Você está na página 1de 84

TRANSFORMERS

&

INDUCTORS

MYRRA
...Of course !

COMPANY PROFILE
Myrra
is a major supplier in high quality for electronics components. Myrra has established a worldwide reputation.
EUROPE 40% ASIE 18% USA 42 %

A wide range of products : We offer application specific transformers, inductors, chokes and coils,
in two technologies high frequency and 50 hz technology, enabling us to serve a number of major markets.

MAGNETICS PRODUCTS
TWO TECHNOLOGIES

50 HZ

HF

APPLICATIONS

CONVERSION

MEASURING

FILTERING

P R O D U C T

L I N E S

www.myrrel.com

Myrra reserves the right to modify the products without notice in compliance with international standards.

P R O D U C T

I N D E X

TECHNICAL INFORMATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

I ENCAPSULATED TRANSFORMERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 to 25
44000 SERIES 0.6 VA to 2.8VA / EI30-5 to EI30-18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 to 13 3.2VA to 30 VA / EI38 to EI66 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 to 19 WITH OTHER BOXES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 45000 SERIES 1 VA to 60 VA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 to 24 FLF / FLC SERIES 3.2 VA to 240 VA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

I HIGH FREQUENCY FERRITE

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 to 75

POWER FERRITE TRANSFORMERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 to 48 FLYBACK TRANSFORMERS RANGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 TRANSFORMERS / CONTROL CIRCUITS CROSS REFERENCE LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 1 W to 12 W 10 W to 30 W EE16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 to 38 EL19 EF20 EE25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 to 42

35 W to 180 W ETD29 to ETD44 ERL28 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 to 48 COMMON MODE CHOKES FOR EMI SUPPRESSION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 to 53 TOROIDAL CHOKES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 CURRENT TRANSFORMERS RANGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 to 66 PULSE TRANSFORMER RANGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 to 72 POWER LINE COMMUNICATION COUPLING TRANSFORMERS . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 to 75

I ELECTRONIC TRANSFORMERS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 to 79

I SURFACE MOUNT CHOKES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 I THROUGH HOLES CHOKES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

TECHNICAL INFORMATION
RATED PRIMARY VOLTAGE (V)
This is the supply voltage assigned to the transformer by the manufacturer.

RATED SECONDARY VOLTAGE (V)


This is the secondary output voltage assigned to the transformer when supplied with the rated primary voltage, frequency range, rated secondary current, all assigned by the manufacturer for the specified operating conditions of the transformer.

RATED POWER (VA)


The specified power levels in this catalogue are the secondary power levels, in other words, those available when the transformer is loaded. It is the product of the RMS rated secondary voltage by the RMS rated current. If the transformer has more than one output winding, the rated power denotes the maximum sum of the products of RMS rated secondary voltage by the RMS rated secondary current, respectively. This rated power is defined for rated ambient temperature conditions. example : P = 3,2 VA ta 70/B The transformer can deliver 3.2VA at maximum ambient (70C), the load consisting of a resistor load defined by R(load) = U(sec)2/P (assigned U sec & P values), heating does not exceed the relevant limit for Class B components used in this construction. NOTE : When the transformer is intended to supply DC voltage and current in conjunction with rectifiers and smoothing capacitors, the VA power required from the transformer is far higher than the U(DC) and I(DC) product. To help you to determine the true transformer power, our Technical Department is at your disposal.

AMBIENT TEMPERATURE (ta)


The maximum temperature at which the transformer may be operated continuously under nominal conditions of use. It is the air temperature measured close to the transformer after thermal stabilization when operating at rated conditions.

HEATING
The increase of the winding temperature when operating at rated conditions and maximum ambient temperature. The heating must be determined by the resistance method.

TEMPERATURE CLASS
The international classification of temperature classes is as follows : A E B F 105C 120C 130C 155C H 200 220 250 180 C 200 C 220 C 250 C

It defines the maximum temperature the transformer components must withstand in continuous operation, in compliance with the N 85 IEC publication classification. There insulating materials are therefore certificated for the thermal index corresponding to the declared class in accordance with N 216 IEC standard.

PARTICULAR POINTS OF EN 61558-2-6 STANDARD FOR SAFETY TRANSFORMERS


On-load secondary voltage tolerance. This should not differ from the rated value by more than : 10% for transformers with build-in resistance to short-circuits (a supplement of 5% is granted on the 2 nd secondary for tranformers with 2 secondaries). 5% for other transformers whatever the secondaries number. Off-load secondary voltage. The values given in this catalogue are maximum theoretical values. NOTE : For safety transformers, this should never exceed 50 V rms. In the case of a transformer with several secondaries, the sum of the secondary voltages should be less tan 50 V rms.

ADAPTED TRANSFORMERS FROM THE STANDARDS SERIES


Any transformer whose requires Power and Ambient corresponding to those of our 44000 & 45000 range, and whose secondary voltage can fit in our minimum to maximum secondary range will be covered by EN61558-2-6,EN60950, or UL506 approvals, depending on the effective choice .

SPECIAL TRANFORMERS
MYRRA can use the 44000, 45000 or 46000 standard ranges to examine any transformer for compliance with your specifications and with international standards. On request, we can add thermal protection, thermal fuse, thermal switch-CTP. In certain cases, the addition of thermal protection enables the ambient temperature to be increased, while still complying with EN 61558.

0,6 VA

EI 30-5

SERIE 44000

EN 61558-2-6

EN 60950

UL 5085

Vacuum filling Two compartments bobbins Self-extinguishing plastics UL 94 VO Degree of protection IP 00 40 grams weight Resin class B CEI 85 (20 000 h testing to CEI 126) Inherently short-circuits proof Insulation voltage 4 KV 100 % tested production Certification : CCA procedure on request
7 9

QUALITY IN SERIES
PRIMARY VOLTAGE 117 V
Protection

Reference

Secondary voltage V
6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

Secondary current mA
100 66 50 40 33 25 2 x 50 2 x 33 2 x 25 2 x 20 2 x 17 2 x 12

No-load voltage V
9,94 14,95 19,9 24,9 29,9 39,8 2 x 9,94 2 x 14,95 2 x 19,9 2 x 24,9 2 x 29,9 2 x 39,8

Ambient Temperature C
T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B

Rating VA
0,6 0,6 0,6 0,6 0,6 0,6 0,6 0,6 0,6 0,6 0,6 0,6

44025 44026 44027


6 7 5 9 10 1

44028 44029 44030 44031 44032 44033

5 6 7

1 9 10

Recommended layout for transformers with 1 secondary winding (Allows the use of a transformer with 2 secondary windings)

44034 44035 44036

PRIMARY VOLTAGE 230 V


Protection

Reference

Secondary voltage V
6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

Secondary current mA
100 66 50 40 33 25 2 x 50 2 x 33 2 x 25 2 x 20 2 x 17 2 x 12

No-load voltage V
9,94 14,95 19,9 24,9 29,9 39,8 2 x 9,94 2 x 14,95 2 x 19,9 2 x 24,9 2 x 29,9 2 x 39,8

Ambient Temperature C
T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B

Rating VA
0,6 0,6 0,6 0,6 0,6 0,6 0,6 0,6 0,6 0,6 0,6 0,6

44013 44014 44015 44016 44017 44018 44019 44020 44021 44022* 44023* 44024*

ENCAPSULATED TRANSFORMERS

*To be noted : * marked transformers are non approved. Those transformers meet all requirement of EN 61558-2-4.

44000 SERIES

1-1,8 VA

EI 30-10,5

SERIE 44000

PRIMARY VOLTAGE 117 V


Protection Reference
44061 44062 44063 44064 44065 44066 44067 44068 44069 44070 44071 44072

Secondary voltage V
6 9 12 15 18 24 2X6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

Secondary current mA
167 111 83 67 56 42 2 x 83 2 x 56 2 x 42 2 x 33 2 x 28 2 x 21

No-load voltage V
8,6 12,9 17,2 21,6 25,9 37,9 2 x 8,6 2 x 12,9 2 x 19 2 x 23,6 2 x 24,9 2 x 37,9

Ambient Temperature C
T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B

Rating VA
1 1 1 1 1 1 1 1 1 1 1 1 1 Secondary winding 7 9

EN 61558-2-6

Vacuum filling Two compartments bobbins Self-extinguishing plastics UL 94 VO Degree of protection IP 00 70 grams weight Resin class B CEI 85 (20 000 h testing to CEI 126) Inherently short-circuits proof 30 V and 36 V models are VDE EN 61558-2-6 certified (production on request)

44338 44339 44340 44341 44342 44343 44344 44345 44346 44347 44348* 44349*

6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

250 167 125 100 83 63 125 83 63 50 42 31

10,1 15,3 20,2 25,3 31,2 43,3 2 x 10,1 2 x 15,3 2 x 20,2 2 x 25,0 2 x 31 2 x 43

ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B

1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5

5 1 Primary winding 2 Secondary windings 6 7 9 10

Primary winding Recommended layout for transformers with 1 secondary winding

6 7 5

9 10 1

44840

6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15

300 200 150 120 100 75 2 x 150 2 x 100 2 x 75 2 x 60

10,1 15,2 20,3 27,3 30,4 40,6 2 x 10,1 2 x 15,2 2 x 20,3 2 x 27,3

ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B

1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 (Allows the use of a transformer with 2 secondary windings)

ENCAPSULATED TRANSFORMERS

44841 44842 44843 44844 44845 44846

44000 SERIES

44847 44848 44849

1-1,8 VA

EI 30-10,5

SERIE 44000

PRIMARY VOLTAGE 230 V


EN 60950 UL 5085

Protection

Reference
44049 44050 44051 44052 44053 44054 44055 44056 44057 44058 44059 44060*

Secondary voltage V
6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18

Secondary current mA
167 111 83 67 56 42 2 x 83 2 x 56 2 x 42 2 x 33 2 x 28 2 x 21

No-load voltage V
8,6 12,9 17,2 21,6 25,9 37,9 2 x 8,6 2 x 12,9 2 x 19 2 x 23,6 2 x 24,9 2 x 37,9

Ambient Temperature C
T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B

Rating VA
1 1 1 1 1 1 1 1 1 1 1 1

Insulation voltage 4 KV 100 % tested production Certification : CCA procedure on request *To be noted 2 x 15 V and 2 x 24 V models are non-approved. Those transformers meet all requirement of EN 61558-2-4

2 x 24 Items usually available on stock 44326 44327 44328 44329 44330 44331 44332 44333 44334 44335 44336* 44337* 6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

250 167 125 100 83 63 125 83 63 50 42 31

10,1 15,3 20,2 25,3 31,2 43,3 2 x 10,1 2 x 15,3 2 x 20,2 2 x 25,0 2 x 31 2 x 43

ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B

1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5

44830 44831 44832 44833 44834 44835 44836 44837 44838 44839*

6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15

300 200 150 120 100 75 2 x 150 2 x 100 2 x 75 2 x 60

10,1 15,2 20,3 27,3 30,4 40,6 2 x 10,1 2 x 15,2 2 x 20,3 2 x 27,3

ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B ta 70/B

1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8

ENCAPSULATED TRANSFORMERS

44000 SERIES

1,5-1,8 VA

EI 30-12,5

SERIE 44000

PRIMARY VOLTAGE 117 V


Protection Reference
44097 44098 44099 44100 44101 44102 44103 44104 44105 44106 44107 44108

Secondary voltage V
6 9 12 15 18 24 2X6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

Secondary current mA
250 167 125 100 83 63 2 x 125 2 x 83 2 x 63 2 x 50 2 x 42 2 x 31

No-load voltage V
9,7 14,5 19,3 24,2 29,8 38,6 2 x 9,7 2 x 15 2 x 19,3 2 x 24,2 2 x 29 2 x 38,6

Ambient Temperature C
T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B

Rating VA
1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1 Secondary winding 7 9 EN 61558-2-6

Vacuum filling Two compartments bobbins Self-extinguishing plastics UL 94 VO Degree of protection IP 00 80 grams weight Resin class B CEI 85 (20 000 h testing to CEI 126) Inherently short-circuits proof 30 V model is VDE EN 61558-2-6 certified (production on request)

44726 44727 44728 44729 44730 44731 44732 44733 44734 44735 44736 44737

6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

283 189 142 113 94 71 2 x 142 2 x 94 2 x 71 2 x 57 2 x 47 2 x 35

9,8 14,8 19,7 24,6 30,3 39,3 2 x 9,8 2 x 15,2 2 x 19,7 2 x 24,6 2 x 29,5 2 x 39,3

T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B

1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7 Recommended layout for transformers with 1 secondary winding 5 1 5 1 Primary winding 2 Secondary windings 6 7 9 10

Primary winding

44738

6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

300 200 150 120 100 75 2 x 150 2 x 100 2 x 75 2 x 60 2 x 50 2 x 38

9,8 14,8 19,7 24,6 30,3 39,3 2 x 9,8 2 x 15,2 2 x 19,7 2 x 24,6 2 x 29,5 2 x 39,3

T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B

1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8

ENCAPSULATED TRANSFORMERS

6 7 5

9 10 1

44739 44740 44741 44742 44743 44744

(Allows the use of a transformer with 2 secondary windings)

44000 SERIES

44745 44746 44747 44748 44749

QUALITY IN SERIES

1,5-1,8 VA

EI 30-12,5

SERIE 44000

PRIMARY VOLTAGE 230 V


Protection
EN 60950 UL 5085

Reference
44085 44086 44087 44088 44089

Secondary voltage V
6 9 12 15 18 24 2X6 2x9 2 x 12 2 x 15 2 x 18

Secondary current mA
250 167 125 100 83 63 2 x 125 2 x 83 2 x 63 2 x 50 2 x 42 2 x 31

No-load voltage V
9,7 14,5 19,3 24,2 29,8 38,6 2 x 9,7 2 x 15 2 x 19,3 2 x 24,2 2 x 29 2 x 38,6

Ambient Temperature C
T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B

Rating VA
1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5

Insulation voltage 4 KV 100 % tested production Certification : CCA procedure on request

*To be noted : 2 x 18 V and 2 x 24 V models are nonapproved. Those transformers meet all requirement of EN 61558-2-4

44090 44091 44092 44093 44094 44095* 44096*

2 x 24 Items usually available on stock 44647 44648 44649 44650 44651 44652 44653 44654 44655 44656 44483* 44484* 6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

283 189 142 113 94 71 2 x 142 2 x 94 2 x 71 2 x 57 2 x 47 2 x 35

9,8 14,8 19,7 24,6 30,3 39,3 2 x 9,8 2 x 15,2 2 x 19,7 2 x 24,6 2 x 29,5 2 x 39,3

T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B

1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7

44657 44658 44659 44660 44661 44662 44663 44664 44665 44666 44485* 44486*

6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

300 200 150 120 100 75 2 x 150 2 x 100 2 x 75 2 x 60 2 x 50 2 x 38

9,8 14,8 19,7 24,6 30,3 39,3 2 x 9,8 2 x 15,2 2 x 19,7 2 x 24,6 2 x 29,5 2 x 39,3

T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B

1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8

ENCAPSULATED TRANSFORMERS

44000 SERIES

2-2,4 VA

EI 30-15,5

SERIE 44000

PRIMARY VOLTAGE 117 V


Protection Reference
44133 44134 44135 44136 44137 44138 44139 44140 44141 44142 44143 44144

Secondary voltage V
6 9 12 15 18 24 2X6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

Secondary current mA
333 222 167 133 111 83 2 x 167 2 x 111 2 x 83 2 x 67 2 x 56 2 x 42

No-load voltage V
10,4 15,5 20,7 25,8 30,8 41,4 2 x 10,4 2 x 15,4 2 x 20,7 2 x 25,8 2 x 30,8 2 x 41,4

Ambient Temperature C
T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B

Rating VA
2 2 2 2 2 2 2 2 2 2 2 2 1 Secondary winding 7 9 EN 61558-2-6

Vacuum filling Two compartments bobbins Self-extinguishing plastics UL 94 VO Degree of protection IP 00 100 grams weight Resin class B CEI 85 (20 000 h testing to CEI 126) Inherently short-circuits proof 30 V model is VDE EN 61558-2-6 certified (production on request) Insulation voltage 4 KV

44750 44751 44752 44753 44754 44755 44756 44757 44758 44759 44760 44761

6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

383 256 192 153 128 96 2 x 192 2 x 128 2 x 96 2 x 77 2 x 64 2 x 48

10,5 15,5 21 25,3 31 42 2 x 10,5 2 x 15,5 2 x 21 2 x 24,5 2 x 31 2 x 42

T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B

2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 5 1 Primary winding Recommended layout for transformers with 1 secondary winding 2 Secondary windings 6 7 9 10 5 1 Primary winding

44762

6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

400 267 200 160 133 100 2 x 200 2 x 133 2 x 100 2 x 80 2 x 67 2 x 50

10,5 15,5 21 25,3 31 42 2 x 10,5 2 x 15,5 2 x 21 2 x 24,5 2 x 31 2 x 42

T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B

2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4

ENCAPSULATED TRANSFORMERS

44763 44764 44765 44766 44767 44768

6 7 5

9 10 1

44000 SERIES

44769 44770 44771 44772 44773

(Allows the use of a transformer with 2 secondary windings)

10

2-2,4 VA

EI 30-15,5

SERIE 44000

PRIMARY VOLTAGE 230 V


Protection
EN 60950 UL 5085

Reference
44121 44122 44123 44124

Secondary voltage V
6 9 12 15 18 24 2X6 2x9 2 x 12 2 x 15 2 x 18

Secondary current mA
333 222 167 133 111 83 2 x 167 2 x 111 2 x 83 2 x 67 2 x 56 2 x 42

No-load voltage V
10,4 15,5 20,7 25,8 30,8 41,4 2 x 10,4 2 x 15,4 2 x 20,7 2 x 25,8 2 x 30,8 2 x 41,4

Ambient Temperature C
T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B

Rating VA
2 2 2 2 2 2 2 2 2 2 2 2

100 % tested production Certification : CCA procedure on request

*To be noted : 2 x 18 V and 2 x 24 V models are nonapproved. Those transformers meet all requirement of EN 61558-2-4

44125 44126 44127 44128 44129 44130 44131* 44132*

2 x 24 Items usually available on stock 44667 44668 44669 44670 44671 44672 44673 44674 44675 44676 44487* 44488* 6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

383 256 192 153 128 96 2 x 192 2 x 128 2 x 96 2 x 77 2 x 64 2 x 48

10,5 15,5 21 25,3 31 42 2 x 10,5 2 x 15,5 2 x 21 2 x 24,5 2 x 31 2 x 42

T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B

2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3

44677 44678 44679 44680 44681 44682 44683 44684 44685 44686 44489* 44490*

6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

400 267 200 160 133 100 2 x 200 2 x 133 2 x 100 2 x 80 2 x 67 2 x 50

10,5 15,5 21 25,3 31 42 2 x 10,5 2 x 15,5 2 x 21 2 x 24,5 2 x 31 2 x 42

T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B

2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4

ENCAPSULATED TRANSFORMERS

11

44000 SERIES

2,3-2,8 VA

EI 30-18

SERIE 44000

PRIMARY VOLTAGE 117 V


Protection Reference
44169 44170 44171 44172 44173 44174 44175 44176 44177 44178 44179 44180

EN 61558-2-6

Secondary voltage V
6 9 12 15 18 24 2X6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

Secondary current mA
383 256 192 153 128 96 2 x 192 2 x 128 2 x 96 2 x 77 2 x 64 2 x 48

No-load voltage V
10,5 15,7 21 25,9 31,4 41,9 2 x 10,5 2 x 15,7 2 x 21 2 x 25,9 2 x 31,4 2 x 41,9

Ambient Temperature C
T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B

Rating VA
2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3

Vacuum filling Two compartments bobbins Self-extinguishing plastics UL 94 VO Degree of protection IP 00 70 grams weight Resin class B CEI 85 (20 000 h testing to CEI 126) Inherently short-circuits proof 30 V model is VDE EN 61558-2-6 certified (production on request)

1 Secondary winding 7 9

44774 44775 44776 44777 44778 44779 44780 44781 44782 44783 44784 44785

6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

450 300 225 180 150 113 2 x 225 2 x 150 2 x 113 2 x 90 2 x 75 2 x 56

10,5 15,4 21,1 26,3 30,9 42 2 x 10,5 2 x 15,4 2 x 21,1 2 x 26,3 2 x 31,5 2 x 42,1

T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B

2,7 2,7 2,7 2,7 2,7 2,7 2,7 2,7 2,7 2,7 2,7 2,7 Recommended layout for transformers with 1 secondary winding 5 1 5 1 Primary winding 2 Secondary windings 6 7 9 10

Primary winding

44786

6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

467 311 233 187 156 117 2 x 233 2 x 156 2 x 117 2 x 93 2 x 77 2 x 58

10,5 15,4 21,1 26,3 30,9 42,1 2 x 10,5 2 x 15,4 2 x 21,1 2 x 26,3 2 x 31,5 2 x 42,1

T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B

2,8 2,8 2,8 2,8 2,8 2,8 2,8 2,8 2,8 2,8 2,8 2,8

ENCAPSULATED TRANSFORMERS

6 7 5

9 10 1

44787 44788 44789 44790 44791 44792

(Allows the use of a transformer with 2 secondary windings)

44000 SERIES

44793 44794 44795 44796 44797

12

2,3-2,8 VA

EI 30-18

SERIE 44000

EN 60950

UL 5085

PRIMARY VOLTAGE 230 V


Protection Reference
44157 44158

Insulation voltage 4 KV 100 % tested production Certification : CCA procedure on request

Secondary voltage V
6 9 12 15 18 24 2X6 2x9 2 x 12 2 x 15 2 x 18

Secondary current mA
383 256 192 153 128 96 2 x 192 2 x 128 2 x 96 2 x 77 2 x 64 2 x 48

No-load voltage V
10,5 15,7 21 25,9 31,4 41,9 2 x 10,5 2 x 15,7 2 x 21 2 x 25,9 2 x 31,4 2 x 41,9

Ambient Temperature C
T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B

Rating VA
2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3

*To be noted : 2 x 18 V and 2 x 24 V models are nonapproved. Those transformers meet all requirement of EN 61558-2-4

44159 44160 44161 44162 44163 44164 44165 44166 44167* 44168*

2 x 24 Items usually available on stock 44687 44688 44689 44690 44691 44692 44693 44694 44695 44696 44491* 44492* 6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

450 300 225 180 150 113 2 x 225 2 x 150 2 x 113 2 x 90 2 x 75 2 x 56

10,5 15,4 21,1 26,3 30,9 42 2 x 10,5 2 x 15,4 2 x 21,1 2 x 26,3 2 x 31,5 2 x 42,1

T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B

2,7 2,7 2,7 2,7 2,7 2,7 2,7 2,7 2,7 2,7 2,7 2,7

44697 44698 44699 44700 44701 44702 44703 44704 44705 44706 44493* 44494*

6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

467 311 233 187 156 117 2 x 233 2 x 156 2 x 117 2 x 93 2 x 70 2 x 58

10,5 15,4 21,1 26,3 30,9 42,1 2 x 10,5 2 x 15,4 2 x 21,1 2 x 26,3 2 x 31,5 2 x 42,1

T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B T 40 B

2,8 2,8 2,8 2,8 2,8 2,8 2,8 2,8 2,8 2,8 2,8 2,8

ENCAPSULATED TRANSFORMERS

13

44000 SERIES

3,2 VA

EI 38-13,6

SERIE 44000

PRIMARY VOLTAGE 117 V


Secondary protection mA
630 400 315 250 200 160 315 200 160 125 100 80

EN 61558-2-6 Vacuum filling Two compartments bobbins Self-extinguishing plastics UL 94 VO Degree of protection IP 00 150 grams weight Resin class B CEI 85 (20 000 h testing to CEI 126) Fuse protection on secondary side (see diagram) to be assumed by customer

Reference

Secondary voltage V
6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

Secondary current mA
533 356 267 213 178 133 2 x 267 2 x 178 2 x 133 2 x 107 2 x 89 2 x 67

No-load voltage V
8 12 16 20 24,1 32,1 2x8 2 x 12 2 x 16 2 x 20 2 x 24 2 x 32,1

Ambient Temperature C
T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B

Rating VA
3,2 3,2 3,2 3,2 3,2 3,2 3,2 3,2 3,2 3,2 3,2 3,2

44205 44206 44207 44208 44209 44210 44211 44212 44213 44214 44215 44216

2 Secondary windings 1 Secondary winding 6 7 6 7 9 10 9 10

6 7 5

9 10 1

Primary winding

Primary winding

Recommended layout for transformers with 1 secondary winding (Allows the use of a transformer with 2 secondary windings)

5 VA

EI 42-14,8

SERIE 44000

PRIMARY VOLTAGE 117 V


Secondary protection mA

EN 61558-2-6 Vacuum filling Two compartments bobbins Self-extinguishing plastics UL 94 VO Degree of protection IP 00 200 grams weight Resin class B CEI 85 (20 000 h testing to CEI 126) Fuse protection on secondary side (see diagram) to be assumed by customer

Reference

Secondary voltage V
6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

Secondary current mA
833 556 417 333 278 208 2 x 417 2 x 278 2 x 208 2 x 167 2 x 139 2 x 104

No-load voltage V
8,4 12,6 16,9 21 25,3 33,7 2 x 8,4 2 x 12,6 2 x 16,9 2 x 21 2 x 25,3 2 x 33,7

Ambient Temperature C
T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B

Rating VA
5 5 5 5 5 5 5 5 5 5 5 5

ENCAPSULATED TRANSFORMERS

800 630 400 315 315 200 400

44241 44242 44243 44244 44245 44246 44247 44248 44249 44250 44251 44252

2 Secondary windings 1 Secondary winding 6 7 6 7 9 10 9 10

6 7 5

9 10 1

44000 SERIES

315 200 160 160 100

Primary winding

Primary winding

Recommended layout for transformers with 1 secondary winding (Allows the use of a transformer with 2 secondary windings)

14

3,2 VA

EI 38-13,6

SERIE 44000

EN 60950

UL 5085

30 V and 36 V models are VDE EN 61558-2-6 certified (production on request) Insulation voltage 4 KV 100 % tested production Certification : CCA procedure on request *To be noted : 2 x 24 V model is non-approved. Those transformers meet all requirement of EN 61558-2-4

PRIMARY VOLTAGE 230 V


Secondary protection mA
630 400 315 250 200 160 315 200 160

Reference

Secondary voltage V
6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

Secondary current mA
533 356 267 213 178 133 2 x 267 2 x 178 2 x 133 2 x 107 2 x 89 2 x 67

No-load voltage V
8 12 16 20 24,1 32,1 2x8 2 x 12 2 x 16 2 x 20 2 x 24 2 x 32,1

Ambient Temperature C
T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B

Rating VA
3,2 3,2 3,2 3,2 3,2 3,2 3,2 3,2 3,2 3,2 3,2 3,2

44193 44194 44195 44196 44197 44198 44199 44200 44201 44202 44203 44204*

4.5+0.5

125 100 80

5 VA

EI 42-14,8

SERIE 44000

EN 60950

UL 5085

30 V and 36 V models are VDE EN 61558-2-6 certified (production on request) Insulation voltage 4 KV 100 % tested production Certification : CCA procedure on request *To be noted : 2 x 24 V model is non-approved. Those transformers meet all requirement of EN 61558-2-4

PRIMARY VOLTAGE 230 V


Secondary protection mA
800 630 400 315 315 200 400 315 200

Reference

Secondary voltage V
6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

Secondary current mA
833 556 417 333 278 208 2 x 417 2 x 278 2 x 208 2 x 167 2 x 139 2 x 104

No-load voltage V
8,4 12,6 16,9 21 25,3 33,7 2 x 8,4 2 x 12,6 2 x 16,9 2 x 21 2 x 25,3 2 x 33,7

Ambient Temperature C
T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B

Rating VA

44230 44231 44232 44233 44234 44235 44236 44237 44238 44239 44240*

5 5 5 5 5 5 5 5 5 5 5

ENCAPSULATED TRANSFORMERS

44229

160 160 100

15

44000 SERIES

5+0.5

10 VA

EI 48-16,8

SERIE 44000

PRIMARY VOLTAGE 117 V


Primary protection mA
125 125 125 125 125 125 125 125 125 125 125 125

EN 61558-2-6 Vacuum filling Two compartments bobbins Self-extinguishing plastics UL 94 VO Degree of protection IP 00 300 grams weight Resin class B CEI 85 (20 000 h testing to CEI 126) Fuse protection on primary side (see diagram) to be assumed by customer

Reference

Secondary voltage V
6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

Secondary current mA
1667 1111 833 667 556 417 2 x 833 2 x 556 2 x 417 2 x 333 2 x 278 2 x 208

No-load voltage V
7,2 10,8 14,4 18,1 21,6 28,9 2 x 7,2 2 x 10,8 2 x 14,4 2 x 18,1 2 x 21,6 2 x 28,9

Ambient Temperature C
T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B

Rating VA
10 10 10 10 10 10 10 10 10 10 10 10

44277 44278 44279 44280 44281 44282 44283 44284 44285 44286 44287 44288

2 Secondary windings 7 8 11 12

1 Secondary winding 7 8 11 12

78

11 12

6
6 Primary winding 1 6 Primary winding 1

Recommended layout for transformers with 1 secondary winding (Allows the use of a transformer with 2 secondary windings)

16 VA

EI 54-18,8

SERIE 44000

PRIMARY VOLTAGE 117 V


Secondary protection mA

EN 61558-2-6 Vacuum filling Two compartments bobbins Self-extinguishing plastics UL 94 VO Degree of protection IP 00 400 grams weight Resin class B CEI 85 (20 000 h testing to CEI 126) Fuse protection on secondary side (see diagram) to be assumed by customer

Reference

Secondary voltage V
6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

Secondary current mA
2667 1778 1333 1067 889 667 2 x 1333 2 x 889 2 x 667 2 x 533 2 x 444 2 x 333

No-load voltage V
7,4 11,1 14,7 18,4 22,1 29,3 2 x 7,4 2 x 11,1 2 x 14,7 2 x 18,4 2 x 22 2 x 29,3

Ambient Temperature C
T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B

Rating VA
16 16 16 16 16 16 16 16 16 16 16 16

ENCAPSULATED TRANSFORMERS

2,5 2,0 1,25 1 1 0,63 1,25

44313 44314 44315 44316 44317 44318 44319 44320 44321 44322 44323 44324

2 Secondary windings 8 9 13 14

1 Secondary winding 8 9 13 14

89

13 14

44000 SERIES

1 0,63 0,5 0,5 0,315

7
7 Primary winding 1 7 Primary winding 1

Recommended layout for transformers with 1 secondary winding (Allows the use of a transformer with 2 secondary windings)

16

10 VA

EI 48-16,8

SERIE 44000

EN 60950

UL 5085

30 V and 36 V models are VDE EN 61558-2-6 certified (production on request) Insulation voltage 4 KV 100 % tested production Certification : CCA procedure on request *To be noted : 2 x 24 V model is non-approved. Those transformers meet all requirement of EN 61558-2-4

PRIMARY VOLTAGE 230 V


Primary protection mA
63 63 63 63 63 63 63 63 63 63 63 63

Reference

Secondary voltage V
6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

Secondary current mA
1667 1111 833 667 556 417 2 x 833 2 x 556 2 x 417 2 x 333 2 x 278 2 x 208

No-load voltage V
7,2 10,8 14,4 18,1 21,6 28,9 2 x 7,2 2 x 10,8 2 x 14,4 2 x 18,1 2 x 21,6 2 x 28,9

Ambient Temperature C
T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B

Rating VA
10 10 10 10 10 10 10 10 10 10 10 10

44265 44266 44267 44268 44269 44270 44271 44272 44273 44274 44275 44276*

16 VA

EI 54-18,8

SERIE 44000

EN 60950

UL 5085

30 V and 36 V models are VDE EN 61558-2-6 certified (production on request) Insulation voltage 4 KV 100 % tested production Certification : CCA procedure on request *To be noted : 2 x 24 V model is non-approved. Those transformers meet all requirement of EN 61558-2-4

PRIMARY VOLTAGE 230 V


Secondary protection mA
2,500 2,000 1,25 1 1 0,63 1,25 1 0,63

Reference

Secondary voltage V
6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

Secondary current mA
2667 1778 1333 1067 889 667 2 x 1333 2 x 889 2 x 667 2 x 533 2 x 444 2 x 333

No-load voltage V
7,4 11,1 14,7 18,4 22,1 29,3 2 x 7,4 2 x 11,1 2 x 14,7 2 x 18,4 2 x 22 2 x 29,3

Ambient Temperature C
T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B

Rating VA

44302 44303 44304 44305 44306 44307 44308 44309 44310 44311 44312*

16 16 16 16 16 16 16 16 16 16 16

ENCAPSULATED TRANSFORMERS

44301

16

0,5 0,5 0,315

17

44000 SERIES

3.5+0.5

22 VA

EI 60-21

SERIE 44000

PRIMARY VOLTAGE 117 V


Primary protection mA
250 250 250 250 250 250 250 250 250 250 250 250

EN 61558-2-6 Vacuum filling Two compartments bobbins Self-extinguishing plastics UL 94 VO Degree of protection IP 00 550 grams weight Resin class B CEI 85 (20 000 h testing to CEI 126) Fuse protection on primary side (see diagram) to be assumed by customer

Reference

Secondary voltage V
6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

Secondary current mA
3667 2444 1833 1467 1222 917 2 x 1833 2 x 1222 2 x 917 2 x 733 2 x 611 2 x 458

No-load voltage V
6,8 10,3 13,7 17,1 20,5 27,3 2 x 6,8 2 x 10,3 2 x 13,7 2 x 17,1 2 x 20,5 2 x 27,3

Ambient Temperature C
T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B

Rating VA
22 22 22 22 22 22 22 22 22 22 22 22

44444 44445 44446 44447 44448 44449 44450 44451 44452 44453 44454 44455

2 Secondary windings 8 9 13 14

1 Secondary winding 8 9 13 14

8 9 7

13 14 1

Primary winding

Primary winding

Recommended layout for transformers with 1 secondary winding (Allows the use of a transformer with 2 secondary windings)

30 VA

EI 66-23

SERIE 44000

PRIMARY VOLTAGE 117 V


Primary protection mA

EN 61558-2-6 Vacuum filling Two compartments bobbins Self-extinguishing plastics UL 94 VO Degree of protection IP 00 700 grams weight Resin class B CEI 85 (20 000 h testing to CEI 126) Fuse protection on primary side (see diagram) to be assumed by customer

Reference

Secondary voltage V
6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

Secondary current mA
5000 3333 2500 2000 1667 1250 2 x 2500 2 x 1667 2 x 1250 2 x 1000 2 x 833 2 x 625

No-load voltage V
6,9 10,3 13,8 17,2 20,8 27,7 2 x 6,9 2 x 10,3 2 x 13,8 2 x 17,2 2 x 20,8 2 x 27,7

Ambient Temperature C
T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B

Rating VA
30 30 30 30 30 30 30 30 30 30 30 30

ENCAPSULATED TRANSFORMERS

315 315 315 315 315 315 315

44385 44386 44387 44388 44389 44390 44391 44392 44393 44394 44395 44396

2 Secondary windings 9 10 15 16

1 Secondary winding 9 10 15 16

9 10

15 16

44000 SERIES

8
8 Primary winding 1 8 Primary winding 1

315 315 315 315 315

Recommended layout for transformers with 1 secondary winding (Allows the use of a transformer with 2 secondary windings)

18

22 VA

EI 60-21

SERIE 44000

EN 60950

UL 5085

30 V and 36 V models are VDE EN 61558-2-6 certified (production on request) Insulation voltage 4 KV 100 % tested production Certification : CCA procedure on request *To be noted : 2 x 24 V model is non-approved. Those transformers meet all requirement of EN 61558-2-4

PRIMARY VOLTAGE 230 V


Primary protection mA
125 125 125 125 125 125 125 125 125 125 125 125

Reference

Secondary voltage V
6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

Secondary current mA
3667 2444 1833 1467 1222 917 2 x 1833 2 x 1222 2 x 917 2 x 733 2 x 611 2 x 458

No-load voltage V
6,8 10,3 13,7 17,1 20,5 27,3 2 x 6,8 2 x 10,3 2 x 13,7 2 x 17,1 2 x 20,5 2 x 27,3

Ambient Temperature C
T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B

Rating VA
22 22 22 22 22 22 22 22 22 22 22 22

44432 44433 44434 44435 44436 44437 44438 44439 44440 44441 44442 44443*

30 VA

EI 66-23

SERIE 44000

EN 60950

UL 5085

30 V and 36 V models are VDE EN 61558-2-6 certified (production on request) Insulation voltage 4 KV 100 % tested production Certification : CCA procedure on request *To be noted : 2 x 24 V model is non-approved. Those transformers meet all requirement of EN 61558-2-4

PRIMARY VOLTAGE 230 V


Primary protection mA
160 160 160 160 160 160 160 160 160 160 160 160

Reference

Secondary voltage V
6 9 12 15 18 24 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24

Secondary current mA
5000 3333 2500 2000 1667 1250 2 x 2500 2 x 1667 2 x 1250 2 x 1000 2 x 833 2 x 625

No-load voltage V
6,9 10,3 13,8 17,2 20,8 27,7 2 x 6,9 2 x 10,3 2 x 13,8 2 x 17,2 2 x 20,8 2 x 27,7

Ambient Temperature C
T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B

Rating VA

44374 44375 44376 44377 44378 44379 44380 44381 44382 44383 44384*

30 30 30 30 30 30 30 30 30 30 30

ENCAPSULATED TRANSFORMERS

44373

30

19

44000 SERIES

BOXES WITH FIXING SUPPORT

SERIE 44000

P O

4X5.0

10

6X5.0

13X2.5

14

14

16

CIRCUIT

L 0,50
55,6 64 69 74 81,5 87,2

P 0,40
34,9 37 42,3 47,3 53,3 58,6

H 0,40
28,1 32,3 34,6 38,8 44,7 48,5

X 0,50
47,5 55,0 60 65 72,5 77,5

Y 0,50

0,3
3,2 4,2 4,2 4,2

ENCAPSULATED TRANSFORMERS

EI 38 X 13,6 EI 42 X 14,8 EI 48 X 16,8 EI 54 X 18,8 EI 60 X 21 EI 66 X 23

43,5 47,5

4,2 4,2

Series 44000 transformers can be equiped with boxes with lugs and also 2,8 faston terminal tags while still conforming to the specifications in the standard references.

44000 SERIES

For boxes with 2 lugs and pin type output, add suffix 1 to the reference of the standard transformer (example : 44198-1) For boxes with 2 lugs and 2,8 faston output, add suffix 2 to the reference of the standard transformer (example : 44199-2) For boxes with 4 lugs and pin type output, add suffix 3 to the reference of the standard transformer (example : 44200-3) For boxes with 4 lugs and 2,8 faston output, add suffix 4 to the reference of the standard transformer (example : 44201-4) These models are not available on stock.

20

7X5.0

EI 54

5.0

10

6X5.0

EI 60

5.0

12

7
EI 66 7X5.0

6X5.0

11X2.5 8

5X5.0

5X5.0

EI 38

7.5

EI 42

7.5

EI 48

5X5.0

1 VA

UI 21

SERIE 45000

EN 61558-2-6

EN 60950

UL 5085

230 V supply voltage by series/parallel connection Vacuum filling One compartiment housing 1 VA Two compartments bobbins 0,8 VA Degree of protection IP 00 50 grams weight 1 VA

Resin UL 94 VO Design protection against short-circuits Insulation voltage 4 KV 100 % tested production

Conform to EN 61558 - UL 5085

PRIMARY VOLTAGE 230 V


Protection

Reference

Secondary voltage V

Secondary current mA

No-load voltage V

Ambient Temperature C

UI 21
45001 45002 6 9 12 15 18 24

230 V
167 111 83 67 56 42 17

1 VA
11,4 T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B

Type 1 VA

45003 45004 45005

22,8 28,5 34,2 45,6

Primary windings
12 7

Secondary windings

45006

QUALITY IN SERIES

ENCAPSULATED TRANSFORMERS

21

45000 SERIES

3-10 VA

UI 30

SERIE 45000

PRIMARY VOLTAGE 115 V - 230 V


Protection Reference Secondary voltage V Secondary current mA No-load voltage V Ambient Temperature C

EN 61558-2-6

UI 30 x 5,5
45292 45293 45294 45295 45296 45297 2x6 2x9 2 x12 2 x15 2 x18 2 x24 2 x 167 2 x 111 2 x 83 2 x 67 2 x 56 2 x 42

2 VA
2 x 10,2 2 x 15,9 2 x 20,4 2 x 25,5 2 x 30,6 2 x 40,8 T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B

115 V- 230 V supply voltage by series/parallel connection Vacuum filling Two compartments bobbins Degree of protection IP 00 Resin class UL 94 VO

UI 30 x 5,5
250 160 125 100 80 63 45013 45014 45015 45016 45017 45018

Secondary protection mA 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24 2 x 250 2 x 167 2 x 125 2 x 100 2 x 83 2 x 63 2 x 9,8

3 VA
T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B

2 x 14,7 2 x 19,6 2 x 24,5 2 x 29,5 2 x 39,3

UI 30 x 7,5
315 250 160 125 125 80 45019 45020 45021 45022 45023 45024

Secondary protection mA 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24 2 x 333 2 x 222 2 x 167 2 x 133 2 x 111 2 x 83 2 x 9,4

4 VA
T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B

CIRCUIT
UI 30 x 5,5 UI 30 x 7,5

RATING
2 VA/3 VA 4 VA 6 VA 10 VA

DIMENSION A
A = 17 mm A = 19 mm A = 22 mm A = 28 mm

WEIGHT
125 g 150 g 185 g 260 g

2 x 14,0 2 x 18,6 2 x 23,3 2 x 28,0 2 x 37,4

UI 30 x 10,5 UI 30 x 16,5

UI 30 x 10,5
500 315 45025 45026 45027 45028 45029 45030

Secondary protection mA 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24 2 x 500 2 x 333 2 x 250 2 x 200 2 x 167 2 x 125 2 x 8,1

6 VA
T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B
16 14 12 10 16 14 12 10

2 x 12,1 2 x 16,2 2 x 20,2 2 x 24,3 2 x 32,3

ENCAPSULATED TRANSFORMERS

250 200 160 125

230 V
3 5 7

Possible primary connections

115 V
3 5 7 1 3 5 7 1 3 5 7

Possible secondary connections

UI 30 x 16,5
125/63 125/63 45031 45032 45033 45034 45035 45036

Primary protection mA 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24 2 x 833 2 x 556 2 x 417 2 x 333 2 x 278 2 x 208 2 x 7,9

10 VA
T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B

2 x 11,9 2 x 15,9 2 x 19,8 2 x 23,7 2 x 31,7

45000 SERIES

125/63 125/63 125/63 125/63

Secondary voltage doubled

16 14 12 10

16 14 12 10

Double the secondary current

QUALITY IN SERIES

22

10-30 VA

UI 39

SERIE 45000

EN 60950

UL 5085

Fuse protection in secondary winding (see diagram) Insulation voltage 4 KV 100 % tested production Conform to EN 61558 Approval under process UL 5085 approved

PRIMARY VOLTAGE 115 V - 230 V


Primary protection
115 V/230 V mA

Reference

Secondary voltage V

Secondary current mA

No-load voltage V

Ambient Temperature C

UI 39 x 8
125/63 125/63 125/63 125/63 125/63 125/63 45037 45038 45039 45040 45041 45042 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24 2 x 833 2 x 555 2 x 416 2 x 333 2 x 277 2 x 208

10 VA
2 x 8,2 2 x 12,3 2 x 16,4 2 x 20,5 2 x 24,6 2 x 32,8 T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B

UI 39 x 10,2
160/80 160/80 160/80 160/80 160/80 160/80 45043 45044 45045 45046 45047 45048 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24 2 x 1167 2 x 778 2 x 583 2 x 467 2 x 389 2 x 292

14 VA
2 x 7,5 2 x 10,9 2 x 15,0 2 x 18,7 2 x 22,4 2 x 30,2 T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B

UI 39 x 13,5
CIRCUIT
UI 39 x 8 UI 39 x 10,2 UI 39 x 13,5 UI 39 x 17 UI 39 x 21

18 VA
2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24 2 x 1500 2 x 1000 2 x 750 2 x 600 2 x 500 2 x 375 2 x 7,4 2 x 11,0 2 x 14,7 2 x 18,3 2 x 22,0 2 x 29,4 T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B

RATING
10 VA 14 VA 18 VA 24 VA 30 VA

DIMENSION A
A = 22 mm A = 24 mm A = 27 mm A = 31 mm A = 35 mm

WEIGHT
285 g 335 g 405 g 480 g 550 g

200/100 200/100 200/100 200/100 200/100 200/100

45049 45050 45051 45052 45053 45054

UI 39 x 17

24 VA
2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24 2 x 2000 2 x 1333 2 x 1000 2 x 800 2 x 667 2 x 500 2 x 7,1 2 x 10,6 2 x 14,1 2 x 17,6 2 x 21,2 2 x 28,3 T 50 B T 50 B

250/125 250/125 250/125

45058 45059 45060

T 50 B T 50 B T 50 B

19 17

315/160 315/160 315/160 315/160

45063 45064 45065 45066

2 x 12 2 x 15 2 x 18 2 x 24

2 x 1250 2 x 1000 2 x 833 2 x 625

2 x 13,5 2 x 16,8 2 x 20,2 2 x 27,0

T 50 B T 50 B T 50 B T 50 B

23

45000 SERIES


sec 1

14 12

19 17

sec 2


sec 1

14 12

19 17

sec 2

Secondary voltage doubled

14 12

19 17

Double the secondary current

14 12

UI 39 x 21
315/160 315/160 45061 45062 2x6 2x9 2 x 2500 2 x 1667

30 VA
2 x 6,7 2 x 10,15 T 50 B T 50 B

ENCAPSULATED TRANSFORMERS

230 V

Possible primary connections

115V

Possible secondary connections

250/125 250/125 250/125

45055 45056 45057

T 50 B

40-60 VA

UI 48

SERIE 45000

EN 61558-2-6

EN 60950

UL 5085

115 V- 230 V supply voltage by series/parallel connection Vacuum filling Two compartments bobbins Degree of protection IP 00 Resin class UL 94 VO

Fuse protection in secondary winding (see diagram) Insulation voltage 4 KV 100 % tested production Conform to EN 61558 Approval under process UL 5085 approved

PRIMARY VOLTAGE 115 V - 230 V


Primary protection 115/230 V mA

Reference

Secondary voltage V

Secondary current mA

No-load voltage V

Ambient Temperature C

U I 48 x 17
400/200 400/200 400/200 400/200 400/200 400/200 45067 45068 45069 45070 45071 45072 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24 2 x 3333 2 x 2222 2 x 1667 2 x 1333 2 x 1111 2 x 833

40 VA
2 x 6,7 2 x 10,0 2 x 13,4 2 x 16,7 2 x 20,1 2 x 26,8 T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B

U I 48 x 26
630/315 630/315 630/315 630/315 630/315 630/315 45073 45074 45075 45076 45077 45078 2x6 2x9 2 x 12 2 x 15 2 x 18 2 x 24 2 x 5000 2 x 3333 2 x 2500 2 x 2000 2 x 1667 2 x 1250

60 VA
2 x 6,6 2 x 9,9 2 x 13,1 2 x 16,4 2 x 19,7 2 x 26,3 T 50 B T 50 B T 50 B T 50 B T 50 B T 50 B Possible primary connections

CIRCUIT
UI 48 x 17 UI 48 x 26

RATING
40 VA 60 VA

WEIGHT
760 g 1060 g

38,5 13,5 83 48,5 14,5 86

ENCAPSULATED TRANSFORMERS

230 V

12

115 V

12

Possible secondary connections

12

12

23

20

17

14

23

20

17

14

45000 SERIES

Secondary voltage doubled

23

20

17

14

Double the secondary current

23

20

17


14

QUALITY IN SERIES

24

3,2-240 VA

FLF / FLC SERIES

SIDE-MOUNTING TRANSFORMERS
FLF / FLC SERIES Primary voltage : 230 V 50/60 Hz Secondary voltage : 12 V ou 24 V Maximum ambient temperature : + 40 C Insulation class : B Insulation voltage : 4 kV Standards applicable : VDE 0570 - EN 61558 UL 5085 Degree of protection IP 00 Prepared for protection class II Options : 00 Standard 01 Addition of a thermal fuse (non-resettable) 02 Addition of a resettable thermal protection system On request : all primary and secondary voltages up to 500 V (consult us for details)

FLF SERIES : connection by UL-approved flexible cables (600 V/105C) AWG 18 up to 6 A standard length : AWG 16 up to 10 A 250 mm AWG 14 up to 20 A

FLC SERIES : connection by faston connectors Rating primary secondary 3,2 VA-5 VA 2,8 x 0,8 4,8 x 0,8 10 VA-22 VA 4,8 x 0,8 4,8 x 0,8 30 VA-240 VA 6,3 x 0,8 6,3 x 0,8

FLF SERIES

FLC SERIES

Primary winding

A D

Secondary winding

Secondary winding B F A D

C B E

Primary winding

Rating in VA
3,2 5 10 16 22 30 45 63 100 160* 160 185 240

References FLF 12 V
30081 30082 30083 30084 30085 30086 30087 30088 30089 30090 30091 30092 30093

FLC 24 V
30094 30095 30096 30097 30098 30099 30100 30101 30102 30103 30104 30105 30106

12 V
30107 30108 30109 30110 30111 30112 30113 30114 30115 30116 30117 30118 30119

24 V
30120 30121 30122 30123 30124 30125 30126 30127 30128 30129 30130 30131 30132

Drop Vs-c Effic. % % %


30 28 32 30 25 25 24 23 19 19 16 16 11 11 12 13 13,5 15 12 13,5 9,5 12 7,8 9,8 6,4 8 61 62 69 71,5 76,5 79,5 83 83,5 84,5 86 88,5 90 91

Fuse
32 mA 32 mA 63 mA 80 mA 125 mA 160 mA 250 mA 315 mA 500 mA 800 mA 800 mA 1,0 A 1,25 A

Format
EI 38 x 13,6 EI 42 x 14,8 EI 48 x 16,8 EI 54 x 18,4 EI 60 x 21 EI 66 x 23 EI 66 x 34,7 EI 78 x 27,5 EI 84 x 29,5 EI 84 x 43,5 EI 96 x 35,7 EI 96 x 45,7 EI 96 x 59,7

F
19,5 17,8 9 11 12,2 13,3 7,4 7,6 10,2 10,8 10,6 10,6 10,2

3,5 3,5 3,5 3,5 4,8 4,8 4,8 5,2 5,5 5,5 5,5 5,2 5,5

61 33 65 33 75 39 82,5 43 88 48 94 49,5 94 61 112,5 59 120 64 120 78 133 75 133 85 133 98,5

35 51 38 55 43 62 12 48,5 68 11 53,5 75 13,5 58,5 82 13 58,5 82 37,5 71,5 97,5 32,5 75 102,5 32,5 75 102,5 45 85 115 40 85 115 50 85 115 64

ENCAPSULATED TRANSFORMERS

* Transformer not complying with the standard (for this, it must be equiped with a thermal fuse system)

25

FLF / FLC SERIES

FLYBACK TRANSFORMERS RANGE

for switch mode power supplies

MYRRA Part N

CORE SIZE

Max. Output Power Watts

Outputs Vdc nominal voltage


5v 5v 12v 3.3v 5v 24v 5v 5v 5v 3.3v 5v 24v 5v 3.3v 5v 5v 5v 12v 3.3v 5v 5v 12v 5v 12v 5v 12v 12v 5v 12v 12v 12v 12v 5v 5v 12v 5v 12v 5v 5v 5v 12v 18v 12v 12v 12v 30v 5v 12v 24v 15v 12v 12v 5v 12v 12v 12v 18v 30v 24v 12v

74000 74001 74002 74003 74010 74014 74015 74020 74021 74023 74030 74032 74040 74043 74050 74060 74070 74080 74081

E16 E16 E16 E16 E16 E16 E16 EL19 EL19 EL19 E25 E25 ETD29 ERL28 ETD34 ETD39 ETD44 EF20 EF20 EF20 E16 E16 E16 E16 E16 E16

5w 6w 6w 5w 12w 12w 12w 18w 18w 16w 30w 35w 60w 60w 90w 140w 180w 24w 20w 20w 1.5w 1.5w 3.1w 3.1w 9w 9w

POWER FERRITE TRANSFORMERS

74082 74090 74091 74092 74093 74094 74095

HIGH FREQUENCY FERRITE

Note : 5 volts outputs can generally be used for 3.3 to 6volts; 12 volts outputs can be used for 9 to 16volts. See detailed characteristics.

26

TRANSFORMER / CONTROL CIRCUITS

CROSS-REFERENCE LIST

Transformer Reference 74090 74091 74092 74093 74094 74095

IC Manufacturer

Series & References

No aux. Winding

PI

TNY Series LNK XT Series

ON Bright

HIGH FREQUENCY FERRITE

OB2535 OB2212 OB2361 etc.

27

POWER FERRITE TRANSFORMERS

74000 74001 74002 74003 74004 74005 74010 74014 74015 74020 74021 74023 74080 74081 74082 74087 74088 74089 74030 74032 74040 74043 74050 74060 74070

ONSEMI

NCP 1014 NCP 3065 etc. TOP Series LNK Series TEA1530 TEA1351 TEA3065 etc.

PI

NXP

With aux. Winding ST Viper Series

FAIRCHILD

FAN102 FAN400 FSEZ130 FSEZ1213 etc.

TRANSFORMER FOR TINYSWITCH

SIZE E16 SINGLE OUTPUT : 5 or 12v

Primary / Secondary Insulation 4000V Creepage distance Primary / Secondary 6mm Ambient temperature < 85C Construction conforms to IEC950, IEC335, IEC61558-2-16 for reinforced insulation Exclusively uses UL94-V0 listed materials

DRAIN +E

0V +S1

Bottom View (Pin side)

Pin 3 Removed PCB Drilling Diameter = 1.1mm

Windings MYRRA P/N Output Power maximum 1.5 w 1.5 w Pri S1 Pri S1 Current maximum 0.28 Apeak 0.4 Adc 0.28 Apeak 0.2 Adc 6000H Inductance (+/-10%) 6000H

Pins 10 9 52 10 9 52

Turns 228 16 228 28

Voltage 85 - 265Vrms 3.3 6 Vdc 85 - 265Vrms 7.5 15 Vdc

74090 74091

HIGH FREQUENCY FERRITE

POWER FERRITE TRANSFORMERS

Examples of application with Integrated Circuits : MYRRA P/N Control IC Manufacturer Power Integrations Power Integrations

Input voltage 85 - 265Vrms 85 - 265Vrms

Power 1.5w 1.5w

Frequency 44kHz 44kHz

74090 74091

28

TRANSFORMER FOR TINYSWITCH

SIZE E16 SINGLE OUTPUT : 5 or 12v

Primary / Secondary Insulation 4000V Creepage distance Primary / Secondary 6mm Ambient temperature < 70C Construction conforms to IEC950, IEC335, IEC61558-2-16 for reinforced insulation Exclusively uses UL94-V0 listed materials

DRAIN +E

0V +S1

Bottom View (Pin side)

Pin 3 Removed PCB Drilling Diameter = 1.1mm

Windings MYRRA P/N Output Power maximum 3.1 w 3.1 w Pri S1 74093 Pri S1 Current maximum 0.34 Apeak 0.9 Adc 0.34 Apeak 0.4 Adc 4200H Inductance (+/-10%) 4200H

Pins 10 9 52 10 9 52

Turns 191 13 191 24

Voltage 85 - 265Vrms 3.3 6 Vdc 85 - 265Vrms 7.5 15 Vdc

74092

Examples of application with Integrated Circuits : MYRRA P/N 74092 74093 Control IC Manufacturer Power Integrations Power Integrations

Input voltage 85 - 265Vrms 85 - 265Vrms

Power 3.1w 3.1w

Frequency 44kHz 44kHz

29

POWER FERRITE TRANSFORMERS

HIGH FREQUENCY FERRITE

TRANSFORMER FOR TINYSWITCH

SIZE E16 SINGLE OUTPUT : 5 or 12v

Primary / Secondary Insulation 4000V Creepage distance Primary / Secondary 6mm Ambient temperature < 60C Construction conforms to IEC950, IEC335, IEC61558-2-16 for reinforced insulation Exclusively uses UL94-V0 listed materials

DRAIN +E

0V +S1

Bottom View (Pin side)

Pin 3 Removed PCB Drilling Diameter = 1.1mm

Windings MYRRA P/N Output Power maximum 9w 9w Pri S1 74095 Pri S1 Current maximum 0.48 Apeak 1.5 Adc 0.48 Apeak 0.9 Adc 2100H Inductance (+/-10%) 2100H

Pins 10 9 52 10 9 52

Turns 135 9 135 17

Voltage 85 - 265Vrms 3.3 6 Vdc 85 - 265Vrms 7.5 15 Vdc

74094

POWER FERRITE TRANSFORMERS

Examples of application with Integrated Circuits : MYRRA P/N 74094 Control IC Manufacturer Power Integrations Power Integrations Power Integrations 74095 Power Integrations Power Integrations Power Integrations

HIGH FREQUENCY FERRITE

Input voltage 85 - 265Vrms 85 - 265Vrms 85 - 265Vrms 85 - 265Vrms 85 - 265Vrms 85 - 265Vrms

Power 4.2w 5w 9w 5w 5w 9w

Frequency 44kHz 132kHz 132kHz 44kHz 132kHz 132kHz

30

FLYBACK TRANSFORMER

2 OUTPUTS : 5 & 12v

Primary / Secondary Insulation 4000V Primary / Auxiliary Insulation 1500V Creepage distance Primary / Secondary 6mm Ambient temperature < 70C Construction conforms to IEC950, IEC335, IEC61558-2-16 for reinforced insulation Exclusively uses UL94-V0 listed materials

+E

DRAIN +AUX 0V

74000

+S2 0V +S1 0V

Bottom View (Pin side)

PIN 3 Removed PCB Drilling Diameter = 1.1mm

Windings MYRRA P/N Output Power maximum 5w Pri Aux S1 S2 Current maximum 0.27 Apeak 0.1 Adc 1.2 Adc 0.4 Adc Inductance (+/-10%) 3900H

Pins 4-6 2-1 9 - 10 7-8

Turns 138 16 8 19

Voltage 85 - 265Vrms 7 14 Vdc 3.3 7 Vdc 8 17 Vdc

74000

Examples of application with Integrated Circuits : MYRRA P/N 74000 Control IC Manufacturer Power Integrations ST Microelectronics

Input voltage 85 - 265Vrms 85 - 265Vrms

Power 5w 4w

Frequency 132kHz 70kHz

31

POWER FERRITE TRANSFORMERS

HIGH FREQUENCY FERRITE

FLYBACK TRANSFORMER

SIZE E16 SINGLE OUTPUT : 5 or 12v

Primary / Secondary Insulation 4000V Primary / Auxiliary Insulation 1500V Creepage distance Primary / Secondary 6mm Ambient temperature < 60C Construction conforms to IEC950, IEC335, IEC61558-2-16 for reinforced insulation Exclusively uses UL94-V0 listed materials

+E

DRAIN +AUX 0V

+S1 0V

Bottom View (Pin side)

PIN 3 Removed PCB Drilling Diameter = 1.1mm


Windings

MYRRA P/N

Output Power maximum 6w Pri Aux S1

Pins 4-6 2-1 9 - 10 4-6 2-1 9 - 10

Turns 138 20 8 150 22 24

Voltage 85 - 265Vrms 8 16 Vdc 3 6 Vdc 85 - 265Vrms 8.5 17 Vdc 9 18 Vdc

Current maximum 0.35 Apeak 0.1 Adc 1.2 Adc 0.38 Apeak 0.1 Adc 0.5 Adc

Inductance (+/-10%) 3000H

74001

74002

6w

Pri Aux S1

3000H

Examples of application with Integrated Circuits :

POWER FERRITE TRANSFORMERS

MYRRA P/N 74001

Control IC Manufacturer Power Integrations ST Microelectronics ST Microelectronics Motorola Infineon

Input voltage 85 - 265Vrms 85 - 265Vrms 85 - 265Vrms 85 - 265Vrms 185 - 265Vrms 85 - 265Vrms 85 - 265Vrms 85 - 265Vrms 85 - 265Vrms 185 - 265Vrms

Power 6w 6w 3w 6w 6w 6w 6w 3w 6w 6w

Frequency 132kHz 70kHz 40kHz 100kHz 100kHz 132kHz 70kHz 40kHz 100kHz 100kHz

HIGH FREQUENCY FERRITE

74002

Power Integrations ST Microelectronics ST Microelectronics Motorola Infineon

32

FLYBACK TRANSFORMER

SIZE E16 DUAL OUTPUT : 3.3 + 5v

Primary / Secondary Insulation 4000V Primary / Auxiliary Insulation 1500V Creepage distance Primary / Secondary 6mm Ambient temperature < 60C Construction conforms to IEC950, IEC335, IEC61558-2-16 for reinforced insulation Exclusively uses UL94-V0 listed materials

+E

DRAIN +AUX 0V

+S2 +S1 0V

74003

Bottom View (Pin side)

PIN 3 Removed PCB Drilling Diameter = 1.1mm

Windings MYRRA P/N Output Power maximum 6w Pri Aux S1 S2 Examples of application with Integrated Circuits : MYRRA P/N 74003 Control IC Manufacturer Power Integrations ST Microelectronics ST Microelectronics Motorola Infineon Current maximum 0.3 Apeak 0.1 Adc 1.8 Adc 1.2 Adc Inductance (+/-10%) 3000H

Pins 4-6 2-1 9 - 10 7 - 10

Turns 120 17 5 7

Voltage 85 - 265Vrms 8 16 Vdc 2 4 Vdc 3 6 Vdc

74003

Input voltage 85 - 265Vrms 85 - 265Vrms 85 - 265Vrms 85 - 265Vrms 185 - 265Vrms

Power 5w 6w 3w 6w 6w

Frequency 132kHz 70kHz 40kHz 100kHz 100kHz

33

POWER FERRITE TRANSFORMERS

HIGH FREQUENCY FERRITE

FLYBACK TRANSFORMER

SIZE E16 1 OUTPUT : 6v

Primary / Secondary Insulation 4000 V Primary / Auxiliary Insulation 1500 V Creepage distance Primary / Secondary 6mm Ambient temperature < 50C Construction conforms to IEC950, IEC335, IEC61558-2-16 for reinforced insulation Exclusively uses UL94 V-0 listed materials

Windings MYRRA P/N Output Power maximum 1.7 w Pri Aux S Current maximum 0.28 Apeak 0.1 Adc 0.5 Adc Inductance (+/-10%) 2700 H

Pins 1-2 5-4 7-6 NC - 2

Turns 108 25 8 8

Voltage 85 - 265Vrms 22 Vdc 6 Vdc

74004

POWER FERRITE TRANSFORMERS

Shield Examples of application with Integrated Circuits : MYRRA P/N 74004 Control IC Manufacturer Power Integrations Power integrations Power Integrations Power Integrations Power Integrations Power Integrations

HIGH FREQUENCY FERRITE

Control IC P/N LNK562 LNK562 LNK563 LNK563 LNK564 LNK564

Input voltage 185 - 265 Vrms 85 - 265 Vrms 185 - 265 Vrms 85 - 265 Vrms 185 - 265 Vrms 85 - 265 Vrms

Power 1.3 W 1.3 W 1.7 W 1.7 W 2.0 W 2.0 W

Frequency 66 kHz 66 kHz 83 kHz 83 kHz 100 kHz 100 kHz

Remarks : This transformer perfectly fulfils the specification of Power Integrations AN-39 Appendix - A.

34

FLYBACK TRANSFORMER

SIZE E16 1 OUTPUT : 10v

Primary / Secondary Insulation 4000 V Primary / Auxiliary Insulation 1500 V Creepage distance Primary / Secondary 6mm Ambient temperature < 50C Construction conforms to IEC950, IEC335, IEC61558-2-16 for reinforced insulation Exclusively uses UL94 V-0 listed materials

Windings MYRRA P/N Output Power maximum 1.7 w Aux S Shield Pri 5-4 7-6 NC - 2 Current maximum 0.28 Apeak Inductance (+/-10%) 2700 H

Pins 1-2 25 12 8

Turns 108 22 Vdc 10 Vdc

Voltage 85 - 265Vrms 0.1 Adc 0.2 Adc

74005

Examples of application with Integrated Circuits : MYRRA P/N 74005 Control IC Manufacturer Power Integrations Power integrations Power Integrations Power Integrations Power Integrations Power Integrations Control IC P/N LNK562 LNK562 LNK563 LNK563 LNK564 LNK564

Input voltage 185 - 265 Vrms 85 - 265 Vrms 185 - 265 Vrms 85 - 265 Vrms 185 - 265 Vrms 85 - 265 Vrms

Power 1.3 W 1.3 W 1.7 W 1.7 W 2.0 W 2.0 W

Frequency 66 kHz 66 kHz 83 kHz 83 kHz 100 kHz 100 kHz

Remarks : This transformer perfectly fulfils the specification of Power Integrations AN-39 Appendix - B.

35

POWER FERRITE TRANSFORMERS

HIGH FREQUENCY FERRITE

FLYBACK TRANSFORMER

SIZE E16 2 OUTPUTS : 5 & 12v

Primary / Secondary Insulation 4000V Primary / Auxiliary Insulation 1500V Creepage distance Primary / Secondary 6mm Ambient temperature < 50C Construction conforms to IEC950, IEC335, IEC61558-2-16 for reinforced insulation Exclusively uses UL94-V0 listed materials

+E

DRAIN +AUX 0V

74010

+S2 0V +S1 0V

Bottom View (Pin side)

PIN 3 Removed PCB Drilling Diameter = 1.1mm


Windings

MYRRA P/N

Output Power maximum 12 w Pri Aux S1 S2

Pins 4-6 2-1 9 - 10 7-8

Turns 120 14 7 17

Voltage 85 - 265Vrms 7 14 Vdc 3.3 7 Vdc 8 17 Vdc

Current maximum 0.55 Apeak 0.1 Adc 2 Adc 1 Adc

Inductance (+/-10%) 1660H

74010

Examples of application with Integrated Circuits : MYRRA P/N Control IC Manufacturer Power Integrations Power Integrations Power Integrations Power Integrations Power Integrations ST Microelectronics ST Microelectronics Motorola Motorola Infineon Infineon Fairchild Fairchild

Input voltage 185 - 265Vrms 85 - 265Vrms 185 - 265Vrms 85 - 265Vrms 185 - 265Vrms 85 - 265Vrms 185 - 265Vrms 85 - 265Vrms 185 - 265Vrms 92 - 265Vrms 185 - 265Vrms 85 - 265Vrms 185 - 265Vrms

Power 12w 10w 12w 10w 12w 8w 10w 8w 10w 7,5w 10w 7w 10w

Frequency 132kHz 132kHz 132kHz 132kHz 132kHz 70kHz 70kHz 100kHz 100kHz 100kHz 100kHz 50kHz 100kHz

HIGH FREQUENCY FERRITE

36

POWER FERRITE TRANSFORMERS

74010

FLYBACK TRANSFORMER

SIZE E16 2 OUTPUTS : 2 x 24v

Primary / Secondary Insulation 4000V Primary / Auxiliary Insulation 1500V Creepage distance Primary / Secondary 6mm Ambient temperature < 50C Construction conforms to IEC950, IEC335, IEC61558-2-16 for reinforced insulation Exclusively uses UL94-V0 listed materials

+E

DRAIN +AUX 0V

74014

+S2 0V +S1 0V

Bottom View (Pin side)

PIN 3 Removed PCB Drilling Diameter = 1.1mm

Windings MYRRA P/N Output Power maximum 12 w Pri Aux S1 S2 Typical outputs : Current maximum 0.5 Apeak 0.2 Adc 0.4 Adc 0.4 Adc Inductance (+/-10%) 1800H

Pins 4-6 2-1 9 - 10 7-8

Turns 120 17 27 27

Voltage 85 - 265Vrms 9 18 Vdc 15 30 Vdc 15 30 Vdc

74014

Examples of application with Integrated Circuits : MYRRA P/N 74014 Control IC Manufacturer Power Integrations Power Integrations Power Integrations Power Integrations

Input voltage 185 - 265Vrms 85 - 265Vrms 185 - 265Vrms 85 - 265Vrms

Power 12w 8w 12w 8w

Frequency

132kHz 132kHz

37

POWER FERRITE TRANSFORMERS

+24V 0.5A with S1 S2 in parallel +48V 0.25A with S1 S2 in series (8-9 connected) +15V / -15V 0.4A with pins 8-9 connected to 0V

HIGH FREQUENCY FERRITE

FLYBACK TRANSFORMER

SIZE E16 3 OUTPUTS : 5 / 15 / 24v

Primary / Secondary Insulation 4000V Primary / Auxiliary Insulation 1500V Creepage distance Primary / Secondary 6mm Ambient temperature < 50C Construction conforms to IEC950, IEC335, IEC61558-2-16 for reinforced insulation Exclusively uses UL94-V0 listed materials

+E

DRAIN +AUX 0V

74015

+S3 +S2 +S1 0V

Bottom View (Pin side)

PIN 3 Removed PCB Drilling Diameter = 1.1mm

Windings MYRRA P/N Output Power maximum 12 w Pri Aux S1 S2 S3 Current maximum 0.5 Apeak 0.2 Adc 1.5 Adc 0.6 Adc 0.4 Adc Inductance (+/-10%) 1800H

Pins 4-6 2-1 9 - 10 8 - 10 7 - 10

Turns 120 14 6 17 27

Voltage 85 - 265Vrms 12 Vdc 5 Vdc 15 Vdc 24 Vdc

74015

HIGH FREQUENCY FERRITE

POWER FERRITE TRANSFORMERS

Examples of application with Integrated Circuits : MYRRA P/N 74015 Control IC Manufacturer Power Integrations Power Integrations Power Integrations Power Integrations

Input voltage 185 - 265Vrms 85 - 265Vrms 185 - 265Vrms 85 - 265Vrms

Power 10w 8w 12w 9w

Frequency

132kHz 132kHz

38

FLYBACK TRANSFORMER

SIZE EL19 2 OUTPUTS : 5 & 12v

Primary / Secondary Insulation 4000V Primary / Auxiliary Insulation 1500V Creepage distance Primary / Secondary 6mm Ambient temperature < 50C Construction conforms to IEC950, IEC335, IEC61558-2-16 for reinforced insulation Exclusively uses UL94-V0 listed materials

DRAIN + AUX 0V

+S2 0V +S1 0V

74020 / 74021

Bottom View (Pin side) PCB Drilling Diameter = 1.1mm


Windings MYRRA P/N Output Power maximum 18 w Pri Aux S1 S2 74021 18 w Pri Aux S1 S2 Examples of application with Integrated Circuits : MYRRA P/N 74020 Control IC Manufacturer Power Integrations Power Integrations Power Integrations ST Microelectronics ST Microelectronics ST Microelectronics Motorola Infineon 74021 ST Microelectronics Motorola Infineon Input voltage 85 - 265Vrms 185 - 265Vrms 85 - 265Vrms 85 - 265Vrms 185 - 265Vrms 185 - 265Vrms 185 - 265Vrms 185 - 265Vrms 85 - 265Vrms 85 - 265Vrms 92 - 265Vrms Power 15w 18w 12w 10w 12w 16w 16w 16w 13w 13w 10w Frequency 132kHz 132kHz 132kHz 100kHz 100kHz 100kHz 100kHz 100kHz 70kHz 100kHz 100kHz Current maximum 0.8 Apeak 0.1 Adc 3 Adc 1.4 Adc 1.1 Apeak 0.1 Adc 3 Adc 1.4 Adc 900H Inductance (+/-10%) 1250H

Pins 4-6 2-1 9 - 10 7-8 4-6 2-1 9 - 10 7-8

Turns 108 12 6 14 108 12 6 14

Voltage 85 - 265Vrms 7 14 Vdc 3.3 7 Vdc 8 16.5 Vdc 85 - 265Vrms 7 14 Vdc 3.3 7 Vdc 8 16.5 Vdc

74020

39

POWER FERRITE TRANSFORMERS

HIGH FREQUENCY FERRITE

FLYBACK TRANSFORMER

SIZE EL19 5 OUTPUTS : 3.3 / 5 / 12 / 18 / 30v

Primary / Secondary Insulation 4000V Primary / Auxiliary Insulation 1500V Creepage distance Primary / Secondary 6mm Ambient temperature < 60C Construction conforms to IEC950, IEC335, IEC61558-2-16 for reinforced insulation Exclusively uses UL94-V0 listed materials

10

1 2 3 4 5 6

+S5 +S4 +S3 +S2 +S1 0V

DRAIN 9 +Aux 8 0v 7

74023

Bottom View (Pin side) PCB Drilling Diameter = 1.1mm

Windings MYRRA P/N Output Power maximum 16 w Pri Aux S1 S2 S3 S4 S5


Examples of application with Integrated Circuits : MYRRA P/N 74023 Control IC Manufacturer Power Integrations Power Integrations Input voltage 185 - 265Vrms 85 - 265Vrms Power 16w 12w Frequency 132kHz 132kHz

Pins 9 10 87 56 46 36 26 16

Turns 120 17 4 6 14 20 33

Voltage 85 - 265Vrms 15 Vdc 3.3 Vdc 5 Vdc 12 Vdc 18 Vdc 30 Vdc

Current maximum 0.85 Apeak 0.2 Adc S1 + S2 : 7 Adc S1 + S2 : 7 Adc 0.8 Adc 0.8 Adc 0.2 Adc

Inductance (+/-10%) 1250H

74023

HIGH FREQUENCY FERRITE

40

POWER FERRITE TRANSFORMERS

FLYBACK TRANSFORMER

SIZE EF20 2 or 3 OUTPUTS : 5/5v or 12/12v or 3.3+5/12v

Primary / Secondary Insulation 4000V Primary / Auxiliary Insulation 1500V Creepage distance Primary / Secondary 8mm Ambient temperature < 50C Construction conforms to IEC950, IEC335, IEC61558-2-16 for reinforced insulation Exclusively uses UL94-V0 listed materials
+E DRAIN +AUX 0V +S1 0V

+E

74087 - 74089

+S2 0V

DRAIN +AUX 0V

PIN 3 Removed PCB Drilling Diameter = 1.2mm

74088

+S2 +S1 0V +S3 0V

Windings MYRRA P/N Output Power maximum 24 w 74087 Pri Aux S1 S2 20 w 74088 Pri Aux S1 S2 S3 20 w 74089 Pri Aux S1 S2 Examples of application with Integrated Circuits : MYRRA P/N Control IC Manufacturer Power Integrations 74087 74088 Power Integrations Power Integrations Power Integrations Power Integrations 74089 Power Integrations Power Integrations Current maximum 1.0 Apeak 0.3 Adc 1.5 Adc 1.5 Adc 0.9 Apeak 0.3 Adc S1 + S2 : 7 Adc S1 + S2 : 7 Adc 1.3 Adc 0.85 Apeak 0.3 Adc 2.0 Adc 2.0 Adc 1300H 1100H Inductance (+/-10%) 1000H

Pins 45 21 67 9 10 45 21 78 68 9 10 45 21 67 9 10

Turns 86 12 10 10 80 17 4 6 14 86 12 5 5

Voltage 85 - 265Vrms 11 - 18 Vdc 9 15 Vdc 9 15 Vdc 85 - 265Vrms 15 Vdc 3.3 Vdc 5 Vdc 12 Vdc 85 - 265Vrms 7 - 18 Vdc 3 7.5 Vdc 3 7.5 Vdc

Input voltage 185 - 265Vrms 85 - 265Vrms 185 - 265Vrms 85 265Vrms 185 - 265Vrms 85 265Vrms 185 - 265Vrms

Power 24w 15w 20w 12w 20w 14w 17w

Frequency 132kHz 132kHz 132kHz 132kHz 132kHz 132kHz < 120kHz

41

POWER FERRITE TRANSFORMERS

HIGH FREQUENCY FERRITE

FLYBACK TRANSFORMER

SIZE E25 3 or 1 OUTPUTS : 5+12/12v or 24v

Primary / Secondary Insulation 4000V Primary / Auxiliary Insulation 1500V Creepage distance Primary / Secondary 6mm Ambient temperature < 50C Construction conforms to IEC950, IEC335, IEC61558-2-16 for reinforced insulation Exclusively uses UL94-V0 listed materials

+E

DRAIN +AUX 0V

74030

+S2 +S1 0V +S3 0V

+E

DRAIN +AUX 0V

+S1 0V

Bottom View (Pin side)

PIN 4 Removed PCB Drilling Diameter = 1.4mm


Windings

74032

MYRRA P/N

Output Power maximum 30 w Pri Aux S1 S2 S3

Pins 35 21 78 68 9 10 35 21 6 10

Turns 70 8 4 9 9 72 10 18

Voltage 85 - 265Vrms 7 14.5 Vdc 3.3 - 7 8 16 Vdc 8 16 Vdc 85 - 265Vrms 8 - 16 Vdc 15 - 30 Vdc

Current maximum 1.5 Apeak 1 Adc 3 Adc 1.5 Adc 1.5 Adc 1.1 Apeak 1 Adc 1.4 Adc

Inductance (+/-10%) 750H

74030

74032

35 w

Pri Aux S1

1100H

Note for 74030 : S2 and S3 can be connected in series or in parallel

POWER FERRITE TRANSFORMERS

Examples of application with Integrated Circuits : MYRRA P/N 74030 Control IC Manufacturer Power Integrations Power Integrations ST Microelectronics ST Microelectronics Motorola Motorola Infineon Fairchild 74032 Power Integrations Input voltage 185 - 265Vrms 85 - 265Vrms 85 - 265Vrms 185 - 265Vrms 85 - 265Vrms 185 - 265Vrms 185 - 265Vrms 85 - 265Vrms 185 - 265Vrms Power 30w 25w 22w 30w 22w 30w 30w 22w 25w Frequency 132kHz 66 or 132kHz 70kHz 70kHz 100kHz 100kHz 100kHz 100kHz 132kHz

HIGH FREQUENCY FERRITE

42

FLYBACK TRANSFORMER

SIZE ETD29 4 OUTPUTS : 5+12 / 5+12v

Primary / Secondary Insulation 4000V Primary / Auxiliary Insulation 1500V Creepage distance Primary / Secondary 8mm Ambient temperature < 50C Construction conforms to IEC950, IEC335, IEC61558-2-16 for reinforced insulation Exclusively uses UL94-V0 listed materials

+E

DRAIN +AUX 0V

+S4 +S3 0V +S2 +S1 0V

Bottom View (Pin side)

PIN 4 Removed PCB Drilling Diameter = 1.3mm

Windings MYRRA P/N Output Power maximum 60 w Pri Aux S1 S2 S3 S4 Current maximum 3.0 Apeak 0.5 Adc 4 Adc 2.5 Adc 4 Adc 2.5 Adc Inductance (+/-10%) 500H

Pins 57 32 12 13 11 13 9 10 8 - 10

Turns 50 6 3 7 3 7

Voltage 85 - 265Vrms 7 14.5 Vdc 3.3 - 7 8 16.5 Vdc 3.3 - 7 8 16.5 Vdc

74040

Note : S1 / S3 or S2 / S4 can be connected in series or in parallel Examples of application with Integrated Circuits : MYRRA P/N 74040 Control IC Manufacturer Power Integrations Power Integrations ST Microelectronics ST Microelectronics Motorola Motorola Infineon Infineon Input voltage 185 - 265Vrms 85 - 265Vrms 85 - 265Vrms 185 - 265Vrms 85 - 265Vrms 185 - 265Vrms 92 - 265Vrms 185 - 265Vrms Power 60w 45w 35w 45w 35w 45w 35w 45w Frequency 66 or 132kHz 66 or 132kHz 100kHz 100kHz 100kHz 100kHz 100kHz 100kHz

43

POWER FERRITE TRANSFORMERS

HIGH FREQUENCY FERRITE

FLYBACK TRANSFORMER

SIZE ERL28 5 OUTPUTS : 3.3 / 5 / 12 / 18 / 30v

Primary / Secondary Insulation 4000V Primary / Auxiliary Insulation 1500V Creepage distance Primary / Secondary 6mm Ambient temperature < 50C Construction conforms to IEC950, IEC335, IEC61558-2-16 for reinforced insulation Exclusively uses UL94-V0 listed materials

18 17 16 10 11

+30v +18v +5v(dc) +5v(ac) +12v

DRAIN 5 +Aux 8 0v 9

14,15 +3v3 12,13 0v

Bottom View (Pin side)

PCB Drilling Diameter = 1.3mm

Windings MYRRA P/N Output Power maximum 60w Pri Aux S1 S2 S3 S4 S5 Examples of application with Integrated Circuits : MYRRA P/N 74043 Control IC Manufacturer Power Integrations Power Integrations Input voltage 185 - 265Vrms 85 - 265Vrms Power 60w 45w Frequency 66 or 132kHz 66 or 132kHz Current maximum 3 Apeak 0.5 Adc S1+S2 : 7 Adc S1+S2 : 7 Adc 2 Adc 2 Adc 0.5 Adc Inductance (+/-10%) 500H

Pins 51 89 14+15 / 12+13 11 / 12+13 16 10 17 10 18 10

Turns 45 7 2 3 4 7 13

Voltage 85 - 265Vrms 15 Vdc 3.3 Vdc 5 Vdc 12 Vdc 18 Vdc 30 Vdc

74043

HIGH FREQUENCY FERRITE

44

POWER FERRITE TRANSFORMERS

FLYBACK TRANSFORMER

SIZE ETD34 4 OUTPUTS : 5+12 / 5+12v

Primary / Secondary Insulation 4000V Primary / Auxiliary Insulation 1500V Creepage distance Primary / Secondary 8mm Ambient temperature < 50C Construction conforms to IEC950, IEC335, IEC61558-2-16 for reinforced insulation Exclusively uses UL94-V0 listed materials

+E

DRAIN +AUX 0V

+S4 +S3 0V +S2 +S1 0V

Bottom View (Pin side)

PIN 4 Removed PCB Drilling Diameter = 1.5mm

Windings MYRRA P/N Output Power maximum 90 w Pri Aux S1 S2 S3 S4 Current maximum 2.8 Apeak 0.5 Adc 5 Adc 3 Adc 5 Adc 3 Adc Inductance (+/-10%) 500H

Pins 57 32 12 13 11 13 9 10 8 - 10

Turns 36 4 2 5 2 5

Voltage 85 - 265Vrms 7 14 Vdc 3.3 6.5 8.5 17 Vdc 3.3 6.5 8.5 17 Vdc

74050

Note : S1 / S3 or S2 / S4 can be connected in series or in parallel Examples of application with Integrated Circuits : MYRRA P/N 74050 Control IC Manufacturer Power Integrations Power Integrations ST Microelectronics ST Microelectronics Motorola Motorola Infineon Infineon Input voltage 185 - 265Vrms 85 - 265Vrms 185 - 265Vrms 85 - 265Vrms 185 - 265Vrms 85 - 265Vrms 185 - 265Vrms 85 - 265Vrms Power 90w 60w 80w 60w 80w 60w 80w 60w Frequency 132kHz 66 or 132kHz 70kHz 70kHz 100kHz 100kHz 100kHz 100kHz

45

POWER FERRITE TRANSFORMERS

HIGH FREQUENCY FERRITE

FLYBACK TRANSFORMER

SIZE ETD39 4 OUTPUTS : 5+12 / 5+12v

Primary / Secondary Insulation 4000V Primary / Auxiliary Insulation 1500V Creepage distance Primary / Secondary 8mm Ambient temperature < 50C Construction conforms to IEC950, IEC335, IEC61558-2-16 for reinforced insulation Exclusively uses UL94-V0 listed materials

+E

DRAIN +AUX 0V

+S4 +S3 0V +S2 +S1 0V

Bottom View (Pin side)

PIN 4 Removed PCB Drilling Diameter = 1.5mm

Windings MYRRA P/N Output Power maximum 140 w Pri Aux S1 S2 S3 S4 Current maximum 4 Apeak 0.5 Adc 5 Adc 5 Adc 5 Adc 5 Adc Inductance (+/-10%) 440H

Pins 57 32 14 15 13 15 11 12 10 12

Turns 36 4 2 5 2 5

Voltage 85 - 265Vrms 7 14 Vdc 3.3 6.5 8.5 17 Vdc 3.3 6.5 8.5 17 Vdc

74060

Note : S1 / S3 or S2 / S4 can be connected in series or in parallel Examples of application with Integrated Circuits :

POWER FERRITE TRANSFORMERS

MYRRA P/N 74060

Control IC Manufacturer Power Integrations Power Integrations ST Microelectronics ST Microelectronics Motorola Motorola Infineon Infineon Fairchild Fairchild

Input voltage 185 - 265Vrms 85 - 265Vrms 85 - 265Vrms 185 - 265Vrms 85 - 265Vrms 185 - 265Vrms 85 - 265Vrms 185 - 265Vrms 85 - 265Vrms 185 - 265Vrms

Power 140w 90w 70w 120w 70w 120w 70w 120w 70w 120w

Frequency 132kHz 66 or 132kHz 70kHz 100kHz 100kHz 100kHz 100kHz 100kHz 100kHz 100kHz

HIGH FREQUENCY FERRITE

46

FLYBACK TRANSFORMER

SIZE ETD44 4 OUTPUTS : 5+12 / 5+12v

Primary / Secondary Insulation 4000V Primary / Auxiliary Insulation 1500V Creepage distance Primary / Secondary 8mm Ambient temperature < 50C Construction conforms to IEC950, IEC335, IEC61558-2-16 for reinforced insulation Exclusively uses UL94-V0 listed materials

+E

DRAIN +AUX 0V

+S4 +S3 0V +S2 +S1 0V

Bottom View (Pin side)

PIN 4 Removed PCB Drilling Diameter = 1.5mm

Windings MYRRA P/N Output Power maximum 180 w Pri Aux S1 S2 S3 S4 Current maximum 8 Apeak 0.5 Adc 6 Adc 5 Adc 6 Adc 5 Adc Inductance (+/-10%) 300H

Pins 57 32 16 17 15 17 13 14 12 14

Turns 38 4 2 5 2 5

Voltage 85 - 265Vrms 7 14 Vdc 3.3 6.5 8.5 17 Vdc 3.3 6.5 8.5 17 Vdc

74070

Note : S1 / S3 or S2 / S4 can be connected in series or in parallel Examples of application with Integrated Circuits : MYRRA P/N 74070 Control IC Manufacturer Power Integrations Power Integrations Infineon Fairchild Philips Input voltage 185 - 265Vrms 85 - 265Vrms 185 - 265Vrms 185 - 265Vrms 185 - 265Vrms Power 180w 120w 160w 160w 120w Frequency 66 or 132kHz 66kHz 100kHz 100kHz 50kHz

47

POWER FERRITE TRANSFORMERS

HIGH FREQUENCY FERRITE

FLYBACK TRANSFORMER

1 TO 35 W FLYBACK TRANSFORMERS STANDARD SIZES

HIGH FREQUENCY FERRITE

48

POWER FERRITE TRANSFORMERS

COMMON MODE CHOKES RANGE FOR EMI SUPPRESSION

U9.8

U10.5

U16

E25

Mainly used to reduce noise conducted through power or signal lines. The common mode inductance filters symmetrical noise, associated with Y-type safety capacitors connected to ground. The differential mode inductance filters asymmetrical noise, associated with X-type capacitor connected between Line and Neutral.

MYRRA Part N

SIZE

Inductance range

Current range

74330 - 74335 74300 - 74306 74310 - 74315 74320 - 74325

U9.8 U10.5 U16 E25

1.5 to 47mH 1.5 to 68mH 1.5 to 33mH 1.5 to 33mH

0.18 to 1.1A 0.30 to 1.9A 0.75 to 3.3A 0.90 to 4.0A

Toroidal Common Mode Chokes - Custom design available upon request

49

CURRENT TRANSFORMERS RANGE

HIGH FREQUENCY FERRITE

COMMON MODE CHOKES FOR EMI SUPPRESSION

Ambient Temperature 50C Dielectric Strength 1.5 kV between windings Electrical characteristics at 25 C

SIZE : U9.8

ELECTRICAL CHARACTERISTICS :
MYRRA Part N Inductance Common Mode min - max (mH) 33 - 56 18 - 31 10 - 17 4.7 - 8 2.2 - 3.7 1 - 1.7 Rated Current Arms 0.18 0.26 0.35 0.5 0.8 1.1 Resistance per winding ohm max 7 3.5 2.0 .95 .4 .21 Inductance Differential Mode H min 710 360 210 100 45 20 Resonant Frequency kHz min 210 280 400 610 910 1300

74330 74331 74332 74333 74334 74335

MECHANICAL CHARACTERISTICS / PINOUT :

HIGH FREQUENCY FERRITE

CURRENT TRANSFORMERS RANGE

View from pin side PCB Drilling diameter 1.0 mm

50

COMMON MODE CHOKES FOR EMI SUPPRESSION

Ambient Temperature 50C Dielectric Strength 1.5 kV between windings Electrical characteristics at 25 C

SIZE : U10.5

ELECTRICAL CHARACTERISTICS :
MYRRA Part N 74306 74300 74301 74302 74303 74304 74305 Inductance Common Mode min - max (mH) 51 - 85 33 - 56 18 - 31 10 - 17 4.7 - 8 2.2 - 3.7 1 - 1.7 Rated Current Arms 0.3 0,35 0,45 0,6 0,9 1,3 1,9 Resistance per winding ohm max 4 3 1,7 1 0,43 0,23 0,1 Inductance Differential Mode H min 530 400 240 140 65 32 14 Resonant Frequency kHz min 125 170 220 320 480 740 1000

MECHANICAL CHARACTERISTICS / PINOUT :

View from pin side PCB Drilling diameter 1.1 mm

51

CURRENT TRANSFORMERS RANGE

HIGH FREQUENCY FERRITE

COMMON MODE CHOKES FOR EMI SUPPRESSION

Ambient Temperature 50C Dielectric Strength 1.5 kV between windings Electrical characteristics at 25 C

SIZE : U16

ELECTRICAL CHARACTERISTICS :
MYRRA Part N 74310 74311 74312 74313 74314 74315 Inductance Common Mode min - max (mH) 22 37 15 25 10 - 17 4.7 - 8 2.2 - 3.7 1 - 1.7 Rated Current Arms 0,75 0,9 1,1 1,5 2,3 3,3 Resistance per winding ohm max 1 0,75 0,44 0,24 0,095 0,046 Inductance Differential Mode H min 230 150 100 50 20 10 Resonant Frequency kHz min 170 210 280 440 650 1000

MECHANICAL CHARACTERISTICS / PINOUT :

HIGH FREQUENCY FERRITE

CURRENT TRANSFORMERS RANGE

View from pin side PCB Drilling diameter 1.1 mm

52

COMMON MODE CHOKES FOR EMI SUPPRESSION

Ambient Temperature 50C Dielectric Strength 1.5 kV between windings Electrical characteristics at 25 C

SIZE : E25

ELECTRICAL CHARACTERISTICS :
MYRRA Part N 74320 74321 74322 74323 74324 74325 Inductance Common Mode min - max (mH) 22 37 15 25 10 - 17 4.7 - 8 2.2 - 3.7 1 - 1.7 Rated Current Arms 0,9 1,1 1,3 1,8 2,7 4 Resistance per winding ohm max 0,54 0,35 0,22 0,105 0,05 0,03 Inductance Differential Mode H min 130 90 50 25 11 7 Resonant Frequency kHz min 170 210 270 400 630 950

MECHANICAL CHARACTERISTICS / PINOUT :

View from pin side PCB Drilling diameter 1.2 mm

53

CURRENT TRANSFORMERS RANGE

HIGH FREQUENCY FERRITE

DIMMER CHOKES FOR EMI SUPPRESSION

For noise suppression in light dimmers Saturable chokes : provides a high impedance for Triac switching interferences, and a low impedance for 50Hz component. Electrical characteristics at 25

ELECTRICAL CHARACTERISTICS :
Dimensions (mm) MYRRA Part N Power Inductance +/- 15 % Rated Current Resistance 1.5 Associated Capacitor OD max 24 29 32.5 38 44 50 58 ID min 9 10 9 14 14 12 10 H max 9.5 12 16 12 16.5 22.5 28 W max 0.5 0.7 0.9 0.9 1.2 1.8 2.5 Approx. Weight

74190 74191 74192 74196 74193 74194 74195

150 w 300 w 500 w 500 w 1000 w 2200 w 4500 w

3.5 mH 2.8 mH 2.0 mH 1.8 mH 1.3 mH 450 H 250 H

0.7 Arms 1.3 Arms 2.2 Arms 2.2 Arms 4.5 Arms 10 Arms 20 Arms

0.73 0.35 0.37 0.15 0.04

22 nF 47 nF 82 nF 82 nF 220 nF 470 nF 1 F

13 g 24 g 47 g 39 g 80 g 140 g 250 g

0.014

MECHANICAL CHARACTERISTICS :

HIGH FREQUENCY FERRITE

TOROIDAL CHOKES

L = 25 +/-10mm

54

CURRENT TRANSFORMERS RANGE

E13 U10.5

E19-V T15

E19-H T18

E25 T30

T40

FOR MAINS AC CURRENT MEASUREMENT - 50 to 400 Hz


MYRRA Part N 74521 74523 74531 74533 74534 74561 SIZE Ratio PIN PRIMARY - up to 25A
Size E19-H Size E19-V Size E25 Size E25 Size E25 Size U10.5 Ratio 1 / 1 / 750 Ratio 1 / 500 Ratio 1 / 1 / 1000 Ratio 1 / 1000 Ratio 1 / 350 Ratio 1 / 2000 Current 10 A / 20 A Current 15 A Current 12.5 A / 25 A Current 8 A Current 4 A Current 8 A

Current range

THRU-HOLE PRIMARY - up to 250A 74503 74504 74511 74543, 74544, 74545 74546, 74547, 74548
Size T18 Size T18 Size T30 Size T40 Size T40 Ratio 1 / 1000 Ratio 1 / 750 Ratio 1 / 1000 Ratio 1 / 500 Ratio 1 / 1000 Current 12 A Current 10 A Current 60 A Current 100 A Current 250 A

FOR SWITCH MODE POWER SUPPLIES - 20 to 150kHz


MYRRA Part N 74520 74530 74550 74560 74562 74570 SIZE Ratio PIN PRIMARY - up to 25A
Size E19-H Size E25 Size E13 Size U10.5 Size U10.5 Size T15 Ratio 1 / 1 / 100 Ratio 1 / 1 / 100 Ratio 1 / 100 Ratio 1 / 100 Ratio 1 / 100 Ratio 1 / 1 / 50 Current 10 A/ 20 A Current 12.5 A/ 25 A Current 10 A Current 10 A Current 10 A/ 20 A Current 10 A

Current range

THRU-HOLE PRIMARY - up to 200A 74500 74501 74502 74510 74540, 74541, 74542
Size T18 Size T18 Size T18 Size T30 Size T40 Ratio 1 / 50 Ratio 1 / 100 Ratio 1 / 200 Ratio 1 / 100 Ratio 1 / 100 Current 15 A Current 25 A Current 25 A Current 150 A Current 200 A

55

CURRENT TRANSFORMERS RANGE

HIGH FREQUENCY FERRITE

TOROIDAL / THRUHOLE

MYRRA Part N

Sec. Turns

Max Pri. Current A rms 15 A

Rsec. max 0.6

Lsec. mH min 5

Pulse Vsec x t max @ Frequency 175 V.S 20 200 kHz 350 V.S 20 100 kHz 700 V.S 20 100 kHz 2.5 V.ms 50 Hz 2.0 V.ms 50 Hz

Sine Vsec max @ Frequency 15 V 20 200 kHz 25 V 20 100 kHz 50 V 20 100 kHz 0.15V/ 50 Hz/ 12A 0.6V/ 50 Hz/ 8A 0.13V/ 50 Hz/ 10A 0.3V/ 50 Hz/ 5A

Typical Load/ Accuracy/ Current 50 / 1% / 15 A

74500

50

74501

100

25 A

1.5 5

20

74502

200

25 A

80

74503

1000

12 A

45 35

200 / 1% / 25 A

100 / 1% / 25 A

2000

74504

750

10 A

1100

10 / 2% / 10 A 40 / 2% / 5 A

10 / 2% / 12 A 40 / 2% / 8 A

Data applies for one primary turn (single passage of primary wire through toroid hole). Sensitivity can be increased for lower currents by winding more than one turn.
74500 / 74501 / 74502 74503 / 74504
18 max 10 max 3 12.7 1 21 max 3 1

CURRENT TRANSFORMERS RANGE

Primary Current Direction

HIGH FREQUENCY FERRITE

HOLE DIA 5 P

3 1

56

TOROIDAL / THRUHOLE

MYRRA Part N

Sec. Turns

Max Pri. Current A rms 150 A

Rsec. max 0.25 32

Lsec. mH min 40

Pulse Vsec x t max @ Frequency 1 V.ms/ 20 kHz 700 V s/ 100 kHz 10 V.ms/ 50 Hz

Sine Vsec max @ Frequency 50 V/ 20 kHz 80 V/ 100 kHz 0.6 V/ 50 Hz/ 60 A 1 V/ 50 Hz/ 40 A

Typical Load/ Accuracy/ Current 1 - 20 / 1%

74510

100

74511

1000

60 A

4000

10 / 1% / 60 A 20 / 1% / 40 A

Data applies for one primary turn (single passage of primary wire through toroid hole). Sensitivity can be increased for lower currents by winding more than one turn. Models with 50, 100, 200 turns are designed for switch-mode power conversion (up to 200 kHz). Models with 500 and 1000 turns are designed for Mains current measurement (50 to 400 Hz).

74510/ 74511

Primary current direction 7 2

10

Pin 8 removed for locating

HIGH FREQUENCY FERRITE

57

CURRENT TRANSFORMERS RANGE

PIN PRIMARY TYPES

FOR SWITCH MODE POWER SUPPLIES - 20 to 150 kHz


MYRRA Part N 74520 Ratio Max Pri. Current A rms 20 A parallel 10 A serie Rsec. max 1.5 Lsec. mH min 8 Pulse Vsec x t max 400 V.s Sine Vsec rms max 50 Vrms Typical Load/ Accuracy/ Current 10 100 / 1% / 10 A Insulation Voltage P/ S 2500 V

1/1/100

FOR MAINS AC CURRENT MEASUREMENT - 50 to 400 Hz


MYRRA Part N 74521 Ratio Max Pri. Current A rms 20 A parallel 10 A serie Rsec. max 57 Lsec. mH min Pulse Vsec x t max Sine Vsec rms max Typical Load/ Accuracy/ Current 75 / 4% / 20 A Insulation Voltage P/ S

1/1/750

300

15 V.ms

3 Vrms

2500 V

SAFETY : These products are only composed of UL approved materials. These products have a construction conform to CEI950, CEI335, CEI61558 for Basic insulation (3 mm creepage distance)

CURRENT TRANSFORMERS RANGE

74520/ 74521
1 P1 4 2 P2 3

HIGH FREQUENCY FERRITE

8 5

Pins 6 & 7 removed for locating

58

PIN PRIMARY TYPES

FOR MAINS AC CURRENT MEASUREMENT - 50 to 400 Hz


MYRRA Part N 74523 Ratio Max Pri. Current A rms 15 A Rsec. max 155 Lsec. mH min 670 Pulse Vsec x t max 30 V.ms Sine Vsec rms max 6 Vrms Typical Load/ Accuracy/ Current 50 / 2% / 15 A 200 / 5% / 10 A Insulation Voltage P/ S 1500 V

1/ 500

SAFETY : This product is only composed of UL approved materials. This product has a construction conform to CEI950, CEI335, CEI61558 for Functional insulation

74523
P 1 2

HIGH FREQUENCY FERRITE

Pins 6 & 7 removed for locating

59

CURRENT TRANSFORMERS RANGE

PIN PRIMARY TYPES

FOR SWITCH MODE POWER SUPPLIES - 20 to 150 kHz


MYRRA Part N 74530 Ratio Max Pri. Current A rms 25 A parallel 12.5 A serie Rsec. max 1 Lsec. mH min 10 Pulse Vsec x t max 600 V.s Sine Vsec rms max 80 Vrms Typical Load/ Accuracy/ Current 10 - 100 / 1%/ 25 A Insulation Voltage P/ S 2500 V

1/1/100

FOR MAINS AC CURRENT MEASUREMENT - 50 to 400 Hz


MYRRA Part N 74531 Ratio Max Pri. Current A rms 25 A parallel 12.5 A serie 8A Rsec. max 90 Lsec. mH min 4H Pulse Vsec x t max 8 V.ms Sine Vsec rms max 1.6 Vrms Typical Load/ Accuracy/ Current 50 / 2% / 20 A Insulation Voltage P/ S 2500 V

1/1/1000

74533

1/ 1000

360

17 H

15 V.ms

3 Vrms

200 / 1% / 8 A 500 / 1.5% / 5 A 100 / 1% / 4 A 500 / 1% / 2 A

2500 V

74534

1/ 350

4A

380

19 H

15 V.ms

3 Vrms

2500 V

SAFETY : These products are only composed of UL approved materials. These products have a construction conform to CEI950, CEI335, CEI61558 for Basic insulation (3 mm creepage distance)
74530/ 74531

CURRENT TRANSFORMERS RANGE

HIGH FREQUENCY FERRITE

10 P1 6 9 P2 7 9 7

2 4

74533/ 74534

2 4

Pins 1 & 8 removed for locating

60

TOROIDAL / THRUHOLE

MYRRA Part N 74540

Sec. Turns 100

Max Pri. Current A rms 200 A

0.35 6.5 22

Rsec. max

Lsec. mH min 50

Pulse Vsec x t max @ Frequency 2 V.ms/ 20 kHz 1 V.ms/ 100 kHz 10 V.ms/ 50 Hz

Sine Vsec max @ Frequency 150 V/ 20 kHz 150 V/ 100 kHz 0.7 V/ 50Hz/ 100 A 1.2 V/ 50Hz/ 60 A 15 V/ 50 Hz/ 250 A

Typical Load/ Accuracy/ Current 1..20 / 1%

74543

500

100 A

1250

74546

1000

250 A

8000

100 V.ms/ 50 Hz

50 / 1% / 250 A

3 / 1% / 100 A 10 / 1% / 60 A

Data applies for one primary turn (single passage of primary wire through toroid hole). Sensitivity can be increased for lower currents by winding more than one turn.

74540/ 74543/ 74546 Pin type (for PCB)

0.6 x 0.95
P

2 1

Primary Current Direction

61

CURRENT TRANSFORMERS RANGE

HIGH FREQUENCY FERRITE

TOROIDAL / THRUHOLE

MYRRA Part N 74541

Sec. Turns 100

Max Pri. Current A rms 200 A

0.35 6.5 22

Rsec. max

Lsec. mH min 50

Pulse Vsec x t max @ Frequency 2 V.ms/ 20 kHz 1 V.ms/ 100 kHz 10 V.ms/ 50 Hz

Sine Vsec max @ Frequency 150 V/ 20 kHz 150 V/ 100 kHz 0.7 V/ 50Hz/ 100 A 1.2 V/ 50Hz/ 60 A 15 V/ 50 Hz/ 250 A

Typical Load/ Accuracy/ Current 1..20 / 1%

74544

500

100 A

1250

74547

1000

250 A

8000

100 V.ms/ 50 Hz

50 / 1% / 250 A

3 / 1% / 100 A 10 / 1% / 60 A

Data applies for one primary turn (single passage of primary wire through toroid hole). Sensitivity can be increased for lower currents by winding more than one turn.

74541/ 74544/ 74547 FASTON Connectors (4.8 x 0.8)


P

2 1

CURRENT TRANSFORMERS RANGE

HIGH FREQUENCY FERRITE

Primary Current Direction

62

TOROIDAL / THRUHOLE

MYRRA Part N 74542

Sec. Turns 100

Max Pri. Current A rms 200 A

0.35 6.5 22

Rsec. max

Lsec. mH min 50

Pulse Vsec x t max @ Frequency 2 V.ms/ 20 kHz 1 V.ms/ 100 kHz 10 V.ms/ 50 Hz

Sine Vsec max @ Frequency 150 V/ 20 kHz 150 V/ 100 kHz 0.7 V/ 50Hz/ 100 A 1.2 V/ 50Hz/ 60 A 15 V/ 50 Hz/ 250 A

Typical Load/ Accuracy/ Current 1..20 / 1%

74545

500

100 A

1250

74548

1000

250 A

8000

100 V.ms/ 50 Hz

50 / 1% / 250 A

3 / 1% / 100 A 10 / 1% / 60 A

Data applies for one primary turn (single passage of primary wire through toroid hole). Sensitivity can be increased for lower currents by winding more than one turn.
74542/ 74545/ 74548 Wires type
P

2 1

Primary current Direction

Wires Length 250 1 = Black 0.5 mm2 2 = Red 0.5 mm2

10 mm

63

CURRENT TRANSFORMERS RANGE

HIGH FREQUENCY FERRITE

PIN PRIMARY TYPES

FOR SWITCH MODE POWER SUPPLIES - 20 to 150 kHz


MYRRA Part N Ratio Max Pri. Current A rms 10 Rsec. max 2.3 Lsec. mH min 6 Pulse Vsec x t max 250 V.s Sine Vsec rms max 40 Vrms Typical Load/ Accuracy/ Current 10 100 / 1% / 10 A Insulation Voltage P/ S 1500 V

74550

1/ 100

SAFETY : This product is only composed of UL approved materials. This product has a construction conform to CEI950, CEI335, CEI61558 for functional insulation

74550
P 1 2

4 3

HIGH FREQUENCY FERRITE

64

CURRENT TRANSFORMERS RANGE

PIN PRIMARY TYPES

FOR SWITCH MODE POWER SUPPLIES - 20 to 150 kHz


MYRRA Part N Ratio Max Pri. Current A rms 10 Rsec. max 1.1 Lsec. mH min 12 Pulse Vsec x t max 300 V.s Sine Vsec rms max 25 Vrms Typical Load/ Accuracy/ Current 5 50 / 1% / 10 A Insulation Voltage P/ S 4000 V

74560

1/ 100

74562

1/ 100

25

1.1

12

300 V.s

25 Vrms

5 50 / 1% / 25 A

4000 V

FOR MAINS AC CURRENT MEASUREMENT - 50 to 400 Hz


MYRRA Part N Ratio Max Pri. Current A rms 8A Rsec. max 400 Lsec. mH min 4.5 H Pulse Vsec x t max 5 V.ms Sine Vsec rms max 1 Vrms Typical Load/ Accuracy/ Current 100 / 2% / 6 A Insulation Voltage P/ S 4000 V

74561

1/ 2000

SAFETY : These products are only composed of UL approved materials. These products have a construction conform to CEI950, CEI335, CEI61558 for Reinforced insulation 74560, 74561 : 8 mm creepage distance 74562 : 6 mm creepage distance
74560/ 74561
P 1 2

74562
P 2 5

1 6

HIGH FREQUENCY FERRITE

65

CURRENT TRANSFORMERS RANGE

PIN PRIMARY TYPES

FOR SWITCH MODE POWER SUPPLIES - 20 to 150 kHz


MYRRA Part N 74570 Ratio Max Pri. Current A rms 20 A parallel 10 A serie Rsec. max 0.32 Lsec. mH min 9 Pulse Vsec x t max 150 V.s Sine Vsec rms max 12 Vrms Typical Load/ Accuracy/ Current 5 25 / 1% / 20 A Insulation Voltage P/ S 4000 V

1/1/50

SAFETY : This product is only composed of UL approved materials. This product has a construction conform to CEI950, CEI335, CEI61558 for Reinforced insulation (8 mm creepage distance)

74570
3 P1 6 4 P2 5 1 8

CURRENT TRANSFORMERS RANGE

Pins 2 & 7 removed for locating

HIGH FREQUENCY FERRITE

66

PULSE TRANSFORMERS RANGE

E13 EEM12.7

E19-V

E16 T10 T15

E19-H

E25 T25

To be used for MOSFET or IGBT Drive, SCR triggering, DC/DC power conversion, Voltage isolation.

MYRRA Part N
74600 74610 74611 74620 74621 74630 74631 74640 74641 74650 74710 74660 74661 74670

SIZE
Size T15 Size T25 Size T25 Size E19-H Size E19-H Size E25 Size E25 Size E19-V Size E19-V Size E13 Size E16 Size EEM12.7 Size EEM12.7 Size T10

Ratio
Ratio 1 / 1 / 1 Ratio 1 / 1 / 1 Ratio 1 / 1 / 1 Ratio 1 / 1 / 1 Ratio 3 / 1 / 1 Ratio 1 / 1 / 1 Ratio 3 / 1 / 1 Ratio 1 / 5 Ratio 1 / 10 Ratio 1 / 1 / 1 Ratio 1 / 1 Ratio 1CT / 1.3CT Ratio 1CT / 1CT Ratio 1CT / 1.3 Low stray inductance Low stray inductance Low stray inductance Low coupling capacitance Low coupling capacitance Low coupling capacitance Low coupling capacitance For voltage step-up Small size SMD SMD, for DC/DC converter SMD, Low stray inductance For voltage step-up Low coupling capacitance

67

PULSE TRANSFORMERS RANGE

HIGH FREQUENCY FERRITE

PULSE TRANSFORMERS

TOROID TYPES

74600

74610 74611

MYRRA Part N

Ratio P/S1/S2

L pri. +/-30%

Current / winding Arms max 0.6 1.7 1.2

Resistance / winding max 0.35 0.07 0.14

Pulse Ext V.s max 150 V.s 150 V.s 300 V.s

square V / kHz max 0.4 0.4 0.8

C P/S pF max 120 pF 35 pF 90 pF

Lleak P/S max 1.0 H 0.6 H 1.2 H

Insulation Voltage P/ S 4 kV 4 kV 4 kV S1/S2 4 kV 4 kV 4 kV

74600 74610 74611

1/1/1 1/1/1 1/1/1

48 0.6 1.2 2.5 - 5

Toroid core gives best coupling, lowest leakage inductance, fast rise time. Pulse (E.t rating) is given for bipolar (symetrical) pulse. Value is reduced for unipolar pulse. SAFETY : These products are only composed of UL-V0 approved materials. Insulation test voltage : 4000 Vrms This product has a construction conform to CEI950, CEI335, CEI61558 for Reinforced insulation (8 mm creepage distance)

74600

Size T15
3 PRI 1 8 4 6 5

S1

S2

Pins 2 & 7 removed for locating

PCB drill @ 1.1mm

Weight

6g

74610 - 74611

Size T25
6 PRI 4 2 7 9 10

HIGH FREQUENCY FERRITE

PULSE TRANSFORMERS

S1

S2

Pin 8 removed for locating

PCB drill @ 1.3mm

Weight

18 g

68

PULSE TRANSFORMERS

E19-H / E25 TYPES

74620 74621

74630 74631

MYRRA Part N

Ratio P/S1/S2

L pri. +/-30%

Current / winding Arms max 0.5 0.3 1 0.45

Resistance / winding max 1.0 2.0 0.4 0.8

Pulse Ext V.s max 350 V.s 800 V.s 500 V.s 1000 V.s

square V / kHz max 0.6 1.5 0.8 1.7

C P/S pF max 5 pF 5 pF 7 pF 7 pF

Lleak P/S max 70 H 400 H 60 H 300 H

Insulation Voltage P/ S 2.5 kV 2.5 kV 2.5 kV 2.5 kV S1/S2 1.5 kV 1.5 kV 1.5 kV 1.5 kV

74620 74621 74630 74631

1/1/1 3/1/1 1/1/1 3/1/1

3.2 mH 17 mH 2 mH 10 mH

Principally dedicated to SCR triggering Designed for minimum coupling capacitance SAFETY : These products are only composed of UL-V0 approved materials.
74620 - 74621 Size E19-H
3 PRI 2

5 6 7 8

S1 S2

Pin 1 removed for locating

74630 74631

Size E25

Weight

12 g

S2 10

Pins 1 & 8 removed for locating

Weight

20 g

69

PULSE TRANSFORMERS

4 PRI

HIGH FREQUENCY FERRITE

S1

LOW FREQUENCY PULSE TRANSFORMERS for voltage step-up

MYRRA Part N 74640 74641

Ratio P/S 1/5 1 / 10

L pri. +/-30% 11 mH 11 mH

Current Arms max Pri : 0.5 Sec : 0.1 Pri : 0.4 Sec : 0.04

Resistance max Pri : 1.0 Sec : 31 Pri : 1.8 Sec : 80

Pulse Vsec . t max 16 V.ms 33 V.ms

Sine Vsec. max 4 Vrms / 50 Hz 50 Vrms / 5 kHz 8 Vrms / 50 Hz 100 Vrms / 5 kHz

Insulation Voltage P/ S 1500 1500

SAFETY : These products are only composed of UL-V0 approved materials.

74640-74641

Size E19-V
1 PRI 2

6 SEC 4 14 g

HIGH FREQUENCY FERRITE

70

PULSE TRANSFORMERS

Pins 3 & 5 removed for locating

Weight

PULSE TRANSFORMERS

E13 - E16

74650

74710

MYRRA Part N

Ratio P/S1/S2

L pri.

Current / winding Arms max 0.6 0.6

Resistance / winding max 0.28 0.6

Pulse Ext V.s max 120 V.s 300 V.s

square V / kHz max 20V/ 100kHz 50V/ 100kHz

C P/S pF max 12 pF 6 pF

Lleak P/S max 2 H 44 H

Insulation Voltage P/ S 1.5 kV 4 kV S1/S2 1.5 kV

74650 74710

1/1/1 1/1

500 H +/-30% 2 mH +/-40%

74650 is principally designed for Mosfet drive in SMPS (Forward or Bridge converters) 74710 is principally designed for SCR Triggering SAFETY : These products are only composed of UL-V0 approved materials. The product 74710 has a construction conform to CEI950, CEI335, CEI61558 for Reinforced insulation (8 mm creepage distance)
74650 Size E13
4 PRI 2

6 7 9

S1

Pin 8 removed for locating

HIGH FREQUENCY FERRITE

3 1

4 6

Weight

8g

71

PULSE TRANSFORMERS

74710

Size E16

Weight

4g

S2 10

PULSE TRANSFORMERS

SMD TYPES

74660 - 74661

74670

MYRRA Part N

Ratio P/S

L pri.

Current / winding max 0.2 Arms 3 Apeak 0.5 Arms 0.4 Arms

Resistance / winding max 0.9 0.2 0.25

Pulse E x t max P1 or P2 50 V.s 30 V.s 15 V.s

square V / kHz max P1 or P2 15V 100 500kHz 0.05 V / kHz 100 400kHz 0.03 V / kHz 100 500kHz

C P/S pF max 20 pF 20 pF 12 pF

Lleak P/S max 0.35 H 0.2 H 0.4 H

Insulation Voltage P/ S 0.5 kV 0.5 kV 4 kV

74660 74661 74670

1+1 / 1.3+1.3 1+1 / 1+1 1+1 /1.3

240 H +/-30% 10 H +/-10% 220 H +/-30%

74660 can be used in association with MAXIM MAX250 or MAX253 74661 can be used in association with LINEAR TECHNOLOGY LT1424 74660 can be used in association with MAXIM MAX845 SAFETY : These products are only composed of UL-V0 approved materials.
74660 74661 Size EEM12.7
P1 P2

1 2 3 4

8 7 6 5

S1 S2

74670

Size T10

We ight

3g

HIGH FREQUENCY FERRITE

PULSE TRANSFORMERS

P1 P2 We ight 4g

1 2 4

7 9

SEC

72

POWER LINE COMMUNICATION COUPLING TRANSFORMERS

74710 - 74716 - 74717

74711

74712

74713

74714 - 74715

Designed for coupling signals to power line Adapted for use with Modem Circuits : ST7537, ST7538, TDA5051 or IC/SS

MYRRA Part N

Inductance ( H )

Leakage Inductance ( H )

Resistance per winding P / S (max) 0.2 / 0.2 0.06 / 0.1

Frequency range

Turns ratio P/S

Max Sec. current (mA rms) (50 - 60 Hz)

Insulation (Vrms)

Size

74714

1300 +/-40 % (2 4) 3.0 +/-25 % (7 9)

< 0.5

10 200kHz

1/1

5500

T10SMD T10SMD

74715

< 0.1

1 20 MHz

2 / 1+1

200

4000

74714 - 74715 Reinforced insulation, creepage distance > 8 mm


2 PRI 4

74714

9 S

74715
7 PRI 9

1 2 4

S2 S1

73

POWER LINE COMMUNICATION

HIGH FREQUENCY FERRITE

POWER LINE COMMUNICATION COUPLING TRANSFORMERS

MYRRA Part N

Inductance ( H )

Leakage Inductance ( H )

Resistance per winding P / S (max) 0.6 / 0.6 1 / 1 12 / 14 0.3 / 0.5

Frequency range

Turns ratio P/S

Max Sec. current (mA rms) (50 - 60 Hz)

Insulation (Vrms)

Size

74710

2000 +/-40 % (1 3) 2900 +/-40% (1 2) 45000 +/- 40 % (3 - 1) 400 +/- 40 % (3 - 1)

44 +/-7%

10 450kHz

1/1

10

4000

EF16H-4P U9.84P EF 16 H - 5P EF 16 H - 5P

74711

44 +/-7%

10 200kHz

1/1

1500

74716

1500 +/-10 % 14.4 +/- 10 %

10 - 200kHz

1/1.15

4000

74717

20 - 450kHz

1/1.67

40

4000

74710 - 74711 - 74716 74717 Typical application :


Designed for resonance of series coupling capacitor and the transformer leakage inductance. MYRRA Part N 74710 74711 74716 74717 Series Resonance Frequency (kHz) 132.5 132.5 50 40 - 90

Cc Mains Modem

Mains Coupling capacitance (nF) 33 33 6.8 470

74710 Reinforced insulation, creepage distance > 8 mm


3 P 1
o

4 S 6

74711 Functional insulation

POWER LINE COMMUNICATION

2 P 1

3 S 4

HIGH FREQUENCY FERRITE

74716 - 74717 Reinforced insulation, creepage distance > 8 mm


3 P 1
o

4 S 6

74

POWER LINE COMMUNICATION COUPLING TRANSFORMERS

MYRRA Part N

Inductance ( H )

Leakage Inductance ( H )

Resistance per winding P / S (max) 0.8 / 0.04 0.5 / 0.5

Frequency range

Turns ratio P/S

Max Sec. current (mA rms) (50 - 60 Hz)

Insulation (Vrms)

Size

74712

212 +/-10 % (2 5) 144 +/-10 % (2 5)

<5 (2 5) <5

10kHz 1MHz

5+1 / 1

500

4000

E16-V10P E13-V10P

74713

10 450kHz

5+1 / 5+1

200

1500

74712 - 74713 Typical application :


Designed for resonance of parallel capacitor with the primary magnetizing inductance.

Cc

Cp

Mains Modem

MYRRA Part N 74712 74713

Parallels Resonance Frequency ( kHz ) 132.5 132.5

Mains Coupling capacitor(nF) 33 33

Parallel capacitor ( nF ) 6.8 10

74712 Reinforced insulation, creepage distance > 6 mm


2 S 4 5 9 8 P

74713 Functional insulation

P 4 5 9

10

75

POWER LINE COMMUNICATION

HIGH FREQUENCY FERRITE

47000 SERIES - ELECTRONIC TRANSFORMERS

MYRRA encapsulated electronic transformers are Switched Mode Power Supplies based on Flyback topology. They constitute an interesting alternative to the traditional supply in the most common applications of power lower than 5W. ENERGY SAVING due to high efficiency and low standby power The applications for the Electronic serie are : Alternative to the linear transformers in all AC/DC applications of power up to than 5W Alternative to DC/DC converters for application in D.C.current (Telecom supplies, electric substations etc.) Industrial, domestic and consumer electronics applications Standby devices and others DC or AC auxiliary supplies With the same footprint as a EI30 transformer, they will replace: - 50 Hz Transformer - Fuse - Bridge Rectifier - Filtering Capacitor Regulated types will also replace linear regulator and heatsink

MAIN FEATURES Wide input voltage range Increased power. 3 x compared to standard EI30 transformer Better energetic efficiency : 70% typical compared to 40% for the conventional supply Very low Standby Power consumption: meets requirements of Energy Star or EC Code of Conduct Same footprint as EI30 transformer : Upgrade your application without redesign of PCB SAFETY STANDARDS APPROVALS: EN 60950 EN 60335 EN 61558-1 EN 61558-2-16 UL 60950-1 CSA 22.2 N60950-1 UL 94V0 EMC STANDARDS Conducted and radiated emissions conform to EN 55014-1 EN 55022 class B Immunity conform to EN 55014-2 EN 61000-4-x

ELECTRONIC TRANSFORMERS

76

47000 SERIES

ONE OUTPUT

2.5 & 5W

Regulated

ELECTRICAL SPECIFICATIONS Input voltage range 85 to 265 Volts AC 85 to 370 Volts DC Input Frequency 47 to 440 Hz Output voltage accuracy (full load ) 2% Line output voltage variation 0.3% Load output voltage variation 0.5% No load input power < 200mW Energy consumption and efficiency : Meets requirements of Energy Star and EC Code of Conduct

SAFETY Prepared for Class II reinforced insulation Input / Output Isolation test voltage: 4000 Vac Operating ambient temperature: - 25C / + Ta (See table) Storage temperature: - 40C / + 85C Input protection by integrated fusible resistor Output short circuit protection: automatic restarts when fault condition is removed Thermal shutdown with automatic recovery if internal temperature exceeds allowable value

Reference 47121 47122 47123 47124 47125 47126 47151 47152 47153 47154 47155 47156

Output voltage (DC Volts) 3.3 5 9 12 15 24 3.3 5 9 12 15 24

Output current (DC mA) 750 550 270 210 170 110 1350 900 550 420 320 220

Output Power (W) 2.5 2.75 2.5 2.5 2.5 2.5 4.2 4.5 5 5 5 5

Efficiency (%) 65 68 72 74 75 77 65 68 72 75 76 79

Ta (C) +70 +70 +70

+70 +70 +50 +50 +50 +50 +50 +50

ELECTRONIC TRANSFORMERS

DIMENSIONS and PINOUT 4 pins pins 1 & 5 : AC or DC Input pin 7: DC output +V pin 9: DC output 0V

77

47000 SERIES

ONE OUTPUT

+70

2.5 & 5 W

Regulated

ONE OUTPUT

3.2 & 5W

Non Regulated

ONE OUTPUT 3.2 & 5 W Non Regulated

ELECTRICAL SPECIFICATIONS Input voltage range 85 to 265 Volts AC 85 to 370 Volts DC Input Frequency 47 to 440 Hz Output voltage accuracy (full load) 5% Line output voltage variation 3% Load output voltage variation 0/ +30% No load input power < 300mW

SAFETY Prepared for Class II reinforced insulation Input / Output Isolation test voltage: 4000 Vac Operating ambient temperature: - 25C / + Ta (See table) Storage temperature: - 40C / + 85C Input protection by integrated fusible resistor Output short circuit protection: automatic restarts when fault condition is removed Thermal shutdown with automatic recovery if internal temperature exceeds allowable value

Reference 47114 47133 47134 47136 47163 47164 47166

Output voltage (DC Volts) 12 9 12 24 9 12 24

Output current (DC mA) 200 360 270 130 560 420 210

Output Power (W) 2.4 3.2 3.2 3.2 5* 5* 5*

Efficiency (%) 74 73 75 80 73 75 80

Ta (C) +70 +70 +70 +70 +50 +50 +50

* Nota: Power up to 5.4W is possible with input voltage 97 Vac

DIMENSIONS and PINOUT 4 pins pins 1 & 5 : AC or DC Input pin 7: DC output +V pin 9: DC output 0V

ELECTRONIC TRANSFORMERS

78

47000 SERIES

TWO OUTPUTS COMMON & ISOLATED

3 to 5W

Regulated

ELECTRICAL SPECIFICATIONS Input voltage range 85 to 265Volts AC 85 to 370V DC Input Frequency 47 to 440 Hz Output voltage accuracy : see table for 10 to 100% rated load of each output (includes line and load variations) No load input power < 200mW Energy consumption and efficiency : Meets requirements of Energy Star or EC Code of Conduct The 2 outputs share a common 0v reference. This enables closer coupling and a better cross-regulation of the outputs

SAFETY Prepared for Class II reinforced insulation Operating ambient temperature: - 25C / + Ta (See table) Storage temperature: - 40C / + 85C Input protection by integrated fusible resistor Output short circuit protection: automatic restarts when fault condition is removed Thermal shutdown with automatic recovery if internal temperature exceeds allowable value

COMMON OUTPUT
Reference 47243 47244 47245 47246 47247 Output 1 Output 2 (DC Volts) +10.5 +7 + 15 +7 +12 +5.5 +5 +12 +15 -15 Output 1 Output 2 (DC mA) 380 max 100 max 300 max 70 max 130 max 300 max 400 (600max) 170 max 130 max 130 max Output Power (W) 4* 4* 3.2 4 4 Output 1 Output 2 accuracy 3% +15% 3% 15% 5% 10% 3% 15% 8% 8% Efficiency (%) 72 73 65 65 73 Ta (C) +60 +60 +70 +60 +60

* Nota: Power up to 5W is possible with input voltage 97 Vac and Ta 50C

ISOLATED OUTPUT
Reference 47252 47254 47255 47257 47258 Output 1 Output 2 (DC Volts) 5 5 12 12 15 15 5 12 18 8 Output 1 Output 2 (DC mA) 350 (600max) 350 max 165 (300max) 165 max 135 (200max) 135 max 400 (600max) 170 max 150 (200max) 150 max Output Power (W) 3.5 4 4 4 4 Output 1 Output 2 accuracy 3% +15% 5% 15% 5% 15% 3% 15% 5% 15% Efficiency (%) 66 72 73 68 72 Ta (C) +60 +60 +60 +60 +60

COMMON OUTPUT
Input / Output Isolation test voltage: 4000 Vac

ISOLATED OUTPUT ELECTRONIC TRANSFORMERS


Input / Output Isolation test voltage: 4000 Vac Output1 / Output 2 isolation : 4000Vac

DIMENSIONS and PINOUT 5 pins pins 1 & 5 : AC or DC Input pin 6: Common output 0V pin 7: DC output 1 pin 10: DC output 2

DIMENSIONS and PINOUT 6 pins pins 1 & 5 : AC or DC Input pin 6: DC output1 0V pin 7: DC output1 +V pin 9: DC output2 0V pin 10: DC output2 +V

79

47000 SERIES

TWO OUTPUTS COMMON & ISOLATED 3 to 5 W Regulated

www.myrra.com
MYRRA S.A.S. : 2 Boulevard de la Haye - Parc Gustave Eiffel - 77600 Bussy St Georges - FRANCE Tel : +33 (0)1 60 37 55 55 - Fax : +33 (0)1 60 17 12 00 America : contact.usa@myrra.com Asia : contact.hong-kong@myrra.com Europe : contact.europe@myrra.com

Você também pode gostar