Você está na página 1de 40

Technical Information

Proservo NMS5
Intelligent tank gauge with high accuracy performance Liquid level, I/F, Density & Density Profile

Application The Proservo NMS5 of intelligent tank gauges is designed for high accuracy liquid level measurement in storage and process applications. It fulfills the exact demands of tank inventory management, loss control, total cost saving and safe operation. Typical areas of application include: Oil (fuels) LPG/LNG Chemicals Water / chemical interface measurement Alcohols

Features and benefits SIL2 Certified Measures liquid to an accuracy of +/- 0.7 mm Measures two clear interface levels and specific gravity of up to three liquid phases Profiling of Iiquid density throughout the tank (Tank profile) and upper layer (I/F profile) Latest microtechnology keeps the design simple, lightweight and compact Wetted parts are completely separated from the electronic circuit Tank top mounting with 3 flange weighing only 12kg (aluminum version) Wide range of output signals including V1, RS 485, WM550, M/S, Enraf BPM and HART protocol Material and pressure rating of the wetted parts can be selected according to the application. Suitable for atmospheric and high pressure applications up to 2.45MPa/24.5bar Maintenance prediction of the instrument Direct connection of spot or average temperature probes Easy to program using the E+H matrix system Robust IP67/NEMA 4X housing Selectable English, Japanese or Chinese display Proactive safety diagnostics output to display and System Operators (patent pending)

Tank mounted intelligence makes the Proservo NMS5 ideal for single or multi-task installation, converting a wide range of measurement functions including: Liquid level Interface level Spot density Density profile Tank bottom Water dip

TI 00452G/08/EN/02.11 71136221 Software Ver. V.4.27F

Proservo NMS5

Table of Contents
Function and system design . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Measuring System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 System Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Major Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operating Principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Typical Tank installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Measurement terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Application Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Displacer Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Displacer Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Recommended displacer by Application . . . . . . . . . . . . . . . . . . . .8 Point to confirm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Custody Transfer: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Material compatibility: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Process connection size: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Input for local devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Output parameters based on communication protocol . . . . . . . .10 RS485 Modbus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Bidirectional serial pulse (V1 protocol) . . . . . . . . . . . . . . . . . . . .11 HART Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Whessoematic 550 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Mark / Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Enraf Bi Phase Mark (BPM) . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Analogue output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Anxiliary energy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 V1 Serial Pulse Modbus RS 485 HART Enraf BPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Whessoematic 550 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Mark / Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Cable entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Power consumption. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Safe electrical isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Performance characteristics . . . . . . . . . . . . . . . . . . . . . . . . . 19 Maximum measured error . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 Compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 Operating conditions : Environment . . . . . . . . . . . . . . . . . . 20 Modbus (RS485 Output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Sakura V1 Serial Pulse Ouput . . . . . . . . . . . . . . . . . . . . . . . . . .20 Enraf Bi Phase Mark Output . . . . . . . . . . . . . . . . . . . . . . . . . . 21 HART Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 Whessoematic 550 (WM 550) Output . . . . . . . . . . . . . . . . . . . 21 Varec Mark Space (M/S) Output . . . . . . . . . . . . . . . . . . . . . . . Ambient temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Liquid temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Degree of protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 22 22 22 22

Operating condition : Process . . . . . . . . . . . . . . . . . . . . . . . 23 Process pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Measuring range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Mechanical construction . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Design, dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Housing materials of Construction . . . . . . . . . . . . . . . . . . . . . . 24 Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Flange type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Measuring wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Displacer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Cable entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Human interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Operating concept . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Display(LCD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Memo function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Advanced Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Maintenance Prediction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Proactive Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Certificates and Approval . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Ex approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Custody transfer approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Overspill prevention . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 External standards and guidelines . . . . . . . . . . . . . . . . . . . . . . 28 Ordering information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Proservo NMS5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Calibration Chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Power+Control Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Ball Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Reducing Flange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Supplementary Documentation . . . . . . . . . . . . . . . . . . . . . . 38 Technical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Operating Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Compact Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Stainless Steel conversion table . . . . . . . . . . . . . . . . . . . . . . . . 39

Endress+Hauser

Proservo NMS5

Function and system design


Measuring System The Proservo NMS5 is an intelligent tank gauge for high accuracy liquid level measurement employing the latest microprocessor technology. As well as level measurement, Proservo NMS5 can determine the interfaces between three liquids, specific gravity of these liquids and tank bottom. To enable accurate volume calculation or simply for indication, Proservo NMS5 will accept an input from either an average temperature probe NMT 53x series (via twisted pair cables, HART protocol) or via spot temperature element (via 3 wire Pt. 100 RTD signal). Once installed, all calibration and operating functions can be made via the user friendly Matrix program and touch sensitive keypad. Tank side monitoring and operation can be performed by the Promonitor NRF 560.

Power (AC / DC) Output Prothermo Proservo

HART

Temp.

Level Interface Density Water dip Bottom

Promonitor

Power (AC / DC)

Power (AC / DC)

HART

Power (AC / DC)

HART to a HOST system in a control room

Endress+Hauser

Proservo NMS5

System Configuration

From single tank level measurement to the largest oil refinery application, Proservo is an integral part of tank farm management solutions. A wide variety of data output protocols is available for seamless integration into many commonly used systems. The primary example is Endress+Hausers revolutionary Tankvision, a scalable concept offering local tank management for up to 225 tanks via Modbus, V1 or Whessomatic 550 protocols. Collected data is available to DCS and other plant management systems via a Host Link. Output protocols Modbus, RS485 or current loop V1 serial pulse Whessomatic 550 local HART Mark/Space Enraf BPM

Modbus

SCADA DCS/PLC

Host Link Device Cong

LAN

TCP/IP

Data Concentrator Data Scanner (Field Protcol) V1, Modbus Data Scanner

HART

HART

HART

Proservo NMS5 system configuration Serial pulse output

Major Application

The number of measuring functions and output options as well as the lightweight compact design enables Proservo NMS5 to be installed in a wide range of applications at minimal cost.

Petroleum Industry From the production of oil to storage at an oil depot, there is a need to measure and manage a wide variety of products. A remote tank gauging and inventory management system combined with Proservo NMS 5 and a receiving computer is an ideal way to measure and control the contents of the tanks. Chemical Industry For this industry, a wide choice of materials is available for the construction of the wetted parts, to ensure chemical compatibility and long life. Power Plant Fuel oil levels are major applications where precise measurement is required to ensure safe operation.

Endress+Hauser

Proservo NMS5

Operating Principle

The Proservo NMS5 tank gauging system is based on the principle of displacement measurement. A small displacer is accurately positioned in the liquid medium using a servo motor. The displacer is suspended on a measuring wire which is wound onto a finely grooved drum housing within the instrument. The drum is driven via coupling magnets which are completely separated by the drum housing. Outer magnets are connected to the wire drum whilst the inner magnets are connected to the drive motor. As the magnets turn, its magnetic attraction causes the outer magnets to turn as well, as a result turning the entire drum assembly. The weight of the displacer on the wire creates a torque on the outer magnets generating the change of magnetic flux. These changes generated between the drum assembly are detected by a unique electromagnetic transducer on the inner magnet. The drive motor is actuated to balance the voltage generated by the variations of magnetic flux to equal the reference voltage defined by the operating command. When the displacer is lowered and touches the liquid, the weight of the displacer is reduced because of the buoyant force of the liquid. As a result, the torque in the magnetic coupling is changed and this change is measured by 5 sets of Hall sensors, (patented) chips which are temperature compensated. The signal, an indication of the position of the displacer, is sent to the motor control circuit. As the liquid level rises and falls, the position of the displacer is adjusted by the drive motor. The rotation of the wire drum is precisely evaluated to determine the level value.
Outside magnet Wire drum Inside magnet Weight signal Weight data

Hall element

Measurement wire Displacer position data Motor drive signal Encoder

Motor Displacer
Direct Torque Detection

Endress+Hauser

Proservo NMS5

Typical Tank installation


Proservo NMS5
E +

Proservo NMS5 E-+ Prothermo NMT539

Prothermo NMT539

Ball Valve

Reducer

Measuring wire Displacer

Meas. Wire

Displacer

Still well

Still well

Fixed roof tank with stilling well

High pressure tank with stilling well and ball valve

Proservo NMS5
E +
E -

Proservo NMS5
Prothermo NMT

Measuring wire

Measuring wire

Displacer
Displacer

Still well

Floating roof tank and/or covered floating roof tank

Note: When the Proservo is installed on Floating roof tank, be sure to use Stilling Well

Endress+Hauser

Proservo NMS5

Measurement terminology

Level Upper Density

Upper I/F Middle Density Middle I/F Lower Density

Tank Bottom

Proservo NMS5 with standard level, I/F x 2, Tank bottom and spot density x 3 measurement

I/ F Prole True average density within Upper layer

Tank Prole True average density throughout the tank

Level

Density measured point (2 ~ 16 points selectable) between level to upper I/F

Density measured point (2 ~ 16 points selectable) Throughout liquid

Oil

Upper I/F
Emulsion

Water

Tank oor

Left: Density Profile measurement "I/F (Interface) Profile" measurement range Right: Density Profile measurement "Tank Profile" measurement range

Endress+Hauser

Proservo NMS5

Application Selection
Displacer Selection Guide A wide variety of displacers are available to meet your applications. Proper displacer selection ensures optimal performance and longevity. The following guidelines will assist you to select the best displacer for your application.

Displacer Types
30mm 40mm 50mm 70mm 110mm

(Standard materials available)


316 Alloy C PTFE

Recommended displacer by Application


Application Viscous Surface 50mm PTFE Interface Not Recommended 50mm 316 50mm PTFE 50mm 316 50mm 316 70mm 316 50mm Alloy C 50mm PTFE N/A Density Not Recommended 50mm 316 50mm PTFE 50mm 316 50mm 316 50mm 316 50mm Alloy C 50mm PTFE N/A

Crude

50mm 316 50mm PTFE 50mm 316 50mm 316 70mm 316 50mm Alloy C 50mm PTFE 70mm 316 110mm 316

Black oil White oil Liquefied gases, LPG/LNG Aggressives

Custody Transfer

Note! The above table is for 80A (3") mounting flange or larger.

Endress+Hauser

Proservo NMS5

Point to confirm

Application: What is the primary measurement function? Most applications can be generalized into three requirement cases: Level data, Density data, or Level and Density data. Proservo is primarily a Hi-accuracy Level measurement instrument, with the additional ability to measure density. Level measurement includes finding the liquid surface level, the interface level(s) between different liquids, and as well finding the tank floor or datum plate. Density measurement includes single-point (called spot measurements), as well as profile measurements of the entire liquid(s) in a tank. Surface Level: In general, larger diameter displacers give higher accuracy under similar conditions. Interface Level(s): Cylindrical shape displacers, with rounded top and bottom, reduce the resistance while moving through the liquid(s). Therefore, a cylindrical shape usually provides smoother movement and faster interface measurements compared to flat-bottom displacers, especially for density profile measurements that span the full tank height. Note that, in order for a displacer to travel down through the liquid(s), the density of a displacer (its weight divided by its volume) must be higher than the density of the liquid(s). Tank-bottom / datum plate Level: (same as for Interface Levels) Density: Since the density measurement is the calculated result of two of more measurements, a displacer with higher volume will usually yield the most accurate density measurement. In most cases we recommend our 50mm diameter displacer for density measurement. Note that, in order for a displacer to travel down through the liquid(s), the density of a displacer (its weight divided by its volume) must be higher than the density of the liquid(s). Level and Density: When an application calls for equal importance placed on both Level and Density measurements, the 50mm diameter, cylindrical displacer gives the best all-around performance.

Custody Transfer:

What is the requirement for Custody Transfer approval? The 70mm, conical, 316 displacer is the choice for requirements per NMi The 110mm, conical 316 displacer is the choice for requirements per PTB What are the liquid(s) characteristics? Displacers are available in three different materials as standard. Material compatibility should be confirmed to ensure safe operation and optimal Proservo performance. 316: Stainless steel is a highly versatile industrial material and provides good compatibility with a wide range of chemicals, including most white and black oils. AlloyC: This high-performance material is harder than 316, and provides excellent resistance to the many of the most severe corrosive chemical applications.

Material compatibility:

PTFE: One of the most well-known and versatile polymer materials, this high-performance material has one of the lowest coefficients of friction. It provides excellent performance in viscous/sticky liquids, and also has excellent chemical resistance to a wide range of corrosives

Process connection size:

The process connection defines the entry into the tank process, and may affect the size of displacer. The standard Proservo process connections start at 3/DN80 and fit most tank gauging applications. Accordingly, most applications can be covered with one of the 50mm and 70mm displacer choices. Smaller diameter displacers are available when the process connection is smaller. Note that, when the 110mm diameter custody transfer approval (PTB) displacer is selected, a separate calibration and maintenance chamber is recommended between the Proservo and the tank process connection.

Endress+Hauser

Proservo NMS5

Input
Input for local devices Signal Power supply Additional units Multi drop local HART protocol max. 4 devices DC 24V NMT 53x average temperature sensor NRF 560 field data processor Other - compatible HART devices Spot temperature Pt 100 Ohm ISO standard three wire connection

Output
Output parameters based on communication protocol
V1(new) V1 (old) MODBUS HART WM550 ENRAF M/S

Level Temperature (Product) Vapor Temperature Upper I/F (Water Level) *1 Middle I/F Upper Density *2 Middle Densuty*3 Lower Density*4 Average Density *5 1-16 points Individual Density *6 Multi-Element Temperature HART device input (Device 1) HART device input (Device 2) Alarm data Protocol Documentation

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes -

Yes Yes Yes -

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes KA0002N

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes -

Yes Yes Yes Yes Yes

Yes Yes Yes -

Yes Yes -

Yes Yes Yes Yes Yes KA001N

-Yes -

Remarks 1. Upper I/F output value can be either selected from the Proservos own displacer measurement or Water Bottom measured value via the Prothermo NMT 539. 2. A single point density measurement within the upper layer liquid in the tank. The measurement position is configured to 150mm below the liquid surface at default. 3. A single point density measurement within the middle layer liquid in the tank. The measurement position is configured to 150mm below the upper interface level at default. 4. A single point density measurement within the lower layer liquid in the tank. The measurement position is configured to 150mm below the middle interface at default 5. The value of this Average Density is based on the calculation after performing the Density Profile operation at the Proservo. 6. All of the selected number of density measured value from 1 ~ 16 points can be transmitted.

10

Endress+Hauser

Proservo NMS5

RS485 Modbus Module name No. of unit Baud rate Parity Cable Topology Transmission distance Instrument address Isolation Commdule RS 485 communication module (~2008), COM - 5 (2009~) Maximum 10 instruments per loop 600/1,200/ 2,400/ 4,800/ 9,600/ 19,200 bit/s, selectable Odd, Even, None, selectable Two wire twisted cable with screening (DGND is connected to the ground cable) Serial bus, electrically isolated, tree structure Maximum 1,200 m including limbs or branches (negligible with branches under 3 m) Accessed via touch control Bus inputs are electrically isolated from the other electronics

Bidirectional serial pulse (V1 protocol) Module name No. of units Baud rate Cable Topology Transmission distance Instrument address Isolation COM - 1 Maximum 10 instruments per loop 3,300 BPS Two wire (twisted pair) unscreened cable Serial bus, tree structure Maximum 6,000 m Accessed via touch control Serial communication circuit isolated from other circuits

HART Protocol Module name No. of units Baud rate Cable Transmission distance Instrument address Isolation Commdule HART (2009), COM - 6 (2009~) Maximum 15 instruments per loop 1,200 BPS Two wire, twisted pair screened cable Minimum core 0.15 (24AWG) Maximum 1,200 m Accessed via touch control Bus input are electrically isolated from the other electronics

Endress+Hauser

11

Proservo NMS5

Whessoematic 550 Module name No. of units Baud rate Cable Topology Transmission distance Instrument address Isolation WM550 communication module 15 instruments per loop (connected to RTU) 1,200 / 2,400 bit/s Two wire, twisted cable with screening 20 mA current loop Depending on specifications (ask your E+H engineer) Setting by DIP switches on communication board Current loop circuit isolated from other circuits

Mark / Space Module name No. of units Baud rate Cable Topology Transmission distance Instrument address Isolation Mark/Space communication module Depending on specification (ask to your E+H engineer) 1,200 / 2,400 / 4,800 / 9,600 / 19,200 bit/s Four wire Serial bus, tree structure Depending on specifications (ask your E+H engineer) Setting by DIP switches on communication board Serial pulse isolated from other circuits

Enraf Bi Phase Mark (BPM) Module name No. of units Baud rate Cable Topology Transmission distance Instrument address Isolation COM - 3 Maximum 10 instruments per loop 1,200, 2,400 bit/s, selectable Two wire, twisted cable with screening Serial bus, electrically isolated, tree structure Maximum 10 km Accessed via touch control Serial communication circuit isolated from other circuits

12

Endress+Hauser

Proservo NMS5

Analogue output Module name Output On alarm Electrical isolation Maximum load Load effect I/O - 5 4...20 mA, two channels freely assignable value Switchable Max.+110%, Min. -10% or hold last measured value Analogue output isolated from other circuits 500 ohm Negligible

Relay Module name Alarm output, Standard (Order Code position 050= 1,2,3 or 5) Hysteresis, Alarm output Operation output logic
Relay Condition Initial Configuration (normal status) On alarm On device Error On abnormal power supply (5% lower than, or 5% higher than specified power supply) Power outage Open Closed Closed Custody Transfer Closed Closed Open Open

I/O - 3 4 relays with potential-free change-over contacts, freely assignable to measured value Switch points and switching hysteresis freely adjustable, residual current fail-safe mode: minimum or maximum, selectable

Custody Transfer Open Hold last condition

Switching capacity, Alarm output

AC max. 250V, 2A / 62.5VA DC max. 220V, 2A / 60 W * FM and CSA approvals :AC 30V, 2A/DC 42V, 2A, 60W

Endress+Hauser

13

Proservo NMS5

Alarm output , Overspill prevention (Order Code position 050=4) Hysteresis, Alarm output Operation output logic

2 relays with potential- free changeover contacts, assignable to Level

Switch points and switching hysteresis freely adjustable, residual current fail-safe mode: minimum or maximum, selectable

Relay Condition Initial Configuration (normal status) On alarm On device Error On abnormal power supply (5% lower than, or 5% higher than specified power supply) Power outage
Switching capacity Umax. DC200V/AC200Vpp, 0.5A Imax. 0.5AC or peak AC Pmax. 15W/VA

Closed Open Open

Open

Open

Operation Input Operation output logic

2 photocouplers, for external input from controller (tumbler switch, DCS,etc.)

Gauge Status LEVEL UP STOP INTERFACE LEVEL

CTR1 0 (OFF) 1 (ON) 0 (OFF) 1 (ON)

CTR2 0 (OFF) 0 (OFF) 1 (ON) 1 (ON)

Input voltage Input current

15VDC, active circuit (supplied by Proservo) Approximately 5mA

14

Endress+Hauser

Proservo NMS5

Auxiliary energy
Electrical for Primary output
V1 Serial Pulse Modbus RS 485 HART Enraf BPM

(Order code position 60) is:

Refer to ordering Information

Endress+Hauser

15

Proservo NMS5

Whessoematic 550

and

16

Endress+Hauser

Proservo NMS5

Mark / Space

and

Endress+Hauser

17

Proservo NMS5

Cable entry

Thread : G , , NPT , , M20, 25 *TIIS : G only, CSA : NPT only High voltage type: 85 ... 264 VAC, 50/60 Hz Low voltage type: 20 ... 62 VDC / 20 ... 55 VAC 50/60Hz Caution! Allowable voltage supply is specifically stated depending on each Ex approval. Refer to the designated certification

Supply voltage

Power consumption Safe electrical isolation

Maximum 50 VA, 50W (cos j=0.5) Between power supply and signal output, CPU, RS 485, relay and other electronics

18

Endress+Hauser

Proservo NMS5

Performance characteristics
Maximum measured error Level Interface Density Sensitivity Motion delay timer

0.7mm ( 0.027 inch)*1 2.7 mm ( 0.106 inch)*2 0.005 g/cm3 *3 0.1 mm ( 0.004 inch)
Configurable in 20ms steps from 0 to 9.9 seconds

*1 : Under reference conditions *2 : Difference of product densities 100kg/m3(6.25 lb)/ft3 *3 : (optional) when calibrated and equipped for density measurement Compensation Displacer Automatic compensation of displacer weight Tank wall Compensation of depression and distortion

Endress+Hauser

19

Proservo NMS5

Operating conditions : Environment


Bus installation Modbus (RS485 Output) Termination Resistors Set terminators as required in specific enviroments. Bus Address Each transmitter has an individual bus address configured in the software of the transmitter. Bus Cabling The bus cabling is galvanically isolated from the transmitter and the PC plug-in board or the interface adapter. The screening must be grounded and have electrical continuity throughout. Bus Topology When planning the system, attention should be paid to the possible segmentation of the bus according to individual plant sections. Suitable topologies are: Tree of total length 1200 m Sakura V1 Serial Pulse Ouput The bus is connected to a RTU8, Tankvision or other Endress+Hauser V1- type receiver. The interface or receiver must be configured accordingly. Termination Resistors It is not necessary to set any termination resistors for serial pulse output. Bus Address
Each transmitter on a signal loop has an individual bus address. This is defined within the transmitter software.

Bus Cabling The bus cabling is electrically isolated from the transmitter and from the interface receiver. Standard communication cable (non-shielded twisted pair cable) can be used for the data transmission. Bus Topology The suitable topologies for the serial pulse output are: Serial max. 6000 m (Sakura V1) Tree of total length 6000 m. (Sakura V1)

20

Endress+Hauser

Proservo NMS5

Enraf Bi Phase Mark Output

The bus is connected to an Enraf I/F CIU or RTU8 to transmit measured value to upper host system as Entis (Enraf TG program) or Fuels Manager. These interface must be configured accordingly.

Termination Resistors It is not necessary to set any termination resistors for serial pulse output. Bus Address Each transmitter on a signal loop has an individual bus address. This is defined within the transmitter software. Bus Cabling The bus cabling is electrically isolated from the transmitter and from the interface receiver. Standard communication cable can be used for the data transmission. Bus Topology The suitable topologies for Enraf BPM serial pulse output are: Serial max. resistance: 400 ohm at 3 bus loops or less (10 transmitters per 1bus loop) Serial max. capacitance: 1 micro F or less Data transmission & Operation Proservo NMS5 is capable to transmit following sensory data as well as gauge operation command via Enraf BPM serial pulse output. Data: level, temperature, operation status Gauge command: STOP, UP, LEVEL, I/F

HART Output

The bus is connected to a HART master. The HART master must be configured accordingly. Bus Address Each transmitter on a signal loop has an individual bus address. This is defined within the transmitter software and / or auxiliary configuration environment such as host system or Field Communicator 375. Bus Cabling The bus cabling is galvanically isolated from the transmitter and the PC plug-in board or the interface adapter. The screening must be grounded and have electrical continuity throughout. EMC tests indicate the best result when the grounding at both ends and each transmitter is established. If there is a potential difference in between the grounds, measurement must be taken to equalize whilst observing a relevant hazardous area. Bus Topology The suitable topologies are: Serial max. 1000 m Tree of total length 1000 m.

Whessoematic 550 (WM 550) Output

The bus is normally connected to Whessoe 1098, RTU 8 or other upper host system via dual channel (can be single) WM550 current loop. Termination Resistors Admissible termination resistance should be calculated as follow. R = [Va - {n x (Vb + Vc)}] / 0.02 R = terminal resistance in the system n = number of transmitter in the system Va = max. available voltage at receiver Vb = voltage drop across transmitter Vc = voltage drop across receiver

Endress+Hauser

21

Proservo NMS5

Bus Address Each transmitter on a signal loop has an individual bus address. This is defined within the transmitter by mechanical dip switch on com board. Bus Cabling The bus cabling is galvanically isolated from the transmitter and the PC plug-in board or the interface adapter. BS5308 or equivalent 1.5sq.mm screened twisted pairs are recommended for bus cabling. Bus Topology The suitable topologies for the WM550 current output are depending on number of transmitter & cable quality on the loop. Recommended number of transmitter on single loop shall be less than 15 units to achieve the maximum performance. Varec Mark Space (M/S) Output The bus is normally connected to Interface Unit (IFU), Data acquisition Processor (DAP), RTU 8 or other upper host system via 4 wire M/S serial bus link. Termination Resistors Admissible termination resistance should be calculated as follow. R = (48 - 33) / {60mA + N (2.0mA)} R = terminal resistance in the system N = number of transmitter in the system 48 = supply voltage to receiver 33 = minimum M/S board operation voltage 60mA = required current for system operation 2.0mA = required current per transmitter Bus Address Each transmitter on a signal loop has an individual bus address. This is defined within the transmitter by mechanical dip switch on com board. Bus Cabling The bus cabling is galvanically isolated from the transmitter and the PC plug-in board or the interface adapter. The total length of field wiring shall be determined by calculation of maximum resistance within the system & required operation current. Once the total length is determined, distance has to be reduced by half because of current flow in both B+ & B- leads. Bus Topology The suitable topologies for the M/S serial pulse output are depending on number of transmitter & cable quality on the loop. Ambient temperature -20... +60oC -40... +60oC ( ATEX approval) -40... +60oC -200... +200oC IP 67 with closed housing and cable glands of equal protection type.... (ATEX/TIIS) NEMA 4X...(FM/CSA)

Storage temperature Liquid temperature Degree of protection

22

Endress+Hauser

Proservo NMS5

Operating condition : Process


Process pressure
Aluminum drum housing 0 19.8kPa 0 588kPa 0 2.45MPa
Maximum process pressur of JIS 10K/ANSI 300lbs/DIN DN80/JPI 300lbs :0.98MPa

Stainless drum housing NMS5-2 NMS5-5 NMS5-6

NMS5-1 NMS5-4

Measuring range

Level 28m 36m standard option standard option

Longer ranges available upon request . Please contact Endress+Hauser

Density 0.5000 to 2.0000 g/cm3

Endress+Hauser

23

Proservo NMS5

Mechanical construction
Design, dimensions

NMS5 - 1 NMS5 - 4

40

NMS5 - 2 NMS5 - 5 NMS5 - 6

40

Housing materials of Construction

Electrical compartment : aluminium casting Drum chamber for NMS 5-1/5-4 : aluminium casting Drum chamber for NMS 5-2/5-5/5-6 : stainless steel 316 casting NMS 5-1/5-4 : 12 kg NMS 5-2/5-5/5-6 : 27 kg ANSI, JIS, DIN 3" and 6" (standard) or equivalent. Refer to order code for full selection.

Weight

Flange type Measuring wire

Material (standard)

Stainless steel 316, 0.15 mm (standard) AlloyC. 0.2 mm (max. 16 m range) PFA coated St/St 316L, 0.4 mm (max. 16m range)

Note! When liquid level in a tank becomes turbulent condition,use stilling well pipe or guide wire for installation.

24

Endress+Hauser

Proservo NMS5

Displacer Diameter Material (standard) Material (optional) Horizontal movement 50 mm (Standard), 30...110mm (optional) Stainless steel 316 AlloyC, PTFE 28 m (AISI316) :1.23 mm / m with standard 0.15mm wire 36 m (AISI316): 1.1 mm / m with standard 0.15mm wire 16 m (AISI316): 2.17mm /m with PFA covered wire 16 m (Alloy C): 1.73mm/m 0...2500 mm / min...maximum

Traveling speed

Cable entry

Endress+Hauser

25

Proservo NMS5

Human interface
Operating concept Proservo NMS5 is furnished with a four line illuminated liquid crystal display. With the E+H matrix driven operation, configuration is simple. Using only three keys, all parameters can be selected and modified. For example: Operation - level; interface; spot & profile density, water dip, & tank bottom Current output Relay output Maintenance prediction Calibration, etc. The display can be configured to be displayed in English, Japanese or Chinese. Measurement unit & decimal point can be also configured within NMS matrix. Operational Security The programming information can be protected by software access codes that disable all programmable parameters or by a hardware switch to prevent changes from remote transmission or the touch control keypad. A self-diagnosis function checks for any operational failures.

Display(LCD)

IIluminated LCD

Infrared transmitting diaode

Infrared receiving diaode 3 optical operating elements " Touch control "

Four line 16-digit illuminated display English, Japanese, Chinese selectable Programming Memo function Three optical keys (touch control) for selection of matrix functions. Memo of maintenance information.

26

Endress+Hauser

Proservo NMS5

Advanced Maintenance
Maintenance Prediction Proservo NMS 5 will provide advance warning of required maintenance such as replacement of worn wire etc. The operating life-span of electrical and mechanical parts of the Proservo NMS 5 are factory set within the instruments memory. This information is checked involving with the built-in clock and compared and registered in the instrument. The maintenance record can be accessed via the matrix and will provide information of alarm data (e.g. date, time, alarm type). A memo function allows the user or an E+H Service Engineer to enter maintenance data manually. Proactive safety diagnostic function warns of mechanical failure, and outputs maximum level value, e.g. 99999 to local display and fieldbus.

Maintenance

Proactive Safety

Endress+Hauser

27

Proservo NMS5

Certificates and Approval


Ex approvals ATEX II 1/2G Ex d IIB T4, T3 II 1/2G Ex d[ia] IIB T4, T3 II 1/2G Ex d IIC T4, T3 II 1/2G Ex d IIB T4, T3 , -40C II 1/2G Ex d[ia] IIB T4, T3 , -40C IEC Ex d [ia] IIB T4, T3 Ga/Gb Ex d IIB T4, T3 Ga/Gb Ex d IIC T4, T3 Ga/Gb Ex d [ia] IIB T4, T3 Ga/Gb, -40C Ex d IIB T4, T3 Ga/Gb, -40C TIIS Ex d IIB T4 FM XP - AIS Cl. I, Div. I, Gr. C - D XP Cl. I, Div. I, Gr. C - D CSA Ex d [ia] Cl. I, Giv.1, Gr. C - D Cl. I, Giv.1, Gr. C - D Custody transfer approvals PTB: Germany NMi: Netherlands TV: Germany TV: Germany EMC-Directive 89/336/EC PE-Directive 97/23/EC EN 10204-3.1B OIML-R85/1998 OIML-R85/2008 SIL IEC61508, IEC61511 ISO 9001:2008

Overspill prevention SIL External standards and guidelines

28

Endress+Hauser

Proservo NMS5

Ordering information
Proservo NMS5
010 Drum Housing Pressure Rating; Material: 1 0...200mbar/20kPa/2.9psi ; Alu. 2 0...200mbar/20kPa/2.9psi ; Stainless steel 4 0...5.88bar/588kPa/85.28psi ; Alu. 5 0...5.88bar/588kPa/85.28psi ; Stainless steel 6 0...24.5bar/2.45MPa/355.34psi ; Stainless steel 9 Special version, TSP-no. to be spec. Approval: 0 Weather proof, IP 67 NEMA 4X 1 TIIS Ex d IIB T4 5 FM XP Cl. I Div. 1 Gr. C-D N FM XP-AIS Cl. I Div.1 Gr. C-D 6 CSA Cl. I Div. 1 Gr. C-D O CSA Ex d[ia] Cl. I Div. 1 Gr. C-D G ATEX II 1/2G Ex d IIB T4, T3 Q ATEX II 1/2G Ex d IIC T4, T3 S ATEX II 1/2G Ex d IIB T4, T3 ,-40 J ATEX II 1/2G Ex d[ia] IIB T4, T3 U ATEX II 1/2G Ex d[ia] IIB T4, T3 -40C A IEC Ex d [ia] IIB T4, T3 Ga/Gb B IEC Ex d IIB T4, T3 Ga/Gb C IEC Ex d IIC T4, T3 Ga/Gb D IEC Ex d [ia] IIB T4, T3 Ga/Gb, -40C E IEC Ex d IIB T4, T3 Ga/Gb, -40C 9 Special version, TSP-no. to be spec. Application: A Liquid Level B PTB (<1mm) type approval, liquid level C NMi (<1mm) type approval, liquid level D Multi measurement, liquid level, I/F level, Bottom, Density E PTB (<1mm) type approval, liquid level, I/F level, Bottom, Density F NMi (<1mm) type approval, liquid level, I/F level, Bottom, Density G Density profile multi measurement, liquid level, I/F level, Bottom, Density H PTB (<1mm) type approval, density profile, liquid level , I/F level, Bottom, Density J NMi (<1mm) type approval, density profile, liquid level , I/F level, Bottom, Density Y 040 Special version, TSP-no. to be spec. Output 1: F Not selected A 2-way 2-wire (V1 protocol) J 2-way 2-wire (MDP protocol) B 2-way 2-wire (BBB protocol) C 2-way 2-wire (MIC, RS232C protocol) D 2-way 2-wire (MIC protocol) G 4-20mA HART active H 4-20mA HART passive L Whessmatic 550, overvoltage protection M Mark Space N Enraf BPM P Modbus RS 485 Q *2 x Modbus, current loop Y Special version, TSP-no. to be spec. Output 2: 0 Not selected 1 4 x relay SPST 2 2 x 4-20mA 3 4 x relay SPST, 2 x 4 - 20mA 4 2 x relay SPST, Overspill prevention TV 5 4 x relay SPST, 1 x 4 - 20mA 9 Special version, TSP-no. to be spec.

020

030

050

NMS5-

Product designation (part 1)

Endress+Hauser

29

Proservo NMS5

060

Input: 0 HART ( NMT5xx, NRF560, pressure transmitter) 1 1 x spot temperature Pt100, HART (NMT5xx, NRF560, pressure transmitter) 2 2 x operation contact, HART (NMT5xx, NRF560, pressure transmitter) 3 1 x spot temperature Pt100, 2 x operation contact, HART (NMT5xx, NRF560, pressure transmitter) 4 1 x status, HART (NMT5xx, NRF560, pressure transmitter) 5 1 x spot temperature Pt100, 1 x status, HART (NMT5xx, NRF560, pressure transmitter) 6 1 x spot temperature Pt100, 1 x status, 2 x operation contact, HART (NMT5xx, NRF560, pressure transmitter) 9 Special version, TSP-no. to be spec. Measuring Range; wire: C 0 - 28m; SUS316, 0.15mm, L 0 - 36m; SUS316, 0.15mm, N *0-47m; SUS316, 0.15mm H 0 - 16m; PFA>SUS316, 0.4mm K 0 - 16m; Alloy C, 0.2mm M 0 - 22m; Alloy C, 0.2mm Y Special version, TSP-no. to be spec. Cable entry: E 4 x thread G1/2 F 4 x thread G3/4 G 4 x thread NPT1/2 H 4 x thread NPT3/4 L 4 x thread M20 M 4 x thread M25 Y Special version, TSP-no. to be spec. Process connection: A 10K 80A RF, flange JIS B2220 C 10K 80A FF, flangeJIS B2220 U 10K 150A RF, flangeJIS B2220 B *10K 150A FF, flangeJIS B2220 E 20K 80A RF, flangeJIS B2220 F *20K 100A RF, flangeJIS B2220 G 3" 150Ibs RF, flange JIS B2220 J 3" 300lbs RF (apply for NMS5-6),flange ANSI B16.5 W *4" 300lbs RF (apply for NMS5-6), flange ANSI B16.5 T 6" 150lbs RF, flange ANSI B16.5 L DN80 PN10 B1, flange EN1092-1 (DIN2527 B) N DN80 PN25 B1, flangeEN1092-1 (DIN2527 B) Q 80A 150lbs RF, flange JPI 7S-15 S 80A 300lbs RF (apply for NMS5-6), flange JPI 7S-15 R *150A 300lbs RF, flange JPI 7S-15 Y Special version, TSP-no. to be spec. Power supply: 3 85 - 264 VAC, 50/60 Hz 4 20 - 62 VDC, 20 - 55 VAC, 50/60 Hz 9 Special version, TSP-no. to be spec. Displacer: B Conical 50 mm, PTFE D Cylindrical 50 mm, SUS316 K Cylindrical 40 mm, SUS316 N Cylindrical 30 mm, SUS316 R Conical 70 mm, SUS316 S Conical 110 mm, SUS316 T Cylindrical 50 mm, AIloy C U Cylindrical 50 mm, PTFE V Cylindrical 40 mm, PTFE W Cylindrical 30 mm, PTFE Y Special version, TSP-no. to be spec.

070

080

090

100

110

NMS5-

Product designation (part 2)

30

Endress+Hauser

Proservo NMS5

120

O-ring; chamber finishing: 0 NBR ; not selected 1 Silicon rubber ; not selected 5 Silicone rubber ; FEP coated 3 PTFE (wire drum FKM) ; not selected 4 PTFE (Wire drum FKM) ; FEP coated 2 FKM ; not selected 7 FKM ; FEP coated 6 CR ; not selected 8 FFKM ; not selected A FFKM ; FEP coated 9 Special version, TSP-no. to be spec. Options: A not selected C Rc3/8 cleaning nozzle D Rc3/8 gas purging nozzle E Guide wire installation G Relief valve H Relief valve, pressure gauge J Sunshade L Rc3/8 gas purging nozzle, sunshade M Rc3/8 cleaning nozzle, sunshade N Rc3/8 gas purging nozzle, guide wire installation P Rc3/8 cleaning nozzle, guide wire installation Q Guide wire installation, sunshade R Relief valve, guide wire installation S Relief valve, pressure gauge, guide wire installation T Relief valve, sunshade U Relief valve, pressure gauge, sunshade Y Special version, TSP-no. to be spec. Complete product designation

130

NMS5-

Endress+Hauser

31

Proservo NMS5

Accessories
Calibration Chamber
CALIBRATION CHAMBER

8 hole

Flange 172

300 Flange

150

Calibration chamber is recommended for use with tank level gauges in order to allow maintenance (removing displacers), while tank is in service. Standard chamber is 6" flange, with bolts & packing for NMS connection. Note! The dimensions differ depending on material, flange size. Please contact Endress+Hauaser for details. NHC4HP (high pressure version)
10 Process Connection: A 10K 150A RF, flange JIS B2220 C 10K 150A FF, flange JIS B2220 E 20K 150A RF, flange JIS B2220 G 6" 150lbs RF, flange ANSI B16.5 J 6" 300lbs RF, flange ANSI B16.5 L DIN 150 PN10 B1, flange EN1092-1(DIN2527 B)? N DIN 150 PN25 B1, flange EN1092-1(DIN2527 B) Q 150A 150lbs RF, flange JPI 7S-15 S 150A 300lbs RF, flange JPI 7S-15 Y Special version, TSP-no. to be spec. Pipe Material; Flange Material: 2 STPG370 ; SS400 3 SUS304TP; SUS304 9 Special version, TSP-no. to be spec. Bolts, Packing: 0 not used 1 SUS304, Valker #6502 9 Special version, TSP-no. to be spec. Pressure Gauge, Relief Valve: 1 Selected 9 Special version, TSP-no. to be spec. Complete product designation

20

30

40

NHC4HP-

32

Endress+Hauser

Proservo NMS5

NHC4LP (low pressure version)


010 Process Connection: A 10K 150A RF, flange JIS B2220 C 10K 150A FF, flange JIS B2220 G 6" 150lbs RF, flange ANSI B16.5 L DN150 PN10 B1, flange EN1092-1(DIN2527 B) Q 150A 150lbs RF, flange JPI 7S-15 Y Special version, TSP-no. to be spec. Pipe Material; Flange Material: 1 AC4AAC4A 3 9 030 SUS304TPSUS304 Special version, TSP-no. to be spec. Bolts, Packing: 0 not used 1 SUS304 , Valker #6502 9 Special version, TSP-no. to be spec. Complete product designation

020

NHC4LP-

Endress+Hauser

33

Proservo NMS5

Power+Control Switch
Power + Control Swith
SPECIFICATIONS RATED VOLTAGE RATED CURRENT HOUSING TERMINAL BOX STRUCTURE NO.OF CERTIFICATE AC110 / 220V 6A / 5A ALLMINIUM ALLY CASTING IRON CASTING EXPLOSION PROOF d3aG5 T3875
Grounding 65 113
2 - 7 STOP OFF INST LIFT

120

CONNECTION DIAGRAM NHS8 Term.No 1 2 3 4 5 6 7 16 COM 17 CRT1 18 CRT2 Power Supply NMS Term.No 1 2 Power L Power N
193

Handle position

Wiring
INST OFF LIFT STOP 7

INST STOP LIFT OFF

Cable entry
5 2 1

6 4 3

Cable Entry PF (G)1/2 PF (G) 3/4 PF (G)1

h (mm) 17 20 24

h
B 140 140 145

Power & Control Switch is used for tank gauges field mounted, for tank gauges. It provides additional switching of operation contacts of the gauge in order to control the gauges operation such as lift up displacer. NHS8
010 Approval: 1 Weather proof IP67 2 Flame proof (JIS d3aG5) Cable entry: 0 2 x thread G3/4 1 2 x thread G1 2 2 x thread NPT3/4 3 2 x thread NPT1 9 Special version, TSP-no. to be spec. Complete product designation

020

NHS8-

34

Endress+Hauser

Proservo NMS5

Ball Valve

Body cap

Ball

Body
Ball valve is recommended for use with tank level gauges in order to allow maintenance such as removing displacers, while tank is in service. Standard ball valve with ANSI flanges. Ball material is SS304, seat material is PTFE. Note! The dimensions differ depending on material, flange size. Please contact Endress+Hauser for details.

NHV4A (ANSI flanges) Standard ball valve with ANSI flanges. Ball material is SS304, seat material is PTFE.
10 Process Connection ; Body: C31 3" 150lbs RF ; Steel casting flange ANSI B16.5 C33 3" 300lbs RF ; Steel casting flange ANSI B16.5 C61 6" 150lbs RF ; Steel casting flange ANSI B16.5 C63 6" 300lbs RF ; Steel casting flange ANSI B16.5 S31 3" 150lbs RF ; SS304 flange ANSI B16.5 S33 3" 300lbs RF ; SS304 flange ANSI B16.5 S61 6" 150lbs RF ; SS304 flange ANSI B16.5 S63 6" 300lbs RF ; SS304 flange ANSI B16.5 Y99 Special version, TSP-no. to be spec. Ball Type: A Full bore B Reduced bore Y Special version, TSP-no. to be spec. Complete product designation

20

NHV4A-

Endress+Hauser

35

Proservo NMS5

NHV4J (JIS flanges) For body in mild steel and in SS304, ball material is SS304, ball material is SS304. For body in SS316, ball material is SS316. Seal material is PTFE.
10 Process Connection ; Body: C11 10K 80A RF ; Steel flange JIS B2220 C12 10K 150A RF ; Steel flange JIS B2220 C21 20K 80A RF ; Steel flange JIS B2220 C22 20K 150A RF ; Steel flange JIS B2220 S11 10K 80A RF ; SUS316 flange JIS B2220 S12 10K 150A RF ; SUS316 flange JIS B2220 S21 20K 80A RF ; SUS316 flange JIS B2220 S22 20K 150A RF ;SUS316 flange JIS B2220 H11 10K 80A RF ; SUS304 flange JIS B2220 H12 10K 150A RF ; SUS304 flange JIS B2220 H21 20K 80A RF ; SUS304 flange JIS B2220 H22 20K 150A RF ;SUS304 flange JIS B2220 Y99 Special version, TSP-no. to be spec. Ball Type: A Full bore B Reduced bore Y special version, TSP-no. to be spec. Complete product designation

20

NHV4J-

36

Endress+Hauser

Proservo NMS5

Reducing Flange
Low pressure (JPI example) High pressure (ANSI example)

Stud Bolt Flange

Stud Bolt Flange

Please use Reducing Flange when Proservo connection 80A(30")and mounting nozzle for customer is 150A(6"). NHF4
10 Process Connection ; Body: A 10K 150A RF, flange JIS B2220 C 10K 150A FF, flange JIS B2220 E 20K 150A RF, flange JIS B2220 G 6" 150lbs RF, flange ANSI B16.5 J 6" 300lbs RF, flange ANSI B16.5 L DIN 150 PN10 B1, f lange EN1092 (DIN2527 B) N DIN 150 PN25 B1, flange EN1092 (DIN2527 B) Q 150A 150lbs RF, flange JPI 7S-15 S 150A 300lbs RF, flange JPI 7S-15F Y Special version, TSP-no. to be spec. Flange Material: 0 Mild steel (JIS SS41) 1 SUS304 9 Special version, TSP-no. to be spec. Complete product designation

20

NHF4-

Note! NHF4 is not required if Proservo is ordered with "Ordering Information ; Guide Wire Installation (130-E)". When ordered as NMS5-xxxxxxxxxxxxE with Guide Wire Installation, all the required mounting equipment is included.

Endress+Hauser

37

Proservo NMS5

Supplementary Documentation
Technical Information TI00042G Technical Information Prothermo NMT 539 TI 008N Technical Information Promonitor NRF 560 Operating Manual BA00401G Operating Manual Proservo NMS5 KA001N Compact Instruction Whessoemtric 550 KA002N Compact Instruction RS485 Modbus Safety Instructions XA00578G-A Proservo NMS5 - ATEX XA00582G-A Proservo NMS5 - IECEx Functional Safety Manual SD00337G Proservo NMS5 - (4-20mA Output, Overspill prevention)

Compact Instructions

38

Endress+Hauser

Proservo NMS5

Appendix
Stainless Steel conversion table The stainless steel material used in products of Endress + Hauser Yamanashi normally have expressions according to Japanese industrial standards, such as JIS. Each country or region may have different expressions place to place. The following conversion table contains the expression of equivalent stainless steel material based on the chemical composition and mechanical properties.

Country Japan Germany

Standard JIS DIN 17006 W.N. 17007 SUS304 X5 CrNi 18 10 X5 CrNi 18 12 1.4301 1.4303 Z 6 CN 18-09 X5 CrNi 1810 304S15 / 304S16 304 X6 CrNi 1810 X6 CrNi 19-10 08KH18N10 06KH18N11 11 S30400 SUS304L X2 CrNi 18 11 1.4306 Z 2CN 18-10 X2 CrNi 1911 304S11 304 L X3 CrNi 1810 X2 CrNi 19-10 03KH18N11 10 S30403

Expressions SUS316 X5 CrNiMo 17 12 2 / 1713 3 1.4401 / 1.4436 Z 6 CND 17-11 / 17 12 X5 CrNiMo 1712 / 1713 316S31 / 316S33 316 X6 CrNiMo 17 12 2 / 17 13 3 X6 CrNiMo 17-12-03 _ 20 S31600 SUS316L X2 CrNiMo 17 13 2 1.4404 Z2 CND 17-12 X2 CrNiMo 1712 316S11 316L X3 CrNiMo 17 12 2 X2 CrNiMo 17-1203 03KH17N14M2 19 S31603

France Italy U.K. U.S.A. U.E. Spain Russia -

AFNOR UNI BSI AISI EURONORM UNE GOST ISO ASME

Note! Since each standard carries its own mechanical and scientific definition, some expressions may not have the straight conversion from the Japanese standard. Consult with the local authority or legislature to ensure the proper comparison of the applied standard prior to determining specification.

Endress+Hauser

39

Proservo NMS5

Endress + Hauser Yamanashi Co., Ltd. 862-1 Mitsukunugi Sakaigawa-cho Fuefuki-shi Yamanashi, 406-0846 Japan Phone: ++81 55 266 4964 Fax: ++81 55 266 4969 http://www.endress.com

TI 00452G/08/EN/02.11 71136221 FM+SGML 8.0