6

Pump type JPBasic 3

Dimensions [mm] A 395 A1 390 B 178 C 108 E 192 F 14 G 111 H 200 H3 144 I 9 DNA Rp 1 DNM Rp 1

Packing dimensions [mm] L/A 470 L/B 240 L/H 240

Vol [m3] 0.027

Weight [kg] 11

TM02 9024 1304

2.0 2.4 0.6

2.8 0.8

Q [m/h] Q [l/s]

TM02 9023 1304

0.0 0.0

0.4

0.8 0.2

1.2

1.6

2.0

2.4

Q [m/h] Q [l/s]

Technical data

JPBasic

JPBasic 4
A A1 C DNA DNM

0 0

2 2

4 4

6 6

10 8

12 10

14 Q [US GPM] Q [IMP GPM] H [ft] 160 140 120 100

P [kPa]

H [m] 50 45 40 35 30 25

H3

400 300

TM02 8444 0204

I G B

200 100 0

80
7 6 5 4 3 2

20 15 10 5 0 0.0 0.0 0.4 0.8 0.2 1.2 1.6 0.4

60 40 20 0

Electrical data Pump type Voltage [V] 1 x 220-240 P1 Max. [kW] P2 P2 1 1 In


[A]

Capacitor [F] [Vc] 16 450 0 10 20 30 40 50 Q [l/min]

[kW] [hp]

JPBasic 4

1.13 0.75

5.1 3.3/1.9

3 x 220-240/380-415 1.04 0.75

Pump type JPBasic 4

Dimensions [mm] A 414 A1 409 B 178 C 108 E 197 F 14 G 111 H 213 H3 144 I 9 DNA Rp 1 DNM Rp 1

Packing dimensions [mm] L/A 470 L/B 240 L/H 240

Vol [m3] 0.027

Weight [kg] 16.2

JPBasic 9
A C DNA
P [kPa] 400 H [m] 40 35 300 30 25 120 100 80 60 40
8 7 6 5 4

0 0

4 4

8 8

12

16 20 24 28 32 36 40 44 48 12 16 20 24 28 32 36 40

Q [US GPM] Q [IMP GPM] H [ft]

H1

I G B

TM02 8464 0204

200

20 15

100

10 5
3 2 1

20 0

0 0 0.0 1 0.4 2 3 0.8 4 5 6 1.2 1.6 7 8 9 2.0 2.4

Electrical data Pump type Voltage [V] 1 x 220-240 JPBasic 9 3 x 220-240/ 380-415 P1
Max. [kW]

P2
[kW]

P2
[hp]

In
[A]

Capacitor [F] 31.5 [Vc] 450 0 20 40 60 80 100 120 140 160 180Q [l/min]

2 2

1.5 1.5

2 2

9 6.8/3.9

Pump type JPBasic 9

Dimensions [mm] A 521 B 214 C 151 E 282 F 20 G 160 I 11 H 227 H1 175 DNA Rp 1 DNM Rp 1

Packing dimensions [mm] L/A 612 L/B 248 L/H 279

Vol [m3] 0.042

Weight [kg] 27

TM02 9028 1304

10 11 Q [m/h] 2.8 Q [l/s]

TM02 9025 1304

2.0 2.4 0.6

2.8 0.8

Q [m/h] Q [l/s]

Technical data

JPBasic

JPBasic 10
0
A A1 C

4 4

8 8

12

16 20 24 28 32 36 40 44 48 12 16 20 24 28 32 36 40

Q [US GPM] Q [IMP GPM] H [ft] 160 140 120 100 80

DNA

DNM

P [kPa]

H [m] 50 45 40 35 30 25 20 15 10 5 0

H3

400 300

I G B

TM02 8464 0204

200 100 0

60
7

40
6 5 4 3 2 1

20 0

Electrical data Pump type Voltage [V] 1 x 220-240 JPBasic 10 3 x 220-240/ 380-415 P1
Max. [kW]

0.4

P2
[kW]

P2
[hp]

In
[A]

Capacitor [F] 40 [Vc] 450 0 20 40 60 80 100 120 140 160 180Q [l/min]

2.7 2.7

2.2 2.2

3 3

12 8.5/4.9

Pump type JPBasic 10

Dimensions [mm] A 595 B 214 C 151 E 282 F 20 G 160 I 11 H 235 H1 175 DNA Rp 1 DNM Rp 1

Packing dimensions [mm] L/A 657 L/B 248 L/H 279

Vol [m3] 0.045

Weight [kg] 31.5

JPBasic 5
0
Z C A B DNM

2 2

4 4

6 6

10 8

12 10

14 12

16 14

18

20 16

Q [US GPM] Q [IMP GPM] H [ft] 200 160 120

P [kPa] 600

H [m] 60 50 40 30 20 10 0

V H H

DNA

500
H2

DNE

400

H1

H1

TM02 8462 0204

X A E

I G

300 200 100 0

6 7 5 4 3 2 1

80 40 0

Electrical data Pump type Voltage [V] 1 x 220-240 JPBasic 5 3 x 220-240/ 380-415 P1
Max. [kW]

P2 1.1 1.1

P2 1.5 1.5

In
[A]

Capacitor [F] [Vc] 31.5 450 0 10 20 30 40 50 60 70 Q [l/min]

[kW] [hp]

1.6 1.6

7.2 5.2/3.0

Pump type JPBasic 5

Dimensions [mm] A 558 B 210 C 221 E 350 F 20 G 145 I 11 H 255 H1 158 DNA Rp 1 DNM Rp 1

Packing dimensions [mm] L/A 612 L/B 248 L/H 279

Vol [m3] 0.045

Weight [kg] 31

TM02 9026 1304

0.0 0.0

0.5 1.0 1.5 0.2 0.4

2.0 2.5 3.0 0.6 0.8

3.5 4.0 4.5 Q [m/h] 1.0 1.2 Q [l/s]

TM02 9029 1304

0 0.0

3 0.8

4 5 6 1.2 1.6

7 8 9 2.0 2.4

10 11 Q [m/h] 2.8 Q [l/s]

Technical data

JPBasic

JPBasic 7
0
Z C A B DNM

4 4

8 8

12 12

16

20 16

24 20

28 24

32 28

Q [US GPM] Q [IMP GPM] H [ft] 200 160

P [kPa] 600

H [m] 60 50 40 30 20 10

V H H

DNA

500 400
H2

DNE

H1

H1

8 7

TM02 8462 0204

120
6 5 4 3 2

X A E

I G

300 200 100 0

80 40
1

0 0 0.0 1 0.4 2 3 0.8 4 1.2 5 6 1.6 7 2.0 Q [m/h] Q [l/s]

Electrical data Pump type Voltage [V] 1 x 220-240 JPBasic 7 3 x 220-240/ 380-415 P1
Max. [kW]

P2
[kW]

P2
[hp]

In
[A]

Capacitor [F] 40 [Vc] 450 0 20 40 60 80 100 120 Q [l/min]

2.2 2.2

1.85 1.85

2.5 2.5

10 6.9/4.0

Pump type JPBasic 7

Dimensions [mm] A 632 B 210 C 221 E 350 F 20 G 145 I 11 H 255 H1 158 DNA Rp 1 DNM Rp 1

Packing dimensions [mm] L/A 657 L/B 248 L/H 279

Vol [m3] 0.045

Weight [kg] 35

TM02 9027 1304

JPBasic PT

General data

JPBasic PT

Tank Horizontal type, capacity 19 litres, with butyl diaphragm, complete with feet on the bottom and brackets for fixing the pump on top.
8 1 6 28 3

TM02 9060 1704General data

16

Applications
Automatic water lifting and pressure boosting sets, particularly suitable for domestic use, small installations for civil, industrial and agricultural use, washing systems and hobbies. The characteristics of the JPBasic-pumps are that they are self-priming electric pumps which can operate even when there is air, gas and small quantities of sand in the water. The set is composed of a diaphragm tank with capacity 19 litres, pressure switch for automatic operation, pressure gauge, JPBasic electric pump complete with power cable and plug, kit for coupling the pump and the tank, all assembled and ready for installation. Note: Vertical 8 litres or 18 litres tanks are used in some markets.

Material specification
Pos. 1 3 4 6 7 8 16 28 Support Impeller Diffuser Shaft Venturi tupe and nozzle Mechanical seal O-Ring gasket Description Pump body Material Cast iron (EN-GJL-200) Cast iron (EN-GJL-200) Noryl GFN 2 Noryl GFN 2 Stainless steel AISI 416 X12 CrS 13 Noryl GFN 2 Carbon/Ceramic NBR

Components in contact with the liquid.

Constructional features
Pump Cast iron pump body and motor support. Technopolymer impeller, diffuser, Venturi tube and sand guard. Stainless steel pressure discs. Carbon/ceramic mechanical seal. Motor Induction motor, closed and cooled with external ventilation. Rotor mounted on oversized greased sealed-forlife ball bearings, to ensure silent running and a long life. Built-in thermal and current overload protection and a capacitor permanently in circuit. Manufactured according to standard EN 60335-2-41. Motor protection: Insulation class: Standard voltage: IP 44 F 1 x 220-240 V, 50 Hz.

10

TM02 8459 3204

JPBasic PT

Technical data

Technical data
Operating range: Liquid quality requirements: Liquid temperature range: Up to 3.6 m3/h with head up to 51 metres. Clean, free from solids or abrasive substances, non viscous, non aggressive, non crystallized, chemically neutral, close to the characteristics of water. From 0C to +35C for domestic use (Safety regulations EN 60335-2-41) From 0C to +40C for other uses.

Maximum ambient temperature: +40C Maximum operating pressure: Installation: 6 bar (600 kPa) Fixed in a horizontal position.

JPBasic PT
A1 D
0 0 2 2 4 4 6 6 8 10 8 12 10 14 Q [US GPM] Q [IMP GPM] H [ft] 160 140 120
JPBasic 4

H1

P [kPa]

H [m] 50 45 40 35 30 25 20 15 10 5 0

400 300

JPBasic 2 JPBasic 3

100 80 60 40 20 0

TM02 9068 1704

200 100 0

B L

Electrical data Pump type JPBasic 2 PT JPBasic 3 PT JPBasic 4 PT Voltage [V] 1 x 220-240 1 x 220-240 1 x 220-240 P1 Max. [kW] 0.72 0.85 1.13 P1
[hp]

In
[A]

Capacitor [F] 12.5 12.5 16 [Vc] 450 450 450

10

20

30

40

50 Q [l/min]

0.44 0.6 0.75

3.12 3.8 5.1

Pump type JPBasic 2 PT JPBasic 3 PT JPBasic 4 PT

Dimensions [mm] A 550 550 550 A1 390 390 409 B 270 270 270 D 282 282 282 H 290 290 290 H1 232 232 232 L 332 332 332

DNA Rp 1 Rp 1 Rp 1

DNM Rp 1 Rp 1 Rp 1

Packing dimensions [mm] L/A 576 576 576 L/B 366 366 366 L/H 554 554 554

Vol [m3] 0.107 0.107 0.107

Weight [kg] 16.1 16.2 21.4

TM02 8940 1704

0.0 0.0

0.4

0.8 0.2

1.2

1.6 0.4

2.0 2.4 0.6

2.8 0.8

Q [m/h] Q [l/s]

11

JPBasic PS

General data

JPBasic PS
Auto pressure units Single-phase version: Self-priming centrifugal pump equipped with pressure gauge, pressure switch (PS), power supply cable with plug and three-way brass connector for connecting to a tank.

JPBasic-PS

Pump type JPBasic 2 PS JPBasic 3 PS JPBasic 4 PS JPBasic 5 PS

Voltage [V]

P1
Max. [kW]

Electrical data P2 P2 In
Max. [kW] [hp] [A]

Capacitor [F] 12.5 12.5 16 31.5 [Vc] 450 450 450 450

1 x 220-240 0.72 0.44 1 x 220-240 0.85 0.6 1 x 220-240 1.13 0.75 1 x 220-240 1.6 1.1

0.6 0.8 1.0 1.5

3.12 3.8 5.1 7.2

Gr7908

Pump type JPBasic 2 PS JPBasic 3 PS JPBasic 4 PS JPBasic 5 PS A 395 395 414 563 A1 390 390 390 556 B 282 282 282 217 C 108 108 108 160 D 196 196 196 109

Dimensions [mm] E 192 192 192 329 F 14 14 14 15 G 111 111 111 145 I 11 H 232 232 232 312 H1 199 199 199 279 H2 200 200 221 H3 144 144 144 159 I 9 9 9 -

DNA Rp 1 Rp 1 Rp 1 Rp 1

DNM Rp 1 Rp 1 Rp 1 Rp 1

Packing dimensions [mm] L/A L/B L/H 486 366 232 486 366 232 486 366 232 600 236 267

Vol [m3] 0.041 0.041 0.041 0.038

Weight [kg] 11.9 12.1 13.9 31.5

12

JPBasic PC

General data

JPBasic PC
Self-priming centrifugal pump equipped with presscontrol (PC) and power supply cable.

Applications
Automatic water lifting sets, particulary suitable for domestic use, small installations for civil, industrial and agricultural use, washing systems and hobbies. These are characterised by the use of JPBasic PC selfpriming centrifugal pumps which can operate even when there is air, gas and small quantities of sand in the water. They are indispensable for use in artesian wells and whereever suction difficulties arise.

Operation
The pump is equipped with a Presscontrol (PC) which controls, manages and commands it, regulating its operation, limiting the number of starts and guaranteeing maximum pressure stability inside the hydraulic circuit in which it is installed. The automatic devices is the result of a series of studies conducted to optimise the efficiency of the system while preserving the structural features and sturdiness of existent devices. Automatic sets differ from the traditional systems equipped with a pressure switch based on pump starting and stopping as they avoid sudden variations and drops in pressure. They are basically equipped with a double control device, as built-in electrical circuit gathers the data regarding pressure and water flow in the system and processes them to allow the pump to operate under optimum performance conditions. The automatic device is supplied pre-installed on the pump, requires no type of regulation and considerably reduces overall dimensions by totally eliminating the bulky tanks used traditional installations.

Gr7907

13

JPBasic PC

General data

Optimised management of the hydraulic installation and its components


1. Enables the system to operate only when there is water present; if, for any reason, no water reaches the system, it blocks the pump, so that it does not operate while dry. In this case the ALARM LED lights up. 2. Maintains pump operation when the appliances are opened by one or more users, in order to prevent sudden changes in pressure. When an appliance is opened the depression created in the system acts on the membrane which gradually releases a spring. The sensors detect the movement, send a signal to the electronic unit which enables pump start-up. 3. Automatically stops the pump when the users stop drawing water. When the appliances are closed, under the effect of the rise in pressure within the hydraulic system, the membrane totally compresses the spring. This new situation is analysed by the sensors which send the unit a signal to stop the pump. The stop is timed in order to prevent the pump from being subjected to repeated starts caused by users opening and closing the appliances within a few seconds of each other. Furthermore, if boilers are supplied, the continuous delivery of hot water is guaranteed by timing the stops. 4. Instant pump start when one of the appliances is opened even with a minimum amount of water drawn. 5. In the event of leaks in the system (drips or small trickles) the device limits the number of cycles, prolonging pump running time by about 10 seconds. 6. It eliminates water hammering by means of a specific shock absorber which absorbs the effect. 7. Manual reset in the event of a breakdown in the hydraulic circuit or of overload protector intervention; in this case, after eliminating the cause, press the "RESET" button positioned on the terminal board cover for a few seconds until the "ALARM" LED switches off. 8. In the event of a power cut, automatic reset as soon as the power is restored. 9. The system is self-protected against overheating. When there is an excess in temperature inside the motor windings, this operation is carried out automatically. It is also restored automatically once the temperature has dropped below the level which guarantees operation without damage to the system.

Constructional features of the pump


JPBasic 3 PC, JPBasic 4 PC: Cast iron pump body and motor support treated against corrosion also on the inner surface. Technopolymer impeller, diffuser and Venturi tube. Stainless steel pressure discs and rotor shaft. Carbon/ceramic mechanical seal.

Constructional features of the motor


Induction motor, closed and cooled with external ventilation. Rotor mounted on greased sealed-for-life ball bearings. Built-in thermal and current oyerload protection and a capacitor permanently in circuit. Manufactured according to standard EN 60335-2-41. Motor protection: Insulation class: IP 44 F.

All the pumps are supplied with 0.75 metres of power cable type H05 RN-F with plug.

Constructional features of the automatic control


The automatic device which regulates the pump operation is basically formed of the following components: FLOW SWITCH SET: this comprises a 4-way metal union with two housings for the delivery and pressure sensors. Both their seat and the sensor capsule are structured so that no pre-calibration is required. SPRING EXPANSION TANK: manufactured in pressed and flanged stainless steel, this has been designed to ensure maximum reliability and sturdiness with minimum overall dimensions. Inside it houses a spring which operates as a pressure switch. ELECTRONIC CARD: this is composed of a printed circuit which receives signals from the sensors and manages the automatic device as indicated in the paragraph regarding operation. The commands plate with the two LEDs, green = ON, red = Alarm and the Reset button for resetting the pump is positioned on the terminal board cover. CHECK DEVICE: all automatic sets are equipped with a check valve which has been selected to ensure maximum long lasting reliability. In order to prevent operational faults in the system it is essential that the position of the valve is not changed during assembly. The automatic control is supplied pre-assembled with all the accessories.

14

JPBasic PC

Technical data

Technical data
Operating range: Liquid quality requirements: Liquid temperature range: From 0.3 to 3.6 m3/h with head up to 51 metres Clean, free from solids or abrasive substances, non aggressive From 0C to +35C for domestic use (Safety regulations EN 60335-2-41) From 0C to +40C for other uses.

Maximum ambient temperature: +40C Maximum operating pressure: Installation: 6 bar (600 kPa) Fixed in a horizontal position.

JPBasic PC
C DNM

0 0

2 2

4 4

6 6

10 8

12 10

14 Q [US GPM] Q [IMP GPM] H [ft] 160 140 120

P [kPa]

H [m] 50 45 40 35 30 25 20 15 10 5 0

DNA

400 300

JPBasic 2 JPBasic 3 JPBasic 4

100 80 60 40 20 0

H3

TM02 9067 1704

200 100 0

F E A

I G B

Electrical data Pump type JPBasic 2 PC JPBasic 3 PC JPBasic 4 PC Voltage [V] 1 x 220-240 1 x 220-240 1 x 220-240 P1
Max. [kW]

10

20

30

40

50 Q [l/min]

P2
[kW]

P2
[hp]

In
[A]

Capacitor [F] 12.5 12.5 16 [Vc] 450 450 450

0.72 0.85 1.13

0.44 0.60 0.75

0.6 0.8 1.0

3.12 3.4 4.7

Pump type A JPBasic 2 PC JPBasic 3 PC JPBasic 4 PC 395 395 414 B 212 212 212 C 108 108 108

Dimensions [mm] E 192 192 197 F 14 14 14 G 111 111 111 I 9 9 9 H 375.5 375.5 375.5 H3 144 144 144

DNA Rp 1 Rp 1 Rp 1

DNM Rp 1 Rp 1 Rp 1

Packing dimensions [mm] L/A 524 524 524 L/B 248 248 248 L/H 309 309 309

Vol [m3] 0.04 0.04 0.04

Weight [kg] 14 16 16

TM02 8940 1704

0.0 0.0

0.4

0.8 0.2

1.2

1.6 0.4

2.0 2.4 0.6

2.8 0.8

Q [m/h] Q [l/s]

15

JDBasic

General data

JDBasic 2, JDBasic 4

JDBasic 5, JDBasic 7

Gr7899General data

Applications
Self-priming centrifugal pump for suction up to 27 metres, reached by means of an ejector to be inserted in wells with a diameter of 4" or over. For use in supplying water to farmhouses and in small-scale agriculture.

Motor Asynchronous motor, closed and cooled with external ventilation. Rotor mounted on greased sealed-for-life ball bearings, selected to ensure silent running and a long life. Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phase version. For the protection of the three-phase motor it is advisable to use a suitable overload protection complying with the regulations in force. Manufactured according to standard EN 60335-2-41. Motor protection: Terminal box protection: Insulation class: Standard voltage: IP 44 IP 55 F 1 x 220-240 V, 50 Hz 3 x 220-240/380-415 V, 50 Hz.

Constructional features
Pump Cast iron pump body and motor support treated against corrosion also on the inner surface. Technopolymer impeller, diffuser and Venturi tupe and brass nozzle. Stainless steel pressure disc. Carbon/ceramic mechanical seal mounted on stainless steel rotor shaft extension. Ejector: Cast iron body with anti-corrosive treatment also on the inner surface. Technopolymer Venturi tube and brass nozzle. The ejector is available in 3 models (E20 - E25 - E30) to be chosen according to performance requirements. (see tables on pages 17 and 18).

Material specification
Pos. 1 2 3 4 6 Description Pump body Ejector body Support Impeller Diffuser Material Cast iron EN-GJL-200 Cast iron EN-GJL-200 Cast iron EN-GJL-200 Noryl GFN 2 Noryl GFN 2 (JDBasic 2-4) Stainless steel AISI 416 X 12 Cr S 13
9 16 4 7
TM02 8456 0204

1 6 28

Shaft with rotor

(JDBasic 5-7) AISI 303 X10 Cr NiS 18 9 8 9 16 28 Venturi Nozzle Mechanical seal O-ring gasket Noryl GFN 2 Brass Carbon/Ceramic NBR

16

TM00 9974 1097

JDBasic

Technical data

Technical data
Operating range: Liquid quality requirements: Liquid temperature range: Up to 4.3 m3/h Clean, free from solids or abrasive substances, non aggressive From 0C to +35C for domestic use

Maximum ambient temperature: + 40C Maximum operating pressure: Installation: Special executions on request: JDBasic 2, JDBasic 4: 6 bar (600 kPa) JDBasic 5, JDBasic 7: 8 bar (800 kPa) Fixed in a horizontal position Other voltages and/or frequencies.

JDBasic 2, JDBasic 4
Hydraulic data (n 2850 min -1) Delivery pressure in bar
Z A

Pump Ejector Suction type type depth 9


V

1.5 1813 1426 900 1753 1345 1166 2386 1930 1459 / / / /

2.0 1080 720 326 1286 965 761 1756 1190 773 1240 1028 785 635

2.5 446 225 / 812 608 452 1097 536 252 872 701 527 374

3.0 33 / / 524 356 228 515 87 / 566 449 302 180

3.5 / / / 261 162 45 126 / / 329 255 150 39

4.0 / / / 46 0 / / / / 156 96 15 /

Capacity table in [l/h] E25 12 15 9 E30 12 15


TM02 8455 0204

H1

G B

JDBasic 2

H2

9 E25 JDBasic 4 12 15 12 E30 15 18 21

Pump type

H1 H2

DNA G1 G1

DNM G1 G1

DNE G1 G1

A H H1 [mm] [mm] [mm] 97 97 295 295 243 243

x G1 G1

y G1 G1

z G1 G1

Vol L/A L/B L/H [m3] [mm] [mm] [mm] 452 492 218 224 257 277

JDBasic 2 365 180 90 202 140 9,5 225 47 92 JDBasic 4 385 180 90 202 140 9,5 225 47 92

0.025 13.9 0.025 16.6

Electrical data Pump type Voltage [V] 1 x 220-240 JDBasic 2 3 x 220-240/ 380-415 P1
Max. [kW]

Electrical data In
[A]

P2
[kW]

P2
[hp]

Capacitor [F] 14 [Vc] 450 -

Pump type

Voltage [V] 1 x 220-240

P1
Max. [kW]

P2
[kW]

P2
[hp]

In
[A]

Capacitor [F] 16 [Vc] 450 -

0.69 0.66

0.44 0.44

0.6 0.6

3.2 2.6/1.5

0.79 0.64

0.75 0.75

1 1

3.8 2.6/1.5

JDBasic 4

3 x 220-240/ 380-415

Weight [kg]

Dimensions [mm]

Ejector

Packing dimensions

TM00 9976 1097

17

JDBasic

Technical data

JDBasic 5, JDBasic 7
Hydraulic data (n 2850 min -1)
A C B DNM

Pump Ejector Suction 3.0 type type depth 9

Delivery pressure [bar] 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 Capaticy table [l/h] / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /

3412 2769 2090 1363 586 3065 2400 1719 952 143 2643 2000 1257 495 2289 1593 826 0 / /

E 20 JDBasic 5

12 15 18 15

2745 2244 1761 1257 814 435 77 2465 1969 1477 997 584 218 / 2206 1712 1224 779 388 45 /

I E G

E 25

18 21 21

1797 1615 1368 1106 861 658 472 312 163 25 / 1652 1484 1217 962 740 547 378 220 67 1520 1333 1069 841 636 448 287 139 / / / / / / / / / / / / 3431 2751 2033 1236 448 / 3043 2324 1554 763 2665 1936 1145 344 2244 1478 675 / 0 / / / / / / / / / / / / / / / /

E 30
Z C A

24 27 9 12 15 18 15

E 20

JDBasic 7

V H

2840 2324 1806 1296 849 463 138 / 2535 2038 1523 1049 640286 / 2267 1757 1257 817 424 91 / 1970 1458 989 583 226 / /

TM02 8457 0204

E 25

18 21 24 21

H1

X E

1812 1671 1419 1163 919 716 531 377 226 91 1668 1549 1278 1023 791 619 445 297 156 13 1541 1395 1145 906 700 521 351 206 62 /

E 30

24 27

Pump type JDBasic 5 JDBasic 7

H1 H2

DNA G1 G1

DNM DNE G1 G1 G1 G1

A H H1 [mm] [mm] [mm] 97 97 295 295 243 243

L/A 427 522

L/B 246 246

L/H 307 307

Vol [m3] 0.032 0.039

388 210 50 197 145 11 255 53 108 462 210 50 197 145 11 255 53 108

G1 G1 G1 G1 G1 G1

Electrical data Pump type JDBasic 5 JDBasic 7 Voltage [V] 1 x 220-240 1 x 220-240 P1
Max. [kW]

Electrical data In
[A]

P2
[kW]

P2
[hp]

Capacitor [F] 31.5 40 [Vc] 450 450

Pump type

Voltage [V]

P1 Max. [kW] 1.45 1.78

P2
[kW]

P2
[hp]

In
[A]

1.56 2.1

1.1 1.85

1.5 2.5

7 8.3

JDBasic 5 3 x 220-240/380-415 JDBasic 7 3 x 220-240/380-415

1.1 1.85

1.5 2.5

4.7/2.7 5.6/3.2

Instructions for conversion


Conversion from JDBasic 5, JDBasic 7 to JPBasic 5, JPBasic 7
Screw the nozzle (9) into the seat in the ejector body (2) and the Venturi tube (8). Position the O-rings (27) and (29) in their respective seats and fix the ejector body (2) onto the pump body (1) with the two screws (53).

TM00 9980 1097 & TM00 9981 1097

Conversion from JPBasic 5, JPBasic 7 to JDBasic 5, JDBasic 7


Slacken and remove the two joining screws (53) between the ejector body (2) and the pump body (1). Collect the O-rings (27) and (29).

18

Weight [kg] 31 35

Dimensions [mm]

Ejector

Packing dimensions [mm]

CHBasic

CHBasic

Performance range
p

[kPa]
600

H [m]
60

CHBasic
50 Hz
3

55

500

50

4
45

400

40

35

300

30

25

200

20

15

100

10

0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5

Q [m/h]
TM02 8933 1804

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

Q [l/s]

19

CHBasic

General data

CHBasic 2, CHBasic 3, CHBasic 4


6 3

Applications
Multistage horizontal centrifugal pump, featuring extremely silent running suitable for domestic use for water supply and pressurisation, irrigation of gardens and vegetable gardens, and moving water in general.

Gr7896

16 28

Material specification
Pos. 1 3 4 6 7 16 28 Description Pump body Support Impeller Diffuser Shaft Mechanical seal O-ring gasket Material Cast iron EN-GJL-200 Cast iron EN-GJL-200 Noryl GFN 2 Noryl GFN 2 Stainless steel AISI 303 X10 CrNiS 18 9 Carbon/Ceramic NBR

Constructional features
Pump Pump body in cast iron. Motor support in die-cast aluminium, seal holder in stainless steel. Mechanical seal in carbon/ceramic. Shaft in stainless steel. Rotors, diffuser bodies and diffusers in technopolymer. Adjustment rings in stainless steel. Motor Continuous service asynchronous motor (2 poles) cooled by external fan. Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phase version. The user is responsible for protection in the three-phase version. Motor protection: IP 44 Terminal box protection: IP 55 Insulation class: F Standard voltage: 1 x 220-240 V, 50 Hz 3 x 220-240/380-415 V, 50 Hz.

20

TM02 9065 3204

CHBasic

Technical data

Technical data
Operating range: Liquid quality requirements: Liquid temperature range: From 0.6 to 10.5 m3/h with head up to 63 metres Clean, free from solids or abrasive substances, non aggressive, chemically neutral and close to the characteristics of water. From 0C to +35C for domestic use (Safety regulations EN 60335-2-41) From 0C to +40C for other uses.

Maximum ambient temperature: +40C Maximum suction depth: Maximum operating pressure: Installation: Special executions on request: 8 metres (800 kPa) CHBasic 2, CHBasic 3, CHBasic 4: Fixed in a horizontal position Other voltages and/or frequencies. 6 bar (600 kPa)

Curve conditions
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A.

21

CHBasic

Technical data

CHBasic 2
0 2 2 4 4 6 6 8 10 8 12 10 14 12 16 14 18 Q [US GPM] 16 Q [IMP GPM] H [ft] 160 140 120 100 80 60 40 20 0

A C DNM
P [kPa] H [m] 50 45 40 35 300 30 25 200 100 0 20 15 10 5 0 0.0 0.0 0.5 1.0 0.2 1.5 0.4 2.0 2.5 3.0 0.6 0.8 3.5 4.0 Q [m/h] 1.0 1.2 Q [l/s] 0

H1 DNA

H2

400

G B

TM02 9062 1704

Electrical data Pump type Voltage [V] 1x220-240 3x220-240/380-415 P1 Max. [kW] 0.7 P2
[kW]

P2
[hp]

In
[A]

Capacitor [F] [Vc] 10 450 0 10 20 30 40 50 60 70Q [l/min]

CHBasic 2

0.72 0.45 0.6

3.2

0.45 0.6 2.2/1.3

Pump type CHBasic 2

Dimensions [mm] A 406 B 175 C 122 E 207 F 13.5 G 111 I 9 H 200 H1 179 H2 143.5 DNA Rp 1 DNM Rp 1

Packing dimensions [mm] L/A 480 L/B 212 L/H 265

Vol [m3] 0.027

Weight [kg] 12.5

CHBasic 3
0 2 2 4 4 6 6 8 10 8 12 10 14 16 18 20 22 24 12 14 16 18 20 Q [US GPM] Q [IMP GPM] H [ft] 160 140 120 100 80 60 40 20 0

A C DNM
P [kPa] 500 H 0 [m] 55 50 45 400 300 200 100 0 40 35 30 25 20 15 10 5 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5Q [m/h] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 Q [l/s]

H1 DNA

H2

G B

TM02 9062 1704

Electrical data Pump type Voltage [V] 1x220-240 3x220-240/380-415 P1 Max. [kW] 1.2 1.2 P2
[kW]

P2
[hp]

In
[A]

Capacitor [F] [Vc] 20 450 0 10 20 30 40 50 60 70 80 90 Q [l/min]

CHBasic 3

0.75 0.75

1 1

5.3 3.8/2.2

Pump type CHBasic 3

Dimensions [mm] A 425 B 175 C 122 E 207 F 13.5 G 111 I 9 H 213 H1 179 H2 143.5 DNA Rp 1 DNM Rp 1

Packing dimensions [mm] L/A 480 L/B 212 L/H 265

Vol [m3] 0.027

Weight [kg] 15.4

22

TM02 9010 1304

TM02 9009 1304

CHBasic

Technical data

CHBasic 4
0 4 4 8 8 12 12 16 20 16 24 20 28 24 32 28 Q [US GPM] Q [IMP GPM] H [ft] 160 140 120 100 80 60 40 20 0 0.4 1.2

A C DNM
P [kPa] H [m] 50 45 40 35 300 30 25 200 100 0 20 15 10 5 0 0 0.0 1 2 3 0.8 4 5 6 1.6 7 2.0 Q [m/h] Q [l/s] 0

H1 DNA

H2

400

G B

TM02 9062 1704

Electrical data Pump type Voltage [V] 1x220-240 3x220-240/380-415 P1 Max. [kW] 1.2 1.2 P2 0.8 0.8 P2 1.1 In
[A]

Capacitor [F] [Vc] 20 450 0 20 40 60 80 100 120 Q [l/min]

[kW] [hp]

CHBasic 4

5.3

1.1 3.8/2.2

Pump type A CHBasic 4 425 A1 175 B 122 C 207 E

Dimensions [mm] F 111 G 9 H 213 H3 179 I 143.5 DNA Rp 1 DNM Rp 1

Packing dimensions [mm] L/A 480 L/B 212 L/H 265

Vol [m3] 0.027

Weight [kg] 15.4

13.5

TM02 9011 1304

23

CHBasic PT

General data

CHBasic PT
6 3

16 28

Applications
Multistage horizontal centrifugal pump, featuring extremely silent running suitable for domestic use for water supply and pressurisation, irrigation of gardens and vegetable gardens, and moving water in general. The set is composed of a diaphragm tank with capacity 19 litres, pressure switch for automatic operation, pressure gauge, JPBasic electric pump complete with power cable and plug, kit for coupling the pump and the tank, all assembled and ready for installation. Note: Vertical 8 litres or 18 litres tanks are used in some markets.

Material specification
Pos. 1 3 4 6 7 16 28 Description Pump body Support Impeller Diffuser Shaft Mechanical seal O-ring gasket Material Cast iron EN-GJL-200 Cast iron EN-GJL-200 Noryl GFN 2 Noryl GFN 2 AISI 303 stainless steel X 10 Cr NiS 18 9 Carbon/Ceramic NBR

Constructional features
Pump Pump body in cast iron. Motor support in die-cast aluminium, seal holder in stainless steel. Mechanical seal in carbon/ceramic. Shaft in stainless steel. Rotors, diffuser bodies and diffusers in technopolymer. Adjustment rings in stainless steel. Motor Continuous service asynchronous motor (2 poles) cooled by external fan. Built-in thermal and current overload protection and a capacitor permanently in circuit. Motor protection: Terminal box protection: Insulation class: Standard voltage: Tank Horizontal type, capacity 19 litres, with butyl diaphragm, complete with feet on the bottom and brackets for fixing the pump on top IP 44 IP 55 F 1 x 220-240 V, 50 Hz.

24

TM02 9065 3204

TM02 9061 1704

CHBasic PT

Technical data

Technical data
Operating range: Liquid quality requirements: Liquid temperature range: From 0.6 to 10.5 m3/h with head up to 63 metres Clean, free from solids or abrasive substances, non aggressive From 0C to +35C for domestic use (Safety regulations EN 60335-2-41) From 0C to +40C for other uses.

Maximum ambient temperature: +40C Maximum suction depth: Maximum operating pressure: Installation: Special executions on request: 8 metres (800 kPa) CHBasic 2 PT, CHBasic 3 PT, CHBasic 4 PT: 6 bar (600 kPa) Fixed in a horizontal position Other voltages and/or frequencies.

Curve conditions
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A.

CHBasic 2 PT
A1 D
0 H 0 [m] 55 50 45 400 40 35 30 25 200 100 0 20 15 10 5 0 0 0.0 1 0.4 2 3 0.8 4 1.2 5 6 1.6 7 2.0 Q [m/h] Q [l/s]
CHBasic 2 CHBasic 3 CHBasic 4

4 4

8 8

12 12

16

20 16

24 20

28 24

32 28

Q [US GPM] Q [IMP GPM] H [ft] 160 140 120 100 80 60 40 20 0

H1

P [kPa] 500

TM02 9066 1704

300

Electrical data Pump type CHBasic 2 PT CHBasic 3 PT CHBasic 4 PT 1 x 220-240 Voltage [V] P1
Max. [kW]

P2
[kW]

P2
[hp]

In
[A]

Capacitor [F] 12.5 12.5 16 [Vc] 450 450 450

20

40

60

80

100

120 Q [l/min]

0.72 1.2 1.2

0.45 0.75 0.80

0.60 1.0 1.1

3.2 5.3 5.3

Pump type A CHBasic 2 PT CHBasic 3 PT CHBasic 4 PT 550 550 550 A1 405 425 425 B 270 270 270 D

Dimensions [mm] H 290 290 290 H1 200 200 200 L 330 330 330 DNA Rp 1 Rp 1 Rp 1 DNM Rp 1 Rp 1 Rp 1

Packing dimensions [mm] L/A 576 576 576 L/B 366 366 366 L/H 554 554 554

Vol [m3] 0.107 0.107 0.107

Weight [kg] 17.7 20.6 20.6

281 281 281

TM02 8939 1704

25

CHBasic PS

General data

CHBasic PS
6 3

Applications
Multistage horizontal centrifugal pump, featuring extremely silent running suitable for domestic use for water supply and pressurisation, irrigation of gardens and vegetable gardens, and moving water in general.

Gr7918

16 28

Material specification
Pos. 1 3 4 6 7 16 28 Description Pump body Support Impeller Diffuser Shaft Mechanical seal O-ring gasket Material Cast iron EN-GJL-200 Cast iron EN-GJL-200 Noryl GFN 2 Noryl GFN 2 AISI 303 stainless steel X 10 Cr NiS 18 9 Carbon/Ceramic NBR

Constructional features
Pump Pump body in cast iron. Motor support in die-cast aluminium, seal holder in stainless steel. Mechanical seal in carbon/ceramic. Shaft in stainless steel. Rotors, diffuser bodies and diffusers in technopolymer. Adjustment rings in stainless steel. Motor Continuous service asynchronous motor (2 poles) cooled by external fan. Built-in thermal and current overload protection and a capacitor permanently in circuit. Motor protection: Terminal box protection: Insulation class: Standard voltage: IP 44 IP 55 F 1 x 220-240 V, 50 Hz.

26

TM02 9065 3204

CHBasic PS

Technical data

Technical data
Operating range: Liquid quality requirements: Liquid temperature range: From 0.6 to 10.5 m3/h with head up to 63 metres Clean, free from solids or abrasive substances, non aggressive From 0C to +35C for domestic use (Safety regulations EN 60335-2-41) From 0C to +40C for other uses.

Maximum ambient temperature: +40C Maximum suction depth: Maximum operating pressure: Installation: Special executions on request: 8 metres (800 kPa) CHBasic 2 PS, CHBasic 3 PS, CHBasic 4 PS: 6 bar (600 kPa) Fixed in a horizontal position Other voltages and/or frequencies.

Curve conditions
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A.

CHBasic PS
0
A C DNM D DNM

4 4

8 8

12 12

16

20 16

24 20

28 24

32 28

Q [US GPM] Q [IMP GPM] H [ft] 160 140 120 100 80 60 40 20

P [kPa] 500

H 0 [m] 55 50 45 40 35 30 25 20 15 10 5

H1 H3 DNA

H2

400 300 200 100 0

G B

TM02 9064 1704

CHBasic 2

CHBasic 3

CHBasic 4

0 0 0.0 1 0.4 2 3 0.8 4 1.2 5 6 1.6 7 2.0 Q [m/h] Q [l/s]

Electrical data Pump type CHBasic 2 PS CHBasic 3 PS CHBasic 4 PS 1 x 220-240 Voltage [V] P1
Max. [kW]

P2
[kW]

P2
[hp]

In
[A]

Capacitor [F] 10 20 20 [Vc] 450 450 450


0 20 40 60 80 100 120 Q [l/min]

1.75 1.20 1.20

0.45 0.75 0.80

0.60 1.00 1.10

3.2 5.3 5.3

Pump type A CHBasic 2 PS CHBasic 3 PS CHBasic 4 PS 405 425 425 B 281 281 281 C 122 122 122 D 196 196 196 E 205 205 205 F 14 14 14

Dimensions [mm] G 111 111 111 H 238 238 238 H1 205 205 205 H2 200 200 200 H3 144 144 144 I 9 9 9 DNA Rp 1 Rp 1 Rp 1 DNM Rp 1 Rp 1 Rp 1

Packing dimensions [mm] L/A 449 449 449 L/B 309 309 309 L/H 244 244 244

Vol [m3] 0.03 0.031 0.03

Weight [kg] 14 17 17

TM02 8939 1704

27

CHBasic PC

General data

CHBasic PC

the membrane which gradually releases a spring. The sensors detect the movement, send a signal to the electronic unit which enables pump start-up. 3. Automatically stops the pump when the users stop drawing water. When the appliances are closed, under the effect of the rise in pressure within the hydraulic system, the membrane totally compresses the spring. This new situation is analysed by the sensors which send the unit a signal to stop the pump. The stop is timed in order to prevent the pump from being subjected to repeated starts caused by users opening and closing the appliances within a few seconds of each other. Furthermore, if boilers are supplied, the continuous delivery of hot water is guaranteed by timing the stops. 4. Instant pump start when one of the appliances is opened even with a minimum amount of water drawn. 5. In the event of leaks in the system (drips or small trickles) the device limits the number of cycles, prolonging pump running time by about 10 seconds. 6. It eliminates water hammering by means of a specific shock absorber which absorbs the effect. 7. Manual reset in the event of a breakdown in the hydraulic circuit or of overload protector intervention; in this case, after eliminating the cause, press the "RESET" button positioned on the terminal board cover for a few seconds until the "ALARM" LED switches off. 8. In the event of a power cut, automatic reset as soon as the power is restored. 9. The system is self-protected against overheating. When there is an excess in temperature inside the motor windings, this operation is carried out automatically. It is also restored automatically once the temperature has dropped below the level which guarantees operation without damage to the system.
Gr7916

Applications
Multistage horizontal centrifugal pump, featuring extremely silent running suitable for domestic use for water supply and pressurisation, irrigation of gardens and vegetable gardens, and moving water in general.

Operation
The pump is equipped with a Presscontrol (PC) which controls, manages and commands it, regulating its operation, limiting the number of starts and guaranteeing maximum pressure stability inside the hydraulic circuit in which it is installed. The automatic devices is the result of a series of studies conducted to optimise the efficiency of the system while preserving the structural features and sturdiness of existent devices. Automatic sets differ from the traditional systems equipped with a pressure switch based on pump starting and stopping as they avoid sudden variations and drops in pressure. They are basically equipped with a double control device, as built-in electrical circuit gathers the data regarding pressure and water flow in the system and processes them to allow the pump to operate under optimum performance conditions. The automatic device is supplied pre-installed on the pump, requires no type of regulation and considerably reduces overall dimensions by totally eliminating the bulky tanks used traditional installations.

Constructional features
Pump Pump body in cast iron. Motor support in die-cast aluminium, seal holder in AISI 304 steel. Mechanical seal in carbon/ceramic. Rotor shaft in AISI 304 steel. Rotors, diffuser bodies and diffusers in technopolymer. Adjustment rings in stainless steel. Motor Continuous service asynchronous motor (2 poles) cooled by external fan. Built-in thermal and current overload protection and a capacitor permanently in circuit. Motor protection: Terminal box protection: Insulation class: Standard voltage: IP 44 IP 55 F 1 x 220-240 V, 50 Hz.

Optimised management of the hydraulic installation and its components


1. Enables the system to operate only when there is water present; if, for any reason, no water reaches the system, it blocks the pump, so that it does not operate while dry. In this case the ALARM LED lights up. 2. Maintains pump operation when the appliances are opened by one or more users, in order to prevent sudden changes in pressure. When an appliance is opened the depression created in the system acts on

28

CHBasic PC

Technical data

16 28

Material specification
Pos. 1 3 4 6 7 16 28 Description Pump body Support Impeller Diffuser Shaft Mechanical seal O-ring gasket Material Cast iron EN-GJL-200 Cast iron EN-GJL-200 Noryl GFN 2 Noryl GFN 2 AISI 303 stainless steel X 10 Cr NiS 18 9 Carbon/Ceramic NBR

TM02 9065 3204

29

CHBasic PC

Technical data

Technical data
Operating range: Liquid quality requirements: Liquid temperature range: From 0.6 to 10.5 m3/h with head up to 63 metres Clean, free from solids or abrasive substances, non aggressive From 0C to +35C for domestic use (Safety regulations EN 60335-2-41) From 0C to +40C for other uses.

Maximum ambient temperature: +40C Maximum suction depth: Maximum operating pressure: Installation: Special executions on request: 8 metres (800 kPa) CHBasic 2 PC, CHBasic 3 PC, CHBasic 4 PC: 6 bar (600 kPa) Fixed in a horizontal position Other voltages and/or frequencies.

Curve conditions
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A.

CHBasic PC
C DMN
0 H 0 [m] 55 50 45 400 300 200 100 0 40 35 30 25 20 15 10 5 0 0 0.0 1 0.4 2 3 0.8 4 1.2 5 6 1.6 7 2.0 Q [m/h] Q [l/s]
CHBasic 2 CHBasic 3 CHBasic 4

4 4

8 8

12 12

16

20 16

24 20

28 24

32 28

Q [US GPM] Q [IMP GPM] H [ft] 160 140 120 100 80 60 40 20 0

P [kPa]

DNA

500

F E A

I G B

TM02 9063 1704

Electrical data Pump type CHBasic 2 PC CHBasic 3 PC CHBasic 4 PC 1 x 220-240 Voltage [V] P1
Max. [kW]

P2
[kW]

P2
[hp]

In
[A]

Capacitor [F] 10 20 20 [Vc] 450 450 450

20

40

60

80

100

120 Q [l/min]

0.72 1.2 1.2

0.45 0.75 0.80

0.6 1.0 1.1

3.2 5.3 5.3

Pump type A CHBasic 2 PC CHBasic 3 PC CHBasic 4 PC 406 425 425 B 212 212 212 C 122 122 122 E 207 207 207

Dimensions [mm] F 13.5 13.5 13.5 G 111 111 111 H 376 376 376 I 9 9 9 DNA Rp 1 Rp 1 Rp 1 DNM Rp 1 Rp 1 Rp 1

Packing dimensions [mm] L/A 524 524 524 L/B 248 248 248 L/H 309 309 309

Vol [m3] 0.04 0.04 0.04

Weight [kg] 14 16 16

30

TM02 8939 1704

NSBasic

NSBasic Single impeller

Performance range
p [kPa]
700

H [m]
70 65

NSBasic
50 Hz
5-60

600

60 55

500

50 45

5-50

6-40 3-40

400

40 6-30 35 5-33

300

30 25 4-23

200

20 15

13-18

100

10 5

0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Q [m/h]

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

Q [l/s]

TM02 8934 1804

31

NSBasic

General data

NSBasic single impeller pumps


1 4 28 3

Gr7897

16 7

Applications
Single impeller centrifugal pump designed for lifting water in domestic, civil, industrial and agricultural installations and for decanting, mixing and irrigating uses.

Material specification
Description 1 3 4 7 Pump body Support Impeller Shaft Material Cast iron EN-GJL-200 Cast iron EN-GJL-200 Noryl GFN 2 X 12 CrNi 1810 X 10 CrNi 1809 NBR NSBasic 4-23 - NSBasic 13-18 NSBasic 5-33 Pump types

Constructional features
Pump Cast iron pump body and motor support treated against corrosion also on the inner surface. Technopolymer and cast iron impeller. Carbon/ceramic mechanical seal mounted on stainless steel rotor shaft extension. Motor Induction motor, closed and cooled with external fan. Rotor mounted on oversized greased sealed-for-life ball bearing to ensure silent running and long life. Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phase version. The user is responsible for the protection in the three-phase version. Manufactured according to standard EN 60335-2-41. Motor protection: Terminal box protection: Insulation class: Standard voltage: IP 44 IP 55 for the single-phase version F 1x220-240 V, 50 Hz 3x220-240/380-415 V, 50 Hz.

16 Mechanical seal Carbon/Ceramic 28 O-Ring Gasket

32

TM02 9070 1704

NSBasic

Technical data

Technical data
Operating range: Liquid quality requirements: Liquid temperature range: Maximum ambient temperature: Maximum operating pressure: Installation: Special versions on request: From 1.8 to 16.8 m3/h with head up to 34 metres Clean, free from solids or abrasive substances, non viscous, non aggressive, noncrystallized, chemically neutral, close to the characteristics of water. NSBasic 4-23, NSBasic 5-33, NSBasic 13-18: +40C NSBasic 4-23, NSBasic 5-33, NSBasic 13-18: 6 bar (600 kPa) from -10C to + 50C

Fixed in a horizontal or vertical position, as long as the motor is above the pump Other voltages and/or frequencies.

The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A.

NSBasic 4-23

12

16

20

24

Q [US GPM]

0 P [kPa] H [m] 20

12

16

20

Q [IMP GPM] H [ft] 60 40 20 0

TM02 9089 1804Single impeller

160 80 0 P2 [hp] 0.4 0.2 0.0

15 10 5 0 P2 [kW] 0.4 0.2 0.0


Eta

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5

Q [m/h]

P2

Eta [%] 40 20 0

Electrical data Pump type NSBasic 4-23 Voltage [V] 1x220-240 P1 P2 P2 Max. [kW] [kW] [hp] 0.65 0.37 0.5 In [A] 3.0 Capacitor [F] [Vc] 10 450 0 10 20 30 40 50 60 70 80 90 Q [l/min]

NSBasic 4-23 3x220-240/380-415 0.64 0.37

0.5 2.3/1.3

Pump type NSBasic 4-23

Dimensions [mm] A 275 B 160 C 50 D 100 E 50 F 15 G 110 I 9 H 205 H1 85 H2 120

DNA Rp 1

DNM Rp 1

Packing dimensions [mm] L/A 362 L/B 222 L/H 262

Vol [m3] 0.021

Weight [kg] 10.3

TM02 9012 1304

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [m/h] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 Q [l/s]

33

NSBasic

Technical data

NSBasic 5-33
0 4 8 12 16 20 24 28 32 36 Q [US GPM]

0 P [kPa] 320 240 160 80 0 20 10 0 P2 [kW] 0.8 0.4 0.0 0 0.0 0 H [m] 30

12

16

20

24

28

32 Q [IMP GPM] H [ft] 100 80 60 40 20 0

TM02 9089 1804

P2 [hp] 0.8 0.4 0.0

Q [m/h]

P2 Eta

Eta [%] 40 20 0

1 0.4

3 0.8

4 1.2

6 1.6

7 2.0

Q [m/h] 2.4 Q [l/s]

Pump type NSBasic 5-33

Voltage [V] 1x220-240

P1 P2 P2 Max. [kW] [kW] [hp] 1.3 1.2 0.75 0.75 1 1

In [A] 6.0 4.3/2.5

Capacitor [F] [Vc] 20 450 -

20

40

60

80

100

120

Q [l/min]

NSBasic 5-33 3x220-240/380-415

Pump type NSBasic 5-33

Dimensions [mm] A 300 B 185 C 50 D 108 E 58 F 15 G 140 I 9 H 235 H1 100 H2 135

DNA Rp 1

DNM Rp 1

Packing dimensions [mm] L/A 392 L/B 232 L/H 262

Vol [m3] 0.024

Weight [kg] 14.7

NSBasic 13-18
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 Q [US GPM]

0 P [kPa] 160 80 0 H [m] 20 15 10 5 0 P2 [kW] 0.8 0.4 0.0 0 0.0 0

10 15 20 25 30 35 40 45 50 55 60

Q [IMP GPM] H [ft] 60 40 20 0

TM02 9089 1804

P2 [hp] 0.8 0.4 0.0

10

12

14

16

Q [m/h]

P2 Eta

Eta [%] 40 20 0

2 0.5

4 1.0

6 1.5 2.0

10 12 14 2.5 3.0 3.5 4.0

16 4.5

Q [m/h] Q [l/s]

Electrical data Pump type NSBasic 13-18 Voltage [V] 1x220-240 P1 P2 P2 Max. [kW] [kW] [hp] 1.1 1.1 0.75 0.75 1 1 In [A] 4.6 3.6/2.1 Capacitor [F] [Vc] 20 450 0 40 80 120 160 200 240 Q [l/min]

NSBasic 13-18 3x220-240/380-415

Pump type NSBasic 13-18

Dimensions [mm] A 312 B 169 C 45 D 114 E 69 F 15 G 110 I 9 H 210 H1 210 H2 125

DNA Rp 1

DNM Rp 1

Packing dimensions [mm] L/A 392 L/B 232 L/H 262

Vol [m 3] 0.024

Weight [kg] 14

34

TM02 9014 1304

TM02 9013 1304

Electrical data

NSBasic

General data

NSBasic twin impeller pumps


34 3

4 28

16

Applications
Muliti-stage centrifugal pump with opposed twin impellers. Designed for use in pressurisation units for water supply systems and for supplying pressurised tanks. Suitable also for sprinkling, irrigation and other water supply application.

Material specification
Description 1 3 Pump body Support Material Cast iron EN-GJL-200 Cast iron EN-GJL-200 Noryl GFN 2 Ultem 2300 NSBasic 3-40 - NSBasic 5-50 NSBasic 6-30 - NSBasic 6-40 NSBasic 5-60 Pump types

Impeller

Constructional features
Pump Cast iron pump body and motor support treated against corrosion also on the inner surface. Technopolymer and cast iron impeller. Carbon/ceramic mechanical seal mounted on stainless steel rotor shaft extension. Motor Induction motor, closed and cooled with external fan. Rotor mounted on oversized greased sealed-for-life ball bearing to ensure silent running and long life. Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phase version. The user is responsible for the protection in the three-phase version. Manufactured according to standard EN 60335-2-41. Motor protection: Terminal box protection: IP 44 IP 55 for the single-phase version up to and including 0.75 kW F 1x220-240 V, 50 Hz 3x220-240/380-415 V, 50 Hz.

Shaft

Stainless steel ANSI X12 CrNi 1810 Carbon/Ceramic Impregnated Cellulose Cast iron EN-GJL-200

16 Mechanical seal 28 O-ring gasket 34 Intermediate Disc

Insulation class: Standard voltage:

TM02 9069 1704

Gr7928

35

NSBasic

Technical data

Technical data
Operating range: Liquid quality requirements: Liquid temperature range: Maximum ambient temperature: Maximum operating pressure: Installation: Special versions on request: From 1.5 to 10.8 m3/h with head up to 60 metres. clean, free from solids or abrasive substances, non viscous, non aggressive, non crystallized, chemically neutral, close to the characteristics of water. NSBasic 3-40, NSBasic 5-50, NSBasic 6-30, NSBasic 6-40: from 10C to + 50C NSBasic 5-60: from 15C to + 110C +40C NSBasic 3-40, NSBasic 5-50, NSBasic 6-30, NSBasic 6-40: 6 bar ( 600 kPa) NSBasic 5-50, NSBasic 5-60: 8 bar ( 800 kPa) Fixed in a horizontal or vertical position, as long as the motor is above the pump. Other voltages and/or frequencies.

The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A.

NSBasic 3-40
0 4 8 12 16 20 24 Q [US GPM]

0 P [kPa] 400 300 H [m] 40 30 20 10 0 P2 [kW] 0.8 0.4 0.0

12

16

20

Q [IMP GPM] H [ft] 120 80 40 0

TM02 9088 1804Twin impeller

200 100 0 P2 [hp] 0.8 0.4 0.0

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5

Q [m/h]

P2 Eta

Eta [%] 40 20 0

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [m/h] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 Q [l/s]

Pump type NSBasic 3-40

Voltage [V] 1x220-240

P1 P2 P2 Max. [kW] [kW] [hp] 1.2 1.2 0.75 0.75 1 1

In [A] 5.5 3.8/2.2

Capacitor [F] [Vc] 20 450 -

10

20

30

40

50

60

70

80

90

Q [l/min]

NSBasic 3-40 3x220-240/380-415

Pump type NSBasic 3-40

Dimensions [mm] A 342 B 180 C 76 D 148 E 72 F 15 G 148 I 9.5 H 235 H1 100 H2 135

DNA Rp 1

DNM Rp 1

Packing dimensions [mm] L/A 392 L/B 232 L/H 262

Vol [m3] 0.024

Weight [kg] 16.1

36

TM02 9015 1304

Electrical data

NSBasic

Technical data

NSBasic 5-50
0 4 8 12 16 20 24 28 32 Q [US GPM]

0 P [kPa] 400 300 200 100 0 P2 [hp] 1.6 0.8 0.0 H [m] 50 40 30 20 10 0 P2 [kW] 1.6 0.8 0.0 0

12

16

20

24

28

Q [IMP GPM] H [ft] 160 120 80 40 0

TM002 9088 1804

Q [m/h]

Eta [%] 40 20

P2 Eta

0 5 1.4 6 7 1.6 1.8 2.0 Q [m/h] 2.2 Q [l/s]

0 1 2 3 4 0.0 0.2 0.4 0.6 0.8 1.0 1.2

Pump type NSBasic 5-50

Voltage [V] 1x220-240

P1 P2 P2 Max. [kW] [kW] [hp] 1.9 2.0 1.1 1.1 1.5

In [A] 8.3

Capacitor [F] [Vc] 31.5 450 -

10 20 30 40 50 60 70 80 90 100 110 120 Q [l/min]

NSBasic 5-50 3x220-240/380-415

1.5 6.0/3.5

Pump type NSBasic 5-50 NSBasic 5-50

Phase A 1 3 370 370 B 210 210 C 75 75 D 144 144

Dimensions [mm] E 69 69 F 15 15 G 165 165 I 11.5 11.5 H 268 268 H1 118 118 H2 150 150

DNA Rp 1 Rp 1

DNM Rp 1 Rp 1

Packing dimensions [mm] L/A 415 415 L/B 235 234 L/H 295 295

Vol [m3] 0.029 0.029

Weight [kg] 23.3 23.8

NSBasic 5-60
0 4 8 12 16 20 24 28 32 36 40 Q [US GPM]

0 P [kPa] 600 400 200 0 H [m] 60 40 20 0 P2 [kW] 2 1 0 0 0.0 0

12

16

20

24

28

32

Q [IMP GPM] H [ft] 200 160 120 80 40 0

TM02 9088 1804

P2 [hp] 2 1 0

Q [m/h]

Eta [%] 40 20

P2 Eta

0 1 0.4 2 3 0.8 4 5 1.2 6 1.6 7 2.0 8 2.4 9 Q [m/h] Q [l/s]

Electrical data Pump type NSBasic 5-60 Voltage [V] 1x220-240 P1 P2 P2 Max. [kW] [kW] [hp] 2.7 2.5 1.8 1.8 2.5 In [A] 12.8 Capacitor [F] [Vc] 40 450 0 20 40 60 80 100 120 140 Q [l/min]

NSBasic 5-60 3x220-240/380-415

2.5 8.4/4.8

Pump type NSBasic 5-60

Dimensions [mm] A 370 B 210 C 75 D 144 E 69 F 15 G 165 I 11.5 H 268 H1 118 H2 150

DNA Rp 1

DNM Rp 1

Packing dimensions [mm] L/A 415 L/B 234 L/H 295

Vol [m3] 0.032

Weight [kg] 23.8

TM02 9017 1304

TM02 9016 1304

Electrical data

37

NSBasic

Technical data

NSBasic 6-30
0 4 8 12 16 20 24 28 32 36 40 44 48 Q [US GPM]

0 P [kPa] 400 300 200 100 0 H [m] 40 30 20 10 0 P2 [kW] 1.6 0.8 0

12

16

20

24

28

32

36

40

Q [IMP GPM] H [ft] 120 80 40 0

TM02 9090 1804

P2 [hp] 1.6 0.8 0.0

10

11 Q [m/h]

P2 Eta

Eta [%] 40 20 0

0.0 0 0.0 1 0.4 2 3 0.8 4 5 6 1.2 1.6 7 8 9 2.0 2.4 10 11 Q [m/h] 2.8 Q [l/s]

Pump type

Voltage [V] 1x220-240V

P1 P2 P2 Max. [kW] [kW] [hp] 1.56 1.1 1.1 1.5 1.5

In [A] 7.1 5.4/3.1

Capacitor [F] [Vc] 25 450 -

20

40

60

80

100

120

140

160

180Q [l/min]

NSBasic 6-30

3x220-240/380-415 1.56

Pump type NSBasic 6-30

Dimensions [mm] A 387 B 205 C 88 E 179 F 20 G 145 I 11 H 233 H1 108

DNA Rp 1

DNM Rp 1

Packing dimensions [mm] L/A 415 L/B 234 L/H 295

Vol [m3] 0.028

Weight [kg] 21.5

NSBasic 6-40
0 4 8 12 16 20 24 28 32 36 40 44 48 Q [US GPM]

0 P [kPa] 400 300 200 100 0 H [m] 40 30 20 10 0 P2 [kW] 1.6 0.8 0

12

16

20

24

28

32

36

40

Q [IMP GPM] H [ft] 120 80 40 0

TM02 9090 1804

P2 [hp] 1.6 0.8 0.0

10

11 Q [m/h]
P2 Eta

Eta [%] 40 20 0

0.0 0 0.0 1 0.4 2 3 0.8 4 5 6 1.2 1.6 7 8 9 2.0 2.4 10 11 Q [m/h] 2.8 Q [l/s]

Pump type

Voltage [V] 1x220-240V

P1 P2 P2 Max. [kW] [kW] [hp] 2 2.0 1.85 1.85 2.5 2.5

In [A] 9 6.2/3.6

Capacitor [F] [Vc] 40 450 -

20

40

60

80

100

120

140

160

180Q [l/min]

NSBasic 6-40

3x220-240/ 380-415

Pump type A NSBasic 6-40 461 387 B 205 205 C 88 88

Dimensions [mm] E 179 179 F 20 20 G 145 145 I 11 11 H 233 233 H1 108 108

DNA Rp 1 Rp 1

DNM Rp 1 Rp 1

Packing dimensions [mm] L/A 510 415 L/B 234 234 L/H 285 295

Vol [m3] 0.034 0.028

Weight [kg] 25.9 22

38

TM02 9019 1304

Electrical data

TM02 9018 1304

Electrical data

KPBasic

KPBasic

Performance range
p [kPa]
100

H [m]
10.5 10.0 9.5 600 (A)

KPBasic
50 Hz

90

9.0 8.5

80

8.0 7.5

70

7.0 6.5

300 A

60

6.0 5.5 200

50

5.0 4.5

40

4.0 3.5

30

3.0 2.5

20

2.0 1.5

10

1.0 0.5

0.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Q [m/h]

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

Q [l/s]

TM02 8937 1804

39

KPBasic

General data

KPBasic

KPBasic 200: KPBasic 300 A:

Supplied standard with 10 metres of H05 RN-F power cable. Supplied standard with 10 metres of H05 RN-F power cable. Note: 5 m cable om request. Supplied standard with 10 metres of H07 RN-F power cable. Supplied standard with 10 metres of H07 RN-F power cable. Note: 5m cable on request.

KPBasic 600: KPBasic 600 A:

Degree of protection: IP 68 Insulation class: F Manufactured according to standard EN 60335-2-41.


Gr7913

Standard voltage:

1 x 220-240V, 50 Hz 3 x 380-415V, 50 Hz.

Applications
The submersible pump from the KPBasic series is designed mainly for automatically operated fixed applications in domestic use, draining basements and garages which are subject to flooding. Thanks to its compact, easy to handle design, it can also be used as a portable pump for emergencies such as lifting water from tanks or rivers, emptying swimming pools, fountains, excavations and underpasses. It is also ideal for gardening and hobbies in general. The level switch allows fixed installation and guarantees automatic pump operation.
Table of performance ranges and possible applications DNM connections Flow rate Q [m3/h] Head H [m] Temperature t [ C] Rain water Clean waste water
o

Descriptions and materials

KPBasic Rp 1 Max. 16 Max. 10.8 Max. +40 z z

29 1 78 79 32
Pos. 1 4 29 32 Descriptions Pump body impeller O-ring gasket Stop ring Motor 54 - Top body - Shaft 78 79 Pressure disc Suction grid Stainless steel AISI 304 X5 CrNi 1810 Stainless steel AISI 304 X5 CrNi 1810 Noryl GFN 2 Noryl GFN 2 Noryl GFN 2 Noryl GFN 2 NBR Stainless steel 12E

Constructional features
Pump Water-resistant technopolymer pump body, impeller, top body and suction grid. Stainless steel motor casing, rotor shaft and screws. Triple "O" ring seals interposed with oil chamber. Motor Continous duty submersible induction motor. Stator fitted in an airtight stainless steel casing covered by a top body which encases cabling, microswitch and capacitor. Rotor mounted on oversized greased sealedfor-life ball bearings selected to guarantee silent running and long life. Built-in thermal and current overload protection and a capacitor which is permanently in circuit in the single-phase version.

4
Materials

40

TM02 8468 3204

54 73

KPBasic

Technical data

Technical data
Operation range: Liquid quality requirements: Granulometric passage though the suction grid: From 1 to 16 m3/h with head up to 10.2 metres Grey water without fibres KPBasic 200 KPBasic 300A KPBasic 600 KPBasic 600A KPBasic 200 KPBasic 300A KPBasic 600 KPBasic 600A From 0C to +35C 7 metres 1 minute Type name extension: A Other voltages and/or frequencies Fixed or portable in a vertical position. The minimum pit dimensions for fixed installation with automatic operation are indicated in the drawing. 5 mm 10 mm 10 mm 10 mm 8 mm 85 mm 38 mm 175 mm

Minimum draught depth:

Liquid temperature range: Maximum immersion: Maximum dry running time: Automatic float switch: Special versionson request: Installation:

Curve conditions
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906, Annex A.

KPBasic 300 A
Minimum dimension for the pit for KPBasic 300 A with automatic float switch

KPBasic 600 A
Minimum dimension for the pit for KPBasic 600 A with automatic float switch

400

TM02 9100 1804

500

400

400

TM02 9101 1804

41

KPBasic

Technical data

KPBasic 200
0 4 8 12 16 20 24 28 32 36 40 44 Q [US GPM] 0 P [kPa] 80 60 40 20 0 P2 [hp] 0.2 0.1 0.0 H [m] 8 6 4 2 0 P2 [kW] 0.2 0.1 0.0 0 0.0 1 0.4 0 1 2 3 4 5 6 7 8 9 10 Q [m/h] 4 8 12 16 20 24 28 32 36 Q [IMP GPM] H [ft] 25 20 15 10 5 0 Eta [%] 40

KPBasic 300A
0 4 8 12 16 20 24 28 32 36 40 44 48 52 56 Q [US GPM] 0 P [kPa] 80 60 40 20 0 P2 [hp] 0.2 0.1 0.0 H [m] 8 6 4 2 0 P2 [kW] 0.2 0.1 0.0
Eta

12

16

20

24

28

32

36 40 44 48 Q [IMP GPM] H [ft] 25 20 15 10 5 0

10 11 12

Q [m/h]

P2 Eta

P2

Eta [%] 40 20 0

TM02 9020 1304

20 0 2 3 0.8 4 5 6 1.2 1.6 7 8 9 2.0 2.4 10 Q [m/h] 2.8 Q [l/s]

0 1 2 3 0.0 0.4 0.8

4 5 6 1.2 1.6

7 8 9 2.0 2.4

10 11 12 Q [m/h] 2.8 3.2 3.6 Q [l/s]

20

40

60

80

100

120

140

160 Q [l/min]

20

40

60

80 100 120 140 160 180 200 Q [l/min]

KPBasic 200, KPBasic 300A

Liv.min.

H2

Liv.max.

H1

E B A D

Electrical data Pump type KPBasic 200 KPBasic 300A Voltage [V] 1x220-240 1x220-240 P1 Max. [W] 350 350 P2 [kW] 0.22 0.22 P2 [hp] 0.3 0.3 In [A] 1.5 1.5 Capacitor [F] 8 8 [Vc] 450 450

Pump type KPBasic 200 KPBasic 300A

Dimensions [mm] A 185 185 B 140 140 D 225 225 E 82 82 H 266 275 H1 390 390 H2 38,5 47,5

Liv. min. [mm] 100 100

TM02 8466 0204

Liv. max. [mm] 350 350

DNM Rp 1 Rp 1

Packing dimensions [mm] L/A 207 207 L/B 227 227 L/H 312 312

Vol [m3] 0.016 0.016

Weight [kg] 4.5 4.6

42

TM02 9021 1304

KPBasic

Technical data

KPBasic 600 (A)


0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 Q [US GPM] 0 P [kPa] 80 60 40 20 0 P2 [hp] 0.8 0.6 0.4 0.2 0.0 H [m] 10 8 6 4 2 0 P2 0 [kW] 0.6 0.4 0.2 0.0 0 0.0 2 4 6 8 10 12 14 16 Q [m/h]
P2 Eta

KPBasic 600 (A)


Q [IMP GPM] H [ft] 30 25 20 15 10 5 0 Eta [%] 30 20 10 0

10 15 20 25 30 35 40 45 50 55 60

TM02 9022 1304

2 0.5

4 1.0

6 1.5 2.0

8 2.5

10 12 14 3.0 3.5 4.0

16 4.5

Q [m/h] Q [l/s]

B A D

40

80

120

160

200

240

Q [l/min]

Electrical data Pump type KPBasic 600 KPBasic 600A KPBasic 600 Voltage [V] 1x220-240 1x220-240 3x380-415 P1 Max. [W] 800 800 800 P2 [kW] 0.55 0.55 0.55 P2 [hp] 0.75 0.75 0.75 In [A] 3.4 3.4 3.4 Capacitor [F] 14 14 [Vc] 450 450 -

Pump type KPBasic 600 KPBasic 600A

Dimensions [mm] A 200 200 B 160 160 D 225 225 E 90 90 H 376 376 H1 490 490 H2 73 73

Liv. min. [mm] 200 200

Liv. max. [mm] 450 450

DNM Rp 1 Rp 1

Packing dimensions [mm] L/A 207 207 L/B 227 227 L/H 422 422

Vol [m3] 0.021 0.021

Weight [kg] 7 6.7

TM02 8466 0204

Liv.min.

H2

Liv.max.

H1

43

PFBasic

PFBasic

Performance range
p [kPa]
600

H [m]
60

PF(P)Basic
50 Hz
PFPBasic 2-50

55 500

50 PFBasic 2-50 45

400

40

35 300

PFBasic 1-30

30

25

200

20

15

100

10

0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8

Q [m/h] Q [l/s]
TM02 8935 1804

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

44

PFBasic

General data

PFBasic

1 28 4

16

Applications
Peripheral centrifugal pump with compact dimensions. Able to generate high heads and suitable for domestic installations, water supply systems, light gardening applications, draining and filling cisterns, as well as light industrial uses such as feeding pressurized boilers (anticondensation).

Material specification
Pos. 1 4 7 16 28 Description Pump body Impeller Shaft Mechanical seal O-ring gasket Material Cast iron EN-GJL-200 Brass PCu Zn 40 Pb2 5705-65 Stainless steel AISI 416 X12 CrS 13 Carbon/ceramic NBR rubber

Constructional features
Pump Cast iron pump body and motor support with brass wear disc. Brass impeller. Carbon/ceramic mechanical seal. Motor Induction motor, closed and cooled with external ventilation. Rotor mounted on oversized greased sealed-forlife ball bearings to ensure silent running and long life. The motor incorporates a built-in thermal and current overload protection as well as a capacitor, switched on permanently. Manufactured according to standard EN 60335-2-41. Motor protection: Terminal box protection: Insulation class: Standard voltage: IP 44 IP 55 F Single-phase 220-240 V, 50 Hz.

Other voltages and frequencies are available on request.

TM02 9071 1704

GR7901

45

PFBasic

Technical data

Technical data
Operating range: Pumped liquid: Liquid temperature range: From 0.3 to 2.7 m3/h with heads up to 53 metres. Cclean, free from solids or abrasive substances, non viscous, non aggressive, non crystallized, chemically neutral, close to the characteristics of water. from 0C to +35C for domestic use (EN 60335-2-41) From 10C to +50C for other uses. Maximum ambient temperature: +40C Maximum operating pressure: Installation: - PFBasic 1-30: 6 bar (600 kPa) - PFBasic 2-50: 10 bar (1000 kPa) Fixed in the horizontal position.

The performance curves are based on a kinematic viscosity value of 1 mm/s and a density equal to 1000 kg/m3. Curve tolerances according to ISO 9906, annex A.
p [kPa] H [m] 56 52 480 400 320 240 160 80 0
TM02 9091 1804

2-50

PFBasic
50 Hz
ISO 9906 Annex A

48 44 40 36 32 28 24 20 16 12 8 4 0 0.0 0.0 0.4 0.8 0.2 1.2 1.6 0.4 1-30

0.6

Q [l/s]

Electrical data
Model PFBasic 1-30 PFBasic 2-50 Voltage [V] 1 x 220-240 1 x 220-240 P1 max. [kW] 0.47 0.86 P2 [kW] 0.3 0.6 P2 [hp] 0.4 0.8 In [A] 2 3.8 Capacitor [F] 8 12.5 [Vc] 450 450

Dimensions and weights


Model PFBasic 1-30 PFBasic 2-50 A 228 255 B 132 130 B1 165 C 22 26 E 46 106 F 80 G 65 100 I 8 7 H 158 186 H1 103 108 H2 138 153 DNA Rp 1 Rp 1 DNM Rp 1 Rp 1 Packing dimensions [mm] L/A 259 271 L/B 164 176 L/H 197 209 Volume [m 3] 0.008 0.01 Weight [kg] 5.3 7.5

46

TM02 6757 1304

2.0

2.4 Q [m/h]

PFPBasic

General data

PFPBasic 2-50
1 3 28 7

Gr7900General data

16

Applications
Self-priming pump with side liquid channel and starshaped impeller, with excellent suction capacities even in unfavourable operating conditions such as the presence of air bubbles or lack of continuity in the sucked liquid. Used in domestic, agricultural civil and industrial installations.

Materials
Pos. 1 3 4 7 Description Pump body Motor support Impeller Shaft Mechanical seal O-ring gasket Material Cast iron EN-GJL-200, with brass wear ring PCuZn 40 Pb2 5705/65 Brass PCu Zn 40 Pb2 5705/65 Brass PCu Zn 40 Pb2 5705/65 Stainless steel AISI 416 X12 CrS 13 Carbon/ceramic FKM

Constructional features
Pump Cast iron pump body with brass pressure disc. Motor support and impeller completely made of brass, to avoid the risk of blockage. Carbon/ceramic mechanical seal. Stainless steel motor shaft. Motor Asynchronous motor, cooled by external fan. Rotor mounted on oversized, greased and sealed-for-life ball bearings to ensure quiet operation and long life. The single-phase version has built-in thermal and current overload protection. Manufactured according to standard EN60335-2-41. Motor protection: Insulation class: Standard voltage: IP 44 IP 55 terminal board protection F Single-phase 220-240 V, 50 Hz. Other voltages and frequencies are available on request.

16 28

TM02 9072 1704

47

PFPBasic

Technical data

Operating conditions
Operating range: Pumped liquid: Liquid temperature range: From 0.5 to 2.7 m3/h with heads up to 53 metres. Clean, free from solids or abrasive substances, non-aggressive, noncrystallized, chemically neutral, similar to the characteristics of water. From 10C to +80C

Maximum ambient temperature: +40C Maximum operating pressure: Installation: 10 bar (1000 kPa) Fixed in the horizontal position.

The performance curves are based on a kinematic viscosity value of 1 mm/s and a density equal to 1000 kg/m3. Curve tolerances according to ISO 9906, annex A.
p [kPa] H [m] 56 52 480 400 320 240 160 80 0
TM02 9092 1804

PFPBasic 2-50
50 Hz
ISO 9906 Annex A

48 44 40 36 32 28 24 20 16 12 8 4 0 0.0 0.4 0.8 0.0 0.2 1.2 1.6 0.4 2.0

0.6

0.8 Q [l/s]

Electrical data
Model PFPBasic 2-50 Voltage [V] 1 x 220-240 P1 max. [kW] 1.05 P2 [kW] 0.75 P2 [hp] 1 In [A] 4.7 Capacitor F 20 Vc 450

Dimensions and weights


Model PFPBasic 2-50 A 301 B 142 C 38 E 136 F 90 G 112 I 7 H 206 H1 146 H2 187 DNA Rp 1 DNM Rp 1 Packing dimensions [mm] L/A 406 L/B 267 L/H 402 Volume [m3] 0.044 Weight [kg] 10.7

48

TM02 6758 1304

2.4

2.8 Q [m/h]

49

50

51

Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence

96548246 0804 - c1

GB
Subject to alterations.

GRUNDFOS A/S . DK-8850 Bjerringbro . Denmark Telephone: +45 87 50 14 00. www.grundfos.com