MV Technology Solutions is supplier of a diverse range of high quality products throughout the Asia Pacific region to Power, Railway, Heavy Industry & Mining Customers. Our exceptional service along with high quality brands name products from world leading companies around the globe. These world leading brands and our high level of customer service and technical expertise ensure our customer requirements are seen to on every occasion. Our Product Portfolio includes: POWER AND TRANSMISSION PRODUCTS Cable Accessories & Terminations Fault Circuit Indicators H.V. Fuses & Fuse Assembly Tester Integrated Voltage Indication Systems Insulators & Line Hardware Accessories LV Accessories MV Switching & Components Motor Operating Devices Remote and Area Lighting Safety Products Solvents & Lubricants Surge Protection Testers and Testing Sticks OEM SWITCHGEAR COMPONENTS 11 to 33kV Cable Access. & Terminations DIN H.V. Fuses & Fuse Assembly Tester Indoor Air Insulated Disconnectors Indoor Air Insulated Switches Indoor Air Insulated Earth Switches Indoor Vacuum Circuit Breakers Indoor Vacuum Contactors Integrated Voltage Indication Systems Motor Operating Devices RAIL ROLLING STOCK PRODUCTS Speed Measuring & Data Acquisition Surge Protection for Rolling Stock Specialised Railway Testers
Contents
Voltage
11 kV
Product Group
Longrod Insulator
Page
3
22 kV
Longrod Insulator
22 kV
Longrod Insulator
33 kV
Longrod Insulator
SP-AusNet Approved.
6-7
33kV
Longrod Insulator
Energy Australia
33 kV
Longrod Insulator
Energex Approved
33 kV
Longrod Insulator
10-11
66 kV
Longrod Insulator
SP-AusNet Approved
12-14
66kV
Longrod Insulator
15
66 kV
Longrod Insulator
16
132 kV
Longrod Insulator
Energex Approved
17-18
66 kV
132 kV
Drawing number One minute power frequency withstand voltage, 50Hz, wet Lightning impulse withstand voltage, 1,2/50, pos. Arcing distance Minimum creepage distance Specified mechanical load (SML) Routine test load (RTL) Number of sheds Weight (approx.) Clevis in acc. to IEC 60471 (16L) Tongue in acc. to IEC 60471 (16L) SML and RTL are in acc. to IEC 61109 Material Data: Insulator End Fitting Cotter Pin
E-CR Glassfibre rod with HTV Silicone Rubber Housing Steel Cast or Machined - Hot Dip Galv. acc. to EN ISO 1461 Stainless Steel
3 | Page
Drawing number One minute power frequency withstand voltage, 50Hz, wet Lightning impulse withstand voltage, (1,2/50, pos.) Arcing distance Minimum creepage distance Specified mechanical load (SML) Routine test load (RTL) Number of sheds Weight (approx.) Tongue in acc. to IEC 60471 Clevis in acc. to IEC 60471 SML to RTL are in acc. to IEC 61109 Galvanizing (h.d.g.) acc. to EN ISO 1461 Material Data: Insulator End Fittings
E-CR Glassfibre rod with HTV Silicone Rubber Housing Steel Machined Hot Dip Galv. acc. to EN ISO 1461 Stainless Steel
Cotter Pin
4| Page
Drawing number One minute power frequency withstand voltage, 50Hz, wet Lightning impulse withstand voltage, 1,2/50, pos. Minimum Arcing distance Minimum creepage distance Specified mechanical load (SML) Routine test load (RTL) Number of sheds Mass(approx.) Ball in acc. to IEC 60120(16) Socket in acc. to IEC 60120(16A) SML and RTL are in acc. to IEC 61109 Material Data: Insulator End Fitting Cotter Pin
E-CR Glassfibre rod with HTV Silicone Rubber Housing Steel (Cast or Machined) - Hot Dip Galv. acc. to EN ISO 1461 Stainless Steel
5 | Page
Drawing number One minute power frequency withstand voltage, 50Hz, wet Lightning impulse withstand voltage, (1,2/50, pos.) Minimum Arcing distance Minimum creepage distance Specified mechanical load (SML) Routine test load (RTL) Number of sheds Mass (approx.) Clevis in acc. to IEC 60471 (16L) Tongue in acc. to IEC 60471 (16 L) SML to RTL are in acc. to IEC 61109 Material Data: Insulator End Fittings Humpback Split Pin
E-CR Glassfibre rod with HTV Silicone Rubber Housing Steel Machined Hot Dip Galv. acc. to EN ISO 1461 Stainless Steel
6 | Page
Drawing number One minute power frequency withstand voltage, 50Hz, wet Lightning impulse withstand voltage, (1,2/50, pos.) Minimum Arcing distance Minimum creepage distance Specified mechanical load (SML) Routine test load (RTL) Number of sheds Mass (approx.) Ball in acc. to IEC 60120 (16) Socket in acc. to IEC 60120 (16A) SML to RTL are in acc. to IEC 61109 SML and RTL are in acc. to IEC61109 Material Data: Insulator End Fittings Cotter Pin
E-CR Glassfibre rod with HTV Silicone Rubber Housing Steel Hot Dip Galv. Acc. to EN ISO 1461 Stainless steel
7 | Page
Drawing number One minute power frequency withstand voltage, 50Hz, wet Lightning impulse withstand voltage, (1,2/50, pos.) Arcing distance Minimum creepage distance Specified mechanical load (SML) Routine test load (RTL) Number of sheds (small/large) Material of fittings Weight (approx.) Ball in acc. to IEC 60120(16) Socket in acc. to IEC 60120 (16A) SML and RTL are in acc. to IEC 61109 Galvanizing (h.d.g.) acc. to EN ISO 1461
8 | Page
Drawing number One minute power frequency withstand voltage, 50Hz, wet Lightning impulse withstand voltage, (1,2/50, pos.) Minimum Arcing distance Minimum creepage distance Specified mechanical load (SML) Routine test load (RTL) Number of sheds (small/large) Mass (approx.) Clevis in acc. to IEC 60471 (16L) Tongue in acc. to IEC 60471 (16L) SML and RTL are in acc. to IEC 61109 Material Data: Insulator End Fittings Humpback Split Pin
E-CR Glassfibre rod with HTV Silicone Rubber Housing Steel Hot Dip Galv. Acc. to EN ISO 1461 Stainless steel
9 | Page
Drawing number One minute power frequency withstand voltage, 50Hz, wet Lightning impulse withstand voltage, (1,2/50, pos.) Minimum Arcing distance Minimum creepage distance Specified mechanical load (SML) Routine test load (RTL) Number of sheds Mass (approx.) Tongue in acc. to IEC 60471 (16L) Clevis in acc. to IEC 60471 (16L) SML and RTL are in acc. to IEC 61109 Material Data: Insulator End Fitting Humpback Split Pin
E-CR Glassfibre rod with HTV Silicone Rubber Housing Steel (cast) Hot Dip Galv. Acc. to EN ISO 1461 Stainless steel
10 | Page
Drawing number One minute power frequency withstand voltage, 50Hz, wet Lightning impulse withstand voltage, (1.2/50, pos.) Arcing distance Minimum creepage distance Specified mechanical load (SML) Routine test load (RTL) Number of sheds (small/large) Material fittings Mass (approx.) SML and RTL are in acc. to IEC 61109 Galvanizing (h.d.g.) acc. to EN ISO 1461
11 | Page
Drawing number One minute power frequency withstand voltage, 50Hz, wet Lightning impulse withstand voltage, 1,2/50, pos. Minimum Arcing distance Minimum creepage distance Specified mechanical load (SML) Routine test load (RTL) Number of sheds (small/large) Mass(approx.) Tongue / Clevis coupling size acc. to IEC 60471 (19L) SML and RTL are in acc. to IEC 61109 Material Data: Insulator End Fitting Clevis Pin Split Pin
E-CR Glassfibre rod with HTV Silicone Rubber Housing Drop forged steel - Hot Dip Galv. acc. to EN ISO 1461
12 | Page
(SP-AUSNET APPROVED)
Drawing number One minute power frequency withstand voltage, 50Hz, wet Dry power frequency withstand voltage (50Hz) Lightning impulse withstand voltage, (1.2/50, pos.) Minimum Arcing distance Minimum creepage distance Specified mechanical load (SML) Routine test load (RTL) Number of sheds (small/large) Mass (approx.) Ball in acc. to IEC 60120 (16) Y-Clevis in acc. to IEC 61466-1 (19) SML and RTL are in acc. to IEC 61109 Material Data: Insulator: End Fittings: Y-Clevis Pin: Humpback Split Pin:
144 021-019 230 kV 250 kV 400 kV 720 mm 2250 mm 120 kN 60 kN 15/16 3.5
E-CR Glassfibre rod with HTV Silicone Rubber Housing Drop forged steel - Hot Dip Galv. acc. to EN ISO 1461 H.T. Steel (Grade 8.8) - Hot Dip Galv. acc. to EN ISO 1461 Stainless Steel
13 | Page
Drawing number System Voltage, Um One minute power frequency withstand voltage, 50Hz, wet Lightning impulse withstand voltage, (1.2/50, pos.) Minimum Arcing distance Minimum creepage distance Specified mechanical load (SML) Routine test load (RTL) Number of sheds (small/large) Mass (approx.) Ball in acc. to IEC 60120 Socket in acc. to IEC 60120 (A) SML and RTL are in acc. to IEC 61109 Material Data: Insulator End Fittings
E-CR Glassfibre rod with HTV Silicone Rubber Housing Drop forged steel - Hot Dip Galv. acc. to EN ISO 1461 Stainless Steel
Cotter Pin
14 | Page
Drawing number One minute power frequency withstand voltage, 50Hz, wet Lightning impulse withstand voltage, (1,2/50, pos.) Minimum Arcing distance Minimum creepage distance Specified mechanical load (SML) Routine test load (RTL) Number of sheds (small/large) Mass (approx.) Ball in acc. to IEC 60120 (16) Socket in acc. to IEC 60120 (16A) SML and RTL are in acc. To IEC 61109 Material Data: Insulator End Fittings Cotter Pin
E-CR Glassfibre rod with HTV Silicone Rubber Housing Drop forged steel - Hot Dip Galv. acc. to EN ISO 1461 Stainless Steel
15 | Page
Drawing number One minute power frequency withstand voltage, 50Hz, wet Lightning impulse withstand voltage, 1,2/50, pos. Minimum Arcing distance Minimum creepage distance Specified mechanical load (SML) Routine test load (RTL) Number of sheds Mass (approx.) Eye in acc. to IEC 61466 (24) SML and RTL are in acc. to IEC 61109 Material Data: Insulator End Fittings
E-CR Glassfibre rod with HTV Silicone Rubber Housing Drop forged steel - Hot Dip Galv. acc. to EN ISO 1461
16 | Page
Drawing number One minute power frequency withstand voltage, 50Hz, wet Lightning impulse withstand voltage, 1,2/50, pos. Minimum Arcing distance Minimum creepage distance Specified mechanical load (SML) Routine test load (RTL) Number of sheds (small/large) Mass (approx.) Ball in acc. to IEC 60120 (16) Eye in acc. to IEC 61466 (24) SML and RTL are in acc. to IEC 61109 Material Data: Insulator End Fittings
E-CR Glassfibre rod with HTV Silicone Rubber Housing Drop forged steel - Hot Dip Galv. acc. to EN ISO 1461
17 | Page
Drawing number One minute power frequency withstand voltage, 50Hz, wet Lightning impulse withstand voltage, 1,2/50, pos. Minimum Arcing distance Minimum creepage distance Specified mechanical load (SML) Routine test load (RTL) Number of sheds (small/large) Mass (approx.) Eye in acc. to IEC 61466-1 (24) SML and RTL are in acc. to IEC 61109 Material Data: Insulator End Fitting
E-CR Glassfibre rod with HTV Silicone Rubber Housing Drop forged steel - Hot Dip Galv. acc. to EN ISO 1461
18 | Page
Drawing number One minute power frequency withstand voltage, 50Hz, wet Lightning impulse withstand voltage, (1.2/50, pos.) Arcing distance Minimum creepage distance Specified cantilever load (SCL) Maximum design cantilever load (MDCL) Number of small/large sheds Weight SCL and MDCL are in acc. to IEC 61952 Galvanizing (h.d.g.) acc. to EN ISO 1461
19| Page
Drawing number One minute power frequency withstand voltage, 50Hz, wet Lightning impulse withstand voltage, (1.2/50, pos.) Arcing distance Minimum creepage distance Specified cantilever load (SCL) Maximum design cantilever load (MDCL) Number of small/large sheds Weight SCL and MDCL are in acc. to IEC 61952 Galvanizing (h.d.g.) acc. to EN ISO 1461
145 241-015 140 kV 350 kV 580 mm 2250 mm 12.5 kN 5.5 kN 9/10 12.5 kg
20| Page
Drawing number One minute power frequency withstand voltage, 50Hz, wet Lightning impulse withstand voltage, (1.2/50, pos.) Minimum Arcing distance Minimum creepage distance Specified cantilever load (SCL) Maximum design cantilever load (MDCL) Specified mechanical tensile load (SML) Number of small/large sheds Mass (Approx.) SCL and MDCL are in acc. to IEC 61952 Material Data: Insulator End Fittings Bendable Base
E-cr Glassfibre rod with HTV Silicone Rubber Housing Steel - Hot Dip Galvanized, Pressed Base Plate Steel - Press Formed & Hot Dip Galvanized, acc. to EN ISO 1461
21 | Page
Drawing number One minute power frequency withstand voltage, 50Hz, wet Lightning impulse withstand voltage, (1.2/50, pos.) Minimum Arcing distance Minimum creepage distance Specified cantilever load (SCL) Maximum design cantilever load (MDCL) Number of small/large sheds Mass (Approx.) SCL and MDCL are in acc. to IEC 61952 Material Data: Insulator End Fittings Bendable Base
E-CR Glassfibre rod with HTV Silicone Rubber Housing Steel - Hot Dip Galvanized, acc. to EN ISO 1461 Plate Steel - Press Formed & Hot Dip Galvanized, acc. to EN ISO 1461
22| Page
Drawing number One minute power frequency withstand voltage, 50Hz, wet Lightning impulse withstand voltage, 1,2/50, pos.) Arcing distance Minimum creepage distance Specified cantilever load (SCL) Maximum design cantilever load (MDCL) Number of sheds (small/large) SCL and MDCL are in acc. to IEC 61952
Galvanizing (h.d.g.) acc. to EN ISO 1461 Insulator: E-cr Glassfibre rod with HTV Silicone Rubber Housing End Fitting: Steel, Hot Dip Galvanized, Pressed Base.
23 | Page
Drawing number One minute power frequency withstand voltage, 50Hz, wet Lightning impulse withstand voltage, (1.2/50, pos.) Minimum Arcing distance Minimum creepage distance Specified cantilever load (SCL) Maximum design cantilever load (MDCL) Specified mechanical tensile load (SML) Number of small/large sheds Mass (Approx.) Material Data: Insulator End Fittings
E-cr Glassfibre rod with HTV Silicone Rubber Housing Steel - Hot Dip Galvanized, acc. to EN ISO 1461
24 | Page
MV Technology Solutions
MV Technology Solutions is an Australian company that supplies a diverse range of high quality products for Power and Rail sector throughout Australia and New Zealand
OUR OFFERINGS
MV Technology Solutions only partner with leading brands to ensure your products are of high quality and meet both our local electrical requirements and withstand our vast variety of climates within Australia and New Zealand
TECHNICAL SUPPORT
MV Technology Solutions have the capabilities to assist you in correct selection of your product requirements ensuring your equipment will meet the desired application for every project on every occasion.
CUSTOMER SERVICE
Please contact our customer service office for any further information Ph: +61 (0) 2 9726 7702 Flowline Industries Pty Ltd Fax: +61 (0)2 9726 7703 Email: info@mvtechnology.com.au