Escolar Documentos
Profissional Documentos
Cultura Documentos
Varispeed L7
The Liftdrive
Three control methods: Close loop current vector control, Sensorless current vector control, V/F control. High rated output current at high carrier frequency Direct control of motor brake and contactors Dedicated lift sequence built-in Emergency evacuation (battery operation) Short floor operation Door opening signal Stand still auto-tuning PLC Option Fieldbus options: DeviceNet, CANOpen, ProfiBus CE, UL, and cUL marking
Ratings
200 V Class three-phase 3.7 to 55 KW 400 V Class three-phase 4.0 to 55 KW
System Configuration
Special Accessories
Line Filter
Braking Accessories
R S T
Power Supply Three-phase, 200 V AC (200-V class) Three-phase, 400 V AC (400-V class)
Varispeed CIMR-L7
Monitor Cards
Communication Cards
JP3
T1
U6
C3
C33
U7
R11
C26 R6
U10
C28
R28
R113
U8
R1 R2
U10
+ + U9
C1
JP1
R70
Y1
+
R7
TR2
U1
R120
R8
R55
R52
C2
R75 R114
PE
C16
R131
U14
C35
C39
C22
+
2
TR1
C24 U11
C17 R14
C5 R20 R30
+
R99
R78
R6
D6
R95
U12
U15
C11
R10 R10
R105
R102
C12
JP5 C13 JP6 R95 RT4 U13
U17
CODE No.
SI-N 7360 C10 0-C0 210
Varispeed L7
Frequency Inverters
Specifications
Type Designation
CIMR L7 Z 4 0P4 0
Inverter L7 series Protective Enclosure 0: Open chassis type (IP00) 1: Enclosed type (NEMA1 / IP20) 7: Enclosed type (IP20) Specifications Z: European standard specifications Voltage 2: 200 V class 4: 400 V class Max. Applicable Motor Output 3P7: 3.7 kW 055: 55 kW "P" indicates a decimal point
200 V Class
Model CIMR-L7ZZ Max. apllicable motor output1 Output characteristics kW 23P7 25P5 27P5 2011 2015 2018 2022 2030 30 54 130 2037 37 67 160 2045 45 76 183 2055 55 93 224
3.7 7 17.5
5.5 10 25
7.5 14 33
11 20 49
15 27 64
18.5 33 80
22 40 96
Inverter Capacity kVA Rated Current Max. Voltage Max. output Frequency Rated Input Voltage and Frequency A
3-phase; 200, 208, 220, 230, or 240 VAC Up to 120Hz available by programing. 3-phase, 200/208/220/230/240 VAC, 50/60 Hz 21 25 40 52 68 96 + 10%, - 15% 5% Optional Not possible Built In Possible 115
156 176 220 269
Power Supply
The maximum applicable motor output is given for a standard 4-pole Yaskawa motor. When selecting the actual motor and Inverter, be sure that the Inverters rated current is applicable for the motors rated current. A transformer with dual star-delta secondary is required on the power supply for 12-pulse rectification.
400 V Class
Model CIMR-L7ZZ Max. apllicable motor output1 Output characteristics kW 44P0 4.0 9 11 45P5 5.5 12 14 47P5 7.5 15 18 4011 11 22 27 4015 15 28 34 4018 18.5 34 41 4022 22 40 48 4030 30 54 65 4037 37 67 80 4045 45 80 96 4055 55 106 128
Inverter Capacity kVA Rated Current Max. Voltage Max. output Frequency Rated Input Voltage and Frequency A
3-phase; 380, 400, 415, 440, 460, or 480 VAC (Proportional to input voltage.) 120 Hz max. 3-phase, 380, 400, 415, 440, 460 or 480 VAC, 50/60 Hz
13.2 17 22 32 41 49 58 78 96 115 154
Power Supply
The maximum applicable motor output is given for a standard 4-pole Yaskawa motor. When selecting the actual motor and Inverter, be sure that the Inverters rated current is applicable for the motors rated current. A transformer with dual star-delta secondary is required on the power supply for 12-pulse rectification.
Frequency Inverters
Enclosures
400V Class 200V Class Model CIMR-L7Z Enclosed Type (IEC IP20) Open Chassis Type (IEC IP00) Model CIMR-F7Z Enclosed Type (IEC IP20) Open Chassis Type (IEC IP00) 20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 Available as standard Available by removing the upper and lower cover of enclosed type 40P4 40P7 41P5 42P2 43P7 45P5 47P5 4011 4015 Available as standard 4018 4022 4030 4037 4045 4055
Commom Specifications
Model Number CIMR-L7Z Control method Carrier frequency Specification
Speed control response Torque limits Torque accuracy Frequency range Frequency accuracy (temperature characteristics) Frequency setting resolution Output frequency resolution Overload capacity and maximum current Frequency setting signal Accel/Decel time
Sine wave PWM Closed Loop Vector control, Open Loop Vector control, V/f control 8 kHz higher carrier frequency possible with current derating. 1:40 (V/f control) 1:100 (Open Loop Vector control) 1:1000 (Closed Loop Vector control) 3% (V/f control) 0.2% (Open Loop Vector control) 0.02% (Closed Loop Vector control) (25C 10C) 5 Hz (control without PG) 30 Hz (contorl with PG) Provided (4 quadrant steps can be changed by constant settings.) (Vector control) 5% 0.01 to 120 Hz Digital references: 0.01% (-10C to +40C) Analog references: 0.1% (25C 10C) Digital references: 0.01 Hz Analog references: 0.025/50 Hz (11 bits plus sign) 0.01 Hz 150% of rated output current for 30 sec. 0 to +10V 0.01 to 600.00 s (4 selectable combinations of independent acceleration and deceleration time settings) Overtorque/undertorque detection, torque limits, 8-speed control (maximum), 4 acceleration and deceleration times, S-curve acceleration/deceleration, auto-tuning (rotational or stationary), dwell function, cooling fan ON/OFF control, slip compensation, torque compensation, auto-restart after fault, DC braking for starting and stopping,A fault reset and parameter copy function, special Lift functions and sequences, short floor, hardware baseblock Protection by electronic thermal overload relay. Stops at approx. 200% of rated output current. Stops for fuse blown. OL2 fault at 150% of rated output current for 30 sec 200 Class Inverter: Stops when main-circuit DC voltage is above 410 V. 400 Class Inverter: Stops when main-circuit DC voltage is above 820 V. 200 Class Inverter: Stops when main-circuit DC voltage is below 190 V. 400 Class Inverter: Stops when main-circuit DC voltage is below 380 V. Protection by thermistor. Stall prevention during acceleration, deceleration and running independently. Protection by electronic circuits. Glows when the main circuit DC voltage is approx. 10 VDC or more. Enclosed wall-mounted type (IP20) : All models Enclosed wall-mounted type (NEMA 1): 18.5 kW or less (same for 200 V and 400 V class Inverters) Open chassis type (IP00): 22 kW or more (same for 200 V and 400 V class Inverters) -10C to 45C 95% max. (with no condensation) - 20C to + 60C (short-term temperature during transportation) Indoor (no corrosive gas, dust, etc.) 1000 m max. 10 to 20 Hz, 9.8 m/s2 max.; 20 to 50 Hz, 2 m/s2 max
Control characteristics
Protective functions
Motor protection Instantaneous overcurrent protection Fuse blown protection Overload protection Overvoltage protection Undervoltage protection Cooling fin overheating Stall prevention Grounding protection Charge indicator Protective structure Ambient operating temperature Ambient operating humidity Storage temperature Application site Altitude Vibration
Varispeed L7
Environment
Frequency Inverters
Specifications
Dimensions
Open Chassis Type (IEC IP00)
W1 4-d
H1
(5)
(5)
(5)
T1 D1 D
H2
Voltage
Max. Applicable Motor Output kW 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55
Inverter CIMRL7Z ---------------------2030 0 2037 0 2045 0 2055 0 ------------------4022 0 4030 0 4037 0 4045 0 4055 0
Dimensions in mm W1 H1 H2
D1
T1
Use the enclosed type (IP20) removing the upper and botton cover
7.5 12.5
2.3 3.2
M6 M10
24 57 63 86
Fan cooled
Use the enclosed type (IP20) removing the upper and botton cover
275 325
450 550
258 283
220 260
21 36
H1 T1 H2
H1
H1
H0
H0
H0 H
H2
H3
(5)
(5)
H10
H2
D1
W1
D1
H3
T1 4
T1 D1 (5) D
Fig 1
Fig 2
Fig 3
Voltage
Max. Applicable Motor Output kW 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55
Inverter CIMR-L7Z 23P7 7 25P5 7 27P5 7 2011 7 2015 7 2018 7 2022 7 2030 11 2037 11 2045 11 2055 11 44P0 7 45P5 7 47P5 7 4011 7 4015 7 4018 7 4022 7 4030 7 4037 7 4045 7 4055 7
Fig W 1 140 200 2 240 254 279 3 380 453 1 140 200 2 240 275 3 325 715 283 260 350 535 207 258 216 220 H 280 300 310 350 380 464 615 809 1027 280 300 D 177 197 207 258 298 328 348 177 197 W1 126 186 216 195 220 250 325 126 186
Dimensions in mm H0 H1 H2 280 300 350 400 450 600 725 280 300 350 450 550 266 285 335 385 435 575 700 266 285 335 435 535 7.5 7 8 7.5 7 8
T1 5
d M5
2.3
M6
11 24 27 62 68 94 4 6 10
12.5
3.2 5
M10 M5
Fan cooled
24 40
1.
Frequency Inverters
Standard Connections
DC reactor to improve input power factor (optional) Magnetic Contactor Short-circuit Bar (+1) L1 3-phase power 380 to 480V L2 50/60Hz L3 PE Line Filter L1 (R) L2 (S) L3 (T) (+2) ()
B1
Motor
IM/PM
Forward run/stop Reverse run/stop Nominal speed Inspection Run Multi-function Inputs (Factory setting) Internediate speed Leveling speed Not used Hardware baseblock
S1 S2 S3 S4 S5 S6 S7
TA1
PG
PG-X2 (Optional)
P P
TA3 BB +24 V 8 mA TA2 A Pulse SC IP24V (24V) CN5 (NPN setting) E (G) B Pulse Z Pulse Pulse Monitor Output RS-422 Level (100m or less wiring)
MA +V Frequency setting power +15V 20mA A1 Master speed reference 0 to 10V AC 0V MB MC M1 M2 Brake Command (Factory setting) Multi-fanction Contact Output 250VAC 1A or less 30VDC 1A or less Fault contact Output 250VAC 1A or less 30VDC 1A or less
Note: 1.Main circuit terminals are indicatied with double circles and control circuit terminals are indicatied with a single circles 2.The output current capacity of the +V terminal is 20mA 3.Sequence input signal S1 to S7 and BB are labelled for sequence connections for no-voltage contacts or NPN transistors as the default setting.
Shielded wires
Twisted-pair wires
Varispeed L7
Frequency Inverters
Installation
Installation
Main Circuit
Voltage Model CIMR-L7Z Max. Applicable Motor Output R/L1 S/L2 T/L3 R1/L11 S1/L21 T1/L31 U/T1 V/T2 W/T3 B1 B2 1 2 3 r / l1 / l2 PO NO Inverter output Braking resistor unit DC reactor ( 1- 2) ------Cooling fan power supply
200 V 20P4 to 2018 2022 and 2030 0.4 to 18.5 kW 22 and 30 kW Main circuit input power supply
2037 to 2055 37 to 55 kW
Main circuit input power supply R-R1, S-S1 and T-T1 have been wired before shipment.
400 V 40P4 to 4018 4022 to 4055 0.4 to 18.5 kW 22 to 55 kW Main circuit input Main circuit input power supply power supply R-R1, S-S1 and TT1 have been wired before shipment Inverter output
---
---
------
------
Braking unit ( 3- )
Braking unit ( 3- )
R/L1
CIMR L7Z2022,2030
200V Class
S/L2 T/L3 R1/L11 S1/L21 T1/L31 /l1 Power Supply Control Circuit
N0
P0
N0 P0
N0
P0
400V Class
+ +2 R/L1 S/L2 T/L3 Power Supply Control Circuit U/T1 V/T2 W/T3
N0
P0
N0
P0
Frequency Inverters
Control Circuit
Type Digital input signals No. S1 S2 S3 S4 S5 S6 S7 BB SC +V A1 AC E(G) Signal Name Forward run/stop command Reverse run/stop command Nominal speed Inspection run Intermediate speed Leveling speed Not used Hardware baseblock Digital input common 15 V power output Frequency reference Analog reference neutral Shield wire, optional ground line connection point Brake command (1NO contact) Contactor Control (1NO contact) Inverter Ready (1NO contact) Fault output signal (SPDT) (1 Change over contact) Function Signal Level Forward run when ON; stopped when OFF. Reverse run when ON; stopped when OFF. Nominal speed when ON. 24 VDC, 8 mA Inspection RUN when ON. Functions are selected Photo-coupler Internediate speed when ON. by setting H1-01 to H105. Leveling speed when ON. 15 V 15 V power supply for analog references (Max. current: 20 mA) 0 to +10 V/100% 0 to +10 V(20 k)
M1 M2 M3 M4 M5 M6 MA MB MC
Brake command when ON. Multi-function contact outputs Relay contacts Contact capacity: 1 A max. at 250 VAC 1 A max. at 30 VDC
Fault when CLOSED across MA and MC Fault when OPEN across MB and MC
When driving a reactive load, such as relay coil with DC power supply, always insert a flywheel diode
Varispeed L7
Frequency Inverters
Installation
Installation
Remove the upper and lower covers for the models of 15 kW or less in 200 V and 400 V classes. When using open chassis type inverters of 200 V/400 V 22 kW or more, secure spaces for eyebolts and wiring of the main circuit.
Internal Heatsink Upper Cover 55 C Upper Part Air Temperature 10 to 55 C Heatsink Open Chassis Type Inverter
Upper Cover
50 mm or more 120 mm or more Air
Heatsink
Side Spaces
400 V Class
Inverter Capacity Rated Current Heat Loss W Fin Inside Unit Total Heat Loss Fin Coding Model CIMR-L7Z kVA A W W W 44P0 5.8 7.6 91 70 161 45P5 9.5 12.5 127 82 209 47P5 13 17 193 114 307 4011 18 24 252 158 410 4015 24 31 326 172 498 4018 30 39 426 208 634 Fan cooled 4022 34 45 466 259 725 4030 46 60 678 317 995 4037 57 75 784 360 1144 4045 69 91 901 415 1316 4055 85 112 1203 495 1698
Frequency Inverters
Model CIMR-L7Z_ 23P7 25P5 27P5 2011 2015 2018 40P4 45P5 47P5 4011 4015 4018
Dimensions in mm W1 H1 D1 D2 126 180 216 126 180 216 290 122.6 57.4 316 136.1 63.4 372 133.6 76.4 290 122.6 57.4 316 136.1 63.4 372 133.6 76.4
D3 60 70 85 60 70 85
W1 W
H1 H
D1
D2 D3 or more
138 271 M5 197 298 233 353 M6 244 369 269 419 359 545 434 673 138 271 M5 197 298 233 353 269 419 309 519 M6 M10
4-d Tap
a a
(H2)
(H3)
(H2)
4-d Tap
(H3)
H1
H1 H
(W3)
(H2)
(W2)
(W2)
W1 W
(H3)
W1 W
Drawing 1
Drawing 2
Varispeed L7
(H3)
(H2)
Frequency Inverters
Installation
Ordering Information
System Configuration
Special Accessories CN1
Line filter
Braking Accessories
R S T
Power Supply Three-phase, 200 V AC (200-V class) Three-phase, 400 V AC (400-V class)
Varispeed CIMR-L7
T1
U6
C3
C33
U7
R11
C26 R6
U10
C28
R28
R113
R8
U8
Y1
+
R7
TR2
U1
R120
R1 R2
U10
+ + U9
C1
JP1
R55
R52
C2
R75 R114
PE
C16
R131
U14
R20 R30
C35
C39
C22
+
2
TR1
C24 U11
C17 R14
C5
+
R99
R78
R6
D6
R95
U12
U15
C11
R102
C12
JP5 C13 JP6 R95 RT4 U13
R10 R10
R105
U17
CODE No.
SI-N 7360 C10 0-C0 210
A Input Filters
200 V
Inverter Model Varispeed L7 CIMR-L7Z23P7 CIMR-L7Z25P5 CIMR-L7Z27P5 CIMR-L7Z2011 CIMR-L7Z2015 CIMR-L7Z2018 CIMR-L7Z2022 CIMR-L7Z2030 CIMR-L7Z2037 CIMR-L7Z2045 CIMR-L7Z2055 Type 3G3RV-PFI2035-SE 3G3RV-PFI2060-SE 3G3RV-PFI2100-SE 3G3RV-PFI2130-SE 3G3RV-PFI2160-SE 3G3RV-PFI2200-SE Line Filters EN55011 Class B, 25 m A 100 m B, 25 m A 100 m B, 25 m A 100 m A, 100 m A, 100 m A, 100 m Current (A) 35 60 100 130 160 200 Weight (kg) 1.4 3 4.9 4.3 6.0 11.0 Dimensions WxDxH 141x46x330 206x60x355 236x80x408 90x180x366 120x170x451 130x240x610
400 V
Inverter Model Varispeed L7 CIMR-L7Z44P0 CIMR-L7Z45P5 CIMR-L7Z47P5 CIMR-L7Z4011 CIMR-L7Z4015 CIMR-L7Z4018 CIMR-L7Z4022 CIMR-L7Z4030 CIMR-L7Z4037 CIMR-L7Z4045 CIMR-L7Z4055 Type 3G3RV-PFI3018-SE 3G3RV-PFI3035-SE 3G3RV-PFI3060-SE 3G3RV-PFI3070-SE Line Filters EN55011 Class B, 25 m A 100 m B, 25 m A 100 m B, 25 m A 100 m A, 100 m Current (A) 18 35 60 70 Weight (kg) 1.3 2.1 4.0 3.4 Dimensions WxDxH 141x46x330 206x50x355 236x65x408 80x185x329
3G3RV-PFI3130-SE
A, 100 m
130
4.7
90x180x366
10
Frequency Inverters
Name
Description
DO-08 / 3G3IV-PDO08
Function Outputs isolated type digital signal for monitoring inverter run state (alarm signal, zero speed detection etc.) . Output channel: Photo coupler 6 channels (48 V, 50 mA or less) Relay contact output 2 channels (250 VAC, 1 A or less 30 VDC, 1 A or less) Two multi-function contact outputs (2C-relay) can be used other than those of the inverter proper unit. Phase A pulse (single pulse) inputs (voltage, complementary, open collector input) PG frequency range: Approx. 30 kHz max. [ Power supply output for PG: +12 V, max. current 200 mA ] Pulse monitor output: +12 V, 20 mA
PG-B2 / 3G3FV-PPGB2
Phase A and B pulse inputs (exclusively for complementary input) PG frequency range: Approx. 30 kHz max. [ Power supply output for PG: +12 V, Max. current 200 mA] Pulse monitor output: Open collector, +24 V, Max. current 30 mA
PG-D2 / 3G3FV-PPGD2
Phase A pulse (differential pulse) input for V/f control (RS-422 input) PG Speed Controller Card PG frequency range: Approx. 300 kHz max. [ Power supply output for PG: +5 V or +12 V, (Used for V/f control with PG or Max. current 200 mA] Flux Vector) Pulse monitor output: RS-422
PG-X2 / 3G3FV-PPGX2
Phase A, B and Z pulse (differential pulse) inputs (RS-422 input) PG frequency range: Approx. 300 kHz max. [ Power supply output for PG: +5 V or +12 V, Max. current 200 mA] Pulse monitor output: RS-422
PG-F2
3G3RV-PDRT2
JP3
U6
C3
U7
R11
C26 R6
U10
C28
R28
R113
U8
R1 R2
U10
+ + U9
C1
R70
Y1
+
R7
TR2
U1
R120
R8
R55
R52
C2
R75 R114
PE
C16
R131
U14
C35
C39
C22
+
2
TR1
C24 U11
C17 R14
R78
R6
D6
C5 R20 R30
R95
R99
U12
Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through DeviceNet communication with the host controller.
T1
C33
JP1
U15
C11
R10 R10
R10
R102
C12
JP5 JP6 R95 RT4 U13 C13
U17
COD E No.
SI-N 736 00C10
C02 10
SI-P1
SI-S1
Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through Profibus-DP communication with the host controller. Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through CANopen communication with the host controller. Used for HVAC control, running or stopping the inverter, setting or referencing parameters, and monitoring output current, watt-hours, or similar items through LONWORKS communications with peripheral devices. 2 channel high resolution analog input card Channel 1: 0 to 10 V (20K) Channel 2: 4 to 20 mA (250) Resolution 14 bit 3 Channel high resolution analog input card Signal level: -10 to +10V (20 K) 4 to 20 mA (250 ) Resolution: 13 bit + sign 8 bit digital speed reference input card 16 bit digital speed reference input card Full PLC features, wireless installation and seamless access to the inverter parameters and analogue/digital inputs and outputs. Embedded Compubus/S fieldbus Standard Omron tools can be used for programming Same features than standard models with DeviceNet support.
SI-J
AI-14U / 3G3IV-PAI14U Analog input card AI-14B / 3G3IV-PAI14B DI-08 / 3G3IV-PDI08 DI-16H2 / 3G3IV-PDI16H2 3G3RV-P10CDT-E
PLC option
Varispeed L7
11
Frequency Inverters
Ordering Information
Ordering Information
G Accessories
Name JVOP-160-OY Description Installation
Panel Cutout
5 lines LCD digital operator 7 Language support
57 2-M3 MTG Holes
Panel
Digital operator
JVOP-161-OY
120
120 111
14.5
44 Through Hole 70
2.5
70
20
15.8
6.4 (60)
Panel Cutout installation Accessories Digital operator extension cable 1 meter 3 meters PC configuration cable Computer software Configuration and monitoring software tool
---------
12
Frequency Inverters
Max. Voltage Applicable Motor output kW 3.7 5.5 7.5 11 15 200 V 18.5 Class 22 30 37 45 55 4.0 5.5 7.5 11 15 400 V 18.5 Class 22 30 37 45 55 1. 2. 3. 4. 5.
Model CIMRL7Z_ 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 44P0 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055
Model No. of Model Resis- No. of CDBR_ used ERF-150WJ_ tance used 620 Built-in 62 1
Model LKEB_ 23P7 25P5 27P5 2011 2015 2015 2022 2015 2015 2022 2022 44P0 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4030
Specifications No. of of Resistor used 390 W 520 W 780 W 2400 W 3000 W 3000 W 4800 W 3000 W 3000 W 4800 W 4800 W 390 W 520 W 780 W 1040 W 1560 W 4800 W 4800 W 6000 W 9600 W 9600 W 6000 W 40 30 20 13.6 10 10 6.8 10 10 6.8 6.8 150 100 75 50 40 32 27.2 20 16 13.6 20 1 1 1 1 1 1 1 2 2 2 2 1 1 1 1 1 1 1 1 1 1 2
Braking torque % 125 115 125 125 125 125 125 125 100 120 100 135 135 130 135 125 125 125 125 125 125 135
1 2 2 2 2
---
---
201 Built in
200
110
1 1 1 1 2
---
---
Connectable Min Resistance Value 16 16 9.6 9.6 9.6 9.6 6.4 9.6 9.6 6.4 6.4 32 32 32 20 20 19.2 19.2 19.2 12.8 12.8 19.2
When connecting a mounting type resistor or braking resistor unit, set system constant L3-04 to 0 (stall prevention disabled during deceleration). If operating without changing the constant, motor does not stop at set deceleration time. When connecting mounting type braking resistor, set system constant L8-01 to 1 (braking resistor protection enabled). Load factor during deceleration to stop a load with constant torque. With constant output or continuous regenerative braking, the load factor is smaller than the specified value. Resistance value per one braking unit. Slect a resistance value that is larger than connectable minimum resistance value to obtain enough braking torque. For an application with large regenerative power such as hoisting, the braking torque or other items may exceed the capacity of a braking unit with a braking resistor in a standard combination (an result in capacity overload). Contact your Omron representatives when the braking torque or any other item exceeds the values in the table.
Braking Resistor
MCCB 3-phase Power Supply Motor
Set constant L8-01 to 1 (mounting type braking resistor protection enabled). Set sequence to shutt off the power side at inverter fault contact output.
Braking Unit 1
Cooling Fin Overheat Contact (Thermoswitch Contact) Cooling Fin Overheat Contact (Thermoswitch Contact)
Varispeed L7
13
Frequency Inverters
Ordering Information
Ordering Information
Braking unit
Model CDBR-2015 B, -2022 B, -4030B, -4045 B
100 or more 100 or more
72
66.5
138 38 30 or more 38
150
128 140
Mass 1.8 Kg
MTG Screw
150 or more
C 260
Dimensions in mm A 130 250 250 130 250 250 B 350 350 350 350 350 350 C 75 200 200 75 200 200 D 335 335 335 335 332 332 MTG Screw M5 x 4 M6 x 4 M6 x 4 M5 x 4 M6 x 4 M6 x 4
Voltage
220 V Class
400 V Class
Model LKEB-_ 2011 2015 2018 2022 4011 4015 4018 4022 4030 4037 4045
Dimensions in mm A 266 356 446 446 350 350 446 446 356 446 446 B 543 543 543 543 412 412 543 543 956 956 956 C 246 336 426 426 330 330 426 426 336 426 426 D 340 340 340 340 325 325 340 340 740 740 740 MTG Screw M8 x 4 M8 x 4 M8 x 4 M8 x 4 M6 x 4 M6 x 4 M8 x 4 M8 x 4 M8 x 4 M8 x 4 M8 x 4
Mass kg 10 15 19 19 16 18 19 19 25 33 33
14
Frequency Inverters
200 or more
50 or more
50 or more
200 or more
AC Reactor
When using low noise type inverters (high-carrier frequency of 2.5 kHz or more), do not connect an AC reactor to the output side (U, V, W) of the
200 V Class
Max. Applicable Motor Output kW 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55 Current Value A 20 30 40 60 80 90 120 160 200 240 280 Inductance mH 0.53 0.35 0.265 0.18 0.13 0.12 0.09 0.07 0.05 0.044 0.038 Code No. X 002491 X 002492 X 002493 X 002495 X 002497 X 002498 X 002555 X 002556 X 002557 X 002558 X 002559 Max. Applicable Motor Output kW 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55
400 V Class
Current Value A 10 15 20 30 40 50 60 80 90 120 150 Inductance mH 2.2 1.42 1.06 0.7 0.53 0.42 0.36 0.26 0.24 0.18 0.15 Code No. X 002500 X 002501 X 002502 X 002503 X 002504 X 002505 X 002506 X 002508 X 002509 X 002566 X 002567
DC Reactor
DC Reactor MCCB
Motor Power Supply Capacity (kVA) With Reactor for Power Supply Coordination Without Reactor
Varispeed L7
Take off the common bar between G1 and G2, and wire as shown in the diagram.
200 V Class
Max. Applicable Motor Output kW 4.0 5.5 7.5 11 15 18.5 22 to 55 Current Value A 18 36 72 90 Inductance mH 3 1 0.5 0.4 Built-in Code No. X010049 X010050 X010051 X010176 Max. Applicable Motor Output kW 4.0 5.5 7.5 11 15 18.5 22 to 55
400 V Class
Current Value A 12 23 33 47 Inductance mH 6.3 3.6 1.9 1.3 Built-in Code No. X010054 X010055 X010056 X010177
Varispeed L7
15
Frequency Inverters
Ordering Information
Ordering Information
Fuse installation
To protect the inverter, it is recommended to use semiconductor fuses like they are shown in the table below
Inverter Type
23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 43P7 44P0 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055
Voltage (V)
240 240 240 240 240 240 240 240 240 240 240 480 480 480 480 480 480 480 480 480 480 480 480
I2t (A2s)
82~220 220~610 290~1300 450~5000 1200~7200 1800~7200 870~16200 1500~23000 2100~19000 2700~55000 4000~55000 34~72 50~570 100~570 100~640 150~1300 400~1800 700~4100 240~5800 500~5800 750~5800 920~13000 1500~13000
16
Frequency Inverters