K61-SBM-20x2 HIRO+plus Geiger Counter

by Atomic.dave Atomic.Dave@yahoo.com
This is a one of a kind custom hand-made Geiger Counter built by Atomic.Dave. It is based on a kit designed by John Giametti (username: Brohogan) I have been building his DIY Geiger counters for over two years having built and sold around 60 of them. All information for this kit is available at the developers website. As I have said before, this is more of a kit for someone who knows a little bit about electronics but doesnt have the time or patience to build it, or would rather someone else do all the dirty work. Having been built by me, of course there will be some imperfections, although as minimal as possible. This particular one is a culmination of all of its predecessors. It is certainly one of my more advanced kits having more options then all accept the Cadillac, and I will do my best to explain how to use it. Once you have used it a couple times, it will be a piece of cake. OPERATION Four Triple Pole switches- ALL OFF IN CENTER POSITION. SELECT ALARM UP THRESHOLD MIDDLE TIMER DOWN POWER PWR/CHRG ON OFF CHARGE LIGHT LED/BKLT ON/ON OFF ON/OFF SOUND SPEAKER TONE OFF CLICK ALARM LED/SND ON/ON OFF ON/OFF NULL TONE RESET

A. SELECT switch does 2 things. When you first power on the unit, you will see first

Atomic.Dave K61 HIRO+plus V10.1


This customized first welcome window can easily be changed if you want, by doing a little programming in Arduino. Refer to the DIY site for directions at the SOFTWARE section. But the default is now set to my name, Kit 61, and the second line is the Geiger Counter name, and the version of software that the AT328 chip is running V10.1. The second window will show this:

175 CPM=1 uSv/h Running at 5.24V


The first line refers to the conversion rate of CPM to uSv/hr for your SBM-20 tube (175) this can be changed either in the program sketch, with Arduino. The second line refers to the current voltage that your system is running at. This is a 5 volt system. The 3000mAh 3.7v lipo battery is boosted to 5v with a pololu booster. Everytime you start up your GC (geiger counter) it will show you this so you will always know your current voltage. The third window will show something like this:

Alarm Set ? Now at 200 CPM


At this point, you can hit the Select button to incrementally change the Alarm threshold number. Once you stop hitting the button and wait, it will be set to the current number shown on the screen and will stay there until you change it either again restarting and waiting for this part. You can also chose from units of measurement such as CPM or uSv/h for the Alarm. B. POWER switch controls the power and charging of the unit. Up turns on the unit, Middle turns if off, and Down is for when you charge the unit. When the unit is charging, the RED LED on the lower left side will remain constant RED while charging, and when charging is complete, it will turn off. If you wish to power the unit with the USB in, and bypass the batteries for extended periods. Switch this power button to the middle position, and flip up the switch next to the USB port. This will allow you to power the unit with the USB power and bypass the battery for long periods I suggest using this power source. But you might just find that using the internal battery is enough. C. LIGHT switch controls the Event LED (BLUE) and the LCD Backlight. Up turns on both, Middle turns both off, and Down turns the LED on, and the Backlight off. D. SOUND switch controls the Event speaker. Up for tone mode, Middle for mute, and Down for Standard Click Mode. More on Tone Mode later. E. ALARM switch controls the Alarm LED and Piezo. Up for both on, Middle for both off, and Down for LED only on. This makes for a silent visual alarm. F. NULL This button is used when running the sound in Tone mode. Its basically like a distance sensitive mode where the closer you get to the radiation source, the higher the pitch of the beep will be. Then once you are at a chosen distance, then you can push this button to reset the distance back to zero, and it will then restart a its lowest tone and as it gets closer, again it will raise in pitch. LEDS Right away, you will hear the beeping of the piezo as your 2 SBM-20 GM tubes picks up radiation events. There are three LEDs below the LCD. The Left one is GREEN and is a system status light which comes on when starting up, and when sending data back and forth to your PC. Its basically a system OK light. If the green light ever freezes up, just restart the GC, and it will reset itself. The middle is BLUE which is for radiation events and coincides with the beeping piezo which can be muted with the mute switch. The Right one is RED for the Alarm which will only light up when a set alarm threshold is reached. The piezo for the alarm is located on top of the unit on the right side. OTHER SWITCHES, BUTTONS, PORTS, DIALS NEW- Added 1 new switch to the right side of the unit next to the USB port. LEAVE THIS OFF WHEN NOT USING USB power to run the unit and this MUST be off in order to charge the battery. Flip this up to turn it on. Down when not powering the unit with the USB. A. Starting on the left side top of the GC is the LCD contrast dial. As the LCD is used, it might get to a point for you to readjust the contrast for it. Not a big deal, while the backlight is on, gently take a small screwdriver and turn it to the left or right until it appears to have the best contrast.

B. Below the contrast pot on the same side is the output multi-port used for Geiger Bot (with the included G-Bot cable), and for Geiger Graph and RAD OSX (with the optional USB/FTDI cable) Just plug in the Geiger Bot cable into this with the 3 conductor plug, and the 4 conductor into your iphone or ipad. Or plug the optional 3.5mm to USB cable into the port, and into a USB on your mac or PC, then follow instructions to run those programs. It also serves as an mono audio output for silent listening with headphones, or with the included 3 conductor to 3 conductor M-M audio cable, you can run sound based data logging software. C. On the right side of the GC is the Mini USB FTDI output/input for programming in Arduino. This also is used to charge the internal Lithium Ion battery (with the power switch in the bottom position.) Or it can be used to power the GC for extended periods, however when you power it this way, I would advise to turn off the LCD backlight. But its ok to turn it on once in a while, but I wouldnt leave it on for extended periods. When uploading any new changes to the program sketch, you will need to have this switch in the up position white it is plugged into your pc with the USB cable. DISPLAY BAR GRAPH: The display has a new bar graph style with placeholders and is much more responsive. It now updates 20 times per second. The tone is also updated at this rate when used. Auto-precision - decimals are dropped from the displayed dose rate as it gets larger. Beginning with v10.1 the LOG PERIOD can now be set to intervals of less than 1 minute. Valid settings are OFF, 2s, 3s, 4s, 5s, 6s, 10s, 12s, 15s, 20s, 30s, and 1 minute intervals up to 720 minutes. "Tube Select" is still supported where grounding I/O pin 9 will use an alternate ratio for CPM to Dose unit. The CPM>DOSE RATIO in the menu will set and save which ever ratio is selected at the time it's used. This allows setting of both the primary and alternate ratios. ABOUT DOSE UNITS: The menu allows you select the name of the dose unit that appears on the display. However, to be clear, there is no built in conversion between them. Instead the CPM->[DOSE] RATIO is adjusted depending on the name of the DOSE UNIT selected. For example, 175.43 is the default set for the SBM-20 with uSv as the dose unit. Suppose you pick "mR" as the dose unit name, and want to measure in milirems. ("mR" more correctly abbreviates as milliroentgens but is used to save display space.) The rem is defined as .01 seivert. Therefore, to use the same ratio that was designed for the tube, you would multiply that ratio by 10. You would enter a CPM->[DOSE] RATIO as 175.43 x 10 or 1754.3. Likewise if you wanted microrems ("uR") you would divide the ratio by 10 and enter 17.54. If you do want to use roentgens (used in older instruments) this source states that they are .96 rem in soft tissue. So the CPM->[DOSE] RATIO for actual mR would be 175.43 x 10 x .96 or 1684.1. (for uR it would be 16.84) PLEASE REFER TO THE DIY GEIGER COUNTER DEVELOPERS WEBSITE FOR FURTHER INFORMATION:

http://www.sites.google.com/site/diygeigercounter/ ARDUINO Software and Serial-USB connection information:


ON the cd you will find the FTDI driver and Arduino program version 1. Install both and restart your mac. Copy the Geiger Sketch folder to the same folder as your Arduino program is and remember where that is as that will be where you go to save your sketch everytime you make a change to it. There will also be a Library folder that will also need to be in the same folder. Just remember that the folder has to be the same exact name as the sketch name is. And also within Arduino, you will have to go to preferences and show Arduino where your default sketch folder is. ARDUINO SETTINGS: Brohogan Software system version 10.1 1. Open Arduino 2. Open the saved sketch .ino file, connect your Geiger counter to the USB with power switch off. 3. Verify the file by clicking the little check mark icon. 4. Click TOOLS, and Select Board type as Arduino UNO, and select serial port as the top tty choice. 5. Click Serial Monitor (top right looking glass icon). Set Baud rate to 9600 and you should see the CPM, uSv and geiger counter voltage data coming up once per minute. For more info go to website under Software section on the DIY geiger counter website. Or go to Arduino.cc GEIGER BOT SUGGESTED SETTINGS: (You may have to play with it to get it just right) GO TO: https://sites.google.com/site/geigerbot/

Select options

Select Geiger Counter

Select LND712 CS137

Adjust Conversion factor to your tube: 123 for LND712 175 for SBM-20 360 for LND7317 Select I/O Settings

Auto Adjust OFF (you may need to play with this setting) RMS Window 1 Delay Window 30 Volume Thresh 20000

Ultrafast Rates ON

OTHER SOFTWARE LINKS: http://www.blackcatsystems.com/GM/download.html http://www.imagesco.com/geiger/geiger-graph.html


GEIGER GRAPH FOR PC NETWORKS: (cost is around $60. Use the OPTIONAL FTDI 3.5mm to USB cable) This is a PC only software.

HARDWARE 1. DIY Geiger counter kit V5.1 by Brohogan, Running operating system 10.1 2. (2) SBM-20 Geiger Muller Tubes 3. Power System by Seeeduino, Sparkfun and Pololu (please charge the unit until the RED light goes out) A. You can power the Geiger in a couple different ways 1. With internal Lipo battery (Power switch in UP position) 2. With PWR switch OFF (middle), USB cable plugged into USB port on RIGHT side of geiger, USB PWR switch on right side of unit switched UP, then plug USB cable into: a. Computer or laptop USB b. Wall charger block (included) c. Standard 5v USB Cigarette adapter d. To power and operate the unit this way for long periods, TURN OFF BACKLIGHT
POWER and OTHER SYSTEM ITEMS: This system is capable of producing 900+ volts, so be careful or you may get zapped when handling the system while it is powered on. A. Seeeduino Lithium Ion battery - 3.7v 3000mAh http://www.seeedstudio.com/depot/lithium-ion-polymer-battery-pack-3a-p-588.html?cPath=178_183 Full recharge in 3 hours, provides approximately 40 hour constant use of geiger counter with backlight off. Charge with PC/USB will take about 5 hours or more. B. USB Lithium Polymer battery charger https://www.sparkfun.com/products/10401 C. Pololu 5V Step-Up/Step-Down Voltage Regulator S7V7F5 http://www.pololu.com/catalog/product/2119 D. Sparkfun 5V FTDI Basic Breakout https://www.sparkfun.com/products/9716 ENCLOSURE Dimensions: New Age Enclosure - S784114 - 7.8" x 4.1" x 1.4" (not including handle or feet) http://www.newageenclosures.com/files/784114_r5_2.pdf REPAIRS: If the unit fails for some reason with a year from purchase, I will be more than happy to do any maintenance you need at no charge except shipping. PACKAGE CONTENTS: In your package you will find: Geiger Counter, (3) Cables: Geiger bot 3 to 4 conductor, Audio 3 to 3 conductor, Mini USB to standard USB2 with wall charger. CD with software and documents, Manual, RAD sticker, and extra faceplate labels. Rad samples upon request provided in micro lead pig.

SBM-20
HARD BETA and GAMMA GM DETECTOR Specifications
GENERAL Gas Filling Cathode Material Maximum Length (mm) Effective Length (mm) Maximum Diameter (mm) Effective Diameter (mm) Connector Operating Temperature Range 0C WALL Areal Density (mg/cm2) Thickness (mm) Ne + Br2 + Ar Stainless Steel, 50 mkm 108 91.0 11 10 Pin -60 to +70 ELECTRICAL Minimum Anode Resistor (meg ohm) Recommended Anode Resistor (meg ohm) Recommended Operating Voltage (volts) Operating Voltage Range (volts) Initial voltage (volts) Plateau length (volts) Maximum Plateau Slope (%/100 volts) Minimum Dead Time (at U=400V, micro sec) Working range (mkR/s) Working range (mR/h) Gamma Sensitivity Ra226 (cps/mR/hr) Gamma Sensitivity Co60 (cps/mR/hr) Inherent counter background (cps) Tube Capacitance (pf) Life (pulses) Weight (grams) 1.0 5.1 400 350 - 475 260 - 320 at least 100 10 190 0.004 - 40 0.014 - 144 29 22 1 4.2 at least 2*1010 10

40 0.05

SELECT
ALARM SCALER

POWER
ON/PC OFF CHARGE

LIGHT
ON/ON OFF ON/OFF

ALARM
ON/ON OFF ON/OFF

SOUND
TONE OFF CLICK

NULL
TONE RESET

HIRO+plus

A A s U LT R

SBM-20x2

RADIATION DETECTOR

atomic.dave

EN

SITIV E

BE
A TA s G

BRD FTDI 5V
1 3 5 6 4 2 1 3 5

5V Boost IN
2 4 6
1 3 5 6 4 2

Blue LED POS LED BRD POS Blue LED POS OPEN S Red LED POS OPEN OPEN Piezo Jum mp B Jump LCD Jump L BRD Pin 15 5 BRD Pin 15 OPEN

LCD Jump R

S Red LED POS

Alarm Piezo POS OPEN

Board Pin n 12

FTDI 5V

LIPO Chrg 5V Out

Jump Piezo Jum mp A

LIPO Chrg USB POS

OPEN

A
LIGHT NULL
TONE Reset
E VEN NT EVENT LED LE ED
270 OHM RESISTOR RESISTOR
1 3 5 6 5 6 5 6
SELECT
ALARM SCALER

B F
1 2

C
ALARM
AL ARM ALARM LED
300 OHM RESISTOR RESISTOR
1 3 4 ALARM PIEZO PIEZO 2

D
SOUND
SPEAKER TONE OFF CLICK LED/SND ON/ON OFF ON/OFF

E
+
1 2 4
POWER
ON/PC OFF CHARGE

SELECT
LED/BKL LT LED/BKLT ON/ON OFF ON/OFF
2 4

POWER P

ALARM Threshold Timer T imer

PWR/CHG P O ON/PC O OFF C CHARGE

_
3

LIGHT
ON/ON OFF ON/OFF

ALARM
ON/ON OFF ON/OFF

SOUND
TONE OFF CLICK

NULL
TONE RESET

LCD Diode Voltage V oltage Limiter Band to left

HIR HIRO+plus

LIPO LIP CHA CHARGER

LIPO FTDI

O ON

USB Power Power


O OFF

MUL LT TI-SOFTWARE A MULTI-SOFTWARE OUTPUT PORT OUTPUT


3.5mm Socket Socket
O 56K OHM ap Cap RESIS STOR .1 uF C RESISTOR

.1 uF F Cap Cap 1K OHM RESISTOR RESISTOR


7 6 5 4 3 2

L R
8 9 10 11 12 13

14 15 16 17 18 19

_ +
5V Up/Do wn Up/Down BOOST ST TAT TUS STATUS LED

In

680 OHM RESISTOR RESISTOR

O ut Out