Você está na página 1de 5

ASHIDA Numerical UV/OV Protection Relay

Features:

Type : ADR 132 B : ADR 232 B


(ADITYA Series)

3 Phase start connected, full under / over voltage protection. Programmable (Non- Volatile) Setting By local keys Back - lit LCD display for settings. Display of fault voltage / Load voltage. Wide Under voltage range 45% to 100% (100% = bypass under voltage element). Wide Over voltage range 100% to 155% (100% = bypass over voltage element). Design using DSP technology. Latching of fault value. Pass-word protection for setting. RS232 / RS 485 Communication (ADR 232 B).

Cutout: 138 x 138mm Bezel: 160 x 160mm

General :
The ADR132B is member of Ashida Numerical Relay family (Aditya Series) design to meet demand of low and medium switchgear control. The ADR132B is basically 3 phase Under/Over voltage protection with definite time. The ADR132B continuously monitors all 3 phase voltage, through PT connections. The high-speed micro-controller samples this voltage sine wave through a 12 bit A/D converter. The microcontroller performs powerful Digital Algorithms to find out Amplitude of voltage signal, and then this value is use for protection and metering function. All measurement is tuned to fundamental frequency and reject all higher harmonics present in electric supply. Each phase voltage is also displayed on 16 x 2 LCD display for metering. The Relay is having main three functions 1) Protection 2) SelfSupervision 3) Measurement. 1. Protection Functions: The ADR132B give maximum benefit/cost ratio. The ADR132B give all the advantage of numerical relay at affordable cost. Following is summery of different protection functions provided by relay. ANSI IEC Protection Functions 27 59 1.1. Definite time under voltage Protection Definite time over voltage Protection

Over / Under voltage protection: The ADR132B has 3 sensing element, each is connected to monitor phase to neutral voltage. The tripping voltage can be set to 45% to 100% for under voltage and 100% to 155% for over voltage. Where 100% = rated line to neutral voltage. The display can be programmed to display primary voltage directly, The under voltage and over voltage sections has got independent time setting. ( 1 10sec).

Note: Due to our policy to upgrade our products constantly, we reserve the right to supply products which may vary slightly from that indicated above.
ASHIDA ELECTRONICS PVT LTD. Plot No. A-308, Road No. 21, Wagle Industrial Estate, Thane (W)-400 604. INDIA. E-mail: sales@ashidaelectronics.com Web: www.ashidaelectronics.com

Ref.: ADR132B Issue : 02 06.07.05 Page 1/3

Type : ADR 132 B : ADR 232 B


(ADITYA Series)

The high speed CPU continuously monitor the all three voltage inputs and compare with UV/OV setting. If any one voltage is above OV setting or below UV setting, CPU calculate start timer and provides trip command if fault is persist even after this time delay. All the settings are password protected to prevent unauthorised change. 2. 2.1 Supervision Function: Self-supervision: The relay is continuously keeping track on its internal hardware and the movement it detects any failure of any component, it gives message on LCD display, This feature is very useful to give pre information to avoid any mall - operation. In such situation it use some default setting and remain in protection mode. Measurement Function and communication: In normal condition this display shows all settings. Via keyboard the display can be programmed to show the actual voltage across relay coil. If voltages deviate from UV/OV settings the relay gives trip command. The type of fault is displayed on LCD display. During the fault condition the relay measure the fault voltage and store in non-volatile memory. The fault current can be read via keyboard on LCD display Last 3 fault values along with tripping counter can be view via key-board. All settings are save in Electrically erasable read only memory and remain.

3.

Technical Specifications:
Sr. No. Specification I. Inputs Protection Relay Setting Range Particulars : Suitable for PT secondary 63.5V / 230V Phase neutral (To be specified.) : For Under voltage : For Over Voltage : For Under voltage timer : For Over voltage timer II. III. IV. V. VI. VII. VIII. IX. Pickup Current Resetting Current Time Accuracy Burden on PTs Aux. Supply Burden on Aux. Supply Control Contacts Contact Rating Trip Duty - 45 - 100 % in step of 1%. (100% = bypass) - 100 - 155% in step of 1% (100% = bypass) - 1 10 sec in steps of 1sec - 1 10 sec in steps of 1sec

: Within 1.05 times of set over voltage : Within 0.95 times of set under voltage. : Within 90% of set value. For over voltage : Within 110% of set value. For under voltage : Within class 2.5 As per IS: 3231. : Less than 1.0VA. : 18 - 52VDC or 77 - 250VDC. To be specified while ordering. : Less than 10VA on any supply. : 2 NO contacts (SR ) are given for Trip & Annunciation. - Trip Duty : Make and carry for 3sec. 7500VA with max. 30A & 660VAC/DC : Make and carry for continuous - 1250VA with max. 5A & 660VAC/DC : Break AC - 1250 VA DC - 100 W resistive 50W inductive.

Note: Due to our policy to upgrade our products constantly, we reserve the right to supply products which may vary slightly from that indicated above.
ASHIDA ELECTRONICS PVT LTD. Plot No. A-308, Road No. 21, Wagle Industrial Estate, Thane (W)-400 604. INDIA. E-mail: sales@ashidaelectronics.com Web: www.ashidaelectronics.com

Ref.: ADR132B Issue : 02 06.07.05 Page 2/3

Type : ADR 132 B : ADR 232 B


(ADITYA Series)

X.

Operational Indicators (Flags) ON : Green LED indicates Relay OK : In case of following condition led become off 1. Problem in relay Hardware. 2. Auxiliary supply is not sufficient for relay operation. FAULT : Red LEDs indicates the UV/OV relay trip, Hand Reset (HR) Type. PKP : Red LED indicates relay pickup (timer start) TRIP : Indicates that Trip pulse is being executed. When BYPASS P.B. is pressed, actual trip is not executed. Thermal Withstand Capacity High Voltage Test : x2 times the rated voltage for 3sec. : x1.5 Continuous : IEC 60255-5 : Except DC Voltage and RS485 input 2.0 kV (RMS), 50Hz : Only DC voltage supply and RS485 - 2.8 kV DC : Between Open contact of TRIP / CLOSE 1.5kV (RSM) 50Hz : Between Open contact of ALARM 1kV (RSM) 50Hz : IEC60255-5 : 5kV (peak) 1.2 / 50us, 0.5 J, 3 positive and 3 negative impulse at interval of 5 sec : IEC 60255-22-1, Class III : 2.5 kV (peak) 1MHz , = 15s 400 surges / s duration 2 s : IEC 60255-22-2 Class III and IEC 61000-4-2 class III : 4kV/6kV contact discharge, 8kV air discharge, both polarities 150pF, Ri 330 : IEC 60255-22-3 and IEC 61000-4-2 class III : 10V/m; 80 to 1000MHz; 80%; 1kHz AM : IEC 60255-22-3 and IEC 61000-4-3, class III : 4kV; 5/50ns; 5kHz burst duration = 15ms; : Repetition rate 300ms; Both polarities; Ri = 50; duration 1 min. : IEC 60255-21-2 class 1 : Semi-Sinusoidal : 5g acceleration, duration 11ms, : Each 3 shocks in both direction of the 3 axes : IEC 60255-21-1 class 1 / IEC 60068-2-6 : Sinusoidal 10 to 60Hz 0.035 mm : Amplitude, 60 to 150Hz, 0.5g acceleration : Sweep rate 1 octave/min; 20 cycle in 3 orthogonal : For Cabinet Type - CSA -150 (MAC00101) : For Electrical Connection - APD00802

XI. XII.

XIII.

Impulse Voltage Test (all circuit class III) High Frequency test Electro static Discharge

XIV. XV.

XVI.

Irradiation with radio frequency field, pulsemodulated, Fast transient interference/bursts Shock Test

XVII.

XVIII.

XIX.

Vibration Test

XX.

Drawing References

Note: Due to our policy to upgrade our products constantly, we reserve the right to supply products which may vary slightly from that indicated above.
ASHIDA ELECTRONICS PVT LTD. Plot No. A-308, Road No. 21, Wagle Industrial Estate, Thane (W)-400 604. INDIA. E-mail: sales@ashidaelectronics.com Web: www.ashidaelectronics.com

Ref.: ADR132B Issue : 02 06.07.05 Page 3/3

Você também pode gostar