Você está na página 1de 34

NetAct Optimizer 3.

0 Basic
Graphical Adjacency Management

For public us e IPR applies 1 Noki a Si emens N etwor ks .8.2010

Presentation / PLe /23

Nokia Siemens Networks Academy


Legal notice Intellectual Property Rights
All copyrights and intellectual property rights for Nokia Siemens Networks training documentation, product documentation and slide presentation material, all of which are forthwith known as Nokia Siemens Networks training material, are the exclusive property of Nokia Siemens Networks. Nokia Siemens Networks owns the rights to copying, modification, translation, adaptation or derivatives including any improvements or developments. Nokia Siemens Networks has the sole right to copy, distribute, amend, modify, develop, license, sublicense, sell, transfer and assign the Nokia Siemens Networks training material. Individuals can use the Nokia Siemens Networks training material for their own personal self-development only, those same individuals cannot subsequently pass on that same Intellectual Property to others without the prior written agreement of Nokia Siemens Networks. The Nokia Siemens Networks training material cannot be used outside of an agreed Nokia Siemens Networks training session for development of groups without the prior written agreement of Nokia Siemens Networks.

For public us e IPR applies 2 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Module Objectives
At the end of this module the trainee should be able to: Fix adjacencies with incorrect settings Create and modify adjacency template assignment rules Create, modify and delete adjacencies and adjacency constraints manually using Map, Navigator, and Browser

For public us e IPR applies 3 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Graphical Adjacency Management


How to fix invalid adjacencies? How to get correct default values to new adjacencies? How to create, delete, and modify adjacencies manually?

For public us e IPR applies 4 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Invalid Adjacencies
Adjacencies to slave BTS (ADCE and ADJG) Adjacencies where "Target Cell DN" does not match with Cell ID and LAC of target GSM cells with Cell ID and RNC ID of target WCDMA cell Adjacencies that have no "Target Cell DN" specified These should be fixed before continuing Correction plan is created in Optimizer Export to CM DB Provision

For public us e IPR applies 5 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Fix Invalid Adjacencies


See Details Select the type(s) Click Fix selected Close Select File->CM Data Exchange... Export automatically created plan to CM DB Provision the plan

For public us e IPR applies 6 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Graphical Adjacency Management


How to fix invalid adjacencies? How to get correct default values to new adjacencies? How to create, delete, and modify adjacencies manually?

For public us e IPR applies 7 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Adjacency Templates
Templates are created and managed in CM Editor

For public us e IPR applies 8 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Adjacency Template Assignments


Rules have to be created for the template assignment

System template used if no rules or conflicting rules exist The priority of the rules is (in the order of importance) assigned cell template name (GSM and WCDMA) cell type (GSM) frequency band in use (GSM) frequency (WCDMA) * wildcard character (GSM and WCDMA) Rules are not user specific
For public us e IPR applies 9 Noki a Si emens N etwor ks Presentation / PLe /23.8.2010

Template Assignment Rules


Select a BSC, an RNC, or Common Cluster Assignment Rules and click Add

For public us e IPR applies 10 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Adjacency type
Select adjacency type for rule creation ADJW used as an example Then select source and target categories Different possibilities for GSM and WCDMA source and target Asterisk (*) is a wild card (any selection)

For public us e IPR applies 11 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Categories for GSM adjacencies


Select category for source or target BTSs Copy and paste can be used for additional rules BTSs must have the template name assigned for these rules to work

For public us e IPR applies 12 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Categories for WCDMA Adjacencies


Select category for source or target WCELs

For public us e IPR applies 13 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Template Name for the Rule


Select a template to be used for a new adjacency that has the specified categories for source and target cells Example: When creating an adjacency from a GSM900 cell to a WCDMA cell with frequency F1, Optimizer automatically assigns default values from ADJW template System (External) New templates become visible in Optimizer after clicking Refresh

For public us e IPR applies 14 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Exercise
Check the available templates for adjacencies in CM Editor You can also create a new template from one of the existing ones Create one or more rules for BSC or RNC utilising this new template

For public us e IPR applies 15 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Graphical Adjacency Management


How to fix invalid adjacencies? How to get correct default values to new adjacencies? How to create, delete, and modify adjacencies manually?

For public us e IPR applies 16 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Viewing Adjacencies
Locate or select a cell on the map Use cell popup menu to show all adjacencies Check Default Visibility Settings for the colors

For public us e IPR applies 17 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Adjacency Lines
Adjacency selection is bidirectional by default Use Alt button for unidirectional adjacency selections Use Ctrl button for multiple selections Single selection also selects the source and target cells

For public us e IPR applies 18 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Visualizing Neighbors
Select Neighboring cells for Cell Icon visualization Neighbors are colored with orange Neighbors neighbors are colored with yellow

For public us e IPR applies 19 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Cell Labels in GAM


Cell labels can be used in Graphical Adjacency management to display the number of outgoing adjacencies for a cell Total number or type specific number of outgoing adjacencies

For public us e IPR applies 20 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Adjacency Icons
To create or delete adjacencies or adjacency constraints use icons on the right side of the map If a plan is not open, Optimizer prompts to create or open one Create bi-directional adjacency Create uni-directional adjacency Create bi-directional forbidden constraint Create uni-directional forbidden constraint Create bi-directional mandatory constraint Create uni-directional mandatory constraint Delete selected adjacency (only active if one or more adjacencies are selected)
For public us e IPR applies 21 Noki a Si emens N etwor ks Presentation / PLe /23.8.2010

1. 2.

3. 4.

5. 6.

7.

Creating Adjacencies, Method 1


If a plan is not open the user is prompted to open or create one Activate adjacency creation button on the map toolbar Press and hold down the left mouse button on top of the source cell icon Move on top of the target cell icon until the icon is selected Release the mouse button Adjacency line(s) drawn between the cells It is also possible to create uni-directional adjacencies to foreign target cells Cell labels show if more adjacencies can be created for a cell
For public us e IPR applies 22 Noki a Si emens N etwor ks Presentation / PLe /23.8.2010

New Adjacencies
Adjacency creation is active until selection arrow or a new tool is selected

For public us e IPR applies 23 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Creating Adjacencies, Method 2


Open the cell pop-up menu and set the cell as a source The selected cell icon turns red Use mouse (and Ctrl-button) to select one or more cells as targets

For public us e IPR applies 24 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Creating Adjacencies, Method 2

Source cell

To clear the source selection use map toolbar button, or select another source cell
For public us e IPR applies 25 Noki a Si emens N etwor ks Presentation / PLe /23.8.2010

Creating Adjacencies in Navigator


Select two cells with a mouse and Ctrl-button

For public us e IPR applies 26 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Creating Adjacencies based on Cell Identification


Tools->Adjacency Optimization->Cell Identification based Adjacency Management

You can also use cell selection popup menu to start the creation

For public us e IPR applies 27 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Deleting the Selected Adjacencies


Verify that you have a plan open Select one or more adjacencies on the map and use pop-up menu or toolbar button to delete the selected adjacencies If the adjacency to be deleted is an actual object it changes color or disappears according to default visibility settings If the adjacency to be deleted is a new (created) one it disappears (removed from plan) Adjacencies can also be deleted in the Browser and Navigator
For public us e IPR applies 28 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Adjacency Management Matrix


An easy way of managing intra SITE adjacencies and constraints Also usable for dependencies between selected cells Start by selecting a site or some cells from the map

For public us e IPR applies 29 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Adjacency Management Matrix


Find the source cell from the second column and find target cell from the same row and click the cell in the crossing New adjacencies automatically visible on the Map

For public us e IPR applies 30 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Instant Adjacency Provisioning


Planned adjacency changes can be provisioned to the network directly from the Browser or from the Map (with sufficient user rights) Provisioning is done in the background using CM Operations Manager More information in the coming module "Provisioning"

For public us e IPR applies 31 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Exercise
Practise creating new adjacencies in both ways presented! Use cell labels to find adjacencies that have a full adjacency list How can you verify that the created adjacencies get the correct template? Study default visibility settings effect on the adjacency creation and deletion (line color and visibility) Use Adjacency Management Matrix to check sites for missing adjacencies

For public us e IPR applies 32 Noki a Si emens N etwor ks

Presentation / PLe /23.8.2010

Summary
There are six kinds of adjacencies in Optimizer ADCE between GSM cells ADJW and ADJG between GSM and WCDMA cells ADJD, ADJS and ADJI between WCDMA cells Invalid adjacencies may not display correctly in Optimizer and should be fixed before continuing adjacency management or optimization Adjacent cell templates can be created and modified in CM Editor Template assignment rules are created in Optimizer Adjacencies can be created and deleted on the Map and Navigator Adjacency Management Matrix can be used to manage intra site adjacencies Small adjacency plans can be provisioned directly from the Browser
For public us e IPR applies 33 Noki a Si emens N etwor ks Presentation / PLe /23.8.2010

Document change history


Date Version Nam e Change comment

23.8.2010

1.0

PLe

First draft for Optimizer 3.0

For public us e IPR applies 34 Noki a Si emens N etwor ks