Escolar Documentos
Profissional Documentos
Cultura Documentos
http://127.0.0.1:52199/hedex/pages/31183950/02%20(2009-10-30)/311...
Note
None.
Parameter
Parameter ID CellId Parameter Name Cell ID Parameter Description Meaning: This parameter uniquely identifies a cell. GUI Value Range: 0~65535 Actual Value Range: 0~65535 Unit: None Default Value: None Recommended Value: None Meaning: This parameter specifies the maximum number of inter-RAT RAB directed retries. It decides the size of the candidate set for inter-RAT DRD. The value 0 indicates that inter-RAT RAB DRD is not applicable. This parameter can be cell-oriented. GUI Value Range: 0~5 Actual Value Range: 0~5 Unit: None Default Value: None Recommended Value: 2 Meaning: This parameter specifies whether the service differential DRD algorithm will be applied. - ON: The service differential DRD algorithm will be applied. - OFF: The service differential DRD algorithm will not be applied. GUI Value Range: ON, OFF Actual Value Range: ON, OFF Unit: None Default Value: None Recommended Value: OFF
DRMaxGSMNum
ServiceDiffDrdSwitch
1 of 6
8/19/2010 11:29 PM
http://127.0.0.1:52199/hedex/pages/31183950/02%20(2009-10-30)/311...
Parameter ID LdbDRDSwitchDCH
Parameter Description Meaning: This parameter specifies whether the load balancing DRD algorithm will be applied for DCH services. - ON: The load balancing DRD algorithm will be applied. - OFF: The load balancing DRD algorithm will not be applied. GUI Value Range: ON, OFF Actual Value Range: ON, OFF Unit: None Default Value: None Recommended Value: OFF Meaning: This parameter specifies whether the load balancing DRD algorithm will be applied for HSDPA services. - ON: The load balancing DRD algorithm will be applied. - OFF: The load balancing DRD algorithm will not be applied. GUI Value Range: ON, OFF Actual Value Range: ON, OFF Unit: None Default Value: None Recommended Value: OFF Meaning: This parameter specifies which choice the load balancing DRD algorithm will be applied. - Power: Power(Downlink none-HSDPA power is used for DCH services, and downlink HSDPA guarantee power is used for HSDPA services) will be applied to the load balancing DRD algorithm. - UserNumber: User number(Downlink R99 equivalent user number is used for DCH services, and downlink HSDPA user number is used for HSDPA services) will be applied to the the load balancing DRD algorithm. GUI Value Range: Power, UserNumber Actual Value Range: Power, UserNumber Unit: None Default Value: None Recommended Value: UserNumber Meaning: This parameter specifies the downlink load threshold to trigger load balancing DRD for DCH services. The load balancing DRD will probably be triggered only when the downlink remanent non H power or remanent R99 equivalent user number of the cell is less than this threshold. GUI Value Range: 0~100 Actual Value Range: 0~100 Unit: per cent Default Value: None Recommended Value: 35
LdbDRDSwitchHSDPA
LdbDRDchoice
LdbDRDLoadRemainThdDCH
2 of 6
8/19/2010 11:29 PM
http://127.0.0.1:52199/hedex/pages/31183950/02%20(2009-10-30)/311...
Parameter ID
Parameter Name
Parameter Description Meaning: This parameter specifies the downlink load threshold to trigger load balancing DRD for HSDPA services. The load balancing DRD will probably be triggered only when the downlink remanent HSDPA guarantee power or remanent HSDPA user number of the cell is less than this threshold. GUI Value Range: 0~100 Actual Value Range: 0~100 Unit: per cent Default Value: None Recommended Value: 100 Meaning: This parameter specifies whether the code balancing DRD algorithm will be applied. - ON: The code balancing DRD algorithm will be applied. - OFF: The code balancing DRD algorithm will not be applied.The DR_RAB_SING_DRD_SWITCH in SET UCORRMALGOSWITCH should be enable.If it is combination service,the DR_RAB_COMB_DRD_SWITCH should be enable. GUI Value Range: ON, OFF Actual Value Range: ON, OFF Unit: None Default Value: None Recommended Value: OFF Meaning: This parameter specifies one of the triggering conditions of code balancing DRD. (The other condition is the code occupancy.) This condition refers to that the minimum spreading factor of the best cell is not smaller than the value of this parameter. GUI Value Range: SF4, SF8, SF16, SF32, SF64, SF128, SF256 Actual Value Range: SF4, SF8, SF16, SF32, SF64, SF128, SF256 Unit: None Default Value: None Recommended Value: SF8 Meaning: This parameter specifies one of the triggering conditions of code balancing DRD. (The other condition is the minimum spreading factor.) This condition refers to that the code occupancy in the best cell is not lower than the value of this parameter. GUI Value Range: 0~100 Actual Value Range: 0~100 Unit: per cent Default Value: None Recommended Value: 13
CodeBalancingDrdSwitch
CodeBalancingDrdMinSFThd
3 of 6
8/19/2010 11:29 PM
http://127.0.0.1:52199/hedex/pages/31183950/02%20(2009-10-30)/311...
Parameter ID ReDirBandInd
Parameter Description Meaning: This parameter specifies the target frequency band in the redirection process. GUI Value Range: Band1, Band2, Band3, Band4, Band5, Band6, Band7, Band8, Band9, DependOnNCell, BandIndNotUsed Actual Value Range: Band1, Band2, Band3, Band4, Band5, Band6, Band7, Band8, Band9, DependOnNCell, BandIndNotUsed Unit: None Default Value: None Recommended Value: DependOnNCell Meaning: This parameter specifies whether the UL frequency of the target cell of redirection needs to be configured. - TRUE: The UL frequency needs to be configured. - FALSE: The UL frequency does not need to be configured. It is configured automatically according to the relationship between UL and DL frequencies. GUI Value Range: TRUE, FALSE Actual Value Range: TRUE, FALSE Unit: None Default Value: None Recommended Value: None Meaning: This parameter specifies the target uplink UARFCN of a cell for RRC redirection. Depending on the band indication, the value range as shown below: Band1: Common frequencies: [9612-9888] Special frequencies: none Band2: Common frequencies: [9262-9538] Special frequencies: {12, 37, 62, 87, 112, 137, 162, 187, 212, 237, 262, 287} Band3: Common frequencies: [937-1288] Special frequencies: none Band4: Common frequencies: [1312-1513] Special frequencies: {1662, 1687, 1712, 1737, 1762, 1787, 1812, 1837, 1862} Band5: Common frequencies: [4132-4233] Special frequencies: {782, 787, 807, 812, 837, 862} Band6: Common frequencies: [4162-4188] Special frequencies: {812, 837}
ReDirUARFCNUplinkInd
ReDirUARFCNUplink
4 of 6
8/19/2010 11:29 PM
http://127.0.0.1:52199/hedex/pages/31183950/02%20(2009-10-30)/311...
Parameter ID
Parameter Name
Parameter Description Band7: Common frequencies: [2012-2338] Special frequencies: {2362, 2387, 2412, 2437, 2462, 2487, 2512, 2537, 2562, 2587, 2612, 2637, 2662, 2687} Band8: Common frequencies: [2712-2863] Special frequencies: none Band9: Common frequencies: [8762-8912] Special frequencies: none BandIndNotUsed: [0-16383] Assume that the target uplink UARFCN for RRC redirection is unspecified, the band indication is Band1, Band2, Band3, Band4, Band5, Band6, Band7, Band8, or Band9, and the target downlink UARFCN for RRC redirection is valid. Then, the default uplink UARFCN is as follows: -If the DL frequency belongs to common frequencies, then Band1: Uplink UARFCN = Downlink UARFCN - 950 Band2: Uplink UARFCN = Downlink UARFCN - 400 Band3: Uplink UARFCN = Downlink UARFCN - 225 Band4: Uplink UARFCN = Downlink UARFCN - 225 Band5: Uplink UARFCN = Downlink UARFCN - 225 Band6: Uplink UARFCN = Downlink UARFCN - 225 Band7: Uplink UARFCN = Downlink UARFCN - 225 Band8: Uplink UARFCN = Downlink UARFCN - 225 Band9: Uplink UARFCN = Downlink UARFCN - 475 -If the DL frequency belongs to special frequencies, then Band2: Uplink UARFCN = Downlink UARFCN - 400 Band4: Uplink UARFCN = Downlink UARFCN - 225 Band5: Uplink UARFCN = Downlink UARFCN - 225 Band6: Uplink UARFCN = Downlink UARFCN - 225 Band7: Uplink UARFCN = Downlink UARFCN - 225 GUI Value Range: 0~16383 Actual Value Range: 0~16383 Unit: None Default Value: None Recommended Value: None
ReDirUARFCNDownlink
Meaning: This parameter specifies the target downlink UARFCN of a cell for RRC redirection. GUI Value Range: 0~16383 Actual Value Range: 0~16383 Unit: None Default Value: None Recommended Value: None
5 of 6
8/19/2010 11:29 PM
http://127.0.0.1:52199/hedex/pages/31183950/02%20(2009-10-30)/311...
Example
Open the load balance DRD switch for DCH users of cell 1: MOD UCELLDRD: CellId=1, LdbDRDSwitchDCH=ON;
6 of 6
8/19/2010 11:29 PM